CECW-CE

DEPARTMENT OF THE ARMY


U.S. Army Corps of Engineers
Washington, DC 20314-1000

EM 1110-2-2704

Manual
No. 1110-2-2704

12 July 2004

Engineering and Design


CATHODIC PROTECTION SYSTEMS FOR CIVIL WORKS STRUCTURES
Table of Contents
Subject

Paragraph

Page

Chapter 1
Introduction
Purpose and Scope ........................................................................................................... 1-1
Applicability .................................................................................................................... 1-2
References........................................................................................................................ 1-3
Background ...................................................................................................................... 1-4

1-1
1-1
1-1
1-2

Chapter 2
Corrosion Mitigation Plan
Corrosion Protection Coordinator.................................................................................... 2-1
Plan .................................................................................................................................. 2-2
Tests and Adjustments ..................................................................................................... 2-3

2-1
2-1
2-2

Chapter 3
Expert Assistance
Background ...................................................................................................................... 3-1
Expertise Required........................................................................................................... 3-2
Types of Assistance Available......................................................................................... 3-3
Element Responsibility .................................................................................................... 3-4

3-1
3-1
3-1
3-1

Chapter 4
Testing and Optimizing
Equipment and Personnel ................................................................................................ 4-1
Optimizing System........................................................................................................... 4-2

4-1
4-1

Chapter 5
System Selection
Corrosion Protection ........................................................................................................ 5-1
Types of CPSs.................................................................................................................. 5-2
CPS Selection................................................................................................................... 5-3

5-1
5-1
5-1

Chapter 6
System Design, Construction, Operation, Maintenance, and Restoration
Design .............................................................................................................................. 6-1
Construction..................................................................................................................... 6-2
Operation and Maintenance ............................................................................................. 6-3

6-1
6-2
6-2
i

More ebooks : http://artikel-software.com/blog

Restoration ....................................................................................................................... 6-4

6-3

Chapter 7
Training and Services
Training............................................................................................................................ 7-1
Services ............................................................................................................................ 7-2

7-1
7-1

Appendix A
Sample Corrosion Mitigation Plan
Appendix B
Detailed Cathodic Protection Design Procedures for
Pike Island Auxiliary Lock Gates
Appendix C
Sacrificial Cathodic Protection System Basic Design Formulae and
Reference Tables for Civil Works Applications
Appendix D
Detailed Galvanic Cathodic Protection Design Example Based on
Pike Island Auxiliary Lock Gates Using Slab Anodes
Appendix E
Detailed Galvanic Cathodic Protection Design Example Based on
Pike Island Auxiliary Lock Gates Using Rod And Bar Anodes
Appendix F
Detailed Galvanic Cathodic Protection Design Example Based on
Longview Lake Intake Tower Emergency Drawdown Gate Leaf

ii

More ebooks : http://artikel-software.com/blog

Free Download / Subscription Industrial and Engineering Magazines


http://magz.tradepub.com

or get directly on individual magazine below :

More free magazines ...

More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
CHAPTER 1
INTRODUCTION
1-1. Purpose and Scope. This manual provides guidance for the selection, design, installation,
operation, and maintenance of cathodic protection systems (CPSs) used to supplement paint
systems for corrosion control on civil works hydraulic structures. It also discusses possible
solutions to some of the problems with CPSs that may be encountered at existing projects.
1-2. Applicability. This manual applies to all USACE Commands having civil works
responsibilities.
1-3. References.
a. MIL-HDBK-1004/10, Electrical Engineering Cathodic Protection.
b. EM 1110-2-3400, Painting: New Construction and Maintenance.
c. ETL 1110-9-10, Cathodic Protection Systems Using Ceramic Anodes.
d. UFGS-09965A, Painting; Hydraulic Structures and Appurtenant Works.
e. UFGS-13113A, Cathodic Protection Systems (Impressed Current) for Lock Miter
Gates.
f. TN ZMR-3-05, Components of Hydropower Projects Sensitive to Zebra Mussel
Infestations.
g. NACE International Recommended Practice RP0169-2002, Control of External
Corrosion on Underground or Submerged Metallic Piping Systems.
h. PROSPECT course handbook 009, 2003-01 et seq., Corrosion Control.
i. ERDC/CERL TR-01-73, Low-Maintenance Remotely Monitored Cathodic Protection
Systems Requirements, Evaluation, and Implementation Guidance (Vicki L. Van Blaricum,
William R. Norris, James B. Bushman, and Michael J. Szeliga), November 2001.
j. Calculations of Resistances to Ground (H. B. Dwight), Journ. AIEE Trans., vol 55,
1939, pp 1319 1328.

1-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
1-4. Background.
a. General. USACE uses CPSs in combination with protective coatings to mitigate
corrosion of hydraulic structures immersed in fresh, brackish, or salt water. Protective coatings
alone generally cannot offer complete corrosion protection because they usually contain some
pinholes, scratches, and connected porosity, and over time these imperfections become
increasingly permeable. As coatings degrade with time, these imperfections, commonly known
as holidays, have a profound effect on overall coating integrity because of underfilm corrosion.
CPSs, when used in conjunction with protective coatings, have been effective in controlling
corrosion. CPSs consist of anodes that pass a protective current to the structure through the
electrolyte environment. CPSs can be one of two types, sacrificial anode or impressed current
anode. Hybrid CPSs installed on structures can include both types of anodes to provide
protective current.
(1) Sacrificial CPSs. Sacrificial CPSs, also referred to frequently as galvanic CPSs, employ
sacrificial anodes such as specific magnesium- or zinc-based alloys, which are anodic relative to
the ferrous structure they are installed to protect. This inherent material property enables
sacrificial anodes to function without an external power source, so they generally need very little
maintenance after installation. However, by design, sacrificial anodes are consumed by
corrosion during their service life and must be replaced periodically in order to ensure continuing
protection of the structure. Therefore, these anodes should be installed in accessible locations on
the structure. Sacrificial anode CPSs are generally recommended for use with a well coated
structure that is expected to be well maintained or subjected to a minimum of damaging wear
during its design life. (Note that in this EM the terms sacrificial and galvanic may be used
interchangeably.)
(2) Impressed current CPSs. Impressed current systems employ anodes that are made of
durable materials that resist electrochemical wear or dissolution. The impressed current is
supplied by a power source such as a rectifier. All impressed current CPSs require periodic
maintenance because they employ a power supply and are more complex than sacrificial systems.
However, impressed current CPSs can be used effectively with bare or poorly coated structures
because these systems include much flexibility in terms of the amount of protective current
delivered and the ability to adjust it over time as conditions change.
b. Locations. Since 1950, USACE has used impressed current CPSs with graphite or highsilicon, chromium-bearing cast iron (HSCBCI) anodes. The first systems were installed on the
Mississippi River near Rock Island, IL, on an experimental basis. Since then, CPSs have been
used widely. About 22 CPSs were installed and are currently functioning on structures on the
Tennessee-Tombigbee Waterway, the Alabama River, and the Black Warrior River in the Mobile
District. CPSs have been used successfully on the Intercoastal Waterway on seven sector gates in
the Jacksonville District and on miter gates in the New Orleans District. Impressed current
systems have also been installed on three lock gates on the Columbia River in the Northwest.
1-2
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Similarly, impressed current systems using both graphite and HSCBCI anodes were installed on
lock gates on the Ohio River during the 1970s. However, ice and debris damage has made most
of these systems inoperable. Since the early 1980s, a new type of ceramic-coated composite
anode material has been used for various electrochemical processes, particularly in the
electrolytic production of chlorine and cathodic protection systems, including off-shore, water
tank, and groundbed applications. The mixed metal oxide ceramic-coated anodes consist of a
conductive coating of iridium or ruthenium oxide (IrO2 and RuO2, respectively) applied by
thermal decomposition onto specially prepared titanium substrates. The coatings are applied by
spraying aqueous metallic salts onto the titanium substrates and heating to several hundred
degrees Celsius. Multiple layers of coating material may be applied by the process to provide a
maximum coating thickness of approximately 0.025 mm (1 mil). This type of impressed current
CPS anode has been used at Pike Island and other locations with good results.
c. Inoperable impressed current systems. Most of the known inoperable impressed current
systems utilized graphite anodes that were more than 20 years old. Only a few navigation
structures have had systems that used sausage string cast iron anodes provided with impact
protection. Properly maintained and protected cast iron anode systems used in high-impact
debris areas have provided good results. Graphite systems in low-impact debris areas have also
shown good results.
d. Inoperable sacrificial anode systems. Zinc or magnesium sacrificial anodes provide
some benefits, but they typically protect only smaller areas of bare metal and, consistent with
their inherent material properties, they are consumed at higher rates than impressed current
anodes. In order to be beneficial, sacrificial anodes must continue to apply current to the
structure by design. Voltage testing must be conducted periodically and consumed anodes must
be replaced promptly to keep the system operating in accordance with applicable criteria.
e. Solutions.
(1) Restoration of systems. Most existing inoperable CPSs at navigation structures can be
restored. This approach is less expensive than installing complete new systems, and therefore
should be considered first. When graphite anode strings are consumed or destroyed, they can be
replaced with impact-protected cast iron sausage strings or ceramic-coated wire anodes. In many
cases, anode strings can be replaced and systems can be repaired without dewatering a lock.
(2) New or replacement systems. Designers should use UFGS-13113A with this manual for
new CPS installation or for complete system replacement when necessary.
f. Effective techniques. National Association of Corrosion Engineers (NACE)
Recommended Practice RP0169-2002 specifies techniques for control of external corrosion on
civil works hydraulic structures. It includes criteria for both coatings and cathodic protection,
and should be used in conjunction with guidance in this manual and with painting design
1-3
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
guidance in Engineer Manual EM 1110-2-3400. NACE RP0169-2002 should also be used as
guidance unless noted otherwise, and designers should become familiar with it.
g. Resistivity policy. Cathodic protection should be provided on all submerged metallic
structures. If, after performing a corrosion mitigation survey, an NACE-certified corrosion
specialist or a professional engineer deems cathodic protection unnecessary due to a
noncorrosive water, a statement to that effect should be prepared and sent to the district project
manager as a part of the corrosion plan.

