UK Product Catalogue
A Tyco International Company
New_Intruder_Covers 3:Layout 1 23/08/2010 13:17 Page 1
Intruder Catalogue Intruder Catalogue Intruder Catalogue i
Introduction
03/12
The Tyco EMEA Web site contains an endless supply of product related
information available in multiple languages - English, Dutch, French,
German, Italian, Polish and Spanish. It is regularly updated and features
many aids to the selling process including presentation material and
detailed technical information.
To enhance customer specifications and quotations we also provide a
series of product datasheets which can give our clients an opportunity to
read more about the product.
We are positive that together we can help grow your business and we
look forward to working with you in the future.
Welcome to the 14th Issue of Tyco EMEAs Intruder Product Catalogue containing the wide range of products available
from our distribution centre in Letchworth. We aim to make your product range as comprehensive as possible to ensure
you never need go anywhere else. To meet this goal, our product specialists, with your help, have selected the most
appropriate, cost effective product range available on the market.
In line with our ISO 9000 accreditation, only those products that meet the highest quality criteria have been included.
Our goal is to despatch product on the same day as we receive your order. Our warranty and service returns policy is
second to none. We recognise that your business is highly dependent on excellence in customer service and to help
achieve this we offer extended warranty from many of our suppliers. Full credit is also available on a No Question No
Fuss basis for any new in-warranty product returned to the distribution centre. Our standard duration for warranty is a
minimum of 12 months credit.
For Technical Pre-sales Inquiries:
tfsemea.presales@tycoint.com
For Technical Training Enquiries:
tfsemea.training@tycoint.com
http://www.tycoemea.com/English/Training.asp
For SSA/dongle Requests:
http://www.tycoemea.com/Dongle/index.htm
CONTACT INFORMATION
TYCO International EMEA
Voltaweg 20
6101 XK Echt - The Netherlands
Fax: +31 475 352 725
For Technical Services:
Hours: 8:00 to 18:00 EET, CET, GMT:
(Toll Free): +800CALLTYCO OR
+800 2255 8926
UK: 08081 013 73 OR 08701 238 787
TECHNICAL SUPPORT & PRE-SALES CALL CENTRE
For Technical Post-Sales Enquiries:
tfsemea.support@tycoint.com
www.tycoemea.com
www.calltyco.com
Hours: 8:00 to 18:00 EET, CET, GMT:
(Toll Free): +800CALLTYCO OR +800 2255 8926 UK: 08081 01373 OR 08701 238787
IntroContentpgsIntrudrCat:Layout 1 20/03/2012 11:43 Page 1
Contents
Intruder Catalogue ii 03/12
Introduction i
Contents ii
Introduction of Intruder Alarm to European Standards iii
Chapter 1 - Accessories 1.1
Chapter 2 - Audio Verification 2.1
Chapter 3 - Batteries 3.1
Chapter 4 - Contacts (Magnetic) 4.1
Chapter 5 - Day Alarms 5.1
Chapter 6 - Detectors - Beam 6.1
Chapter 7 - Detectors - Glassbreak 7.1
Chapter 8 - Detectors - Sequential Confirmation 8.1
Chapter 9 - Detectors - Dualtech 9.1
Chapter 10 - Detectors - Passive Infra-Red 10.1
Chapter 11 - Detectors - Vibration 11.1
Chapter 12 - Detectors - Temperature 12.1
Chapter 13 - External Lighting Control 13.1
Chapter 14 - Life Safety Devices 14.1
Chapter 15 - Intruder Alarm Control Panels - Galaxy 15.1
Chapter 16 - Intruder Alarm Control Panels - Domonial 16.1
Chapter 17 - Le Sucre 17.1
Chapter 18 - Perimeter Protection 18.1
Chapter 19 - Power Supply Units 19.1
Chapter 19 - Radio Equipment - Cooper Security 201
Chapter 21 - Radio Equipment - EMS 21.1
Chapter 22 - Signalling 22.1
Chapter 23 - Sounders 23.1
Chapter 24 - Cable 24.1
CONTENTS
IntroContentpgsIntrudrCat:Layout 1 20/03/2012 11:43 Page 2
Intruder Catalogue Chapter 1 Page 1
Chapter 1 - Accessories
03/12
Exit Terminators
Exit terminate buttons are used to provide a final set input to
alarm systems. Generally sited outside the premises,
operation of the exit terminate button is the final action
required in the setting process.
This facility is mandatory in some police authority areas.
Features
Easy Fit
Unobtrusive Design
Sleek Design
Product Codes
1147 Surface mount exit terminate button,
Smith type
1148 Surface mount box for use with 1147 exit
terminate button
1155 Exit terminator switch, magnetic operation
type. White. Requires ferrous object to be
held against it to operate.
1175 ADT key ring for use with magnetic
operation type exit terminator+
609.002.024 Elmdene set switch with white clip on
bezel
DRB002NF ICS S/S Intruder set switch
1155
1148
1147
1175
Accessories
609.002.024
DRB002NF
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 1
Chapter 1 - Accessories
Features
Intruder Catalogue Chapter 1 Page 2 03/12
ELM-PA-G3-B Grade 3 Panic Button - Brass
ELM-PA-G3-SS Grade 3 Panic Button - Brushed Stainless
Steel
ELM-PA-G3-W Grade 3 Panic Button - White
ELM-PA-KEY Pack of 5 spare keys for Panic Buttons
1146 Geutebruck suspicion button
1183 Replacement key for Knight Plastics PA
button
1184 Replacement key for Maximal PA buttons
New Elmdene PABs
A new range of static panic alarm buttons from Elmdene
International that conform to Grade 3 of EN50131-1. The
new range has the benefit of having separate tamper and
alarm contacts, which are necessary for reporting for Grade
3 systems, the tamper being a spring micro switch and the
alarm contacts being a magnetic/reed switch.
All units are Grade 3 Double Push with integral resistors for
use with most control panels or option for Double Pole.
Spare terminals allow through connection for multiple units
wired to one zone.
Special features include integral storage of reset key and
anti-lock reset mechanism to ensure unit still operates if
reset key is left in the unit and silent operation.
Elmdene Panic Buttons fully comply with 'The ACPO 10
Point Plan' and all requirements under EN50131-1:2006 and
PD6662:2004 A1 + A2.
The panic buttons can be wired in fully supervised formats
or traditional without any resistors (no jumpers fitted)
In addition they have clamp down terminals and have
selective resistor value jumpers that can be used for the
following panels;
4k7/2k2 ADE, Bosch, Castle, Menvier, Pyronix,
Scantronic, Texecom
1k/1k Galaxy
8k2/8k2 Guardall
4k7/4k7 Aritech
6k8/4k7 GardTec
2k2/2k2 Europlex
5k6/5k6 DSC
Double Pole (no resistors)
Technical Specification
Silent Operation
FSL and D/P Connection
Multiple Control Panel / Resistor Options
Easy Connection of Multiple Units
Anti-lock Reset Mechanism
Independent Micro Switch Tamper (removal of cover
initiates tamper signal only)
Integral Storage for Rest Key
Selectable Normally Closed or Open Contacts
Product Codes
Product Dimensions Operating Action Magnet Colour Finish Indication
Code HxWxD mm Temp.
ELM-PA-G3-SS 81 x 63.5 x 29 -40
o
C to +50
o
C Silent action, latching (key release) Ferrite Stainless Steel Stainless Steel Flag Indication
ELM-PA-G3-B 81 x 63.5 x 29 -40
o
C to +50
o
C Silent action, latching (key release) Ferrite Brass Brass Flag Indication
ELM-PA-G3-W 81 x 63.5 x 29 -40
o
C to +50
o
C Silent action, latching (key release) Ferrite White Plastic Flag Indication
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 2
Chapter 1 - Accessories
Intruder Catalogue Chapter 1 Page 3 03/12
EN3-JB9-HD-GROMMET Pack of 10 white end
Grommets for HDJBs
EN3-JB9-HD-BN-GROMMET Pack of 10 brown end
Grommets for HDJBs
Door Loops
These are used for looping from door frame to a door.
For use with contacted locks, wired and covered doors etc.
Features
Compact
Various Sizes
Choice of colour
EDL1 30cm fixed length door loop white
EDL2 25cm white door loop extendable
up to 170cm
EDL3 50cm white door loop extendable
up to 330cm
EDL1-BN 30cm fixed length door loop Brown
EDL2-BN 25cm Brown door loop extendable
up to 170cm
EDL3-BN 50cm Brown door loop extendable
up to 330cm
EDL1-KIT 30cm fixed length door loop white
Inc 2 EN3-JB9-HD-W & 2 Grommets
EDL2-KIT 25cm white door loop extendable up
to 170cm Inc 2 EN3-JB9-HD-W & 2
Grommets
EDL3-KIT 50cm white door loop extendable up
to 330cm Inc 2 EN3-JB9-HD-W & 2
Grommets
EDL1-BN-KIT 30cm fixed length door loop Brown
Inc 2 EN3-JB9-HD-W & 2 Grommets
EDL2-BN-KIT 25cm Brown door loop extendable
up to 170cm Inc 2 EN3-JB9-HD-W & 2
Grommets
EDL3-BN-KIT 50cm Brown door loop extendable
up to 330cm Inc 2 EN3-JB9-HD-W & 2
Grommets
Product Codes
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 3
Chapter 1 - Accessories
Intruder Catalogue Chapter 1 Page 4 03/12
Junction Boxes
Designed for use in security applications, these junction
boxes are provided with a tamper connection which will
open circuit whenever the lid is removed.
Features
Real tamper switch with spring operation
Clamp style terminals
Choice of models
Modern design
EN Grade 3 compliant
Product Codes
EN3-JB10 Elmdene 10 way Grade 3 White JB with
Tamper - 8 way plus 2 terminals for
Tamper
EN3-JB10-BN Elmdene 10 way Grade 3 brown JB with
tamper - 8 way plus 2 terminals for
Tamper
EN3-JB9-HD Elmdene 9 way HD Grade 3 white JB with
Tamper and Sealing Gasket - 7 way plus 2
terminals for tamper with environmental
class 3 sealing gasket
EN3-JB9-HD-BN Elmdene 9 way grade 3 brown JB with
tamper with sealing gasket. 7way plus 2
terminals for tamper with environment
class 3 sealing gasket
EN3-JB26 Elmdene 24 way Grade 3 white JB with
Tamper - 24 way plus 2 terminals for
Tamper
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 4
Chapter 1 - Accessories
Intruder Catalogue Chapter 1 Page 5 03/12
Accessories
ACT1313 12Vd.c. Spike Supressor
Induced AC (Electromagnetic
Interference) is caused when Intruder
cables come near mains or telephone
wires. High induced AC voltage
causes random and intermittent false
alarms as well as system
malfunctions.
