Anda di halaman 1dari 67

A

t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
PerkinElmer, the undisputed leader in Atomic
Absorption (AA), is the preferred choice for atomic
spectroscopy solutions and services in thousands
of laboratories globally, helping you advance
research and development, control product
quality and improve the environment.
With a product line that features flame AA,
high-performance graphite furnace, standard-
setting WinLab32 software and a wide array
of consumables and accessories, PerkinElmer
AAs are designed to meet your most demanding
requirements for productivity, flexibility,
ruggedness and performance.
Standards
Atomic Absorption
THGA Graphite Tubes and Supplies
Lumina Hollow Cathode Lamps
QUICK-FIND INDEX Page #
Autosampler Sample Cups 11
Autosampler Sample Probes 9
Burner Heads and Components 13
Electrodeless Discharge Lamps 46
Filters, Regulators, and
Supplies 36
Flow Injection Sampling
Supplies 21
HGA Graphite Tubes and
Contact Cylinders 31
Lumina Hollow Cathode Lamps 39
Matrix Modifiers 67
MHS System and Supplies 49
Sample Preparation Supplies 50
Nebulizers 16
Standards 65
THGA Graphite Tubes and
Contact Cylinders 34
WinLab32 Software for AA 70
HGA Graphite Tubes and Supplies
PerkinElmer offers a wide selection of superior quality products designed to work with
your PerkinElmer instruments. Our precision-designed products deliver the peace of
mind that comes from knowing that youll get the results you need.
The Quick Find Index to the left will help you find products fast. For your convenience,
products are alphabetized by category, sub-category, and family. There is also a more
complete Alphabetical INDEX on page 429 and a Part Number INDEX on page 407.
PerkinElmer tubes are manufactured to the highest quality
specifications. To ensure high quality and consistency, a
specific grade of high-density base graphite material has
been developed for PerkinElmers exclusive use. This base
graphite material is used for the manufacturing of all
PerkinElmer graphite tubes.
Page 31
Every genuine PerkinElmer Lumina lamp is designed
for use with, and tested on, our spectrometers to
assure compatibility and the highest performance.
PerkinElmer offers a wide range of single-element and
multi-element HCLs, which are ideal for determining most
elements by atomic absorption spectroscopy.
Page 39
PerkinElmer offers a wide selection of atomic absorption
calibration standards. Each solution is supplied with a
comprehensive Certificate of Analysis that documents
the quality. To ensure that your measurements are
accurate, you can rely on our certificates to provide
complete information.
Page 65
Our exclusive design ensures even heating over the entire
length of the tube. PerkinElmers unique, transversely
heated graphite tube includes an integrated platform. The
exceptionally uniform temperature distribution obtained
with transverse heating significantly reduces or eliminates
condensation of the sample matrix components and
memory effects, and improves the atomization
efficiency for refractory elements.
Page 34
AAnalyst 200
The AAnalyst

200 dramatically changes


the way instruments are used and serviced,
while maintaining all of the performance
users have come to expect from PerkinElmer.
The system incorporates innovations
typically only offered on expensive research-
grade instrumentation. True double-beam
Echelle optics combined with the power of
a solid state detector delivers performance
levels not typically available with flame
AA. Plus, fully automated gas controls
and integrated safety checks yield the
safest flame AA system available today.
Features:

Intuitive touch screen is easy-to-use


no training required

Snap-in, snap-out parts are easily


replaced, so there is no downtime

Rugged design can handle the toughest matrices

PerkinElmer reliability and performance


at an affordable price

Features the first true double-beam


Echelle optical system
AAnalyst 400
The AAnalyst 400 system is designed for
the rigorous needs of todays analytical
laboratory, with proven WinLab32
software providing all the flexibility
and power you need in an easy-to-use,
easy-to-learn package.
AAnalyst 600
The AAnalyst 600, a dedicated
transversely heated graphite atomizer
(THGA) system, offers the best in
graphite furnace. With Zeeman
background correction, the AAnalyst
600 exceeds the requirements of todays
laboratories, whether analyzing difficult
samples or for achieving the lowest
detection levels. The high-light-
throughput optical system combined
with a solid-state detector, provides
the highest quality efficiency and
signal-to-noise performance of any
AA system on the market.
AAnalyst 700
The AAnalyst 700 Atomic Absorption
Spectrometer offers productivity
enhancing features for flame and furnace
atomic absorption in a proven cost-
effective design. The fully integrated
benchtop system includes flame and
heated graphite furnace atomizers
(HGA) with continuum source
background correction.
AAnalyst 800
For laboratories that need the best in both
flame and THGA furnace, the AAnalyst
800 provides a fully integrated benchtop
system with superior performance. With
the AAnalyst 800, switching between
flame and furnace is as simple as a click
of the mouse and includes automatic
alignment for optimum performance.
The high-light-throughput optical system
combined with a solid-state detector,
provides the highest quality efficiency
and signal-to-noise performance of any
AA system on the market.
OVER 40 YEARS OF EXPERTISE
With over 40 years experience and a product line that
includes flame AA systems, high-performance graphite
furnace AA systems, flexible ICP-OES systems, and the
most powerful ICP-MS systems, PerkinElmer is the
undisputed leader in inorganic analysis. We have
placed over 40,000 systems throughout the world,
performing inorganic analyses every hour of every day.
PerkinElmer is a world leader in chemical analysis. Our
analytical instrument technologies serve the rapidly
evolving pharmaceutical, chemical, environmental,
forensics, and semiconductor industries, providing
integrated solutions from sample handling and
analysis to communication of test results.
The World Leader in
Atomic Absorption
7
AAnalyst 200
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
A
u
t
o
s
a
m
p
l
e
r

S
u
p
p
l
i
e
s

a
n
d

A
c
c
e
s
s
o
r
i
e
s
Autosampler Supplies and Accessories
Autosampler Flame/FIAS Trays and Vessels
8
Description Part No. Each
AS-91 Plexiglass Cover B3000111 1103
AS-93plus Dust Cover B3140770 1001
Plexiglass cover for reduced contamination
of samples from ambient particulates
Adapter Plate for Gilson Racks for AS-93plus B3140647 48
Required in order to use Gilson racks on an AS-93
AS-93plus Rinsing Kit
Includes: Part No. Each
Adapter M B0507919 15
Connector B3140715 2
Pump Tube - 1.14 mm i.d., (pkg. 6) B3140730 57
Pump Tube - 2.79 mm i.d., (pkg. 6) B3140721 60
PVC Rinse Liquid Feed Tube - 2 m B0048139 1
Tygon

Drain Tube - 2 m B0509650 16


Rinsing Port B3140622 36
AS-90plus Rinsing Kit
Includes the rinse vessel (B300-0156) and the appropriate
adapter and tubing. The vessel may not
fit trays manufactured prior to 1996.
AS-90/90A/90plus
Capacity Sample Vessel Size Part No. Each
Tray A-144 4.5 mL, 6 mL, 8 mL B3000133 338
Tray B-98* 15 mL, 16 mL B3000132 113
Tray C-36 50 mL B3000135 338
Blank Tray B0501056 421
AS-91
Capacity Sample Vessel Size Part No. Each
Tray E-218 4.5 mL, 6 mL, 8 mL B0509554 440
Tray F-152 15 mL, 16 mL B0509555 440
Tray G-55 50 mL B0508520 440
AS-93plus
Capacity Sample Vessel Size Part No. Each
9/29 50 mL/15 mL B3001647 26
30 50 mL B3140621 26
60 15 mL, 16 mL B3140618 26
90 4.5 mL, 6 mL, 8 mL B3140617 26
AS-90/90A/
90plus/91/93plus
Translucent polypropylene
vessels with excellent
chemical resistance.
Sample Vessel Volume Quantity Part No. Each
4.5 mL 1000 N9301204 75
6 mL** 500 B0193235 325
8 mL 1000 B0508901 453
15 mL** 500 B0193233 325
16 mL 1000 N9301205 93
50 mL** 500 B0193234 257
Caps, for 8 mL Vessels
Package of 1000.
AS-90/91 Wash Vessel, Polypropylene
Includes cover (250 mL).
AS-50/51
Description Part No. Each
Polystyrene Test Tubes 00471441 32
Cone-shaped bottoms permit use of small
samples. Clear, affordable polystyrene is
recommended for use with most aqueous
solutions (125 test tubes)
Berzelius Tall-form Beaker 00471440 6
Pyrex

beaker (400 mL) used as a wash


vessel for the autosampler
Sample Trays
Sample Vessels
Rinsing Kits
Tubes and Beakers
*Polypropylene sample tray.
** Includes screw caps.
Trays A, C, E, F, and G are powder-coated, corrosion-resistant aluminum.
AS-93plus sample trays are polypropylene.
Part No. Each
B0508902 153
Part No. Each
B0501258 36
Accessories
AS-93plus
Part No. Each
B3140236 292
Part No. Each
B3000166 185
()
()
()
()
()
()
()
()
()
()
()
A
u
t
o
s
a
m
p
l
e
r

S
u
p
p
l
i
e
s

a
n
d

A
c
c
e
s
s
o
r
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
9
Autosamplers automate standard and sample introduction
for instrument calibration and sample analysis via software
commands, extending the spectrometers capabilities to
those of a fully-automated analytical workstation.
Stainless Steel
Description Part No. Each
Sampling Probe Assembly, B3000159 198
0.6 mm i.d.
Stainless steel sampling probe and screw fitting, B3000152,
and flame capillary tubing assembly, B3000157.
Sampling Probe Assembly, B3000160 198
0.6 mm i.d.
Stainless steel sampling probe and screw fitting, B3000152
and FIAS
TM
capillary tubing assembly B3000158.
Standard Sampling Probe Assembly, B3000161 198
1.0 mm i.d.
Stainless steel sampling probe and screw fitting, probe B3000152,
and FIAS capillary tubing assembly B0191060.
Corrosion-Resistant
Description Part No. Each
Flame Sampling Probe Assembly, B3001770 217
0.6 mm i.d.*
Corrosion-resistant probe, suitable for inorganic acids and most organic
solvents, except NMP. Includes sampling probe with FEP tube and screw
fitting (B3000055) and capillary tubing assembly (B3000157).
Sampling Probe Assembly, B3001771 198
0.6 mm i.d.*
Corrosion-resistant probe, suitable for inorganic acids and most organic
solvents, except NMP. Includes sampling probe with FEP tube and screw
fitting (B3000055) and capillary tubing assembly (B3000158).
Standard Sampling Probe Assembly, B3001772 217
1.0 mm i.d.*
Corrosion-resistant probe, suitable for inorganic acids and most organic
solvents, except NMP. Includes sampling probe with FEP tube and screw
fitting (B3001769), and capillary tubing assembly (B0191060).
Corrosion-Resistant Sampling Probes
with Screw Fitting
Suitable for inorganic acids and most organic solvents,
except NMP. Requires, but does not include, one of the
capillary tubing assemblies described below.
Description ID Part No. Each
Corrosion-Resistant Sampling Probe 0.6 mm B3000055 134
Corrosion-Resistant Sampling Probe 1.0 mm B3001769 97
Stainless Steel Sampling Probe w/Screw Fitting
Requires, but does not include,
one of the capillary tubing
assemblies described below.
Capillary Tubing Assembly
Depending on the autosampler application, the sampling
probe can be equipped with any of three types of capillary
tubing assembly, which have different tubing diameters and
either one or two screw fittings.
Description Part No. Each
1 m length, 0.6 mm i.d., one fitting B3000157 40
1 m length, 0.6 mm i.d., two fittings B3000158 18
1 m length, 1.0 mm i.d., two fittings B0191060 19
Used Oil Autosampler Probe
Autosampler probe for the AS-90plus and the AS-93plus
Autosamplers. The probe includes a
particulate filter on the tip to remove
fibers. For use in used oil analysis.
Stainless Steel Sampling Probe
For use with both aqueous
and organic samples. (pkg. 5)
Platinum/Rhodium Sampling Probe**
Accessory probe recommended for use
when samples corrosive to stainless
steel are being analyzed. (pkg. 1)
Quartz Sampling Probes***
Probe recommended for use when
samples corrosive to stainless steel
are being analyzed. (pkg. 5)
Sampling Probe Cleaning Wire (1 M)
For AS-90/91/90plus/93plus probe.
Sampling Probe Assemblies,
AS-90/90A/90plus/91/93plus
Sampling Probes, AS-50/51
Part No. Each
B0505962 42
Part No. Each
B3000152 143
** Not recommended for use with samples containing aqua regia.
*** Cannot be used with samples containing hydrofluoric acid or other
reagents corrosive to quartz.
* Probe cannot be used with AS-90s, which have the older sampling probe holder.
Sampling Probe Assembly Components,
AS-90/90A/90plus/91/93plus
Part No. Each
N0771529 249
Part No. Each
00471422 18
Part No. Each
00471420 363
Part No. Each
N0580540 112
Autosampler Supplies and Accessories
Autosampler Flame/FIAS Probes
Stainless Steel Probe
Part No. B3000152
Sampling Probe Supplies
()
()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
A
u
t
o
s
a
m
p
l
e
r

S
u
p
p
l
i
e
s

a
n
d

A
c
c
e
s
s
o
r
i
e
s
Autosampler Supplies and Accessories
Dilution System Supplies
10
4 4
5
3
2
1
1
AutoPrep 50 Tubing
The AutoPrep
TM
50 provides automatic, intelligent on-line
dilution capabilities for flame Atomic Absorption.
Key features of the AutoPrep 50 include:
Fully automatic sample introduction
Automatic intelligent selection of dilution range
Automatic preparation of multiple standards from
a single stock solution
Integrated software control
Diluter Parts
Description Part No. Each
Pump Assembly, 5 mL B3141052 103
(includes pump head and piston assembly)
Sample Holding Coil, 5 mL B3140123 117
Valve 1 (V1, 3-port with red mark) B3002072 40
Valve 2 (V2, 3-port with yellow mark) B3002094 40
Valve 3 (V3, 3-port with black mark) B3002076 41
Valve 4 (V4, 3-port with black mark) B3002091 40
T-union (T1, black mark) B3002097 45
Thumbscrew for Valves and T-union B3140211 26
Thumbscrew for Sample Holding Coil B3140210 26
Sampling Probe for AS 90/91, complete, B3140244 124
connects AS 90/91 to AutoPrep 50 Valve 3
Nuts and Ferrules
Description Part No. Each
Front Ferrule for 2.4 mm o.d. tubing (B0017998) B3001333 11
Back Ferrule for 2.4 mm o.d. tubing (B0017998) B3001334 10
Nut for 2.4 mm o.d. tubing (B0017998) B3001335 7
Front Ferrule for 1.6 mm o.d. tubing (B0029792) 09920123 19
Back Ferrule for 1.6 mm o.d. tubing (B0029792) 09920124 16
Nut for 1.6 mm o.d. tubing (B0029792) B0080333 7
Tubing
Description Part No. Each
Diluent and Waste Tube B3140226 40
(connects to V1 or V4), complete,
1.7 mm i.d., 2.4 mm o.d., 1.2 m long
Diluent Feed Tube (connects to V2), B3140227 34
complete 1.0 mm i.d.,
1.6 mm o.d., 0.7 m long
PTFE Tubing B0509652 3
(connects the T-union with the
nebulizer) 0.56 mm i.d., 1.67 mm o.d.
PTFE Tubing, used to interconnect B0029792 2
valves, 1.0 mm i.d., 1.6 mm o.d.
PTFE Tubing, used to connect the
sample pump to the valve (V1), B0017998 3
1.7 mm i.d., 2.4 mm o.d.
Tubing Cutter B3000019 43
5
4
3
2
1
AutoPrep 50
AutoPrep 50
()
()
()
A
u
t
o
s
a
m
p
l
e
r

S
u
p
p
l
i
e
s

a
n
d

A
c
c
e
s
s
o
r
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Autosampler Supplies and Accessories
Graphite Furnace Autosampler Supplies for the AS-40/60/70/71/72/800
11
Heavy-duty construction prevents cracking or tipping
Conical design allows for use of entire sample
Your choice of materials:
Polystyrene Clear, recommended for use with most
aqueous solutions.
Polyethylene Translucent, low density, recommended
for use with most aqueous and organic solutions.
Teflon

Recommended for use with most concentrated


acids including HF and for analyses where the lowest
detection levels are required.
Polypropylene Translucent. No known solvent at
room temperature.
Graphite Furnace Autosampler Cups
Volume Composition Qty. Part No. Each
7 mL**** Polypropylene 100 B3001567 33
3.5 mL** Polystyrene 100 B0129303 34
2.5 mL** Polypropylene 1000 B3001566 47
2 mL* Polyethylene 1000 B0087056 53
2 mL* Polystyrene 1000 B0119079 82
2 mL* Teflon 30 B0087600 242
1.2 mL*** Polypropylene 2000 B0510397 61
Pliers
For 1.2 mL sample cups.
Description Part No. Each
For Model AS-40
Sample Tray B0101045 459
For Models AS-60/70
Sample Tray* B0510417 66
For Models AS-71/72
40-Position Tray, Plastic B0510417 66
35 sample locations for 2 or 3.5 mL sample cups*
80-Position Tray, Plastic B0510404 41
75 sample locations for 1.1 mL sample cups*
Sample Tray Cover B3001330 23
For Model AS-800
88-Position Tray, Polypropylene B3001507 21
80 sample locations for 2, 2.5, or 3.5 mL sample
cups. Each sample tray also has eight positions
for 7 mL reagent containers.
148-Position Tray, Polypropylene B3001506 21
132 sample locations for 1.1 mL sample cups
and eight locations for 2.5 or 3.5 mL sample
cups. Each sample tray also has eight positions
for 7 mL reagent containers.
AS-800 Supplies
Arm B3002046 8
Sampling Arm Collar B3001465 14
Set Screw for Collar B0055900 1
Sample Tray Cover B3001505 17
* Each sample tray has five positions for 30 mL
cloverleaf-shaped reagent containers
Description Part No. Each
Inlet (complete) B3002007 267
Includes ferrules and connector
Outlet (complete) B3002006 267
Includes ferrules and connector
Solvent-Resistant Check Valves
Description Part No. Each
Inlet B0105973 437
Outlet B0105974 359
Autosampler Sample Cups
Part No. Each
B0510398 11
* For use with AS-40/60/70/71/72/800 *** For use with AS-71/72/800
** For use with AS-60/70/71/72/800 **** For use with AS-800
Autosampler Trays
Check Valves
148-Position Tray, Polypropylene
(For Model AS-800)
Part No. B3001506
88-Position Tray, Polypropylene
(For Model AS-800)
Part No. B3001507
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
A
u
t
o
s
a
m
p
l
e
r

