Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
Pg. 5-7
8
9
10-11
12
13
14-16
17
18-23
24-30
Pg. 31-32
33-35
36-38
39-41
42
43
44
45
Underground Arresters
Product Application
Ratings
Ordering Information
Pg. 46-49
49
50-51
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
riser pole
vault
Underground
Distribution Switchgear
Padmount
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
Underground
Distribution Switchgear
These combined with electronic controls, motor operators and SCADA ready controls make
the building blocks of Elastimold Switchgear.
benefit/description
Feature
EPDM molded rubber construction with stainless
steel hardware and mechanism boxes
Fully sealed
Fully submersible
Maintenance-free
Small footprint
Lightweight
NO gas, NO oil, NO hassle
Deadfront construction
Non-position sensitive
Modular construction
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
Underground
Distribution Switchgear
into a wide arrangement of configurations and applied to solve different system challenges in
the distribution system. Elastimold Switchgear products can be classified in three categories
according to the function they perform:
Switching and Sectionalizing Equipment
Overcurrent Protection Equipment
Automatic Source Transfer Equipment
Padmount
Subsurface / wet or dry vaults
Riser pole
UNDERGROUND DISTRIBUTION SWITCHGEAR APPLICATIONS
Substation 3
NC = normally closed
NO = normally opened
Automatic
Source
Transfer
Substation 1
Critical
Load
Switchgear 3
Switchgear 1
Overcurrent/
Sectionalizing
Substation 2
Sectionalizing Switchgear 2
The switching or manual sectionalizing of loads can be accomplished with the use of Molded
Vacuum Switch (MVS) modules. The simplest manual sectionalizer is a single MVS switch, which
can be installed in a vault, on a pole or inside a padmount enclosure. One of the most popular
applications of this sectionalizer is as a replacement for existing oil fuse cutouts. Two, three and
four-way units are also available in vault and padmount styles. Switches also aid in the manual
reconfiguration of distribution loops by installing them at the open point in the circuit.
Overcurrent protection is accomplished using Molded Canister Fuse (MCAN) or Molded
Vacuum Interrupter (MVI) modules. These can be used in combination with MVS modules.
The simplest product is a single MVI unit, which can be installed in a vault, on a pole or inside
a padmount enclosure. One of the most widely used applications for this configuration is as a
replacement for existing oil fuse cutouts. Two, three and four-way units are also available in any
combination of MVI, MCAN and MVS modules and in vault and padmount styles. Fuses and
interrupters are applied in underground loops to aid in the sectionalizing of the main feeder
and by providing protection to the loads along the loop. For more information on canister fuses,
please refer to the Fuses Product Selection Guide (PG-PC-H).
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
Underground
Distribution Switchgear
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
1. Feeders to sectionalize, so that if there is a fault only a small section of the load
is affected
2. Radial taps deriving from a main feeder or loop, so that a fault on a tap is isolated
from the main circuit
3. Network transformers to isolate the devices in case of overcurrent, excessive
pressure/temperature, etc.
While a switching device contributes to decrease the duration of outages, fault interrupters
contribute to decrease the duration AND frequency of outages (i.e. SAIDI, CAIDI, SAIFI,
CAIFI reliability indices).
AUTOMATIC SECTIONALIZING IMPROVES RELIABILITY
ESP313-BJB-XXX
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
Underground
Distribution Switchgear
B1
S2
Switch 1
Breaker
Locks Out
Switchgear 1
NC = normally closed
NO = normally opened
Switch 2
Switchgear 2
B2
S4
S3
Fault A
B1
S2
OPEN
Switch 1
Breaker
Locks Out
Switchgear 1
CLOSE
Switch 2
Switchgear 2
B2
10
S4
S3
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
COMMON BUS
ASSEMBLY
PADMOUNT
STYLE UNIT
VAULT
STYLE UNIT
MCAN canister
fused tap
Parking stand
Ground rod
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
11
Underground
Distribution Switchgear
Underground
Distribution Switchgear
AT control which receives the output from the voltage sensors and determines if there
is a loss of voltage. If there is a loss of voltage, the AT control sends an OPEN signal to
the preferred source MVS, and a CLOSE signal to the alternate source MVS. When the
voltage is restored, the system transfers back to its normal state, either automatically or
at a set time.
One or two protected taps These can be MCAN or MVI modules, which protect the critical
load against overcurrent. Solid taps are also available.
PADMOUNT AUTOMATIC SOURCE TRANSFER*
MVS Switches
with Motor Operators
AT Control
Voltage
Sensor
*Automatic Source Transfer packages are also available for subsurface/vault installations.
12
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
Distribution Automation
AUTOMATED UNITS
Underground
Distribution Switchgear
Floor Mounted
Vault Installation
Riser Pole
Installation
Improved dispatcher decision-making
and field manpower savings
Automation packages can be added-on
or upgraded as the system requirements
change
Elastimold Modular Switchgear offers the
ability to add automation to existing or new
installations. DC or AC motor operators can be
added to switches or interrupters in vault, riser
pole or padmount installations. The motors are
submersible and the same automation package
can be used in all applications.
The motors can either be operated from a short
distance using a handheld device, as it is the case
in some vault installations, or they can be outfitted
with fully automated controls containing:
Battery
Power supply
Customer-selected RTU
Padmount
Installation
Customer-selected
communications protocol
Customer-selected
communications device
NOTE: Consult your local representative on specific Distribution Automation Packages and configurations available.
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
13
Underground
Distribution Switchgear
LOSS OF REDUNDANCY
the system every time a network transformer is lost. Loss of redundancy indices are
calculated as follows:
Where the number of transformers in the circuit is the number of transformers energized
by the same feeder.
14
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
One substation breaker and one exclusive feeder out to the network
Five transformers are energized by the same feeder
Assume one permanent fault on one transformer in one year
Assume the faulted transformer is de-energized for 6 hours
Because there is only one
breaker for five transformers,
a failure in one transformer
translates in the interruption
of power to 5 transformers for
6 hours.
(6 * 5)
5
5
5
= 6 hours/year
= 1 time/year
Transformer fire
Transformer overheating
Transformer pressure build-up
Overcurrent condition
While the substation breaker may detect most overcurrent faults, faults caused by excessive
pressure/heat or fires cannot be detected by the breaker. One method that allows the automatic
isolation of a network transformer from the primary side, regardless of the type of failure, is
the installation of an MVI fault interrupter on the high side of the transformer. This MVI can
isolate based on overcurrent conditions but also can be wired to isolate the transformer in case
of fire, excessive pressure / heat, emergency signal, etc.
Benefits of such a setup to the network system and the end users include:
The following example calculates the loss of redundancy of the same system used in Example 1,
but adding protection to the primary side of the transformers.