1-4
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
CHAPTER 2
CORROSION MITIGATION PLAN
2-1. Corrosion Protection Coordinator. Each district should designate a person who has
experience and is familiar with cathodic protection techniques to serve as the district corrosion
protection coordinator. Such a person may be a licensed professional engineer or a person
certified as being qualified by NACE International as a cathodic protection specialist, corrosion
specialist, or senior corrosion technologist. This individual will be responsible for ensuring that
the CPSs are tested against the applicable corrosion protection criteria and for ensuring that
reports on the results of these tests are prepared and maintained at the district for review and
reference.
2-2. Plan.
a. Development. A corrosion mitigation plan should be developed by the district corrosion
protection coordinator for each hydraulic structure.
(1) New projects. A corrosion mitigation plan should be developed and included in the
design memorandum. For a previously completed design memorandum, the plan should be
developed and submitted as a supplement to the design memorandum prior to completion of
plans and specifications.
(2) Existing projects. A corrosion mitigation plan should be developed and presented as an
appendix in a Periodic Inspection Report for reference in subsequent inspections. Corrosion
mitigation plans should consider the condition of existing structures, factors that affect the rate of
corrosion, methods of corrosion control, and cathodic protection of the structure.
b. Execution. The following policy on optimization, testing, and reporting of the CPS for
each structure should be followed.
(1) A survey of the structure-to-electrolyte potential, using a standardized reference cell,
should be performed. Any system failing to operate in accordance with established criteria
should be optimized by adjustment.
(2) A report showing the condition of the CPSs and including any plans to repair the
systems should be prepared and kept at the district for review.
(3) Any inoperable CPS should be repaired as needed.

2-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
2-3. Tests and Adjustments.
a. Tests, adjustments, and data collection. Tests should be performed in accordance with
the corrosion mitigation plan. Rectifier voltages and currents should be recorded. There are no
prescribed time intervals for testing new systems, but measurements should be taken and
recorded monthly after initial energization or subsequent re-energization until steady-state
conditions are reached. Then, based upon the judgment of the corrosion protection coordinator,
tests should be performed at about 6-month intervals for a year or more, and thereafter at yearly
intervals. It would be appropriate to monitor critical or strategic structures more frequently.
Based upon the measurements taken, the rectifier current and voltage should be adjusted to
produce either a negative polarized (cathodic) potential of at least 850 mV with the cathodic
protection applied or other minimum cathodic polarization such as 100-mV polarization as
described in NACE RP0169-2002 for steel and cast iron piping. This potential should be
achieved over 90 percent of each face of each gate leaf. Readings should not exceed a polarized
(cathodic) potential of 1200 mV at any location. Acceptance criteria for CPSs should be as
defined in NACE RP0169-2002 unless otherwise noted in this manual.
b. Reports. Reports should be prepared and kept at the district. These reports should be
prepared in a format similar to that shown in the miter gate sample and table in Appendix A,
which presents measurements taken and data obtained. For other types of installations, the report
should be modified to show similar data applicable to the respective installation. This report
should be completed annually, not later than December.
c. Data. The data accumulated in these reports should be retained to provide a database
for consideration of possible improvements to CPS techniques. Reports on the current corrosion
deterioration status of the structures should be maintained.

2-2
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
CHAPTER 3
EXPERT ASSISTANCE
3-1. Background. Some USACE districts and laboratories have long been involved in planning,
designing, procuring, installing, testing, operating, and maintaining various types of CPSs for
navigation structures. Expertise is available to assist USACE elements in any of the above areas
on a cost reimbursable basis. For further information about USACE expert assistance in the
abovementioned areas, please contact the Corrosion Control and Cathodic Protection Systems
Directory of Expertise (DX) at Mobile District or CECW-E at HQUSACE.
3-2. Expertise Required. District personnel who have limited experience and expertise in CPSs
are encouraged to seek assistance from the Corrosion Control and Cathodic Protection Systems
Directory of Expertise (DX) and/or laboratories through their Corrosion Protection Coordinator.
The approval of a NACE-certified corrosion engineer is required for all new or replacement CPS
designs.
3-3. Types of Assistance Available. The specific areas of assistance include initial planning,
preparation and/or review of design and solicitation packages, review of design submittals,
review of shop drawings or contract changes, training, and preparation of corrosion mitigation
test plans. Assistance is also available, in troubleshooting, restoring, testing, and adjusting and
optimizing CPSs.
3-4. Element Responsibility. USACE elements will be responsible for ensuring that all
solicitations comply with current procurement policy, including consideration of the offerors
experience and qualifications. Although the procurement method selected for any given project
is at the discretion of the responsible element, the intent of this manual is to provide guidance so
that all contractors in cathodic protection have qualifications which, as a minimum, meet the
requirements in Chapter 6.

3-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
CHAPTER 4
TESTING AND OPTIMIZING
4-1. Equipment and Personnel. Test equipment should consist of a fresh and calibrated coppercopper-sulfate reference cell, a submersible connection, cabling suitable for immersion use, and a
high-impedance voltmeter capable of measuring polarized potentials with the CPS on.
Sensitivity should be more than 5 meg-ohms per volt. The reference electrode should be placed
in the electrolyte adjacent to and within 200 mm to the face of the gate at each test point. All
tests should be supervised by an NACE-certified corrosion specialist, senior corrosion
technologist, or cathodic protection specialist, a licensed corrosion engineer, or a Corps of
Engineers representative assigned and qualified to do this work.
4-2. Optimizing System. Data collected during the test should be reviewed, and any necessary
adjustments should be made. The system should be properly optimized by adjusting the rectifier
until 90 percent of the potentials fall within the range of polarized (cathodic) potential of
between negative 850 mV and negative 1200 mV, or 100-mV polarization according to NACE
RP0169-2002. A report on test results should be prepared and retained at the district. Research
and development work on low-cost remote monitoring systems has been performed recently to
increase reliability, extend service life, minimize maintenance requirements, and automate CPS
testing, evaluation, and diagnostic procedures in order to reduce CPS life-cycle costs (Van
Blaricum et al. 2001). For further information about CPS remote monitoring systems, contact
the Corrosion Control and Cathodic Protection Systems DX at Mobile District or CECW-E at
HQUSACE.

4-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
CHAPTER 5
SYSTEM SELECTION
5-1. Corrosion Protection. Corrosion occurs on all metallic structures that are not adequately
protected. The cost of replacing a structure which may have been destroyed or weakened due to
excessive corrosion is substantial but avoidable, and means should be taken to consistently
prevent or mitigate this added cost through cathodic protection. In addition to preparing and
applying protective coatings to the surface of a structure, corrosion protection can be provided by
applying a protective electric current to the structure surface which is immersed and in contact
with an electrolyte. In the presence of certain other metals contacting the electrolyte near the
structure, this technique transforms the structure into a cathodic electrode. A properly selected
and designed cathodic protection system can prevent surface corrosion of the structure, or
drastically reduce the rate at which it occurs.
5-2. Types of CPSs.
a. Sacrificial CPS. This type of system helps reduce surface corrosion of a metallic
structure immersed in an electrolyte by coupling a less noble metal with the structure. Sacrificial
CPSs work through the sacrifice of an anodic metal, i.e., one that has a negative electrochemical
potential relative to the protected ferrous structure, to prevent deterioration of the structure
through corrosion. Sacrificial anodes for fresh water applications typically are composed of
zinc- or magnesium-based alloys. In the past, installation of sacrificial anodes has often been
done on an ad hoc basis, relying largely on the installers individual knowledge and experience.
However, recent research on sacrificial anode materials has provided an improved engineering
basis for designing civil works applications of these systems.
b. Impressed current CPS. This type of system uses direct current applied to an anode
system from an external power source to drive the structure surface to an electrical state that is
cathodic in relation to other metals in the electrolyte. A number of impressed current anode
materials and geometries are used. Materials include mixed metal oxides, precious metals (e.g.,
platinum-clad titanium, niobium), and high-silicon chrome-bearing cast iron. The most common
geometries are slab or button anodes, rods, and strings. Any anode mounted on the structure
must be isolated with a dielectric shield to assure effective current distribution.
5-3. CPS Selection. When selecting which type of system to use, the designer should consider
the size of the structure to be protected and past project experience in operating and maintaining
both types of systems. Early in the selection process, if practical, it is useful to perform a current
requirement test to help define the total amount of electrical current needed to protect the
structure (see PROSPECT Corrosion Control course handbook [009, 2003-01 et seq]). For large
structures with significant expanses of bare or poorly coated metal, where the total current
requirement tends to be very high, a properly maintained impressed current system can provide
5-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
10 to 30 years of effective corrosion protection. Where current requirements are lower and the
structures protective coatings are well maintained, sacrificial anode systems can be very
effective. Improved modern coating systems and maintenance practices today allow for a wider
use of sacrificial CPSs on large civil works structures than was the case in the past. For both
types of systems, preliminary design estimations and comparisons of costs, current output, and
overall design life should give an adequate indication of which system is preferable for the
specific application. Other factors such as future maintenance needs, reliability, accessibility,
and impact on operations may also warrant consideration.
a. Basis for selecting an impressed current system.
(1) Can be designed for a wider range of voltage and current applications.
(2) Higher total capacity (i.e., ampere-years) can be obtained from each installation.
(3) One installation can protect an extensive area of the surface of a metallic structure.
(4) Voltage and current can be varied to meet changing conditions, providing operational
flexibility that is very useful to increase protection of the surface coating.
(5) Current requirement can be read and monitored easily at the rectifier.
(6) System can be designed to protect bare or poorly coated surfaces of metallic structures.
b. Basis for not selecting an impressed current system.
(1) First costs for design, acquisition, and installation are high.
(2) Installation is complex due to the need for an external power supply, cabling, and
numerous electrical connections.
(3) Maintenance costs can be high.
(4) System can create stray currents that may potentially corrode other nearby ferrous
structures.
(5) If an excessive amount of current output is used, hydrogen gas may form between the
substrate and coating, causing paint blistering or possible hydrogen-embrittlement of highstrength steel.
c. Basis for selecting a sacrificial anode system.

