0 penilaian0% menganggap dokumen ini bermanfaat (0 suara)
174 tayangan1 halaman
This document summarizes the configuration of a 650 series protection relay for a 132kV substation in India. The configuration includes functions for transformer protection, overcurrent protection, voltage and frequency protection, and monitoring. The hardware configuration includes an analog module for current and voltage inputs, binary input/output modules, and a communication module.
This document summarizes the configuration of a 650 series protection relay for a 132kV substation in India. The configuration includes functions for transformer protection, overcurrent protection, voltage and frequency protection, and monitoring. The hardware configuration includes an analog module for current and voltage inputs, binary input/output modules, and a communication module.
This document summarizes the configuration of a 650 series protection relay for a 132kV substation in India. The configuration includes functions for transformer protection, overcurrent protection, voltage and frequency protection, and monitoring. The hardware configuration includes an analog module for current and voltage inputs, binary input/output modules, and a communication module.
Tender ID: 14Q2269565 Pos: 10 Cancel < Back Print thi s page Save pri ce and confi guration Country of End User IN End User - Utili ty Shankar Ratna Sugar Ltd Station Name Sholapur Voltage Level - kV 132kV IED code : RET650*1.1- A01AX00-X00- B1A6- BE- RA-CX0- RA2- AAXX- B Product description : Transformer protection, RET650,A01A,Single breaker, 2 winding BASIC FUNCTIONS for configuration alternative A01A 1Ph High impedance differential protection (HZPDIF,87),2pcs Automatic voltage control for tapchanger, parallel control (TR8ATCC,90),1pcs Bay control (QCBAY),1pcs Breaker close/trip circuit monitoring (TCSSCBR),3pcs Breaker failure protection, 3-phase activation and output (CCRBRF,50BF),2pcs Circuit breaker condition monitoring (SSCBR),2pcs Configurable logic blocks ( ),1pcs Directional Over-power protection (GOPPDOP,32),1pcs Directional Under- power protection (GUPPDUP,37),1pcs Disturbance report (DRPRDRE),1pcs Four step phase overcurrent protection (OC4PTOC,51_67),2pcs Four step residual overcurrent protection (EF4PTOC,51N_67N),2pcs Function block for service values presentation of the analog inputs (AI SVBAS),1pcs Function for energy calculation and demand handling (ETPMMTR),3pcs Handling of LR-switch positions (LOCREM),1pcs I nstantaneous phase overcurrent protection, 3-phase output (PHPI OC,50),2pcs I nstantaneous residual overcurrent protection (EFPI OC,50N),2pcs I nsulation gas monitoring function (SSI MG,63),2pcs I nsulation Liquid monitoring function (SSI ML,71),2pcs LHMI control of PSTO (LOCREMCTRL),1pcs Measurements,1pcs Negative sequence based overcurrent function (DNSPTOC,46),1pcs Overexcitation protection (OEXPVPH,24),1pcs Overfrequency protection (SAPTOF,81),4pcs Pole discordance protection (CCRPLD,52PD),2pcs Rate- of-change frequency protection (SAPFRC,81),2pcs Restricted earth fault protection, low impedance (REFPDI F,87N),2pcs Station battery supervision (SPVNZBAT),1pcs Tap changer control and supervision, 6 binary inputs (TCMYLTC,84),1pcs Thermal overload protection, two time constants (TRPTTR,49),2pcs Transformer differential protection, two winding (T2WPDI F,87T),1pcs Tripping logic, common 3-phase output (SMPPTRC,94),2pcs Two step overvoltage protection (OV2PTOV,59),1pcs Two step residual overvoltage protection (ROV2PTOV,59N),1pcs Two step undervoltage protection (UV2PTUV,27),1pcs Underfrequency protection (SAPTUF,81),4pcs ACT CONFIGURATION ABB Standard configuration, X00 FUNCTION PACKAGES Software options No software options, X00 First HMI Language HMI language, English I EC, B1 Additional HMI language HMI language, English US, A6 HARDWARE Casing Rack, 6U 1/2x19 inch, max 4 I/ O+1 TRM or max 2 I / O+1 TRM and 1 AI M, B Back plane module, pBPM - basic BPM, 6U 1/2 x 19" Mounting details Flush mounting kit , 6U 1/2x19 inch case, E Connection type for power supply, I nput/ Output and communication modules, pCONI O Ringlug terminals, R Power supply, pPSM PSM03, 100- 240V AC, 110-250V DC, 9BO, A Human machine interface, pHMI LHMI , OL4000, ANSI 6U 1/2 x 19", Basic, C Detached LHMI No detached mounting of LHMI, X0 Connection type for analog modules, pCONAI Ringlug terminals, R Analog system slot P2/ X101,X102 TRM, 8I + 2U, 1/ 5A, 100/220V, A2 Binary input/output module slot P3/X321,X324 BI O01, 9 BI , 3 NO Trip, 5 NO Signal, 1 CO Signal, A Binary input/output module slot P4/X326,X329 BI O01, 9 BI , 3 NO Trip, 5 NO Signal, 1 CO Signal, A Binary input/output module slot P5/X331,X334 No board in this slot, X Binary input/output module slot P6/X336,X339 No board in this slot, X Communication and processing module, pCOM CPM, 14 BI , I RI G-B, Ethernet, LC optical, ST connector, B User Documentation I ED Connect, containing user documentation PRODUCT INFORMATION Data sheet - Product Guide, RET650 ANSI Ver.1.1 ABB ltd Substation Automation Products http://www.abb.com/substationautomation Cancel < Back Print thi s page Save pri ce and confi guration Page1 of 1 5/8/2014 https://de-s-0145532.de.abb.com/servlet/acedispatcher