"Low Brightness" SkyLux for t\vo40-\vatt lamps per section, Catalog No. 980-C. Recommended for both store and office lighting. Primarily for ceiling mount- ing as individual four-foot units or in continuous runs. Hangers are available for pendant mounting. "Low Brightness" SkyLux is character- ized by high utilization and low lumi- Electrical Testing Laboratories, inc 3159*3 o.o~> 1OT12-L CJUiDLEFOrfER DI3TRIBUTICB CAT. N0.V80-C T10-40-4ttTT SOSPENSICW-ICUNTED FUBBE3OTT LOICNAIRE* Tested In accordance with Specifications for Fluorescent UoAnalres - ffp9 - Dlr*et Rfiadored to CutUb Lighting. Inc. - Two - 40 tettni 118 Volts; 2100 Uawnn; T-12 Shite Fluorescent. Unit - Aleak aluninua reflectore end sides, reflection factor 0.82; opacified aln. 0.75. suspension mounted. Test - Cvutleponer distribution In U planes Intersecting in the center of the unit; A- a normal, B-3 parallel and C-C 4 5' to the tubes. Light output In per cent of bare l&apa -0- 60" - 51.5 0- 50 - 58.5 V0-180 - 4.5 o -lS0 # - 63 X RfS^ CANDLEFOTOR Plan. FUot Plan. And*. 155 US' 5.5 135' 75 6 US' 92 7.5 54.5 US' 76 8.5 60.5 10S' 51.5 8.5 39.5 95* 43 4.5 29 w 37.5 2.5 24.5 85' 43 25.0 29.5 75' 59 149 57 65' 110 299 153 55' 250 465 375 45' 540 620 695 35' 865 760 890 25' 1040 870 920 15 1020 950 985 5' 1010 9*5 995 0' 1000 1000 1000 Report Approved by Two-oeuuoii "Luw >nguuiss" Xwiu OKyijUX unit naire brightness. It is pleasingly lumi- nous when lighted, the Alzak Aluminum reflecting surfaces having a soft silvery appearance. The side reflectors shield the lamps in the zone from 60 to 90. There are no horizontal reflecting or diffusing surfaces to collect dust. Maintenance costs are low. Material and Finish: Made of Alzak Aluminum and steel, with Satin Aluminum finish. Dimensions: Overall height, 6|"; width, 11|"; length, 48x" Extra sections add 48 A". Illumination Data: The Coefficients of Utilization Chart given below is derived from the E.T.L. photometric curve shown at left. m 52772 tnginr , Pbotoaolrlc DepirtMiv In Chtrg* of Tast. Plotted by: 9/* CoBmUd byi fi/? Ch.ck.d by: rwe April 2. 194$. M-32 COEFFICIENTS OF UTILIZATION REfLEC TION FACTOR CEILING '5% 50% 30% WALLS 505! 30% 10% 50% 30% 10% 30% I0J5 O O E .6 E D C -B - ~A 13 K 28 .31 u 2i .30 2' iS 3! :t .38 It .35 36 34 J 2 40 Pll 4t 39 .39 38 IE M 43 M .43 -: .42 41 a 46 45 46 IS 43 45 43 51 19 .47 19 M 46 - 45 .54 SI .50 52 50 49 45 48 .55 53 .51 53 .51 .50 .50 49 56 SI 55 51 Si .51 51 SO 57 s 54 55 54 .52 52 | 51 _fo L .-.re . tendttlw* MM.IMMM fact., .f 75*. g..l.<4.