0 penilaian0% menganggap dokumen ini bermanfaat (0 suara)
54 tayangan2 halaman
FastNet RTU data Concentrator and SCADA RTU Automation solutions for utility application Easy configuration Robust and compact design DNP3, IEC 60870-5-104, ieee 60870/5-101, Modbus Expandable I / o 1000 event log port forwarding Telnet support FTP firmware upgrade. Typical 0. To 0. A Power Consumption: Max 7. W. Typical 2. W Processor Type: ColdFire 32-bit Internal RAM / Flash Memory: 64 kB
FastNet RTU data Concentrator and SCADA RTU Automation solutions for utility application Easy configuration Robust and compact design DNP3, IEC 60870-5-104, ieee 60870/5-101, Modbus Expandable I / o 1000 event log port forwarding Telnet support FTP firmware upgrade. Typical 0. To 0. A Power Consumption: Max 7. W. Typical 2. W Processor Type: ColdFire 32-bit Internal RAM / Flash Memory: 64 kB
FastNet RTU data Concentrator and SCADA RTU Automation solutions for utility application Easy configuration Robust and compact design DNP3, IEC 60870-5-104, ieee 60870/5-101, Modbus Expandable I / o 1000 event log port forwarding Telnet support FTP firmware upgrade. Typical 0. To 0. A Power Consumption: Max 7. W. Typical 2. W Processor Type: ColdFire 32-bit Internal RAM / Flash Memory: 64 kB
Automation solutions for utility application Easy conguration Robust and compact design DNP3, IEC 60870-5-104, IEC 60870-5-101, Modbus Expandable I/O 1000 event log Port forwarding Telnet support FTP rmware upgrade Real time clock
FastNet RTU for Real Time Monitoring M 0 0 1 0 8 -B R -E N -1
N e tc o n tro l G ro u p 2 0 1 2 Energy Network Automation Energy Network Automation www.netcontrol.com Technical data Housing Material: Extruded Aluminium Size: (HxWxD) 217 x 146 x 63 mm Weight: 1250 g Temperature Range: -40 ... +60 C Relative Humidity: 0 ... 95% Non Condensing Input Voltage Range: 9 ... 30 VDC Current Consumption: Dependent on Input Voltage. Typical 0.1 to 0.3 A Power Consumption: Max 7.3 W. Typical 2.5 W Processor Type: ColdFire 32-bit Internal RAM/Flash Memory: 64 kB/512 kB External RAM/Flash Memory: 8 MB/4 MB Memory Card (Optional): Minimum size 1 GB Communication Interface 5 RS232 1 R-bus 1 RS485 1 Ethernet Protocols: IEC 60870-5-101 IEC 60870-5-104 DNP3 Modbus RTU Isolation: Ethernet to GND 1.5 kV RS485 to GND 1.5 kV Compliances Radiated Disturbance: EN 55022:1998, -A1:2000, -A2:2003 Class B Electrostatic Discharge: EN 61000-4-2:1995 Radio-frequency Electro Magnetic Field: EN 61000-4-3:1997 Fast Transients: EN 61000-4-4:1995 Induced Radio-frequency Field: EN 61000-4-6:1996 Power Frequency Magnetic Field: EN 61000-4-8:1994 Inputs & Outputs Number of Analogue Inputs: 8 Input Range: -10 ... +10 V 0 ... 10 V 0 ... 20 mA -5 ... +5 V -20 ... +20 V possible on request Isolation: 2.5 kV Number of Digital Inputs: 18, expandable up to 178 DIs Voltage Input Range: 9 ... 70 VDC Optical Isolation: 4 kV Input Impedance: 10 k Functions: Pulse Counting, On Delay Time/Off Delay Time, Double Indication Filtering, Time Stamp Number of Digital Outputs: 14, expandable up to 174 DOs Outputs 1 to 10 Max Rated Current: 2 A Voltage: 125 VAC, 60 VDC Power Resistive: 62.5 VA, 30 W Isolation: 1.0 kV Outputs 11 to 14 Max Rated Current: 3 A Voltage: 250 VAC, 130 VDC Power Resistive: 50 VA, 60 W Power Inductive: 25 VA, 30 W Isolation: 1.0 kV (1.5 kV if select before execute) Interfaces The FastNet base unit supports: 18 digital inputs 14 digital outputs 8 analogue inputs 1 Ethernet port 5 RS232 ports 1 RS485 port 1 R-Bus expansion port 9 ... 30 VDC supply
