Seccion rectangular
Parametros normales:
Qd =
2.00
[m/s]
hn =
0.77
[m]
b=
2.00
[m]
A=
bhn =
1.54
[m]
P=
b + 2hn =
3.54
[m]
Rh =
A/P =
0.44
[m]
n=
0.01400
[adim]
C=
(Rh)/n =
62.18
[adim]
i=
z/l =
0.001
[adim]
U=
C(Rhi) =
1.30
[m/s]
Q=
UA =
2.00
[m/s]
r=
1/3(hn) =
0.26
[m]
h=
hn + r =
1.03
[m]
En =
hn + U/2g =
0.86
[m]
(Caudal de diseo)
(Tirante normal de agua)
(Coeficiente de Manning)
Parametros criticos:
Qd =
2.00
[m/s]
hc =
0.47
[m]
Bc = b =
2.00
[m]
Ac =
Bchc =
0.94
[m]
Uc =
(gAc/Bc) =
2.15
[m/s]
Q=
UcAc =
2.02
[m/s]
Pc =
Bc + 2hc =
2.94
[m]
Rhc =
Ac/Pc =
0.32
[m]
n=
0.01400
[adim]
ic =
(Ucn)/(Rhc) =
0.00413
[adim]
Ec =
hc + Uc/2g =
0.71
[m]
(Caudal de diseo)
(Coeficiente de Manning)
Tipo de regimen:
Regimen de rio (o subcritico):
Regimen critico:
Fr = 1 ; hn = hc ; U = Uc ; i = ic
Fr =
U/(gA/b) =
0.47
Regimen de rio
Regimen de rio
Regimen de rio
Regimen de rio
[adim]
(Se adopta)
(Se adopta)
^
(Pendiente en el canal)
(Velocidad en el canal)
(Caudal calculado)
(Se adopta)
(Numero de Froude)
Parametros normales:
Qd =
10.00
[m/s]
hn =
1.21
[m]
b=
5.00
[m]
63.43
[]
z=
x : y = tg
2.00
[adim]
B=
b + 2hnz =
9.84
[m]
A=
bhn + hnz =
8.98
[m]
P=
b + 2hn/cos =
10.41
[m]
Rh =
A/P =
0.86
[m]
n=
0.01400
[adim]
C=
(Rh)/n =
69.69
[adim]
i=
z/l =
0.0003
[adim]
U=
C(Rhi) =
1.12
[m/s]
Q=
UA =
10.06
[m/s]
(Caudal de diseo)
(Tirante normal de agua)
(Base del canal)
(Coeficiente de Manning)
r=
1/3(hn) =
0.40
[m]
h=
hn + r =
1.61
[m]
En =
hn + U/2g =
1.27
[m]
Qd =
10.00
[m/s]
(Caudal de diseo)
hc =
0.67
[m]
Bc =
b + 2hcz =
7.68
[m]
Ac =
bhc + hcz =
4.25
[m]
Uc =
(gAc/Bc) =
2.33
[m/s]
Q=
UcAc =
9.89
[m/s]
Pc =
b + 2hc/cos =
8.00
[m]
Rhc =
Ac/Pc =
0.53
[m]
n=
0.01400
[adim]
ic =
(Ucn)/(Rhc) =
0.00247
[adim]
Ec =
hc + Uc/2g =
0.95
[m]
Parametros criticos:
(Coeficiente de Manning)
Tipo de regimen:
Regimen de rio (o subcritico):
Regimen critico:
Fr = 1 ; hn = hc ; U = Uc ; i = ic
Fr =
U/(gA/B) =
0.37
Regimen de rio
Regimen de rio
Regimen de rio
Regimen de rio
[adim]
(Se adopta)
^
(Pendiente en el canal)
(Velocidad en el canal)
(Caudal calculado)
(Se adopta)
(Numero de Froude)
Parametros normales:
Qd =
2.000
[m/s]
hn =
0.78
[m]
45.00
[]
z=
x : y = tg
1.00
[adim]
B=
2hnz =
1.56
[m]
A=
hnz =
0.61
[m]
P=
2hn(1 + z) =
2.21
[m]
Rh =
A/P =
0.28
[m]
n=
0.01300
[adim]
C=
(Rh)/n =
62.06
[adim]
i=
z/l =
0.010
[adim]
U=
C(Rhi) =
3.26
[m/s]
Q=
UA =
1.983
[m/s]
r=
1/3(hn) =
0.26
[m]
(Caudal de diseo)
(Coeficiente de Manning)
h=
hn + r =
1.04
[m]
En =
hn + U/2g =
1.32
[m]
Qd =
2.000
[m/s]
(Caudal de diseo)
hc =
0.96
[m]
Bc =
2hcz =
1.92
[m]
Ac =
hcz =
0.92
[m]
Uc =
(gAc/Bc) =
2.17
[m/s]
Q=
UcAc =
1.999
[m/s]
Pc =
2hc(1 + z) =
2.72
[m]
Rhc =
Ac/Pc =
0.34
[m]
n=
0.01300
[adim]
ic =
(Ucn)/(Rhc) =