5-2
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
(1) External power source is not required.
(2) Installation is less complex since an external power source, including rectifier, is not
required.
(3) System works very well when electrolyte resistivity is low, surfaces are well coated,
structure is easily accessible, and significant deterioration of the coating is not expected within 5
to 10 years.
(4) System is easier to install on moving complex structures such as tainter valves where
routing of cables from an impressed current system could present a problem.
d. Basis for not selecting a sacrificial anode system.
(1) Current output per anode is low and may not be sufficient to protect large structures
with significant expanses of uncoated or poorly coated bare metal.
(2) System generally cannot be economically justified where large surface areas of a poorly
coated metallic structure require protection.
(3) Anode replacement expenses and/or the number of anodes required can be high
compared with impressed current systems for structures with high current requirements.
(4) Current output cannot easily be adapted to seasonal changes in water resistivity or to
unexpected changes in coating coverage caused by weathering, routine wear, or impact damage
due to debris, ice, or aquatic vessels.
(5) Due to the buildup of algae, silt, or other deposits on sacrificial anodes, current output to
the structure may be reduced.
(6) Monitoring system operation in accordance with NACE criteria is labor-intensive and
inconvenient because it requires that structure-to-electrolyte potential measurements be taken in
the field.

5-3
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
CHAPTER 6
SYSTEM DESIGN, CONSTRUCTION, OPERATION,
MAINTENANCE, AND RESTORATION
6-1. Design. For existing structures, a current requirement test should be made to accurately
assess the overall system design. The designer should become familiar with the availability and
suitability of types of commercially manufactured anodes which would satisfy the system
requirements for cathodic protection. Chapter 5 provides guidance for selecting impressed
current and sacrificial (i.e., galvanic) anode systems. The designer should become familiar with
manufacturer recommendations for use and product performance claims. CPSs should be
designed to attain and maintain a level of protection of the structure as defined in the section
Criteria and Other Considerations for Cathodic Protection in NACE RP0169-2002. In order to
achieve this level of protection, design calculations must be made to determine the number and
types of anodes required. Examples of calculations can be found in Appendix B of this manual
for impressed current cathodic protection design; in ETL 1110-9-10 for impressed current CPSs
using ceramic anodes; and in MIL-HDBK-1004/10, Electrical Engineering Cathodic
Protection, which was developed from evaluations, surveys, and design practices of the Naval
Facilities Engineering Command, other government agencies, and the private sector. Appendix C
of this manual provides engineering formulae and reference tables for use in designing sacrificial
CPSs for civil works applications, and Appendices D, E, and F present detailed examples of
sacrificial anode CPS design for different types and sizes of structures using various anode
geometries. MIL-HDBK-1004/10 can be a useful tool for design calculations in conjunction
with the criteria that follow. These calculations must take into consideration the total area of the
structure to be protected, the resistivity of the electrolyte, the present condition of the protective
coatings on the structure, the predicted deterioration of these coatings due to physical damage,
the normal paint change of state over a 20-year period, and the environment to which the
structure will be subjected. The design of CPSs should be accomplished under the supervision of
a NACE-certified corrosion specialist, a cathodic protection specialist, or a professional engineer
licensed in corrosion engineering.
a. Criteria. Design of civil works hydraulic structures shall conform to NACE RP01692002, paragraph 6.2.2 inclusive, Steel and Cast Iron Piping. Those criteria are specifically
included here by reference.
b. Guide specification. Unified Facilities Guide Specification UFGS-13113A, Cathodic
Protection Systems (Impressed Current) for Lock Miter Gates, should be used in preparing
contract documents for procurement of CPSs. This specification, in addition to providing the
technical requirements for various items of equipment for the CPS, addresses methods for
protection from ice and various debris of the string anodes and the electrical leads to the button
and string anodes. This specification is based upon the use of impressed current systems, which
are normally used on hydraulic structures having large areas requiring corrosion protection.
6-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Button anodes are normally used on the skin plate side of the gate, with rod or string anodes
installed in the compartment areas of the gate; however, button anodes may also be used in the
compartment areas if practical from an installation standpoint.
c. Zebra mussel guidance. In areas with potential for zebra mussel infestations, the CPS
components may be at risk of failure or disruption. Design considerations in preventing these
infestations should be included. For control strategies, refer to Zebra Mussel Research Technical
Note ZMR-3-05, compiled by the Zebra Mussel Research Program at Waterways Experiment
Station, Vicksburg, MS.
6-2. Construction. Installation of a CPS by a construction contractor should be accomplished
under the supervision of an NACE-certified corrosion specialist, senior corrosion technologist, or
cathodic protection specialist or a licensed corrosion engineer.
a. Services of corrosion engineer. The construction contractor should be required to obtain
the services of a licensed corrosion engineer to supervise the installation and testing of the CPS.
The term corrosion engineer refers to a person who has knowledge of the physical sciences and
the principles of engineering and mathematics, acquired by professional education and related
practical experience, and who is qualified to engage in the practice of corrosion control on
metallic structures. Such person may be a licensed professional corrosion engineer or may be
certified as being qualified by NACE International if such licensing or certification includes
suitable cathodic protection experience.
b. Workmanship. All material and equipment shall be installed in accordance with the
requirements of the specifications and as recommended by the corrosion engineer and approved
by the Contracting Officer. The installation, including testing, should be performed by an
organization that has had at least 3 years experience in this type of work.
6-3. Operation and Maintenance. The reliability and effectiveness of any CPS depend upon the
manner in which it is operated and maintained, as well as its proper design and installation.
a. Performance testing prior to acceptance. The primary purpose for testing of a CPS is to
determine if it has been optimized in accordance with and effectively meets design criteria
(typically RP0169-2002). A system that does not meet these criteria will not adequately protect
the structure against corrosion.
b. Operations and maintenance manual. An operations and maintenance manual should be
provided for each CPS installed. This manual should provide instructions for testing and
optimizing the system and should specify test equipment required. Copies of the structure-toelectrolyte potential measurements, obtained by the contractor at the time of acceptance of the
system by the Government, should be included for reference. Blank data sheets should be

6-2
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
provided for Government test personnel to record data obtained in future periodic testing of the
CPS.
c. Troubleshooting guide. A troubleshooting guide should be provided for use with the
CPS. This guide should address possible symptoms associated with failure of various items of
equipment of the system. Recommendations and possible solutions should also be included. If a
problem cannot be resolved by the corrosion protection coordinator, then it is recommended that
the designer seek the assistance addressed in Chapter 3 of this manual.
6-4. Restoration. Existing inoperable CPSs should be restored whenever possible and feasible.
Restoration of a CPS should be part of the corrosion mitigation plan and should include, but not
be limited to, the following:
a. A list of materials and cost.
b. An assessment of impact protection and consideration of the need for additional impact
protection devices.
c. A survey indicating the status and functional condition of rectifiers, anodes, terminal
cabinets, anode system cables, and impact devices.
d. A copy of the latest structure-to-reference-cell potential readings.

6-3
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
CHAPTER 7
TRAINING AND SERVICES
7-1. Training. Training should be provided for project designers, inspectors, and operation and
maintenance personnel who are responsible for CPSs in use at projects. Corrosion protection
coordinators should arrange with District Training Coordinators for this training. The training
should include both cathodic protection in general terms and report preparation. A PROSPECT
course on corrosion control is offered annually for district personnel. The course provides the
required CPS training on design and testing.
7-2. Services. Services are available on a cost-reimbursable basis from the Corrosion Control
and Cathodic Protection Systems DX at Mobile District, or the Engineer Research and
Development Center Construction Engineering Research Laboratory at Champaign, IL, to
assist districts in matters related to corrosion control and cathodic protection. Services are also
available for design, restoration, construction, operation and maintenance, and optimization
adjustments of CPSs. Services inquiries may be referred to CECW-E at HQUSACE.

