Anda di halaman 1dari 8

Types PSU6n, PSU14n.

Bistable Relay
ABB a global technology leader
Advantage ABB

120 years of technology and innovation

U nparalleled dom ain com petence

G lobal experience

C om plete solution capabilities

Large installed base

Environm ent-friendly technologies


AB B is a global leader in Pow er and Autom ation
technologies that enable utility and industry
custom ers to im prove perform ance w hile low ering
environm ental im pact. The AB B G roup of
com panies operates in around 100 countries and
em ploys over 1,05,000 people.
In India, AB B serves custom ers w ith the com plete
range of pow er and autom ation technologies. The
com pany has a vast installed base, extensive
m anufacturing facilities and a countryw ide m arketing
and service presence.
As a part of its Pow er Technologies offering, ABB
serves electric, gas and w ater utilities as w ell as
industrial and com m ercial custom ers w ith a w ide range
of products, system s and services for pow er
generation, transm ission and distribution. ABBs
system offering ranges from Electrical Balance of Plant
(EBO P) for pow er plants, bulk pow er transm ission,
turnkey substations and com plete electrification to
utility autom ation and pow er distribution.
The product offering covers a w ide spectrum of
technologies across the entire voltage range
including indoor and outdoor circuit breakers, air
and gas insulated sw itchgear, disconnectors,
capacitor banks, reactive pow er com pensators,
pow er transform ers, distribution transform ers,
instrum ent transform ers, C om pact Secondary
Substations (C SS) and R ing M ain U nits (R M U ).
2 AB B
P S U B asic relay
6n w ith 6 free contacts and w ithout indicator
14n w ith 7 or14 free contacts and w ith indicator
2Y m ounted on sheet-m etal base w ith 2 sets of term inal blocks
4Y m ounted on sheet-m etal base w ith 4 sets of term inal blocks
X m ounted on one set of plug-in base
2X m ounted on tw o sets of plug-in base
AB B 3
Features
H igh degree of reliability, even w hen it has
been idle for a long tim e
PSU 14n.. w ith m echanical flag type
indicator
6 / 14 contacts w ith double interruption
C ontact configuration can be changed w ith
ease
D ifferent m ounting variants
W ide range of voltage and contact
configuration
Application
For rem ote and autom atic controls there is often a
need for contactors w hich have tw o stable contact
positions, even in the dead state. This requirem ent
is fulfilled by changeover contactors type PSU ..n..
The application of alternate control pulses to the
coils cause the contacts to change from the one
state to the other. If the supply is interrupted, the
contacts rem ain in their previous position, even
w hen the voltage is restored.
Description
B asically, the PSU changeover contactors are
com posed of the sam e constructional elem ents as
the established contactors type P8n. Tw o m agnet
system s are inter- connected by a pivoted elem ent.
In the type PSU 6n... w ith 6 free contacts, only one
system has contacts; in type PSU 14n... w ith 14 free
contacts, both system s have contacts. In each case
tw o contacts are required for changing over the
connection of the coils.
The contacts are arranged sym m etrically on
both sides of the relay coil and arm ature