S
u
p
p
l
i
e
s

a
n
d

A
c
c
e
s
s
o
r
i
e
s
Autosampler Supplies and Accessories
Graphite Furnace Autosampler Supplies for the AS-40/60/70/71/72/800
12
Rinse Tubing Ferrules
Description Size Part No. Each
Front Ferrule 2.45 mm i.d. B3001333 11
Rear Ferrule 2.45 mm i.d. B3001334 10
Sample Tubing Ferrule Kit (1.6 mm i.d.)
Used with B0129258 and
B0101161 sampling capillaries.
Contains 5 front and 5 rear ferrules.
Tubing Only (PTFE)*
Description Size Part No. Each
Rinse Tubing 1.6 mm o.d. B0029792 2
Sample Tubing 2.45 mm o.d. B0017998 3
For Models AS-40/60/70/71/72
Round Reagent Containers
For blank solutions, reagent solutions, or matrix modifiers.
Volume Composition Part No. Each
20 mL PTFE* B0103037 40
20 mL Polypropylene** B0101164 10
25 mL Polystyrene*** B0102332 5
For Models AS-60/70/71/72
Cloverleaf-Shaped
Reagent Containers
30 mL polypropylene.
Resists most acid solutions
Provides more reagent volume, yet
occupies only one sample space
Allows you to insert up to five
different reagent solutions
or matrix modifiers for one run
Rinse Solution Bottle (2 L)
Waste Solution Bottle (2 L)
Solvent- and acid-resistant sampling components
PTFE pipette tips and capillaries for reduced contamination
Easy replacement
Description Part No. Each
For Model AS-40
Sampling Capillary B0101161 242
For Models AS-60/70/71/72/800
Sampling Capillary B0129258 242
Ferrule Kits
Part No. Each
B0132799 34
Part No. Each
B0104281 110
Part No. Each
B0104987 41
* Solvent-resistant (AS-40 only)
** Suitable for organic solutions
*** Not suitable for organic solutions
Sampling Capillaries
AS-800 Autosampler
Reagent Containers
Part No. Each
B0086142 68
* Order per meter.
Sampling Capillary
(For Models AS-60/70/71/72/800)
Part No. B0129258
()
()
()
()
()
()
()
()
B
u
r
n
e
r

S
y
s
t
e
m

C
o
m
p
o
n
e
n
t
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Burner System Components
AAnalyst 100/200/300/400/700/800
13
AAnalyst Burner Heads cannot be used with other PerkinElmer
AA Spectrometers.
Single-Slot Nitrous Oxide-Acetylene
The 5 cm nitrous oxide burner head is required
for nitrous oxide-acetylene operation. This
burner head can also be
used with air-acetylene
or rotated to provide
reduced sensitivity.
Single-Slot Air-Acetylene
The 10 cm burner head is designed to be used
with the air-acetylene flame. Because of its
long burner path length, it provides the best
sensitivity for air-
acetylene elements.
Three-Slot Air-Acetylene
The three-slot burner head (10 cm) is designed
to be used when analyzing samples with high
concentrations of dissolved solids. The three-
slot burner head is not
compatible with some
older gas control systems.
Single-Slot Air-Acetylene
A 5 cm air-acetylene burner head (5 cm) is
available for applications in which reduced
sensitivity is required. It can be rotated to
provide further sensitivity
reduction, and it has a wide
slot to prevent clogging.
Burner Head Cleaning Tool
Burner Heads
Components Part No. Each
Viton Burner Head O-Ring 09902219 2
Burner Mixing Chamber Assembly 00570948 402
Clamping Ring N0401171 26
Flow Spoiler 00572561 20
End Cap O-Ring
Aqueous (Viton) 09902147 2
Organics (Corkprene) 00472014 3
Aqueous and Organics (KALREZ

)* 09921044 266
End Cap Assembly N0370392 287
Used with the following nebulizers:
03030352, 03030404, 03030299.
End Cap Assembly 00570984 440
Used with the following nebulizers:
B0505480, B0505590, N0370394,
N0370393, N3150188.
Impact Bead and Retainer Assembly
This can only be used with the End Cap Assembly
(Part No. 00570984).
Description Part No. Each
Seal Plug 00572624 38
Large Impact Bead O-Ring 09902240 3
O-Ring (1/8 in.) 09902236 2
Impact Bead 00572615 70
Impact Retainer 00572695 30
Split Lockwasher 09911286 1
Binding Head Screw 09910148 1
Burner Gasket Kit 00470988 71
Includes: Kit Qty. Part No. Each
Corkprene End Cap O-Ring 5 00472014 3
Viton End Cap O-Ring 3 09902147 2
Viton Burner Head O-Ring 1 09902219 2
Small Impact Bead O-Ring 3 09902236 2
Large Impact Bead O-Ring 3 09902240 3
Magnet Assembly for AAnalyst N2010381 32
700/800
Magnet Assembly for AAnalyst N1010215 32
100/200/300/400
Components Part No. Each
Drain Tubing, AAnalyst 100/200/300/400/700/800 02507987 22
AAnalyst 700/800 Drain Assembly N2011074 1346
AAnalyst 100/300 Drain Assembly N0400058 779
Drain Bottle 09904991 112
Burner System Components
B
C
D
E
F
G1
G2
1
2
3
4
5
6
7
Part No. Each
N0400100 982
Part No. Each
N0400102 982
Part No. Each
N0400103 982
Part No. Each
N0400101 982
Part No. Each
03031573 3
* Recommended for use when determination of organic and acid based
solutions required
1
2
2
3
5
6
7
3
4
G1 G2
F
E
D
A
B
C
Drain Components
A
A
A
A
()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
B
u
r
n
e
r

S
y
s
t
e
m

C
o
m
p
o
n
e
n
t
s
14
Burner System Components
Models 2280, 2380, 3030(B), 3100, 3110, 3300, 4000*, 5000*, and 5100 PC
Single-slot Burner Head 00400266 893
The 10 cm burner head is designed to be used with the
air-acetylene flame. Because of its long burner path length,
it provides the best sensitivity for air-acetylene elements.
Nitrous Oxide Burner Head 00400277 867
The 5 cm nitrous oxide burner head is required for nitrous
oxide-acetylene operation. This burner head can also be used
with air-acetylene or rotated to provide reduced sensitivity.
Three-slot Burner Head 00400289 867
The three-slot burner head is designed to be used when
analyzing samples with high concentrations of dissolved solids.
The three-slot burner head is not compatible with
some older gas control systems.
Burner Head Cleaning Tool 03031573 3
Components Part No. Each
Viton Burner Head O-Ring 09902219 2
Aqueous Viton End Cap O-Ring 09902147 2
Organic (Corkprene) End Cap O-Ring 00472014 3
Aqueous/Organic (Kalrez) 09921044 266
End Cap O-Ring
Clamping Ring 00572616 78
Stainless Steel Locking Ring 00572737 107
Use N0371071 for Models 3300,
3110, and 3100
End Cap Assembly** 00570984 440
Flow Spoiler 00572561 20
Burner Mixing Chamber 00570948 402
Impact Bead Assembly
Impact Bead 00572615 70
Seal Plug 00572624 38
O-Ring (1/4 in./6 mm i.d.) 09902240 3
O-Ring (1/8 in./3 mm i.d.) 09902236 2
Impact Retainer 00572695 30
Split Lockwasher 09911286 1
Binding Head Screw 09910148 1
Burner Gasket Kit
Includes: Kit Qty. Part No. Each
Corkprene End Cap O-Ring 5 00472014 3
Viton End Cap O-Ring 3 09902147 2
Viton Burner Head O-Ring 1 09902219 2
Small Impact Bead O-Ring 3 09902236 2
Large Impact Bead O-Ring 3 09902240 3
Burner Drain Assembly 00470391 236
Includes Drain Loop and Interlock only, for Models 2280, 2380, 3030(B),
4000, 5000, and 5100 PC.
Burner Drain Assembly N0370149 252
Includes Drain Loop and interlock only, for Models 3100, 3110, and 3300.
Components Part No. Each
For Air-Acetylene Burner Head (short pin) 00400276 56
For Nitrous Oxide Burner Head (long pin) 00400275 56
Hold Down Cable 03030130 10
Burner Heads
Cable and Pin Assemblies
E3
E2
E1
Burner System Components
E1
E2
E3
1
2
3
4
A
5
B
C
D
6
7
8
9
10
11
* For use on models 4000 and 5000 shipped after May 1980
** A different end cap assembly, N0370392, is required for use
with the high-sensitivity nebulizer
E
5
C
1
4
B
2
3
A D
8
6
7
7
8
9
10
11
Part No. Each
00470988 71
()
()
()
()
B
u
r
n
e
r

S
y
s
t
e
m

C
o
m
p
o
n
e
n
t
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Burner System Components
Models 1100(B), 2100, and 4100
15
Single-Slot Burner Head B0162668 918
The 10 cm burner head is designed to be used with
the air-acetylene flame. Because of its long burner
path length, it provides the best sensitivity for
air-acetylene elements.
Nitrous Oxide Burner Head B0162669 1530
The 5 cm nitrous oxide burner head is required for
nitrous oxide-acetylene operation. This burner head
can also be used with air-acetylene or rotated to
provide reduced sensitivity.
Burner Head Cleaning Tool 03031573 3
Components Part No. Each
1 Viton Burner Head O-Ring 09902219 2
2 Aqueous End Cap O-Ring B0158690 11
3 Organic (Corkprene) End Cap O-Ring B0158598 7
4 Hold Down Wire (Pkg. 1, not shown) B0160697 47
5 Flow Spoiler 00572561 20
6 Burner Mixing Chamber B0153250 523
7 Impact Bead Assembly B0151579 580
8 Impact Bead, Ceramic B0158616 79
A End Cap and Drain Interlock Assembly B0151573 561
B Insert B0157117 38
C Clamping Ring B0162671 226
Aqueous Burner Gasket Kit Assembly B0155546 210
For Aqueous Solutions.
Includes: Kit Qty. Part No. Each
Viton Burner Head O-Ring 1 09902219 2
Aqueous End Cap O-Ring 1 B0158690 11
Corkprene End Cap O-Ring 5 B0158598 7
Plug O-Ring (Aqueous) 2 B0151697 1
O-Ring between End Cap and Drain Vessel 1 B0129926 1
Organic Burner Gasket Kit Assembly B0173404 848
For Organic Solutions. Includes Gaskets, O-Rings, and Seals for the
Models 4100, 2100, or 1100(B). Delivered in convenient storage box.
Includes: Kit Qty. Part No. Each
Plug O-Ring 3 B0174378 56
O-Ring and Drain 1 B0174379 50
End Cap Gasket 1 B0174380 45
O-Ring and Bead Holder Assembly 1 B0181842 57
O-Ring on Nebulizer Venturi 1 B0190001 45
O-Ring, High-Sensitivity Nebulizer 1 B0190672 29
Drain Tube (2 m) 1 B0102949 12
Burner Heads
E
E
J
E
I
9
C
B
10
11
H
F
G
Burner System Components
9
10
11
C
B
F
G
H
I
J
Burner Head Cleaning Tool
Part No. 03031573
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
B
u
r
n
e
r

S
y
s
t
e
m

C
o
m
p
o
n
e
n
t
s
Burner System Components
Nebulizers
16
PerkinElmer nebulizers are available in a variety of
configurations to meet all of your analytical needs.
The nebulizer is one of the most important components in
a flame AA spectrometer. Sample solutions, with differing
physical properties, must be converted into an aerosol of
small, similarly sized droplets. This places great demands
on the design of the nebulizer.
All PerkinElmer nebulizer assemblies are adjustable for
optimized performance and include easily interchanged
capillary assemblies for simple, reduced-cost maintenance.
PerkinElmer nebulizers are manufactured to exacting tolerances
to provide maximum sensitivity. Universal, or standard,
nebulizers are less expensive than the corresponding high-
sensitivity nebulizers and provide a lower level of sensitivity.
The universal, or standard, nebulizers typically provide
better precision and reduced carryover interference when
used with solutions that contain high dissolved solids and
content of higher analyte concentrations.
Corrosion-Resistant Nebulizer
For all solutions containing hydrofluoric acid or aqua regia
For all solutions containing high concentrations of
dissolved solids
All internal components in contact with solutions are
constructed of plastic to resist corrosion from
concentrated acids
Reduced performance compared with stainless steel or
platinum/rhodium nebulizers
GemTip

Nebulizer
Corrosion-resistant and can be used to aspirate almost
all solutions, even those solutions containing a high
percentage of acids
Designed to obtain optimum sensitivity, detection limits,
and precision with flame atomic absorption for both
air-acetylene and nitrous oxide-acetylene flames
High-Sensitivity Nebulizers
Provide maximum sensitivity, precision, and freedom
from analytical interferences
The high-sensitivity nebulizer with platinum/iridium
capillary is for most solutions, but not for precious metal
samples containing aqua regia
High-sensitivity nebulizer with tantalum capillary used
for solutions containing aqua regia
Platinum Alloy Nebulizer
Recommended for most concentrated acids
containing
>
5% acid
Includes a platinum alloy needle assembly and a
tantalum venturi
Provides maximum chemical resistance
Not suitable for use with aqua regia or hydrofluoric acid
Stainless Steel Nebulizer
For most solutions containing <5% acid, providing
exceptional performance and durability
Excellent performance
B
u
r
n
e
r

S
y
s
t
e
m

C
o
m
p
o
n
e
n
t
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Burner System Components
Nebulizer Assemblies and Components Quick Reference
17
Plastic Body Nebulizers
For AAnalyst 100/300/700/
For AAnalyst 800, Models 3100/3110/3300/
200/400 5000/5100 PC and Earlier AAs 1100(B)/2100/4100
Stainless Steel Body Nebulizers
A
B
A
B
A
B
D
F
E
A
D
F
C
E
GemTip Nebulizer (see page 18) Part No. Each Part No. Each Part No. Each
GemTip Nebulizer Assembly
3
N0370394 663
High-Sensitivity GemTip Nebulizer Assembly
3
N0370393 1167
High-Sensitivity Nebulizer with Pt/Ir Capillary
4
(see page 19) Part No. Each Part No. Each Part No. Each
Nebulizer Assembly
3
N3150188 423 B0505480 1518 B0501029 1518
Nebulizer End Cap Nut B0501026 7 B0501026 7
Nebulizer Spacer 09902015 6
Nebulizer Body B0506666 166 B0506668 166
Impact Bead B0505086 63 B0505086 63 B0505086 63
Locking Ring B0501025 7 B0501025 7
Capillary Assembly B0501022 242 B0501022 242
High-Sensitivity Nebulizer with Tantalum Capillary
4
(see page 19) Part No. Each Part No. Each Part No. Each
Nebulizer Assembly
3
B0505590 1734 B0505589 1734
Nebulizer End Cap Nut B0501026 7 B0501026 7
Nebulizer Body B0506666 166 B0506668 166
Capillary Assembly B0505588 599 B0505588 599
Impact Bead B0505086 63 B0505086 63
Locking Ring B0501025 7 B0501025 7
Corrosion-Resistant Nebulizer
1
Part No. Each Part No. Each Part No. Each
Nebulizer Assembly 03030404 752 N3110110 1167
Capillary Assembly 03030402 242 03030402 242
Capillary Assembly for AS-51 or AS-50 00570957 236 00570957 236
O-Ring Kit N9300065 84 N9300066 84
Venturi 03031920 134 03031920 134
Platinum Alloy Nebulizer
1
Part No. Each Part No. Each Part No. Each
Nebulizer Assembly 03030299 1059 N3110111 1518
Capillary Assembly
2
03030433 395 03030433 395
O-Ring Kit N9300065 84 N9300066 84
Venturi 03033124 536 N3111158 854
Stainless Steel Nebulizer
1
(see page 20) Part No. Each Part No. Each Part No. Each
Nebulizer Assembly 03030352 606 N3110109 1001
Capillary Assembly 03030354 134 03030354 134
O-Ring Kit N9300065 84 N9300066 84
Venturi 03031810 134 B0166503 111
1 - Stainless steel body 2 - Etched with a P for identification 3 - Requires End Cap Assembly (N0370392) 4 - Inert plastic body with red adjusting ring
C
A
() () ()
() () ()
() () ()
() () ()
() () ()
() () ()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
B
u
r
n
e
r

S
y
s
t
e
m

C
o
m
p
o
n
e
n
t
s
18
Burner System Components
Nebulizers and Components
For AAnalyst
TM
100/300/700/800*
Description Part No. Each
Universal GemTip Assembly Complete** N0370394 663
High-Sensitivity GemTip Assembly Complete** N0370393 1167
Component Part No. Each
Capillary Tubing 09908265 29
Adjustment Nut N0371492 25
Gland Nut N0371505 13
Teflon Tubing 09985708 7
Capillary Holding Assembly*** N0371520 223
Capillary Holding Assembly**** N0371522 223
O-Ring 09926083 10
Impact Bead***** B0505086 63
O-Ring 09902015 6
O-Ring****** B0174378 56
Body Assembly*** N0370398 402
Body Assembly**** N0370399 427
Locking Nut N0371493 12
Spring 09902473 1
Connector Nut N0371485 13
Magnet Holder Assembly N1010215 32
1
2
3
4
5
6
7
8
9
10
11
12
13
1
2
3
4
5
6
11
10
9 8
7
13
12
Nebulizer Capillary Tubing
10 ft. (3 m) length of 0.58 mm i.d.
polyethylene tubing, for use with
the stainless steel, platinum/
rhodium and GemTip
TM
Nebulizers.
Not suitable for corrosion-resistant
nebulizers where capillary tubing is
part of capillary
assembly. Not
compatible with N3150188 Nebulizer.
Nebulizer Cleaning Wires
Made of soft alloy copper,
these cleaning wires are
specially deburred to prevent
scratching of the orifices and
internal components of the
nebulizers while cleaning.
Use only PerkinElmer
cleaning wires to clean
nebulizers. (pkg. 5)
Nebulizer Grease
A small quantity of Apiezon

-L
grease helps to lubricate the
O-Ring seals for reassembly and
ensures leak-proof operation. A
tube of grease is supplied with
each complete nebulizer assembly.
However, you should order the tube if you purchase separate
capillary and venturi sections.
Accessories
Part No. Each
03030135 17
Part No. Each
03030405 9
Part No. Each
09908265 29
* Shipped before Fall 1999
** Requires End Cap Assembly (N0370392)
*** For Universal GemTip Nebulizers
**** For high-sensitivity GemTip Nebulizers
***** Included with high-sensitivity GemTip Nebulizer only
****** Organic Resistant
GemTip Nebulizer
GemTip Nebulizers
()
()
()
()
()
B
u
r
n
e
r