Very often, mains and other high
voltage cables are run next to alarm
circuits after the system has been
installed. Eliminating induced AC is
simple by fitting a Spike Suppressor
as standard in every control panel or
PSU.
The suppressor connects directly
across the DC supply and to mains
earth, dumping induced AC noise
and clamping the DC voltage against
spikes.
Product Code
3127 ACT1313 12Vdc
Spike Supressor
Mains Filtering
Focus Mains Filter
This unit combines both transient
protection and filter protection. The
unit is designed to be hard-wired into
the mains terminal block across
neutral and earth. To obtain the best
performance from the device, the
leads should be kept as short as
possible. Note the device requires
external fusing which should be no
more than 13 Amps maximum, so it
must be connected downline of the
units fusing the system. The power
must be switched off during
connection.
Product Code
F-2323MSF Focus Mains Filter
Relays
ACT 2468 Radio frequency filter.
The ACT 2468 is a powerful 1 Amp
rated RFI filter specifically designed
for use on any DC troublesome alarm
circuit cable. They are particularly
beneficial where data corruption
occurs to keypads and LIMs
(especially on take-overs). They can
be used to attenuate RFI interference
to alarm detectors and sounders. The
ACT 2468 will work on 12V and
24Vd.c., normally closed, end of line,
ID and Fire Alarm circuits. They can
also be used to attenuate RFI on DC
Access Control circuits. The filter
offers virtually no resistance to DC
circuits, but will substantially
attenuate RFI signals between
2.5MHz -800MHz making them
quicker and more cost effective than
rewiring in screened cable.
Technical Specification
Dimensions: 41.5H x 11W x 4D
mm
Product Code
3141 ACT 2468 Radio
Frequency Filter
24V Slave Relay double pole
changeover relay.
Product Code
609.001.015
Hoyles S312N double pole interface
relay. This device accepts a variety of
input conditions (Voltage, Logic,
Closed Circuit and Open Circuit) for
interfacing various signals via voltage
free DPCO contacts.
With a self adhesive backing for easy
mounting. Four mounting holes are
also provided for more permanent
fixing.
Product Code
6504
Hoyles S312T double pole interface
relay. This device accepts a variety of
input conditions (Voltage, Logic,
Closed Circuit and Open Circuit) for
interfacing various signals via voltage
DPCO contacts.
The S312T is similar to the S312N but
its action can be delayed by up to
about 30 seconds. This can be
adjusted with the on board
potentiometer. This can be a useful
feature where it is necessary to delay
one action slightly to allow another.
It is supplied with a self adhesive
backing for easy mounting. Four
mounting holes are also provided for
more permanent fixing.
Product Code
609.001.214
Hoyles S320 interface relay . This
device accepts a variety of input
conditions for interfacing various
signals (Voltage, Logic, Closed Circuit
and Open Circuit). Output via voltage
free SPCO contacts.
With a self adhesive back for easy
mounting.
Product Code
6698
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 5
Chapter 1 - Accessories
Intruder Catalogue Chapter 1 Page 6 03/12
12V Slave Relay double pole
changeover relay.
Product Code
609.001.014
Elmdene Multipurpose Relay.
MPR001 MULTI-PURPOSE RELAY
Supply 12-13.8Vdc
Current 20mA
Trigger Input 1.5mA
Switch Load Maximum 1A@ 24V dc
or 0.5A @ 125V ac
Dimensions 72Lx26Wx20D Product Code
609.001.215
Contacted Locks
A diecast metal box measuring
90H x 38W x 30D mm containing a
keyswitch and anti-tamper switch.
Brown. Boxed Outside Shunt D.C.
Product Code
4015 Lock
Document Box
Plastic folder for the inside of control
panel lids. For fitting adjacent to
control panels to keep system
information secure.
Product Codes
9313 Document Box
(Keyed Alike)
9314 Key For Document
Box
Window Stickers
Window Sticker Reads "Secured by
ADT Fire and Security 24 Hour Alarm
Monitoring" (174mm x 60mm)
Surface Sticker Reads "Secured by
ADT Fire and Security 24 Hour Alarm
Monitoring" (174mm x 60mm)
Product Codes
604.002.183 Window Sticker
604.002.186 Surface Sticker
Strobes
These high quality range of Xenon
Beacons are tested to IP65 making
them ideal for most stringent
applications.
Each beacon incorporates a low
profile Frestral lens designed to give
maximum light output.
Features
. Protected to IP65
. Attractive Low Profile
Technical Specification
Design
Dimensions: 75 Dia x 51Hmm
Product Codes
7174 Clear strobe 12V
1W
7464 Blue strobe 12V
1W
7609 Amber strobe 12V
1W
Chubb 3G11O D/C. Is a BS3621 5
Detainer Mortice lock complete with
73mm backset, SPDS single pole
changeover switch, DPDS Double
pole changeover switch.
Product Codes
4001-ICS Chubb 3G110
D/C lock
4049-ICS Chubb 3G114
D/C lock
Relays
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 6
Chapter 1 - Accessories
Intruder Catalogue Chapter 1 Page 7 03/12
The Minitran 452 is a new low cost
Telephone Test Set designed to
enable alarm technicians to test lines
and verify signals sent to the Alarm
Receiving Centre during
commissioning and maintenance
inspections. The tester has Talk and
Monitor modes to enable lines to be
tested without disrupting signals. The
tester also incudes DSP (Digital
Service Protection) which enables
safe operation where telephone wiring
may carry digital signals, hazardous
voltages or fault conditions. A POL
test button with Green/Red LEDs
indicates correct or reverse A/B
polarity connection.
The tester comes complete with easy
to use operating instructions and line
cable with Red/Black Crock-Clip
connectors.
Features
DSP Digital Services Protection
Safe with Data Lines
Rugged Drop Proof Design
Protected against 230 VAC
Flat Battery - always ready feature
Over Current Protection
Battery Saving Auto Power-off
Lightning Surge Protection
Three Position Volume Boost
Finger Tip Microphone Mute
Headset Socket for Hands Free
32 Digit Last Number Redial
Acoustic Shock Protection
Product Code
M0452-00 Minitran 452 test
Telephone
Handset
Minitran 452 Test Telephone Handset
Service Tools
Service & installations engineer products, each designed to enable engineers to provide a trouble free alarm installation
service.*
GOLD-PLUS is an Intelligent Battery
Capacity Tester designed to test
6/12V lead acid batteries from 1.2Ah
to 100Ah. Its pulse load technology
simulates a 20 hour battery discharge
test in just 20 seconds, displaying the
Ampere-hour (Ah) capacity available
in the battery.
Displays the Ah capacity available
in 6/12Volt lead acid batteries in
seconds
Tests 6Volt SLA batteries from
1.2Ah to 12Ah and 12Volt from
1.2Ah to 100Ah
Tests SLA batteries straight from
the box, partially or fully charged
Can be calibrated to test Standby
SLA and Cyclic GEL batteries.
Table indicates when batteries
should be recharged or replaced
Quick, accurate and easy to use
Product Code
GOLD-PLUS ACT Gold-plus
Battery SLA
Tester
GOLDPLUS Battery SLA Tester
The NEW AVO300 from ACT Meters
provides a high resolution 4000 count
digital display and offers a range of
measurement modes for AC and DC
applications, resistance and current
measurement. The AVO300 also has
the added benefit of a separate
battery and fuse compartment,
meaning both battery and fuses can
be replaced without opening the main
instrument body and breaking/
invalidating the calibration seal
Fully auto-ranging 4000 count
digital display
Separate fuse and battery
compartment, allows both to be
replaced without breaking the
calibration seals
Tough rubber-armoured case
Product Code
ACT-AVO300 ACT Autoranging
Digital Meter
ACT-AVO300 ACT Autoranging Digital Meter
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 7
Chapter 1 - Accessories
Intruder Catalogue Chapter 1 Page 8 03/12
This page is left intentionally blank.
Intruder_Ch1_Accesories:Layout 1 20/03/2012 09:33 Page 8
Intruder Catalogue Chapter 2 Page 1
Chapter 2 - Audio Verification
03/12
CSL Audio Verification Unit
The CS5000 Is a compact AVU designed to provide
confirmation of an unauthorised intruder presence. The
system comprises a small, low current control unit housed in
the same enclosure as the alarm panel. It has two
independent microphone inputs with an auto-learn feature
that enables it to be easily connected to the majority of
control panels.
The unit also has clean changeover relay contacts to silence
the internal alarm siren whether recording or transmitting
unauthorised sounds. Microphones are housed in a small
plastic case that can be surface or corner mounted and
each has a two-wire connection designed to operate over
long lengths of standard alarm cable without suffering from
interference.
Features
The audio verification unit is small enough to be fitted
inside most panel housings
Up to 512 microphones can be fitted using full allowance
of expansion boards and hubs
Each microphone has an automatic gain compensation to
counter noise swamping offering High intelligibility audio
Microphone modules will operate on 1Km loop lengths of
ordinary alarm cable
Microphone tamper contacts for anti tamper monitoring
Individual microphone module audio level and recording
indicators
Four 10 second pre-recorded messages can be played
back for user prompting (with expander)
Relay output for controlling internal sirens and
programmable outputs
CSL CS5000-00 Audio Verification
Interface (PCB Only)
Product Code
608.009.192
CSL CS5010-00 Audio Verification
Microphone (up to 8 per standard
system)
Product Code
608.009.193
CSL CS5020-00 Expansion Board for
CSL Audio Interface (608.009.192) to
allow connection of further 24
Microphones over 6 additional
busses-32 total.
Also includes Voice annunciation
features for the reduction of User
False Alarms
Product Code
608.009.194
CS5030 AVU LIM/Hub Expansion
Board
Product Code
608.009.195
LIM/Hub Expansion Board
Audio Verification
CSL Audio Verification Interface
CSL Audio Verification Microphone
CSL Expansion Board
Audio Verification
The basis of Audio Confirmation is to enable an Alarm Receiving Centre operator to listen in to a premises that has
signalled an alarm activation and allow the ARC operator to confirm if the alarm activation is genuine.
Confirmation of intruder alarm activations is now a requirement under the ACPO 2000 Security Systems Policy. This can be
done through sequential, audio or visual confirmation.
Intruder_Ch2_AudioVerif:Layout 1 20/03/2012 09:36 Page 1
Chapter 2 - Audio Verification
Intruder Catalogue Chapter 2 Page 2 03/12
This page is left intentionally blank.
