Anda di halaman 1dari 2

PE NE T RON ADMI X

C R Y S T A L L I N E W A T E R P R O O F I N G A D M I X T U R E
T O T A L C O N C R E T E P R O T E C T I O N

Reservoirs
Sewage and Water Treatment Plants
Secondary Containment Structures
Tunnels and Subway Systems
Underground Vaults
Foundations
Parking Structures
Swimming Pools
Pre-Cast, Cast-in-Place and Shotcrete
applications
R O D U C T
A T A
H E E T
P
D
S
distributed evenly throughout the mix water. Add the
balance of materials to the ready-mix truck in accordance
with standard batching practices.
Ready Mix Plant - Central Mix Operation: Mix
PENETRON ADMIX

with water to form a very thin slurry


(e.g. 40 lbs (18 kg) of powder mixed with 6 gallons (22.7 l)
of water). Pour the required amount of material into the
drum of the ready-mix truck. The aggregate, cement, sand
and water should be batched and mixed in the plant in
accordance with standard practices (taking into account the
quantity of water that has already been placed in the
ready-mix truck). Pour the concrete into the truck and mix
for at least 5 minutes to ensure even distribution of
PENETRON ADMIX

throughout the concrete.


Precast Batch Plant: Add PENETRON ADMIX

to the
rock and sand, then mix thoroughly for 2-3 minutes before
adding the cement and water. The total concrete mass
should be blended using standard practices.
NOTE: It is important to obtain a homogeneous mixture
of PENETRON ADMIX

with the concrete. Therefore, do


not add dry PENETRON ADMIX

powder directly to wet


concrete as this may cause clumping and thorough disper-
sion will not occur. For further information regarding the
proper use of PENETRON ADMIX

for a specic project,


consult with a PENETRON Technical Representative.
Setting Time and Strength: The setting time of
concrete is affected by the chemical and physical composi-
tion of ingredients, temperature of the concrete and climat-
ic conditions. Retardation of set may occur when using
PENETRON ADMIX

. The amount of retardation will


depend upon the concrete mix design and the dosage rate
of PENETRON ADMIX

. However, under normal condi-


tions, PENETRON ADMIX

will provide a normal set


concrete. Concrete containing PENETRON ADMIX

may
develop higher ultimate strengths than plain concrete. Trial
mixes should be carried out under project conditions to
determine setting time and strength of the concrete.
Concrete treated with PENETRON ADMIX

should be
placed and nished in accordance with good concrete prac-
tices. ACI guidelines and recommendations should be
observed.
SPECIAL CONSIDERATIONS
When incorporating PENETRON ADMIX

, the tempera-
ture of the concrete mix should be above 40F (4C).
PACKAGING
PENETRON ADMIX

is available in 40 lb (18 kg) bags, 55


lb (25 kg) pails, and 6.6 lb (3 kg) soluble bags. For large
projects, customized packaging is available.
STORAGE / SHELF LIFE
PENETRON products must be stored dry at a minimum
temperature of 45F (7C). Shelf life is one year when stored
under proper conditions.
TECHNICAL SERVICES
For more detailed instructions, alternative application
methods, or information concerning the compatibility of the
PENETRON treatment with other products or technolo-
gies, contact the PENETRON Technical Department or
your local PENETRON representative.
SAFE HANDLING INFORMATION
PENETRON ADMIX

is alkaline. As a cementitious powder


or mixture, PENETRON ADMIX

may cause signicant skin


and eye irritation. PENETRON International, Ltd. also main-
tains comprehensive and up-to-date Material Safety Data
Sheets on all its products. Each sheet contains health and
safety information for the protection of your employees and
customers. Contact PENETRON International, Ltd. or your
local PENETRON representative to obtain copies of Mate-
rial Safety Data Sheets prior to product storage or use.
DESCRIPTION
PENETRON ADMIX