S
y
s
t
e
m

C
o
m
p
o
n
e
n
t
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Burner System Components
Nebulizers and Components
19
C
21
F
22
23 E
D
A
For Models AAnalyst 100/300/700/800/
1100(B)/2100/3100/3110/4100/5100 PC
Description Part No. Each
High-Sensitivity Nebulizer Assembly with
Pt/Ir Capillary B0505480 1518
High-Sensitivity Nebulizer Assembly with
Tantalum Capillary B0505590 1734
Components Part No. Each
O-Ring B0174378 56
Spring B0165332 3
O-Ring B0190672 29
/ / / / See chart on page 17
High-Sensitivity Nebulizers*
21
22
23
A C D E F
For Models AAnalyst 200/400/700*/800*
Description Part No. Each
High-Sensitivity Nebulizer Assembly with
Pt/Ir Capillary N3150188 423
Components Part No. Each
Impact Bead Structure B0505086 63
Nebulizer Spacer 09902015 6
High-Sensitivity Nebulizer
with Pt/Ir Capillary
C
1
C
1
High-Sensitivity Nebulizer with Pt/Ir Capillary
High-Sensitivity Nebulizer
* Requires End Cap Assembly (N0370392)
* Requires End Cap (N0370392)
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
Burner System Components
Nebulizers and Components
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
B
u
r
n
e
r

S
y
s
t
e
m

C
o
m
p
o
n
e
n
t
s
20
Stainless Steel Body
Nebulizers and Parts
For Models AAnalyst 100/300/700/800,* 5100 PC,
5000, 3300, 3110, 3100, and Earlier AAs**
Description Part No. Each
Stainless Steel Nebulizer Assembly 03030352 606
Description Part No. Each
O-Ring 09902005 1
Insert 03031812 68
Nebulizer Body 03030353 64
Front End Cap 03031808 14
O-Ring 09902239 1
Adjustment Nut 03031460 41
Locking Ring 03031456 9
Washer 03031802 4
O-Ring 09902102 1
Spring 03031806 5
/
See chart on page 17
* For AAnalyst spectrometers shipped starting Fall 1999
** May be used on AAnalyst 200/400. Requires End Cap (00570984)
For Models 4100, 2100, and 1100(B)
Description Part No. Each
Stainless Steel Nebulizer Assembly N3110109 1001
Description Part No. Each
O-Ring B0045095 1
Insert B0057336 31
Nebulizer Body B0152456 88
B0166507 159
Front End Cap B0166502 15
O-Ring B0148651 3
Adjustment Nut B0166505 32
B0057408 41
Locking Ring B0166506 13
B0057409 15
Washer B0057334 6
O-Ring B0057761 2
Spring B0057410 5
/
See chart on page 17 B A
20
19
18
17
16
15
14
13
12
11
B A
10
9
8
7
6
5
4
3
2
1
11
12
13
11
B
14
15
20
19
A
18
17
16
1
2
3
1
B
4
5
10
9
A
8
7
6
Stainless Steel Nebulizer
()
()
()
()
F
l
o
w

I
n
j
e
c
t
i
o
n

S
a
m
p
l
i
n
g

S
u
p
p
l
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Flow Injection Sampling Supplies
Flow Injection Analysis and Mercury Systems
21
PerkinElmer pioneered the use of flow injection techniques
with atomic spectroscopy. The use of flow injection with
AA, ICP, and ICP-MS saves time, costs and manpower,
while at the same time extending your analytical flexibility
and capabilities.
The overall benefits include:
Increased sample throughput
Reduced reagent consumption
Reduced sample volume
Automated cold vapor mercury determinations using U.S.
Environmental Protection Agency-approved methodology
Automated hydride generation determinations
Automated analyte preconcentration
Matrix removal
Automated sample dilution and reagent addition
Enhanced performance for samples
with high dissolved solids content
FIMS Tubing Diagram
The Flow Injection Mercury System (FIMS) is an extremely
small and easy-to-operate atomic absorption instrument
dedicated to trace mercury determination. Based on flow
injection techniques, it is fully automated, fast, and cost-
effective. FIMS provides exceptional sensitivity, precision,
and detection limits.
Flow Injection
Analysis Systems (FIAS
TM
)
Flow Injection
Mercury Systems (FIMS
TM
)
FIMS and Autosampler
FIAS 100
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
F
l
o
w

I
n
j
e
c
t
i
o
n

S
a
m
p
l
i
n
g

S
u
p
p
l
i
e
s
Flow Injection Sampling Supplies
FIAS and FIMS Parts and Supplies
22
Quartz Cell 2 for FI-MHS
For use with the electrically heated
cell assembly or an air-acetylene
flame with
suitable mount.
Quartz Window
Quartz Window Assembly
Part of Quartz Cell 2.
Universal Quartz Cell Holder
Allows mounting of the FIAS-100/400
Quartz Cell to Models 5100, 3030, 2380,
3300, 3110, 3100, and AAnalyst series.
Note: If both NaBH
4
and SnCl
2
are to be used as reducing agents with FIAS
systems configured for Hg/hydride determinations, it is strongly recommended
that separate mixing manifolds, gas-liquid separators, quartz cells, and
required tubing and connectors be dedicated for use with each
reducing agent.
See page 25 for a complete listing of fittings, tubing, and flow injection supplies.
Absorption Cell Body
Quartz Window Assembly
Kit Includes: Part No. Each
Window B0066549 21
Holder B3000243 12
FIMS Source Mercury Lamp
Mercury Lamp Extractor
For removing mercury lamp.
Silicone Sleeve
For FIMS Cell Sample Inlet.
Silicone Tubing
For FIMS Cell Exhaust Outlet, 3 m.
Hg Scrubber Kit
Traps mercury vapor from the FIMS system. Eliminates the
need for an expensive exhaust vent.
Recommended by the U.S. EPA.
Included with FIMS-100/400.
Hg Replacement Filter
Gas/Liquid Separator
Modular building block-type gas-liquid separator
made from chemically resistant plastic. An
exchangeable PTFE membrane in the screw cap
of the separator prevents liquid from being carried
into the quartz cell or ICP torch when working
with strongly foaming samples.
(For ICP-MS use B0193772.)
Mixing Manifold
Modular building block-type mixing manifold with one
mixing channel and three connections; two inlet, and one
outlet. Made from chemically resistant plastic. Several of these
blocks can be plugged together easily
to create a single unit with enhanced
mixing capabilities. Part of B0507957.
Mixing/Separation Assembly
Complete modular unit, consisting of two mixing manifolds
with tubing adapters K and M, a gas-liquid separator with a
PTFE membrane, five spare PTFE
membranes, one PTFE tube (110 mm
long), and one PTFE tube (300 mm long).
Chemifold
For use with Glass Gas/Liquid Separator.
Gas/Liquid Separator Holder
for Glass Separator
Glass Gas/Liquid Separator
PTFE Membrane
For use with the B0507959
Gas/Liquid Separator. (pkg. 50)
Plug Connector
For connection of the mixing manifold
and gas/liquid separator blocks.
FIAS Cells and Supplies
Part No. Each
B0507486 854
Part No. Each
B0066549 21
Part No. Each
B0507487 140
Part No. Each
B3000350 338
FIMS Cells and Supplies
Part No. Each
B0510487 214
Part No. Each
B0510370 84
Part No. Each
B3000243 12
Part No. Each
B0046948 3
Part No. Each
B3000277 134
Part No. Each
B3000274 107
Gas/Liquid Separator Consumables
Part No. Each
B0507959 147
Part No. Each
B0187258 402
Part No. Each
B0509479 377
Part No. Each
B0193772 204
Part No. Each
B0508306 319
Part No. Each
B0507962 50
Part No. Each
B0507957 504
Part No. Each
B0507960 13
Part No. Each
B0018283 11
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
()
Flow Injection Sampling Supplies
FIAS and FIMS Parts and Supplies
F
l
o
w

I
n
j
e
c
t
i
o
n

S
a
m
p
l
i
n
g

S
u
p
p
l
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
23
Magazine for Peristaltic Pump
One wide (>2 mm) tubing channel.
Magazine for Peristaltic Pump
Two narrow (<2 mm) tubing channels.
Pump Roller Assembly
Alternate Reductant Kit
Permits use of the FIAS-100, FIAS-400, and FIAS-400MS
with an alternate reductant
(e.g., SnCl
2
instead of NaBH
4
).
Includes:
Description Part No. Each
Mixing/Separation Assembly B0507957 504
700 mm Single Flanged PTFE Tubing B0191059 29
PTFE Tubing (110 mm) B0191058 19
Red/Red Pump Tubing (pkg. 12) B0193160 37
Adapter A B0193342 12
PTFE Tubing (300 mm) B0198097 19
FIAS Accessories Case
Includes the most frequently used FIAS supplies, including
adapters, pump tubings, connectors,
sample loops, and PTFE tubings.
Flangeless Ferrule
For 1/16 in. tubing, Blue Tefzel

.
Naflon

Single Tube Dryer


Continuously and highly selectively removes water from
gaseous samples without affecting analytes. (Requires
separate flow controller.)
FI Switching Valve*, 5-port
For on-line preconcentration.
Included with all
FIAS systems.
FI Switching Valve*, 8-port
For FIAS-MS.
Push-button Assembly
For manual program actuation
with the FIAS-100 and FIAS-400.
Included with the FIAS-100.
Disassembly Tool
Valve dismantling tool.
One-Way Valve
* For FI valve repair or replacement parts, please
contact your local PerkinElmer Service office.
Pump Magazines
Part No. Each
B0507792 217
Part No. Each
B0507791 217
Part No. Each
B3000251 125
Spare Parts
Part No. Each
B0508594 695
Part No. Each
B3000240 3310
Part No. Each
09903799 4
Part No. Each
N9306016 204
Switching Valves
Part No. Each
B0507914 714
Part No. Each
B0505650 120
Part No. Each
B0509095 1418
Part No. Each
B0509590 4
Part No. Each
B0198111 96
()
()
()
()
()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
F
l
o
w

I
n
j
e
c
t
i
o
n

S
a
m
p
l
i
n
g

S
u
p
p
l
i
e
s
Flow Injection Sampling Supplies
FIAS and FIMS Tubing Adapters and Connectors
24
Adapters with Internal Threads
Connectors
Type Description Part No. Each
K / L 1/4 in. (6.4 mm)
External Screw Thread,
K = 1.8 mm o.d. Nipple. B0507918 14
L = 2.8 mm o.d. Nipple. B0507920 16
M 1/4 in. (6.4 mm) B0507919 15
External Screw Thread,
4 mm o.d. Nipple.
N 1/4 in. (6.4 mm) External B0507949 40
Screw Thread, 0.7 mm o.d.
Pt/lr Capillary Nipple.
Screw Plug B0507921 9
1/4 in. (6.4 mm)
External Screw Thread.
Type Description Part No. Each
A / B 1/4 in. (6.4 mm)
Internal Screw Thread,
A = 1.8 mm o.d. Nipple. B0193342 12
B = 3.3 mm o.d. Nipple. B0506716 40
C 1/4 in. (6.4 mm) B0196850 38
Internal Screw Thread,
4 mm o.d. Nipple.
E 1/4 in. (6.4 mm) B0196857 38
Internal Screw Thread,
for the Quartz Cell.
F 1/4 in. (6.4 mm) Internal B0193873 57
Screw Thread, 0.7 mm o.d.
Pt/lr Capillary Nipple.
G 1/4 in. (6.4 mm) Internal B0501580 71
Screw Thread, Two Nipples
to connect tubes to the
Preconcentration Accessory.
Type Description Part No. Each
IA Connector with Nipples B0199233 4
for 1.7 to 3.2 mm
i.d. tubes.
IB Connector with Nipples B0196882 1
for 2.4 to 3.2 mm
i.d. tubes.
II Connector with 1/4 in. B0196704 3
(6.4 mm) Internal
Screw Thread.
IIIA T-piece with Nipples B0199035 14
for 1.5 to 2.5 mm
i.d. tubes.
IIIB T-piece with Nipples B0198201 17
for 3.5 to 4.5 mm
i.d. tubes.
Screw Connector Tightening Tool
For convenient tightening and loosening
of the screw connectors used with
PTFE tubing assemblies.
Part No. Each
B0501315 47
Adapters with External Threads
I
E
II
II
K
K
FIAS-400
()
()
()
()
F
l
o
w

I
n
j
e
c
t
i
o
n

S
a
m
p
l
i
n
g

S
u
p
p
l
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Flow Injection Sampling Supplies
FIAS and FIMS Tubing and Supplies
25
Peristaltic Pump Tubing
Peristaltic pump tubing has a wall thickness of 0.84 mm unless
noted otherwise. Part numbers are for a package of 12 pieces.
i.d. (mm) Color Code Part No. Each
0.76 Black/Black B0506058 37
1.14 Red/Red B0193160 37
1.52 Yellow/Blue B0193161 37
2.06 Violet/Violet B0199034 37
3.18 Black/White B0508310 37
Peristaltic Pump Tubing, Solvent-Resistant
White/white, 0.84 mm i.d.
Resistant to organic solvents. (pkg. 12)
PVC Waste Tubing
3 mm i.d. with 1 mm wall thickness,
no fittings. Price per meter.
Silicone Tubing
1 m x 5 mm i.d., no fittings.
The following are part numbers for PTFE tubing, O-Rings,
and screw connectors to prepare tubing assemblies.
PTFE Tubing Assemblies
Color
i.d (mm) (Screw Fittings) Length (mm) Part No. Each
1.0 Blue 700 B0191059 29
1.0 Blue 110 B0191058 19
1.0 Blue 300 B0198097 19
1.0 Blue 1000 B0191060 19
1.75 Black 250 B0198099 61
1.75 Black 450 B0198100 61
0.35 White 60 B0501594 34
Flanging Tool
Used with PTFE tubing, screw
connectors, and O-Rings to make
tubing assemblies.
Screw Connectors
Color Description Part No. Each
White For 0.35 mm i.d. PTFE Tubing B0502923 1
Red For 0.5 mm i.d. PTFE Tubing B0181354 1
Green For 0.7 mm i.d. PTFE Tubing B0502924 1
Blue For 1.0 mm i.d. PTFE Tubing B0502925 1
Black For 1.75 mm i.d. PTFE Tubing B0502921 1
Note: These connectors are all the same size.
The color code is a universal system to denote the tubing i.d.
O-Rings
Description Part No. Each
For 0.35 - 1.0 mm i.d. Tubing B0507708 1
For 1.75 mm i.d. Tubing B0045472 1
PTFE Tubing (sold by meter)
Tubing i.d. Part No. Each
0.35 mm B0506060 3
0.5 mm B0507020 3
0.7 mm B0507021 2
1.0 mm B0029792 2
1.75 mm B0017998 3
Description Part No. Each
200 L B0194048 36
500 L B0194049 36
1000 L B0501000 55
3-D Reaction Coil
3-dimensional reactor, 0.35 i.d.
(two flanged ends).
Peristaltic Pump Tubing
Part No. Each
B0048139 1
Part No. Each
B0018283 11
Part No. Each
B0507692 62
PTFE Tubing, Screw
Connectors, and O-Rings
Part No. Each
B3000001 198
Sample Loops
Part No. Each
B0501595 64
PTFE Tubing
Part No. B0198097
()
()
()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
F
l
o
w

I
n
j
e
c
t
i
o
n

S
a
m
p
l
i
n
g

S
u
p
p
l
i
e
s
Flow Injection Sampling Supplies
Flow Injection Amalgamation System
26
Flow Injection Amalgamation System
Provides increased sensitivity for the determination of
mercury by amalgamation of Hg on a Au/Pt gauze. Mercury
collected is quantitatively released by a controlled, rapid
heating of the gauze.
Components Part No. Each
Quartz Tube with Au/Pt Gauze B0193793 395
Glass Fiber Filter Holder B0507777 363
May be used in place of drying tube
Glass Fiber Filter, pkg. 20 B0507779 27
Drying Tube B0198104 54
5 Wash Flask, 10 mL B0505326 105
6 Connector, T-type B0198201 17
7 Sample Loop, 1000 L B0501000 55
8 PTFE Tubing B0198099 61
1.75 mm i.d., 250 mm length
8 PTFE Tubing B0198100 61
1.75 mm i.d., 450 mm length
Silicone Tubing B0018283 11
5 mm i.d., 1 m
Silicone Tubing B0070126 9
3 mm i.d., 1 m
Air Filter B0502706 15
One-way Valve B0198111 96
1
Amalgamation System and Supplies
Part No. Each
B0191090 5100
8
5
4
5
2
9 6
3
8
5
1
7
6
1
2
3
5
III
4
6
7
8
9
III
()
()
F
l
o
w

I
n
j
e
c
t
i
o
n

S
a
m
p
l
i
n
g

S
u
p
p
l
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Flow Injection Sampling Supplies
Flow Injection Furnace Supplies
27
The direct coupling of flow injection with a graphite furnace
atomic absorption automates on-line element preconcentration
in the graphite tube, improving detection limits for the hydride-
forming elements and for mercury by a factor of up to 500.
FIAS-Furnace Coupling Kit
For coupling a FIAS-400 with a 4110 ZL, AAnalyst 400
(with HGA-900), AAnalyst 600, AAnalyst 700, AAnalyst
800, or SIMAA
TM
6100/6000 Graphite Furnace System.
The kit consists of a sample transfer tube, a quartz pipette
tip, a 50 mL bottle Iridium standard
solution, and a FIAS-Furnace user guide.
FIAS-Furnace Sample
Transfer Tube*
Quartz Pipette Tip*
20 mm. (pkg.1)
Silicone Tube*
1 m.
* Included in the FIAS-Furnace Coupling Kit (B3140255)
FIAS-Furnace Coupling Kit and Supplies
Sample
Capillary
Graphite Tube
Gas/Liquid-Separator
Argon
NaBH
4
HCl
P1
P2
Waste
FIA Valve
Flow Diagram for FIAS-Furnace Coupling
Part No. Each
B3140255 654
Part No. Each
B0509612 119
Part No. Each
B0510032 35
Part No. Each
B0029796 4 ()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
F
l
o
w

