Entwurf 6.9.04
Movitec VE
Movitec V
Movitec LHS
Fields of Application
Movitec VE are employed for general water supply, sprinkling, irrigation and pressure boosting duties, for warm water and cooling
water recirculation. They are installed in domestic water supply
systems, washing plants, water treatment and fire-fighting systems.
Movitec V(S) and LHS are employed for general water supply,
sprinkling, irrigation and pressure boosting duties, for warm water,
hot water and cooling water recirculation, and condensate transport. They are installed in boiler feed circuits, domestic water supply systems, washing plants, water treatment and filter systems.
They are used for degreaser baths/alkaline cleaning baths, alkalines and oils/emulsions, as well as for fire-fighting, reverse osmosis and surface treatment applications.
Design
Multi-stage, vertical (horizontal installation on request) high-pressure centrifugal pumps, with suction and discharge nozzles of
identical nominal diameters arranged opposite to each other (inline design).
Materials
Standard variants:
VE, V:
All hydraulic components are made of stainless steel
AISI 304
VS, LHS: All hydraulic components are made of stainless steel
AISI 316
Bearings
Designation
Type-series
Pump size
Number of stages
Material variants:
Flange variants/connections:
Movitec VE
Capacities
Heads
Operating pressures
Operating temperatures
Movitec V(S)
Shaft Seal
Movitec LHS
6 - 10
Operating Data
Capacities
Heads
Operating pressures
Operating temperatures
Drive
E S F 4 - 3
Movitec LHS
All V, VS and LHS pumps are supplied with tungsten carbide plain
bearing at the hydraulic rotor.
Movitec VE is supplied without bearing at the hydraulic rotor.
Single-acting, uncooled mechanical seal in accordance with
EN 12756.
Movitec V
Type-series
Movitec V
Movitec VE (close-coupled design)
Material variant
Flange variant
Pump size
Number of stages
Capacities
Heads
Operating pressures
Operating temperatures
1)
Q
H
pd
t
Q
H
pd
t
Q
H
pd
t
The sum of inlet pressure and head at zero flow point must not exceed the value stated.
Conformity Marks
60 Hz
Selection Charts
n [ 3500 1/min
n [ 1750 1/min
Movitec
60 Hz
Movitec
Materials
Part No.
Material
Movitec VE
Movitec V
Movitec VS
1.4308
1.4301
1.4401
Movitec LHS
101
Pump casing
108
Stage casing
160
Cover
171
Diffuser
10-6
Pump shroud
1.4301
1.4404
210
Shaft
1.4305
1.4401
230
Impeller
1.4301
1.4404
341
Motor stool
412
O-ring
EPDM
VITON
525
Spacer sleeve
1.4301
1.4404
529
Bearing sleeve
Bearing
1)
1)
Description
890
Baseplate
905
Tie bolt
920
Nut
932
Circlip
1.4301
1.4301
-
1.4408
1.4404
1.4404
1.4301
1.4404
JL 1040
1.4408
Tungsten-carbide
Ceramic
JL 1040
1.4057
1.4301
1.4404
1.4571
Legend of materials
Description
Standard
to ASTM
Cast iron
JL1040 / GJL-250
EN 1561
A48:40B
1.4301 / X5CrNi18-10
EN 10088
A276:304
EN 10088
A276:316L
1.4408 / GX5CrNiMo19-11-2
EN 10213
A743CF8M
1.4571 / X6CrNiMoTi17-12-2
EN 10088
A276:316
1.4057+QT800 /
X17CrNi16-2- QT800
EN 10088-3
A276:431
EN 10088
A276:303
EN 10088
A276:316
EN 10283
A743:CF8
Please note: The indication of the material designations to ASTM / AISI is not binding.
60 Hz
Movitec
Material Codes
Mechanical seal
Description
Code letter to
EN 12756
Q1
U3
B
U3
E
V
X4
Material
Spring
CrNiMo steel
CrNiMo steel
Q1BEGG
Q1BVGG
U3U3X4GG
U3U3VGG
U3BVGG
Silicon carbide/Carbon/EPDM
Silicon carbide/Carbon/Viton
Tungsten carbide/Tungsten carbide/HNBR
Tungsten carbide/Tungsten carbide/Viton
Tungsten carbide/Carbon/Viton
(40 bar seal; only for Movitec LHS)
Spring-loaded ring
Seat ring
Elastomer
Code number
13
14
15
16
17
Flange
g variant /
C
ti
Connection
Material variant
Max. operating
p
g
pressure ps 1)
15 _C to + 60 _C
VE
= thread
Movitec VE
up to 10 bar
standard
13
optional
-
15 _C to + 120 _C
= oval flange
Movitec V
Movitec VS
up to 16 bar
up to 16 bar
13
14
14, 15, 16
13, 15, 16
15 _C to + 120 _C
VF
= round flange 2)
Movitec VF
Movitec VSF
16 up to 25 bar
16 up to 25 bar
13
14
14, 15, 16
13, 15, 16
15 _C to + 120 _C
Movitec VV
Movitec VSV
up to 25 bar
up to 25 bar
13
14
14, 15, 16
13, 15, 16
15 _C to + 120 _C
Movitec LHS
up to 40 bar
17
1)
2)
3)
The sum of inlet pressure and head at zero flow point must not exceed the value stated.
Drilled to EN 1092-2 PN 25 (optional ASME B 16.1 Class 250 or JIS B2238 16K)
Subject to application limits (see List of Media Handled)
60 Hz
Movitec
Integrated
non-return valve
Corrosion-resistant:
hydraulic parts and pump
shroud of high-alloy stainless steel
60 Hz
Movitec
Corrosion-resistant:
hydraulic parts and pump
shroud of high-alloy stainless
steel
variant Movitec V features a
pump of CrNi steelplate
variant Movitec VS features a
pump of CrNiMo steelplate
High operating
reliability
ensured by torsionproof pump shroud
no partition lines on
the outside
only 2 seal elements
Simple installation
and piping layout
thanks to in-line design
insusceptible to
outside nozzle
forces and moments
60 Hz
Movitec
Reliable, easy-to-service
shaft seal
standardized mechanical seal
to EN 12756
Corrosion-resistant:
hydraulic parts and
pump shroud of high-alloy
stainless CrNiMo steelplate
High operating
reliability
ensured by torsion-proof
pump shroud
no partition lines on the outside
only 2 seal elements
60 Hz
Casing
Pump casing with suction and discharge nozzles of identical
nominal diameters arranged opposite to each other (in-line design).
Movitec VE and V(S): stainless steel pump casing and baseplate made of cast iron with powder coating.
Movitec LHS: stainless steel pump casing.
Shaft Seal
The shaft seal is an uncooled, maintenance-free mechanical
seal to EN 12756.