EXAMPLE 2: HIGH-SIDE TRANSFORMER PROTECTION
One substation breaker and one exclusive feeder out to the network
Five transformers are energized by the same feeder
Each transformer is equipped with a fault interrupter installed on the high-side
Assume one permanent fault on one transformer in one year
Assume the transformer is de-energized for 6 hours
A failure in one transformer
Duration of Loss of Redundancy (hours/yr) =
translates in the interruption
of power to only 1 transformer
Frequency of Loss of Redundancy (times/yr) =
for 6 hours.
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
(6 * 1)
5
1
5
= 1.2 hours/year
= 0.2 times/year
15
Underground
Distribution Switchgear
Local /
Remote
Operation
Trip
MVI
EPDM
Molded
Vacuum
Interrupters
MVI
Trip
Transformers
Secondary
Relay
Outputs
Secondary
Relay
Outputs
Network
Protector
Network
Protector
Network
Protector
Fuse
Network
Protector
Fuse
Network
Service Bus
1
Ground 6 /4"
159
mm
Lug
18 1/2"
470 mm
Mounting
42 9/64"
1,070 mm
14"
356 mm
Mounting
5 1/2"
140 mm
120 VAC
Power
Supply
19"
483 mm
Mounting
5 1/2"
140 mm
DOOR IN OPEN
POSITION
MVI
16
Motor
Network Control
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
Product selection
Application
Function
Switching
Sectionalizing
Overcurrent
Protection
PG-PC-E-0907
Product
Page
24
Subsurface/Vault
MVS
Subsurface/Vault
Padmount
Riser Pole
Pole
ESV
ESD/PMVS/
ESP
RMVI
Subsurface/Vault
Source
Transfer
Installation
26
24
NMVI
24
MVI
24
Subsurface/Vault
Padmount
ESV
PMVI/ESD/
ESP
26
Subsurface/Vault
Padmount
ATV/ATS
ATD/ATP
26
15kV
25kV
35kV
600/200A
600/200A
600/200A 12.5/16/20kA
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
17
Underground
Distribution Switchgear
From the following table, select the function and application specific to your system needs.
The last column will indicate the product to be used for the specific selection. With this
information, go to the appropriate section and finalize the construction of the catalog number
that you would need to order.
6 15/64"
176 mm
4 1/16"
103 mm
5 1/2"
140 mm
6 7/16"
164 mm
THREE-Phase Switches
ApproxIMATE Weight 135 lbs.
Open
43
8 5/32"
207 mm
Closed
13 7/16"
341 mm
26"
660 mm
14"
356 mm
8 15/16"
227 mm
5 1/2"
140 mm
23 25/32"
604 mm
12 1/2"
318 mm
5 1/2"
140 mm
5 1/2"
140 mm
6 15/64"
176 mm
/8" / 16 mm Dia. x 7/8" / 22 mm (4) Mounting Holes
Open
43
19"
483 mm
6 1/16"
154 mm
10 5/32"
258 mm
Closed
13 7/16"
341 mm
8 1/32"
204 mm
6 /64"
173 mm
51
25 27/32"
656 mm
9 1/2"
241 mm
19"
483 mm
1 35/64" / 39 mm
18
18 1/2"
470 mm
21"
533 mm
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
RATINGS
27kV
38kV
50/60 Hz
50/60 Hz
50/60 Hz
95kV
125kV
150kV
35kV
60kV
70kV
53kV
78kV
103kV
600 A
600 A
600 A
21 A
21 A
21 A
40 A
40 A
40 A
20,000 A
20,000 A
20,000 A
12,500 A
12,500 A
12,500 A
Continuous Current
600 A
600 A
600 A
900 A
900 A
900 A
Frequency
15.5kV
APPLICATION INFORMATION
Construction: Submersible, corrosion resistant, fully shielded
Ambient Temperature Range: -30 to +40 degrees Celsius
Cable connection
bushings
43
Open
position
Closed
position
Operating
handle
Spring operating
mechanism contained
within 304 stainless steel
housing
Insulated
drive rod
assembly
Vacuum interrupter
contact system
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
19
Underground
Distribution Switchgear
Underground
Distribution Switchgear
30 5/8"
778 mm
Ground
Lug
12 1/2"
318 mm
5 1/2"
140 mm
14 3/32"
358 mm
Mounting
32 7/8"
835 mm
5 1/2"
18 1/2"
140
mm
470 mm
Mounting
5 1/2"
140 mm
19"
483 mm
Mounting
Well Interface
accepts Standard
Bushing Inserts
5 27/32"
148 mm
6 /4"
156 mm
1
8 61/64"
227 mm
9 /2"
241 mm
2 57/64"
73 mm
600 Series
Elbow Interfaces
Closed/
Tripped
Open/
Reset
Locking
Features
8 15/16"
227 mm
20
17 45/64"
450 mm
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
RATINGS
Voltage Class
53kV
600 A
IEEE
C37.74 Standard for
Subsurface, Vault and Padmount
Load Interrupting Switches
21 A
21 A
15.5kV
15.5kV
27kV
35kV
17kV
15.5kV
29kV
38kV
50/60Hz
50/60Hz 50/60Hz
50/60Hz
95kV
95kV
125kV
150kV
35kV
35kV
60kV
70kV
53kV
78kV
103kV
600 A
600 A
600 A
21 A
21 A
40 A
40 A
40 A
40 A
12.5/20 kA
or 16/32 kA
20/
25.6 kA
12.5/
20 kA
12.5/
20 kA
600 A
600 A
600 A
600 A
12.5/20 kA
or 16/32 kA
20/
25.6 kA
12.5/
20 kA
12.5/
20 kA
1000:1
1000:1
1000:1
1000:1
APPLICATION INFORMATION
Meets ANSI C37.60 requirement
Construction: Submersible, corrosion resistant, fully shielded
Ambient Temperature Range: -30 to +40 degrees Celsius
Operating handle
Control module (1)
Sensing module (3)
Positive
contact
position
Spring
operating
mechanism
with tripping
PG-PC-E-0907
Insulated drive
rod assembly
Molded EPDM
rubber insulation
and shielding
Cable connection
bushings
Vacuum fault
interrupter
contact system
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
21
Underground
Distribution Switchgear
Underground
Distribution Switchgear
