Anda di halaman 1dari 4

1

Dynamic energy
storage systems
VSS
+
DC
Voltage Support Solution
To ensure an autonomous static power supply
from 60 to 500 kVA
> Service sectors
> Industry
> Telecommunications
> Medical applications
Your protection
for
V
S
S

0
0
1

B
Reliable power is essential to keep critical functions operational.
Energy storage is of highest importance to UPS availability:
the VSS
+
DC dynamic storage solution removes restrictions linked to traditional battery use,
the VSS
+
DC system provides a high level of availability for DELPHYS MP or DELPHYS MX Uninterruptible Power Supply units,
the solution inverter DELPHYS with dynamic storage of energy VSS
+
DC was carried out by the partnership between SOCOMEC SICON UPS
and PENTADYNE.
Many advantages
Outstanding reliability (5 year warranty)
Reduced maintenance
Long service life (> 20 years)
Max. power in min. volume
Less floor space < 0.5 m
2
High efficiency 99.8%
Micro-processor controlled
Self-diagnostics
Control system with LCD display
Rapid recharging (20 seconds)
Adjustable of voltage and current parameters
Silent
Cabinet on castors for ease of installation
No load restrictions on ground
Installation requiring no structural work
Cable access via upper section
Simplified connections
Units coupled in parallel to increase power
and back up-time
Access front maintenance
Environmentally-friendly
2
Dynamic energy
storage systems
VSS
+
DC
Voltage Support Solution
The various configurations
Various solutions or combinations far meeting your requirements for electrical energy availability
are possible depending on your operating constraints and technical environment.
Operation during power outages
The VSS
+
DC system is connected to the DC
bus ; it supplies the inverter when the low-
voltage system exceeds the voltage tolerances.
Thereby providing 99.5% protection against
system failures.
Working with a generator unit
The VSS
+
DC supplies the inverter long enough
for an emergency generator unit to take over
the power supply.
Working with a battery
When connected in parallel with a battery, the
VSS
+
DC cuts in during short power failures ;
battery backup is maintained and its capacity
is used for major cuts. Battery life is extended
by infrequent demands (life cycle).
Working in parallel
Several VSS
+
DC units connected in parallel
increase power and available backup time.
GS
Operating principle
VSS
+
DC is a dynamic energy storage system
Using a very high-speed, rotating flywheel
Combined flywheel, shaft and generator
The rotating assembly is held up by electro
magnetic, with no contact with other parts
A maintenance-free internal system vacuum
annihilates friction
The flywheel-driven generator supplies
energy to the UPS during a power failure,
thus providing continuous power to the load
When mains power is restored, the flywheel
takes as well as 20 seconds to return to Full
speed.
V
S
S

0
0
4

A
V
S
S

0
0
5

A

G
B
V
S
S

0
0
6

A
V
S
S

0
0
7

A
1
4
5
6
7
2
3
1. Housing
2. Carbon-glassfibre flywheel
3. Stator windings
4. Upper magnetic bearing
5. Vacuum system
6. Rotor
7. Lower magnetic bearing
V
S
S

0
0
9

A
3
Dynamic energy
storage systems
VSS
+
DC
Voltage Support Solution
VSS
+
DC advantages
Dynamic energy storage technology with yet
more technical advantages:
simplified maintenance:
- no wearing parts,
- no vacuum pump requiring maintenance
or replacement,
high efficiency,
silent operation,
simple operation.
The VSS
+
DC works without the constraints of batteries
VSS
+
DC systems provide end-users with
excellent results for very low operating costs.
The VSS
+
systems may be used in operating
conditions where battery use is impossible;
the system is unaffected by ambient
temperatures.
VSS
+
DC Battery
Operating costs
Energy consumption very high efficiency energy consumption to maintain Float charge
Maintenance reduced high
Ventilation - Air conditioning not applicable maintaining ambient temperature increases operating costs
Technical floor space reduced considerable, with ground loading constraints
Service life high (> 20 years) frequent replacements
Autonomy availability
Reliability high need for constant monitoring
Knowledge of availability continuous actual backup time difficult to ascertain
Life cycle (number of discharges) no impact on service life reduces service life
Ambient temperature no impact reduced temperature range
Recharge time very low reduced (100% in about 20 seconds) important (80% in about 8 hours)
G
A
M
M
E

0
5
1

B
Autonomy versus power output
Specification
0
0
100
200
300
400
500
600
700
800
900
1000
5 10 15 20 25 30 35 40
AUTONOMY (s)
1 unit
2 units
3
u
n
its
4
u
n
its
5
u
n
it
s
POWER (kW)
1
8
0
0
8
3
0
6
3
0
Standard equipment
Control panel with LCD display
Dry contact interface
Additional equipment
Emergency stop (button on door)
Air filter
Communication options
Remote management
Dimensions
ELECTRICAL
Nominal unit power up to: 190 kW/12.5 seconds - 220 kW/5 seconds
Voltage (input/output) 600 V DC
Output voltage control 1% under static conditions
Ripple factor < 2%
Auxiliary voltage 110/230 V AC
Auxiliary power 400 VA
ENVIRONMENT
Noise level (ISO3746) < 45 dB
Operating temperature - 20 C to + 50 C
Operating altitude up to 3000 metres
Conformity with standards CEE 73/23 Low voltage directive
CEE 98/037 Machine directive
CEI /EC 60439-1
CEI /EN 60204-1 Machine safety
EN1127-1 Explosive atmospheres
V
S
S

0
0
3

A

G
B
V
S
S

0
0
2

A
Weight: 590 kg
This document is not a specification.
SOCOMEC SICON UPS reserves the right to make any changes to data without prior notice.
ISO 9001: 2000
FM 28237
VALID FOR FRANCE VALID FOR ITALY
H E A D O F F I C E
SOCOMEC GROUP SWITCHING PROTECTION AND UPS
S.A. SOCOMEC capital 10 956 600 - R.C.S. Strasbourg B 548 500 149
B.P. 10 - 1, rue de Westhouse - F-67235 Benfeld Cedex
SOCOMEC SICON UPS Strasbourg
11, route de Strasbourg - B.P. 50 - F-67235 Huttenheim Cedex- FRANCE
Tel. +33 (0)3 88 57 45 45 - Fax +33 (0)3 88 74 07 90
ups.benfeld.admin@socomec.com
SOCOMEC SICON UPS Vicenza
Via della Tecnica, 1 - I - 36030 Villaverla - ITALY
Tel. +39 0445 359 111 - Fax +39 0445 359 222
info.it.ups@socomec.com
S A L E S A N D MA R K E T I N G
M A N A G E M E N T
SOCOMEC SICON UPS PARIS
95, rue Pierre Grange
F-94132 Fontenay-sous-Bois Cedex - FRANCE
Tel. +33 (0)1 45 14 63 90
Fax +33 (0)1 48 77 31 12
ups.paris.dcm@socomec.com
R

f
.

D
O
C

6
5
0
1
3

-

0
5
/
0
6

-

P
h
o
t
o

:

M
a
r
t
in

B
e
r
n
h
a
r
t

&

P
e
n
t
a
d
y
n
e

-

R

a
lis
a
t
io
n

:

S
O
C
O
M
E
C

S
e
r
v
ic
e

C
o
m
m
u
n
ic
a
t
io
n

-

G
y
s
s

I
m
p
r
im
e
u
r

O
b
e
r
n
a
i
www.socomec-sicon.com
Dynamic energy
storage systems
VSS
+
DC
Voltage Support Solution

Anda mungkin juga menyukai