Intruder_Ch2_AudioVerif:Layout 1 20/03/2012 09:36 Page 2
Intruder Catalogue Chapter 3 Page 1
Chapter 3 - Batteries
Batteries
03/12
Product Codes
Product Code Voltage Autonomy Dimensions Weight (kg)
CS0388 12V 0.6Ah 110 x 90 x 28mm 0.18
PS-1212 12V 1.2Ah 97 x 42 x 54mm 0.55
PS-1221 12V 2.1Ah 178 x 34 x 66mm 1.0
PS-1230 12V 3.0Ah 134 x 67 x 66mm 1.2
PS-1242 12V 4.2Ah 90 x 70 x 101mm 1.7
PS-1270 12V 7.2Ah 151 x 65 x 98mm 2.6
PS-12120 12V 12.0Ah 151 x 98 x 100mm 4.1
PS-12170 12V 17.0Ah 181 x 76 x 167mm 6.1
PS-12260 12V 26.0Ah 167 x 175 x 125mm 9.4
PS-122380 12V 38.0Ah 197 x 165 x 170mm 13.8
PS-12650 12V 65.0Ah 348 x 167 x 178mm 24.0
PS-6100 6V 10.0Ah 151 x 51 x 98mm 2.1
Product Code Battery
660.002.028 Alkaline 6V Battery (GP1412AP)
TY-4103-F2 Varta Alkaline (1.5V/1350mAh) Battery: Size AAA
TY-4106-F2 Varta Alkaline (1.5V/3200mAh) Battery: Size AA
TY-4122-F1 Varta Alkaline (9V/600mAh) Battery: Size E
TY-6205-BL1 Flint CR123A lithium battery 2/3 A,
TY-GP910A-BL2 Gold Peak Alkaline (1.5V/0mAh) Battery; Size N
TY-CR2025-BL5 Gold Peak LI-MNO2 CR2025 3V
TY-CR2032-BL5 Gold Peak LI-MNO2 CR2032 3V
AP-1 IBP Battery bundle for smoke
AP6MTHS IPB old dye pack batteries
B-02-8001 ETS replacement battery
L91 L91 Lithium AA 1.5v Battery
CS0388 CSL Dualcom replacement batt
DOM-BAT-CRI HON DOM ADT 4VOLT 3.5AHR batt
LED-BATTERY-PACK ELM battery for LED module
Q3-BATT-SET IBP Q3 Battery
Q3MAINTKIT IBP Q3 Battery Set
7K67J Duracell 7K67J for EMS PA
CR2450 3v Coin Cell Battery
LSH20 3.6v 13Ah Saft Battery (for Optex RF Beams)
We supply a wide range of rechargable lead acid batteries to meet the needs of giving extra autonomy to your security
system.
Intruder_Ch3_Batteries:Layout 1 20/03/2012 09:43 Page 1
Chapter 3 - Batteries
Intruder Catalogue Chapter 3 Page 2 03/12
This page is left intentionally blank.
Intruder_Ch3_Batteries:Layout 1 20/03/2012 09:43 Page 2
Intruder Catalogue Chapter 4 Page 1
Chapter 4 - Contacts
03/12
Contacts (Magnetic)
Contacts offer a simple means of protecting doors, windows and roller shutters. The principle of operation is that one
element, (usually fixed to the non-moving section), contains a small switch encapsulated in a glass bottle, (called a
magnetic reed), and the other elements contain a magnet.
When the magnet is held within the operating gap of the magnetic reed, the switch is held closed and the circuit made. If the
magnet is moved outside the operating gap parameters, the circuit opens and an alarm is generated. Tyco Safety Products
stock a wide variety of contact to suit most applications.
EN50131 -2-6 Opening Contacts (Magnetic)
Changes are necessary due to the new EN standards
implementation of, Draft prEN 50131-2-6 Alarm systems -
Intrusion and hold-up systems Part 2-6: Opening contacts
(magnetic) that came into force back in April 2007, but this
was not adhered too due to their being a lack of different
types available and their reliability.
Major Change to grade 3
4.5.4 Magnetic field interference
When the detector is mounted in accordance with the
manufacturer's instructions and is subject to the presence of
an external magnetic field generated by the interference of
an external magnet and applied to the faces of the detector,
the detector shall either:
A) Be immune to any influence by the interference of the
magnet and continue to operate normally.
B) Generate an intrusion, and/or tamper, and/or fault, and/or
other independent signal or message in accordance with
the standard when the make or break distances exceed
twice those specified.
EN3-QFC-GN
White 20mm Plastic Flush, Cabled
Contact for use on Wood or
Aluminium. Integral Resistors, for use
in FSL or DP systems, single or
multiple doors. Incorporating
magnetic detection/immunity.
Product Code
EN3-QFC-GN
White 20mm Plastic Flush, Cabled
Contact for use on Wood or
Aluminium.
EN3-QFC-BN-GN
Brown 20mm Plastic Flush, Cabled
Contact for use on Wood or
Aluminium. Integral Resistors, for use
in FSL or DP systems, single or
multiple doors. Incorporating
magnetic detection/immunity.
Product Code
EN3-QFC-BN-GN
Brown 20mm Plastic Flush, Cabled
Contact for use on Wood or
Aluminium.
Flush Contacts - Grade 3
Surface Contacts - Grade 3
EN3-QSC-GN
Small white Surface Plastic, Contact
for use on Wood or Aluminium.
Integral Resistors, for use in FSL or
DP systems, single or multiple doors.
Incorporating magnetic
detection/immunity.
Product Code
EN3-QSC-GN
Small white Surface Plastic, Contact
for use on Wood or Aluminium.
EN3-QSC-BN-GN
Small Brown Surface Plastic, Contact
for use on Wood or Aluminium.
Integral Resistors, for use in FSL or
DP systems, single or multiple doors.
Incorporating magnetic
detection/immunity.
Product Code
EN3-QSC-BN-GN
Small Brown Surface Plastic, Contact
for use on Wood or Aluminium
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 1
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 2 03/12
EN3-LSC-GN
Large white Surface Plastic, Cabled
Contact for use on Wood or
Aluminium. Integral Resistors, for use
in FSL or DP systems, single or
multiple doors. Incorporating
magnetic detection/immunity.
Product Code
EN3-LSC-GN
Large white Surface Plastic,
Cabled Contact for use on
Wood or Aluminium.
EN3-LSC-BN-GN
Large brown Surface Plastic, Cabled
Contact for use on Wood or
Aluminium. Integral Resistors, for use
in FSL or DP systems, single or
multiple doors. Incorporating
magnetic detection/immunity.
Product Code
EN3-LSC-BN-GN
Large brown Surface Plastic,
Cabled Contact for use on
Wood or Aluminium.
Surface Contacts - Grade 3 contd
EN3-RSA-GN
Roller Shutter Contact, Integral
Resistors, for use in FSL or DP
systems, single or multiple doors.
Incorporating magnetic
detection/immunity.
Product Code
EN3-RSA-GN
Roller Shutter Contact
Heavy Duty service Aliminium
Contact with 8 Terminals and 1K
Resistor.
Product Code
YM101KR
YM101KR
Large white surface contact with 6
Term and selectable EOL
resistor values and tampers
Product Code
SC570-WH-MD-MULTI-G3
SC570-WH-MD-MULTI-G3
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 2
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 3 03/12
LSC-SPC-BN
4HD-SPC
4SM-SPC
S-SPC
QSC-SPC QSC-SPC-BN
LSC-SPC
Spacers
These spacers will help in aligning up the magnet to reed
contact on doors that are off set or need a small amount of
levelling up. The spacers can be used on both the magnet
and or the door contact.
There are 5 different types to suit most of the surface range
and in Aluminium, brown and white versions.
Features
White, brown and Aluminium versions
3mm and 2.5mm sizes
Can be used on contact or magnet
Product Codes
S-SPC 3.0MM Spacer for use with S type
Contacts, 6S-GN
4HD-SPC 3.0MM Spacer for use with HD type
Contacts, 6HDSO-GN
4SM-SPC 3.0MM Spacer for use with SM type
Contacts, 6SM-GN
LSC-SPC Pack of 5, 2.5MM Spacers for LST-GN
& EN3-LSC-GN Contacts
LSC-SPC-BN Pack of 5, 2.5MM Brown Spacers for
EN3-LSC-BN-GN Contact
QSC-SPC Pack of 5, 2.5MM Spacers for QSC-GN
& EN3-QSC-GN Contacts
QSC-SPC-BN Pack of 5, 2.5MM Brown Spacers for
EN3-QSC-BN-GN Contact
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 3
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 4 03/12
Grade 3 Specifications
Flush Surface
Grade 3 3 3 3
Model EN3-QFC-GN EN3-QSC-GN EN3-LSC-GN EN3-RSA-GN
EN3-QFC-BN-GN EN3-QSC-BN-GN EN3-LSC-BN-GN
Application
Cabled/Terminals Cabled Cabled Cabled Cabled
Suitable for Wood or Metal Wood or Metal Wood or Metal Wood or Metal Wood or Metal
Fixing Screws Screws Screws Screws
Operation Mode FSL of DP FSL of DP FSL of DP FSL of DP
Single/Multiple Doors Single or Multiple Single or Multiple Single or Multiple Single or Multiple
Special Features Magnetic Magnetic Magnetic Magnetic
Immunity Immunity Immunity Immunity & Detection
Material ABS ABS ABS Aluminium
Colour White or White or White or Silver
Brown Brown Brown
Contact Details
Magnetic Detection/Immunity Immunity Immunity Immunity Detection
Operating Gap-
Minimum Close (mm) 13 9 7 22
Resistors Fitted Yes Yes Yes Yes
Number of Wires or Terminals 6W 6W 6W 6W
S/Steel Cable protection No No 50cm
Encapsulation Potted Potted Potted Potted
Contact Dimensions
& Fixings
Length (mm) N/A 70 93 150
Width (mm) N/A 17 25 40
Depth (mm) 15 15 25 14
Flange (mm) 36 x 22.5 N/A N/A N/A
Body Diameter (mm) 20 N/A N/A N/A
Cable Length (mm) 100 100 100 100
Fixings Screws Screws Screws Screws
Magnetic Details
Length (mm) N/A 70 93 73
Width (mm) N/A 17 25 60
Depth (mm) 25 15 25 40
Flange (mm) 36 x 22.5 N/A N/A N/A
Body Diameter (mm) 20 N/A N/A N/A
Fixings Screws Screws Screws Screws
Classification
TS50131-2-6 Grade 3 3 3 3
Environmental Class III III III III
Protection IP67 IP67 IP67 IP67
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 4
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 5 03/12
Medium surface contact designed to
work on large wooden or metal
doors.
Product Code
6SL-GN
Medium surface contact designed to
work on large wooden or metal
doors, 2 m of cable provided.
Product Code
6SL-200-GN
Small metal surface fitting unit
designed to work on wooden or metal
doors.
Product Code
6SM-GN
Small surface fitting unit designed to
work on wooden or metal doors.