Molded Vacuum Interrupters are provided with self-powered electronic control packages,
requiring no batteries or external power. Field-selectable Fuse or Relay Curves and Trip
Settings are available. The controls monitor current through the interrupter and, if an
overcurrent condition is detected, send a signal to the vacuum interrupters to trip open and
interrupt the fault. Depending on the application, four electronic control options are available
for the MVI:
INTERNAL CONTROL
22
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
EXTERNAL CONTROL WITH SELECTABLE SINGLE / THREE-PHASE TRIP FUNCTION (80 Control)
Relay Curves (minimum trip 30-600 amp) Fuse Curves (minimum trip 10-200 amp)
Curve #
01
02
03
04
05
06
07
08
09
10
11
12
13
14
16
17
18-23
24-27
28-31
PG-PC-E-0907
Curve Reference #
MVI-TCC-01
MVI-TCC-02
MVI-TCC-03
MVI-TCC-04
MVI-TCC-05
MVI-TCC-06
MVI-TCC-07
MVI-TCC-08
MVI-TCC-09
MVI-TCC-10
MVI-TCC-11
MVI-TCC-12
MVI-TCC-13
MVI-TCC-14
MVI-TCC-16
MVI-TCC-17
MVI-TCC-18 to 23
MVI-TCC-24 to 27
MVI-TCC-28 to 31
Curve Type
E Slow
E Standard
Oil Fuse Cutout
K
Kearney QA
Cooper EF
Cooper NX-C
CO-11-1
CO-11-2
T
CO-9-1
CO-9-2
Cooper 280ARX
F
Kearney KS
GE Relay
CO-8-1 to CO-8-6
CO-9-3 to CO-9-6
CO-11-3 to CO-11-6
Curve #
54
55
56
57
58
59
60
Curve Reference #
MVI-TCC-54
MVI-TCC-55
MVI-TCC-56
MVI-TCC-57
MVI-TCC-58
MVI-TCC-59
MVI-TCC-60
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
Curve Type
E Slow
E Standard
Oil Fuse Cutout
K
Kearney QA
Cooper NX-C
T
23
Underground
Distribution Switchgear
X MV X X - 21 - XX - X X X - SUFFIX
LOAD INTERFACE
SWITCH TYPE
R
N
Blank
Riser Pole
Network
Subsurface
2
6
INTERFACE
E
600 Amp T Body
R Top Interface Rotated 180 Degrees
AB Air Bushings (for Riser Pole Units)
DEVICE
S
I
Switch
Interrupter
LOAD INTERFACE
PHASES
1
3
Single-phase
Three-phase
2
6
Voltage class
15
27
38
15.0kV
27.0kV
38.0kV
External 20 Control with Phase and Ground Trip (to be used on ganged 3-phase MVI mechanism)
External 30 Control with 3-phase Trip Only (to be used on ganged 3-phase MVI mechanism)
External 80 Control with Selectable Single/3-phase Trip Function (to be used on ganged 3-phase MVI mechanism)
External 10 Control with Single Trip Selection (to be used on one 1-phase MVI mechanism)
External 10 Control with Single/3-phase Trip Selection (to be used on three 1-phase MVI mechanisms)
External 20 Control with Phase and Ground Trip (to be used on three 1-phase MVI mechanisms)
External 30 Control with 3-phase Trip Only (to be used on three 1-phase MVI mechanisms)
External 80 Control with Selectable Single/3-phase Trip Function (to be used on three 1-phase MVI mechanisms)
120 VAC Motor Operator and Controller for MVS3 or MV13 Units
12-24 VDC Motor Operator and Controller for MVS3 or MVI3 Units
Parking Stand for MVS or MVI (between bushings for single or 3-phase units)
Parking Stand for MVS3, MVI3 or RMVI3 on Mechanism Cover
Double Parking Stand for MVS3, MVI3 or RMVI3 (between bushings and on mechanism cover)
Bail Tab Plate Installed for 3-phase Units Only
Customer Settings to be Programmed at the Factory
Width
Description
Catalog Number
Height
Depth
Weight
24
6"
6"
6"
6"
6"
152mm
152mm
152mm
152mm
152mm
24"
26"
24"
26"
24"
610mm
660mm
610mm
660mm
610mm
14"
15"
14"
15"
14"
356mm
381mm
356mm
381mm
356mm
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
30lb
30lb
30lb
30lb
30lb
14kg
14kg
14kg
14kg
14kg
PG-PC-E-0907
Width
Description
Catalog Number
Height
Depth
Weight
*
**
MVS3-21-15-XX
21"
533mm 26"
660mm
MVS3-21-27-XX
21"
533mm 26"
660mm
MVS3-21-38-XX
21"
533mm 26"
660mm
Catalog Number
Width
Description
Depth
Height
Weight
30"
RMVI3-21-27-6ABX-YY
30"
RMVI3-21-38-6ABX-YY
30"
RMVI1-21-15-6ABX-3YY
30"
RMVI1-21-27-6ABX-3YY
30"
RMVI1-21-38-6ABX-3YY
30"
SUBSURFACE
Single-Phase Vacuum Interrupter
MVI1-21-15-XX
6"
152mm 31"
787mm
9"
229mm
45lb
20kg
MVI1-21-15-6EX
6"
152mm 31"
787mm
11" 279mm
45lb
20kg
MVI1-21-27-XX
6"
152mm 31"
787mm
9"
229mm
45lb
20kg
MVI1-21-27-6EX
6"
152mm 31"
787mm
11" 279mm
45lb
20kg
MVI1-21-38-XX
6"
152mm 31"
787mm
9"
229mm
45lb
20kg
MVI1-21-38-6EX
6"
152mm 31"
787mm
11" 279mm
45lb
20kg
20"
508mm 31"
787mm
9"
20"
508mm 31"
787mm
9"
MVI1-21-38-XX-3YY
20"
508mm 31"
787mm
9"
MVI3-21-15-XX-YY
20"
508mm 33"
838mm
MVI3-21-27-XX-YY
20"
508mm 33"
838mm
MVI3-21-38-XX-YY
20"
508mm 33"
838mm
Description
Adapter for Connection Between MVI Units with Internal Control, and a Computer for Programming/Viewing Settings
MV1PMB
MV3PMB
MV3HPMB
MV13PMB
35AL-11
Connector Bare Wire Type 3/4" - 16 Rod for Riser Pole Units. Qty. of 1 Needed per Phase
35AL-12
Connector 2-Hole Spade Type 3/4" - 16 Rod for Riser Pole Units. Qty. of 1 Needed per Phase
MVI-TESTER
NOTES:
Weights and dimensions are approximate.
X = 6 for 600 amp or 2 for 200 amp or 6E for 600 amp T interface.
Y = 10, 20, 30, 80 for different electronic controls.
Leave blank for internal (self-contained) control.