I
n
j
e
c
t
i
o
n

S
a
m
p
l
i
n
g

S
u
p
p
l
i
e
s
Flow Injection Sampling Supplies
Flow Injection Preconcentration Kit and Supplies
28
PTFE Tubing Assemblies Flow Injection Sampling
Valves and Supplies
Components Part No. Each
FI Sampling Valve, 5-Port B0507914 714
FI Sampling Valve, 8-Port B0509095 1418
Valve Dismantling Tool B0509590 4
Threaded Plug B0500695 468
To close off port on
5-port valve
Peristaltic pump tubing has a wall thickness
of 0.84 mm unless noted otherwise.
Components Part No. Each
Tubing (pkg. 12) B0193161 37
1.52 mm i.d., Yellow/Blue
Tubing (pkg. 12) B0506058 37
0.76 mm i.d., Black/Black
Tubing (pkg. 12) B0507692 62
1 mm i.d., White/White
Resistant to organic solvents
Components Part No. Each
C
18
Preconcentration Column B0504047 689
PTFE column packed with silica-immobilized
C
18
Material. (Pkg.10)
XAD-8 Preconcentration Column B0504048 689
PTFE column packed with XAD-8 Material. (Pkg.10)
Cr Preconcentration Column B0509561 631
Alumina column for speciation of
Cr (III) and Cr (Vi). (Pkg.10)
In the PTFE tubing assemblies described
below, the numbers in parentheses refer to
the length of the tubing assembly and the
number of flanged ends with screw fittings.
Components Part No. Each
PTFE Tubing Assembly B0191059 29
Carrier or reagent container to peristaltic
pump tubing, 1 mm i.d. (700 mm x 1 flanged end)
PTFE Tubing Assembly B0191058 19
Manifold to manifold and to tubing adapter C,
1 mm i.d. (110 mm x 2 flanged ends)
PTFE Tubing Assembly B0501594 34
Valve to preconcentration column,
0.35 mm i.d. (60 mm x 2 flanged ends)
PTFE Tubing Assembly B0501595 64
3-dimensional reactor, 0.35 mm i.d.
(two flanged ends)
Components Part No. Each
Tubing Adapter A B0193342 12
Connects thin (1 to 2 mm i.d.) peristaltic
pump tubing with the PTFE tubing screw fittings
Tubing Adapter C B0196850 38
Connects to 3 mm waste tubing
Tubing Adapter G B0501580 71
For peristaltic pump tubing to merge
chelate and sample streams
Tubing Connector Type II B0196704 3
Connects two PTFE tubing screw fittings
Peristaltic Pump Tubing
Preconcentration Columns
2
7
8
9
1
1
1
3
4
5
6
Tubing Adapters and Connectors
A
C
G
II
A
A
3
A
A
3
9
5
5
4
4
G
C
II
6
7
8
C
2
1
()
()
()
()
()
29
Rely on PerkinElmer graphite
for consistent analytical results.
Every sample. Every day.
We Start With an Exclusive Grade of Graphite
The production of high-quality graphite
components requires stringent quality control.
Selection and careful control of raw materials are
extremely important.
The composition and the microstructure of the
base graphite material determines the resistivity
of the tube and its heating characteristics. To
ensure high quality and consistency, a specific
high-density base graphite material has been
developed for use with PerkinElmer graphite
furnace systems. This base graphite material is
used exclusively for the manufacturing of
PerkinElmers graphite components.
Trust Your Analysis to
Genuine PerkinElmer Graphite
Our Tubes Are Manufactured
and Tested to the Highest
Quality Specifications
During manufacturing, a comprehensive
quality testing programincluding
extensive mechanical, electrical,
thermal, and analytical testing
procedures is strictly followed.
Each lot of graphite tubes is tested to
demanding specifications for lifetime,
sensitivity, and precision.
Extensive testing ensures that all graphite
components shipped by PerkinElmer
provide consistent lot-to-lot performance.
Our Pyrolytic Coating Design
is Critical to Achieving
High Performance
The specified thickness of pyrolytic coating
applied to PerkinElmer graphite improves
the total resistance of the graphite tube and
the temperature distribution within the
tube. Improper pyrolytic coating can
shorten tube lifetime dramatically.
The microstructure and density of the
surface are important parameters for the
atomization kinetics of analyte elements.
Irreproducible surface qualities will cause
changes in the optimal drying, pyrolysis
and atomization temperatures, peak shape
and characteristic mass. PerkinElmers
coating specification and quality control
ensure consistency from tube to tube.
You Can Depend on
Our Extensive Experience
PerkinElmer has over three decades
of experience in the design and
development of graphite furnace
systems and materials. Years of
PerkinElmer development have
yielded the best possible graphite
for atomic absorption.
Any other graphite has not been
optimized for use with PerkinElmer
instruments and may yield
inaccurate analytical results.
Graphite Furnace
Graphite Tubes and Supplies
Graphite Furnace
Graphite Tubes and Supplies
30
Do Not Accept Imitations
Graphite components offered by other companies
often refer to the PerkinElmer part, implying that these
components are made from the same material and provide
equivalent performance. This is misleading, as these
imitation components are not made from the same
base graphite material, nor are they tested to the same
demanding quality control specifications. The different
base graphite material will alter the temperature
calibration, the heating rates, and the performance
characteristics.
Rely on Genuine PerkinElmer Graphite
Todays analysts expect exceptional analytical performance
from their graphite furnace atomic absorption spectrometers.
That performance must be stable and reproducible from
day to day with respect to sensitivity (characteristic mass),
accuracy, and precision.
The graphite tube, the heart of the graphite furnace, plays
a vital role in the overall stability of an analysis. In order
to assure stable analytical conditions from one atomization
cycle to the next, and from graphite tube to graphite tube,
all graphite parts contacts, tubes, and platforms
must be under strict quality control by both the instrument
manufacturer and the graphite manufacturer. PerkinElmer
graphite components continue to set the industry standard
for quality.
The proper performance, maintenance, and serviceability
of your graphite furnace system can be assured only
through the use of genuine, high-quality PerkinElmer
graphite components.
How is High-Quality Graphite Manufactured?

Select carefully chosen raw materials that are exclusive to PerkinElmer

Mill and mix the components with precision

Utilize the proper pressing techniques

Employ the correct heat treatments at carefully selected times

Purify materials at multiple times throughout the process

Apply special coating technology for pyrolytic products

Test and qualify graphite against rigorous PerkinElmer standards

Machine patented PerkinElmer designs using specialized techniques


G
r
a
p
h
i
t
e

F
u
r
n
a
c
e

T
u
b
e
s

a
n
d

S
u
p
p
l
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Graphite Furnace Tubes and Supplies
HGA Graphite Contact Cylinders, Tubes, and Supplies
31
The graphite contact cylinders used in the HGA

Graphite
Furnace are engineered for a precise fit so that variations
in electrical contact which might affect the analytical
performance are reduced to a minimum. The graphite
contacts are shaped so that they completely encase the
graphite tube. Thus, the graphite tube is located in a
defined inert environment, which ensures uniform
heating conditions and long tube lifetime.
Contact Cylinders for HGA-500/400 Furnaces
Includes left-hand Contact, right-hand Contact, Shield Ring.
Description Part No. Each
5 sets B0180363 492
Contact Cylinders for Zeeman HGA Furnaces
Includes left-hand Contact, right-hand Contact.
Description Part No. Each
1 set B0116823 130
5 sets B0180361 617
Contact Cylinders for
HGA-900/850/800/700/600/300 Furnaces
Includes left-hand Contact, right-hand Contact, Shield Ring.
Description Part No. Each
1 set B0128495 107
5 sets B3130086 506
Contact Cylinders Removal Tool
Description Part No. Each
For HGA-300/400/500/600/700/800 Furnaces B0098258 536
For HGA-600 Zeeman Furnaces B0127431 472
For AAnalyst 700 and HGA-850/900 B3121301 320
Graphite Tube Alignment Tools
Description Part No. Each
For Non-Zeeman Furnaces B0080112 80
For Zeeman HGA Furnaces B0120242 80
The Lvov Platform is a small plate of solid pyrocoated
graphite that is inserted into the graphite tube. It has a slight
depression in the center which can accommodate up to 50 L
of solution. The function of the Lvov Platform is to isolate
the sample from the tube walls to allow more reproducible
atomization of the sample through indirect heating. The
platform heats primarily by the radiation given off from the
tube walls. Sample vaporization and atomization occur after
the tube reaches a steady-state temperature.
Use of the Lvov Platform provides:
Vaporization into a higher temperature gas atmosphere
producing more free atoms, which reduce interferences
Longer tube life because aggressive samples are only
in contact with the solid pyrolytic graphite platform
Description Part No. Each
5-pack B0137112 104
20-pack B3001256 394
50-pack B0109324 935
100-pack N3110145 1765
Lvov Platforms
Contact Cylinders
For Non-Zeeman Furnaces
Part No. B0080112
For Zeeman HGA Furnaces
Part No. B0120242
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
G
r
a
p
h
i
t
e

F
u
r
n
a
c
e

T
u
b
e
s

a
n
d

S
u
p
p
l
i
e
s
32
Graphite Furnace Tubes and Supplies
HGA Graphite Contact Cylinders, Tubes, and Supplies
High-purity compounds minimize
the risk of contamination
Optimum graphite furnace program
can be used due to reduced
analyte volatility
Convenient, ready-to-use
Modifier Concentration Volume (mL) Part No. Each
Mg(No
3
)
2
1% Mg (as nitrate) 100 B0190634 71
Pd 1% Pd (as nitrate) 50 B0190635 249
NH
4
H
2
PO4 10% NH
4
H
2
PO4 100 N9303445 101
Pyrocoated Graphite Tubes (Grooved)
Internally grooved to accept Lvov Platforms.
Description Part No. Each
5-pack B0137111 237
20-pack B3001254 900
50-pack B0109322 2131
100-pack N3110146 4026
HGA Furnace Mirror
Graphite tubes with integrated platforms are machined from
one piece of graphite and are totally pyrocoated, providing
exceptional tube-to-tube reproducibility.
The spherically shaped platform
accommodates up to 50 L of sample.
Graphite tubes with integrated platforms:
Provide STPF conditions for volatile and nonvolatile refractory
elements due to the significantly higher heating rates of tube
and platform, which can be used for all elements
Offer an extra measure of convenience versus manually
inserting a separate platform
Provide longer life with many aggressive sample matrices,
such as concentrated acids
Pyrocoated Graphite Tubes with Integrated Platforms
Description Part No. Each
5-pack B3001262 317
20-pack B3001264 1138
100-pack N3110149 5400
Pyrocoated Graphite Tubes*
Description Part No. Each
5-pack B0105197 213
10-pack B0135653 403
20-pack B3000342 765
50-pack B0091504 1808
Description Part No. Each
50-pack B0070699 965
Matrix Modifiers for
Graphite Furnace AA
Pyrocoated Graphite Tubes (Grooved)
for use with Lvov Platforms
Cross-section of the PerkinElmer HGA graphite tube
with manually inserted Lvov platform.
Part No. Each
B0080259 83
Cross-section of the PerkinElmer HGA graphite tube
with integrated platform.
Uncoated Graphite Tubes*
Pyrocoated Graphite Tubes
with Integrated Platforms
* Not compatible with Lvov Platforms.
* Not compatible with Lvov Platforms.
Uncoated Graphite Tubes Part No. B0070699
Pyrocoated Graphite Tubes with
Integrated Platforms Part No. B3001262
()
()
()
()
()
()
G
r
a
p
h
i
t
e

F
u
r
n
a
c
e

T
u
b
e
s

a
n
d

S
u
p
p
l
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Graphite Furnace Tubes and Supplies
HGA Graphite Cooling Systems and Quartz Windows
33
HGA Circulatory Cooling System for HGA-800/850/900
Voltage Part No. Each
115 V, 60 Hz B3001124 4323
230 V, 50/60 Hz B3001123 4323
Glycerol
(85% for cooling systems), 1 L
The HGA Graphite Furnace Assembly is sealed at both ends
with easily removable quartz windows. This closed-furnace
design is a prerequisite for controlled and reproducible
internal analytical conditions.
Model Window Part No. Each
AAnalyst 700/HGA-850/900 Left- and Right-hand B0080850 109
Model Window (small window) Part No. Each
Zeeman 5X00 Right-hand
Zeeman 3030 Right-hand
HGA-300/400/500 Left- and Right-hand
HGA-600/700 Right-hand
HGA-800 Left-hand
B0066549 21
Model Window (large window) Part No. Each
Zeeman 3030, 5X00 Left-hand
HGA-600/700 Left-hand
HGA-800 Right-hand
B0115576 43
Components Part No. Each
O-Ring B0047209 2
Gasket* B0071145 1
Window B0066549 21
Window B0115576 43
Gasket** B0104342 2
* Use B0147153 on the HGA-800
** Use B0196825 on HGA-600s and HGA-700s installed after May 1990
5
4
3
2
1
Quartz Windows
Quartz Window Components
1
2
3
4
5
Circulatory Cooling System
Part No. Each
B3141064 29
HGA Circulatory Cooling System
Part No. B3001124
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
G
r
a
p
h
i
t
e

F
u
r
n
a
c
e

T
u
b
e
s

a
n
d

S
u
p
p
l
i
e
s
Graphite Furnace Tubes and Supplies
THGA Graphite Contact Cylinders, Tubes, and Supplies
34
The graphite contact cylinders are engineered for a precise
fit so that variations in electrical contact which might
affect the analytical performance are reduced to a
minimum. Contact cylinders with a modified injection
port area help to minimize condensation and improve
analytical performance with difficult matrices.
Standard THGA Contact Cylinders
Description Part No. Each
1 pair B0504035 174
5 pairs B0504036 824
Modified THGA Contact Cylinders
For improved analytical performance with samples that
have a high concentration of dissolved salts or matrices
with a high boiling point with transversely heated
graphite furnaces.
Description Part No. Each
1 pair B3002103 187
5 pairs B3002102 886
Accessories and Spare Parts
Description Part No. Each
O-Ring (behind contact cylinder, front and back) B0500748 1
Contact Cylinder Removal Tools B3120405 402
Standard THGA Graphite Tube
PerkinElmers unique, transversely-
heated graphite tube includes an
integrated platform. The exceptionally
uniform temperature distribution
obtained with transverse heating
significantly reduces or eliminates
condensation of the sample matrix
components and memory effects, and improves the
atomization efficiency for refractory elements.
Description Part No. Each
5-pack B3000641 600
20-pack B0504033 2156
100-pack N3110147 10200
Standard THGA Graphite Tube with End Cap*
For improved characteristic
mass with volatile and
medium refractory elements
such as Ag, As, Cd, Co, Cr
Cu, Pb, Se, and Tl, the THGA
graphite tubes with end caps
are recommended.
Improved detection limits for volatile and medium
refractory elements
Faster drying for complex matrices due to enlarged
dosing hole
Description Part No. Each
5-pack B3000653 612
20-pack B3000655 2200
* Not recommended for refractory elements such as V or Ba.
UltraClean THGA Graphite Tube
For the lowest possible detection limits, residual contaminant
levels may not be low enough to meet your requirements. For
the most demanding analyses, PerkinElmer offers UltraClean
THGA graphite tubes delivering exceptionally low levels of
contamination due to advanced high-temperature gas-phase
cleaning procedures. UltraClean graphite tubes offer
unmatched analytical advantages for special applications
such as the determination of extremely low traces of Na,
Ca, Fe, Cr, and Ni in ultra-clean reagents used in the
semiconductor industry, and ultra-trace analyses of
environmental, clinical, or food samples.
Key Benefits
UltraClean THGA graphite tubes have the lowest possible
contamination levels due to extensive high-temperature
gas-phase cleaning procedures
UltraClean THGA graphite tubes are tested and specified
for blank levels of Cr, Ni, V, Mo, Ti (<0.003 integrated
absorbance units) and Na, Fe, Al, Si, Ca (<0.0005 integrated
absorbance units)
Description Part No. Each
5-pack B3140361 647
20-pack B3140362 2326
Cross-section of the
PerkinElmer THGA
transversely-heated
graphite tube with
integrated platform
and end cap
Contact Cylinders
Graphite Tubes
()
()
()
()
()
()
G
r
a
p
h
i
t
e

F
u
r
n
a
c
e

T
u
b
e
s

a
n
d

S
u
p
p
l
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Graphite Furnace Tubes and Supplies
THGA Graphite Contact Cylinders, Tubes, and Supplies
35
High purity compounds minimize the risk of contamination
Optimum graphite furnace program can be used due to
reduced analyte volatility
Convenient, ready-to-use
Modifier Concentration Volume (mL) Part No. Each
Mg(No
3
)
2
1% Mg (as nitrate) 100 B0190634 71
Pd 1% Pd (as nitrate) 50 B0190635 249
NH
4
H
2
PO4 10% NH
4
H
2
PO4 100 N9303445 101
Circulatory Cooling System for use
with THGA Furnace Systems
230 V, 50/60 Hz.
Quartz Window for the THGA
O-Ring
For Furnace Window.
Rinse Funnel for Fume Extraction System
Used to aspirate water.
Spare Graphite Tip for the Fume Extraction System
(1 piece).
THGA Furnace Mirror
Used to optimize drying temperatures
and times.
THGA Graphite Tube Pliers
Matrix Modifiers for
Graphite Furnace AA
Spare Parts and Supplies
Part No. Each
B0198072 3890
Part No. Each
B0501236 13
Part No. Each
B0198005 120
Part No. Each
B0508836 13
Part No. Each
B0506722 24
Part No. Each
B0851900 85
Part No. Each
09907925 8
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
L
a
b
o
r
a
t
o
r
y

P
r
o
d
u
c
t
s
Laboratory Products
Filters, Regulators, and Supplies
36
Filters
Balston

Air Filter Assembly Type A-82


Specifically designed to
remove water, oil, and dirt
particles down to 0.6 microns
in diameter from compressed
air lines. It is recommended for
use with oil-type compressors,
and for removing moisture and
dirt particles from air supplied
by oil-less compressors.
Replacement Air Filter
Wilkerson

Air Dryer Filter


Provides clean air for burner
controls used with AA
spectrometers. It removes
entrained water, oil, and water
aerosols, and solid particles
from compressed air lines. The
pressure regulator reduces the
air pressure, which decreases
the relative humidity of the
air and prevents further
condensation. The final filter removes aerosols and particles
which are small enough to pass through the pre-filter. Oil,
if present, is collected on the coalescing-type final filter and
drips to the bottom of the bowl. The assembly consists of a
shut-off valve, a pre-filter with automatic drain, a pressure
reducing regulator with pressure gauge, a final filter, and a
final filter indicator.
Max Inlet Pressure: 150 psig
Replacement Filters
Replacements (Pre-filter) Part No. Each
Filter Elements 09923464 19
Filter Bowls N9302199 25
Replacements (Final Filter) Part No. Each
Filter Elements 09907120 47
Filter Bowls N9302199 25
Bowl O-ring Kit N9302197 45
Balston 95A Acetylene
Includes a Balston Grade
BQ filter cartridge to remove
liquid and solid contaminants
from the acetylene supply to
99.99% at 0.01 micron.
Max Working Pressure: 15 psig
Acetylene Replacement
Filter Cartridge
Parker Balston 73-099 AA Gas Purifier
A wall-mounted system designed
to purify the compressed air and
acetylene gases used in atomic
absorption. It consists of two
independent filtration systems,
one for compressed air and
one for acetylene. The unit
also has a flashback arrestor
on the acetylene line and a
pressure regulator on the
compressed air line.
The two-stage air filtration
assembly consists of a Balston Grade DX coalescing filter and
a Balston Grade BX coalescing filter. Together these filters
remove oil, water, and particulate contamination (99.99% at
0.01 micron) from the compressed air supply.
Replacement Cartridges
1st Air Filter Part No. Each
Replacement Cartridges N9301710 18
Replacement Seal Sets N9301712 17
2nd Air Filter Part No. Each
Replacement Cartridges N9301711 18
Replacement Seal Sets N9301712 17
Acetylene Filter Part No. Each
Replacement Cartridges N9301714 12
Replacement Seal Sets N9301715 10
Part No. Each
N0580531 281
Part No. Each
N0582251 42
Part No. Each
N9301399 312
Part No. Each
N9301714 12
Part No. Each
N9301398 1008
Part No. Each
00470652 555
()
()
()
()
()
()
()
()
()
()
()
L
a
b
o
r
a
t
o
r
y