(integral crystalline waterproong admix) is added to the concrete mix at the time of batch-
ing. PENETRON ADMIX

consists of Portland cement, very ne treated silica sand and various active, proprietary
chemicals. These active chemicals react with the moisture in fresh concrete with the by-products of cement hydra-
tion to cause a catalytic reaction, which generates a non-soluble crystalline formation throughout the pores and
capillary tracts of the concrete. Thus the concrete becomes permanently sealed against the penetration of water or
liquids from any direction. The concrete is also protected from deterioration due to harsh environmental conditions.
PENETRON ADMIX

has been specially formulated to meet varying project and temperature conditions (see
SETTING TIME AND STRENGTH). Consult with a PENETRON Technical Representative for additional detailed
support on your project.
RECOMMENDED FOR
ADVANTAGES
Resists extreme hydrostatic pressure from either positive or negative surface of the concrete slab
Becomes an integral part of the concrete
Highly resistant to aggressive chemicals
Can seal hairline cracks up to 1/64 (0.4 mm)
Allows concrete to breathe
Non-toxic (NSF 61 certied for potable water applications)
Less expensive than traditional methods
Permanent
Added to the concrete at time of batching and therefore is not subject to climatic restraints
Reduces construction scheduling time
Improves durability of concrete
Permeability Reducing Admixture for Hydrostatic conditions (PRAH)
Zero VOC PENETRON powdered products contain zero volatile organic compounds and are safe for
use both outdoors and in confined indoor spaces.
DIRECTIONS FOR USE
Dosage Rate: 0.8-1.0% by weight of cement. Consult with PENETRONs Technical Department for assistance in
verifying the appropriate dosage rate and for further information regarding enhanced chemical resistance and
optimum concrete performance for your project.
Mixing: PENETRON ADMIX

must be added to the concrete at the time of batching.


The sequence of procedures for addition will vary according to the type of batch plant operation and
equipment. The following are some typical mixing guidelines. For more detailed information on dosing
procedures contact your PENETRON representative.
Ready Mix Plant - Dry Batch Operation: Add PENETRON ADMIX

in powder form to the drum of the


ready-mix truck. Drive the truck under the batch plant and add 60% - 70% of the required water along with
300-500 lbs (136-227 kg) of aggregate. Mix the materials for 2-3 minutes to ensure the PENETRON ADMIX

is
v. E05

T
O
T
A
L

C
O
N
C
R
E
T
E

P
R
O
T
E
C
T
I
O
N
distributed evenly throughout the mix water. Add the
balance of materials to the ready-mix truck in accordance
with standard batching practices.
Ready Mix Plant - Central Mix Operation: Mix
PENETRON ADMIX

with water to form a very thin slurry


(e.g. 40 lbs (18 kg) of powder mixed with 6 gallons (22.7 l)
of water). Pour the required amount of material into the
drum of the ready-mix truck. The aggregate, cement, sand
and water should be batched and mixed in the plant in
accordance with standard practices (taking into account the
quantity of water that has already been placed in the
ready-mix truck). Pour the concrete into the truck and mix
for at least 5 minutes to ensure even distribution of
PENETRON ADMIX

throughout the concrete.


Precast Batch Plant: Add PENETRON ADMIX

to the
rock and sand, then mix thoroughly for 2-3 minutes before
adding the cement and water. The total concrete mass
should be blended using standard practices.
NOTE: It is important to obtain a homogeneous mixture
of PENETRON ADMIX

with the concrete. Therefore, do


not add dry PENETRON ADMIX

powder directly to wet


concrete as this may cause clumping and thorough disper-
sion will not occur. For further information regarding the
proper use of PENETRON ADMIX

for a specic project,


consult with a PENETRON Technical Representative.
Setting Time and Strength: The setting time of
concrete is affected by the chemical and physical composi-
tion of ingredients, temperature of the concrete and climat-
ic conditions. Retardation of set may occur when using
PENETRON ADMIX

. The amount of retardation will


depend upon the concrete mix design and the dosage rate
of PENETRON ADMIX

. However, under normal condi-


tions, PENETRON ADMIX

will provide a normal set


concrete. Concrete containing PENETRON ADMIX

may
develop higher ultimate strengths than plain concrete. Trial
mixes should be carried out under project conditions to
determine setting time and strength of the concrete.
Concrete treated with PENETRON ADMIX

should be
placed and nished in accordance with good concrete prac-
tices. ACI guidelines and recommendations should be
observed.
SPECIAL CONSIDERATIONS
When incorporating PENETRON ADMIX

, the tempera-
ture of the concrete mix should be above 40F (4C).
PACKAGING
PENETRON ADMIX

is available in 40 lb (18 kg) bags, 55


lb (25 kg) pails, and 6.6 lb (3 kg) soluble bags. For large
projects, customized packaging is available.
STORAGE / SHELF LIFE
PENETRON products must be stored dry at a minimum
temperature of 45F (7C). Shelf life is one year when stored
under proper conditions.
TECHNICAL SERVICES
For more detailed instructions, alternative application
methods, or information concerning the compatibility of the
PENETRON treatment with other products or technolo-
gies, contact the PENETRON Technical Department or
your local PENETRON representative.
SAFE HANDLING INFORMATION
PENETRON ADMIX

is alkaline. As a cementitious powder


or mixture, PENETRON ADMIX

may cause signicant skin


and eye irritation. PENETRON International, Ltd. also main-
tains comprehensive and up-to-date Material Safety Data
Sheets on all its products. Each sheet contains health and
safety information for the protection of your employees and
customers. Contact PENETRON International, Ltd. or your
local PENETRON representative to obtain copies of Mate-
rial Safety Data Sheets prior to product storage or use.
DESCRIPTION
PENETRON ADMIX