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
25
Underground
Distribution Switchgear
XX X X X X - XXXX - XXXX X X
Ways
enclosure material
Switch type
Blank
AT
Auto Transfer
ES
Multi-Way Switch
Mild Steel
Stainless Steel
Type
V
S
D
P
Vault
Sub Surface
Double Side Padmount
Single Side Padmount
interface by way
Single-phase
Three-phase
Voltage class
1
2
3
15.5kV
27.0kV
38.0kV
# Ways
2
3
4
2 Way
3 Way
4 Way
EXAMPLE: ATD324-AAPP-6666
Way 1
Way 2
NOTES:
Custom padmount enclosure dimensions
P
P
are available
Parking stands are standard on padmount units
Consult your local representative on multi-way
configurations that include 38kV MVIs
Way 3 Way 4
Three-phase MVS and MVI are motor ready
Auto transfer ways 1 & 2 are always A
* The Multi-Way Switchgear needs to be de-energized for fuse replacement
26
2
6
COMPONENTS BY WAY
PHASES
54 Inches
E*
F*
G*
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
42"
1,067 mm
Subsurface ESS3X2-TT-66
Underground
Distribution Switchgear
54"
1,372 mm
54"
1,372 mm
vault ESV3X4-TTTT-2222
MVs3 switch
33 /8"
841 mm
1
35 3/8"
899 mm
19"
483 mm
5 1/2"
140 mm
48"
1,219 mm
Stainless steel bottom rails
Catalog Number
Description
ESV313-TTT-XXX
48"
1,219mm
36"
914mm
22"
559mm
750lb
340kg
ESV323-TTT-XXX
48"
1,219mm
36"
914mm
22"
559mm
750lb
340kg
ESV333-TTT-XXX
48"
1,219mm
36"
914mm
22"
559mm
750lb
340kg
ESV314-TTTT-XXXX
48"
1,219mm
36"
914mm
22"
559mm
880lb
399kg
ESV324-TTTT-XXXX
48"
1,219mm
36"
914mm
22"
559mm
880lb
399kg
ESV334-TTTT-XXXX
48"
1,219mm
36"
914mm
22"
559mm
880lb
399kg
PMVS1-21-15-XX
36"
914mm
30"
762mm
30"
762mm
310lb
141kg
PMVS1-21-27-XX
36"
914mm
30"
762mm
30"
762mm
310lb
141kg
PMVS1-21-38-XX
36"
914mm
30"
762mm
30"
762mm
310lb
141kg
ESD312-T-XX
36"
914mm
48"
1,219mm
42" 1,067mm
680lb
308kg
ESD322-T-XX
36"
914mm
48"
1,219mm
42" 1,067mm
680lb
308kg
Width
Depth
Height
Weight
VAULT
PADMOUNT
ESD332-T-XX
36"
914mm
48"
1,219mm
42" 1,067mm
680lb
308kg
ESD313-TTT-XXX
54"
1,317mm
48"
1,219mm
567kg
ESD323-TTT-XXX
54"
1,317mm
48"
1,219mm
567kg
ESD333-TTT-XXX
54"
1,317mm
48"
1,219mm
567kg
ESD314-TTTT-XXXX
54"
1,317mm
48"
1,219mm
626kg
ESD324-TTTT-XXXX
54"
1,317mm
48"
1,219mm
626kg
ESD334-TTTT-XXXX
54"
1,317mm
48"
1,219mm
626kg
NOTE:
Other configurations are available. Consult your local representative on configurations not shown here.
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
27
Width
Description
Depth
Height
Weight
VAULT
ESV312-E-XX
21"
533mm
24"
610mm
11"
279mm
63lb
29kg
ESV322-F-XX
21"
533mm
29"
737mm
11"
279mm
69lb
31kg
ESV332-G-XX
21"
533mm
32"
813mm
11"
279mm
72lb
33kg
ESV312-TE-XX
24"
610mm
36"
914mm
22"
559mm
350lb
159kg
ESV322-TF-XX
24"
610mm
36"
914mm
22"
559mm
350lb
159kg
ESV332-TG-XX
24"
610mm
39"
991mm
22"
559mm
350lb
159kg
ESV313-TEE-XXX
36"
914mm
48"
1,219mm 22"
559mm
560lb
254kg
ESV323-TFF-XXX
36"
914mm
48"
1,219mm 22"
559mm
560lb
254kg
ESV333-TGG-XXX
39"
991mm
48"
1,219mm 22"
559mm
560lb
254kg
ESV313-TTE-XXX
36"
914mm
48"
1,219mm 22"
559mm
560lb
254kg
ESV323-TTF-XXX
36"
914mm
48"
1,219mm 22"
559mm
560lb
254kg
ESV333-TTG-XXX
39"
991mm
48"
1,219mm 22"
559mm
560lb
254kg
ESV313-TPP-XXX
15kV 3-way 3-phase - One Source Switch, Two Vacuum Interrupter Taps
40"
1,016mm
48"
1,219mm 22"
559mm
660lb
299kg
ESV323-TPP-XXX
27kV 3-way 3-phase - One Source Switch, Two Vacuum Interrupter Taps
40"
1,016mm
48"
1,219mm 22"
559mm
660lb
299kg
ESV313-TTP-XXX
15kV 3-way 3-phase - Two Source Switches, One Vacuum Interrupter Tap
40"
1,016mm
48"
1,219mm 22"
559mm
660lb
299kg
ESV323-TTP-XXX
27kV 3-way 3-phase - Two Source Switches, One Vacuum Interrupter Tap
40"
1,016mm
48"
1,219mm 22"
559mm
660lb
299kg
ESV314-TEEE-XXXX
36"
914mm
48"
1,219mm 22"
559mm
670lb
304kg
ESV324-TFFF-XXXX
36"
914mm
48"
1,219mm 22"
559mm
670lb
304kg
ESV334-TGGG-XXXX
36"
914mm
48"
1,219mm 22"
559mm
670lb
304kg
ESV314-TTEE-XXXX
36"
914mm
48"
1,219mm 22"
559mm
740lb
336kg
ESV324-TTFF-XXXX
36"
914mm
48"
1,219mm 22"
559mm
740lb
336kg
ESV334-TTGG-XXXX
39"
991mm
48"
1,219mm 22"
559mm
740lb
336kg
ESV314-TTTE-XXXX
36"
914mm
48"
1,219mm 22"
559mm
810lb
367kg
ESV324-TTTF-XXXX
39"
991mm
48"
1,219mm 22"
559mm
810lb
367kg
ESV334-TTTG-XXXX
39"
991mm
48"
1,219mm 22"
559mm
810lb
367kg
ESV314-TPPP-XXXX
15kV 4-way 3-phase - One Source Switch, Three Vacuum Interrupter Taps
40"
1,016mm
48"
1,219mm 22"
559mm
880lb
399kg
ESV324-TPPP-XXXX
27kV 4-way 3-phase - One Source Switch, Three Vacuum Interrupter Taps
40"
1,016mm
48"
1,219mm 22"
559mm
880lb
399kg
ESV314-TTPP-XXXX
15kV 4-way 3-phase - Two Source Switches, Two Vacuum Interrupter Taps
40"
1,016mm
48"
1,219mm 22"
559mm
880lb
399kg