P
r
o
d
u
c
t
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Laboratory Products
Filters, Regulators, and Supplies
37
Matheson Flashback Arrestor
Because acetylene is an extremely unstable gas, users
can experience flashbacks at the instrument burner head.
The flash arrestor prevents these potentially dangerous
flashbacks from reaching the regulator or cylinder.
Acetylene Max Operating Pressure: 15 psig
Positive shut-off of gas checks the reverse flow under all
conditions. Also stops gas supply when a flashback occurs.
Hose Assemblies
Hose assemblies for connecting fuel, air, and nitrous oxide
from supply to instrument.
Description Part No. Each
Acetylene, red, 3.7 m (12 ft.) long 00570559 80
Air/Argon, black, 3.7 m (12 ft.) long 00570567 80
Nitrous Oxide, blue, 3.7 m (12 ft.) long 00470258 116
Filter Cartridge for Fume Extraction Separator Trap
(pkg. 50)
Instrument Filters
Description Part No. Each
Filter for AA 100/300 09995097 21
Filter for AA 200/400/600/700/800 B0501696 21
Filter for AA 600/700/800 (80x80) B0502706 15
SIMAA 6100/6000
Rear filter. (pkg. 1)
Square Filter Pads
4100 ZL/4110 ZL, side and
back filters. (pkg. 1)
Aqueous and organic solutions as well as acids (including HF)
can be easily dispensed without the risk of sample contamination
when using the high-precision MiniDispenser.
Bottle Holder PP-250
Used to stabilize 250 mL
plastic bottles such as supplied
by Suprapur

and
Optima chemicals.
MiniDispenser
Preassembled and tested.
Includes GL45, S40, and
38-430 bottle adapters.
Replacement Valve Kit
For replacing MiniDispenser valves.
Part No. Each
N9300068 312
Hose Assemblies
Flash Arrestor
Acetylene, Red
Part No. 00570559
Air/Argon, Black
Part No. 00570567
Instrument Filters
Part No. Each
B0509065 37
Part No. Each
B0502706 15
Part No. Each
B0501252 3
MiniDispenser
Part No. Each
B0511806 59
Part No. Each
B0511778 201
Part No. Each
B0511779 130
()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
L
a
b
o
r
a
t
o
r
y

P
r
o
d
u
c
t
s
Laboratory Products
Filters, Regulators, and Supplies
38
Venting System
A venting system is
required to remove fumes
and vapors from the burner
compartment of atomic
absorption instruments.
Includes exhaust hood,
adapter, and blower.
Description Part No. Each
Blower and Vent Assembly 03030406 1218
Exhaust Hood 03031910 236
Acetylene Regulator
Includes an adapter
so that the pressure
regulator can be
connected to cylinders
requiring either CGA 300
or CGA 510 fittings and
a connector for attaching
the fuel hose assembly
supplied with the
instrument. Includes
hose assembly.
Max Inlet Pressure:
400 psig
Air Regulator
Regulator to cylinder
CGA no. 590. Includes
hose assembly.
Max Inlet Pressure:
3000 psig
Argon/Nitrogen Regulator
Can be used with Argon
or Nitrogen and has
a CGA 580 fitting. A
color-coded hose with
1/4-inch SWAGELOK

fittings is also included.


Max Inlet Pressure:
3000 psig
Nitrous Oxide Regulator
For use with gas
cylinders with a CGA 326
connection. Provides
pressure control from
350-520 kPA (50-75 psig)
and contains an integral
thermostatted heater to
prevent freezing of
the regulator diaphragm.
A color-coded hose with
suitable connectors at
each end is supplied
with the regulators to
provide connection to the
instrument gas controls.
Part No. Each
03030284 446
Part No. Each
03030204 848
Regulators
Part No. Each
03030106 446
Part No. Each
03030264 446
Venting System
Note: Does not include ducting.
PerkinElmer Service Engineers are
not permitted to install this unit.
()
()
()
()
()
PerkinElmers expertise in the design and
manufacture of light sources for atomic
absorption spectrometers traces back to
our original hollow cathode lamps, developed
nearly 40 years ago.
Genuine PerkinElmer
Hollow Cathode Lamps
for
Atomic Absorption
39
Lamps for Atomic Absorption
Lumina Hollow Cathode Lamps
PerkinElmer manufactures a full range of single-
element and multi-element hollow cathode lamps
and high-intensity electrodeless discharge lamps for
those elements for which they are more effective.
Every genuine PerkinElmer Lumina

lamp is designed
for use with, and tested on, our spectrometers to assure
compatibility and the highest performance. To prolong
the life of a Lumina hollow cathode lamp (HCL), we
produce lamps with larger internal volume so that
a greater supply of fill gas at optimum pressure is
available. The larger the lamp, the greater the inert
gas volume and the longer the lamp lifetime.
PerkinElmer offers a wide range of single-element and
multi-element HCLs, which are ideal for determining
most elements by atomic absorption spectroscopy.
For the Widest Selection of Elements
The basic components of a hollow cathode lamp (HCL) are a sealed glass
cylinder filled with an inert gas (argon or neon), an anode, a cathode, and
either glass or quartz end window. The cathode is a hollow cylinder of
the element whose spectrum is to be produced, or in some cases, an alloy
or carefully selected mixture of metals which do not spectrally interfere.
Hollow cathode lamps emit light by the following process: The fill gas is
ionized when an electrical potential is applied between the anode and
the cathode. The positively charged ions collide with the negatively
charged cathode and dislodge individual metal atoms in a process known
as sputtering. These sputtered metal atoms are excited through
impact with fill gas ions, and light of the specific wavelengths for that
element is emitted when the atom decays from the excited state back
to the more stable state.
PerkinElmer Exclusive 6/24 WARRANTY*
Lumina

Hollow Cathode Lamps


1. We warrant that during the first six months or after 5,000 milliampere-hours of operation,
whichever comes first, from initial date of shipment, the lamps will meet or exceed the
intensity and absorption specifications to which all new lamps are tested.
2. All our hollow cathode lamps are warranted to light and emit the spectra of the element
indicated for two years or 5,000 milliampere-hours of operation from the date of the
shipment, whichever comes first.
3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.
* The lamp warranty is void for lamps which sustain physical damage or are operated at power
levels substantially above or below the power level recommended on the lamp label. The lamp
warranty may vary in different countries.
Features and Benefits

Long Life: PerkinElmers larger


lamp volume results in longer
lamp lifetime

Automation: PerkinElmer coded


lamps allow automatic setup

Easy Installation: Its as simple


as sliding the lamp into the
instruments lamp bracket
or turret

Timers: Each Lumina


hollow cathode lamp includes
a milliampere-hour timer in its
base to monitor lamp usage

Complete Compatibility:
Lumina hollow cathode lamps
can be used with PerkinElmers
entire range of atomic absorption
spectrometers

Testing: Every lamp is thoroughly


tested before leaving the factory

Quality: Carefully selected


materials used in the
manufacturing of our lamps
avoid spectral interference

Design: Our design provides you


with the low detection limits
needed for your most difficult
determinations

Selection: PerkinElmer offers


a wide selection of single-element
and multi-element lamps

Easy To Order: Its easy to find


the right lamp for your analytical
needs simply use the selection
charts on page 40

Warranty: The performance of


every PerkinElmer lamp is
fully warranted
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
L
a
m
p
s

f
o
r

A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Lamps for Atomic Absorption
Lumina Hollow Cathode Lamps
40
Lumina coded hollow cathode lamps are available in two
series: with and without an Intensitron adapter cable.
Series N30501XX and N30502XX Lumina lamps
do not include an Intensitron adapter cable and are
designed to be used with PerkinElmers AAnalyst
TM
series of instruments.
Series N30503XX and N30504XX Lumina lamps
include an adapter cable that allows the lamps to be
recognized by the following instruments: SIMAA
TM
6100/6000, 5100 (PC), 4110 ZL, 4100, 4100 ZL, 3300,
2100, and 1100(B).
Lumina hollow cathode lamps may also be used with
all earlier AA spectrometers that do not have automatic
code reading capability by using an appropriate
adapter cable (refer to Adapter Cable on page 44).
Lumina Lamp
Lumina Plus Intensitron

Element Element Lamp Adapter


Name Symbol Part No. Each Part No. Each
Aluminum Al* N3050103 483 N3050303 573
Antimony Sb N3050170 573 N3050370 700
Arsenic As N3050105 700 N3050305 828
Barium Ba* N3050109 611 N3050309 738
Beryllium Be* N3050110 802 N3050310 930
Bismuth Bi N3050111 573 N3050311 675
Boron B* N3050108 636 N3050308 764
Cadmium Cd N3050115 547 N3050315 675
Calcium** Ca N3050114 509 N3050314 636
Chromium Cr N3050119 483 N3050319 611
Cobalt Co N3050118 420 N3050318 547
Copper*** Cu N3050121 420 N3050321 509
Dysprosium Dy* N3050122 483 N3050322 663
Erbium Er* N3050123 483 N3050323 663
Europium Eu* N3050124 483 N3050324 611
Gadolinium Gd* N3050129 483 N3050329 611
Gallium Ga N3050128 509 N3050328 611
Germanium Ge* N3050130 573 N3050330 700
Gold Au N3050107 573 N3050307 700
Hafnium Hf* N3050133 509 N3050333 663
Holmium Ho* N3050135 599 N3050335 663
Indium In N3050137 547 N3050337 636
Iridium lr N3050138 802 N3050338 930
Iron Fe N3050126 420 N3050326 509
Lanthanum La* N3050141 636 N3050341 663
Lead Pb N3050157 611 N3050357 738
Lithium Li N3050142 509 N3050342 636
Magnesium** Mg N3050144 483 N3050344 611
Manganese Mn N3050145 509 N3050345 636
Mercury Hg N3050134 547 N3050334 675
Molybdenum Mo N3050146 483 N3050346 573
Neodymium Nd* N3050150 483 N3050350 663
Nickel Ni N3050152 420 N3050352 509
Niobium Nb* N3050149 483 N3050349 573
Palladium Pd N3050158 611 N3050358 738
* This element requires a nitrous oxide-acetylene flame.
** To measure secondary lines below 230 nm, choose the Ca/Mg/Zn lamp
with quartz window.
*** To measure secondary lines below 230 nm, choose the Cu/Fe/Mn/Zn lamp
with quartz window.
Lumina Lamps and Lamps with Adapters
() ()
L
a
m
p
s

f
o
r

A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Lamps for Atomic Absorption
Lumina Hollow Cathode Lamps
41
Lumina Lamp
Lumina Plus Intensitron

Element Element Lamp Adapter


Name Symbol Part No. Each Part No. Each
Phosphorus P* N3050155 738 N3050355 866
Platinum Pt N3050162 675 N3050362 802
Potassium K N3050139 509 N3050339 611
Praseodymium Pr* N3050161 599 N3050361 663
Rhenium Re* N3050165 483 N3050365 759
Rhodium Rh N3050166 675 N3050366 802
Ruthenium Ru N3050168 738 N3050368 866
Samarium Sm* N3050174 490 N3050374 663
Scandium Sc* N3050171 573 N3050371 700
Selenium Se N3050172 611 N3050372 738
Silicon Si* N3050173 547 N3050373 675
Silver Ag N3050102 483 N3050302 573
Sodium Na N3050148 547 N3050348 675
Strontium Sr N3050176 547 N3050376 675
Tantalum Ta* N3050177 483 N3050377 611
Tellurium Te N3050180 611 N3050380 738
Terbium Tb* N3050178 547 N3050378 663
Thallium Tl N3050183 547 N3050383 675
Thulium Tm* N3050184 636 N3050384 764
Tin Sn N3050175 547 N3050375 675
Titanium Ti* N3050182 420 N3050382 547
Tungsten W* N3050187 445 N3050387 547
Vanadium V* N3050186 445 N3050386 573
Ytterbium Yb* N3050190 509 N3050390 663
Yttrium Y* N3050189 483 N3050389 611
Zinc Zn N3050191 573 N3050391 700
Zirconium Zr* N3050192 445 N3050392 573
*This element requires a nitrous oxide-acetylene flame.
() ()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
L
a
m
p
s

f
o
r

A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Lamps for Atomic Absorption
Lumina Hollow Cathode Lamps
42
Two-Element Lamps
Three-Element Lamps
Four-Element Lamps
Lumina Multi-Element Hollow Cathode Lamps
Lumina Lamp
Lumina

Plus Intensitron

Element Element Lamp Adapter


Name Symbol Part No. Each Part No. Each
Ag-Au N3050201 509 N3050401 614
Silver Ag
Gold Au
Ca-Mg* N3050202 611 N3050402 738
Calcium Ca
Magnesium Mg
Ca-Zn N3050203 636 N3050403 764
Calcium Ca
Zinc Zn
K-Na N3050204 611 N3050404 700
Potassium K
Sodium Na
Pt-Ru N3050205 802 N3050405 930
Platinum Pt
Ruthenium Ru
Sn-Te N3050206 611 N3050406 663
Tin Sn
Tellurium Te
Al

-Ca-Mg* N3050207 611 N3050407 738


Aluminum Al
Calcium Ca
Magnesium Mg
Ca-Mg-Zn N3050208 675 N3050408 802
Calcium Ca
Magnesium Mg
Zinc Zn
Cu-Fe-Ni N3050209 611 N3050409 738
Copper Cu
Iron Fe
Nickel Ni
* To measure secondary lines below 230 nm, choose the Ca/Mg/Zn lamp with
quartz window or the Ag, Al, Cr, Cu, Fe, Mg, or Al, Ca, Cu, Fe, Mg, Si, Zn
lamps with quartz windows.

This element requires a Nitrous Oxide-Acetylene flame.


Ag-Cr-Cu-Ni N3050210 636 N3050410 802
Silver Ag
Chromium Cr
Copper Cu
Nickel Ni
Al-Cu-Fe-Ti

N3050211 547 N3050411 675


Aluminum Al
Copper Cu
Iron Fe
Titanium Ti
Cu-Fe-Mn-Zn N3050212 611 N3050412 738
Copper Cu
Iron Fe
Manganese Mn
Zinc Zn
Five-Element Lamps
Six-Element Lamps
Seven-Element Lamps
Lumina Lamp
Lumina Plus Intensitron
Element Element Lamp Adapter
Name Symbol Part No. Each Part No. Each
Ag-Cr-Cu-Fe-Ni N3050213 611 N3050413 802
Silver Ag
Chromium Cr
Copper Cu
Iron Fe
Nickel Ni
Co-Cr-Cu-Mn-Ni N3050214 611 N3050414 738
Cobalt Co
Chromium Cr
Copper Cu
Manganese Mn
Nickel Ni
Co-Cu-Fe-Mn-Mo N3050215 636 N3050415 764
Cobalt Co
Copper Cu
Iron Fe
Manganese Mn
Molybdenum Mo
Ag-Al

-Cr-Cu-Fe-Mg N3050216 611 N3050416 738


Silver Ag
Alumiunum Al
Chromium Cr
Copper Cu
Iron Fe
Magnesium Mg
Co-Cr-Cu-Fe-Mn-Ni N3050217 611 N3050417 738
Cobalt Co
Chromium Cr
Copper Cu
Iron Fe
Manganese Mn
Nickel Ni
Al*-Ca-Cu-Fe-Mg-Si

-Zn N3050218 611 N3050418 738


Aluminum Al
Calcium Ca
Copper Cu
Iron Fe
Magnesium Mg
Silicon Si
Zinc Zn
() () () ()
L
a
m
p
s

f
o
r

A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Lamps for Atomic Absorption
Lumina Hollow Cathode Lamp Coded Adapters
43
Lumina Lamp with Intensitron Adapter Cable for use with
Models SIMAA 6100/6000, 5100 (PC), 4110 ZL, 4100,
4100 ZL, 3300, 2100, and 1100(B).
Lamp Adapters
These adapters allow Lumina HCLs to be
used on PerkinElmers wide range of atomic
absorption spectrometers.
Coded Lumina Adapters
Element Element
Symbols Part No. Each Symbols Part No. Each
Ag N3050702 74 Re N3050765 74
Al N3050703 74 Rh N3050766 74
As N3050705 74 Ru N3050768 74
Au N3050707 74 Sb N3050770 74
B N3050708 74 Sc N3050771 74
Ba N3050709 74 Se N3050772 74
Be N3050710 74 Si N3050773 74
Bi N3050711 74 Sn N3050775 74
Ca N3050714 74 Sr N3050776 74
Cd N3050715 74 Ta N3050777 74
Co N3050718 74 Tb N3050778 74
Cr N3050719 74 Te N3050780 74
Cu N3050721 74 Ti N3050782 74
Dy N3050722 74 Tl N3050783 74
Er N3050723 74 V N3050786 74
Fe N3050726 74 W N3050787 74
Ga N3050728 74 Y N3050789 74
Gd N3050729 74 Zn N3050791 74
Ge N3050730 74 Zr N3050792 74
Hg N3050734 74 Ag-Au N3050801 74
Ho N3050735 74 Ca-Mg N3050802 74
In N3050737 74 Ca-Zn N3050803 74
Ir N3050738 74 K-Na N3050804 74
K N3050739 74 Pt-Ru N3050805 74
La N3050741 74 Sn-Te N3050806 74
Li N3050742 74 Al-Ca-Mg N3050807 74
Mg N3050744 74 Ca-Mag-Zn N3050808 74
Mn N3050745 74 Cu-Fe-Ni N3050809 74
Mo N3050746 74 Ag-Cr-Cu-Ni N3050810 74
Na N3050748 74 Al-Cu-Fe-Ti N3050811 74
Nb N3050749 74 Cu-Fe-Mn-Zn N3050812 74
Nd N3050750 74 Ag-Cr-Cu-Fe-Ni N3050813 74
Ni N3050752 74 Co-Cr-Cu-Mn-Ni N3050814 74
P N3050755 74 Co-Cu-Fe-Mn-Mo N3050815 74
Pb N3050757 74 Ag-Al-Cr-Cu-Fe-Mg N3050816 74
Pd N3050758 74 Co-Cr-Cu-Fe-Mn-Ni N3050817 74
Pr N3050761 74 Al-Ca-Cu-Fe-Mg-Si-Zn N3050818 74
Pt N3050762 74
() ()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
L
a
m
p
s

f
o
r

A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Lamps for Atomic Absorption
Non-Coded Hollow Cathode Lamp Adapters
44
Coded Intensitron