Product Code
6S-GN
Large size surface fitting unit with
terminals, designed to work on
wooden or metal doors.
Product Code
LST-GN
6SL-GN
Medium surface contact designed to
work on large wooden or metal
doors. Available in brown only.
Product Code
6SL-200-BN-GN
Medium surface contact designed to
work on large wooden or metal
doors. Available in brown only.
Product Code
6SL-BN-GN
6SL-BN-GN
Surface Contacts - Grade 2
6S-GN
6SM-GN
LST-GN
6SL-200-GN
6SL-200-BN-GN
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 5
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 6 03/12
Large surface contact designed to
work on large or metal doors.
Product Code
6PHD-GN
Large surface contact designed to
work on large or metal doors, has
built in standoff.
Product Code
6HDSO-GN
6HDSO-GN
Heavy duty unit aluminium with 8
terminals.
Product Code
VHDA-GN
VHDA-GN
6PHD-GN
QST-GN
Medium surface contact designed to
work on large wooden or metal
doors.
Product Code
QST-GN
Medium surface contact designed to
work on large wooden or metal
doors. Available in brown only.
Product Code
QST-BN-GN
QST-BN-GN
Large surface contact designed to
work on large wooden or metal
doors.
Product Code
6HD-GN-SS
6HD-GN-SS
Large Roller shutter contact designed
to work on large wooden or metal
roller shutter doors.
Note: Non-handed.
Direct replacement for old part number 1019.
Product Code
6RSA-100-GN
Small roller shutter contact designed
to work on large wooden or metal
doors.
Note: Non-handed Product Code
6RSL-100-GN
6RSL-100-GN
6RSA-100-GN
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 6
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 7
03/12
A small white flush fitting unit
designed to work on wooden doors,
6 terminals with tamper cover.
Product Code
QFT-GN
A Pencil type flush fitting unit
designed to work on wooden doors.
Product Code
6F-GN
A small flush fitting unit designed to
work on wooden doors.
Product Code
6QFC-GN
A small flush fitting unit designed to
work on wooden doors. Available in
brown only.
Product Code
6QFC-BN-GN
Flush Contacts - Grade 2
Large flush fitting unit designed to
work on wooden or metal doors.
Product Code
6MDP-GN
6F-GN
6QFC-GN
6QFC-BN-GN
QFT-GN
6MDP-GN
A small brown flush fitting unit
designed to work on wooden doors,
6 terminals with tamper cover.
Product Code
QFT-BN-GN
QFT-BN-GN
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 7
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 8 03/12
High Security flush fitting contact with
cable, designed to work on wooden
or metal doors.
Product Code
6VS105-GN
Large Roller shutter contact designed
to work on large wooden or metal
roller shutter doors.
Note: This is a handed model and must not be
confused with the basic model 6RSA-100-GN.
The contact would be fitted to the LEFT side of
a roller shutter door when stood inside the
building looking towards the outside.
For the version to fit to the RIGHT side of a
roller shutter door when stood inside the
building looking towards the outside, part code
would be 6VS222-GN-REV available as an NSL
from Elmdene.
Product Code
6VS222-GN
Large surface contact designed to
work on large wooden or metal
doors.
Product Code
6VS302-GN
High Security flush fitting contact with
cable, designed to work on wooden
or metal doors.
Product Code
6FMBR-GN
Large surface contact designed to
work on large wooden or metal
doors, has built in standoff.
Product Code
6HDBR-SO-GN
* NOTE: Please see the following pages of charts for more detailed information regarding the above contacts.
6FMBR-GN
6VS105-GN
6HDBR-SO-GN
High Security - Grade 2
6VS222-GN
6VS302-GN
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 8
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 9 03/12
Grade 2 2 2 2 2 2
Model 6S-GN 6SM-GN LST-GN 6SL-200-GN 6SL -GN QST-GN
6SL-200-BN-GN 6SL-BN-GN QST-BN-GN
Application Small surface fitting Small metal surface Medium size fitting Medium surface Medium surface Medium surface contact
unit designed to fitting unit designed unit with terminals contact designed contact designed designed to work
work on wooden to work on wooden designed to work to work on large to work on large on large wooden
or metal doors or metal doors on wooden or wooden or wooden or or metal doors
metal doors metal doors metal doors
Material ABS Anodised ABS ABS ABS ABS
Colours White Silver White White or Brown White or Brown White or Brown
Contact Length 38mm 38mm 86mm 65mm 65mm 67mm
Width 14mm 16mm 25mm 12mm 12mm 14mm
Depth 8.5mm 9.5mm 20mm 12mm 12mm 13mm
Magnet Length 38mm 38mm 86mm 65mm 65mm 67mm
Width 14mm 16mm 25mm 12mm 12mm 14mm
Depth 8.5mm 9.5mm 20mm 12mm 12mm 13mm
Reed Type Standard Standard Standard Standard Standard Standard
No. of Reeds 1 1 1 1 1 1
Operating Gap-
max 25mm 15mm 40mm 15mm 15mm 20mm
Encapsulation Potted Potted 6 Terminals Potted Potted Terminals
Protection IP67 IP67 N/A IP67 IP67 IP43
Amount of
Cable wires 6 6 0 6 6 Terminals
Cable Length 1m 1m 6 Terminals 2m 1m N/A
Cable Protection
S/Steel No No N/A No No No
2 x 1K/1K for EOL
EN50131/ EOL EOL EOL EOL EOL EOL
PD6662 grade 2 2 2 2 2 2
Grade 2 2 2 2 2
Model 6PHD-GN 6HDSO-GN VHDA-GN 6RSL-100-GN 6RSA-GN
Application Large surface contact to Small metal surface Heavy duty Ali Small Roller Shutter Large Roller Shutter
to work on large wooden fitting unit designed with 8 Terminal contact designed to contact designed
or metal doors to work on wooden work on large to work on large
or metal doors, has wooden or metal doors wooden or metal doors
built in standoff
Material ABS Anodised ABS ABS ABS
Colours White Silver Silver Silver Silver
Contact Length 80mm 80mm 170mm 94mm 175mm
Width 20mm 32mm 25mm 40mm 52mm
Depth 12mm 45mm 25mm 15mm 15mm
Magnet Length 80mm 80mm 170mm 50mm 85mm
Width 20mm 32mm 25mm 55mm 70mm
Depth 12mm 45mm 25mm 35mm 35mm
Reed Type Standard Standard Standard Standard Standard
No. of Reeds 1 1 1 1 1
Operating Gap-max 15mm 25mm 50mm 70mm 70mm
Encapsulation Potted Potted terminals Potted Potted
Protection IP67 IP67 N/A IP67 IP67
Amount of
Cable wires 6 6 0 6 6
Cable Length 1m 1m 8 Terminals 1m 1m
Cable Protection
S/Steel No Option Yes 50cm 50cm
2 x 1K/1K for EOL
EN50131/ EOL EOL EOL EOL EOL
PD6662 grade 2 2 2 2 2
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 9
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 10 03/12
Grade 2 2 2 2
Model 6F-GN 6QFC--GN QFT-GN 6MDP-GN
6QFC-BN-GN QFT-BN-GN
Application A Pencil type flush A small flush fitting A small flush fitting unit Large flush fitting unit
fitting unit designed unit designed to designed to work on designed to work on
to work on wooden work on wooden or wooden doors 6 terminals wooden or metal doors
or metal doors metal doors with tamper cover
Material ABS ABS ABS ABS
Colours White White or Brown White or Brown White
Contact Length 34mm 15mm 15mm 34mm
Diameter Flange 8mm 36mm x 22.5mm 36mm x 22.5mm 38mm (Oval)
Diameter standoff
Flange N/A 0mm 0mm 24mm
Diameter Body 8mm 20mm 20mm 12mm
Fixings Push In 2 Screws 2 Screws 2 Screws
Magnet Length 34mm 15mm 15mm 34mm
Diameter Flange 8mm 36mm x 22.5mm 36mm x 22.5mm 38mm (Oval)
Diameter standoff
Flange N/A 0mm 0mm 24mm
Diameter Body 8mm 20mm 20mm 12mm
Fixings Push In 2 Screws 2 Screws 2 Screws
Reed Type Standard Standard Standard Standard
No. of Reeds 1 1 1 1
Operating Gap 10mm 18mm 18mm 7mm
max
Encapsulation Potted Potted Terminals Potted
Protection No No No No
Amount of cable
wires 6 6 2 6
Cable Length 1m 1m Terminals 1m
Cable Protection No No No No
2 x 1K/1K for EOL EOL EOL EOL EOL
EN50131/
PD6662 grade 2 2 2 2
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 10
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 11 03/12
FLush Contacts - Grade 1(Service Use Only)
A small brown flush fitting contact
designed to fit on wooden doors
5 x terminals.
Product Code
QF-5-BN
A small white flush fitting contact
designed to fit on wooden doors
5 x terminals.
Product Code
QF-5
QF-5
QF-5-BN
Grade 1
Model QF-5
QF-5-BN
Application A Small flush fitting
contact with 5
terminals and no
resistors to work on
wooden doors
Material ABS
Colours White or Brow
Contact Length 15mm
Diameter Flange 36mm x 22.5mm
Diameter standoff
Flange 0mm
Diameter Body 20mm
Fixings 2 Screws
Magnet Length 15mm
Diameter Flange 36mm x 22.5mm
Diameter standoff
Flange 0mm
Diameter Body 20mm
Fixings 2 Screws
Reed Type Standard
No. of Reeds 1
Operating Gap 18mm
max
Encapsulation N/A
Protection No
Amount of cable
wires 0
Cable Length 0
Cable Protection No
2 x 1K/1K for EOL No
EN50131/
PD6662 grade 1
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 11
Chapter 4 - Contacts
Intruder Catalogue Chapter 4 Page 12 03/12
This page is left intentionally blank.
Intruder_Ch4_Contacts:Layout 1 20/03/2012 09:47 Page 12
Intruder Catalogue Chapter 5 Page 1
Chapter 5 - Day Alarms
03/12
Hoyles Exitguard
This new EXITGUARD uses a nine digit keypad for both
control and programming. The tone of the high power
integral alarm can be selected to distinguish it from other
alarms. The alarm can be silenced and reset using a four
digit code or the EXITGUARD can re-arm automatically after
a preset delay once the door has been closed. Separate
Door Open Too Long (DOTL) delays can be set for Code
Reset and Auto Reset modes. There is also a Bleep In Off
option and Chime facility. There are a number of different
models to suit various applications:
EX204 is battery powered for use where a separate supply
of power is not available and the protected door is opened
infrequently or there is no requirement to sound the integral
sounder for long periods. If necessary the integral battery
can be dispensed with and a separate 12vdc supply
provided. This version has a logic output signal for
connection to a MULTIGUARD indicator.
