0 penilaian0% menganggap dokumen ini bermanfaat (0 suara)
241 tayangan8 halaman
The document provides information about ABB's bistable relay types PSU6n and PSU14n. It describes their features such as high reliability, mechanical flag indicators, contact configurations that can be changed easily. It also provides their technical specifications, dimensions, connection diagrams, ordering details and contact configurations.
The document provides information about ABB's bistable relay types PSU6n and PSU14n. It describes their features such as high reliability, mechanical flag indicators, contact configurations that can be changed easily. It also provides their technical specifications, dimensions, connection diagrams, ordering details and contact configurations.
The document provides information about ABB's bistable relay types PSU6n and PSU14n. It describes their features such as high reliability, mechanical flag indicators, contact configurations that can be changed easily. It also provides their technical specifications, dimensions, connection diagrams, ordering details and contact configurations.
Bistable Relay ABB a global technology leader Advantage ABB
120 years of technology and innovation
U nparalleled dom ain com petence
G lobal experience
C om plete solution capabilities
Large installed base
Environm ent-friendly technologies
AB B is a global leader in Pow er and Autom ation technologies that enable utility and industry custom ers to im prove perform ance w hile low ering environm ental im pact. The AB B G roup of com panies operates in around 100 countries and em ploys over 1,05,000 people. In India, AB B serves custom ers w ith the com plete range of pow er and autom ation technologies. The com pany has a vast installed base, extensive m anufacturing facilities and a countryw ide m arketing and service presence. As a part of its Pow er Technologies offering, ABB serves electric, gas and w ater utilities as w ell as industrial and com m ercial custom ers w ith a w ide range of products, system s and services for pow er generation, transm ission and distribution. ABBs system offering ranges from Electrical Balance of Plant (EBO P) for pow er plants, bulk pow er transm ission, turnkey substations and com plete electrification to utility autom ation and pow er distribution. The product offering covers a w ide spectrum of technologies across the entire voltage range including indoor and outdoor circuit breakers, air and gas insulated sw itchgear, disconnectors, capacitor banks, reactive pow er com pensators, pow er transform ers, distribution transform ers, instrum ent transform ers, C om pact Secondary Substations (C SS) and R ing M ain U nits (R M U ). 2 AB B P S U B asic relay 6n w ith 6 free contacts and w ithout indicator 14n w ith 7 or14 free contacts and w ith indicator 2Y m ounted on sheet-m etal base w ith 2 sets of term inal blocks 4Y m ounted on sheet-m etal base w ith 4 sets of term inal blocks X m ounted on one set of plug-in base 2X m ounted on tw o sets of plug-in base AB B 3 Features H igh degree of reliability, even w hen it has been idle for a long tim e PSU 14n.. w ith m echanical flag type indicator 6 / 14 contacts w ith double interruption C ontact configuration can be changed w ith ease D ifferent m ounting variants W ide range of voltage and contact configuration Application For rem ote and autom atic controls there is often a need for contactors w hich have tw o stable contact positions, even in the dead state. This requirem ent is fulfilled by changeover contactors type PSU ..n.. The application of alternate control pulses to the coils