Lamp Plug Adapter


Allows coded Intensitron HCLs (N06612XX series, 12 pin)
to be used with PerkinElmer atomic absorption
instruments with non-coded lamp
connectors (9 pin).
Lumina Lamp Plug Adapter
Allows Lumina HCLs (N305XXXX series, 4 pin)
to be used with PerkinElmer atomic absorption
instruments with non-coded lamp
connectors (9 pin).
Non-Coded Intensitron Lamp Plug Adapter
Allows non-coded Intensitron hollow cathode lamps
(030360XX series, 9 pin) to be used with the Models 5100
(PC), 3300, and 4100ZL (12 pin).
Non-Coded Intensitron Lamp Plug Adapter
Allows non-coded Intensitron lamps (03036XXX
series, 9 pin) to be used with AAnalyst
instruments (4 pin).
Non-Coded Intensitron Lamp Plug Adapter
Allows non-coded Intensitron HCLs (030360XX
series, 9 pin) to be used with Models 4100, 4100 ZL,
2100, and 1100(B) (12 pin). Not for use
on SIMAA 6100/6000.
Universal Coded Intensitron Lamp Plug Adapter
Allows coded lamps (N06612XX series, 12 pin) to be
used with AAnalyst instruments (4 pin); however, an
AAnalyst spectrometer does not recognize
their coding.
Lamp Plug Adapters
Part No. Each
N0660123 147
Part No. Each
N3050198 41
Part No. Each
N0660122 147
Part No. Each
N3050197 41
Part No. Each
B0156094 236
Part No. Each
N3050196 45
()
()
()
()
()
()
L
a
m
p
s

f
o
r

A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Lamps for Atomic Absorption
Supplies
45
For Instrument Source
Models Type Part No. Each
AAnalyst 100/300, Deuterium N0370119 765
3300, 3110, 3100
AAnalyst 200/400 Deuterium B3150169 304
AAnalyst 700/800 Deuterium B0148615 765
2280, 2380, 280, 380 Deuterium 00570194 695
3030(B)* Deuterium 00570194 695
3030(B)** Deuterium B0127014 318
4000, 5000, 5100, 5100 (PC), Tungsten-halide C0550500 69
Zeeman/5000, Zeeman/5100 (PC)
4100, 2100, 1100(B) Deuterium B0148615 765
For all instruments except the AAnalyst series, we recommend that an
authorized PerkinElmer Service Engineer install your Background Corrector
Source. Installation is not included in the price.
* For instruments with 10-digit serial numbers
** For instruments with 4-digit serial numbers
SIMAA 6100/6000 Quick-Change
Lamp Mount Assembly
Small Diameter Lamp Adapter Kit
Permits the use of hollow cathode lamps of smaller diameter
than the PerkinElmer 2 in. diameter hollow cathode lamps
used in PerkinElmer atomic absorption spectrometers.
Red Filter
Linearizes working curves for potassium, lithium, rubidium,
and cesium. Recommended for Rb and Cs determinations by
flame emission. Passes only wavelengths longer than 650 nm.
Many PerkinElmer atomic absorption spectrometers are
equipped with a filter holder for easy use.
Part No. Each
02901518 70
Part No. Each
N3051050 152
Part No. Each
B3000656 166
Small Diameter Lamp Adapter Kit Part No. N3051050
Background Corrector Sources
Supplies
Background Corrector Source
(For AAnalyst 100/300 and models
3300, 3110, 3100)
Part No. N0370119
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
Lamps for Atomic Absorption
System 2 EDL Lamps
46
While hollow cathode lamps are an ideal source
for determining most elements by atomic
absorption, for volatile elements we recommend
the use of electrodeless discharge lamps.
System 2 Electrodeless
Discharge Lamps
Maximum Intensity and Long Life
EDLs provide greater light output and longer life than
corresponding HCLs. For certain elements, such as Arsenic
and Selenium, EDLs will also provide improved sensitivity
and lower detection limits. System 2 electrodeless discharge
lamps provide the optimized spectral output needed to get
the maximum performance from PerkinElmer atomic
absorption spectrometers.
Electrodeless Discharge Lamps For Greater Brightness
EDLs are typically much brighter and, in some cases,
provide better sensitivity than comparable HCLs. EDLs are
preferred for certain volatile elements. They offer better
precision and lower detection limits for analyses that are
noisy due to weak hollow cathode emission. PerkinElmer
System 2 EDLs consist of the element or a salt of the
element sealed in a quartz bulb containing an inert
gas atmosphere. When an RF field of sufficient power is
applied, the inert gas is ionized and the coupled energy
vaporizes the element and excites the atoms inside the bulb,
resulting in the emission of the characteristic spectrum.
PerkinElmers System 2 EDLs
Consist of two major components: a dual-channel power supply with
matched dual RF driver assemblies, which allows simultaneous,
independent operation of two EDLs, and the interchangeable lamp
sleeves. The lamp sleeve contains the pre-aligned bulb for the element
of interest. The sleeve has the same exterior dimensions as the
PerkinElmer HCLs, allowing System 2 EDLs to be used in the same
lamp mounts and turrets.
System 2 EDLs are as easy-to-use as an HCL. Just install the lamp, turn it
on, and set the current. Changing lamps requires only seconds because
the pre-aligned bulbs require no additional adjustment.
System 2 EDLs include two coded adapter plugs that allow automatic
spectrometer set-up for those PerkinElmer atomic absorption
spectrometers with automatic lamp code reading capabilities.
To ensure operator safety, a built-in interlock prevents lamp operation if
the lamp is not properly installed.
The PerkinElmer Exclusive WARRANTY*
System 2 Electrodeless Discharge Lamps
1. We warrant that during the first six months or after 500 hours of operation, whichever comes
first, from initial date of shipment, the lamps will meet or exceed the intensity and absorption
specifications to which all new lamps are tested.
2. All our Electrodeless Discharge Lamps are warranted to light and emit the spectra of the
element indicated for two years or 1,000 hours of operation from the date of the shipment,
whichever comes first.
3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.
* The lamp warranty is void for lamps that sustain physical damage or are operated at power
levels substantially above or below the power level recommended on the lamp label.
The lamp warranty may vary in different countries.

Brightness: EDLs are much brighter and, in some cases, provide better
sensitivity than comparable hollow cathode lamps

Precision: EDLs offer lower detection limits and are preferred for
analyses that are noisy due to weak hollow cathode emission

Long Life: System 2 EDLs are long-lived for exceptional


cost-effectiveness

Automation: PerkinElmer coded lamps allow automatic set-up on


systems with automated turret

Quality: Carefully selected materials used in the manufacturing of our


lamps avoid spectral interference

Testing: Every lamp is thoroughly tested

Design: Our design provides you with the low detection limits needed
for your most difficult determinations

Warranty: The performance of every PerkinElmer lamp is fully warranted*


Features and Benefits
L
a
m
p
s

f
o
r

A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Lamps for Atomic Absorption
System 2 EDL Lamps
47
System 2 EDL Lamps and Adapters
The PerkinElmer Exclusive WARRANTY*
System 2 Electrodeless Discharge Lamps
1. We warrant that during the first six months or after 500 hours of operation, whichever comes first, from initial date of shipment, the lamps
will meet or exceed the intensity and absorption specifications to which all new lamps are tested.
2. All our Electrodeless Discharge Lamps are warranted to light and emit the spectra of the element indicated for two years or 1,000 hours
of operation from the initial date of shipment, whichever comes first.
3. If any lamp fails before the expiration of the warranty period, it will be replaced free of charge.
* The lamp warranty is void for lamps that sustain physical damage or are operated at power levels substantially above or below the power level
recommended on the lamp label. The lamp warranty may vary in different countries.
AAnalyst
System 2 Coded Intensitron

Element Element EDL Adapter


Symbol Name Part No. Each Part No. Each
As Arsenic N3050605 587 N3050860 45
Bi Bismuth N3050611 587 N3050861 45
Cd Cadmium N3050615 587 N3050862 45
Cs Cesium N3050620 587 N3050863 45
Ge* Germanium N3050630 587 N3050864 44
Hg Mercury N3050634 587 N3050865 45
P* Phosphorus N3050655 587 N3050866 45
Pb Lead N3050657 547 N3050867 45
Rb Rubidium N3050664 587 N3050868 45
Sb Antimony N3050670 587 N3050869 45
Se Selenium N3050672 587 N3050870 45
Sn Tin N3050675 587 N3050871 45
Te Tellurium N3050680 587 N3050872 44
Tl Thallium N3050683 587 N3050873 45
Zn Zinc N3050691 587 N3050874 45
* This element requires a Nitrous Oxide-Acetylene flame
Note: System 2 EDLs come with two coding plugs: a coding plug compatible
with the AAnalyst series of instruments and a coding plug compatible with
earlier instruments having coding capability; for example, the Models SIMAA
6100/6000, 5100 (PC), 4110 ZL, 4100 ZL, 4100, 3300, 2100, and 1100(B).
EDL lamps are compatible with all PerkinElmer atomic absorption
spectrometers except the Models 103, 107, 290, 290B, and 280.
() ()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
L
a
m
p
s

f
o
r

A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Lamps for Atomic Absorption
System 2 EDL Lamp Supplies and Accessories
48
Driver Assembly Adapter Cable
Allows System 2 EDL drivers
(03030793 and 03030997) to be
used on an AAnalyst 200/400.
Extension Cable
Increases length of cable on the
AAnalyst 600/700/800, SIMAA
6100/6000, and 4110 ZL System 2 EDL
Driver Assembly to the same length as
those on standard driver assemblies.
System 2 EDL Modulation Cable
Connects the power supply to the instrument.
(Included with System 2 EDL Power Supply.)
Description Part No. Each
For all instruments (except AAnalyst 100/300) 03030791 185
requiring external EDL modulation
For AAnalyst 100/300 N0410100 153
Included with System 2 Power Supply
EDL Driver Assemblies
Description Part No. Each
For AAnalyst 200/400 N3150131 886
For AAnalyst 600/700/800, SIMAA 4110 ZL 03030997 886
(short cable)
For all models except AAnalyst 600/700/800, 03030793 976
SIMAA 4110 ZL (long cable)
For use with systems that do not have built-in power
supplies. Provides both continuous or modulated operation
of System 2 EDLs. Includes two independently powered
channels with continuously adjustable power output
for each channel, two driver assemblies (03030793),
and modulation cables (03030791 and N0410100).
Description Part No. Each
Power Supply 115 V, 50/60 Hz FCC/VDE approved 03030952 3686
Power Supply 230 V, 50 Hz VDE approved 03030972 3686
EDL Driver Assemblies
EDL Accessories
Note: EDL System 2 Power Supplies are not
compatible with earlier System 1 EDLs
System 2 EDL Power Supply
Part No. Each
N3150303 29
Part No. Each
03030998 74
EDL Driver Assembly
Part No. 03030997
System 2 EDL Power Supply
Part No. 03030952
()
()
()
()
()
M
e
r
c
u
r
y
/
H
y
d
r
i
d
e

S
y
s
t
e
m
s

a
n
d

S
u
p
p
l
i
e
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Mercury/Hydride Systems and Supplies
MHS, Quartz Cells, and Supplies
49
MHS-15
Mercury/Hydride Systems are well proven accessories for
high-sensitivity determinations of mercury and metallic
hydride-forming elements, including As, Se, Sb, Te, Bi
and Sn by atomic absorption spectroscopy.

Complete separation of the


element being studied
from its sample matrix

Simple, highly specific


operating procedures

Reliable pneumatic control


of carrier gas and transport
of metallic vapors to the
quartz cell

Conveniently stands
adjacent to the sample
compartment of the
AA spectrometer
MHS-15 Detection Limits
Detection Limit* Detection Limit*
Absolute (ng) Relative (g/L)
Element (in 10 mL volume) (in 50 mL volume)
As 1.0 0.02
Se 1.0 0.02
Bi 2.0 0.10
Sb 5.0 0.10
Te 2.0 0.05
Hg 1.0 0.02
* EDL lamps were used for all elements.
MHS-15 Mercury/Hydride System
Manually operated system for the high-sensitivity
determination of Hg and hydride-forming elements.
Includes analyzer with sample flask, reagent reservoir,
quartz cell, and cell holder. Switch allows selection of
NaBH
4
or SnCl
2
reductant solution. No electrical
connections are required.
Quartz Cell for MHS-10 and MHS-15
Complete with graphite cooling
rings and silicone rubber sleeves.
Quartz Cell for MHS-20
Description Part No. Each
With Windows B0097693 1339
Without Windows B0097694 912
Quartz Window for
MHS-20 Quartz Cells
Universal Quartz Cell Holder
To mount MHS-10 or MHS-15 quartz
cell on burner system.
For MHS-10/15/20
Description Part No. Each
Flashback Arrestor B0098640 74
Graphite Cooling Ring for Quartz Cells* B0094413 37
Immersion Tube (Pipette Tip) B0094138 21
Reductant Reservoir (with cap) B0087354 147
Reductant Reservoir (without cap) B0094032 16
Sample Flask** B0094321 38
Silicone Sleeve for Quartz Cells B0098453 1
Transfer Hose B0094140 8
Supplies
Part No. Each
B3140760 2439
Part No. Each
B3000350 338
* For MHS-10 and MHS-15 only.
** Specially formed polypropylene reaction vessel with cover.
Quartz Cells Mercury/Hydride System
Part No. Each
B0094415 386
Quartz Cell for MHS-10/15
Part No. B0094415
Part No. Each
B0098452 338
Quartz Cell for MHS-20
Part No. B0097693
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
Sample Preparation Systems
High Pressure Asher System
50
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
The Anton Paar HPA-S is a high-performance digestion
system. Using hermetically closed vessels and applying
a maximum temperature of up to 320 C, the HPA-S
rapidly decomposes even the most complex samples.
The HPA-S provides superior digestion quality.
Complete sample mineralization
Minimum organic residue
No elemental losses
No contamination
The HPA-S can be used with a variety of different sized
vessels, making it ideally suited for many different
sample types and analytical applications.
The HPA-S can digest up to 21 samples simultaneously.
The high temperature and pressure is applied in a
hermetically closed system, and the quick and efficient
cooling at the end of the digestion keeps the total
digestion time short.
The samples and reagents are placed in vessels which
are then inserted into the heating block and placed into
the autoclave chamber of the HPA-S. The chamber is then
hermetically closed with a quick-lock lid and pressurized
with nitrogen. Starting at 100 bar (1475 psi), the pressure
rises with increasing temperature up to 130 bar (1920 psi).
This pressure ensures a tight seal during decomposition,
despite the rapidly increasing pressure due to the reaction
process. The system is conventionally heated using a
preselected temperature program.
High Pressure Asher
System Supplies
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
51
Sample Preparation Systems
High Pressure Asher System Supplies
Heat trays are heating blocks for insertion of reaction
vessels into the HPA-S pressure chamber.
Heat Tray for 5 Vessels
Aluminum block for insertion of five
quartz digestion vessels 90 mL.
Heat Tray for 6 Vessels
Aluminum block for insertion of six
(glassy carbon) digestion vessels 20 mL.
Heat Tray for 7 Vessels
Aluminum block for insertion of seven
quartz digestion vessels 50 mL.
Heat Tray for 14 Vessels
Aluminum block for insertion of
14 quartz digestion vessels 15 mL.
Heat Tray for 21 Vessels
Aluminum block for insertion of
21 quartz digestion vessels 15 mL.
Reaction Vessel Part No. Each Req. Lid Part No. Each
15 mL Quartz B0511516 76 16 mm B0511517 42
50 mL Quartz B0511514 156 22 mm B0511515 69
90 mL Quartz B0511513 196 22 mm B0511515 69
20 mL Glassy Carbon B0511518 330 B0511519 70
Reaction vessel racks are made of PVC and are
used to hold reaction vessels.
15 mL Reaction Vessel Rack
PVC rack for holding up to 14
15 mL reaction vessels.
20 mL Reaction Vessel Rack
PVC rack for holding up to six 20 mL
glassy carbon reaction vessels.
50 mL Reaction Vessel Rack
PVC rack for holding up to seven
50 mL (or older 30 mL) reaction vessels.
90 mL Reaction Vessel Rack
PVC rack for holding up to five
90 mL reaction vessels.
Reaction vessel sets are complete and include reaction vessels,
lids, heat tray, vessel rack, and PTFE tape for vessel closure.
5 x 90 mL Quartz Reaction Vessel Set
Used for the digestion of five samples
(maximum weight 1.5 g each) in
90 mL quartz vessels.
6 x 20 mL Glassy Carbon Reaction Vessel Set
Used for the digestion of six samples
(maximum weight 0.8 g each) in
20 mL glassy carbon vessels.
7 x 50 mL Quartz Reaction Vessel Set
Used for the digestion of seven samples
(maximum weight 0.8 g each) in
50 mL quartz vessels.
14 x 15 mL Quartz Reaction Vessel Set
Used for the digestion of 14 samples
(maximum weight 0.2 g each) in
15 mL quartz vessels.
Heat Trays
Part No. Each
B0511522 604
Part No. Each
B0511523 375
Part No. Each
B0511601 627
Reaction Vessel Racks
Part No. Each
B0511602 627
Reaction Vessels and Lids
Reaction Vessel Sets
Part No. Each
B0511524 98
Part No. Each
B0511527 98
Part No. Each
B0511526 98
Part No. Each
B0511525 98
Part No. Each
B0511504 2582
Part No. Each
B0511505 3040
Part No. Each
B0511502 1980
Part No. Each
B0511503 2380
Part No. Each
B0511603 710
()
()
()
()
()
() ()
()
()
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
Sample Preparation Systems
High Pressure Asher System Supplies
52
Back-up Ring for O-Ring
Special back-up ring made of
reinforced PTFE compound located
behind O-Ring B0511528.
Extraction Tool
Tool for removing heat trays from
the HPA-S pressure chamber.
O-Ring 107 x 5 FPM with FEP Coating
Special O-Ring for hermetically sealing
the high-pressure chamber safety lid.
PTFE Tape
Analytically pure PTFE tape for
positioning the lids on the reaction
vessels. The roll is 6.5 m.
Rupture Disk, DN 15
Made of corrosion-resistant Inconel

alloy with a burst


pressure of 180 bar. This allows for overpressure relief in
case of heavy explosions inside the HPA-S. Replace rupture
disk after approximately 750 cycles.
Support Ring, PEEK
Located behind the back-up ring (B0511529), this support
ring gives mechanical stability
to the entire seal assembly.
Wrapping Tool for PTFE Tape
Tool for closing the HPA-S vessels
with their lids using PTFE tape by
applying a special wrapping technique.
Supplies
Part No. Each
B0511529 20
Part No. Each
B0511512 310
Part No. Each
B0511528 56
Part No. Each
B0511507 17
Part No. Each
B0511511 168
Part No. Each
B0511530 117
Part No. Each
B0511506 890
()
()
()
()
()
()
()
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Sample Preparation Systems
Multiwave
53
Multiwave Accessories and Supplies
The Multiwave can be used with a wide variety of reaction vessels allowing the application of optimum reaction conditions
for almost every type of sample. The table below provides an overview of all the available reaction vessel assemblies.
Operation Maximum Maximum Applicable Typical Sample Maximum Filling
Type* Volume Material Pressure Pressure Temperature Rotor Type Weight Volume Part No. Each
HQ20 20 mL Quartz 75 bar 130 bar 300 C 6-position 10-200 mg 6 mL
HQ50 50 mL Quartz 75 bar 130 bar 300 C 6-position 100-1000 mg 20 mL B0502197 1721
HF50 50 mL TFM 75 bar 130 bar 260 C 6-position 50-500 mg 20 mL B0511677 1041
MF100 100 mL TFM (PFA) 30 bar 70 bar 260 C 6-position 100-1500 mg 50 mL B0511541 1180
LF100 100 mL PFA 20 bar 70 bar 230 C 12-position 100-1000 mg 50 mL B3140380 545
*Type definition: HQ50
Volume: 20, 50, 100 mL
Material: QQuartz
FFluorpolymer (TFM or PFA)
Pressure: HHigh
MMedium
LLow
HQ20
Characteristics
Small, high temperature vessel for analysis of
micro-samples of a few mg, for ultratrace analysis
Typical Applications
Pharmaceuticals
Biological and forensic microsamples
Biopolymers
HQ50
Characteristics
High temperature vessel for organic material,
for Hg detection, and for ultratrace analysis
Typical Applications
Food (high fat)
Plastics, Fibers
Oil, Grease, Coal
Pigments
HF50
Characteristics
For high pressure (HF) applications
of difficult organics and inorganics
Typical Applications
Semiconductor
Ceramics
Oxides
Geological material
MF100
Characteristics
Large vessel for versatile applications,
for combined organic-inorganic samples
Typical Applications
Soil, sediments
Ashes, slags
Metals, ores
Glass, quartz
LF100
Characteristics
Vessel with high over-pressure tolerance,
for high throughput of easy samples
Typical Applications
Water, effluent
Metals, alloys
Plant material
Beverages
Multiwave shipped prior to January 2002
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
Sample Preparation Systems
Multiwave
54
Reaction vessel assemblies include a reaction vessel, screw cap and (where appropriate) liner, support vessel,
plug safety disk, base plate, and jacket.
Reaction Vessel Assemblies
Item Description HQ20 HQ50 HF50 MF100 LF100 Part No. Each
Quartz vessel Q20 (20 mL)