Drive
Standard for V(S) and LHS:
- Electric motor, 50 Hz, air-cooled, 2- and 4-pole, standard
KSB motor with main dimensions to IEC. Other motor makes
subject to prior consultation with KSB,
up to 2.2 kW 220 - 240 V/380 - 420 V,
3 kW and above 380 - 420 V/660 - 725 V,
type of enclosure IP 55,
insulation class F,
up to 4 kW design V18,
5.5 kW and above design V1,
all motors with PTC resistor from 3 kW and up.
Characteristic Curves 2)
The characteristic curves are based on the following principles:
F Tolerances to ISO 9906, Class 2 / Annex A.
F The motors used for the measurements are standard KSB
motors 1).
F The characteristic curves were obtained with deaerated water
at a temperature of 20 _C and a density of 1.0 kg/dm3 1).
F The characteristic curves are valid for a kinematic viscosity
of 1 mm2/s (1 cst) 1).
F A minimum permissible flow must be maintained to prevent
the pump from overheating (see graph).
0.8
Q min [%]
25
20
15
10
5
0
Coating
LHS 6
30
Installation
0.3
0.6
1.2
1.0
2.4
2.2
4.0
4.6
6.1
Minimum flow
Standard:
Pressure test according to EN 809.
Leak test with water.
2
4
10
14
18
24
32
45
65
Direction of rotation:
Clockwise, seen from the drive side (see arrow indicating direction of rotation on the motor stool).
Tests
Qmin in m3/h
Movitec V
Approved variants:
- Explosion-proof motor II 2 G Eexd/Eexe T3/T4,
design V1/V18, make acc. to our choice.
- Motor for 500 V mains voltage, design V1/V18, make acc. to
our choice.
- Motor make acc. to customers choice (upon request).
Movitec VE and V(S): Cast iron motor stool and baseplate with
powder coating.
Movitec V(S): Cast iron slide flanges protected by sheradising
process.
All pumps: Stainless steel parts without any additional protective coating.
Movitec
40
50
60
70
80
90
100
110
120
Temperature [5C]
F Maximum pressure at the discharge nozzle:
10 bar head at zero flow point with thread flange (VE).
16 bar head at zero flow point with oval flange (V).
25 bar head at zero flow point with round flange (VF) and
Victaulic coupling (VSV).
40 bar head at zero flow point with round flange (LHS)
F NPSH
The NPSH values of the individual characteristic curves are
minimum values corresponding to the cavitation limit; they
refer to deaerated water.
A safety allowance of at least 0.5 m must be added when selecting the pump to compensate for measuring inaccuracies
and minor manufacturing deviations. The NPSH curve reflects mean values.
1)
2)
60 Hz
Movitec
Example
Number
of stages
12
7.5 kW / 10 HP
Motor
size
Qmin
Combination of Hydraulics
Movitec VE 2, 4
01
02
03
04
05
06
no. of stages
7
05
6
5
4
05
01
01
01
01
01
05
05
01
06
03
04
05
01
04
01
01
04
01
01
04
01
01
04
01
01
04
Movitec VE 2
Movitec VE 4
3
2
1
60 Hz
Movitec
Combination of Hydraulics
Movitec V 2, 4, 10, 14
01
02
03
04
05
06
no. of casings
26
05
25
24
23
05
01
01
01
02
05
01
02
01
01
05
01
02
01
01
01
01
01
01
01
01
22
21
20
19
18
17
16
15
14
13
12
11
10
9
8
7
6
5
10
01
01
01
01
01
01
01
01
01
05
05
05
01
01
01
01
01
01
01
02
01
01
01
01
01
01
02
05
01
01
01
01
02
01
01
02
01
02
01
02
01
01
02
01
01
01
01
01
01
02
01
02
01
01
01
01
01
05
05
01
05
05
01
01
01
02
01
02
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
05
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
05
05
05
01
01
01
01
01
01
01
01
02
01
02
01
02
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
02
04
02
04
02
04
02
04
02
04
02
04
01
04
01
04
01
04
02
04
02
04
02
04
02
04
02
04
02
04
02
04
02
04
02
04
02
04
02
04
1
1
1
2
2
2
3
3
3
4
4
4
5
5
5
6
6
6
7
7
7
8
8
8
9
9
9
10
10
10
11
11
15
15
18
18
18
20
20
20
23
23
25
25
18
20
06
2
1
Movitec V 14 -
01
01
01
05
01
4
3
05
01
01
05
01
10
13
13
12
14
16
16
16
12
14
16
60 Hz
Movitec
Combination of Hydraulics
Movitec V 18
01
02
04
05
06
no. of casings
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
06
02
04
Movitec V 18 -
05
02
04
05
01
02
04
05
01
01
02
04
05
01
01
01
01
04
05
02
01
01
01
02
04
05
02
01
01
01
01
02
04
05
02
01
01
01
01
01
02
04
05
02
01
01
02
01
01
01
02
04
05
02
01
01
01
01
01
02
01
01
01
01
01
02
04
05
02
01
01
01
02
01
01
01
01
02
01
01
01
01
02
04
14
16
03
02
01
01
01
02
01
01
01
01
02
04
03
02
01
01
02
01
01
01
02
01
01
02
04
03
02
01
01
01
01
02
01
01
01
02
01
01
01
01
02
04
11
11
12
12
05
02
01
01
01
02
01
01
01
02
04
05
02
01
01
01
01
02
01
01
01
01
02
04
10
12
171.01 Diffuser
171.02 Diffuser with ceramic bearing
171.03 Diffuser Upper
108.04 Stage casing bottom
Impeller location
no. of diffusers
17
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
02
04
1
1
1
03
02
04
03
01
02
04
03
01
01
02
04
03
02
01
01
01
04
2
2
2
3
3
3
4
4
4
5
5
5
03
02
01
01
01
02
04
03
02
01
01
01
01
02
04
6
6
6
7
7
7
03
02
01
01
02
01
01
02
04
03
02
01
01
01
02
01
01
02
04
8
8
8
9
9
9
03
02
01
01
02
01
01
01
01
02
04
10
10
10
16
11
60 Hz
Combination of Hydraulics
Movitec VF 65
01
171.01 Diffuser
02
550
no. of diffusers
10
9
8
7
6
5
4
3
2
1
Movitec VF 65 -
01
01
01
02
02
01
01
02
02
01
01
02
01
02
01
01
01
02
01
02
01
01
01
02
01
02
01
01
01
01
02
02
550
02
550
01
550
02
550
01
550
02
550
02
550
02
550
02
550
Movitec LHS 6
01
02
04
05
no. of casings
21
20
19
05
05
02
01
05
02
01
01
01
05
02
02
01
01
01
01
01
01
01
02
05
02
01
01
01
01
01
01
01
01
18
17
16
15
14
13
12
11
10
9
05
02
01
01
01
01
01
01
01
01
01
02
01
02
01
01
01
01
8
7
6
01
01
01
01
02
01
02
01
01
01
01
01
01
01
01
02
01
01
5
4
01
01
01
01
01
01
01
01
01
01
01
01
3
2
1
01
02
04
01
02
04
01
02
04
01
02
04
01
02
04
01
02
04
10
12
14
16
18
20
Movitec LHS 6 -
12
01
02
01
01
02
Movitec
60 Hz
Movitec
433
->
Description
6 and 7
8 and 9
10 and more
%
1 set
2 sets
3 sets
30
1 set
2 sets
3 sets
30
13
60 Hz
Movitec
The data refer to the materials chemical resistance. Relevant regulations / standards for pump applications have to be complied
with.