EX205 is 12vdc powered for use where the protected door
may be opened frequently or the integral sounder may need
to sound for long periods. This version can also be used as
equipment.
There is a logic output signal for connection to a
MULTIGUARD and there are volt free relay contacts for
separately signalling ON/OFF status and alarm conditions at
remote points. This version cannot be powered from
batteries. EX206 is 230vac mains powered where the
protected door may be opened frequently or the sounder
may need to sound for long periods. There is a logic output
signal for connection to a MULTIGUARD and a volt free relay
contact for alarm condition.
This version is also supplied with 6 x AA alkaline batteries for
standby - Note: the batteries will not power the alarm relay.
All are supplied with a surface mounting door contact, fixing
screws and a door warning label.
Fire Door Checker
This unique feature enables the EXITGUARD to be used
to verify that all emergency fire exit doors are available for
use when a building is occupied. Simply wire a switched
signal from the intruder alarm control of the building to each
EXITGUARD. As soon as the alarm is switched off when the
building is opened staff are forced to visit each fire door in
turn and release the door to ensure that it is ready for
emergency use. The normal EXITGUARD functions are then
automatically restored to give protection against
un-authorised exit.
Features
High Power Piezo Sounder
Keypad Control
Auto Reset / Re-arm Delays 0 - 88s
Separate Door Open Too Long Delays for
Keypad & Auto re-arm. 0s - 88s
Bleep In Off option
Front & Back Acting Tamper Switch
Battery, 12 Vdc & Mains Versions
Selectable Alarm Tones
Visual Alarm Indication
Chime Facility
Alarm Relay Output
On - Off Monitor Relay
Fire Door Checker
Day Alarms
EXITGUARD is the ideal solution for security of fire exit doors in Supermarkets, Hotels, Restaurants, Warehouses, Leisure
Centres and all types of public buildings. It satisfies the requirements of both fire and security officers.
An integral high power sounder is activated when the door is opened to warn those in the vicinity that security has been
breached.
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 1
Chapter 5 - Day Alarms
Intruder Catalogue Chapter 5 Page 2 03/12
Specification EX204 EX205 EX206
Supply Voltage 9vdc -15Vdc 11 - 14vdc 220/240Vac
Supply Current 35A quiescent 45mA quiescent < 0.5A
80mA max 155max
Battery 6 x AA Alkaline None 6 x AA Alkaline
Fusing None None 1A BS1662 Mains fuse
Visual Indication 5 Status LEDs 5 x Status LEDs Red, 1 x Power LED Green
Status LEDs strobe with sounder on alarm on all models
Integral Sounder Level 102 - 104 db at 1 metre dependant on input voltage
Four programmable tones, two loud, two quiet
Input All models: Double pole four wire. Alarm loop and tamper loop.
Remote Input for FDC Apply +ve signal when building is closed remove when occupied for fire
door verification
Bleep in Off Programmable on all models. Disabled on factory default
MULTIGUARD O/P All models normally Logic Hi, Logic Lo on alarm
Tamper Normally closed back & front acting tamper switch all models
Alarm Relay Contacts None SPCO 1A 30Vdc for connection to remote devices
On / Off Monitoring Relay None SPCO 1A 30Vdc None
Auto Reset Timer Programmable 0 - 88secs all models
Door Open Too Long
Timer Programmable 0 - 88secs all models
Enclosures Custom designed ABS plastic back box with mark resistant decal
Door Contact Surface mount magnetic reed contact with 1m 4 core cable.
Exitguard 24hr Door Alarm & Fire Door Checker
Fire Door Checking Facility This unique feature enables the
EXITGUARD to be used to verify that all emergency fire exit
doors are available for use when a building is occupied. This
can be achieved in one of two ways, either: A. Wire a
switched 12Vdc +ve signal from the intruder alarm control
of the building to each EXITGUARD. or B. Wire a switched
12vdc +ve signal from a time clock to each EXITGUARD.
Whenever the alarm is switched off or when the time clock
removes the signal, the EXITGUARD will emit a double bleep
every 90 seconds and the LEDs will strobe. Staff must visit
each fire door in turn and release the door to ensure that it is
ready for emergency use. The normal EXITGUARD functions
are then automatically restored to give protection against
un-authorised exit. To conserve battery life it is
recommended that the EXITGUARD is centrally powered as
shown below.
Technical Specification
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 2
Chapter 5 - Day Alarms
Intruder Catalogue Chapter 5 Page 3 03/12
Exitguard 24hr Door Alarm & Fire Door Checker
Fire Door Checking Facility
This unique feature enables the EXITGUARD to be used to
verify that all emergency fire exit doors are available for use
when a building is occupied. This can be achieved in one of
two ways, either:
A. Wire a switched 12vdc +ve signal from the intruder alarm
control of the building to each EXITGUARD. or B. Wire a
switched 12vdc +ve signal from a time clock to each
EXITGUARD.
Whenever the alarm is switched off or when the time clock
removes the signal, the EXITGUARD will emit a double
bleep every 90 seconds and the LEDs will strobe. Staff must
visit each fire door in turn and release the door to ensure
that it is ready for emergency use.
The normal EXITGUARD functions are then automatically
restored to give protection against un-authorised exit. To
conserve battery life it is recommended that the
EXITGUARD is centrally powered as shown below.
Product Codes
EX204 9vdc -15Vdc Hoyles Exit Guard
EX205 11 - 14Vdc Hoyles Exit Guard
EX206 220/240VacHoyles Exit Guard
Method A
Fire Door 2
Storeroom
Door
12vdc supply. This can be a separate supply
but the-ve should be common for both
When the intruder control is armed a 12vdc+ve
is applied to the R terminal of each EXIT-
GUARD.
Fire Door 1
- + s
Intruder
Control
Fire Door 3
Fire Door 4
A 12 vdc+ve signal of at least 1 second dura-
tion is applied to the R terminal of each EXIT-
GUARD at suitable time intervals. This would
usually be at least daily, possibly twice daily.
Most time clocks with independent voltage free
clean contact would be suitable.
12 vdc
Power -
Supply +
240vac supply
240vac supply
Fire Door 2
Fire Door 1 Fire Door 3
Fire Door 4
Method B
Storeroom
Door
System Diagram
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 3
Chapter 5 - Day Alarms
Intruder Catalogue Chapter 5 Page 4 03/12
AIDALARM A600M Mains/12vdc Powered
AIDALARM A600M Mains/12vdc Powered
This is similar to the A600B but can be used to create a
more comprehensive system with the addition of a remote
reset button, remote indicator/mute unit with separate LED
and sounder controls or overdoor light / sounder.
The A600M is fitted with a volt free output relay for
connection to a MULTIGUARD indicator or a building
management system. The A600M can be powered from
either 12 volts dc from an external power supply or from
230/240 vac mains power. There is also an option for a
rechargeable standby battery (not supplied) when powered
from the mains supply.
The integral 12 volt dc supply will provide power for external
items such as overdoor lights etc.
Features
DDA Compliant
BS8300 Compliant
High Power Piezo Sounder
12 Vdc & Mains Versions
Audible & Visual Signalling
Range of Accessories
Selectable Alarm Tones
Remote Signalling Output
Choice of Four Warning Tones
No Part B Building Regulation Conflicts
AIDALARM can also be used with REDIPRESS switch strip to enable an alarm
condition to be generated near ground level. Various other options are available
using remote indicators, overdoor lights and resets. Please contact us for more
details or visit www.hedsolutions.co.uk
Aidalarm
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 4
Chapter 5 - Day Alarms
Intruder Catalogue Chapter 5 Page 5 03/12
Product Codes
609.001.206 Hoyles Light/Sounder S1678
609.001.211 Hoyles Pullcord/LED S1600
609.001.212 Hoyles Reset Button S1608
609.001.214 Hoyles 30 SEC Timer RelayS312T
609.001.215 Multipurpose Relay
S1778SR Over door A/V unit stainless steel
609.001.312 Hoyles S1608P Reset Button S/M
A600M Hoyles mains/12VDC powered Aidalarm
6504 Hoyles S312N DBL Pole Relay
6698 Hoyles S320 SGL Pole Relay
609.001.211 Hoyles Replacement cord for S1600 pull
cord
S1609S Hoyles 2 position keyswitch on stainless
steel single gang plate
S1613S Hoyles Mushroom headed latching button
with key reset facility on stainless steel
single gang plate
S1705S Call button and LED on stainless plate
S351 Hoyles Universal timer/relay module
Technical Specification
Dimensions: H X W X D
90 x 156 x 57mm
Power: 12Vdc or 240Vac
Current: Output 200mm
Multiguard Disabled Toilet Alarm System
The AA31110D MULTIGUARD is a six zone disabled
toilet alarm system for larger buildings that need central
indication of the origin of the call. It is designed to give dual
re-assurance indication at the point of operation.
Operation
When a pull cord (S1600) is operated its LED flashes and a
local buzzer (S/1678) sounds to inform the caller that the call
has been transmitted. When the call is silenced at the panel
the flashing LED becomes steady and the local buzzer
silences to inform the caller that the call has been received
and help is on the way.
If the caller pulls the cord again the LED on the pull cord will
flash and the local buzzer sounds again. When help does
arrive the call is reset using the local (S/1608) reset button.
All LEDs and buzzers, flashing or steady, are extinguished.
An integral PSU and battery are included in the AA31110D
Multiguard.
The above schematic shows only a three zone system for
clarity. The system requirements for a six zone system are
as follows:-
1 x AA31110D per six zone system
1 x S1600 or S/1605 per toilet
1 x S1678 per toilet
1 x S1608 reset button per toilet
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 5
Chapter 5 - Day Alarms
Intruder Catalogue Chapter 5 Page 6 03/12
Multiguard
Features
Custom Design Case
Integral P.S.U. & Battery Option
Integral Piezo Sounder
Unique Labelling System
Open or Closed Circuit Inputs
D.P.C.O. Global Output Relay
Lamp Test Option
Nurse Call Version with late attendance
Emergency re-call Facility
Total Flexibility
Possible uses for the Multiguard are Perimeter Protection
Systems, Personal Attack Monitoring, Fire Exit Door
Monitoring (e.g. EXITGUARDs/AIDALARMs) and Nurse Call
Systems. There are also many other applications in the field
of process monitoring such as Deep Freeze Alarms.
Technical Specification
MG212000 & MG212100 General purpose annunciators.
These Multiguards are the basic versions used for general
purpose monitoring where zone isolation is not required.
The MG212100 is fitted with an integral 12v 250ma PSU and
standby rechargeable battery. In all other respects these two
versions are identical.
When an alarm condition is detected an audible warning is
given by the integral piezo sounder, the relevant zone LED
flashes, and a global relay energises to provide volt free
DPCO contacts for signalling to other equipment.
