Immunomonitoring of T cell based immune responses spans a wide field of therapeutic applications such as
infectious and autoimmune diseases and is particularly important for vaccine research. Regardless of the
therapeutic application, immunomonitoring can be a daunting task due to the variability of methods and protocols
available. There are several commonly used functional assays for the enumeration of antigen specific CD8 + T cells
and there is great variability in the protocols that are used for these assays. Thus, making it increasing difficult to
thoroughly interpret data obtained from multi-center clinical trials and to compare results between laboratories. In
order to address some of the issues associated with immunomonitoring of clinical trials, the Association for
Immunotherapy of Cancer (CIMT) formed a CIMT monitoring panel tasked to standardize protocols for assaying T
Subscribe to PBMC
Basics
cell antigen immune responses. Thirteen centers from 6 different European countries participated in this study. They
were given the same samples and asked to determine the number of antigen specific T cells and assess their
Your email:
antigen specific function using tetramer staining and a functional assay of their choice. Common techniques used
for monitoring antigen induced immune responses included ELISPOT assays, HLA-multimer staining and
Subscribe
Latest Posts
Positive Selection vs Negative
Selection for Cell Isolation
Optimizing Assays to Find Rare
Antigen-Specific T cells in
Tetramer results from the Phase I study showed the number CD8 + cells analyzed significantly affected the
sensitivity of tetramer staining. Antigen-specific T cell reactivity when less than 30,000 CD8 + T cells were
counted resulted in only 70% responsiveness detected. In contrast, when more than 30,000 CD8 + cells were
counted, an 89% response was observed.Although, when antigen-specific T cells were present at high frequencies
the number of counted cells did not matter. Interestingly, Ab clone variability, Ab concentration, or cytometer type
did not result in any significant differences. Thus, the main factors affecting antigen-specific T cell reactivity by
tetramer staining is the number of CD8 + cells used. For Phase II it was then recommended at least 1 x106 PBMCs
are used for this assay.
Browse by Tag
The majority of groups chose the INF- ELISPOTas their functional assay. Results showed a
large amount of heterogeneity between the centers. Some centers included a resting phase
after thawing the cells, of 2-20 hours, resulting in 73% positive reactivity (number of spot
antibody (3)
forming cells per seeded PBMC). In contrast, not allowing a resting phase resulted in only
detecting 30% of the positive cells. Additionally, intra-center replicate reproducibility was
arthritis (1)
significantly affected by the number of replicates used, where duplicates often failed the
Autoantibodies (1)
Student t test and triplicates were sufficient to reach statistical significance. Addition of allogenic-APCs for binging
Autoimmunity (3)
and presentation of the synthetic peptides was found to have a negative effect on detection response (28% of all
biobank (1)
responses vs. 58%). When looking at the number of cells seeded per well, those with more than 4 x105 PBMC
detected 71% positive samples and those with less than 4 x105 only detected 43%. Granted, when antigen specific
Cancer (2)
T cells were available at high frequencies the number of counted cells did not affect the response rates.
Consequently, Phase IIs minimum requirements for the INF- ELISPOT protocol included: (1) triplicates should
be performed for each test antigen (2) avoid using allogenic-APCs (3) include a resting phase (4) use over 4 x 10 5
PBMCs per well.
Another interesting finding from this study was that lab experience in performing these assays had no effect on the
performance of the assays compared to labs that had just adopted the techniques. Further highlighting the
importance of developing standardized protocols for immunomonitoring assays. This study did not however,
Chemotherapy (1)
address specific detection limits for the ELISPOT assays, the variability between ELISPOT plate readers, nor
serum source effects on background and specificity. In addition, it was not reported whether live/dead cell stains
where included in the tetramer assays and how combinations of these may have had an effect on the sensitivity of
the assay.
Overall, this study identified several factors that should be generally implemented when performing tetramer
IgM (1)
staining and INF- ELISPOT assays with cryopreserved PBMC samples. Furthermore, these protocol modifications
are particularly important when assaying antigen-specific T cell populations present at low frequencies.
Immunology (4)
Immunology Research Methods
(7)
immunotherapy (1)
INF ELISPOT (1)
Reference:
MFI (1)
The CIMT-monitoring panel: a two-step approach to harmonize the enumeration of antigen-specific CD8+ T
lymphocytes by structural and functional assays. Britten CM, Gouttefangeas C, Welters MJ, Pawelec G, Koch S,
NK cell (2)
oncology (2)
Straten P, Schmitt M, Giannopoulos K, Maier R, Veelken H, Bertinetti C, Konur A, Huber C, Stevanovi S, Wlfel T,
PBMC (28)
van der Burg SH. Cancer Immunol Immunother. 2008 Mar;57(3):289-302. Epub 2007 Aug 25.
Jemima Escamilla is a senior Ph.D candidate in Molecular and Medical Pharmacology at the UCLA
David Geffen School of Medicine. Her research focus integrates hormonally regulated cancer
progression and cancer immunology.
Tags:CD8+ cell, Flow Cytometry, jemima escamilla, immunotherapy, Cell-based therapies, INF ELISPOT
Comments
Thank you for sharing this information. This is very useful.
Posted @ Saturday, June 01, 2013 11:49 AM by Jacky Woo
Post Comment
Name
*
Email
*
Website (optional)
Comment
*
Allowed tags: <a> link, <b> bold, <i> italics
Receive email when someone replies.
Subscribe to this blog by email.
Post Comment
Advanced Search
Partner
Resources
TGA Sciences
SV Bio
NextGen Sciences
UCLA Clinical &
Translational Lab
BioBlog
Donate
Contact Us
PBMC Basics
Technical /
Protocols
Immunology
Regenerative
Medicine
Neurology
Oncology
Our Mission
How it Works
Become a Donor
310.436.9441
Sanguine Biosciences
28903 Avenue Paine
Valencia, CA 91355
info@sanguinebio.com
fax: 310-893-6763