cause the contacts to change from the one state to the other. If the supply is interrupted, the contacts rem ain in their previous position, even w hen the voltage is restored. Description B asically, the PSU changeover contactors are com posed of the sam e constructional elem ents as the established contactors type P8n. Tw o m agnet system s are inter- connected by a pivoted elem ent. In the type PSU 6n... w ith 6 free contacts, only one system has contacts; in type PSU 14n... w ith 14 free contacts, both system s have contacts. In each case tw o contacts are required for changing over the connection of the coils. The contacts are arranged sym m etrically on both sides of the relay coil and arm ature assem bly in tw o stacks. They are easily accessible and the conversion from N /C to N /O contacts and vice versa is sim ple. The m axim um rated voltage is 250V D C or AC and the m aterial used is hard silver. The follow ing definitions apply for reset and operate condition: R eset condition - Arm ature assem bly position is aw ay from the base i.e. the upper system has been pulsed and low er system is ready to be pulsed. The flag strips are invisible i.e. w hite during this condition. O perate condition - Arm ature assem bly position is closer to the base i.e. the low er system has been pulsed and upper system is ready to be pulsed. The flag strips are visible i.e. red during this condition. A transparent, incom bustible cover w ith a gasket protects the contacts against dirt. The term inals of the contact stacks them selves perm it tw o w ires of 1.5m m diam eter m axim um to be secured. The term inals on the base for the external w iring have holes w ith a diam eter of 3.8m m . The term inals on the plug-in base can accom m odate tw o w ires, each w ith a cross-section of 2.5m m 2 . C hangeover relays m ust alw ays be m ounted w ith the contact post horizontal, that is w ith the base on a vertical surface. The plug-in version offers m any advantages, both from the point of view of installation and afterw ards for m aintenance. It is fitted w ith locating pegs w hich prevent it from being inserted the w rong w ay round. The labelling of the term inals on the base is identical to that on the contact stacks. Type designation of auxiliary relays Exam ple: PSU 14nX denotes a PSU type relay w ith 7 free contacts, m ounted on one set of plug-in base. Available types: Bistable relay types PSU6n, PSU14n 4 AB B Technical data Voltage 24V 48V 110V 250V C ontacts 1 2 in 1 2 in 1 2 in 1 2 in 2 in Parallel parallel parallel parallel series D C resistive load 5A 10A 5A 10A 5A 7A 1A - 5A D C inductive. L/R =15m s 5A 10 A 5 A 8 A 4 A - 1 A - 4 A D C inductive, L/R =40m s 4 A 8 A 4 A 8 A 3 A - 0.5A - 2 A AC resistive & inductive 10 A - 10 A - 10 A - 10A - - Energizing quantities, rated values and limits R ated voltage U N 24, 30, 48, 110, 125, 220, 250 V D C O perative voltage range +10% , -20% of U N Perm itted am bient tem perature range 0 o C to +55 o C Pick-up voltage (% U N ) < 80% Pick-up tim e at U N (typical) 20-40 m sec M axim um pow er consum ption at the instant of 65 W sw itching M echanical durability tested acc to IEC 255 1 x 10 6 sw itching operations, 200 D raw -out / Plug-in operations W eight Type PSU 6n2Y 1.5 K g Type PSU 6nX 1.3 K g Type PSU 14nX 2.1 K g Type PSU 14n2X 2.5 K g Type PSU 14n4Y 2.4 K g Contact data C ontact configuration Type PSU 14n 7N /O +7N /C , 8N /O +6N /C , 9N /O +5N /C , 10N /O +4N /C , 11N /O +3N /C , 12N /O +2N /C , 13N /O + 1N /C or 14N O Type PSU 6n 3N /O +3N /C , 4N /O +2N /C , 5N /O + 1N /C or 6N O Type PSU 14nX 4N /O +3N /C , 5N /O +2N /C , 6N /O +1N /C , or 7N /O R ated voltage 250V D C /AC R ated current 5 A M ax. m aking current 50 A, 0.5 sec, M ax. breaking capacities Electrical endurance; 0.2 m illion operations, Tested according to IEC 255-23 at 110 V D C , 0.5A L/R 40 m s Term inals Suitable for 2x2,5m m 2 w ires Electrical tests M easurem ent of resistance; tested acc. to IEC 255-6 +/- 10% of specified Tem perature-rise; tested acc. to IEC 255-6 C oil (class F) Insulation resistance; tested acc. to IEC 255-5 >100 M O hm at 500 V dc D ielectric; tested acc. to IEC 255-5 2.0 kV 50 H z, 1 m in Im pulse; tested acc. to IEC 255-5 5 kV, 1.2/50s, 0.5J Environmental tests Vibration response; tested acc. to IEC 255-21-1 10-150H z; 0.5g; 3 axis Vibration endurance; tested acc. to IEC 255-21-1 10-150H z; 1.0g; 3axis D ry heat; tested acc. to IEC 68-2-2 at +55 o C in energized condition D ry cold; tested acc. to IEC 68-2-1 at 0 o C D am p heat (cyclic - 6days); 12 H r/55 o C + 12 H r/25 o C x 2 @ 93% R H Tested acc. to IEC 68-2-30 Storage test; tested acc. to IEC 68-2-48 +70 o C for 72 H rs and -25 o C for 72 H rs AB B 5 Connection diagram and contact configuration Fig.1- R elay type PSU 14n on sheet-m etal base m ounting or on plug-in base m ounting. The contact positions are show n for relay in reset condition. 6 AB B Fig.2- R elay type PSU 14n on plug-in base m ounting. The contact positions are show n for relay in reset condition. Fig.3- R elay type PSU 6n on sheet-m etal base m ounting or on plug in base m ounting. The contact positions are show n for relay in reset condition. Ordering details: R elay type Auxiliary voltage C ontact configuration AB B 7 Dimensions Legend Aa : Term inals D b : M ounting hole E01 : C ut-out for rear w iring * : Space for rem oving hood Ls : O peration signal O b : Fixing screw 2) : B ase fixing screw Ordering details R efer type designation for selection and m ark ( ) appropriate boxes Type : P S U 6n2Y Q ty.............. Item no......... PSU 6nX Q ty.............. Item no......... Aux Voltage : 24VD C C ontacts 6N /O + 0N /C 30VD C 5N /O + 1N /C 48VD C 4N /O + 2N /C 110VD C 3N /O + 3N /C 125VD C 220VD C 250 VD C Type : P S U 14nX Q ty.............. Item no......... Aux Voltage : 24VD C C ontacts 7N /O + 0N /C 30VD C 6N /O + 1N /C 48VD C 5N /O + 2N /C 110VD C 4N /O + 3N /C 125VD C 220VD C 250VD C Type P S U 14n4Y Q ty.............. Item no......... P S U 14n2X Q ty.............. Item no......... Aux Voltage : 24VD C C ontacts 14N /O + 0N /C 30VD C 13N /O + 1N /C 48VD C 12N /O + 2N /C 110VD C 11N /O + 3N /C 125VD C 10N /O + 4N /C 220VD C 9N /O + 5N /C 250VD C 8N /O + 6N /C 7N /O + 7N /C AB B Lim ited D istribution Autom ation M aneja, Vadodara 390 013, India. Tel: +91 265 2604384/5/6 +91 265 2604397 Fax:+91 265 2638922 E-m ail: aicds@ in.abb.com R egional M arketing O ffices: N o.14, M athura R oad P.O . Am ar N agar Faridabad 121 003 Tel: +91 129 2275592, 2279627, 5049000 Fax:+91 129 2279692/5019 4th Floor N o. 9 Elgin R oad Kolkata 700 020 Tel: +91 33 22832906/8 Fax:+91 33 22832990 AB B H ouse D r. S B Path B allard Estate M um bai 400 038 Tel: +91 22 56318231 39 Fax:+91 22 56318276/77 Em bassy Star, 1st Floor N o. 8, Palace R oad Vasanth N agar B angalore 560 052 Tel: +91 80 22949779 Fax: +91 80 22949808 C entury Plaza N o. 3C , 3D & 3F, 3rd Floor 561 / 562, Anna Salai Teynam pet (M ount R oad) C hennai 600 018 Tel: +91 44 24340201 Fax:+91 44 24340282 Vandana H ouse 1st Floor G E R oad, R am kund R aipur 492 001 Tel: +91 771 5060816-8 Fax:+91 771 5053391 w w w .abb.co.in N orth East W est South C entral P S U 6 n / 0 5 / 2 0 0 6 / 0 1 - 1 5 0 0 1 M D B 0 8 2 0 4 - Y N