By pressing F1 the sounder is SILENCED, the alarm
condition is accepted, the global relay restores to normal
and the LED flashes more slowly.
When the cause of the alarm condition has been
investigated and cleared F2 can be pressed to RESET the
visual indication. If a subsequent alarm condition occurs
before earlier ones are cleared then all prior indications are
temporarily suppressed in order to emphasise the latest
event.
MG216000, MG216010 & MG216110 Annunciators with
Zone Isolate facilities. These are specified where zone
isolation facilities are required.
The operation is similar to the basic units. However, they are
fitted with six zone buttons Z1 - Z6 and, in the case of the
MG216010 & MG216110, a keyswitch. An alarm condition is
given in the same way as outlined above. In order to
SILENCE the alarm condition the relevant zone button is
pressed. When the cause of the alarm condition has been
cleared the zone button is pressed again to RESET the
indication. The zone buttons also have two further facilities,
a. to act as ISOLATE switches and b. to facilitate LAMP
TEST. Turning the keyswitch enables zone isolate. Pressing
a zone button illuminates an LED to indicate that the zone is
ISOLATED. Pressing the button again reinstates the zone.
Pressing any two zone buttons simultaneously tests each of
the LEDs in turn. If more than six zones are needed then a
number of units would be stacked together. The primary unit
would probably be an MG216110 which would support up
to 3 secondary units to expand the system capacity to 24
zones. These secondary units could be MG216000 versions
which would use the keyswitch and power supply of the
primary unit.
Hoyles Multiguards
The MULTIGUARD 2000-6 is a general purpose six zone annunciator. The enclosure design is such that virtually any
system size can be met by stacking units together.
To cater for the many different requirements of the emergency alarm market the Multiguard is supplied in a number of
different guises, each of which offers a remarkable degree of flexibility.
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 6
Chapter 5 - Day Alarms
Intruder Catalogue Chapter 5 Page 7 03/12
MG222000, MG226000 Repeaters.
It is often necessary to repeat indications at remote
locations. Each Multiguard master is equipped with a serial
output to enable data to be sent to a number of repeaters
simultaneously. Each Multiguard master with an integral
power supply can support up to three repeaters. If more
than three repeat locations are needed then an external
power supply should be used at the master. Because data is
sent out serially to the repeaters a reduced number of cable
cores are needed. If indication only is required
with no control functions then a five core cable will suffice
(an extra 3 cores are needed for each block of six zones) If
control functions are used then extra cores will be required,
(consult our technical department for details).
Multiguard repeaters are identical in appearance and user
functions to master units. Repeaters can be fitted with
keyswitches in the same way as master units for isolation or
other purposes.
MULTIGUARD Options
A keyswitch MG000010 can be added to any Multiguard not
already fitted with one. The keyswitch is a two position with
double pole changeover contacts. If a keyswitch is used for
isolation purposes then only the second pole is available for
an alternative use. This is obviously restricted to functions
that are coincidental with isolation. Two interface cards are
available to enable Multiguard annunciators to drive external
equipment. The MG020000 uses serial data from a master
unit to provide up to 16 outputs capable of switching up to
500ma per zone (subject to psu limit). Six outputs follow the
annunciator LEDs. Six further outputs switch on alarm
condition and restore on reset. Two outputs follow the
integral sounder and global relay. Two outputs are not
nominated.
These cards will fit into the Multiguard back box as shown.
Dimensions 135 x 67 x 15 (mm).
The MG030000 takes the serial data from a master unit to
provide six relay outputs with voltage free DPCO contacts
(1A/30vdc resistive). The activation of these relay outputs is
dependant upon the software configuration of the master
unit. These cards are often used to interface with CCTV
multiplexers. The cards must be housed separately. Power
requirement 12vdc 70ma. Dimensions 142 x 110 x 15 (mm)
MG311000 Nurse Call annunciators.
The principle of operation is similar to the Multiguard
general purpose annunciators. There is a SILENCE button
F1 but no reset button or isolate facilities are fitted. Integral
power supplies are NOT usually fitted to these versions as
extra power is needed for call points and overdoor lights etc.
The control logic is non-latching. When a call is made an
audible warning is given by an integral piezo sounder and
the relevant zone LED flashes. The sounder can be silenced
at the panel but must be reset at the call point.
Nurse call annunciators have facilities for Late Attendance
indication. When a late attendance condition is generated
the Multiguard emits an interrupted pulsed tone
accompanied by an interrupted flashing LED for the relevant
zone. Similar but continuous pulsed signals are used for
Emergency Re-call. Signals are graded - late attendance
takes priority over standard calls and emergency re-call take
priority over late attendance.
Manual and Electronic Call Points can be used on the
same installation. However, late attendance and emergency
re-call are only possible with electronic call points.
Nurse Call Items.
S1600P is a manual latching call point with jumbo
re-assurance LED. Pressing the button generates the call,
pressing again resets it. The latching button can also be
used to illuminate and overdoor indicator (see below).
It designed for either surface or flush mounting on a
standard single gang electrical box.
The S1663P is an advanced electronic call point capable of
standard and emergency re-call. It is also generates a late
attendance signal. Calls are also reset at these points.
Pillow
Pushes or Ceiling Pull-Cords may be connected to
Electronic Call Points. When a call is generated a late
attendance timer is activated. If the call is not attended to
and reset within a predetermined period (adjustable on
installation at each call point between 30 seconds and 2/
minutes) a late attendance alarm is generated at the panel.
An emergency re-call can be generated at any time by
pressing both the reassurance LED and the re-call
button simultaneously at the call point. An output is available
from the call point for overdoor or corridor indicators.
S1636RP is an overdoor or corridor indicator.
When used in a Multiguard nurse call system it derives its
power from either a manual or electronic call point. It is
designed for either surface or flush mounting on a standard
single gang electrical box.
EXITGUARD Self contained door alarm The EXITGUARD is
the ideal solution for the security of fire exit doors. Not only
in nursing and residential homes but also in supermarkets,
hotels, restaurants, warehouses, leisure centres and other
public buildings. It satisfies the requirements of both fire and
security officers. A number of versions are available and
they can be linked back to Multiguard annunciators. (Only
the EX500 and EX600 are suitable for nurse call
annunciators. Separate information available).
Product Codes
609.001.202 Hoyles Multiguard 6ZN MG212100
609.001.203 Hoyles Multiguard EXT MG212000
609.001.204 Hoyles Multiguard RPT MG222000
609.001.205 Hoyles Multiguard K/S
S1778PR Overdoor light and buzzer with 8 red
LEDs white plastic plate
609.001.211 S1600
S1708S Reset button on stainless steel plate
609.001.214 Hoyles 30 Sec Timer Relay S312T
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 7
Chapter 5 - Day Alarms
Intruder Catalogue Chapter 5 Page 8 03/12
Day Alarm
Complete with tamper switch, 2 or 4 wire detection circuits
the unit will operate in standby mode for 6 months and in
alarm mode for 3 hours from a fresh, dry battery.
The Day alarm is provided with a standard 2 screw
terminal magnetic contact and works on a closed loop
detection basis.
A battery test push button enables the battery to illuminate
an LED if there is still sufficient charge in the battery.
All necessary fixing screws and 8m of twin core bell flex are
provided with this unit.
Technical Specification
Dimensions: 190H x 155W x 55D mm
Battery: PP9 Dry Cell
Output: 100dBA@1m
Magnetic Contact: Normally open
Features
On/Off keylock
Battery test push Button and LED
Easy to Install
Product Code
6356 Elmdene Battery Day Alarm
Elmdene Battery Day Alarm
This unit is designed to be a completely self contained alarm unit, ideal for situations which need to be guarded when the
normal day alarm is disarmed.
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 8
Chapter 5 - Day Alarms
Intruder Catalogue Chapter 5 Page 9 03/12
Zone Omit Modules
Grade 3 passive infra red/DualTec detection devices must
be fitted with independent anti-masking and tamper
detection.
The unique design of the ZONEGUARD allows the various
'end of line' resistors for each conditions to be passed
through to the control panel unimpeded.
In this way the detectors resistors are monitored directly by
the panel. Any value of alarm resistor greater than 1k can be
used by ZONEGUARD.
In its simplest mode ZONEGUARD uses its integral
keyswitch to omit or reinstate up to two detection zones.
Other modes are available using the integral keypad or
external devices such as biometric reader or a combination
of keyswitch and keypad, this is useful where dual
responsibility is essential. Two timed entry/exit modes are
also available.
General Rules
Zones will always omit using an omit function. If any zone
has a detection condition during reinstatement, then it must
be returned to omitted state and the detection condition
cleared and then reinstated.
Features
Complies with EN50131 Grade 3
Designed for detectors with separate alarm,
anti-masking and tamper facilities
Rear acting Tamper switch/Omits two detection zones
Integral high security keyswitch 250,000+ differs
Integral 9 digit keypad 500,000 differs
Dual responsibility or combination mode gives over 300
million differs
Zone status LEDs, Fault LED
Integral piezzo sounder
Output for remote sounder, Independent zone omitted relay
Input for remote devices, keyswitches, shunt locks,
biometric readers etc..
User programmable code change/Timed entry/exit modes
Suitable for use with other detection devices e.g. door
contacts
Wiring Diagram
Zone Omit Modules
ZONEGUARD ZG800 is a Grade 3 EN50131 zone omit unit that fits between intruder detection devices and a control panel
to allow the devices to be securely and safely omitted and reinstated without generating false alarms.
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 9
Chapter 5 - Day Alarms
Intruder Catalogue Chapter 5 Page 10 03/12
Product Code
ZG800 Zone Omit Module
Operational modes
Integral keyswitch mode. (Factory default) The keyswitch
is a 7 pin tumbler with over 250,000 differs. Grade 3
requirement is for 30,000+ differs
Integral keypad mode. The integral 9 digit keypad using a
6 digit code gives over 500,000 differs. Grade 3
requirement is for 100,000 differs.
A 10 second keypad lockout is incorporated after 5
incorrect codes are entered. 'Start again' is also
incorporated if no digit is entered within 8 seconds.
Remote latching input mode, e.g. keyswitch. This would
need to be at least 30,000 differs.
Remote non-latching input mode, e.g. biometric, card
reader or similar. Modes 3 and 4 permit the ZONEGUARD
to be fitted within one of the protected zones.
Combination of integral keypad & integral keyswitch. The
9 digit keypad used with a 4 digit code and the integral
keyswitch gives over 3000 million differs. Use of a 4 digit
code is only possible in this combination mode.
This mode is useful where dual responsibility is desirable.
Timed entry/exit, integral keyswitch to execute.
Timed entry/exit, integral keypad to execute.