B0511538
549
Quartz vessel Q50EW (50 mL)*

B0511674
643
Liner F50

B0511675
152
Liner F100
A
B0511532
102
Liner F100-PFA
A
B0511678
57
Supporting vessel 50

B0511676
230
Supporting vessel 100

B0511533
168
Supporting vessel with thread

B3140382
164
Plug

B0502201
123
Plug B

B0511539
271
Safety Disk H

B0502202
13
Safety Disk M

B0511535
12
Seal 25, pkg. 6

B0502203
135
Seal 40, pkg. 6

B0511534
139
Vessel base plate

B0502204
148
Bomb jacket PEEK

N/A
Screw cap PEEK

N/A
Screw cap L PEEK

B3140383
234
R
C
B
I
K
H
L
E
F
D
Q
M
P
N
J
O
A
G
* B0511674 replaces former B0502198, quartz vessel, 50 mL
Part of respective pressure vessel type
A possible alternative item
C
D
O
P
I
B
E
H
HF50 Part No. B0511677
High Pressure TFM
Reaction Vessel Assembly
C
D
E
H
A
I
B
C
F
E
H
I
B
G
HQ50 Part No. B0502197
High Pressure Quartz
Reaction Vessel Assembly
HQ20 High Pressure Quartz
Reaction Vessel Assembly
R
D
L
K
N
Q
LF100 Part No. B3140380
Low Pressure PFA
Reaction Vessel Assembly
C
L
M
B
D
K
J
MF100 Part No. B0511541
Medium Pressure (PFA or TFM)
Reaction Vessel Assembly
()
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Sample Preparation Systems
Multiwave
55
PVC rack for holding up to six reaction vessels.
Description Part No. Each
HQ20 B0511540 154
HQ50 or HF50 B0511546 86
MF100 or LF100 B0511546 86
Reaction
Vessel Type Description Part No. Each
HQ20 Rotor Only B0502196 4017
HF50 Rotor Assembly B0511679 7400
(includes Rotor
and 6 vessels)
Reaction Vessel Assembly B0511677 1041
Rotor Only B0502196 4017
HQ50 Rotor Assembly B0502195 8000
(includes Rotor
and 6 vessels)
Reaction Vessel Assembly B0502197 1721
Rotor Only B0502196 4017
MF100 Rotor Assembly B0511537 9800
(includes Rotor
and 6 vessels)
Reaction Vessel Assembly B0511541 1180
Rotor Only B0502196 4017
LF100 Rotor Assembly B3140386 8600
(includes Rotor,
1sensor vessel, and 11
pressure vessles)
Reaction Vessel Assembly* B3140381 1410
Reaction Vessel Assembly** B3140380 545
Rotor Only B3140387 2656
Reaction Vessel Racks
Rotors and Rotor Assemblies
* Sensor Vessel
** Pressure Vessel
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
Sample Preparation Systems
Multiwave 3000
56
The Multiwave 3000
The Anton Paar Multiwave

3000 is a versatile and powerful


microwave sample preparation system for safe high-pressure
acid digestions of all types of organic and inorganic samples.
The Multiwave 3000 provides dramatically improved sample
capacity, a more powerful dual-magnetron design, superior
sensors requiring no cables and built-in methods. It offers
unique pressure monitoring and a multilevel safety system
that give you the performance and safety you want.
Important user benefits of the Multiwave 3000 are:

Reduced analysis times by fast digestion, using rapid


microwave heating and short cool-down times

Superior digestion quality using closed vessels and


simultaneous high pressure and high temperature

Time-saving, easy operation by simplified method


development and easy, intuitive software

Maximum safety provided by easy handling, sophisticated


sensors, and a library of tested methods

1400 W microwave power ensures fast heating

Unpulsed microwave power from 0 to 1400 W


for precise control of critical reactions

Reliable remote sensors for convenient operation

Fast, built-in cooling system to reduce total cycle time


resulting in improved productivity

Intuitive software for easy routine operation


and documentation

Large PTFE-coated cavity for rough laboratory environments

Proven safety system to minimize hazards from


violent reactions

Modular, industrial-type design offers individual


choice of configurations
Multiwave 3000 Accessories
and Supplies
The 16-position rotor maximizes productivity.
Multiwave 3000
Rotor 8 for advanced
digestions offers simultaneous
pressure sensing in all vessels.
Multiwave is a trademark of Anton Paar, GmbH
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Sample Preparation Systems
Multiwave 3000 Digestion Rotors
57
1
2
3
4
5
7
6
8
9
10
11
2
3
4
5
6
7
12
13
11
XQ80
XF100
1
Rotor 8 Consumables and Vessels
Part No. Each
N3142345 960
Part No. Each
N3142346 1310
Pressure Vessel XF100
Complete reaction vessel for various
applications at elevated pressure
and temperature.
Specifications
Volume: 100 mL
Working pressure: 60 bar (870 psi)
Opening pressure: 120 bar (1740 psi)
Max. temperature: 260 C
Components Part No. Each
1 PEEK Protective Cap N3142353 39
2 Safety Disk Holder X N3142350 27
3 Safety Disk X N3142349 11
4 PEK Seal Holder N3142351 141
5 PEEK Center Ring N3142354 25
6 Syringe Connector N3141022 17
7 Venting Screw N3141021 21
8 PTFE-TFM Seal N3141015 72
9 100 mL TFM liner N3141014 130
10 H100 Ceramics Jacket N3141019 388
11 PEEK Protective Casing N3142352 115
Pressure Vessel XQ80
Complete pressure vessel for
digestions at extreme conditions.
Specifications
Volume: 80 mL
Working pressure: 80 bar (1160 psi)
Opening pressure: 120 bar (1740 psi)
Max. temperature: 300 C
Components Part No. Each
1 PEEK Protective Cap N3142353 39
2 Safety Disk Holder X N3142350 27
3 Safety Disk X N3142349 11
4 PEK Seal Holder N3142351 141
5 PEEK Center Ring N3142354 25
6 Syringe Connector N3141022 17
7 Venting Screw N3141021 21
11 PEEK Protective Casing N3142352 115
12 PTFE-TFM Seal XQ N3142348 121
13 Quartz Vessel N3142347 820
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
Sample Preparation Systems
Multiwave 3000 Digestion Rotors
58
Immersing Temperature Probe T-Probe for Rotor 8
Immersing temperature probe
for precise measurement of the
solution temperature in Rotor
8XF100 and XQ80. The sensor
head includes a gas-bulb
thermometer for monitoring
the decomposition
temperature up to 280 C.
The sensor is hermetically
shielded by a sapphire
thermowell. Its microwave-
transparent design does not
interfere with the microwave
field. The installation is very
easy and does not require any
electrical connections, cables
or hoses. Requires Immersion
Tube with either Seal XQ
(N3142410) or Seal XF
(N3142411).
Immersion Tube with Seal XF
Assembly of a special seal holder
with seal for XF100-vessels.
Immersion Tube with Seal XQ
Assembly of a special seal holder
with seal for XQ80-vessels.
Part No. Each
N3142409 2190
Part No. Each
N3142411 980
Rotor 8 Consumables and Vessels
Part No. Each
N3142410 980
1
2
3
4
5
6
7
8
1
2
3
4
5
9
7
8
Immersion Tube
with Seal XF
Immersion Tube
with Seal XQ
Components Part No. Each
1 Safety Disk Holder X N3142350 27
2 Safety Disk X N3142349 11
Syringe Connector N3141022 17
Seal Holder X for T-Probe N3142415 141
Venting Screw N3141021 21
Seal XF* N3141016 92
Husk N3142416 7
Immersion Tube Sapphire X N3142413 653
Seal XQ for T-Probe N3142412 133
1
2
3
4
5
6
7
8
9
* Also used for Rotor 16 Pressure/Temperature Sensor.
()
()
()
()
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Sample Preparation Systems
Multiwave 3000 Digestion Rotors
59
Rotor 8 (without Vessels)
Complete 8 position rotor
without reaction vessels.
Rotor 8 Spare Parts
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
8
9
10
7
Components Part No. Each
1 Rotor 8 Lid N3142364 162
2 Liner Extractor Bolt 8 N3142366 68
Rotor Upper Plate (Assembled) N3142356 5000
Fastening Screw N3142485 99
Thumbwheel N3142363 23
Insulating Bushing* N3142486 18
Bottom Guard N3142357 290
Bottom Load Ring Al Green N3142431 1673
Tension Bar Short N3142430 140
Protection Hose 8 N3142360 13
Part No. Each
N3142355 6700
Rotor 8 for Advanced Digestions
* Used with Black Rotor 8 upper plates shipped prior to July 2005.
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
Sample Preparation Systems
Multiwave 3000 Digestion Rotors
60
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Pressure Vessel MF100 MW3000
Complete reaction vessel for routine
and quality control applications.
Specifications
Volume: 100 mL
Working pressure: 20 bar (290 psi)
Opening pressure: 70 bar (1000 psi)
Max. temperature: 200 C
Pressure Vessel HF100 MW3000
Complete reaction vessel for
versatile applications.
Specifications
Volume: 100 mL
Working pressure: 40 bar (580 psi)
Opening pressure: 70 bar (1000 psi)
Max. temperature: 240 C
Components Part No. Each
1 100 mL TFM Liner N3141014 130
6 M100 PEEK Vessel Jacket N3141018 92
3 PTFE-TFM Seal N3141015 72
5 Safety Disk N3141017 8
8 PEK Screw Cap N3141020 143
7 H100 Ceramics Jacket N3141019 388
9 Venting Screw N3141021 21
Package of 16 Venting Screws N3142452 220
10 Syringe Connector N3141022 17
11 Safety Disk Holder M&H N3141023 25
Pressure/Temperature Sensor Accessory
for Rotor 16
Sensor screw cap for simultaneous
pressure and internal temperature
measurement of one MF or HF vessel.
Pressure Sensor Accessory for Rotor 16
Sensor screw cap for pressure
measurement of one MF or HF vessel.
Components Part No. Each
4 Seal p/T Sensor N3141016 92
12 Immersion Tube Sapphire M&H N3142013 680
13 O-Ring 38x1.5 FPM N3142400 2
14 Seal Holder for p/T Sensor N3142399 153
15 Husk N3142416 7
Husk Assembly Tool N3142456 2
Pressure Vessel MF100
(N3141011) respectively
HF100 (N3141012)
Pressure/Temperature
Sensor Accessory
15
4
13
14
9
10
12
11
5
Pressure Sensor
Accessory
11
3
13
14
9
10
5
11
10
5
8
9
3
1
6 7
Rotor 16 Consumables and Vessels
Part No. Each
N3141011 386
Part No. Each
N3141012 660
Part No. Each
N3141005 3340
Part No. Each
N3142418 2200
()
()
()
()
()
()
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Sample Preparation Systems
Multiwave 3000 Digestion Rotors
61
Rotor 16 (without Vessels)
Complete 16-position rotor without
reaction vessels and sensors.
Components Part No. Each
Rotor 16 Body N3141026 100
Rotor 16 Lid N3141027 72
Rotor 16 Tray N3141028 139
Rotor Base Ring N3141029 158
Vessel Holder N3141030 45
Seal for Vessel Holder N3141031 17
Cheese Head Screw N3142398 2
Liner Extractor Bolt N3141032 68
Rotor 16 Spare Parts
Part No. Each
N3141025 1180
2
1
6
5
3
2
4
1
Spare Parts for the Rotor 16
Rotor 16
7
Rotor 16 for routine digestions
8
1
2
3
4
5
6
7
8
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
Sample Preparation Systems
Multiwave 3000 Drying and Evaporation Rotors
62
1 3
2
4
5
6
7
8
9
10
11
12
13
14
1
4
2
3
Components Part No. Each
Filter Disk Borosilicate Glass N3142000 9
D=30 Porosity 0
Glass Tube N3142001 274
Desiccator Plate N3142002 102
O-Ring N3142003 2
28.24 x 2.62 Silicone
4
3
2
1
Rotor 1 DRY Supplies
Components Part No. Each
Hose Connector 8/8 N3142370 131
Connection Hose N3142367 29
Hose Connector Nut N3142371 80
Syringe Filter N3142374 8
Screw Cap EVAP N3142373 96
Seal EVAP N3142372 66
Vessel Holder N3141030 45
Seal for Vessel Holder N3141031 17
Liner Extractor Bolt 16 N3141032 68
Rotor Tray EVAP N3142369 133
Rotor 16 Body N3141026 100
Rotor Base Ring N3141029 158
Cheese Head Screw N3142398 2
Ring Weight N3142368 39
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Rotor 8 EVAP Supplies
()
()
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Sample Preparation Systems
Multiwave 3000 Solvent Extraction Rotors
63
3
Rotor 8 SOLV Consumables
and Vessels
8
{
1
2
4
3
7
5
6
Pressure/Temperature Sensor Accessory SOLV
Sensor screw cap for simultaneous
pressure and temperature measurement
in Pressure Vessels SOLV100.
Specifications
Temperature range: 0-300 C
Pressure range: 0-86 bar (1250 psi)
Components Part No. Each
Immersion Tube Sapphire M&H N3142013 680
Seal Holder N3142429 153
for p/T Sensor Accessory SOLV
Safety Disk SOLV N3142427 13
Hose Connector SOLV N3142437 36
Screw PEEK N3142436 3
Seal p/T SOLV N3142425 102
Husk N3142416 7
Pressure/Temperature Sensor Adapter
Used to convert Pressure Temperature Accessory
(N3141005) which is used for acid digestion into a sensor
for solvent extraction.
Specifications
Working pressure: 18 bar (252 psi)
Opening pressure: 22 bar (300 psi)
Components Part No. Each
Adapter SOLV N3142420 250
Pressure Vessel SOLV100
Complete reaction vessel for solvent
extraction applications.
Specifications
Working pressure: 18 bar (261 psi)
Opening pressure: 22 bar (319 psi)
Max. temperature: 200
Components Part No. Each
PEEK Screw N3142436 3
Hose Connector N3142437 36
Safety Disk N3142427 13
PEK Screw Cap N3142428 143
Seal SOLV N3142424 82
Liner F100TFM N3141014 130
Vessel Jacket M100 PEEK N3141018 92
7
6
5
4
2
1
8
7
6
5
4
3
2
1
Part No. Each
N3142419 3590
Part No. Each
N3142423 390
2
4
3
7
5
6
1
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
Exhaust Silencer
Seal Forming Device for
8 Caps
Keyboard USA
Quartz Lifting Hook
Quartz Weighing Scoop
Rack 16
Sound Insulator Hood
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
S
a
m
p
l
e

P
r
e
p
a
r
a
t
i
o
n

S
y
s
t
e
m
s
Sample Preparation Systems
Multiwave 3000 Solvent Extraction Rotors and System Spare Parts
64
1
2
3
5
6
7
4
For Rotor XQ80
For Rotor MF100,
HF100, XF100
Seal Forming Device
System Spare Parts
Components Part No. Each
Rotor 16 Lid N3141027 72
Level Indicator N3142438 33
Liner Extractor Bolt 16 N3141032 68
Rotor Tray 8SOLV N3142435 150
Vessel Holder N3141030 45
Seal for Vessel Holder N3141031 17
Rotor 16 Body N3141026 100
7
6
5
4
3
2
1
Part No. Each
N3142453 360
Part No. Each
N3141009 310
Part No. Each
N3141010 170
Part No. Each
N3142451 78
Part No. Each
N3142450 96
Part No. Each
N3142449 98
Part No. Each
N3142454 98
Rotor 8 SOLV Spare Parts
()
()
()
()
()
()
()
()
Whatever your application,
you can depend on PerkinElmer Pure
standards to yield reliable, accurate results.
PerkinElmer offers a wide selection of atomic absorption
calibration standards. Each solution is supplied with a
comprehensive Certificate of Analysis that documents the
quality. To ensure that your measurements are accurate, you
can rely on our certificates to provide complete information.
Quality
PerkinElmer Pure standards are prepared gravimetrically
from high-purity metals and salts, using high-purity reagents.

ASTM Type I, filtered water minimizes cations, anions, and colloids;


resistivity is maintained in the 18-megohm range.

Acids used are the highest purity.

Semi-micro analytical balances and Class A volumetric


glassware are used, and the bottles are subjected to a stringent
leaching/cleaning process.