ESV324-TTPP-XXXX
27kV 4-way 3-phase - Two Source Switches, Two Vacuum Interrupter Taps
40"
1,016mm
48"
1,219mm 22"
559mm
880lb
399kg
ESV314-TTTP-XXXX
15kV 4-way 3-phase - Three Source Switches, One Vacuum Interrupter Tap
40"
1,016mm
48"
1,219mm 22"
559mm
880lb
399kg
ESV324-TTTP-XXXX
27kV 4-way 3-phase - Three Source Switches, One Vacuum Interrupter Tap
40"
1,016mm
48"
1,219mm 22"
559mm
880lb
399kg
PMVI1-21-15-XX
36"
914mm
30"
762mm
30"
762mm
310lb
141kg
PMVI1-21-27-XX
36"
914mm
30"
762mm
30"
762mm
310lb
141kg
PMVI1-21-38-XX
36"
914mm
30"
762mm
30"
762mm
310lb
141kg
PMVI1-21-15-XX-3YY
48"
1,219mm
42"
1,067mm 30"
762mm
680lb
308kg
PMVI1-21-27-XX-3YY
48"
1,219mm
42"
1,067mm 30"
762mm
680lb
308kg
PMVI1-21-38-XX-3YY
48"
1,219mm
42"
1,067mm 30"
762mm
680lb
308kg
ESD312-E-XX
36"
914mm
48"
1,219mm 42"
1,067mm
610lb
277kg
ESD322-F-XX
36"
914mm
48"
1,219mm 42"
1,067mm
610lb
277kg
ESD332-G-XX
36"
914mm
48"
1,219mm 42"
1,067mm
610lb
277kg
PADMOUNT
28
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
Width
Description
Height
Depth
Weight
ESD312-P-XX
36"
914mm
1,067mm
680lb
308kg
ESD322-P-XX
36"
914mm
1,067mm
680lb
308kg
ESD332-P-XX
36"
914mm
1,067mm
680lb
308kg
ESD312-TE-XX
36"
914mm
1,067mm
750lb
340kg
ESD322-TF-XX
36"
914mm
1,067mm
750lb
340kg
ESD332-TG-XX
36"
914mm
1,067mm
750lb
340kg
ESD313-TEE-XXX
1,372mm
1050lb 476kg
ESD323-TFF-XXX
1,372mm
1050lb 476kg
ESD333-TGG-XXX
1,372mm
1050lb 476kg
ESD313-TTE-XXX
1,372mm
1050lb 476kg
ESD323-TTF-XXX
1,372mm
1050lb 476kg
ESD333-TTG-XXX
1,372mm
1050lb 476kg
ESD313-TPP-XXX
15kV 3-way 3-phase - One Source Switch, Two Vacuum Interrupter Taps
1,372mm
1160lb 526kg
ESD323-TPP-XXX
27kV 3-way 3-phase - One Source Switch, Two Vacuum Interrupter Taps
1,372mm
1160lb 526kg
ESD333-TPP-XXX
38kV 3-way 3-phase - One Source Switch, Two Vacuum Interrupter Taps
1,829mm
1500lb 680kg
ESD313-TTP-XXX
15kV 3-way 3-phase - Two Source Switches, One Vacuum Interrupter Tap
1,372mm
1160lb 526kg
ESD323-TTP-XXX
27kV 3-way 3-phase - Two Source Switches, One Vacuum Interrupter Tap
1,372mm
1160lb 526kg
ESD333-TTP-XXX
38kV 3-way 3-phase - Two Source Switches, One Vacuum Interrupter Tap
1,829mm
1500lb 680kg
ESD314-TEEE-XXXX
1,372mm
1170lb 531kg
ESD324-TFFF-XXXX
1,372mm
1170lb 531kg
ESD334-TGGG-XXXX
1,372mm
1170lb 531kg
ESD314-TTEE-XXXX
1,372mm
1240lb 562kg
ESD324-TTFF-XXXX
1,372mm
1240lb 562kg
ESD334-TTGG-XXXX
1,372mm
1240lb 562kg
ESD314-TTTE-XXXX
1,372mm
1310lb 594kg
ESD324-TTTF-XXXX
1,372mm
1310lb 594kg
ESD334-TTTG-XXXX
1,372mm
1310lb 594kg
ESD314-TPPP-XXXX
15kV 4-way 3-phase - One Source Switch, Three Vacuum Interrupter Taps
1,372mm
1380lb 626kg
ESD324-TPPP-XXXX
27kV 4-way 3-phase - One Source Switch, Three Vacuum Interrupter Taps
1,372mm
1380lb 626kg
ESD334-TPPP-XXXX
38kV 4-way 3-phase - One Source Switch, Three Vacuum Interrupter Taps
1,829mm
1500lb 680kg
ESD314-TTPP-XXXX
1,372mm
1380lb 626kg
ESD324-TTPP-XXXX
27kV 4-way 3-phase - Two Source Switches, Two Vacuum Interrupter Taps
1,372mm
1380lb 626kg
ESD334-TTPP-XXXX
38kV 4-way 3-phase - Two Source Switches, Two Vacuum Interrupter Taps
1,829mm
1500lb 680kg
ESD314-TTTP-XXXX
1,372mm
1380lb 626kg
ESD324-TTTP-XXXX
1,372mm
1380lb 626kg
ESD334-TTTP-XXXX
1,829mm
1500lb 680kg
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
29
Underground
Distribution Switchgear
PADMOUNT (continued)
Width
Description
Depth
Height
Weight
**
**
ATS312-AA-XX
21"
533mm
19"
483mm
26"
660mm
60lb
27kg
ATS322-AA-XX
21"
533mm
19"
483mm
26"
660mm
60lb
27kg
ATS313-AAB-XXX
22"
559mm
79"
2,007mm
21"
533mm
300lb
136kg
ATS323-AAB-XXX
22"
559mm
79"
2,007mm
21"
533mm
300lb
136kg
ATS314-AABB-XXXX
22"
559mm
79"
2,007mm
21"
533mm
300lb
136kg
ATS324-AABB-XXXX
22"
559mm
79"
2,007mm
21"
533mm
300lb
136kg
ATS313-AAP-XXX
22"
559mm
79"
2,007mm
21"
533mm
450lb
204kg
ATS323-AAP-XXX
22"
559mm
79"
2,007mm
21"
533mm
450lb
204kg
ATS314-AAPP-XXXX
22"
559mm
79"
2,007mm
21"
533mm
600lb
272kg
ATS324-AAPP-XXXX
22"
559mm
79"
2,007mm
21"
533mm
600lb
272kg
VAULT (All ways mounted onto a common bus and supported by a free-standing frame. For floor mounting.)
ATV313-AAB-XXX
914mm
22"
559mm
620lb
281kg
ATV323-AAB-XXX
914mm
22"
559mm
620lb
281kg
ATV313-AAP-XXX
914mm
22"
559mm
750lb
340kg
ATV323-AAP-XXX
914mm
22"
559mm
750lb
340kg
ATV314-AAPP-XXXX
914mm
22"
559mm
880lb
399kg
ATV324-AAPP-XXXX
914mm
22"
559mm
880lb
399kg
ATD313-AAP-XXX
1,220mm
ATD323-AAP-XXX
1,220mm
ATD314-AAPP-XXXX
1,220mm
ATD324-AAPP-XXXX
1,220mm
PADMOUNT
NOTES:
X=6 for 600 amp or 2 for 200 amp
Other configurations are available. Please consult your local representative on configurations not shown here.