7-1
More ebooks : http://artikel-software.com/blog

Free Download / Subscription Industrial and Engineering Magazines


http://magz.tradepub.com

or get directly on individual magazine below :

More free magazines ...

More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
APPENDIX A
SAMPLE CORROSION MITIGATION PLAN
CESAM-EN-CE
TO: Chief, Engineering Division
SUBJECT: Corrosion Mitigation Plan for Lock B Miter Gates, Tenn-Tom Waterway
1. OBJECTIVE: The objective of the subject plan is to provide methods for corrosion
mitigation of the submerged metallic structural components of the Lock B miter gates.
2. GENERAL: Lock B miter gates are located in a submerged corrosive environment in which
the water resistivity varies, but generally ranges between 40,000-60,000 ohm-mm. Galvanic
corrosion of the structural components of the lock miter gates can, and often does, result in
deterioration of the structural integrity of the gates. This deterioration can affect the operation of
the gates and often requires expensive repair and/or replacement of the gate or its structural
components. Weakening of the structural components of the gates may also cause failure of
seals, failure of gate alignment, or failure of quoin and miter blocks and a general deterioration
of the lock gates.
3. CORROSION MITIGATION: Corrosion of the metallic components of the gates can be
extensively reduced by the proper preparation and application of corrosion inhibiting coatings to
the gate surfaces. In addition, corrosion of the gates can be further reduced, and the life of the
applied coatings extended, by the installation of cathodic protection systems (CPSs).
a. Painting:
(1) Preparation of the ferrous surfaces of the gates and structural members, and the
selection and application of protective coatings, should be accomplished in accordance with the
requirements of UFGS-09965A, Painting; Hydraulic Structures and Appurtenant Works. The
stringent requirements of the guide specification, including the Safety and Health Provisions
detailed therein, should be adhered to.
(2) Ferrous surfaces of the gate structure should be cleaned to a grade approaching white
metal grade in accordance with UFGS-09965A. The surface anchor pattern shall be consistent
with the recommendations of the coating manufacturer. Quality control should be in accordance
with the requirements of this guide specification, and the method and minimum thickness of
application of the protective coatings specified therein should be adhered to. Proper surface
preparation is essential for achieving a good coating life.

A-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
b. Impressed Current: Installation of a CPS utilizing sacrificial anodes is considered an
inadequate method for cathodically protecting the Lock B miter gates. Impressed current
cathodic protection should therefore be applied using the guidance of CW-16643.
(1) A separate impressed current CPS should be provided for each gate leaf. Each
system should consist of a rectifier supplying protective current to anodes, which will distribute
protective current to the gate structure. Cathodic protection should be installed on those portions
of the gates submerged at normal pool levels. The faces of the gates should be protected to upper
pool stages, except that the downstream face of the lower gates should be protected to the lower
pool. Meters should be provided as part of the rectifier to monitor the CPS voltage and current.
(2) This navigation lock will be subject to flooding and floating debris; therefore, the
CPS should be designed to permit for removal during periods of high water, and the anode cables
and sausage-type anodes will require impact protection to prevent them from being damaged.
4. MAINTENANCE AND MONITORING: Maintenance and monitoring of the CPS (sacrificial
or impressed current) are essential to ensure continuing corrosion protection. The areas of the
lock gates to receive cathodic protection are those areas of the gates already stipulated in
paragraph 3b(1). Monitoring and evaluations should be accomplished as follows:
a. The voltage and current readings of the rectifiers should be observed, monitored, and
recorded daily. DC voltage and current data indicate that the rectifiers and CPS are working but
do not guarantee that the system is properly optimized. Typical information on voltage and
current data recordings is as follows:
GATE

VOLTS

AMPS

Upper - left leaf

14.5

0.3

Upper - right leaf

14.2

0.3

Lower - left leaf

11.4

0.6

Lower - right leaf

10.8

0.4

b. The evaluation of annual reference cell voltage data indicating the structure-toelectrolyte (lock-to-water) potential is the accepted method for determining the adequacy of
corrosion protection provided by the CPS. Reference cell data are evaluated based on the design
(anode locations), the voltage adjustments, and the adequacy of the test locations. Adjustments
to the rectifier output can be made to improve the protective potentials applied to the gate leaves.
Attached Table A-1 provides details on typical reference cell data.
(Name)
(Position)

A-2
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE A-1
(Impressed Current Installation)
RECTIFIER NO. 1
Upper Gate - Land Leaf - Upstream Side
*
Steel to Half-Cell Potentials
Reports Control Symbol ENGW-E-7
Date of test: 1 Oct. 1991

Depth
Below
Water
Surface
mm

Pre-Protection

Current On

Quoin
End

Middle

Miter
End

Quoin
End

Middle

Miter
End

Quoin
End

Middle

Miter
End

150

-0.500

-0.505

-0.495

-1.050

-1.000

-1.055

-0.655

-0.700

-0.650*

600

-0.500

-0.500

-0.500

-1.040

-1.030

-1.035

-0.700

-0.735

-0.705

1200

-0.500

-0.500

-0.500

-1.050

-1.085

-1.050

-0.825

-0.755

-0.815

1850

-0.500

-0.495

-0.495

-1.050

-1.100

-1.055

-0.855

-0.765

-0.850

2450

-0.495

-0.490

-0.490

-1.050

-1.085

-1.050

-0.865

-0.770

-0.850

3050

-0.490

-0.480

-0.485

-1.080

-1.110

-1.070

-0.880

-0.880

-0.850**

3650

-0.490

-0.480

-0.480

-1.070

-1.080

-1.060

-0.885

-0.880

-0.880

4250

-0.480

-0.479

-0.470

-1.070

-1.070

-1.065

-0.880

-0.885

-0.980

4900

-0.470

-0.464

-0.460

-1.000

-1.020

-1.030

-0.885

-0.890

-0.980

5500

-0.465

-0.455

-0.450

-1.000

-0.979

-1.050

-0.880

-0.885

-0.985

6100

-0.460

-0.445

-0.440

-0.950

-0.930

-1.000

-0.870

-0.875

-0.1075

Rectifier voltage = 2.10 volts


Rectifier current = 0.50 amps
Coarse tap position = L
Fine tap position = 2
Meter used 5 meg ohms/volt 2 volt scale
Half-cell 75 mm or less from lock steel
Resistance of circuit: E = IR
2.10 = .5R
R = 2.10/.5 = 4 ohms

Current Off

NOTE: Include as many 600-mm (2-ft)


increments as necessary to cover submerged depth
of gate

* Unacceptable reading
** Acceptable reading

* All potential measurements are expressed in units of direct current (DC) volts with respect to a copper/copper sulfate half cell.

A-3
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
APPENDIX B
DETAILED CATHODIC PROTECTION DESIGN PROCEDURES FOR PIKE ISLAND
AUXILIARY LOCK GATES
Designs for Lock Gates.
Figure B-1 shows a Pike Island auxiliary miter gate. This gate is approximately 18.85 m (62 ft)
long and 10.64 m (35 ft) high. With the river at normal water level, portions of each gate will
always be submerged, and other portions may be submerged or exposed as lockages occur.
During times of high water, more gate surfaces will be submerged, and, under conditions of
flood, the entire gates may be submerged. The usual water depth is 9.12 m (30 ft).

FIGURE B-1. PIKE ISLAND AUXILIARY LOCK MITER GATE


The gates are constructed of welded structural steel, horizontally framed, with a cast pintle. The
downstream side of the gate consists of a pattern of rectangular chambers closed on five faces
and open to the water on the sixth face. The upstream face of the gate is made up of a large skin
plate over the major portion of the face and two columns of small chambers at the quoin and
miter ends of the gate.
The main (large) chambers on the downstream face of the gate are set in four columns and are
approximately 3.66 m (12 ft) wide, varying in height from 1.01 m (3 ft 4 in.) to 1.82 m (6 ft),
with a depth of 1.06 m (3 ft 6 in.). The two sets of vertically aligned chambers, at the quoin and
miter ends of the gates, are much smaller and irregularly shaped. There are 6 horizontally
aligned rows of chambers placed one above the other in each vertical column, giving a total of 48
chambers on the downstream side.
B-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Design Data.
a. The lock is located in fresh water with a resistivity of 3000 ohm-centimeters.
b. Water velocity is less than 1524 mm/s (5 ft/s).
c. Water contains debris, and icing will occur in the winter.
d. The gate surfaces have a new vinyl paint coating, minimum of 0.15 mm (6 mils) thick,
with not more than 1 percent of the area bare because of holidays in the coating.
e. The coating will deteriorate significantly in 20 years of exposure. Experience shows
that 30 percent of the area will become bare in 20 years.
f. Design for 75.35 mA/m2 (7.0 mA/ft2) (moving fresh water).
g. Electric power is available at 120/240 volts AC, single phase at the lock site.
h. Design for a 20-year life.
i. Design for entire surface of the gate to be submerged.
j. Base anode requirement on the average current requirement over the anode design life.
k. Base rectifier requirement on maximum (final) current requirement at end of anode
design life.
Computations.
Find the surface area to be protected.
a. Upstream side
2
2
Area of skin plate: 14.51 m x 10.67 m = 154.82 m (1666 ft )