Following preparation, standards are analyzed for the major element


as well as trace impurities. The results of the analysis are provided
on the Certificate of Analysis.
Reliability
Single-element standards are
measured by three methods:
1. DC arc analysis of starting materials for
trace impurities (semi-quantitative).
2. Gravimetric, wet assay for
major constituents.
3. ICP check of the final solution.
The results of these three
analyses are reported on
the Certificate of Analysis.
NIST or NBS SRMs used for the ICP check
are also reported on the Certificate of Analysis.
Safety
We ship standards to comply with both DOT and
IATA regulations to ensure their safe delivery to you.
Features

ISO 9001 accredited by Underwriters Laboratories including


comprehensive continuous improvement, product recall, corrective action
request, and other quality maintenance and improvement programs

Accreditation by NVLAP/NIST as an EPA performance testing provider

Product labeling meets OSHA and California labeling standards

Bottles are low-density polyethylene from industry standard Nalge


Corporation and are pre-leached and pre-treated for increased product
stability and purity

High-purity acids and ASTM Type I water used in all manufacturing,


as reported on the Certificate of Analysis

Traceability directly to NIST standard reference materials, not independent


sources or secondary NIST SRMs and reported on the Certificate of Analysis

Wet assays on all single-element products via standard, accepted wet


methods and traceable directly to NIST SRM to +/-0.5% of true value
and reported on the Certificate of Analysis

All solutions tested and confirmed for the absence of interfering anions,
e.g. chloride, bromide, etc.

Twelve months guaranteed stability +/-0.5% for all major analytes


for all products PerkinElmer Pure Atomic
Spectroscopy Standards are
manufactured for PerkinElmer
to the highest quality standards.
Standards
PerkinElmer Pure Atomic Spectroscopy Standards
65
Instrument Calibration Standard 1
Matrix/Vol. Concentration of Element Part No. Each
5% HNO
3
/100 mL 5,000 g/mL Calcium N9300218 190
5,000 g/mL Magnesium
5,000 g/mL Potassium
5,000 g/mL Sodium
Instrument Calibration Standard 2
Matrix/Vol. Concentration of Element Part No. Each
5% HNO
3
/100 mL 100 g/mL Chromium N9300219 126
150 g/mL Manganese
400 g/mL Nickel
100 g/mL Silver
200 g/mL Sodium
Instrument Calibration Standard 3
Matrix/Vol. Concentration of Element Part No. Each
5% HNO
3
/100 mL 2,000 g/mL Aluminum N9300220 165
2,000 g/mL Barium
50 g/mL Beryllium
500 g/mL Cobalt
250 g/mL Copper
1,000 g/mL Iron
500 g/mL Vanadium
Instrument Calibration Standard 4
Matrix/Vol. Concentration of Element Part No. Each
5% HNO
3
/100 mL 100 g/mL Arsenic N9300221 114
50 g/mL Cadmium
50 g/mL Lead
50 g/mL Selenium
100 g/mL Titanium
Instrument Calibration Standard 5
Matrix/Vol. Concentration of Element Part No. Each
2% HNO
3
/500 mL 1,000 g/mL Antimony N9300101 101
Instrument Calibration Standard 6
Matrix/Vol. Concentration of Element Part No. Each
10% HNO
3
/500 mL 1,000 g/mL Mercury N9300133 101
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
S
t
a
n
d
a
r
d
s
Standards
PerkinElmer Pure Atomic Absorption Standards
66
Alternate Trace Metal Drinking
Pollution and Wastewater Standards
Alternate Metals I
Alternate Metals II
GFAAS Mixed Standard
Matrix/Vol. Concentration of Element Part No. Each
2% HNO
3
/100 mL 20 g/mL Aluminum N9300214 190
5 g/mL Antimony
5 g/mL Beryllium
10 g/mL Cobalt
10 g/mL Copper
20 g/mL Iron
10 g/mL Manganese
10 g/mL Nickel
5 g/mL Thallium
20 g/mL Vanadium
10 g/mL Zinc
Matrix/Vol. Concentration of Element Part No. Each
2% HNO
3
/100 mL 500 g/mL Calcium N9300215 114
100 g/mL Magnesium
100 g/mL Potassium
500 g/mL Sodium
Matrix/Vol. Concentration of Element Part No. Each
5% HNO
3
100 g/mL Aluminum N9300244 228
w/trace of HF/100 mL 100 g/mL Antimony
100 g/mL Arsenic
50 g/mL Barium
5 g/mL Beryllium
5 g/mL Cadmium
20 g/mL Chromium
50 g/mL Cobalt
50 g/mL Copper
20 g/mL Iron
100 g/mL Lead
20 g/mL Manganese
50 g/mL Nickel
100 g/mL Selenium
10 g/mL Silver
100 g/mL Thallium
CLP Standards
Instrument Calibration Standards
All the solutions you need for daily calibration of your ICP
and HGA

for CLP analyses


Remember to prepare your calibration standards fresh for
each analysis and discard after use
Dilute with high-purity 5% HNO3
()
()
()
()
()
()
()
()
()
S
t
a
n
d
a
r
d
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Standards
PerkinElmer Pure Atomic Absorption Standards
67
Reagents
Groundwater and Wastewater
Pollution Control Check Standards
Trace Metals I
Trace Metals II
Trace Metals III
Matrix/Vol. Concentration of Element Part No. Each
5% HNO
3
/100 mL 500 g/mL Aluminum N9300211 228
100 g/mL Arsenic
100 g/mL Beryllium
25 g/mL Cadmium
100 g/mL Chromium
100 g/mL Cobalt
100 g/mL Copper
100 g/mL Iron
100 g/mL Lead
100 g/mL Manganese
5 g/mL Mercury
100 g/mL Nickel
25 g/mL Selenium
250 g/mL Vanadium
100 g/mL Zinc
Matrix/Vol. Concentration of Element Part No. Each
2% HNO
3
/100 mL 20 g/mL Antimony N9300212 88
10 g/mL Silver
20 g/mL Thallium
Matrix/Vol. Concentration of Element Part No. Each
2% HNO
3
/100 mL 500 g/mL Barium N9300213 152
500 g/mL Calcium
100 g/mL Magnesium
500 g/mL Molybdenum
100 g/mL Potassium
500 g/mL Sodium
Antifoaming Silicone Emulsion B0507226 91
Dow Corning DB 110 A, 500 mL. Controls foaming during
reaction when using the MHS-10, MHS-15, or MHS-20.
Triton X-100 Wetting Agent N9300260 24
Glycerol B3141064 29
Matrix Modifiers for Graphite Furnace AA
High-purity compounds minimize the risk of contamination
Optimum graphite furnace program can be used due to
reduced analyte volatility
Convenient, ready-to-use
Modifier Concentration Volume Part No. Each
Mg(NO
3
)
2
1% Mg (as nitrate) 100 B0190634 71
Pd 10% Pd (as nitrate) 50 B0190635 249
NH
4
H
2
PO
4
10% NH
4
H
2
PO
4
100 N9303445 101
AA Test Mix. Recommended for use in checking sensitivity for eight
elements commonly determined by Flame AA.
Initial Calibration Verification Standard
Matrix/Vol. Concentration of Element Part No. Each
5% HNO
3
/500 mL 200 g/mL Aluminum N9300224 738
60 g/mL Antimony
10 g/mL Arsenic
200 g/mL Barium
5 g/mL Cadmium
500 g/mL Calcium
10 g/mL Chromium
50 g/mL Cobalt
25 g/mL Copper
100 g/mL Iron
3 g/mL Lead
500 g/mL Magnesium
15 g/mL Manganese
40 g/mL Nickel
500 g/mL Potassium
5 g/mL Selenium
10 g/mL Silver
500 g/mL Sodium
10 g/mL Thallium
50 g/mL Vanadium
20 g/mL Zinc
Contract Required Detection Limits (CRDL) Standard
Matrix/Vol. Concentration of Element Part No. Each
2% HCL/100 mL 50 g/mL Calcium 02900540 126
50 g/mL Chromium
50 g/mL Copper
50 g/mL Iron
50 g/mL Nickel
20 g/mL Potassium
10 g/mL Sodium
10 g/mL Zinc
Use as a daily control standard
Check the accuracy and precision of your analysis
Refer to U.S. EPA methods manual 600/4-79-020, Methods for Chemical
Analysis of Water and Wastes: Trace metals I, II, and III methods.
Used for Initial Calibration Verification (ICV). Contains all the elements on
the Inorganic Target Analyte List (TAL) in one solution. Select only those
elements for verification that you will subsequently determine. Dilute
10-fold prior to use for ICP analysis. Dilute 500-fold prior to use for
graphite furnace analysis.
Contract Required Detection Limits
(CRDL) Standard
()
()
()
()
()
()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
S
t
a
n
d
a
r
d
s
Standards
PerkinElmer Pure Atomic Absorption Standards
68
The single-element standards listed have a concentration of 1,000 g/mL in aqueous solution. All
are available in volumes of 500 mL, while selected standards are also available in 100 mL volumes.
Single-Element Calibration Standards
Starting 500 mL 100 mL
Element Symbol Matrix Material Part No. Each Part No. Each
Aluminum Al 2% HNO
3
Al(NO
3
)
3

9H
2
O N9300100 101 N9300184 50
Antimony Sb 2% HNO
3
Sb
2
O
3
N9300101 101 N9300207 50
Arsenic As 2% HNO
3
H
3
AsO
4

12 H
2
0 N9300102 101 N9300180 50
Barium Ba 2% HNO
3
BaCO
3
N9300103 101 N9300181 50
Beryllium Be 2% HNO
3
Be
4
O(C
2
H
3
O
2
)
6
N9300104 101 N9300172 50
Bismuth Bi 10% HNO
3
Bi N9300105 101 N9303761 50
Boron B H
2
O (NH
4
)
2
B
4
O
7

4H
2
O N9300106 101
Cadmium Cd 2% HNO
3
Cd N9300107 101 N9300176 50
Calcium Ca 2% HNO
3
CaCO
3
N9300108 101 N9303763 50
Cerium Ce 2% HNO
3
Ce(NO
3
)
3

6H
2
O N9300110 101
Cesium Cs 2% HNO
3
CsNO
3
N9300111 114
Chromium Cr 2% HNO
3
Cr(NO
3
)
3

9H
2
O N9300112 101 N9300173 50
Cobalt Co 2% HNO
3
CoCO
3
N9300113 101 N9303766 50
Copper Cu 2% HNO
3
Cu N9300114 101 N9300183 50
Dysprosium Dy 2% HNO
3
Dy
2
O
3
N9300115 114
Erbium Er 2% HNO
3
Er
2
O
3
N9300116 114
Europium Eu 2% HNO
3
Eu
2
O
3
N9300117 114
Gadolinium Gd 2% HNO
3
Gd
2
O
3
N9300118 114
Gallium Ga 2% HNO
3
Ga N9300119 114
Germanium Ge H
2
O (NH
4
)
2
Ge(C
2
O
4
)
3

XH
2
O N9300120 114
Gold Au 10% HCl Au N9300121 228 N9303759 126
Hafnium Hf 2% HCl HfOCl
2

8H
2
O N9300122 114 N9303775 50
Holmium Ho 2% HNO
3
Ho
2
O
3
N9300123 114
Indium In 2% HNO
3
In N9300124 114
Iridium Ir 10% HCl IrCl
3

3H
2
O N9300125 228
Iron Fe 2% HNO
3
Fe N9300126 101 N9303771 50
Lanthanum La 2% HNO
3
La
2
O
3
N9300127 101
Lead Pb 2% HNO
3
Pb N9300128 101 N9300175 50
Lithium Li 2% HNO
3
Li
2
CO
3
N9300129 101
Lutetium Lu 2% HNO
3
Lu
2
O
3
N9300130 381
Magnesium Mg 2% HNO
3
Mg N9300131 101 N9300179 50
Manganese Mn 2% HNO
3
Mn(C
2
H
3
O
2
)
3

2H
2
O N9300132 101 N9303783 50
Mercury* Hg 10% HNO
3
Hg N9300133 101 N9300174 50
* Also available at 10 g/mL as Part No. N9300253.
() ()
S
t
a
n
d
a
r
d
s
A
t
o
m
i
c

A
b
s
o
r
p
t
i
o
n
Standards
PerkinElmer Pure Atomic Absorption Standards
69
Starting 500 mL 100 mL
Element Symbol Matrix Material Part No. Each Part No. Each
Molybdenum Mo H
2
O (NH
4
)6Mo
7
O
24

4H
2
O N9300134 101 N9303784 50
Neodymium Nd 2% HNO
3
Nd
2
O
3
N9300135 114
Nickel Ni 2% HNO
3
Ni N9300136 101 N9300177 50
Niobium Nb H
2
O NH
4
NbF6 N9300137 114
Palladium Pd 10% HCl (NH
4
)
2
PdCl
4
N9300138 228 N9303789 126
Phosphorus P H
2
O NH
4
H
2
PO
4
N9300139 101 N9303788 50
Platinum Pt 10% HCl H2PtCl6

XH
2
O N9300140 228
Potassium K 2% HNO
3
KNO
3
N9300141 101 N9303779 50
Praseodymium Pr 2% HNO
3
Pr
6
O
11
N9300142 114
Rhenium Re H
2
O (NH
4
)2ReO
4
N9300143 228
Rhodium Rh 10% HCl RhCl3

3H
2
O N9300144 381
Rubidium Rb 2% HNO
3
RbNO
3
N9300145 101
Ruthenium Ru 10% HCl RuCl
3

3H
2
O N9300146 228
Samarium Sm 2% HNO
3
Sm
2
O
3
N9300147 114
Scandium Sc 2% HNO
3
Sc
2
O
3
N9300148 228
Selenium Se 2% HNO
3
Se N9300149 101 N9300182 50
Silicon Si H
2
O (NH
4
)2SiF
6
N9300150 114 N9303799 50
Silver Ag 2% HNO
3
Ag N9300151 101 N9300171 50
Sodium Na 2% HNO
3
Na
2
CO
3
N9300152 101 N9303785 50
Strontium Sr 2% HNO
3
Sr(NO
3
)
2
N9300153 101
Sulfur S H
2
O (NH
4
)
2
SO
4
N9300154 101
Tantalum Ta H
2
O NH
4
TaF
6
N9300155 114
Tellurium Te 5% HNO
3
Te N9300156 114
Terbium Tb 2% HNO
3
Tb
4
O
7
N9300157 114
Thallium Tl 2% HNO
3
TlNO
3
N9300158 101 N9300170 50
Thulium Tm 2% HNO
3
Tm
2
O
3
N9300160 152
Tin Sn 20% HCl Sn N9300161 152 N9303801 89
Titanium Ti H
2
O (NH
4
)
2
TiF
6
N9300162 114 N9303806 50
Tungsten W H
3
O (NH
4
)
2
WO
4
N9300163 114
Vanadium V 2% HNO
3
NH
4
VO
3
N9300165 101
Ytterbium Yb 2% HNO
3
Yb
2
O
3
N9300166 114
Yttrium Y 2% HNO
3
Y
2
O
3
N9300167 114 N9303810 50
Zinc Zn 2% HNO
3
Zn N9300168 101 N9300178 50
Zirconium Zr 2% HNO
3
ZrO(NO
3
)
2
N9300169 114 N9303812 50
() ()
See page 4 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
See page 2 for ordering information.
For the most current product listing,
visit www.perkinelmer.com/supplies
WinLab32 Software for AA
Software for Atomic Absorption
70
Key Features:

Common look and feel with WinLab32 for ICP for


easy cross-platform use

Flexibility for the most demanding needs

Extensive QC options ensure data quality

Wizards, Multi-language Tool Tips and Tip of


the Day make WinLab32 for AA easy to learn,
easy to use

Data Export allows selected data results to be


transfered to a network computer

Powerful Examine Transient Peaks accelerates


method development

Check sums and Windows

2000 security ensure


integrity for regulatory requirements
Easy to Learn and Use By Design
WinLab32 for AA was not simply
designed by PerkinElmers team of
applications experts, programmers and
graphic designers, it was designed by
laboratory managers and AA users from
around the world. The result is software
that you have to see in operation to fully
appreciate just how easy it is to learn and
use. A few of the highlights that make
WinLab32 easy to learn and use include:

Wizards

Extensive checking

Tip of the Day

Tool Tips

Status panels

Automated shutdown

Analysis List

Context-sensitive Help
Combines Ease of
Use and Flexibility to
Improve Productivity
WinLab32 for AA redefines the software
standard for high-performance atomic
absorption instruments. Designed for
the rigorous needs of todays analytical
laboratory, WinLab32 gives you all the
flexibility and power you need in an easy-
to-use, easy-to-learn package. WinLab32
for AA software provides you with tools and
features needed to quickly start running
samples your way. Only WinLab32 for AA
combines flexibility and ease of use to bring
a new level of productivity to your laboratory.
WinLab32 Software for AA
Data Reprocessing allows you to change parameters
and recalculate results.
A suite of task-oriented windows can be displayed.
WinLab32 Software for AA
Software for Atomic Absorption Analysis
71
Maximize Productivity
In addition to the numerous ease-of-use characteristics,
WinLab32 has the features you need to enhance productivity
in your laboratory.

WinLab32 Offline allows you to create methods, enter sample information,


review or reprocess data all without interrupting the active analysis

Recall Calibration or Initial Calibration Options in the Method Editor


can be used to manually or automatically recall a calibration previously
stored with the method, eliminating the need to reconstruct the curve
prior to sample analysis

Edit Calibration gives you complete control over the quality of your
calibration curve before you proceed with QC and sample analysis

Data Reprocessing allows you to change many method and sample


information parameters after you have collected the data and to recalculate
the results to determine if the changes are appropriate for your samples

Priority Sample and Append to Analysis List allows you to add


samples anytime without interrupting the current analysis
Helping to Meet Regulated Laboratory Requirements
Many laboratories must comply with a variety of regulations
imposed upon them by government agencies or quality
protocols. WinLab32 contains a number of features needed
to help your laboratory meet the regulations, including
21 CFR Part II.
WinLab32 Makes it Easy to Work with Data
Once you have performed analyses, you should be free to
report, change, send, archive, move, or export your data in
any way you wish without following someone elses rigid
protocols. WinLab32 provides a number of tools to help you
work with your data.

Data Reporting Wizard

Data Export Wizard

Archive and restore functions

Maintenance functions
WinLab32 includes a variety of ways to export data,
including parameters such as peak profiles, sample
concentrations, etc.
Worldwide Support
WinLab32 for AA is backed by the largest worldwide
technical support network in the industry just what
you would expect from the leader in analytical
instrumentation for more than 40 years.
Description Part No. Each
WinLab32 Controller Assembly for AA N1010202 4787
Includes computer, 17" flat panel monitor, and
Software Assembly. Contact us for current
models and specifications
WinLab32 Software Assembly for AA N1010200 3059
Includes CD, printer cable, and an IEEE-488
computer interface
WinLab32 Enhanced Security Software Add-on for AA N1010230 3035
Requires WinLab32 Controller or Software Assembly
Wizards make complex tasks easy.
Data Reporting Wizard allows you to report your data
in a variety of formats.
()
www.perkinelmer.com/supplies

Anda mungkin juga menyukai