* Dimensions for one switch
** Dimensions for 2-MVS3 interconnected with Multi-Point Junctions. MVIs are mounted elsewhere in the vault.
30
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
Fault Indicators
Thomas & Betts Elastimold Fault Indicators aid
in the location and isolation of the faulted cable
or equipment in overhead and underground
distribution systems through 35kV (L-G). This
product guide details the different types of
faulted circuit indicators, voltage indicators and
phase indicators. With a complete line of elbow
test point mount and cable mount indicators,
you will find the best product to meet your
systems performance needs.
CABLE
FAULT
OPEN
POINT
T1
T
1
T2
T
2
T3
T
3
TT4
4
T5
T
5
T6
T
6
TT7
7
UNFAULTED CIRCUIT
INDICATOR SHOWING
FAULTED CIRCUIT DISPLAY
INDICATOR SHOWING
NORMAL CIRCUIT DISPLAY
benefit/description
Feature
AccQTrip Off the Trip logic circuitry
No need for customer to specify cable O.D. when ordering cable mount FCIs. The
AccQClamp maintains 10% trip accuracy over the entire clamping range (.4"-2.2"),
and is composed of U.V. stable polycarbonate, stainless steel reinforced materials.
Eliminate false resetting and false tripping. Ideal for use on lightly loaded circuits
where sufficient current may not be available to reliably energize a current reset type
fault indicator. Automatic reset upon restoration of system voltage and/or time reset
after four hours.
Voltage operated time reset indicators will not trip or reset due to current backfeed
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
31
Fault Indicators
BLOWN FUSE
AT RISER POLE
Fault Indicators
Overloading Operation
t1 Fault Indicator is connected to the
system and powers up. At 5kV, this takes
3 minutes in the case of the test point
mounted unit and 6 minutes in the case
of the overhead type unit. At higher
voltages the power up time is shorter.
System
Voltage
Primary
Current
Fault
Indicator
Status
Fault
Indicator
Display
Status
System
Voltage
Primary
Current
Fault
Indicator
Status
Fault
Indicator
Display
Status
overloading operation
System
Voltage
Primary
Current
Fault
Indicator
Status
Fault
Indicator
Display
Status
32
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
TPMVF
Model
Fault Indicators
TPMVL/TPMVOL
Model
Basic Operation
A faulted circuit produces an associated
magnetic field which closes a reed switch in
the indicator resulting in a tripped display.
Trip response occurs in .001 seconds allowing
the fault indicator to properly coordinate
with all types of circuit protection schemes
including current-limiting fuses.
To eliminate confusing false trips, voltage
reset indicators are equipped with inrush,
backfeed, overload and cold load pickup
restraint circuitry as standard. Current
sensors are constructed with internal
shielding to prevent inadvertent tripping
when located in close proximity to
adjacent phases, such as junction
mounted applications.
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
33
Fault Indicators
4.16-60kV (L-L)
Nominal Voltage
4.16-60kV (L-L)
1mS
1mS
Fault-Clearing Time1
25kA 10 Cycles 60 Hz
25kA 10 Cycles 60 Hz
Inrush/Backfeed Restraint
None
Power Up Requirement
3 Minutes @ 5kV
None
Display Type
Display Type
Mechanical Flag
Flash Rate
4 Hour Standard
3 Minutes @ 5kV
Reset Time
Power Source
Power Source3
Temperature Range
-40C to +85C
Battery Capacity
2.4 Ah
Housing Material
Weight
258 Grams
15-20 Years
Temperature Range
-40C to +85C
Housing Material
Weight
258 Grams
Nominal Voltage
4.16-60kV (L-L)
Nominal Voltage
4.16-60kV (L-L)
1mS
1mS
Fault-Clearing Time1
25kA 10 Cycles 60 Hz
25kA 10 Cycles 60 Hz
Power Up Requirement
None
Display Type
None
Flash Rate
Power Up Requirement
3 Minutes @ 5kV
Reset Time
Display Type
Power Source
Flash Rate
Battery Capacity
2.4 Ah
4 Hour Standard
3 Minutes @ 5kV
15-20 Years
Power Source3
Temperature Range
-40C to +85C
Battery Capacity
2.4 Ah
Housing Material
15-20 Years
Weight
258 Grams
Temperature Range
-40C to +85C
Housing Material
Weight
258 Grams
NOTES:
1) Prevents false trips due to short time interruptions without loss of voltage.
2) Inrush restraint is standard on voltage reset models. It is not available
on time reset models.
3) Battery powers LED and it is active only when LED is ON. Lithium
Thyonil Chloride batteries provide accurate indication throughout the
entire temperature range.
4) Certified per ANSI/IEEE Standard 495-1986.
34
4 Hour Standard
3
Test Point
Provision
for Hotstick
Installation
and Removal
Test Point
Mounting Provision
Faulted Circuit
Display
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
conductor current
current in k amps
Time in Seconds
cable diameter
Fault Indicators
dimensions
3 7/8"
98 mm
2 1/4"
57 mm
1 1/8" 29 mm
1 /8" 35 mm
3
3 1/4"
83 mm
ORDERING INFORMATION
Catalog prefix
Catalog
Number
Description
Reset Operation
TPMTL
TPMVF
Indicator auto-resets to normal after system voltage restoration. Reset requires 5kV minimum voltage to operate.
Reset operation time is proportional to system voltage.
TPMVL
TPMVOL
Catalog Suffix
Catalog
Number
PG-PC-E-0907
LT
HT
NOTE: For overhead bulk feeder applications, use HIGH or LOW trip ratings (whichever is greater than the minimum
Description
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
35
Fault Indicators
UCMTL
Model
Basic Operation
A faulted circuit produces an associated
magnetic field which closes a reed switch in
the indicator resulting in a tripped display.
Trip response occurs in .001 seconds allowing
the fault indicator to properly coordinate with
all types of circuit protection schemes including
current-limiting fuses.
URD cable mounted fault indicators are
constructed with an internally shielded current
sensor that prevents inadvertent tripping when
located in close proximity to adjacent phases,
such as junction mounted applications.
36
Spring Loaded
Mounting Clamps
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
1mS
25kA 10 Cycles 60 Hz
Display Type
Flash Rate
Reset Time
4 Hour - Standard
Power Source1
Battery Capacity
2.4 Ah
15-20 Years
Temperature Range
-40C to +85C
Housing Material
Weight
258 Grams
Fault Indicators
Nominal Voltage
NOTES:
1) Battery powers LED and it is active only when LED is ON.
Lithium Thyonil Chloride batteries provide accurate indication
throughout the entire temperature range.
2) Certified per ANSI/IEEE Standard 495-1986.
TYPICAL INSTALLATION
As shown below, proper installation of URD cable mounted fault
indicators requires routing cable neutral wires to prevent the ground
return from affecting trip accuracy. Similar procedures should be
followed for tape, wire, LC or other types of shielded cable constructions.
