Anda di halaman 1dari 4

Nokia Corporation

1(4)

NOKI
Nokia Cellular Transmission
FlexiHopper C5.2.1 (and C3.3.1)
Release Note






RELEASE NOTE
23.3.2004 RN_FlexiHopper_C5.2.1.doc 2(4)
Product item codes for FlexiHopper C5.2.1 release:

Product Family/Equipment:

Structure Item, Name and
Code
Current
revision
New code New revision
FlexiHopper Outdoor Unit SW
P55046.01
E1 E2
Product item codes for FlexiHopper C3.3.1 release:

Product Family/Equipment:

Structure Item, Name and
Code
Current
revision
New code New revision
FlexiHopper Outdoor Unit SW
P55040.01
H0 H2

New features in FlexiHopper C5.2.1 (and C3.3.1):

Release Description:


- Performance 24h RX min/max monitoring
The following measurements are supported:
o 15m and 24h Rx level min/max monitoring with 1 record history
o 15m and 24h Rx level min/max monitoring with 16 record history
o The above measurements are supported by BSC S10.5 CD4.1 and OSS3.1 ED2 CD210 or later
- HSB support for SW activation of active OU
o When an active transmitter receives SW activation command in HSB configuration, it forces the operation
to the another transmitter before reset. The enhancement shortens bit error burst in case of SW
download/activation, when HSB configuration is used.







Customer Documents:


Structure item name Media format Item code
FlexiHopper User Manual PDF set on CD-ROM C33513.09J0
FlexiHopper User Manual PDF set in NOLS C33513.85J0






RELEASE NOTE
23.3.2004 RN_FlexiHopper_C5.2.1.doc 3(4)

Compatibility of FlexiHopper C5.2.1 (and C3.3.1)

Network element dependencies

FlexiHopper C5.2.1 (and C3.3.1) is compatible with following indoor units:
FIU19 C2.4 (SW P55230.01A8, HW A) in single mode (with Hopper Manager C4.5.2 or later).
FIU19 C4.3.1 (SW P55234.01C1, HW B and C) in single and HSB mode (with Hopper Manager C4.5.2) or later.
FIU19 C4.6 (SW P55234.01F0, HW C) in diversity modes (with Hopper Manager C4.5.2) or later.
FIU19E C1.5 (with Hopper Manager C4.5.2) or later.
FIU19E C2.0 (with Hopper Manager C4.6) or later
RRIC C2.2-2 and RRIC C3.3-2 (with Hopper Manager C4.5.2 or later)
FXC RRI ITN2.0 or later
AXC IFUE C2.0 (with AXC-FB Manager C1.2) or later

FlexiHopper C5.2.1 (and C3.3.1) is air-interface compatible with:
FlexiHopper Plus C1.0 or later (in 4-state modulation mode)

FlexiHopper C5.2.1 (and C3.3.1) has network level compatibility with:
TR 6.0 or later
RAN 1.5.2 ED2

Performance records for RX level measurements supported in BSC S10.5 12.16-0 (CD4.1) or later and NetAct OSS3.1 ED2
CD210 or later. NetAct Reporter support for NetAct DB viewing as per a separate change note (not supported currently).





RELEASE NOTE
23.3.2004 RN_FlexiHopper_C5.2.1.doc 4(4)

Known limitations

AXC-FB HopperManager C1.2 has following bugs with FlexiHopper C5.2.1 (and C3.3.1):



RRIC C3.3-2 has following bugs with FlexiHopper C5.2.1 (and C3.3.1):

Known bugs Effect Explanation Causes
traffic lost
Corrected in
release
1Commissioning bug with
Commissioning Wizard in
HSB mode
Minor+ When a radio capacity change with HopperManager
Commissioning Wizard is done to an existing HSB
configuration, the connection to the radio attached to the
FlexBus 2 is lost.

No No correction
planned. See
Technical Note
70.
2Configuration back-up in
HSB mode
Minor It is not possible to restore OU2's settings from IU (RRIC),
when 1IU+2OU HSB protection is in use.

No No correction
planned. See
Technical Note
70.

FXC RRI ITN2.1 (with RRI card manager C3.1-1) has following bug with FlexiHopper C5.2.1 (and C3.3.1):

Known bugs Effect Explanation Causes
traffic lost
Corrected in
release
1Fading margin
measurement (FMM) is not
supported
Minor+ Fading margin measurement results handling in RRI
manager is unreliable. In HSB mode use shown results are
in every second time wrong, and in single mode use
results are not shown at all for radio in FlexBus2
connection.

No Correction
planned with
ITN2.2.
2PM data is only collected
every other day from
radios that are connected
to FXC RRI units
Major FXC RRI does not report TRE measurement results
properly: The radio interface statistics are available only
every other day. Applies to TRE_24 Measurement.
TRE_SEL measurement works without errors.

This problem is valid with all the radios (FH C3.3.1, FH
C5.2.1, FHP C1.0, MH C3.1). The problem concerns only
the G.826 statistic values, the RX Min/Max results are got
without problems.

No Correction
planned with
ITN2.2.

Known bugs Effect Explanation Causes
traffic lost
Corrected in
release
1 Node manager hung major- Stop active task" in SWDL hangs the AXC-FB Manager, if
executed in first 5 seconds. Concerns only software down
load command.
No AXC FB-
manager C1.3
(SW release)




FIU19 A HW (T55240.01--A) has following bug with FlexiHopper C5.2.1 (and C3.3.1):

Known bugs Effect Explanation Causes
traffic lost
Corrected in
release
1Old FIU19 A HW
connected to two OUs in
single mode (FH+ or FH)
and OU automatic setting
back-up is on, FIU19 SW
might reset.
Minor The problem occurs, if all the connected radios have
the automatic setting backup feature "ON".
There should not be used automatic OU backup with
FIU19 A HW, but the setting backup can be stored
manually.
Not primarily No correction
planned.






Appendices: