Anda di halaman 1dari 2

T

h
e

i
n
f
o
r
m
a
t
i
o
n

p
r
o
v
i
d
e
d

i
n

t
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

c
o
n
t
a
i
n
s

g
e
n
e
r
a
l

d
e
s
c
r
i
p
t
i
o
n
s

a
n
d
/
o
r

t
e
c
h
n
i
c
a
l

c
h
a
r
a
c
t
e
r
i
s
t
i
c
s

o
f

t
h
e

p
e
r
f
o
r
m
a
n
c
e

o
f

t
h
e

p
r
o
d
u
c
t
s

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
T
h
i
s

d
o
c
u
m
e
n
t
a
t
i
o
n

i
s

n
o
t

i
n
t
e
n
d
e
d

a
s

a

s
u
b
s
t
i
t
u
t
e

f
o
r

a
n
d

i
s

n
o
t

t
o

b
e

u
s
e
d

f
o
r

d
e
t
e
r
m
i
n
i
n
g

s
u
i
t
a
b
i
l
i
t
y

o
r

r
e
l
i
a
b
i
l
i
t
y

o
f

t
h
e
s
e

p
r
o
d
u
c
t
s

f
o
r

s
p
e
c
i
f
i
c

u
s
e
r

a
p
p
l
i
c
a
t
i
o
n
s
.
I
t

i
s

t
h
e

d
u
t
y

o
f

a
n
y

s
u
c
h

u
s
e
r

o
r

i
n
t
e
g
r
a
t
o
r

t
o

p
e
r
f
o
r
m

t
h
e

a
p
p
r
o
p
r
i
a
t
e

a
n
d

c
o
m
p
l
e
t
e

r
i
s
k

a
n
a
l
y
s
i
s
,

e
v
a
l
u
a
t
i
o
n

a
n
d

t
e
s
t
i
n
g

o
f

t
h
e

p
r
o
d
u
c
t
s

w
i
t
h

r
e
s
p
e
c
t

t
o

t
h
e

r
e
l
e
v
a
n
t

s
p
e
c
i
f
i
c

a
p
p
l
i
c
a
t
i
o
n

o
r

u
s
e

t
h
e
r
e
o
f
.
N
e
i
t
h
e
r

S
c
h
n
e
i
d
e
r

E
l
e
c
t
r
i
c

I
n
d
u
s
t
r
i
e
s

S
A
S

n
o
r

a
n
y

o
f

i
t
s

a
f
f
i
l
i
a
t
e
s

o
r

s
u
b
s
i
d
i
a
r
i
e
s

s
h
a
l
l

b
e

r
e
s
p
o
n
s
i
b
l
e

o
r

l
i
a
b
l
e

f
o
r

m
i
s
u
s
e

o
f

t
h
e

i
n
f
o
r
m
a
t
i
o
n

c
o
n
t
a
i
n
e
d

h
e
r
e
i
n
.
May 12, 2014
1
Product data sheet
Characteristics
M7650A0C0B6E0A0E
M7650 energy meter - 5 mB - 256 samples - 5
A - 60 Hz - Ethernet
Main
Range of product PowerLogic
Device short name ION7650
Product or component
type
Energy and power quality meter
Complementary
Power quality analysis Voltage sag and swell detection
Dip and swell, transient
Compliance monitoring
Waveform capture
Setpoint learning
Harmonic distortion
Programmablity (logic and math functions)
EN 50160 compliance checking
Disturbance direction detection
IEC61000-4-30 class A measurements
Device application Tariff metering
Co-generation and IPP monitoring
Demand and power factor control
Load curtailment
Equipment monitoring and control
Energy pulsing and totalisation
Instrument transformer correction
Type of measurement Reactive power per phase
Reactive power total
Active power per phase
Active power total
Apparent power per phase
Apparent power total
Power factor per phase
Power factor total
Frequency
Voltage
Current
Supply voltage 110...300 V DC
85...240 V AC 47...63 Hz
Network frequency 60 Hz
Power consumption in VA 0...35 VA
Display type Backlit LCD
Sampling rate 512 samples/cycle
Measurement current 5 A
Input type Current 0.005...20 A 0.002 Ohm
Measurement voltage 57...347 V AC phase to neutral
100...600 V AC phase to phase
Number of inputs 4 analog 0...20 mA
16 digital 120 V DC
Measurement accuracy 0.1 % voltage 57...288 V
0.1 % current 1...5 A
0.2 % energy
Accuracy class Class 0.2S energy
2
Number of outputs 4 solid state
3 relay
Communication port protocol DNP3
IEC 61850
Modbus
TCP/IP
Telnet
ION
Communication port support Modem RJ11
Ethernet RJ45
Fiber optic ST
RS485
RS232 SUB-D 9
Data recording Data logs
Event logs
Min/Max of instantaneous values
Sequence of event recording
Time stamping
Trending/Forecasting
GPS synchronisation
Memory capacity 5 MB
Environment
Electromagnetic compatibility Conducted and radiated emissions B CISPR 22
1.2/50 s shock waves immunity test IEC 61000-4-5
Electrical fast transient/burst immunity test IEC 61000-4-4
Susceptibility to electromagnetic fields IEC 61000-4-3
Electrostatic discharge immunity test IEC 61000-4-2
Mounting mode Flush-mounted
Type of installation Indoor installation
Overvoltage category III
IP degree of protection IP50 front face IEC 60529
IP30 back IEC 60529
Relative humidity 5...95 %
Pollution degree 2
Ambient air temperature for operation -20...70 C
Ambient air temperature for storage -40...85 C
Operating altitude 0...2000 m
Standards IEC 61010-1
Width 192 mm
Depth 174 mm
Height 192 mm
Product weight 1.9 kg

Anda mungkin juga menyukai