Anda di halaman 1dari 3

Units Analyst Date Method Result Test

Analytical Report
Sample Number: 141988-001
Date Reported: 8/10/2004
CORE LABORATORIES
CARRERA 39 NO 168-52/56
SANTA FE DE BOGOTA, D.C.
COLUMBIA SOUTH AMERICA,
Date Received: 5/14/2004
Description: Petrotesting
Sample Date:
Sample ID: Santa Rosa 1 Crude
Sample as Received
URIEL SANCHEZ
CORE LABORATORIES
8210 Mosley Rd.
Houston, TX 77075
713 943-9776 Telephone
713 943-3846 Facsimile
Distillation Data
Deg @ 60 F 15.9 DBC 5/20/2004 ASTM D-287 API Gravity
60/60 Deg. F 0.9600 ASTM D-1298 Specific Gravity
mg KOH/g 3.02 CB 5/19/2004 ASTM D-664 Acid Number
WT % 2.2 JT 5/20/2004 ASTM D-6560 Asphaltene
WT % 8.31 JM 5/19/2004 ASTM D-4530 Carbon Residue-Micro
cSt @90F 2152 VS 5/24/2004 ASTM D-445 Kinematic Viscosity
cSt @122 F 518 JM 6/7/2004 ASTM D-445 Kinematic Viscosity
cSt @210 F 42.21 VS 6/1/2004 ASTM D-445 Kinematic Viscosity
cSt @90 f 2113 VS 6/1/2004 ASTM D-445 RCK Kinematic Viscosity
Light Ends Analysis
LV % 0.01 CC ASTM D-5134Mod. Methane
LV % 0.01 Ethane
LV % < 0.01 Propane
LV % < 0.01 Iso-Butane
LV % < 0.01 N-Butane
LV % < 0.01 Neopentane
LV % 0.01 Iso-Pentane
LV % < 0.01 N-Pentane
LV % 0.64 Hexanes
LV % 99.32 Heptanes Plus
Metals By ICP
ppm wt 40 KC 5/20/2004 ASTM D-5708 Nickel
ppm wt 3352 CB 6/9/2004 ASTM D-4629 Nitrogen Total by Chemilum.
Page 1
The analytical results, opinions or interpretations contained in this report are based upon information and material supplied by the client for whose exclusive and confidential use this report has been
made. The analytical results, opinions or interpretations expressed represent the best judgment of Core Laboratories. Core Laboratories, however, makes no warranty or representation, express or
implied, of any type, and expressly disclaims same as to the productivity, proper operations or profitableness of any oil, gas, coal, or other mineral, property, well or sand in connection with which such
report is used or relied upon for any reason whatsoever. This report shall not be reproduced, in whole or in part, without the written approval of Core Laboratories.
Units Analyst Date Method Result Test
Analytical Report
Sample Number: 141988-001
Date Reported: 8/10/2004
CORE LABORATORIES
CARRERA 39 NO 168-52/56
SANTA FE DE BOGOTA, D.C.
COLUMBIA SOUTH AMERICA,
Date Received: 5/14/2004
Description: Petrotesting
Sample Date:
Sample ID: Santa Rosa 1 Crude
Sample as Received
URIEL SANCHEZ
CORE LABORATORIES
8210 Mosley Rd.
Houston, TX 77075
713 943-9776 Telephone
713 943-3846 Facsimile
Deg F +30 JM 5/19/2004 ASTM D-97 Pour Point
lbs/1000bbls 7.9 DRG 8/9/2004 ASTM D-3230 Salt Content
LV % < 0.05 DBC 8/3/2004 ASTM D-4007 Sediment & Water
Simulated Distillation-Crude
Deg F 359 DM 5/19/2004 ASTM D-5307 IBP
Deg F 499 5 % off
Deg F 568 10 % off
Deg F 621 15 % off
Deg F 669 20 % off
Deg F 714 25 % off
Deg F 758 30 % off
Deg F 800 35 % off
Deg F 840 40 % off
Deg F 881 45 % off
Deg F 925 50 % off
Deg F 971 55 % off
Deg F --- 60 % off
Deg F --- 65 % off
Deg F --- 70 % off
Deg F --- 75 % off
Deg F --- 80 % off
Deg F --- 85 % off
Deg F --- 90 % off
Deg F --- 95 % off
@ 1000 Deg. 58.1 % Recovered
@ 1000 Deg. 41.9 % Residue
Page 2
The analytical results, opinions or interpretations contained in this report are based upon information and material supplied by the client for whose exclusive and confidential use this report has been
made. The analytical results, opinions or interpretations expressed represent the best judgment of Core Laboratories. Core Laboratories, however, makes no warranty or representation, express or
implied, of any type, and expressly disclaims same as to the productivity, proper operations or profitableness of any oil, gas, coal, or other mineral, property, well or sand in connection with which such
report is used or relied upon for any reason whatsoever. This report shall not be reproduced, in whole or in part, without the written approval of Core Laboratories.
Units Analyst Date Method Result Test
Analytical Report
Sample Number: 141988-001
Date Reported: 8/10/2004
CORE LABORATORIES
CARRERA 39 NO 168-52/56
SANTA FE DE BOGOTA, D.C.
COLUMBIA SOUTH AMERICA,
Date Received: 5/14/2004
Description: Petrotesting
Sample Date:
Sample ID: Santa Rosa 1 Crude
Sample as Received
URIEL SANCHEZ
CORE LABORATORIES
8210 Mosley Rd.
Houston, TX 77075
713 943-9776 Telephone
713 943-3846 Facsimile
WT % 1.31 CB 5/19/2004 ASTM D-4294 Sulfur, Total by X-Ray Fluoresc.
Metals By ICP
ppm wt 88 KC 5/20/2004 ASTM D-5708 Vanadium
Approved By:
Dan B. Carlson
Laboratory Supervisor
Page 3
The analytical results, opinions or interpretations contained in this report are based upon information and material supplied by the client for whose exclusive and confidential use this report has been
made. The analytical results, opinions or interpretations expressed represent the best judgment of Core Laboratories. Core Laboratories, however, makes no warranty or representation, express or
implied, of any type, and expressly disclaims same as to the productivity, proper operations or profitableness of any oil, gas, coal, or other mineral, property, well or sand in connection with which such
report is used or relied upon for any reason whatsoever. This report shall not be reproduced, in whole or in part, without the written approval of Core Laboratories.