The physical connection of these inputs and outputs is via removable screw terminal connectors, making isolation and removal of a FastNet RTU very simple and quick. Digital Outputs The digital outputs are exible and can be assigned individually or as paired outputs. The unit also fully supports select before execute output function, allowing additional control security. This feature is an option, so that it can be disabled if the user wishes to keep the communication to the units to a minimum, such as when a narrow band communication system is deployed. The digital outputs are fully congurable and support both pulse and toggle options, and the pulse times are individually user congurable. Digital Inputs Digital inputs can also be assigned individually or in pairs and have a programmable debounce or delay time. When as- signed as a pair, the on and off delay times can be cong- ured in order to avoid unwanted state changes. The RTU will not transmit the unknown circuit breaker which has a certain amount of travel time between opened and closed positions. The digital inputs also support chatter control which prevents an input from permanently sending changes of state, if connected to faulty equipment which is changing its value constantly. This feature is very useful in preventing one RTU from dominating a communication channel. FastNet RTU for Real Time Monitoring FastNet is a compact RTU for electricity transmission and distribution networks, principally for use with distribution automation equipment in the secondary electricity networks. It can also be used as a data concentrator and a primary SCADA RTU. Easy Conguration and Set-up As an option, the FastNet comes supplied with a memory card slot, which can be used to store all of the units conguration parameters. It makes set-up easier as well as replacing units as simple as swapping memory cards from one FastNet to the next. It also means that conguration can be achieved just by bringing the memory card to the site in order to congure the unit, making installation and maintenance easier and more secure. The memory card can also be used to store the event log for the unit, allowing study of sequence of events data. The FastNet RTU can also be congured via Ethernet and incorpo- rates a memory card for easy upgrading. Easy I/O Expansion The FastNet is designed to support either additional extended I/O modules or further daisy-chained FastNet RTUs. One option to increase the number of digital IO is to connect maximum ten RTU-16D cards to the FastNet through R-bus. Each RTU-16D card has 16 digital inputs and 16 digital outputs. It means that the maximum amount of digital inputs is 178 and maximum number of digital outputs is 174. Analogue Inputs The eight analogue inputs are also fully congurable and have programmable sampling times and support for dead-banding in order to reduce data trafc without compromising performance. A dip switch allows the user to set the analogue measurement mode between voltage and current. Inputs can be used for both AC and DC signal inputs. These inputs can also be averaged over congurable time periods if required, and both scaling and offsets can be applied to the values. Flexible Communication Solution The FastNet supports both polled and event-triggered communication sometimes referred to as report-by-exception communication. Since both modes are supported it is usual that a background health poll routine is supplemented with event triggered communication. Individual inputs can have a different class assigned to them depending on whether they are to be detected only during health poll or as a triggered event. The FastNet supports a number of communication connection options. It has one RS485 connection, ve RS232 ports while an RJ45 port provides Ethernet connection. There is one RS232 port that is reserved for service and support and another for programming on the front panel. Port forwarding is available on all communication ports. Modbus Master FastNet can act as a Modbus RTU master for other RTUs acting as Modbus RTU slaves. Energy Network Automation FastNet RTU FastNet RTU Digital Outputs Analogue Inputs Digital Inputs Conguration port MP LED indication for each Input & Output 16DI 16DI 16DO Modbus Expansion SCADA Port IEC 60870-5-101 IEC 60870-5-104 DNP3 Modbus FastNet Expansion Port Diagram 16DI 16DO 16DO Ground Voltage connection RS485 R-bus expansion port Memory card LEDs indicating Tx and Rx RS232 F Dipswitch LEDs indicating Tx and Rx RS232 M Ethernet 16DO 16DO 16DO 16DO 16DO 16DO 16DO 16DI 16DI 16DI 16DI 16DI 16DI 16DI