The Andhra Pradesh Boiler Operation Engineer Rules stipulate that the owner of a single Boiler or two or more Boilers connected in a Battery of so many separate individual Boilers situated within a radius of 75 feet, having a total heating surface exceeding 7500 square feet in any of the cases, shall not use the same or permit the same to be used unless the Boiler or Boilers are placed in direct charge of a person holding a Boiler operation Engineers Certificate. The owner of a Boiler who works or permits or causes the Boilers to be worked at any time in contravention of the above rules shall be punishable with penalties stipulated in these rules. The objective of these rules is the safe and efficient working of Boilers. Form of application for Examination for certificate of proficiency as Boiler Operation Engineer is in annexure VI BOE Boiler operation Engineers 2011
The owner/ person of a single boiler or two or more boilers connected in a battery or of many separate individual boilers situated within the radius of 50 meters having the total heating surface exceeding one thousand square meters in any of the case shall not use or permit to use the boilers unless he possess a certificate of proficiency as a Boiler Operation Engineer under Boiler Operation Engineers Rules 2011
The A. P. Boiler Attendant Rules, 1956 The Andhra Pradesh Boiler Attendant Rules stipulate that the owner of a Boiler shall not use the Boiler or permit it to be used unless it is under the direct and immediate charge of a person holding a Boiler Attendants certificate. These rules also stipulate constitution of Board of Examiners and their functions, required qualifications of the candidates, mode of Conducting examinations and issue of certificate. Two grades of certificates are issued under these rules. A second class Boiler Attendant Certificate qualifies the holder thereof to be in charge of a single Boiler of any kind the heating surface of which does not exceeds 1500 square feet. A second class Boiler Attendant may, however, attend to Battery of Boilers (not consisting of more than three connected Boilers and not exceeding 1500 square feet in aggregate of total heating surface). Provided he is assisted by the number of firemen considered necessary by the Chief Inspector of Boilers. A first class Boiler Attendant Certificate qualifies the holder thereof to be in charge of a single Boiler of any type or capacity or two or more Boilers in a Battery of so many individual Boilers, the total heating surface of which does not exceeds 7500 square feet provided that in case of two or more Boilers such Boilers shall be situated within a radius of 75 feet, in the same premises and belonging to one owner, and in such case he shall be assisted by a second class Boiler Attendant or the number of firemen considered necessary by the Chief Inspector of Boilers.
Boiler Attendant Rules 2011 There shall be two classes of certificates of competency granted under these Rules namely: First Class Boiler Attendant certificate Second Class Boiler Attendant certificate The owner/ person of a single boiler with steam pipes of any type or capacity of two or more boilers connected in a battery or of many separate individual boilers situated within the radius of 30 meters having the total heating surface not exceeding one thousand square meters in any of the case shall not use or permit to use the boilers unless he possess a certificate of competency as a First Class Boiler Attendant under Boiler Attendant Rules 2011 The owner/ person of a single boiler with steam pipes of any type or capacity of three boilers connected in a battery having the total heating surface not exceeding two hundred square meters aggregate in any of the case shall not use or permit to use the boilers unless he possess a certificate of competency as a Second Class Boiler Attendant under Boiler Attendant Rules 2011
The Traveling Engineers' Association to Improve the Locomotive Engine Service of American Railroads
Examination Questions and Answers for Firemen for Promotion and New Men for Employment