Anda di halaman 1dari 20

= 220 psia

= 6.56 ft Konversi
= 0.000191 psia 1 Barrel =
= 64.3 lb/ft3 1 Barrel =
= 60 cp 1 Gallon =
0.0402 lb/ft s 1 Liter
= 77.56 F
=
Nilai
10
Specific Gravity
Data
1.03
Perhitungan Flow Rate
Flow Rate
P = Tekanan
h = Tinggi
Vapor Pressure
Density
Vicosity
Temperature
31.5 Gallon
119.2405 Liter
3.785412 Liter
0.176573 ft3
Satuan Nilai Satuan
LPH = 240 LPD
= 0.0839 BPH
= 2.0127 BPD
= 0.0440 GPM
= 4.905E-04 ft3/s
Perhitungan Flow Rate
Flow Rate
V 0.048306 ft/s
Q 2.012739 barrel/day
d 0.5 inch (inside diameter)
qf 0.00049 ft3/s
64.3 lb/ft3
ID optimum 0.217226 in
Re 38.63258
p 64.3 lb/ft3
d 0.5 ft (inside diameter)
V 0.048306 ft/s
0.0402 lb/ft s
P 0.000307 psi/100ft
f 0.002 Figure 2.3 (Friction Factor Chart)
Q 2.012739 barrel/day
Pressure Drop
LINE SIZING WITH API RP 14E
Sizing For Liquid lines
Liquid Flow Velocity (ft/s) Optimum Inside Diameter
Reynold Number
Turbulent
S 1.03 (Specific Gravity)
d 0.5 inch (inside diameter)
qf 0.00049 ft3/s
60 cp
ID optimum 0.403471 in
Viscous (Kental)
Optimum Inside Diameter
Turbulent
1. Bila Tangki yang dipakai Tangki Terbuka, maka :
hp = 34 ft
2. Bila Tangki yang dipakai Tangki Tertutup, maka :
Dik : psia
hp = 0.0000 ft
hp 34 ft
Vapor Pressure 0.000191 psia
hvpa 0.000428 ft
ha = = 3.1075 ft
Keterangan
L = panjang pipa actual (ft) = 10 ft
Vi = Laju alir di suction (ft/s) = 0.048306 ft/s
Rp = Pump Speed (rpm) = 1450 rpm
C = Konstanta Pompa
0.2 Simplex double acting
0.2 Duplex single acting
NPSHA Calculator
hp yg terpakai
Tekanan Absolut Pump (hp)
Vapor Pressure Head (hvpa)
Acceleration Head (ha)
L x Vi x Rp x C
K x G
h = suction lift
P
P
NPSHA = hp + hst - hf - hvpa - ha
0.115 Duplex double acting
0.066 Triplex single or double acting
0.46 Quintuplex single or double acting
0.28 Septuplex single or double acting
K = Konstanta Theoritical Acceleration Head
1.4 Liquid (Nilai Compresibility hampir tidak ada)
1.5 Amine, Glycol, Water
2 Most Hydrocarbon
2.5 Compressible liquid (Hot oil or Ethane)
G = Konstanta gravitasi
32.2 (ft/s2)
Equivalent Lenght (Tergantung ID pipa)
ft m
0
0
0
0
0
0
0
0
0
0
0
Ukuran
Type Jumlah Total
Untuk Menghitung Panjang Pipa Actual
Velocity (Laju Alir) 0.04830575 ft/s
32.17 ft/s2
0.0000 ft
0.00030711 psia 0.0006878 ft
Jenis K Hasil (ft) Jumlah Total (ft)
Regular 90 Flanged 0.3 0.0000 0
Regular 90 Threaded 1.5 0.0001 0
Long Radius 90 Flanged 0.2 0.0000 0
Long Radius 90 Threaded 0.7 0.0000 0
Regular 45 Threaded 0.2 0.0000 0
Long Radius 45 Threaded 0.4 0.0000 0
Return Bend Flanged 0.2 0.0000 0
Return Bend Threaded 1.5 0.0001 0
Line Flow Flanged 0.2 0.0000 0
Line Flow Threaded 0.9 0.0000 4 0.0001306
Branch Flow Flanged 1 0.0000 0
Branch Flow Threaded 2 0.0001 0
Union Threaded 0.08 0.0000 0
Globe (Full Open) 10 0.0004 0
Angle (Full Open) 2 0.0001 0
Pressure Drop
Elbow
Tees
Valve
Return Bend
Friction Head (hf)
Velocity Head
gravity
Pressure Drop Pipe
h
Gate (Full Open) 0.15 0.0000 0
Gate (1/4 Closed) 0.26 0.0000 0
Gate (1/2 Closed) 2.1 0.0001 0
Gate (3/4 Closed) 14 0.0005 0
Swing Check (Forward Flow) 2 0.0001 0
Swing Check (Backward Flow) 2 0.0001 0
Ball (Full Open) 0.05 0.0000 6 1.088E-05
Ball (1/3 Closed) 3.3 0.0001 0
Ball (2/3 Closed) 210 0.0076 0
Strainer 2.9 0.0001 1 0.0001052
Venturi 1.1 0.0000 0
Butterfly 1 0.0000 0
Friction Head (hf) 0.000688 ft
NPSH Available 37.4514 ft
11.4152 m
Result
Total
Tinggi (Antara Permukaan Cairan dengan Center Pompa)
hst 6.56 ft
NB
Posisi Pompa diatas Tangki, maka Nilai Static Head = +
Posisi Pompa dibawah Tangki, maka Nilai Static Head = -
Static Head (hst)
Flow 0.044029 GPM
Tekanan 220 psia
WHP 5.651288 HP
Flow 0.044029 GPM
Tekanan 220 psia
Efficiency 0.8
BHP 7.06411 HP
Menghitung Hydraulic Horse Power
Menghitung Brake Horse Power