assem bly in tw o stacks. They are easily accessible
and the conversion from N /C to N /O contacts
and vice versa is sim ple. The m axim um rated
voltage is 250V D C or AC and the m aterial
used is hard silver.
The follow ing definitions apply for reset and operate
condition:
R eset condition - Arm ature assem bly position is
aw ay from the base i.e. the upper system has been
pulsed and low er system is ready to be pulsed.
The flag strips are invisible i.e. w hite during this
condition. O perate condition - Arm ature assem bly
position is closer to the base i.e. the low er system
has been pulsed and upper system is ready to be
pulsed. The flag strips are visible i.e. red during this
condition.
A transparent, incom bustible cover w ith a gasket
protects the contacts against dirt. The term inals of
the contact stacks them selves perm it tw o w ires of
1.5m m diam eter m axim um to be secured. The
term inals on the base for the external w iring have
holes w ith a diam eter of 3.8m m . The term inals on
the plug-in base can accom m odate tw o w ires, each
w ith a cross-section of 2.5m m
2
.
C hangeover relays m ust alw ays be m ounted w ith
the contact post horizontal, that is w ith the base on
a vertical surface. The plug-in version offers m any
advantages, both from the point of view of
installation and afterw ards for m aintenance. It is
fitted w ith locating pegs w hich prevent it from being
inserted the w rong w ay round. The labelling of the
term inals on the base is identical to that on the
contact stacks.
Type designation of auxiliary relays
Exam ple: PSU 14nX denotes a PSU type relay w ith 7 free contacts, m ounted on one set of plug-in base.
Available types:
Bistable relay types PSU6n, PSU14n
4 AB B
Technical data
Voltage 24V 48V 110V 250V
C ontacts 1 2 in 1 2 in 1 2 in 1 2 in 2 in
Parallel parallel parallel parallel series
D C resistive load 5A 10A 5A 10A 5A 7A 1A - 5A
D C inductive. L/R =15m s 5A 10 A 5 A 8 A 4 A - 1 A - 4 A
D C inductive, L/R =40m s 4 A 8 A 4 A 8 A 3 A - 0.5A - 2 A
AC resistive & inductive 10 A - 10 A - 10 A - 10A - -
Energizing quantities, rated values and limits
R ated voltage U
N
24, 30, 48, 110, 125, 220, 250 V D C
O perative voltage range +10% , -20% of U
N
Perm itted am bient tem perature range 0
o
C to +55
o
C
Pick-up voltage (% U
N
) < 80%
Pick-up tim e at U
N
(typical) 20-40 m sec
M axim um pow er consum ption at the instant of 65 W
sw itching
M echanical durability tested acc to IEC 255 1 x 10
6
sw itching operations, 200 D raw -out / Plug-in
operations
W eight
Type PSU 6n2Y 1.5 K g
Type PSU 6nX 1.3 K g
Type PSU 14nX 2.1 K g
Type PSU 14n2X 2.5 K g
Type PSU 14n4Y 2.4 K g
Contact data
C ontact configuration
Type PSU 14n 7N /O +7N /C , 8N /O +6N /C , 9N /O +5N /C , 10N /O +4N /C ,
11N /O +3N /C , 12N /O +2N /C , 13N /O + 1N /C or 14N O
Type PSU 6n 3N /O +3N /C , 4N /O +2N /C , 5N /O + 1N /C or 6N O
Type PSU 14nX 4N /O +3N /C , 5N /O +2N /C , 6N /O +1N /C , or 7N /O
R ated voltage 250V D C /AC
R ated current 5 A
M ax. m aking current 50 A, 0.5 sec,
M ax. breaking capacities
Electrical endurance; 0.2 m illion operations,
Tested according to IEC 255-23 at 110 V D C , 0.5A L/R 40 m s
Term inals Suitable for 2x2,5m m
2
w ires
Electrical tests
M easurem ent of resistance; tested acc. to IEC 255-6 +/- 10% of specified