These last two timed entry/exit modes offer a higher degree
of security because the procedure must be completed within
a time window and the ZONEGUARD can be sited within
one of the protected zones.
Any device can be used to activate the time window, this
could be a door contact or detector. The activation device
should not be considered to be part of the intruder detection
system but simply a device to start a procedure.
The ZONEGUARD requires a supply of 12vdc. (Quiescent
120ma in omitted state 200ma peak during programming).
The non-volatile memory stores mode settings, time delays
and codes in case of power down.
Intruder_Ch5_DayAlarms:Layout 1 20/03/2012 10:12 Page 10
Intruder Catalogue Chapter 6 Page 1
Chapter 6 - Detectors Beam
03/12
Optex AX-130T/200
The AX-70/130TN Twin beam photoelectric sensors,
designed for short-range outdoor or long-range indoor
applications. Using twin beams of pulsed infrared energy,
reliable operation is possible in the worst conditions - up to
99% of the emitted radiation can be blocked by rain, fog or
falling snow and the beams will still operate.
By utilising an automatic gain control circuit, gradual
changes in signal strength caused by weather conditions
are continually monitored and the trigger level adjusted
accordingly to compensate. In addition, the unique
anti-frost design allows for trouble-free operation when the
cover is completely frosted over. The Series achieves the
IP65 high durable structure by using the rubber packing for
all conceivable points and it prevents the rain, dust, and tiny
insect getting into the unit.
AX-100/200TF is a compact photoelectric detector with the
IP65 high durability, and stable detection performance.
These features reduce false alarms drastically - caused by
outdoor severe environmental changes and provide a wide
range of applications.
AX-350/650TF Series photobeams are dual beam long-
range sensors with a host of sophisticated extra facilities.
They are ideal for larger installations where they are
capable of external ranges up to 200m. The beams offer
four site-selectable frequencies that allow them to be
stacked one above another to provide a wall of coverage.
To reduce setup and alignment time to a minimum,
AX-350/650TF units include a one-man alignment facility,
A third infrared beam sends alignment information from the
receiver to the transmitter and allows the installer to see the
status of the received signal at the transmitter.
Input voltage is between 10.5 and 30V DC giving flexibility
in system design, particularly where large sites have remote
power supplies. The AX-350/650MKIIs dual beams reduce
the potential for false activation from birds or blowing
debris.
The AX-350 & 650DHMKIII are the Worlds First Next
Generation photoelectric sensors with full digital
communication.
This new AX series delivers excellent performance in
preventing missed and false alarms, while allowing for even
easier installation which makes the whole installation
process more cost effective.
By using full digital packet communication, the new AX
series is able to transmit the address setting, cover
open/close information and the arrival level of beam power
simultaneously. The new Time Division Multiplex System
prevents any crosstalk beams when multiple beams are
installed on site or when beams are stacked. This greatly
reduces the risk of false or missed alarms, as well as
removing the need to manually choose channel settings.
The new IP65 rated casing prevents problems caused by
water or dust, while the new Anti-Frost hood cover prevents
any build-up of frost over the upper and lower beams.
Input voltage is between 10.5 and 30V DC giving flexibility
in system design, particularly where large sites have remote
power supplies.
Note: These cannot be mixed with any other beams from
the range on the same site. For more information, please
contact Optex technical department.
AX-701/130T Infrared Photoelectric
BAX-701/130T Infrared Photoelectric
Beam
Twin beam photoelectric detectors, designed for short-range
outdoor or long-range indoor applications.
Using twin beams of pulsed infrared energy, reliable
operation is possible in the worst conditions - up to 99% of
the emitted radiation can be blocked by rain, fog or falling
snow and the beams will still operate.
By utilising an automatic gain control circuit, gradual
changes in signal strength caused by weather conditions
are continually monitored and the trigger level adjusted
accordingly to compensate. In addition, the unique anti-
frost design allows for trouble-free operation when the cover
is completely frosted over.
Features
Twin Synchronised Pulsed Beams Designed
for Greater Stability
Selectable 4-Channel Beam Frequencies
Adjustable beam interruption time - long interruption time
catches an intruder but allows a small animal to pass
through
Twin beams require simultaneous interruption to create
activation
99.5% beam blocking stability
Easy installation and alignment using viewfinder for rough
alignment and voltage meter jacks for fine-tuning
Sealed optics to prevent ingress of insects and dust
Photoelectric Beam Detectors
Beam Detectors
While movement detectors detect the movement of the body in a room the following detector will monitor the entry
through a protected perimeter.
Intruder_Ch6_Detectorsbeam:Layout 1 20/03/2012 10:13 Page 1
Chapter 6 - Detectors Beam
Intruder Catalogue Chapter 6 Page 2 03/12
Technical Specification
Product Codes
AX-130T Optex External/Internal Synchronised twin
beam, 40M outside range
AX-200TF Optex External/Internal Synchronised twin
beam, 60M outside range
AX-350TF Optex External/Internal Synchronised
Photoelectric twin beam, 100M outside
range. 4 Channel frequencies
AX-650TF Optex External/Internal Synchronised
Photoelectric twin beam, 200M outside
range. 4 Channel frequencies
AX-350DHMK111 Optex External/Internal Digital
Synchronised twin beam, 100M outside
range.
AX-650DHMK111 Optex External/Internal Digital
Synchronised twin beam, 200M outside
range.
Model AX-100TF AX-200TF
Detection Method Infrared beam interrupted detection
Maximum detection range 30m 60m
Maximum arrival range 300m 600m
Interruption period Selectable between 50, 100, 250, and 500m sec.
Selectable beam frequency 4 channel
Power supply 10.5 - 28V DC
Current consumption
(transmitter + receiver) 44mA(max.) 48mA (max.)
Alarm period 2 sec. (1) nominal
Alarm output N.C./N.O. 28V DC, 0.2A (max.)
D.Q. Output N.C. 28V DC, 0.2A (max.)
Tamper switch Opens when cover is removed at 28V DC, 0.2A max.
Operating Temperature -35C to +60C Use the optional heating unit (HU-3) in conditions of -25 C or below.
Operating Humidity 95% max.
Alignment angle 90 Horizontal, 5 Vertical
Mounting Wall and pole mounting
Weight (transmitter + receiver) 700g
Housing protection (EN 00529) IP65
Indoors Outdoors
AX-130T 100m 200m
Model AX-350TF AX-650TF
Detection method Infrared Photoelectric
Range Outdoor 100m 200m
Indoor 200m 400m
Maximum arrival distance 1000m 2000m
Beam characteristics Pulsed Infrared
Selectable beam frequency 4 channel
Interruption period 50,100,250,500 msec (4 steps)
Power Supply 10.5-30VDC
Normal operation 60mA Max Normal operation 82 mA max
Current consumption T:11mA+R49mA T:13mA+R49mA
(transmitter + receiver) During optical alignment 78mA max During optical alignment 80mA max
T:11mA+R67mA T:13mA+R67mA
Alarm period 2sec(1) nominal
Alarm output Form C Relay (28VDC 0.2A max)
Tamper Switch N.C. opens when cover is removed
Operating Temperature -35C ~ +60C
Environment Humidity 96% MAX
Alignment Angle 10 VERTICAL, 90 Horizontal
Alarm memory LED indicates memory status. Selectable Negative & Positive
Environmental disqualification Form C relay operates when beam energy has been gradually reduced to abnormal level
Circuit Gradually reduced to abnormal level
Mounting Wall or Pole
Weatherproof IP54
Weight 2750g Transmitter and Receiver
Intruder_Ch6_Detectorsbeam:Layout 1 20/03/2012 10:13 Page 2
Chapter 6 - Detectors Beam
Intruder Catalogue Chapter 6 Page 3 03/12
AX-100/200TFR
The new AX-100TFR and AX-200TFR from OPTEX is a
revolution in the perimeter security industry, offering a
significant cost saving alternative to traditional hardwired
system. No trenching is required, drastically reducing
installation costs. The unit comes wireless ready with a
multifunctional back box and is compatible with most
manufactures wireless systems.
The AX-TFR series uses four 3.6V batteries with an average
lifespan of 5 years on the 100ft model and 3 years on the
200ft model.
Note: Use 2 x Honeywell DODT8M Transmitters
Features
Long battery life AX-100TFR: approx. 5 years AX-200TFR:
approx. 3 years
Easy battery replacement
Triple tamper functions
Low battery output and LED indication
Intermittent output function
Compatible with numerous wireless transmitters
Battery saving timer function for wireless transmitters
International protection IP55
Easy angle adjustment function
Beam interruption adjustment function
99% Beam blocking stability
N.C./N.O. output selection switch
4 selectable beam frequencies
Product Codes
AX-100TFR OPX 30m RF Twin Beam unit
AX-200TFR OPX 60m RF Twin Beam unit
LSH20 Battery for AX-TFR 3.6v 13Ah (SAFT)
Model AX-100TFR AX-200TFR
Range 30m 60m
Maximum arrival distance 265m 530m
Detection Method Infrared beam interruption detection
Beam frequency selection 4 channel
Interruption period Variable between 50,100, 250, 500 msec (4steps)
Power Source 3.6V 13.0 Ah: LSH20 lithium batteries manufactured by SAFT (not installed)
Transmitter: 2 units Receiver
Cuurent Draw 620A T:300A + R : 320 A 810A T:490A + R : 320 A
(at 25
o
C, 3.6 VDC) (at 25
o
C, 3.6 VDC)
Battery Life* Transmitter 5 Years 3 Years
Receiver 5 Years
Alarm output Form C-Solid State Switch: 3.6VDC, 0.01A
Alarm period 2 sec (+1) nominal
D.Q. output Form A/B-Solid State Switch: 3.6VDC, 0.01A
Low battery output Form A/B-Solid State Switch: 3.6VDC, 0.01A (Transceiver and Receiver)
Output **Tamper output for front cover Form 3.6VDC, 0.01A Activates when cover removed (Receiver removed)
Tamper output for back box Form 3.6VDC, 0.01AActivates when either back box or chassis is removed
from the installment
Alarm Indicator 1) Light on - IR Beam nor received
Indicator (Receiver) 2) Flickering Light - IR Beams not received sufficiently
3) Light off- IR Beams received
Power Power ON: ON
(Transmitter) Power OFF: OFF
Low Battery Voltage reduction:Flicker
Operating Temperature -20
0
C - +60
o
C
Operating ambient humidity 95% Max
Alignment angle + 90
o
Horizontal, + 5
o
Vertical
Mounting Indoor /Outdoor, Wall Pole/Tower mounting (Optional main unit mounting brackets
are required, when the units mount in the tower)
Weight 1600g (Total weight of transmitter + receiver excluding accessories)
International Protection IP55
Specifications and design are subject to change witout prior notice *The value is based on the condition that it is used within the ambient temperature range of 20 to 25
o
C
** The transmitter is also equipped with AX100/200 TFR (BE)
Intruder_Ch6_Detectorsbeam:Layout 1 20/03/2012 10:13 Page 3
Chapter 6 - Detectors Beam
Darwin is the new CIAS Active Infrared Barrier.