Chamber areas at each end (same at each end):

6 chambers @ 6.50 m2 = 39.02 m2 (420 ft2)


6 chambers @ 3.72 m2 = 22.30 m2 (240 ft2)
6 chambers in each vertical column
b. Downstream side
B-2
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Number of Chambers

Chamber Area
m2 (ft2)

Total Area
m2 (ft2)

4
4
4
4
4
4
4
4
4
2
4
2
2
2

5.85 (63)
6.60 (71)
7.06 (76)
8.08 (87)
8.55 (92)
13.47 (145)
14.68 (158)
15.51 (167)
16.63 (179)
17.28 (186)
18.12 (195)
19.14 (206)
21.18 (228)
22.20 (239)

23.41 (252)
26.34 (284)
28.24 (304)
32.33 (348)
34.19 (368)
53.88 (580)
58.71 (632)
62.06 (668)
66.52 (716)
34.56 (372)
72.46 (780)
38.28 (412)
42.36 (456)
44.40 (478)

Total number of chambers = 48


2
2
Total chamber area = 194.17 m (2092 ft )
2
2
Total area = 617.81 m (6650 ft )

2)

Calculate the current requirements (I) from Equation 1.

I = A* I (1.0 - CE )

[EQ 1]

where
A=

surface area to be protected (varies depending on portion of structure)

I' =

required current density to adequately protect gate 75.35 mA/m2

CE = coating efficiency (0.99 initial, and 0.70 final)


A) Upstream side

Skin plate current requirement

Calculate I

where A = 154.82 m (1666 ft ) (from computation step 1A).

B-3
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Initial current requirement (CE = 99%):
2

I = 154.82 m x 75.35 mA/m x (1 - 0.99) = 116 mA (use 120 mA)

Final current requirement (CE = 70%):


2

I = 154.82 m x 75.35 mA/m x (1 - 0.70) = 3498 mA (use 3500mA)

Average current requirement:

I = (120 + 3500)/2 mA = 1810 mA (use step 2A for skin plate)

End chamber current requirement

To be able to use the same anode assembly in each set of chambers, base the design on the larger of the
two chambers at each end.
Calculate I

where A = 39.02 m (420 ft ) (from computation step 1A).

Initial current requirement (CE = 99%):


2

I = 39.02 m x 75.35 mA/m x (1 - 0.99) = 29.4 mA (use 30 mA for 6 chambers)

Final current requirement (CE = 70%):


2

I = 39.02 m x 75.35 mA/m x (1 - 0.70) = 882 mA (use 900 mA per 6 chambers)

Average current requirement:

I = (30 + 900)/2 = 465 mA per 6 chambers (use 0.5 per 6 chambers in a vertical

B-4
More ebooks : http://artikel-software.com/blog

column).

EM 1110-2-2704
12 Jul 04
This is current requirement for one vertical column of 6 chambers. Total average current requirement is
four times this amount:
I = 0.5 x 4 = 2.0 A for chamber

Total current requirement (IT) for upstream side:

IT = 120 mA + (4 x 30 mA) = 240 mA = 0.24 amps (initial)


IT = 2.0 A + 2.0 A = 4.0 amperes (average)
IT = 3500 mA + (4 x 900 mA) = 7100 mA = 7.10 amps (final)
B) Downstream side

Calculate I

where A = 22.20 m (239 ft ) (from computational step 1B).

Initial current requirement (CE = 99%):


2

I = 22.20 m x 75.35 mA/m x (1 - 0.99) = 16.8 mA per chamber

Final current requirement (CE = 70%):


2

I = 22.20 m x 75.35 mA/m x (1 - 0.70) = 502 mA per chamber

Average current requirement:

I = (16.8 + 502)/2 = 260 mA per chamber

Total current requirement for downstream side (48 chambers):

IT = 16.8 mA/chamber x 48 chamber = 806 mA = 0.8 A (initial)

B-5
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
IT = 260 mA/chamber x 48 chamber = 12,480 mA = 12.4 A (average)
IT = 502 mA/chamber x 48 chamber = 224,096 mA = 24.2 A (final)
C) Total current requirement

Initial

Upstream side

= 0.24 amps

Downstream side = 0.80 amps


1.04 amps
Average

Upstream side

= 4.0 amps

Downstream side = 12.4 amps


16.4 amps
Final

Upstream side

= 7.1 amps

Downstream side = 24.2 amps


31.3 amps

Note: Average current requirements determine anode selection. Final current requirements
determine rectifier selection.
3)

Select the anode and calculate the number of anodes required (N) to meet the design life
requirements.

Disk anodes such as those shown in Figure B-2 are considered best for the skin plate on the
upstream side. Either 3.2-mm- (1/8-in.-) diam segmented rod anodes consisting of 1,219-mm (4-

B-6
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
ft) segments, as shown in Figure B-3, or continuous 3.2-mm- (1/8-in.-) diam prefabricated rod
anodes are considered best for the chambers.

FIGURE B-2. TYPICAL CERAMIC-COATED FLAT DISK ANODE

FIGURE B-3. TYPICAL CERAMIC-COATED ROD ANODE DESIGN


For this example, the design based on the 1219-mm (4-ft) segments. The design for the
continuous rod material would be identical since they have the same amperage capacity per lineal
foot of anode material. Number of anodes is calculated from Equation 2:

N=

[EQ 2]

IA
B-7
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
where
I = total current requirement
IA = average current per anode for the anode's desired life.
A) Upstream side

Skin plate - number of disk anodes

Calculate N where:
I = 2 A (from step 2A)
IA = 0.84 A/disk anode

N=

2
= 2.4 anodes
0.84

Use 3 disk anodes.


Chambers - number of segmented rod anodes

For each set of 6 chambers in a vertical column


Calculate N

N=
where

0.5
= 0.5 anodes
1

I = 0.5 A (from step 2A)


IA = 1.0 A/1219-mm- (4-ft-) long segmented rod (from Table B-1M
(Metric)/B-1 (U.S. Customary))

Use 1 segmented rod anode per 6 vertical chambers.

B-8
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
B) Downstream side

I = 260 mA per chamber

For each set of 6 chambers in a vertical column


I = 6 x 260 mA = 1560 mA = 1.56A
IA = 1.0 A/anode (from Table B-1M/B-1)

N=

4)

1.56
= 1.56 anodes; use 2 segmented rod anodes per 6 vertical chambers
1
Select number of anodes to provide adequate current distribution.

A) Upstream side

Skin plate

Experience shows that an anode grid spacing of 3.048 to 3.658 m (10 to 12 ft) provides adequate
coverage of protective current. Additional anodes are also needed along the bottom of the gate,
as this is an area where coating damage occurs readily, thus exposing an appreciable amount of
bare metal. Figure B-4 shows a suitable configuration using a combination of 19 disk anodes.

FIGURE B-4. AUXILIARY LOCK MITER GATE DESIGN AT PIKE ISLAND

B-9
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE B-1M (METRIC)
DIMENSIONS AND RATINGS OF CERAMIC ANODES
Underground Usage
Wire and Rod Anodes (Packaged)
Current Rating, amps
10-Year
Design
Life

15-Year Design
Life

20-Year
Design Life

Anode Element
Dimension
mm x mm

Package Size
mm

Weight
kg

HDC

HDC

SC

HDC

SC

3.2 x 610
1.6 x 1524
1.6 x 1524

51 x 762
51 x 1829
76 x 1829

13.22
30.86
57.32

1.3
1.5
1.5

1.10
1.25
1.25

0.6
0.7
0.7

0.9
1.0
1.0

0.5
0.6
0.6

3.2 x 1219
3.2 x 1219
6.4 x 1219
3.2 x 1829

51 x 1524
76 x 1524
76 x 1524
76 x 2438

26.45
48.50
48.50
77.16

2.7
2.7
5.5
4.0

2.2
2.2
4.4
3.3

1.2
1.2
2.4
1.8

1.8
1.8
3.5
2.7

1.0
1.0
2.0
1.5

9.5 x 1219
12.7 x 1219
19 x 1219

76 x 1524
76 x 1524
76 x 1524

48.50
50.70
55.11

7.5
10.0
15.0

6.0
8.0
12.0

3.6
4.8
7.2

5.1
6.8
10.0

3.0
4.0
6.0

3.2 x 1829
6.4 x 1829

76 x 2438
76 x 2438

77.16
77.16

4.0
8.2

3.3
6.6

1.8
3.6

2.7
5.3

1.5
3.0

3.2 x 2438
6.4 x 2438

76 x 3048
76 x 3048

97.00
97.00

5.4
11.0

4.4
8.8

2.4
4.8

3.6
7.0

2.0
4.0

Note: HDC = heavy duty coating tubular anodes (in coke breeze).
SC = standard coating tubular anodes (in coke breeze).