(integral crystalline waterproong admix) is added to the concrete mix at the time of batch-
ing. PENETRON ADMIX

consists of Portland cement, very ne treated silica sand and various active, proprietary
chemicals. These active chemicals react with the moisture in fresh concrete with the by-products of cement hydra-
tion to cause a catalytic reaction, which generates a non-soluble crystalline formation throughout the pores and
capillary tracts of the concrete. Thus the concrete becomes permanently sealed against the penetration of water or
liquids from any direction. The concrete is also protected from deterioration due to harsh environmental conditions.
PENETRON ADMIX

has been specially formulated to meet varying project and temperature conditions (see
SETTING TIME AND STRENGTH). Consult with a PENETRON Technical Representative for additional detailed
support on your project.
RECOMMENDED FOR
ADVANTAGES
Resists extreme hydrostatic pressure from either positive or negative surface of the concrete slab
Becomes an integral part of the concrete
Highly resistant to aggressive chemicals
Can seal hairline cracks up to 1/64 (0.4 mm)
Allows concrete to breathe
Non-toxic (NSF 61 certied for potable water applications)
Less expensive than traditional methods
Permanent
Added to the concrete at time of batching and therefore is not subject to climatic restraints
Reduces construction scheduling time
Improves durability of concrete
Permeability Reducing Admixture for Hydrostatic conditions (PRAH)
Zero VOC PENETRON powdered products contain zero volatile organic compounds and are safe for
use both outdoors and in confined indoor spaces.
DIRECTIONS FOR USE
Dosage Rate: 0.8-1.0% by weight of cement. Consult with PENETRONs Technical Department for assistance in
verifying the appropriate dosage rate and for further information regarding enhanced chemical resistance and
optimum concrete performance for your project.
Mixing: PENETRON ADMIX

must be added to the concrete at the time of batching.


The sequence of procedures for addition will vary according to the type of batch plant operation and
equipment. The following are some typical mixing guidelines. For more detailed information on dosing
procedures contact your PENETRON representative.
Ready Mix Plant - Dry Batch Operation: Add PENETRON ADMIX

in powder form to the drum of the


ready-mix truck. Drive the truck under the batch plant and add 60% - 70% of the required water along with
300-500 lbs (136-227 kg) of aggregate. Mix the materials for 2-3 minutes to ensure the PENETRON ADMIX

is
C R Y S T A L L I N E W A T E R P R O O F I N G A D M I X T U R E
T O T A L C O N C R E T E P R O T E C T I O N

PE NE T RON ADMI X

Penetron International, Ltd.


45 Research Way, Suite 203
East Setauket, NY 11733, USA
+1 (631) 941-9700
penetron.com
info@penetron.com
004aCPR2013-07-10
EN 934-2
Penetron International Ltd.
601 South Tenth Street,
Unit 300
Allentown, PA 18103
08
PENETRON ADMIX
Crystalline Capillary
Admixture
Water Resisting Admixture
Chloride content:
< 0,10 % by mass
Alkali content:
< 10,3 % by mass
Compressive strength:
85 % of control
Conventional dry material
content: > 99,5 %
Air content in fresh concrete:
2 % by volume
Capillary Absorption (after 90
day curing): 60 % by mass
R O D U C T A T A H E E T
P D S
WARRANTY
PENETRON INTERNATIONAL, LTD. warrants that the products manufactured by it shall be free from material defects
and will conform to formulation standards and contain all components in their proper proportion. Should any of the
products be proven defective, the liability to PENETRON INTERNATIONAL, LTD. shall be limited to replacement of the
material proven to be defective and shall in no case be liable otherwise or for incidental or consequential damages.
PENETRON INTERNATIONAL, LTD. MAKES NO WARRANTY AS TO MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE AND THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EXPRESSED OR IMPLIED. User shall determine
the suitability of the product for its intended use and assume all risks and liability in connection therewith.

Anda mungkin juga menyukai