0.00336
[adim]
Ec =
hc + Uc/2g =
1.20
[m]
Parametros criticos:
(Coeficiente de Manning)
Tipo de regimen:
Regimen de rio (o subcritico):
Regimen critico:
Fr = 1 ; hn = hc ; U = Uc ; i = ic
Fr =
U/(gA/B) =
1.67
Regimen de torrente
Regimen de torrente
Regimen de torrente
Regimen de torrente
[adim]
(Se adopta)
^
(Pendiente en el canal)
(Velocidad en el canal)
(Caudal calculado)
(Revancha del canal)
(Se adopta)
(Numero de Froude)
Parametros normales:
Qd =
2.00
D=
1.500
hn =
0.55
2arcos(1 - 2hn/D) =
B=
sen(/2)D =
A=
( - sen)D/8 =
P=
D/2 =
Rh =
A/P =
i=
z/l =
n=
0.0130
C=
(Rh)/n =
U=
C(Rhi) =
Q=
UA =
En =
hn + U/2g =
Parametros criticos:
Qd =
2.00
hc =
0.73
2arcos(1 - 2hn/D) =
Bc =
sen(/2)D =
Ac =
( - sen)D/8 =
Uc =
(gAc/Bc) =
Q=
UcAc =
Pc =
D/2 =
Rhc =
Ac/Pc =
n=
0.01300
ic =
(Ucn)/(Rhc) =
Ec =
hc + Uc/2g =
Tipo de regimen:
Regimen de rio (o subcritico):
Regimen critico:
Regimen de torrente (o supercritico):
Fr =
U/(gA/B) =
Condicion por el numero de Froude (F r ):
Condicion por el tirante normal (h n ):
Condicion por la velocidad (U):
Condicion por la pendiente (i):
e en canales
[m/s]
(Caudal de diseo)
[m]
(Diametro de la tuberia)
(Se adopta)
[m]
(Se adopta)
2.59
[]
1.44
[m]
0.58
[m]
1.94
[m]
0.30
[m]
0.010
[adim]
(Pendiente de la tuberia)
[adim]
(Angulo central)
(Ancho superficial normal)
(Area de la tuberia)
(Coeficiente de Manning)
62.91
[adim]
3.44
[m/s]
2.001
[m/s]
(Caudal calculado)
1.15
[m]
[m/s]
[m]
(Caudal de diseo)
(Tirante critico de agua)
(Se adopta)
3.09
[]
1.50
[m]
0.85
[m]
2.36
[m/s]
2.02
[m/s]
2.32
[m]
0.37
[m]
[adim]
(Angulo central)
(Caudal calculado)
(Coeficiente de Manning)
0.00357
[adim]
1.01
[m]
[adim]
(Numero de Froude)
Parametros normales:
Qd =
2.000
[m/s]
hn =
1.40
[m]
B=
1.00
[m]
A=
2Bhn/3 =
0.93
[m]
P=
B + (8hn)/3B =
6.23
[m]
Rh =
A/P =
0.15
[m]
n=
0.01300
[adim]
C=
(Rh)/n =
56.06
[adim]
i=
z/l =
0.010
[adim]
U=
C(Rhi) =
2.17
[m/s]
Q=
UA =
2.026
[m/s]
r=
1/3(hn) =
0.47
[m]
h=
hn + r =
1.87
[m]
En =
hn + U/2g =
1.64
[m]
(Caudal de diseo)
(Coeficiente de Manning)
Parametros criticos:
Qd =
2.000
[m/s]
hc =
1.12
[m]
Bc = B
1.00
[m]
Ac =
2Bhc/3 =
0.75
[m]
Uc =
(gAc/Bc) =
2.71
[m/s]
Q=
UcAc =
2.020
[m/s]
Pc =
Bc + (8hc)/3Bc =
4.35
[m]
Rhc =
Ac/Pc =
0.17
[m]
n=
0.01300
[adim]
ic =
(Ucn)/(Rhc) =
0.013
[adim]
Ec =
hc + Uc/2g =
1.49
[m]
(Caudal de diseo)
(Coeficiente de Manning)
Tipo de regimen:
Regimen de rio (o subcritico):
Regimen critico:
Fr = 1 ; hn = hc ; U = Uc ; i = ic
Fr =
U/(gA/B) =
0.72
Regimen de rio
Regimen de rio
Regimen de rio
Regimen de rio
[adim]
(Se adopta)
(Se adopta)
(Pendiente en el canal)
(Velocidad en el canal)
(Caudal calculado)
^
(Se itera con hn hasta que Q sea aprox = a Qd)
(Se adopta)
(Numero de Froude)