The actual operating conditions must always be checked (concentration, temperature, solids content).
The penetration of air into the system must be avoided by all means.
If the operating conditions differ from the data given (e.g. mixed products) or if the media are not included in the table below, please
contact KSB.
Basic data:
- Temperature ranges:
D The reference temperature is 20 C.
D In the case of temperatures <0 C, please contact KSB.
D If the temperature exceeds > 50 C, check and observe the fluids vapour pressure.
D Max. temperature = 120 C, unless indicated otherwise.
- Max. concentration = 100 %, unless indicated otherwise.
- Mechanical seal of silicon carbide / carbon (Q1B): not suitable for media containing solids; this rule also covers particles developing as a result of salt crystallization at low fluid temperatures.
- Mechanical seal of tungsten carbide / tungsten carbide (U3U3): solids content max. 20 ppm (depending of particle size), with
the exception of corrosive media. Media with a higher abrasive solids content are as a rule not permitted. (ppm = 1 mg/kg).
- Please note: High temperatures will increase corrosion (reference temperature = 20 C).
- Under unfavorable conditions (increased temperature, deposits, long periods of standstill) chloride contents of more than
300 mg/l may result in local corrosion.
Medium handled
(see special conditions given at the end of
the table)
Alcaline (bottle rinsing) (pH <9,5)
Alcaline (metal degreasing) (pH <9,5)
Alcohol (ethanol)
Alum
Aluminium sulphate
Ammonium chloride (salmiac)
Ammonium sulphate
Antifreeze (glycol base), salt-free
Antifreeze (halogen-free) 4)
Bicarbonate of ammonia
Buttermilk
Butyl alcohol (butanol)
Calcium acetate
Calcium nitrate (non-acidic)
Cider
Citric acid
Copper sulphate
Crude oil condensate 4)
Crude oil 4)
Deionised water (demineralised)
Diesel oil (light, extra-light)
Ethanol (alcohol)
Ethylene glycol/diethylene glycol (salt-free)
Ferric sulphate (II)
Fruit juices pH neutral (6.5)
Fuel oil (light) (without antifreeze for - 20 C
and below)
Glycerin
Glycol (salt-free) (see Ethylene glycol)
Hexan
Isopropyl alcohol (2-propanol)
Kerosene
Lactic acid
Liqueur
Magnesium sulphate
Maleic acid
Miscellaneous 4)
14
Content
max %
max.
10
10
3
5
25
20
min. 20
10
10
10
25
10
Temperature
max in C
max.
80
60
100
80
60
13
V/VE
VS
V1)/VE1)
V/VE
V/VE
V1)/VE1)
V1)/VE1)
V/VE
VS
V1)/VE1)
V1)/VE1)
V/VE
V/VE
-
14
VS
V 1)
V 1)
V 1)
V
V
15
V 1)
V 1)
V 1)
-
16
V 1)
V 1)
V
-
17
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
80
LHS
V/VE
V/VE
V/VE
-
V
V
V 1)
V
V
VS
V 1)
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
80
80
60
80
60
30
60
40
80
60
60
60
40
30
80
80
10
40
40
10
10
100
40
80
100
60
60
80
60
60
60 Hz
Medium handled
(see special conditions given at the end of
the table)
Oil/water mixtures (without solids)
Oils (without abrasive solids):
Corn oil
Cutting oil 4)
Hydraulic oil 4)
Linseed oil
Linseed oil + 3 % H2SO4
Lubricating oil 4)
Mineral oil 4)
Peanut oil
Rapeseed oil
Salad oil 4)
Silicon fluid 4)
Soybean oil
Turpentine oil 4)
Turbine oil (no SDF oils) 4)
Vegetable oils (free from H2SO4) 4)
Paraffin(s) 4)
Petroleum (without solids)
Phosphoric acid
Polyethylene glycol 4)
Polyglycols 4)
Potassium bicarbonate
Potassium carbonate
Potassium hydroxide
Potassium nitrate
Potassium sulphate
Propyl alcohol (see isopropyl alcohol)
Soda lye (see sodium hydroxide)
Sodium carbonate
Sodium hydroxide (soda lye)
Sodium nitrate (non-acidic)
Sodium sulphate (non-acidic)
Spirits
Sulphuric acid
Tannic acid
Tartaric acid
Trisodium phosphate
Turpentine (oil) (see oil; turpentine) 4)
Vinegar (wine vinegar)
Content
max %
max.
Temperature
max in C
max.
100
100
80
60
60
100
80
100
100
60
100
60
100
5
10
25
5
10
3
6
10
10
5
5
20
8
4
10
80
20
80
80
60
60
60
30
20
80
60
60
60
60
60
30
80
60
80
60
60
Movitec
Mechanical seal variant
13
-
14
V
15
-
16
-
17
LHS
V1)3)
V 3)
V 3)
VS
V 3)
V 3)
V 3)
V 3)
V 3)
V 3)
V 1)3)
V 3)
V 3)
V 3)
V
V
V
V
VS
VS 3)
V 1)
V 1)
V
-
V 1)
V 1)
V 1)
V 1)
V 1)
V 1)
-
V 3)
-
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
LHS
-
V/VE
V1)/VE1)
V1)/VE1)
V1)/VE1)
V/VE
VS
15
60 Hz
Medium handled
(see special conditions given at the end of
the table)
Water/glycol mixture (salt-free with inhibitors)
Water:
condensate
cooling water
decarbonised water
deionised water
distilled water
drinking water
fire-fighting water
fully desalinated water (see deionised water)
heating water
partly desalinated water (see
Content
max %
max.
Temperature
max in C
max.
min. 20
decarbonised water)
1)
2)
3)
4)
25
40
Movitec
14
15
16
17
V/VE
VS 2)
V1)/VE1)
V1)/VE1)
V/VE
V/VE
V 1)
V 1)
-
V 1)
-
V1)/VE1)
V/VE
V1)/VE1)
VS
-
V
-
V 1)
VS
-
LHS
LHS
Only valid if all standard (brass) plugs of the Movitec V are replaced by stainless steel plugs. Otherwise use a Movitec VS pump with the right
seal.
The water treatment shall be in accordance with the VdTV guidelines for feed and boiler water in steam plants of up to 64 bar.
The penetration of air into the system must be avoided by all means.
Pure media containing no abrasive solids.