Anode Element Dimension, mm x mm

20-Year Design Life


Current Rating, amps

25.4 x 250
25.4 x 500
25.4 x 1000
16 x 250
16 x 500
16 x 1000

2.00
4.00
8.00
1.25
2.50
5.00

B-10
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE B-1M (CONT'D)
FRESH AND SEAWATER USAGE
Wire and Rod Anodes (Bare)

Life (years)

Fresh Water

Brackish Water

Seawater

Maximum Current(A)/305-mm Length for 20-Year Design Life of 1.6-mm-diam Wire


10
15
20

0.39
0.31
0.26

0.51
0.44
0.39

0.85
0.74
0.67

Maximum Current(A)/305-mm Length for 20-Year Design Life of 3.2-mm-diam Rod or Wire
10
15
20

0.79
0.62
0.52

1.02
0.88
0.79

1.7
1.47
1.33

Maximum Current(A)/305-mm Length for 20-Year Design Life of 6.4-mm-diam Rod


10
15
20

1.58
1.24
1.04

2.04
1.76
1.58

3.41
2.95
2.66

Maximum Current(A)/305-mm Length for 20-Year Design Life of 8.3-mm-diam Rod


10
15
20

2.37
1.85
1.56

3.06
2.63
2.37

5.11
4.42
3.99

Maximum Current(A)/305-mm Length for 20-Year Design Life of 12.7-mm-diam Rod


10
15
20

3.16
2.47
2.08

4.08
3.51
3.16

6.81
5.9
5.33

Maximum Current(A)/305-mm Length for 20-Year Design Life of 15.9-mm-diam Rod


10
15
20

3.95
3.09
2.6

5.1
4.39
3.95

8.52
7.37
6.66

Maximum Current(A)/305-mm Length for 20-Year Design Life of 19-mm-diam Rod


10
15
20

4.74
3.71
3.12

6.12
5.27
4.74

B-11
More ebooks : http://artikel-software.com/blog

10.22
8.85
7.99

EM 1110-2-2704
12 Jul 04
TABLE B-1M (CONT'D)
FRESH AND SEAWATER USAGE
Tubular Anodes (Bare)
Seawater - Current in amps per anode (15-year design life)
25.4 mm x 500 mm
25.4 mm x 1000 mm
16 mm x 500 mm
16 mm x 1000 mm

25 amps
50 amps
15 amps
30 amps

Sea Mud - Current in amps per anode (20-year design life)


25.4 mm x 500 mm
25.4 mm x 1000 mm

6 amps
12 amps

Fresh Water - Current in amps per anode (20-year design life)


25.4 mm x 500 mm
25.4 mm x 1000 mm
16 mm x 500 mm
16 mm x 1000 mm

4.00 amps
8.00 amps
2.50 amps
5.00 amps

Current Density Limitations


Wire and Rod Anode
2

Anode Life Versus Maximum Current Density (amps per 0.0929 m )

Life, years

Coke

Fresh Water

Brackish Water

Seawater

10
15
20

19
15
13

24
19
16

31
27
24

52
45
41

Tubular Anodes
2

Anode Life Versus Maximum Current Density (amps per 0.0929 m )

Life, years

Fresh Water

Brackish Water

Seawater

20

9.3

9.3

56

B-12
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE B-1M (CONCLUDED)
Disk Anodes (see Figure B-2)

Size:
Active Area:
Weight:

127 mm diam (typical - other sizes available)


2
12,258 mm
907 g
Fresh Water

Salt Water

Current capacity - 20-year life (amps/anode)

0.84

5.00

Operating voltage - 20-year life (V)

20.0

10.0

Segmented Rod Anodes (see Figure B-3)

Size:
Active Area:
Weight:

1219-mm length; 3.5-mm diam


2
14,194 mm
65 g
Fresh Water

Salt Water

Current capacity - 20-year life (amps/anode)*

1.00

2.50

Operating voltage - 20-year life (V)

50.0

10.0

* Standard coating.

B-13
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE B-1(U.S. CUSTOMARY)
DIMENSIONS AND RATINGS OF CERAMIC ANODES
Underground Usage
Wire and Rod Anodes (Packaged)
Current Rating, amps
10-Year
Design
Life

15-Year Design
Life

20-Year
Design Life

Anode Element
Dimension

Package
Size, in.

Weight
lb

HDC

HDC

SC

HDC

SC

1/8 " x 2'


1/16" x 5'
1/16" x 5'

2 x 30
2 x 72
3 x 72

6
14
26

1.3
1.5
1.5

1.10
1.25
1.25

0.6
0.7
0.7

0.9
1.0
1.0

0.5
0.6
0.6

1/8" x 4'
1/8" x 4'
1/4" x 4'
1/8" x 6'

2 x 60
3 x 60
3 x 60
3 x 96

12
22
22
35

2.7
2.7
5.5
4.0

2.2
2.2
4.4
3.3

1.2
1.2
2.4
1.8

1.8
1.8
3.5
2.7

1.0
1.0
2.0
1.5

3/8" x 4'
1/2" x 4'
3/4" x 4'

3 x 60
3 x 60
3 x 60

22
23
25

7.5
10.0
15.0

6.0
8.0
12.0

3.6
4.8
7.2

5.1
6.8
10.0

3.0
4.0
6.0

1/8" x 6'
1/4" x 6'

3 x 96
3 x 96

35
35

4.0
8.2

3.3
6.6

1.8
3.6

2.7
5.3

1.5
3.0

1/8" x 8'
1/4" x 8'

3 x 120
3 x 120

44
44

5.4
11.0

4.4
8.8

2.4
4.8

3.6
7.0

2.0
4.0

Note: HDC = heavy duty coating tubular anodes (in coke breeze).
SC = standard coating tubular anodes (in coke breeze).
Anode Element Dimension

20-Year Design Life


Current Rating, amps

1" x 9.8"
1" x 19.7"
1 " x 39.4"
0.63" x 9.8"
0.63" x 19.7"
0.63" x 39.4"

2.00
4.00
8.00
1.25
2.50
5.00

B-14
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE B-1 (CONT'D)
FRESH AND SEAWATER USAGE
Wire and Rod Anodes (Bare)

Life (years)

Fresh Water

Brackish Water

Seawater

Maximum Current/l-ft Length for 20-Year Design Life of .0625-in.-diam Wire


10
15
20

0.39
0.31
0.26

0.51
0.44
0.39

0.85
0.74
0.67

Maximum Current/l-ft Length for 20-Year Design Life of .125-in.-diam Rod or Wire
10
15
20

0.79
0.62
0.52

1.02
0.88
0.79

1.7
1.47
1.33

Maximum Current/l-ft Length for 20-Year Design Life of .25-in.-diam Rod


10
15
20

1.58
1.24
1.04

2.04
1.76
1.58

3.41
2.95
2.66

Maximum Current/l-ft Length for 20-Year Design Life of .325-in.-diam Rod


10
15
20

2.37
1.85
1.56

3.06
2.63
2.37

5.11
4.42
3.99

Maximum Current/l-ft Length for 20-Year Design Life of .5-in.-diam Rod


10
15
20

3.16
2.47
2.08

4.08
3.51
3.16

6.81
5.9
5.33

Maximum Current/l-ft Length for 20-Year Design Life of .625-in.-diam Rod


10
15
20

3.95
3.09
2.6

5.1
4.39
3.95

8.52
7.37
6.66

Maximum Current/l-ft Length for 20-Year Design Life of .75-in.-diam Rod


10
15
20

4.74
3.71
3.12

6.12
5.27
4.74

B-15
More ebooks : http://artikel-software.com/blog

10.22
8.85
7.99

EM 1110-2-2704
12 Jul 04
TABLE B-1 (CONT'D)
FRESH AND SEAWATER USAGE
Tubular Anodes (Bare)
Seawater - Current in amps per anode (15-year design life)
1 in. x 19.7 in.
1 in. x 39.4 in.
0.63 in. x 19.7 in.
0.63 in. x 39.4 in.

25 amps
50 amps
15 amps
30 amps

Sea Mud - Current in amps per anode (20-year design life)


1 in. x 19.7 in.
1 in. x 39.4 in.

6 amps
12 amps

Fresh Water - Current in amps per anode (20-year design life)


1 in. x 19.7 in.
1 in. x 39.4 in.
0.63 in. x 19.7 in.
0.63 in. x 39.4 in.

4.00 amps
8.00 amps
2.50 amps
5.00 amps

Current Density Limitations


Wire and Rod Anode
Anode Life Versus Maximum Current Density (amps/sq ft)

Life, years

Coke

Fresh Water

Brackish Water

Seawater

10
15
20

19
15
13

24
19
16

31
27
24

52
45
41

Tubular Anodes
Anode Life Versus Maximum Current Density (amps/sq ft)

Life, years

Fresh Water

Brackish Water

Seawater

20

9.3

9.3

56

B-16
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE B-1 (CONCLUDED)
Disk Anodes (see Figure B-2)

Size:
Active Area:
Weight:

5-in. diam (typical - other sizes available)


19 sq in.
2.0 lb
Fresh Water

Salt Water

Current capacity - 20-year life (amps/anode)

0.84

5.00

Operating voltage - 20-year life (V)

20.0

10.0

Segmented Rod Anodes (see Figure B-3)

Size:
Active Area:
Weight:

4-ft length; 0.138-in. diam


22 sq in.
2.3 oz
Fresh Water

Salt Water

Current capacity - 20-year life (amps/anode)*

1.00

2.50

Operating voltage - 20-year life (V)

50.0

10.0

* Standard coating.