Tem perature-rise; tested acc. to IEC 255-6 C oil (class F)
Insulation resistance; tested acc. to IEC 255-5 >100 M O hm at 500 V dc
D ielectric; tested acc. to IEC 255-5 2.0 kV 50 H z, 1 m in
Im pulse; tested acc. to IEC 255-5 5 kV, 1.2/50s, 0.5J
Environmental tests
Vibration response; tested acc. to IEC 255-21-1 10-150H z; 0.5g; 3 axis
Vibration endurance; tested acc. to IEC 255-21-1 10-150H z; 1.0g; 3axis
D ry heat; tested acc. to IEC 68-2-2 at +55
o
C in energized condition
D ry cold; tested acc. to IEC 68-2-1 at 0
o
C
D am p heat (cyclic - 6days); 12 H r/55
o
C + 12 H r/25
o
C x 2 @ 93% R H
Tested acc. to IEC 68-2-30
Storage test; tested acc. to IEC 68-2-48 +70
o
C for 72 H rs and -25
o
C for 72 H rs
AB B 5
Connection diagram and contact configuration
Fig.1- R elay type PSU 14n on sheet-m etal base m ounting or on plug-in base m ounting. The contact
positions are show n for relay in reset condition.
6 AB B
Fig.2- R elay type PSU 14n on plug-in base m ounting. The contact positions are show n for relay in reset condition.
Fig.3- R elay type PSU 6n on sheet-m etal base m ounting or on plug in base m ounting. The contact positions are show n for relay in
reset condition.
Ordering details:
R elay type
Auxiliary voltage
C ontact configuration
AB B 7
Dimensions
Legend
Aa : Term inals
D b : M ounting hole
E01 : C ut-out for rear w iring
* : Space for rem oving hood
Ls : O peration signal
O b : Fixing screw
2) : B ase fixing screw
Ordering details
R efer type designation for selection and m ark ( ) appropriate boxes
Type : P S U 6n2Y Q ty.............. Item no.........
PSU 6nX Q ty.............. Item no.........
Aux Voltage : 24VD C C ontacts 6N /O + 0N /C
30VD C 5N /O + 1N /C
48VD C 4N /O + 2N /C
110VD C 3N /O + 3N /C
125VD C
220VD C
250 VD C
Type : P S U 14nX Q ty.............. Item no.........
Aux Voltage : 24VD C C ontacts 7N /O + 0N /C
30VD C 6N /O + 1N /C
48VD C 5N /O + 2N /C
110VD C 4N /O + 3N /C
125VD C
220VD C
250VD C
Type P S U 14n4Y Q ty.............. Item no.........
P S U 14n2X Q ty.............. Item no.........
Aux Voltage : 24VD C C ontacts 14N /O + 0N /C
30VD C 13N /O + 1N /C
48VD C 12N /O + 2N /C
110VD C 11N /O + 3N /C
125VD C 10N /O + 4N /C
220VD C 9N /O + 5N /C
250VD C 8N /O + 6N /C
7N /O + 7N /C
AB B Lim ited
D istribution Autom ation
M aneja,
Vadodara 390 013, India.
Tel: +91 265 2604384/5/6
+91 265 2604397
Fax:+91 265 2638922
E-m ail: aicds@ in.abb.com
R egional M arketing O ffices:
N o.14, M athura R oad
P.O . Am ar N agar
Faridabad 121 003
Tel: +91 129 2275592,
2279627, 5049000
Fax:+91 129 2279692/5019
4th Floor
N o. 9
Elgin R oad
Kolkata 700 020
Tel: +91 33 22832906/8
Fax:+91 33 22832990
AB B H ouse
D r. S B Path
B allard Estate
M um bai 400 038
Tel: +91 22 56318231 39
Fax:+91 22 56318276/77
Em bassy Star, 1st Floor
N o. 8, Palace R oad
Vasanth N agar
B angalore 560 052
Tel: +91 80 22949779
Fax: +91 80 22949808
C entury Plaza
N o. 3C , 3D & 3F, 3rd Floor
561 / 562, Anna Salai
Teynam pet (M ount R oad)
C hennai 600 018
Tel: +91 44 24340201
Fax:+91 44 24340282
Vandana H ouse
1st Floor
G E R oad, R am kund
R aipur 492 001
Tel: +91 771 5060816-8
Fax:+91 771 5053391 w w w .abb.co.in
N orth
East
W est South
C entral
P
S
U
6
n
/
0
5
/
2
0
0
6
/
0
1
-
1
5
0
0
1
M
D
B
0
8
2
0
4
-
Y
N

0
6
-
2
0
0
6