CURTIS LIGHTING, INC.

CURTIS "Low Brightness" SKYLUX


"Low Brightness" SkyLux for t\vo40-\vatt
lamps per section, Catalog No. 980-C.
Recommended for both store and office
lighting. Primarily for ceiling mount-
ing as individual four-foot units or in
continuous runs. Hangers are available
for pendant mounting.
"Low Brightness" SkyLux is character-
ized by high utilization and low lumi-
Electrical Testing Laboratories,
inc
3159*3 o.o~> 1OT12-L
CJUiDLEFOrfER DI3TRIBUTICB
CAT. N0.V80-C T10-40-4ttTT SOSPENSICW-ICUNTED FUBBE3OTT LOICNAIRE*
Tested In accordance with Specifications for Fluorescent UoAnalres -
ffp9
- Dlr*et
Rfiadored to CutUb Lighting. Inc.
- Two - 40 tettni 118 Volts; 2100 Uawnn; T-12 Shite Fluorescent.
Unit - Aleak aluninua reflectore end sides, reflection factor 0.82; opacified aln. 0.75.
suspension mounted.
Test - Cvutleponer distribution In U
planes Intersecting in the center of the
unit; A- a normal, B-3 parallel and C-C 4
5'
to the tubes.
Light output In per cent of bare l&apa
-0- 60" - 51.5
0- 50 - 58.5
V0-180 - 4.5
o
-lS0
#
- 63
X
RfS^
CANDLEFOTOR
Plan. FUot Plan.
And*.
155
US' 5.5
135' 75 6
US' 92 7.5 54.5
US' 76 8.5 60.5
10S' 51.5 8.5 39.5
95*
43 4.5 29
w 37.5 2.5 24.5
85' 43 25.0 29.5
75' 59 149 57
65' 110 299 153
55' 250 465 375
45' 540 620 695
35' 865 760 890
25' 1040 870 920
15 1020 950 985
5' 1010 9*5 995
0'
1000 1000 1000
Report Approved by
Two-oeuuoii "Luw >nguuiss" Xwiu OKyijUX unit
naire brightness. It is pleasingly
lumi-
nous when lighted, the Alzak
Aluminum
reflecting surfaces having a soft silvery
appearance.
The side reflectors shield the lamps in
the zone from 60
to 90.
There are no
horizontal reflecting or diffusing
surfaces
to collect dust.
Maintenance
costs are
low.
Material and Finish:
Made
of Alzak
Aluminum
and
steel, with Satin Aluminum
finish.
Dimensions:
Overall height,
6|"; width, 11|"; length,
48x"
Extra sections add
48
A".
Illumination Data: The
Coefficients of Utilization
Chart given below is derived
from the E.T.L. photometric
curve shown at left.
m 52772
tnginr , Pbotoaolrlc DepirtMiv In Chtrg* of Tast.
Plotted by: 9/* CoBmUd byi fi/? Ch.ck.d by: rwe April 2. 194$.
M-32
COEFFICIENTS OF UTILIZATION
REfLEC
TION
FACTOR
CEILING '5% 50% 30%
WALLS 505! 30% 10% 50% 30% 10% 30% I0J5
O
O
E
.6
E
D
C
-B
-
~A
13 K 28 .31 u 2i .30 2'
iS 3! :t .38 It .35 36 34
J
2 40 Pll 4t 39 .39 38
IE M 43 M .43 -: .42 41
a 46 45 46 IS 43 45 43
51 19 .47 19 M 46 - 45
.54 SI .50 52 50 49 45 48
.55 53 .51 53 .51 .50 .50 49
56 SI 55 51 Si .51 51 SO
57 s 54 55 54 .52 52
|
51
_fo
L
.-.re . tendttlw* MM.IMMM fact., .f 75*. g..l.<4.