Chambers
A continuous length of screw-coupled segmented rod anodes is needed for each chamber column
at the miter and quoin ends extending from the high-water line down to within 610 mm (2 ft) of
the bottom girder. Each anode consists of 7 segments, each 1219 mm (4 ft) in length. Four
segmented rod anode assemblies are thus required, comprising a total of 28 segments, each 1219
mm (4 ft) in length. See Figure B-5.

B-17
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04

FIGURE B-5. AUXILIARY LOCK MITER GATE AT


PIKE ISLAND SHOWING ROD ANODE PLACEMENT
Total anodes required for the upstream side:

19 disk anodes
4 segmented rod anodes (28 individual rod segments)
B) Downstream side

One continuous length of screw-coupled segmented rod anodes is needed for each chamber
column extending from the high-water line down to within 610 mm (2 ft) of the bottom girder.
(Note: For the downstream side of the downstream gates, a much shorter anode length will be
required since only the lower portions of this gate surface are ever submerged.) Each anode rod
consists of 7 segments, each 1219 mm (4 ft) in length. Eight segmented rod anodes are thus
required, comprising a total of 56 segments, each 1219 mm (4 feet) in length. See Figure B-5.
5)

Determine the anode-to-water resistance (RA) of the individual anodes.

Disk anodes

Empirical information indicates anode-to-water resistance (RA) of a single 127-mm (5-in.) disk
anode on a coated structure may be expressed by Equation 3.
B-18
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04

RA =

p
21.5

[EQ 3]

where p = 3000 ohm-cm (water resistivity from design item 1)


21.5 = Manufacturer correlation constant for 127-mm flat disk anode used
to yield ohms

RA =

3000
= 139.5 ohms
21.5

The disk anode-to-water resistance (RN) of the 19 disk anodes can be approximated from
Equation 4.
R N = R A /N+ (p* P F) / CC
where:

[EQ 4]

RA

139.5 ohms (disk anode-to-water resistance of individual disk anodes from


previous calculation)

19 (number of anodes, design step 4)

3000 ohm-cm

PF

0.0427 (paralleling factor from Table B-2M (metric)/B-2


(U.S. customary)

CC

304.8 cm (10 ft) (center-to-center spacing of disc anodes).

RN = 139.5/19 + (3000 x 0.0427)/(304.8 cm) = 7.7 ohms

At the maximum expected current of 3500 mA (3.5 amps), the voltage required for the disk
anodes can be determined using Ohm's Law, Equation 5.

E=IxR

[EQ 5]

B-19
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
E = 3.5 x 7.7 = 27 volts

This is a reasonable voltage, so the 19 disk anodes are sufficient


Segmented rod anodes

The segmented rod anode-to-water resistance (RA) is calculated from Equation 6. the total
length of anode is used, although a shorter length could be used if low water conditions were
expected most of the time.

RA =

where

Kp
[ln(8 L/d) - 1]
L

[EQ 6]

3000 ohm-cm (water resistivity from design item 1)

853 cm (28 ft) (length of anode rod from design step 4)

0.35 cm (0.0115 ft) (anode rod diameter)

0.158 (metric)

0.0052 (U.S. customary)

RA =

0.158 3000 8 853


- 1
x ln
0.35
853

R A = 0.557 (9.88 - 1) = 4.95 ohms

B-20
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE B-2M (METRIC)
ANODE PARALLELING FACTORS FOR VARIOUS NUMBER OF
Anodes Installed in Parallel
N

0.0796

14

0.0512

0.0881

16

0.0472

0.0863

18

0.0442

0.0817

20

0.0411

0.0768

22

0.0390

0.0722

24

0.0369

0.0683

26

0.0347

0.0646

28

0.0332

10

0.0613

30

0.0317

12

0.0555

Note: N = number of anodes; P = paralleling factors

TABLE B-2 (U.S. CUSTOMARY)


ANODE PARALLELING FACTORS FOR VARIOUS NUMBER OF
Anodes Installed in Parallel
N

0.00261

14

0.00168

0.00289

16

0.00155

0.00283

18

0.00145

0.00268

20

0.00135

0.00252

22

0.00128

0.00237

24

0.00121

0.00224

26

0.00114

0.00212

28

0.00109

10

0.00201

30

0.00104

12

0.00182

Note: N = number of anodes; P = paralleling factors

Voltage for upstream side rod anodes

At the maximum expected current requirement for the upstream chambers of 900 mA per vertical
column of 6 chambers, the voltage required for each rod anode can be determined using Ohm's
Law, Equation 5.

B-21
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
E = I x R = 0.90 amps x 4.95 ohms = 4.46 volts

This is a reasonable voltage, so the single anode per column of chambers is sufficient.
Voltage for downstream side rod anodes

At the maximum expected current of 251 mA per chamber, the current required for one vertical
column of 6 chambers is:
I = 6 x 502 mA = 3012 mA or 3.0 amperes

The voltage required for each anode is found using Equation 5:


E = I x R = 3.0 amps x 4.95 ohms = 14.9 volts

This is a reasonable voltage, so the single anode per vertical column of chamber is sufficient.
6)

Determine total circuit resistance (RT) using Equation 7.

RT = R N + RW + RC
where:

[EQ 7]

RN = anode-to-water resistance
RW = header cable/wire resistance
RC = tank-to-water resistance

A) Upstream side
Skin Plate
RN = 7.7 ohms (anode-to-water resistance)
RW = 0.02 ohms (wire resistance)

R depends on the actual wiring of the anodes, but the general arrangement would be to use a
header cable from the rectifier to the center of the disk anode array and then distribute the current
through a junction box to each anode. Wiring would be in a conduit on the inside of the gate.
Assuming the rectifier is 8.53 m (28 ft) from the gate, there will be about 30.48 m (100 ft) of
positive and negative header cable. No. 2 AWG, HMWPE insulated cable is selected. The
W

B-22
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
resistance of the anode distribution wiring is considered negligible. The header cable resistance
is calculated from Equation 8.

RW =

where

LW R MFT
1000

[EQ 8]

LW = 30.48 m (100 ft) (header cable length (as noted above))


RMFT = 0.159 ohms (resistance per 304.8 m (1000 linear ft) of No. 2 AWG HMWPE)

RW =

30.48 x 0.159
= 0.016 ohms; use 0.02 ohms
304.8

RC = 0.00 ohms (structure-to-water resistance)

RC is considered negligible since the design maximum capacity is based on a 30 percent bare
structure which would have negligible resistance.
The total resistance RT of the skin plate disk anode system using Equation 7 is:
RT = RN + RW + RC = 7.7 + 0.02 + 0.0 = 7.72 ohms
Chambers

Total resistance of the 4 upstream chamber anodes (RN) is calculated as follows: The four anode
rods are in parallel. Total resistance can be determined from the law of parallel circuits. Since
all four anodes have the same anode-to-water resistance, the calculation becomes Equation 9.
R N = R A /N = 4.95 / 4 = 1.24 ohms
where:

[EQ 9]

RN = total resistance of all four anodes


RA = 4.95 (anode-to-water resistance)
N = 4 (number of anodes)

RW = 0.01 ohms (wire resistance)

B-23
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
RW consists of a No. 2 AWG, HMWPE insulated cable. The rectifier will be located about 7.62
m (25 ft) from the gate, requiring 15.24 m (50 ft) of positive and negative header cable to the
gate.
There will be about 18.29 m (60 ft) of cable on the gate. One half of the cable resistance is used
in the calculation to allow for distribution of current.
Total wire length then is: 15.24 m + 9.14 m = 24.38 m (80 ft)
Resistance, RW, is calculated from Equation 8:

RW =

where:

LW R MFT
1000

[EQ 8]

LW = 24.38 m (80 ft) (header cable length (as noted above))


RMFT = 0.159 ohms (resistance per 304.8 m (1000 linear ft) of No. 2
HMWPE)

RW =

AWG

24.38 x 0.159
= 0.01ohms
304.8

RC = 0.00 ohms (structure-to-water resistance is negligible)

Total resistance (RT ) of the upstream chamber system then from Equation 7:
RT = R N + RW + RC

[EQ 7]

RT = 1.24 + 0.01 + 0.0 = 1.25 ohms


B) Downstream side

Calculations are similar to those from the upstream chambers. Anode-to-water resistance, RN,
from Equation 9 is:
RN = RA/N
where:

RA = 4.95 ohms (from design step 5).

B-24
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
N = eight anode rods (from design step 3).
RN = 4.95/8 = 0.62 ohms
RW = 0.01 ohms wire resistance (wire length and resistance is the same
as the upstream side).

Total resistance (RT) from Equation 7:


RT = RN + RW + RC = 0.62 + 0.01 + 0.0 = 0.63 ohms
7)

Determine required rectifier voltage (VREC) and current.