Install Fault Indicator in Area Shown
Fig. 1
* Recommended
Fig. 2
Fig. 3
Fig. 4
INCORRECT
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
37
current in k amps
conductor current
Fault Indicators
Time in Seconds
cable diameter
dimensions
4 1/4"
108 mm
open
2 1/4"
57 mm
3 7/8"
98 mm
1 1/8" 29 mm
1 3/8" 35 mm
2 3/8"
60 mm
open
4 1/4"
108 mm
5 5/8"
143 mm
open
ORDERING INFORMATION
Catalog prefix
Catalog
Number
Description
Reset Operation
UCMTL
Catalog Suffix
Catalog
Number
38
LT
HT
For 600 amp circuits. URD applications, use HIGH trip rating.
NOTE: For overhead bulk feeder applications, use HIGH or LOW trip ratings (whichever is greater than the minimum
Description
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
OLMVF
Model
OLMVL
OLMVOL
Model
PG-PC-E-0907
OLMtL-Lt
Model
Basic Operation
A faulted circuit produces an associated
magnetic field which closes a reed switch
in the indicator resulting in a tripped
display. Trip response occurs in .001
seconds allowing the fault indicator to
properly coordinate with all types of circuit
protection schemes including currentlimiting fuses.
To eliminate confusing false trips, indicators
are equipped with inrush, overload and cold
load pick up restraint circuitry as standard.
Current sensors are constructed with
internal shielding to prevent inadvertent
tripping when located in close proximity
to adjacent phases.
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
39
Fault Indicators
Nominal Voltage
4.16-60kV (L-L)
Nominal Voltage
4.16-60kV (L-L)
1mS
1mS
Fault-Clearing Time1
25kA 10 Cycles 60 Hz
25kA 10 Cycles 60 Hz
Inrush/Backfeed Restraint
None
Power Up Requirement
6 Minutes @ 5kV
None
Display Type
Display Type
Mechanical Flag
Flash Rate
4 Hour Standard
6 Minutes @ 5kV
Reset Time
Power Source
Power Source3
Temperature Range
-40C to +85C
Battery Capacity
2.4 Ah
Housing Material
Weight
258 Grams
15-20 Years
Temperature Range
-40C to +85C
Housing Material
Weight
258 Grams
Nominal Voltage
4.16-60kV (L-L)
Nominal Voltage
4.16-60kV (L-L)
1mS
1mS
25kA 10 Cycles 60 Hz
25kA 10 Cycles 60 Hz
Power Up Requirement
None
Display Type
None
Flash Rate
Power Up Requirement
6 Minutes @ 5kV
Reset Time
4 Hour Standard
Display Type
Power Source3
Flash Rate
Battery Capacity
2.4 Ah
4 Hour Standard
6 Minutes @ 5kV
15-20 Years
Power Source3
Temperature Range
-40C to +85C
Battery Capacity
2.4 Ah
Housing Material
15-20 Years
Weight
258 Grams
Temperature Range
-40C to +85C
Housing Material
Weight
258 Grams
NOTES:
1) Prevents false trips due to short time interruptions without loss of voltage.
2) Inrush restraint is standard on voltage reset models. It is not available
on time reset models.
3) Battery powers LED and it is active only when LED is ON. Lithium
Thyonil Chloride batteries provide accurate indication throughout the
entire temperature range.
4) Certified per ANSI/IEEE Standard 495-1986.
40
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
conductor current
current in k amps
cable diameter
Time in Seconds
Fault Indicators
dimensions
4 1/4"
108 mm
open
2 1/4"
57 mm
3 7/8"
98 mm
1 1/8" 29 mm
1 3/8" 35 mm
2 3/8"
60 mm
open
4 /4"
108 mm
1
5 5/8"
143 mm
open
ORDERING INFORMATION
Catalog prefix
Catalog
Number
Description
Reset Operation
OLMTL
OLMVF
Indicator auto-resets to normal after system voltage restoration. Reset requires 5kV minimum voltage to operate.
Reset operation time is proportional to system voltage.
OLMVL
OLMVOL
Catalog Suffix
Catalog
Number
Description
LT
HT
NOTE: For overhead bulk feeder applications, use HIGH or LOW trip ratings (whichever is greater than the minimum
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
41
Fault Indicators
fo-cable06
FTT
description
catalog number
42
FTT
Field Test Tool, overall dimensions 2" wide x 3" high x 5/8" deep
FO-CABLE06
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
V2
V2 Standard Features
Test Point Mounted Neon Voltage Indicators
provide a convenient, visual method for
determining the energized status of underground
distribution circuits. The indicator consists of a
self-powered voltage sensor connected to a neon
light that flashes when energized. Flash rate
is proportional to the system voltage and the
same indicator may be used for 5kV thru 35kV
applications.
Units are designed to mount directly to 200
& 600 amp elbows, splices and other cable
accessory components equipped with IEEE
386 Standard capacitive test points. Indicators
include a universal mounting provision
allowing installation on test point products as
manufactured by Elastimold and others.
V2
dimensions
3
/8"
10 mm
3 1/4"
83 mm
2"
51 mm
1 3/4"
44 mm
Test Point
Test Point Mounting Provision
Flashing Neon Light
Indicates Energized
Status
V2-TB
20 flash rate
25kV voltage
10kV voltage
40 flash rate
30kV voltage
15kV voltage
70 flash rate
35kV voltage
20kV voltage
PG-PC-E-0907
Basic Operation
1. Mount
the Neon Voltage Indicator to the
test point provision on the test box.
2. Push
and hold the test button to energize
the test point. The green LED light will
flash indicating that battery voltage
is sufficient and that the test box is
operating properly.
3. C
ontinue holding the test button until
the Neon Voltage Indicator begins to
flash. If flashing does not occur after
approximately 30 seconds, then the
Neon Voltage Indicator is defective
and should be discarded.
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
43
Voltage Indicators
Voltage Indicators
Elbow Connectors
with Test Point
Provisions
Non-Metered Probe
Universal End Fitting
Attachment to Hotstick
44
Metered Probe
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
Ordering Information
ORDERING INFORMATION
Catalog
Number
Description
V2
V2TB
PD35
V2
Voltage Indicators
PD-35
V2-TB
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
45
Product Application
Underground Arresters
Voltage surges that exceed the BIL rating of
the distribution system components will cause
damage to the installed equipment. To protect
against these surges, overhead surge arresters
are widely used. Their application is understood
since overhead lines and equipment are directly
affected by voltage surges (e.g. lightning).
However, the use of overhead arresters alone
will not guarantee proper protection
of the insulation in the underground
portion of an electrical distribution system.
The let-through surge from the riser pole
arresters into the underground systems could
be enough to cause damage to the aging
equipment insulation.
Underground Arresters
Elastimold MOV Surge Arresters provide highvoltage lightning and switching surge protection
of transformers, cable, equipment and other
components typically located on underground
power distribution systems. Proper placement,
voltage selection and coordination with riser
pole arresters minimizes damaging surge
voltages by improving protective margins.
Typical applications include installing an
arrester at the end of a radial system or at
both ends of an open point on a loop system.