Please contact KSB with detailed information on the fluid to be handled !
16
60 Hz
Movitec
Movitec VE with standard KSB motor 3~230/400 V
Pump size
Number
of
stages
Seal
code
Motor
rating
Rated
current
Thread
Movitec VE
kW
Inom in A
Ident No.
kg
2 poles
Movitec VE 2
Movitec VE 2
Movitec VE 2
Movitec VE 2
1
2
3
4
11
11
11
11
0.37
0.37
0.55
0.75
2.4
2.4
2.6
3.7
/
/
/
/
1.4
1.4
1.5
2.1
47 109 651
47 109 652
47 109 653
47 109 654
12.7
12.7
15.2
18.3
Movitec VE 4
Movitec VE 4
Movitec VE 4
Movitec VE 4
1
2
3
4
11
11
11
11
0.37
0.55
0.75
1.1
2.4
2.6
3.7
5.1
/
/
/
/
1.4
1.5
2.1
2.9
47 109 770
47 109 771
47 109 772
47 109 773
12.7
14.7
17.8
19.6
17
60 Hz
Movitec
Movitec V with standard KSB motor 3~230/400 V
Pump size
Number
of
stages
Seal
code
Motor
rating
Rated
current
Oval flange
Movitec V
kW
Inom in A
Ident No.
Round flange
Movitec VF
kg
Ident No.
Victaulic coupling
Movitec VV
kg
Ident No.
kg
2 poles
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
Movitec V 2
1
2
3
4
5
6
7
8
9
10
11
13
15
16
18
13
13
13
13
13
13
13
13
13
13
13
13
13
13
13
0.37
0.37
0.55
0.75
1.1
1.1
1.5
1.5
1.5
2.2
2.2
2.2
3
3
4
2.4
2.4
2.6
3.7
5.1
5.1
7.8
7.8
7.8
10.9
10.9
10.9
12.4
12.4
16.0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1.4
1.4
1.5
2.1
2.9
2.9
4.5
4.5
4.5
6.3
6.3
6.3
7.2
7.2
9.2
47 109 656
47 109 657
47 109 658
47 109 659
47 109 660
47 109 661
47 109 662
47 109 663
47 109 664
47 109 665
-
13.3
13.3
15.7
19.0
20.8
21.3
25.3
25.8
26.3
29.7
-
47 109 666
47 109 667
47 109 668
47 109 669
47 109 670
30.8
31.8
42.7
43.1
53.1
47 109 707
47 109 708
47 109 709
47 109 710
47 109 711
47 109 712
47 109 713
47 109 714
47 109 715
47 109 716
47 109 717
47 109 718
47 109 719
47 109 720
47 109 721
13.3
13.3
15.7
19.0
20.8
21.3
25.3
25.8
26.3
29.7
30.2
31.1
42.0
42.5
52.4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
Movitec V 4
1
2
3
4
5
6
7
8
9
10
11
13
15
16
13
13
13
13
13
13
13
13
13
13
13
13
13
13
0.37
0.55
0.75
1.1
1.5
1.5
2.2
2.2
3
3
3
4
4
5.5
2.4
2.6
3.7
5.1
7.8
7.8
10.9
10.9
12.4
12.4
12.4
16.0
16.0
21.0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1.4
1.5
2.1
2.9
4.5
4.5
6.3
6.3
7.2
7.2
7.2
9.2
9.2
12.1
47 109 774
47 109 775
47 109 776
47 109 777
47 109 778
47 109 779
47 109 780
47 109 781
47 109 782
47 109 783
-
13.3
15.3
18.6
20.3
24.4
24.9
28.3
28.8
39.3
39.7
-
47 109 784
47 109 785
47 109 786
47 109 787
40.2
50.1
51.0
59.2
47 109 824
47 109 825
47 109 826
47 109 827
47 109 828
47 109 829
47 109 830
47 109 831
47 109 832
47 109 833
47 109 834
47 109 835
47 109 836
47 109 837
13.3
15.3
18.6
20.3
24.4
24.9
28.3
28.8
39.3
39.7
40.2
50.1
51.0
57.6
Movitec V 10
Movitec V 10
Movitec V 10
Movitec V 10
Movitec V 10
Movitec V 10
Movitec V 10
Movitec V 10
Movitec V 10
Movitec V 10
Movitec V 10
1
2
3
4
5
6
7
8
10
12
14
13
13
13
13
13
13
13
13
13
13
13
0.75
1.5
2.2
3
3
4
5.5
5.5
7.5
7.5
11
3.7
7.8
10.9
12.4
12.4
16.0
21.0
21.0
24.8
24.8
47.3
/
/
/
/
/
/
/
/
/
/
/
2.1
4.5
6.3
7.2
7.2
9.2
12.1
12.1
14.3
14.3
27.3
47 109 874
47 109 875
47 109 876
47 109 877
47 109 878
47 109 879
47 109 880
47 109 881
-
23.2
28.2
31.9
42.8
43.5
53.2
60.0
60.7
-
47 109 882
47 109 883
47 109 884
68.7
70.1
137.7
47 109 915
47 109 916
47 109 917
47 109 918
47 109 919
47 109 920
47 109 921
47 109 922
47 109 923
47 109 924
47 109 925
23.2
28.2
31.9
42.8
43.5
53.2
60.0
60.7
66.1
67.5
135.0
2
4
6
8
10
12
14
16
18
20
13
13
13
13
13
13
13
13
13
13
0.55
1.1
1.5
2.2
3
4
4
5.5
5.5
7.5
4.5
4.8
6.5
8.4
14.5
17.5
17.5
19.8
19.8
27.0
/
/
/
/
/
/
/
/
/
/
2.6
2.8
3.7
4.9
8.4
10.1
10.1
11.5
11.5
15.6
47 109 944
47 109 945
47 109 946
47 109 947
47 109 948
47 109 949
47 109 950
47 109 951
47 109 952
47 109 953
22.3
29.0
33.1
44.4
47.0
56.6
58.2
92.9
94.5
107.1
47 109 968
47 109 969
47 109 970
47 109 971
47 109 972
47 109 973
47 109 974
47 111 954
47 109 975
47 109 976
22.3
29.0
33.1
44.4
47.0
56.6
58.2
92.9
94.5
107.1
4 poles
Movitec V 14
Movitec V 14
Movitec V 14
Movitec V 14
Movitec V 14
Movitec V 14
Movitec V 14
Movitec V 14
Movitec V 14
Movitec V 14
18
60 Hz
Movitec
Movitec V with standard KSB motor 3~230/400 V
Pump size
Number
of
stages
Seal
code
Motor
rating
Rated
current
Oval flange
Movitec V
kW
Inom in A
Ident No.
Round flange
Movitec VF
kg
Ident No.
