Cover Page
Tables
Schematic
Machine Views
Component
Connector
Chassis View
Cab View
Engine View
Features
Options
Bookmarks X
EC-C3
EC-C2
E-C60
EC-C1
E-C61
To set your screen resolution do the following:
RIGHT CLICK on the DESKTOP.
Select PROPERTIES.
CLICK the SETTINGS TAB.
MOVE THE SLIDER under SCREEN RESOLUTION
until it shows 1024 X 768.
CLICK OK to apply the resolution.
*This document is best viewed at a
screen resolution of 1024 X 768.
*Due to different monitor sizes and PDF reader preferences
there may be some variance in linked schematic locations
FUNCTION
Zoom In
HOTKEYS (Keyboard Shortcuts)
Zoom Out
Fit to Page
Hand Tool
CTRL / +
KEYS
CTRL / -
CTRL / 0 (zero)
SPACEBAR (hold down)
Find CTRL / F
Pressure
Switch
Temperature
Switch
Level
Switch
Flow
Switch
Circuit Breaker
T
ELECTRICAL SYMBOLS
Spring
(Adjustable)
Variability
Fluid
Conditioner
Pump
or Motor
BASIC HYDRAULIC
COMPONENT SYMBOLS
Click here to save a copy of
this interactive schematic
to your desktop
SCHEMATIC SYMBOLS AND DEFINITIONS
HYDRAULIC SYMBOLS - ELECTRICAL
Transducer
(Fluid)
Transducer
(Gas / Air)
G
Generator Electrical
Wire
Pressure
Switch
M
Electric
Motor
Pressure Switch
(Adjustable)
Temperature
Switch
Pressure
Switch
Temperature
Switch
Level
Switch
Flow
Switch
Circuit Breaker
T
ELECTRICAL SYMBOLS
Spring
Control
Valves
Restriction
Line Restriction
(Fixed)
2-Section
Pump
MAIN AUX.
Spring
(Adjustable)
Variability
Line Restriction
(Variable)
Pressure
Compensation
Pump: Variable and
Pressure Compensated
Hydraulic Pneumatic
Energy Triangles
Fluid
Conditioner
Attachment
Pump
or Motor
BASIC HYDRAULIC
COMPONENT SYMBOLS
Line Restriction
Variable and Pressure
Compensated
Vented Pressurized Return Above Fluid Level Return Below Fluid Level
FLUID STORAGE RESERVOIRS
Pressure Temperature Flow
MEASUREMENT
Unidirectional Bidirectional
ROTATING SHAFTS
One Position Two Position Three Position
Two-way Three-Way Four-Way
ENVELOPES
PORTS
CONTROL
Basic
Symbol
Spring
Loaded
Normal Position
A B
P T
A B
P T
Shifted Position Infinite Position
Shuttle
Pilot
Controlled
VALVES
CHECK
Solenoid
or Manual
Solenoid
and Pilot
Solenoid and
Pilot or Manual
Solenoid
Servo
Thermal Detent
COMBINATION CONTROLS
T
Fuse: A component in an electrical circuit that will open the circuit if too much current flows through it.
Switch (Normally Open): A switch that will close at a specified point (temp, press, etc.). The circle indicates
that the component has screw terminals and a wire can be disconnected from it.
Switch (Normally Closed): A switch that will open at a specified point (temp, press, etc.).
No circle indicates that the wire cannot be disconnected from the component.
Ground (Wired): This indicates that the component is connected to a grounded wire.
The grounded wire is fastened to the machine.

Ground (Case): This indicates that the component does not have a wire connected to ground.
It is grounded by being fastened to the machine.
Reed Switch: A switch whose contacts are controlled by a magnet. A magnet closes the contacts of
a normally open reed switch; it opens the contacts of a normally closed reed switch.
Sender:

A component that is used with a temperature or pressure gauge.
The sender measures the temperature or pressure.
Its resistance changes to give an indication to the gauge of the temperature or pressure.
Relay (Magnetic Switch):

A relay is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close the switch part of the relay.
Solenoid:

A solenoid is an electrical component that is activated by electricity.
It has a coil that makes an electromagnet when current flows through it.
The electromagnet can open or close a valve or move a piece of metal that can do work.
Magnetic Latch Solenoid:

An electrical component that is activated by electricity and held latched by a
permanent magnet. It has two coils (latch and unlatch) that make electromagnet
when current flows through them. It also has an internal switch that places
the latch coil circuit open at the time the coil latches.
BASIC ELECTRICAL COMPONENT SYMBOLS
Push-pull Lever Pedal General Manual Push Button Spring Manual Shutoff
MANUAL CONTROL
External Return Internal Return
Simplified Complete
Internal
Supply Pressure
RELEASED PRESSURE
REMOTE SUPPLY PRESSURE
PILOT CONTROL
Spring Loaded Gas Charged
ACCUMULATORS
Crossing Joining
LINES
Double Acting Single Acting
CYLINDERS
Unidirectional
Bidirectional
FIXED DISPLACEMENT
VARIABLE DISPLACEMENT
NON- COMPENSATED
PUMPS
Unidirectional
Bidirectional
Unidirectional
Bidirectional
FIXED DISPLACEMENT
VARIABLE DISPLACEMENT
NON- COMPENSATED
MOTORS
Unidirectional
Bidirectional
Two
Position
Infinite
Positioning
FLOW IN ONE
DIRECTION
FLOW ALLOWED IN
EITHER DIRECTION
Three
Position
CROSS
FLOW
PARALLEL
FLOW
INTERNAL PASSAGEWAYS
1
2
AG-C4
111-7898
L-C12
3E-5179
9X-1123
Component
Part Number
Pin or Socket Number
Part Number: for
Connector Plug
Harness Identification Letter(s): (A, B, C, AA, AB, AC, ...)
Plug
325-AG135 PK-14
Wire Color
Wire Gauge
Receptacle
1
1
2
2
Sure-Seal connector: Typical representation
of a Sure-Seal connector. The plug and receptacle
contain both pins and sockets.
Deutsch connector: Typical representation
of a Deutsch connector. The plug contains all
sockets and the receptacle contains all pins.
Fuse (5 Amps)
5A
Harness identification code:
This example indicates wire group 325,
wire 135 in harness "AG".
L-C12
3E-5179
Wire, Cable, or Harness Assembly Identification:
Includes Harness Identification Letters and Harness
Connector Serialization Codes (see sample).
Harness Connector Serialization Code: The "C" stands for
"Connector" and the number indicates which connector in the
harness (C1, C2, C3, ...)
HARNESS AND WIRE SYMBOLS
UENR2460-03
July 2013
777F Water Delivery System
Hydraulic System
777F:
JRP1-UP
JXP1-UP
Water Delivery System:
M3J1-UP
Printed in U.S.A. 2014 Caterpillar, All Rights Reserved
COMPONENT TABLE
Component Location
Description
Part
Number
Machin
Locatio
e
n
Schematic
Location
Actuator Gp - Spray Head Control Front (Water) 354-7578 D-1
Actuator Gp - Spray Head Control Rear (Water) 354-7578 C-4, D-4, E-4
Breather As - Hydraulic Tank 9G-5127 C-6
Cannon Gp - Water Actuators E-1
Cooler As - Hydraulic Oil 129-1807 C-6
Filter Gp - Charge 177-6979 D-7
Manifold Gp - Dump Bar Flow Control Rear
354-0304 7 E-4
Manifold Gp - Spray Head Flow Control Front (Pilot) 354-2266 D-1
Manifold Gp - Spray Head Flow Control Rear (Pilot) 354-2266 C-4, D-4, E-4
Manifold Gp - Water Cannon Flow / Position Control 354-0303 E-1
Motor Gp - Water Delivery System 358-0163 D-6
Pump Gp - Charge 177-8924 D-7
Pump Gp - Water 428-7861 13 D-5
Pump Gp - Water Delivery System 435-5902 14 D-8
Tank Gp - Hydraulic Oil 419-0078 15 B-6
Valve Gp - Bypass Cooler 126-0747 C-5
Valve Gp - Charge Cold Relief 198-9219 D-7
Tap
Number
Description
Schematic
Location
7 - D e r u s s e r P p m u P e g r a h C AA
7 - D t r o P g n i l p m a S l i O SOS
Tap Location
Pressure and Sampling
Check Part Numbers in the Parts Manuals for your Specific Machine
422-5872 4
Solenoid As - Pump Control 115-1431
Valve Gp - Relief (Charge) 433-9473
Valve Gp - Relief (Cross Over) 433-9474
1
2
3
5
6
8
9
10
11
12
16
17
U
E
N
R
2
4
6
0
-
0
3
3
0

P
a
g
e
,

(
D
i
m
e
n
s
i
o
n
s
:

3
9

i
n
c
h
e
s

x

2
8

i
n
c
h
e
s
)
Components are shown installed on a fully operable machine with the key and engine off, transmission shifter
in neutral and with parking brake set.
Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations.
SCHEMATIC PART NUMBER: 359-3432, CHANGE: 03, VERSION: -
THIS SCHEMATIC IS FOR THE 777F WATER DELIVERY SYSTEM HYDRAULIC SYSTEM
MEDIA NUMBER: UENR2460-03
Refer to the Parts Manual using a specific serial number prefix in SIS before ordering parts from this schematic.
1 2 3 4 5 6 7 8
A
B
C
D
E
F
1 2 3 4 5 6 7 8
A
B
C
D
E
F
HYDRAULIC CIRCUIT COLOR DESCRIPTIONS
PILOT PUMP OUTPUT
WATER PUMP OUTPUT
CANNON POSITION / FLOW CONTROL
CHARGE PUMP OUTPUT
SUPPLY LINE
WATER DELIVERY PUMP OUTPUT
DRAIN / RETURN LINE
DUMP BAR CONTROL
SPRAY HEAD CONTROL
LINE PATTERNS
Drain / Return Lines
Component Group
Pilot / Load Sensing Pressure
Pressure Line
CALLOUTS
Taps (Pressure, Sampling, Sensor - by letter) YY
(52) VALVE GP - CONTROL
138-1234
Callout Number
(Machine Location from
Component LocationsTable)
Component
Name
Part Number
Connectors (By letter) DL DL D
Tap
Number
Description
Schematic
Location
7 - D e r u s s e r P p m u P e g r a h C A A
7 - D t r o P g n i l p m a S l i O S O S
Tap Location
Pressure and Sampling
S
P
L MS
MP U
T
X
F X
U
A
B
E
X
F
L
RAISE
LOWER
BRAKE
L
O
W
E
R
F
L
O
A
T
S
N
U
B
H
O
L
D
R
A
I S
E
V U
CUSTOMER SUPPLIED
CUSTOMER SUPPLIED
BRAKE COOLING / HOIST TANK
HOIST CONTROL VALVE
REAR MANIFOLD
FRONT MANIFOLD
P T
P T
OUT 1
OUT 2
IN 1 IN 2
G
VALVE GP
VALVE GP
SOLENOID AS
SOS AA
PUMP CONTROL
115-1431
RELIEF (CHARGE)
433-9473
RELIEF (CROSS OVER)
433-9474
428-7861
177-6979
198-9219
177-8924
126-0747
129-1807
358-0163
435-5902
9G-5127
419-0078
422-5872
354-7578
354-0303
354-2266
354-2266
354-0304
354-7578
WATER CANNON
FLOW CONTROL VALVE
DUMP BAR FLOW CONTROL VALVE
COOLING
RELIEF
FLOAT, SNUB
SOLENOID
SOLENOID
(2) ACTUATOR GP
(7) MANIFOLD GP
(9) MANIFOLD GP
(8) MANIFOLD GP
(10) MANIFOLD GP
(1) ACTUATOR GP
(4) CANNON GP
(15) TANK GP
(3) BREATHER AS
(14) PUMP GP
(11) MOTOR GP
(5) COOLER AS
(16) VALVE GP
(12) PUMP GP
(17) VALVE GP
(6) FILTER GP
(13) PUMP GP
WATER
CHARGE
CHARGE
COLD RELIEF
CHARGE
BYPASS (COOLER)
HYDRAULIC OIL
WATER DELIVERY SYSTEM
WATER DELIVERY SYSTEM
HYDRAULIC TANK
HYDRAULIC OIL
WATER ACTUATORS
SPRAY HEAD CONTROL (WATER)
WATER CANNON FLOW/POSITION CONTROL
SPRAY HEAD FLOW CONTROL (PILOT)
SPRAY HEAD FLOW CONTROL (PILOT)
DUMP BAR FLOW CONTROL (REAR)
SPRAY HEAD CONTROL (WATER)
REAR OF WATER TANK
B
VIEW OF AREA B
(HARNESS REMOVED FOR CLARITY)
13
11
9
7
2
2
VIEW ALL CALLOUTS
HYDRAULIC SYSTEM
FUEL TANK
17
16
15
14 12
3
VIEW ALL CALLOUTS
FRONT OF WATER TANK
A
VIEW OF AREA A
(HARNESS REMOVED FOR CLARITY)
LOCATED BEHIND
THE FUEL TANK
SOS
AA
10
8
6
5 4
1
1
VIEW ALL CALLOUTS

Anda mungkin juga menyukai