Manufactures with high quality aluminium it is very strong
and resistant, suitable for offsetting any expansion due to
temperature peaks. Its small size (22.5X23 mm) makes it
invisible when it is installed between window casings.
Its modularity makes Darwin perfect for use with different
protection systems, both indoor and outdoor. It is equipped
with self-alignment system, alarm LED and "Plug and Play"
Fixing system which makes it easy and quick to install the
device.
No line synchronism is required as each ray is recognised
through separate optical codes. This results in optical
Synchronism with different and unique identification codes
for each single beam. The alarm operation Logic is
managed by a micro-processor which automatically sets
the configuration of the beams as adjacent, crossed or
multiple according to ray interruption and speed of
interruption.
Darwin is available with two colours: Beside the classic
black is available the new colour aluminium, really hi tech in
the look and adaptable also to light coloured rooms.
Technical Specification
616.017.100 616.017.101 616.017.102 616.017.103
Indoor Range 12m 12m 12m 12m
Outdoor Range 6m 6m 6m 6m
Power Supply 13.8Vdc 13.8Vdc 13.8Vdc 13.8Vdc
Consumption 30mA 40mA 50mA 60mA
Dimensions (WxD mm) 23 x 22.5 23 x 22.5 23 x 22.5 23 x 22.5
Height 0.5m 1.0m 1.5m 2.0m
Tamper Output Anti-removal & anti-opening
Alarm Logic Automatic Beam Interruption
Synchronisation Automatic Optical Synchronism
Colour Aluminium
Certification EN50131 Grade 3
Other Function Anti-Insect
Features
Active Infrared Barrier
Interior and exterior use
Self alignment system
Quick and easy to install
Small Modern and unobtrusive design
Slim line Robust aluminium housing
2 - 8 infrared beam versions
Sunlight filter
IP55 rated
EN50131 Grade 2 environment Class
Product Codes
616.017.100 Darwin Active Infra-red Barrier for
indoor and outdoor Use (2 beam, 0.5m)
616.017.101 Darwin Active Infra-red Barrier for indoor
and outdoor Use (4 beam,1m)
616.017.102 Darwin Active Infra-red Barrier for indoor
and outdoor Use (6 beam,1.5m)
616.017.103 Darwin Active Infra-red Barrier for indoor
and outdoor Use (8 beam, 2m)
616.017.104 GPS Darwin Beam Brackets (1x Pair).
Each pack contains a pair of brackets for
one side of the Beam unit only. You will
need 2 pairs of brackets , for 1 set of
Beams
Intruder Catalogue Chapter 6 Page 4 03/12
GPRS Darwin Active Infra Red Barriers
Intruder_Ch6_Detectorsbeam:Layout 1 20/03/2012 10:13 Page 4
Intruder Catalogue Chapter 7 Page 1
Chapter 7 - Detectors Glassbreak
03/12
Aritech Glass Break Detector
The Aritech GS 110 Glassbreak Detector has been designed
using the latest electronic techniques. This enables the
detector to contain all the necessary circuitry for excellent
detection whilst filtering out and rejecting all unwanted
signals that would normally result in a nuisance alarm(s),
e.g. ultra-sound, radio frequency interference, etc.
The Model GS 110 will operate from 10-15 vdc, providing a
2m radius of protection. Suitable for use on standard
window glass or plate glass, the GS 110 sensors detect a
frequency of150 Khz which appears when the glass is
broken.
Technical Specification
Power: 10 -15 Vdc
Standby 10 mA nominal at 12 V,
Alarm 26 mA nominal at 12 V
Alarm output: SPST relay NC 100 mA/28 Vdc
(Fail safe)
Coverage pattern: 2 metre radius
Environmental limits: -40C to + 70C
Dimensions: 28 x 28 x 12 mm
Weight: 28 g
Colour: white
Cable length: 3.0 m
EN5013: Grade 2
Features
Unobtrusive design
2m radius protection
Easy to install
Relay alarm contact
10-15 Vdc operation
Low current
Latching alarm L.E.D.
Fail safe
No adjustment
Tamper proof
Temperature limit 40C to + 70C
Waterproof
Product Codes
5443 Aritech GS110 Piezo break glass detector
2m (radius) range
8182 Adhesive kit for Piezo break glass detector
Coverage Pattern
Glass Break Detectors
Glass break detectors are used to provide early application of an attack on glass surface. There are generally two types of
detector, on glass and off glass. Off- glass detectors operate when they hear the frequency on breaking glass.
The advantage of this type of unit is that it can be mounted discreetly to the wall or ceiling near the window. On glass detectors
are fixed (usually with glue) to the actual surface of the window.
Intruder_Ch7_DetecGlassBrk:Layout 1 20/03/2012 10:14 Page 1
Chapter 7 - Detectors Glassbreak
Intruder Catalogue Chapter 7 Page 2 03/12
Aritech Shatterproof Detector
The Aritech 5815NT-ART Series ShatterPro3is the latest
breakthrough in Aritechs advanced series of acoustic
glassbreak sensors. In lab tests, ShatterPro3 provides 250
percent better false alarm immunity than the popular
ShatterPro.
II (GS 903N)
The coverage pattern can be easily adjusted to fit small or
large rooms. Interference outside the range will not cause
false alarms. The ShatterPro3 detects in a full 360
coverage pattern, with a maximum 7.6 m radius from sensor
to glass.
Using Aritechs patented Pattern Recognition Technology,
the sensor listens for actual patterns of breaking glass while
eliminating most false alarm patterns. ShatterPro3 listens
across the glassbreak frequency spectrum for greater false
alarm immunity.
Available with a round or rectangular housing, ShatterPro3
can be tested without opening the sensor by activating the
Aritech hand-held glassbreak tester at close range. A simple
hand-clap feature lets end-users confirm at any time that the
ShatterPro3 is operational.
Technical Specification
Input voltage: 9 to 16 Vdc
Current: Typical 15 mA
Maximum 25 mA
Detection range: 0.9 - 7.6 m x 360
Operating temperature: 0 to 50C
Recommended
glass thickness: Plate 2.4 - 6.4 mm
Tempered 3.2 - 6.4 mm
Wired 6.4 mm
Laminated 3.2 - 6.4 mm
Dimensions: 115H x 70W x 20D mm
EN50131: Grade 2
Features
250 percent better false alarm immunity
Adjustable to room size
All-new, easy-access design
Designed for quiet occupied areas on the perimeter loop
Consistent detection, even of soft, quiet glass-breaks
Detects through blinds and light drapes
End-user can test sensor operation with a clap of the
hands
Alarm memory
Product Code
616.008.011 5812EZ-W Sentrol ShatterPro3
Rectangular Detector
Intruder_Ch7_DetecGlassBrk:Layout 1 20/03/2012 10:14 Page 2
Chapter 7 - Detectors Glassbreak
Intruder Catalogue Chapter 7 Page 3 03/12
Features
Honeywell FG-1608T Glassbreak Detector and Magnetic Contact
The FG-1608T Series Break Glass Detectors apply Digital
Signal Processing using an on board Micro-controller to
instantly digitise sounds into mathematic sequences,
distinguishing common false alarms from breaking glass.
The digitised signal is compared against eight conditions:
Flush level threshold, audio level threshold, time
coincidence, flex/audio ratio, attack threshold, flex
duration, audio duration and microphone overload. If
these eight conditions match a glassbreak, the detector
alarms.
Technical Specification
Features
Superior False Alarm Immunity
Glassbreak Plus Forced Entry Detection
Easy Installation
Fast, Easy and Accurate Testing
Easily Verify Detector Operation at Any Time
Field Proven Glassbreak Protection
Product Code
5446 Glassbreak Detector and Magnetic
Contact
Dimensions: Glassbreak Detector: 114mm x
30mm x 23mm (h x w x d)
Magnetic Contact:
114mm x 13mm x 23mm
(h x w x d)
Weight: 85g
Range: 2.4m Maximum
Mounting Locations: Mount on doors, interior window
frames, corners, walls or ceilings
Alarm Relay: Form A(NC) / 250mA @25 Vdc
Alarm Duration: 5 Seconds (unaffected by alarm
LED latching)
Tamper Switch: Combination cover and wall
tamper, 25 mA @ 24 VDC
Power Requirements: 8 - 14 VDC, 17 mA typical @ 12
VDC 30 mA max. AC ripple: 4
volts peak to peak at Nominal
12VDC
Operating Temperature:
0C - 49C
ESD Immunity: 10 kV; discharges of either polarity
toexposed surfaces
RF Immunity: 30 V/m, 10 MHz - 1000 MHz
Suitable for use with EN50131-1
Approvals: UL Listed, PD6662 Security Grade
2 Environmental Grade II
Type Min. Thickness Max. Thickness
Plate 2.4mm 6.4mm
Tempered 3.2mm 6.4mm
Laminated* 3.2mm 14.3mm
Wired 6.4mm 6.4mm
Coated** 3.2mm 6.4mm
Sealed
Insulating * 3.2mm 6.4mm
The sound of breaking glass is
digitally simulated by the FG-701 and
is compatible for testing all Intellisense
glassbreak detectors. Testing
glassbreak detectors upon installation
is highly recommended.
Product Code
9094 FG-701 Glassbreak
Simulator
FlexGuard Glassbreak
Simulator/Tester
Intruder_Ch7_DetecGlassBrk:Layout 1 20/03/2012 10:14 Page 3
Chapter 7 - Detectors Glassbreak
Intruder Catalogue Chapter 7 Page 4 03/12
Honeywell FG-1625TAS Glassbreak Detector
The new FG-1625TAS Glassbreak Detector uses the latest
technology to provide faster response and increased false
alarm immunity. The FG-26TAS is designed to allow fast and
easy installation. Optimum operation can be quickly
verified using the FG-701 Glassbreak Simulator.
FlexCore Signal Processor
The FlexCore Signal Processor is an Application-Specific
Integrated Circuit (ASIC), which processes sound data in
parallel rather than sequentially; for faster, more accurate
detection decisions.
The combination of proven FlexGuard
is ideal for
use on new systems or for retro fits upgrading to
PD 6662 / EN 50131-1 Grade 3 & TS 50131-2-4.
The TMD 15
Imagine one product for all grades G2, G3, G4 and Fire
With GradeShift
DualCom
DigiSolo
and DigiPlus
is connected to
DualComs Gemini managed network free of charge but is
not enabled with the features of DigiPlus
until activated.
The DigiSolo
/DigiPlus
and DigiPlus