Victaulic coupling
Movitec VV
kg
Ident No.
kg
2 poles
1
2
3
4
5
6
7
8
9
10
12
13
13
13
13
13
13
13
13
13
13
13
2.2
4
5.5
7.5
7.5
11
11
15
15
18.5
18.5
10.9
16.0
21.0
24.8
24.8
47.3
47.3
56.3
56.3
72.1
72.1
/
/
/
/
/
/
/
/
/
/
/
6.3
9.2
12.1
14.3
14.3
27.3
27.3
32.5
32.5
41.6
41.6
47 109 986
47 109 987
47 109 988
47 109 989
47 109 990
47 109 991
47 109 992
-
31.6
50.8
57.8
62.7
63.6
130.6
131.5
-
47 110 017
47 110 018
47 110 019
47 110 020
47 110 021
47 110 022
47 110 023
47 110 024
47 110 025
47 110 026
47 110 027
36.1
55.4
62.3
67.2
68.1
135.2
136.1
151.0
151.9
167.8
169.6
47 110 052
47 110 053
47 110 054
47 110 055
47 110 056
47 110 057
47 110 058
47 110 059
47 110 060
47 110 061
47 110 062
31.6
50.8
57.8
62.7
63.6
130.6
131.5
146.4
147.3
163.2
165.0
1
2
3
4
5
6
7
8
9
10
11
12
16
13
13
13
13
13
13
13
13
13
13
13
13
13
1.1
1.5
2.2
3
4
5.5
5.5
7.5
7.5
7.5
7.5
11
15
4.8
6.5
8.4
14.5
17.5
19.8
19.8
27.0
27.0
27.0
27.0
44.0
57.4
/
/
/
/
/
/
/
/
/
/
/
/
/
2.8
3.7
4.9
8.4
10.1
11.5
11.5
15.6
15.6
15.6
15.6
25.3
33.0
47 110 084
47 110 085
47 110 086
47 110 087
47 110 088
47 110 089
47 110 090
47 110 091
47 110 092
47 110 093
47 110 094
47 110 095
47 110 096
56.8
61.6
72.5
75.8
86.2
122.1
124.4
137.8
140.1
142.5
144.8
194.8
216.2
Movitec V 32
Movitec V 32
Movitec V 32
Movitec V 32
Movitec V 32
Movitec V 32
Movitec V 32
1
2
3
4
5
6
7
13
13
13
13
13
13
13
3
7.5
11
15
15
18.5
22
12.4
24.8
47.3
56.3
56.3
72.1
78.8
/
/
/
/
/
/
/
7.2
14.3
27.3
32.5
32.5
41.6
45.5
47 110 120
47 110 121
47 110 122
47 110 123
47 110 124
47 110 125
47 110 126
69.9
91.2
162.5
178.8
181.1
198.4
236.7
Movitec V 45
Movitec V 45
Movitec V 45
Movitec V 45
Movitec V 45
Movitec V 45
Movitec V 45
1-1
1
2-1
2
3-1
3
4-1
13
13
13
13
13
13
13
3
5.5
11
11
15
18.5
22
12.4
21.0
47.3
47.3
56.3
72.1
78.8
/
/
/
/
/
/
/
7.2
12.1
27.3
27.3
32.5
41.6
45.5
47 110 160
47 110 161
47 110 162
47 110 163
47 110 164
47 110 165
47 110 166
70.9
86.0
161.3
161.4
177.7
192.8
230.9
Movitec V 65
Movitec V 65
Movitec V 65
Movitec V 65
Movitec V 65
1
2
3
4
5
13
13
13
13
13
5.5
11
15
18.5
22
21.0
47.3
56.3
72.1
78.8
/
/
/
/
/
12.1
27.3
32.5
41.6
45.5
47 110 185
47 110 186
47 110 187
47 110 188
47 110 189
93.1
166.7
184.1
202.5
241.9
Movitec V 18
Movitec V 18
Movitec V 18
Movitec V 18
Movitec V 18
Movitec V 18
Movitec V 18
Movitec V 18
Movitec V 18
Movitec V 18
Movitec V 18
4 poles
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
Movitec V 24
2 poles
19
60 Hz
Movitec
Movitec V with standard KSB motor 3~400/692 V
Pump size
Number
of
stages
Seal
code
Motor
rating
Rated
current
Round flange
Movitec VF
kW
Inom in A
Ident No.
kg
2 poles
Movitec V 32
Movitec V 32
8
9
13
13
30
30
53.1 / 30.7
53.1 / 30.7
47 111 940
47 111 941
358.8
365.1
Movitec V 45
Movitec V 45
Movitec V 45
Movitec V 45
Movitec V 45
4
5-1
5
6-1
6
13
13
13
13
13
30
30
30
37
37
53.1
53.1
53.1
65.3
65.3
47 111 944
47 111 945
47 111 946
47 111 947
47 111 948
355.0
357.4
357.4
359.8
359.8
20
/
/
/
/
/
30.7
30.7
30.7
37.7
37.7
60 Hz
Movitec
Movitec VS with standard KSB motor 3~230/400 V
Pump size
Number
of
stages
Seal
code
Motor
rating
Rated
current
Oval flange
Movitec VS
kW
Inom in A
Ident No.
Round flange
Movitec VSF
kg
Ident No.
Victaulic coupling
Movitec VSV
kg
Ident No.