Additional arresters can be added at strategic
locations upstream from the endpoint for
optimum protection.
benefit/description
Feature
46
Convenient energized connection with other 200 amp loadbreak or deadbreak components
Compact
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
Product Application
installation options
BSA Bushing
Surge Arrester
Bushing
Well
Loadbreak
Bushing Insert
Loadbreak
Feed-Thru Insert
ESA Elbow
Surge Arrester
Underground Arresters
Feed-Thru
Parking
Stand
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PSA Parking
Stand Arrester
47
Product Application
(TYPE 2 TRANSFORMER)
ELBOW ARRESTER
AND PARKING STAND
ARRESTER
OR
OTHER CONFIGURATIONS
Other configurations are possible such as specifying a
bushing arrester on every transformer. This will allow the
open point to be quickly and easily moved to any point in the
circuit while maintaining the surge protection (without moving
all of the portable surge arresters).
48
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
Product Application
RADIAL-FEED CIRCUIT (END POINT )
SINGLE-BUSHING TRANSFORMER
To add surge protection to a single-bushing transformer, utilize a
bushing arrester or an elbow arrester with a feed-thru insert.
TWO-BUSHING TRANSFORMER
To add surge protection to a two-bushing transformer at the end point
of a radial-feed circuit, add an elbow arrester to the unoccupied
bushing or utilize a bushing arrester.
PROTECTIVE CHARACTERISTICS
High Current
Short Duration
Low Current
Long Duration
Duty Cycle
Test
15kV
CLASS
25kV
CLASS
MCOV*
(kVrms)
Duty Cycle
Rating
(kVrms)
2.55
5.1
8.4
10.2
12.7
15.3
8.4
10.2
12.7
15.3
17.0
19.5
22.0
24.4
3
6
10
12
15
18
10
12
15
18
21
24
27
30
3kA
11.0
21.5
32.5
42.5
51.0
60.0
32.5
42.5
51.0
60.0
69.5
83.5
93.0
101.5
5kA
11.5
23.0
34.5
45.0
54.0
64.0
34.5
45.0
54.0
64.0
74.0
89.0
99.0
108.0
10kA
13.0
25.5
38.5
50.0
60.0
71.0
38.5
50.0
60.0
71.0
82.5
99.0
110.0
120.0
20kA
14.5
30.0
43.5
56.5
68.0
80.5
43.5
56.5
68.0
80.5
93.0
112.0
124.5
136.0
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
49
Underground Arresters
RATINGS
Ordering Information
ORDERING INFORMATION
1. D
etermine the appropriate Maximum Continuous Operating Voltage (MCOV) for your
system voltage by using the Elastimold Arrester Application Table.
2. Specify the appropriate Elastimold part number from the Selection Chart.
selection chart
Nominal
2.40
Underground Arresters
15kV
CLASS
25kV
CLASS
4.16
MCOV* kVrms
Solidly
3-Wire
Grounded Ungrounded
Maximum Neutral
Circuits
Circuits
2.54
2.55
2.55
4.40
2.55
Picture
Description
BSA
Bushing
Surge Arrester
(includes
assembly
tool)
5.10
Voltage
Class
Elastimold
Part Number
MCOV
kVrms
15kV
167BSA-3
2.55
15kV
167BSA-6
5.10
15kV
167BSA-10
8.40
15kV
167BSA-12
10.20
15kV
167BSA-15
12.70
15kV
167BSA-18
15.30
25kV
273BSA-10
8.40
25kV
273BSA-12
10.20
25kV
273BSA-15
12.70
25kV
273BSA-18
15.30
25kV
273BSA-21
17.00
Voltage
Class
Elastimold
Part Number
MCOV
kVrms
15kV
167ESA-3
2.55
15kV
167ESA-6
5.10
15kV
167ESA-10
8.40
15kV
167ESA-12
10.20
15kV
167ESA-15
12.70
15.30
4.80
5.08
5.10
5.10
6.90
7.26
5.10
8.40
8.32
8.80
5.10
8.40
12.47
13.20
8.40
15.30
13.20
13.97
8.40
15.30
13.80
14.50
8.40**
15.30
13.80
14.50
10.20
15.30
6.90
7.26
5.10
8.40
8.32
8.80
5.10
8.40
12.47
13.20
8.40
15.30
13.20
13.97
8.40
15.30
13.80
14.50
8.40**
15.30
13.80
14.50
10.20
15.30
20.78
22.00
12.70
20.78
22.00
15.30**
15kV
167ESA-18
25kV
273ESA-10
8.40
25kV
273ESA-12
10.20
25kV
273ESA-15
12.70
25kV
273ESA-18
15.30
23.00
24.34
15.30
24.94
26.40
15.30
24.94
26.40
17.00**
28.00
29.80
17.00
See Notes
1, 2, 3, 4
Picture
Description
ESA
Elbow
Surge Arrester
See Notes
2, 3, 5
25kV
273ESA-21
17.00
Voltage
Class
Elastimold
Part Number
MCOV
kVrms
15kV
167PSA-3
2.55
15kV
167PSA-6
5.10
15kV
167PSA-10
8.40
15kV
167PSA-12
10.20
15kV
167PSA-15
12.70
15.30
50
Picture
Description
PSA
Parking Stand
Arrester
See Notes
1, 2, 3
15kV
167PSA-18
25kV
273PSA-10
8.40
25kV
273PSA-12
10.20
25kV
273PSA-15
12.70
25kV
273PSA-18
15.30
25kV
273PSA-21
17.00
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
PG-PC-E-0907
Ordering Information
ORDERING INFORMATION
selection chart
35kV
CLASS
Nominal
23.00
MCOV* kVrms
34.50
36.51
22.00**
34.50
36.51
24.40
Voltage
Class
Elastimold
Part Number
MCOV
kVrms
BSA
Bushing
Surge Arrester
35kV
375BSA-24
19.50
35kV
375BSA-27
22.00
35kV
375BSA-30
24.40
Description
Voltage
Class
Elastimold
Part Number
MCOV
kVrms
ESA
Elbow
Surge Arrester
35kV
375ESA-24
19.50
35kV
375ESA-27
22.00
35kV
375ESA-30
24.40
Description
Voltage
Class
Elastimold
Part Number
MCOV
kVrms
PSA
Parking Stand
Arrester
35kV
375PSA-24
19.50
35kV
375PSA-27
22.00
35kV
375PSA-30
24.40
See Notes
1, 2, 3, 4
Picture
See Notes
2, 3
Picture
See Notes
1, 2, 3
PG-PC-E-0907
Thomas & Betts Corporation 8155 T&B Boulevard Memphis, TN 38125 800.888.0211 www.tnb.com
51
Underground Arresters
Description
Picture
Solidly
3-Wire
Grounded Ungrounded
Maximum Neutral
Circuits
Circuits
24.34
22.00
PG-PC-E-0907
2007 Thomas & Betts Corporation
All rights reserved. Printed in the USA.