kg
2 poles
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
Movitec VS 2
1
2
3
4
5
6
7
8
9
10
11
13
15
16
18
14
14
14
14
14
14
14
14
14
14
14
14
14
14
14
0.37
0.37
0.55
0.75
1.1
1.1
1.5
1.5
1.5
2.2
2.2
2.2
3
3
4
2.4
2.4
2.6
3.7
5.1
5.1
7.8
7.8
7.8
10.9
10.9
10.9
12.4
12.4
16.0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1.4
1.4
1.5
2.1
2.9
2.9
4.5
4.5
4.5
6.3
6.3
6.3
7.2
7.2
9.2
47 110 249
47 110 250
47 110 251
47 110 252
47 110 253
47 110 254
47 110 255
47 110 256
47 110 257
47 110 258
-
13.3
13.3
15.7
19.0
20.8
21.3
25.3
25.8
26.3
29.7
-
47 110 259
47 110 260
47 110 261
47 110 262
47 110 263
30.8
31.8
42.7
43.1
53.1
47 110 300
47 110 301
47 110 302
47 110 303
47 110 304
47 110 305
47 110 306
47 110 307
47 110 308
47 110 309
47 110 310
47 110 311
47 110 312
47 110 313
47 110 314
13.3
13.3
15.7
19.0
20.8
21.3
25.3
25.8
26.3
29.7
30.2
31.1
42.0
42.5
52.4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
Movitec VS 4
1
2
3
4
5
6
7
8
9
10
11
13
15
16
14
14
14
14
14
14
14
14
14
14
14
14
14
14
0.37
0.55
0.75
1.1
1.5
1.5
2.2
2.2
3
3
3
4
4
5.5
2.4
2.6
3.7
5.1
7.8
7.8
10.9
10.9
12.4
12.4
12.4
16.0
16.0
21.0
/
/
/
/
/
/
/
/
/
/
/
/
/
/
1.4
1.5
2.1
2.9
4.5
4.5
6.3
6.3
7.2
7.2
7.2
9.2
9.2
12.1
47 110 351
47 110 352
47 110 353
47 110 354
47 110 355
47 110 356
47 110 357
47 110 358
47 110 359
47 110 360
-
13.3
15.3
18.6
20.3
24.4
24.9
28.3
28.8
39.3
39.7
-
47 110 361
47 110 362
47 110 363
47 110 364
40.2
50.1
51.0
59.2
47 110 401
47 110 402
47 110 403
47 110 404
47 110 405
47 110 406
47 110 407
47 110 408
47 110 409
47 110 410
47 110 411
47 110 412
47 110 413
47 111 955
13.3
15.3
18.6
20.3
24.4
24.9
28.3
28.8
39.3
39.7
40.2
50.1
51.0
57.6
Movitec VS 10
Movitec VS 10
Movitec VS 10
Movitec VS 10
Movitec VS 10
Movitec VS 10
Movitec VS 10
Movitec VS 10
Movitec VS 10
Movitec VS 10
Movitec VS 10
1
2
3
4
5
6
7
8
10
12
14
14
14
14
14
14
14
14
14
14
14
14
0.75
1.5
2.2
3
3
4
5.5
5.5
7.5
7.5
11
3.7
7.8
10.9
12.4
12.4
16.0
21.0
21.0
24.8
24.8
47.3
/
/
/
/
/
/
/
/
/
/
/
2.1
4.5
6.3
7.2
7.2
9.2
12.1
12.1
14.3
14.3
27.3
47 110 444
47 110 445
47 110 446
47 110 447
47 110 448
47 110 449
47 110 450
47 110 451
-
23.2
28.2
31.9
42.8
43.5
53.2
60.0
60.7
-
47 110 452
47 110 453
47 110 454
68.7
70.1
137.7
47 110 485
47 110 486
47 110 487
47 110 488
47 110 489
47 110 490
47 110 491
47 110 492
47 110 493
47 110 494
47 110 495
23.2
28.2
31.9
42.8
43.5
53.2
60.0
60.7
66.1
67.5
135.0
2
4
6
8
10
12
14
16
18
20
14
14
14
14
14
14
14
14
14
14
0.55
1.1
1.5
2.2
3
4
4
5.5
5.5
7.5
4.5
4.8
6.5
8.4
14.5
17.5
17.5
19.8
19.8
27.0
/
/
/
/
/
/
/
/
/
/
2.6
2.8
3.7
4.9
8.4
10.1
10.1
11.5
11.5
15.6
47 110 510
47 110 511
47 110 512
47 110 513
47 110 514
47 110 515
47 110 516
47 110 517
47 110 518
47 110 519
22.3
29.0
33.1
44.4
47.0
56.6
58.2
92.9
94.5
107.1
--
47 110 534
47 110 535
47 110 536
47 110 537
47 110 538
47 110 539
47 110 540
47 110 541
47 110 542
47 110 543
22.3
29.0
33.1
44.4
47.0
56.6
58.2
92.9
94.5
107.1
4 poles
Movitec VS 14
Movitec VS 14
Movitec VS 14
Movitec VS 14
Movitec VS 14
Movitec VS 14
Movitec VS 14
Movitec VS 14
Movitec VS 14
Movitec VS 14
21
60 Hz
Movitec
Movitec VS with standard KSB motor 3~230/400 V
Pump size
Number
of
stages
Seal
code
Motor
rating
Rated
current
Oval flange
Movitec VS
kW
Inom in A
Ident No.
Round flange
Movitec VSF
kg
Ident No.
Victaulic coupling
Movitec VSV
kg
Ident No.
kg
2 poles
1
2
3
4
5
6
7
8
9
10
12
14
14
14
14
14
14
14
14
14
14
14
2.2
4
5.5
7.5
7.5
11
11
15
15
18.5
18.5
10.9
16.0
21.0
24.8
24.8
47.3
47.3
56.3
56.3
72.1
72.1
/
/
/
/
/
/
/
/
/
/
/
6.3
9.2
12.1
14.3
14.3
27.3
27.3
32.5
32.5
41.6
41.6
47 110 552
47 110 553
47 110 554
47 110 555
47 110 556
47 110 557
47 110 558
-
31.6
50.8
57.8
62.7
63.6
130.6
131.5
-
47 110 583
47 110 584
47 110 585
47 110 586
47 110 587
47 110 588
47 110 589
47 110 590
47 110 591
47 110 592
47 110 593
36.1
55.4
62.3
67.2
68.1
135.2
136.1
151.0
151.9
167.8
169.6
47 110 618
47 110 619
47 110 620
47 110 621
47 110 622
47 110 623
47 110 624
47 110 625
47 110 626
47 110 627
47 110 628
31.6
50.8
57.8
62.7
63.6
130.6
131.5
146.4
147.3
163.2
165.0
1
2
3
4
5
6
7
8
9
10
11
12
16
14
14
14
14
14
14
14
14
14
14
14
14
14
1.1
1.5
2.2
3
4
5.5
5.5
7.5
7.5
7.5
7.5
11
15
4.8
6.5
8.4
14.5
17.5
19.8
19.8
27.0
27.0
27.0
27.0
44.0
57.4
/
/
/
/
/
/
/
/
/
/
/
/
/
2.8
3.7
4.9
8.4
10.1
11.5
11.5
15.6
15.6
15.6
15.6
25.3
33.0
47 110 650
47 110 651
47 110 652
47 110 653
47 110 654
47 110 655
47 110 656
47 110 657
47 110 658
47 110 659
47 110 660
47 110 661
47 110 662
56.8
61.6
72.5
75.8
86.2
122.1
124.4
137.8
140.1
142.5
144.8
194.8
216.2
Movitec VS 32
Movitec VS 32
Movitec VS 32
Movitec VS 32
Movitec VS 32
Movitec VS 32
Movitec VS 32
1
2
3
4
5
6
7
14
14
14
14
14
14
14
3
7.5
11
15
15
18.5
22
12.4
24.8
47.3
56.3
56.3
72.1
78.8
/
/
/
/
/
/
/
7.2
14.3
27.3
32.5
32.5
41.6
45.5
47 110 686
47 110 687
47 110 688
47 110 689
47 110 690
47 110 691
47 110 692
69.9
91.2
162.5
178.8
181.1
198.4
236.7
Movitec VS 45
Movitec VS 45
Movitec VS 45
Movitec VS 45
Movitec VS 45
Movitec VS 45
Movitec VS 45
1-1
1
2-1
2
3-1
3
4-1
14
14
14
14
14
14
14
3
5.5
11
11
15
18.5
22
12.4
21.0
47.3
47.3
56.3
72.1
78.8
/
/
/
/
/
/
/
7.2
12.1
27.3
27.3
32.5
41.6
45.5
47 110 725
47 110 726
47 110 727
47 110 728
47 110 729
47 110 730
47 110 731
70.9
86.0
161.3
161.4
177.7
192.8
230.9
Movitec VS 65
Movitec VS 65
Movitec VS 65
Movitec VS 65
Movitec VS 65
1
2
3
4
5
14
14
14
14
14
5.5
11
15
18.5
22
21.0
47.3
56.3
72.1
78.8
/
/
/
/
/
12.1
27.3
32.5
41.6
45.5
47 110 750
47 110 751
47 110 752
47 110 753
47 110 754
93.1
166.7
184.1
202.5
241.9
Movitec VS 18
Movitec VS 18
Movitec VS 18
Movitec VS 18
Movitec VS 18
Movitec VS 18
Movitec VS 18
Movitec VS 18
Movitec VS 18
Movitec VS 18
Movitec VS 18
4 poles
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
Movitec VS 24
2 poles
22
60 Hz
Movitec
Movitec VS with standard KSB motor 3~400/692 V
Pump size
Number
of
stages
Seal
code
Motor
rating
Rated
current
Round flange
Movitec VSF
kW
Inom in A
Ident No.
kg
2 poles
Movitec VS 32
Movitec VS 32
8
9
14
14
30
30
53.1 / 30.7
53.1 / 30.7
47 111 942
47 111 943
358.8
365.1
Movitec VS 45
Movitec VS 45
Movitec VS 45
Movitec VS 45
Movitec VS 45
4
5-1
5
6-1
6
14
14
14
14
14
30
30
30
37
37
53.1
53.1
53.1
65.3
65.3
47 111 949
47 111 950
47 111 951
47 111 952
47 111 953
355.0
357.4
357.4
359.8
359.8
/
/
/
/
/
30.7
30.7
30.7
37.7
37.7
23
60 Hz
Movitec
Movitec LHS with standard KSB motor 3~230/400 V
Pump size
Number
of
stages
Seal
code
Motor
rating
Rated
current
Round flange
Movitec LHS
kW
Inom in A
Ident No.
kg
2 poles
Movitec LHS 6
Movitec LHS 6
Movitec LHS 6
Movitec LHS 6
24
8
10
12
14
17
17
17
17
7.5
11
11
15
24.8
47.3
47.3
56.3
/
/
/
/
14.3
27.3
27.3
32.5
47 110 762
47 110 763
47 110 764
47 110 765
96.1
165.2
168.2
185.2
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
60 Hz
Movitec
Dimension Tables
Movitec VE 2
3500 1/min
VE 2
E1
E2
F1
134
107
413
134
107
413
134
107
458
150
115
470
E1
E2
F1
134
107
413
134
107
437
150
115
449
150
115
500
No. of stages
Dimensions in mm
Movitec VE 4
3500 1/min
VE 4
No. of stages
Dimensions in mm
60 Hz
Movitec
Dimension Tables
Movitec V 2
3500 1/min
Oval flange
Victaulic flange
V2
E1
E2
F1
F2
F1
F2
134
107
451
232
476
257
134
107
451
232
476
257
134
107
496
253
521
278
150
115
518
284
543
309
150
115
569
305
594
330
150
115
590
326
615
351
176
136
632
357
657
382
176
136
653
378
678
403
176
136
674
399
699
424
10
176
136
695
420
720
445
No. of stages
11
176
136
716
441
741
466
13
176
136
758
483
783
508
15
194
147
851
535
876
560
16
194
147
872
556
897
581
18
233
162
922
598
947
623
Dimensions in mm
Flange Variants
Oval flange PN 16
Movitec V(S)
Round flange PN 25
Movitec V(S) F
Round flange
Victaulic PN 25
Movitec V(S) V
60 Hz
Movitec
Dimension Tables
Movitec V 4
3500 1/min
Oval flange
Victaulic
V4
Round flange
E1
E2
F1
F2
F1
F2
134
107
451
232
476
257
134
107
475
232
500
257
150
115
497
263
522
288
150
115
548
284
573
309
176
136
590
315
615
340
176
136
611
336
636
361
176
136
632
357
657
382
176
136
653
378
678
403
194
147
725
409
750
434
10
194
147
746
430
771
455
No. of stages
11
194
147
767
451
792
476
13
233
162
817
493
842
518
15
233
162
859
535
884
560
16
233
162
885
556
910
581
Dimensions in mm
Flange Variants
Oval flange PN 16
Movitec V(S)
Round flange PN 25
Movitec V(S) F
Victaulic PN 25
Movitec V(S) V
60 Hz
Movitec
Dimension Tables
Movitec V 10
3500 1/min
V 10
No. of stages
E1
E2
F1
F2
150
115
556
322
176
136
607
332
176
136
634
359
194
147
712
396
194
147
739
423
233
162
774
450
233
162
826
497
233
162
853
524
10
233
162
935
578
12
233
162
989
632
14
315
206
1218
716
Dimensions in mm
Flange Variants
Oval flange PN 16
Movitec V(S)
Round flange PN 25
Movitec V(S) F
Victaulic PN 25
Movitec V(S) V
60 Hz
Movitec
Dimension Tables
Movitec V 14
1750 1/min
V 14
E1
E2
F1
F2
156
119
558
322
173
112
643
386
173
136
720
440
No. of stages
200
151
817
504
10
198
150
872
558
12
225
168
935
612
14
225
168
989
666
16
255
181
1100
740
18
255
181
1154
794
20
255
181
1248
848
Dimensions in mm
Flange Variants
Oval flange PN 16
Movitec V(S)
Victaulic PN 25
Movitec V(S) V
60 Hz
Movitec
Dimension Tables
Movitec V 18
3500 1/min
V 18
E1
E2
F1
F2
176
136
632
357
233
162
691
367
233
162
750
421
233
162
813
456
233
162
847
490
315
206
1057
555
315
206
1091
589
315
206
1126
624
No. of stages
315
206
1160
658
10
315
206
1239
693
12
315
206
1308
762
Dimensions in mm
Flange Variants
Oval flange PN 16
Movitec V(S)
Round flange PN 25
Movitec V(S) F
Victaulic PN 25
Movitec V(S) V
60 Hz
Movitec
Dimension Tables
Movitec VF 24
1750 1/min
VF 24
E1
E2
F1
F2
176
136
738
458
176
136
786
506
194
147
871
555
194
147
919
603
233
162
976
652
266
179
1103
720
266
179
1152
769
266
179
1238
817
266
179
1287
866
10
266
179
1335
914
No. of stages
11
266
179
1384
963
12
312
230
1553
1116
16
312
230
1787
1310
Dimensions in mm
Flange Variants
Round flange PN 25
Movitec V(S) F
60 Hz
Movitec
Dimension Tables
Movitec VF 32
3500 1/min
VF 32
E1
E2
F1
F2
194
147
774
458
233
162
883
526
315
206
1182
680
315
206
1230
728
315
206
1279
777
315
206
1371
825
350
225
1469
874
398
323
1592
922
398
323
1641
971
No. of stages
Dimensions in mm
Flange Variants
Round flange PN 25
Movitec V(S) F
60 Hz
Movitec
Dimension Tables
Movitec VF 45
3500 1/min
VF 45
E1
E2
F1
F2
1-1
194
147
774
458
233
162
807
478
2-1
315
206
1133
631
315
206
1133
631
3-1
315
206
1182
680
315
206
1226
680
4-1
350
225
1323
728
398
323
1398
728
5-1
398
323
1447
777
398
323
1447
777
6-1
398
323
1495
825
398
323
1495
825
No. of stages
Dimensions in mm
Flange Variants
Round flange PN 25
Movitec V(S) F
60 Hz
Movitec
Dimension Tables
Movitec VF 65
3500 1/min
Round flanges
PN 16
VF 65
E1
E2
F1
F2
233
162
919
590
315
206
1211
709
315
206
1300
798
315
206
1433
887
350
225
1571
976
No. of stages
Dimensions in mm
Flange Variants
Round flanges PN 16
60 Hz
Movitec
Dimension Tables
Movitec LHS 6 3500 1/min
LHS 6
No. of stages
E1
E2
F1
F2
233
162
539
896
10
315
206
629
1131
12
315
206
688
1190
14
315
206
748
1250
Dimensions in mm
Flange Variants
Round flange PN 40
Position 3
(Standard Movitec V, VS, LHS)
Position 9
(Standard Movitec VE)
Position 6
Position 12
(not for Movitec VE)
47
60 Hz
Movitec
Sectional Drawing
Movitec VE 2, 4
20030219- B
48
60 Hz
Movitec
Pump shroud
Pump casing
Stage casing
Stage casing, bottom
Stage casing, upper
Cover
Impeller
Motor stool
Joint ring
Joint ring
Joint ring
O-ring
O-ring
Mechanical seal
Spacer sleeve, long
Spacer sleeve, end
Spacer sleeve, seal
Washer
Non-return valve
Motor for close coupling
Baseplate, cast
Screwed plug
Screwed plug
Screwed plug
Tie bolt
Hexagon socket head cap screw
Nut lock with non metallic insert
Nut
Safety device nord-lock
Circlip
49
60 Hz
Movitec
Sectional Drawing
95000589- F
50
60 Hz
Movitec
Pump shroud
Pump casing
Stage casing
Stage casing, with ceramic bearing
Stage casing, bottom
Stage casing, upper
Cover
Shaft
Impeller
Motor stool
Gasket, oval
Joint ring
Joint ring EPDM
O-ring
O-ring
O-ring
O-ring
Mechanical seal
Spacer sleeve, short
Spacer sleeve, long
Spacer sleeve, end
Spacer sleeve, seal
Bearing sleeve
Washer
Washer
Washer
Pin
Coupling guard
Flange, oval
Motor (> 5,5 kW 801 Flange motor)
Coupling shell
Baseplate, cast
Hexagon head bolt
Hexagon head bolt
Hexagon head bolt
Screwed plug
Screwed plug
Tie bolt
Hexagon socket head cap screw
Nut
Nut lock, with non metallic insert
Nut
Safety device, nord-lock
Circlip (1/1)
51
60 Hz
Movitec
Sectional Drawing
Movitec VF 24, 32, 45
20010712- D
52
60 Hz
Movitec
Pump shroud
Pump casing
Stage casing, bottom
Cover
Diffuser
Diffuser, with ceramic bearing
Diffuser, upper
Shaft
Impeller (for Movitec VF 24 and 32)
Impeller (for Movitec VF 45)
Impeller, half head (for Movitec VF 45)
Motor stool
Joint ring
O-ring
O-ring
O-ring
O-ring
O-ring
O-ring
Mechanical seal
Seal cover
Ring, cartridge
Intermediate ring
Intermediate ring, upper
Spacer sleeve, short
Spacer sleeve, long
Spacer sleeve, end
Spacer sleeve, seal
Spacer sleeve, seal extention
Spacer sleeve, cartridge
Bearing sleeve
Washer
Pin
Coupling guard
Motor (> 5,5 kW 801 Flange motor)
Coupling shell
Baseplate, cast
Hexagon head bolt
Screwed plug
Screwed plug
Grub screw
Tie bolt
Hexagon socket head cap screw
Hexagon socket head cap screw
Hexagon socket head cap screw
Nut
Nut, lock with non metallic insert
Nut
Safety device, nord-lock
Circlip (1/2)
53
60 Hz
Movitec
Sectional Drawing
Movitec VF 65
20010752- E
54
60 Hz
Movitec
Pump shroud
Pump casing
Cover
Diffuser
Diffuser, with ceramic bearing
Shaft
Impeller
Motor stool
Joint ring
O-ring
O-ring
O-ring
O-ring
O-ring
Mechanical seal
Seal cover
RingCartridge
Intermediate ring
Intermediate ring, upper
Intermediate ring, lower
Spacer sleeve, short
Spacer sleeve, middle
Spacer sleeve, long
Spacer sleeve, end
Spacer sleeve, seal
Spacer sleeve, cartridge
Bearing sleeve
Disc Bottom
Washer
Washer
Pin
Coupling guard
Tap piece, flanged
Flange motor
Coupling shell
Baseplate, cast
Hexagon head bolt
Hexagon head bolt
Screwed plug
Screwed plug
Grub screw
Tie bolt
Hexagon socket head cap screw
Hexagon socket head cap screw
Hexagon socket head cap screw
Nut
Nut lock with non metallic insert
Nut
Nut
Safety device, nord-lock
Circlip (1/2)
55
60 Hz
Movitec
Sectional Drawing
Movitec LHS 6
20030238- B
56
60 Hz
Movitec
Pump shroud
Pump casing
Stage casing
Stage casing with ceramic bearing
Stage casing, bottom
Stage casing, upper
Shaft
Impeller
Motor stool
Joint ring
Joint ring
O-ring
O-ring
Mechanical seal
Spacer sleeve, short
Spacer sleeve, middle
Spacer sleeve, long
Spacer sleeve, end
Spacer sleeve, seal
Bearing sleeve
Washer
Washer
Washer
Pin
Coupling guard
Tap piece, flanged
Motor
Coupling shell
Hexagon head bolt
Hexagon head bolt
Hexagon head bolt
Screwed plug
Screwed plug
Tie bolt
Hexagon socket head cap screw
Nut
Nut lock with non metallic insert
Nut
Nut
Safety device nord-lock
Circlip
57
60 Hz
Movitec
58
60 Hz
Movitec
59
1798.56-10
1.10.2004
Movitec