A) Upstream side

Skin plate
Maximum current required: 3.50 A (step 2A)
Resistance: 7.72 ohms (from step 6A)
Voltage required, Equation 5: E = I x R = 3.5 x 7.72 = 27 volts
Chambers
Maximum current required: 3.6 amperes (from step 2A)
Resistance: 7.72 ohms (from step 6A)
Voltage required, Equation 5: E = I x R = 3.6 x 1.25 = 4.5 volts
B) Downstream side
Maximum current required: 24.2 amperes (from step 2B)
Resistance: 0.63 ohms (from step 6B)
Voltage required, Equation 5: E = I x R = 24.2 x 0.63 = 15.3 volt
Selection of Rectifier

B-25
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
The largest design voltage requirement is 27 volts. Using a factor of safety of 120 percent,
rectifier voltage is calculated:
27 volts x (120%) = 33 volts
Total current required:
Upstream skin plate

= 3.50 amperes

Upstream chambers

= 7.1 amperes

Downstream chambers

= 24.2 amperes
34.8 amperes

For a commercially available rectifier having an output of 40 volts, 40 amperes is chosen.


Because of the different circuit resistances, separate control over each circuit is required. This is
best handled by a rectifier having 3 separate automatic constant current output circuits. Figure
B-6 shows the circuitry.

B-26
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04

FIGURE B-6. CIRCUIT DIAGRAM FOR LOCK MITER GATE

B-27
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Rod Anode Installation

Rod anodes can be supported by the cable from a clevis at the top of the gate. Since ice and
debris are expected, the anodes need to be protected. This is best done by installing them within
perforated polyethylene or fiberglass pipes. A steel half-pipe bumper is used outside the plastic
pipe. The anodes may be secured at the bottom using a stabilizing weight or stand off device.
Other Gate Applications

Anode configurations for a Cordell Hull tainter gate and a Cape Canaveral sector gate are shown
in Figures B-7 and B-8.

FIGURE B-7. TAINTER GATE DESIGN AT CORDELL HULL


SHOWING FLAT DISK ANODE PLACEMENT

B-28
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04

FIGURE B-8. SECTOR GATE DESIGN AT CAPE CANAVERAL


SHOWING FLAT DISK ANODE PLACEMENT

B-29
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
APPENDIX C
SACRIFICIAL CATHODIC PROTECTION SYSTEM BASIC DESIGN FORMULAE AND
REFERENCE TABLES FOR CIVIL WORKS APPLICATIONS
A study was performed to characterize the resistance and hence current output for the most
common shapes and sizes of sacrificial anodes. Multiple measurements were taken at remote
earth in waters with resistivity of 1250 ohm-cm and 4550 ohm-cm. The results are summarized
*
in Figure C-1. Table C-1 provides the average resistance values obtained on each of the two
anode types that were evaluated. The anode specimen numbers were developed to indicate the
dimensions of each anode, in in., with each dimension being separated by an x, followed by
the anode style (R for round and S for slab), and then the edge condition (BE for bare edge
and CE for coated edge). All anodes are coated on their back surfaces.

Resistance (Ohms)

0.03
0.025
y = 0.1469x -0.5482
R2 = 0.9806

0.02
0.015
0.01
0.005
0
0

100

200

300

400

Exposed Surface Area (Sq. In.)

FIGURE C-1. RESISTANCE VS ANODE SURFACE AREA


NORMALIZED FOR 1 OHM-CM RESISTIVITY WATER

Marsh, Charles P., and J. B. Bushman, Direct Determination of Galvanic Anode Current Output for Common Shapes Used In
Civil Works Applications, presented to the Tri-Service Corrosion Conference (21 November 2003, Las Vegas, NV).

C-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE C-1. CURRENT OUTPUT FOR RECOMMENDED ALLOYS OF
MAGNESIUM AND ZINC IN 1 OHM-CM RESISTIVITY WATER
Anode Style No.

Anode Type

2x5RBE
2x5RCE
1x6x12SBE
1x6x12SCE
2x8x8SBE
2x8x8SCE
2x6x12SBE
2x6x12SCE
2x9x18SBE
2x9x18SCE
4x9x18SBE
4x9x18SCE

Button
Button
Slab
Slab
Slab
Slab
Slab
Slab
Slab
Slab
Slab
Slab

Current output in 1
ohm-cm Water using
high-potential Mag
(milliamperes)

Current output in 1
ohm-cm Water using
H-1 Alloy Mag
(milliamperes)

Current output in 1
ohm-cm Water using
high-purity Zinc
(milliamperes)

55,882
33,101
84,070
67,375
92,233
63,333
98,958
67,376
139,706
105,556
166,667
105,556

41,176
24,390
61,947
49,645
67,961
46,667
72,917
49,645
102,941
77,778
122,807
77,778

14,706
8,711
22,124
17,731
24,272
16,667
26,042
17,731
36,765
27,778
43,860
27,778

The current output calculations in Table C-1 are based on the structure being protected to a
polarized potential of -0.85 volt with respect to a Cu-CuSO4 reference electrode. Further, the
values for each alloy are based on the most commonly used potential values for each alloy versus
Cu-CuSO4 reference electrode of -1.80 volts for high-potential alloy magnesium, -1.55 Volts for
H-1 alloy magnesium (Grade A or B only) and -1.1 Volts for high-purity Zinc.
Table C-2 provides the approximate weight of each anode style in both magnesium and zinc
alloys. Because the life of any galvanic anode is directly proportional to its weight and inversely
proportional to its current output, both values must be known to calculate anode life.
TABLE C-2. APPROXIMATE ANODE WEIGHT
High-Potential
And H-1 Alloy
Magesium Anode
Weight (Pounds)

High-Purity Zinc
Anode Weight
(Pounds)

Anode Style No.

Anode Type

2x5RBE

Button

2.5

2x5RCE

Button

2.5

10

1x6x12SBE

Slab

22

1x6x12SCE

Slab

22

2x8x8SBE

Slab

7.5

30

2x8x8SCE

Slab

7.5

30

2x6x12SBE

Slab

10

42

2x6x12SCE

Slab

10

42

2x9x18SBE

Slab

24

95

2x9x18SCE

Slab

24

95

4x9x18SBE

Slab

44

175

4x9x18SCE

Slab

44

175

C-2
More ebooks : http://artikel-software.com/blog

10

EM 1110-2-2704
12 Jul 04
Given the above information, the current output for any of the evaluated anode styles in different
electrochemical environments can be calculated using the following formula

Ia =

I alloy 1
P

where:
Ia = current output of anode in water surrounding structure to be protected
Ialloy1 = current output of anode metal alloy selected from Table 2 in 1 ohm-cm water (in
milliamperes)
P = measured resistivity of water surrounding structure to be protected
As an example, for a lock gate immersed in 2700 ohm-cm water, the current output using a
2x9x18SBE high-potential magnesium alloy anode would be:
139 , 706
2700

= 51.74mA

If H-1 magnesium alloy were used instead, the current output for this same style anode would be:
102 , 941
2700

= 38.13mA

If high-purity zinc alloy were used instead, the current output for this same style anode would be:
36 , 765
2700

= 13.62mA

Because the amount of bare submerged metal that can be protected is directly proportional to the
current output of the anode, it can be seen that the high-potential magnesium alloy can protect
1.36 times as much surface area as the H-1 magnesium alloy and 3.8 times as much surface area
as the high-purity zinc alloy.
Another consideration in anode selection is that the life of each anode is inversely proportional to
the current output of the anode. Two different formulae, one for magnesium-based alloys and
another for zinc-based alloys, are used for calculating anode service life. For magnesium-based
anodes, the following formula applies:

C-3
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04

Lifemag ( years ) =

116 W E UF
I

where:
Lifemag(years) = years before anode is consumed to the point where its size has been reduced
substantially by corrosion and its current output has reduced to the point where it is no longer
considered an effective anode.
W = weight of magnesium metal in anode
E = efficiency in converting corrosion current to cathodic protection current = 50% for
magnesium
UF = percentage anode used before it is no long considered an effective anode = normally
85% for any galvanic anode
I = current output of single anode in milliamperes
For the 2x9x18SBE high-potential magnesium alloy anode example given above, installed in
2700 ohm-cm resistivity water, the life of the anode would be:

Lifemag ( years ) =

116 24 0.5 0.85


51.74

Lifemag ( years ) = 22.9


For the same anode using H-1 alloy magnesium, the 2x9x18SBE style anode installed in 2700
ohm-cm resistivity water, the life of the anode would be:

Lifemag ( years ) =

116 24 0.5 0.85


38.13

Lifemag ( years ) = 31.0


As noted above, a slightly different formula is used for zinc anodes:

Lifezinc ( years ) =

42.4 W E UF
I

C-4
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Lifemag(years) = years before anode is consumed to the point where its size has been reduced
substantially by corrosion and its current output has reduced to the point where it is no longer
considered an effective anode.
W = weight of zinc metal in anode
E = efficiency in converting corrosion current to cathodic protection current = 90% for zinc
UF = percentage anode used before it is no long considered an effective anode = normally
85% for any galvanic anode
I = current output of single anode in milliamperes
Therefore, for the same anode using high-purity zinc alloy, the 2x9x18SBE style anode installed
in 2700 ohm-cm resistivity water, the life of the anode would be:

LifeZinc ( years ) =

42.4 95 0.9 0.85


13.62

LifeZinc ( years ) = 226


Given the anode lives calculated for each of the three examples, if a 20 year design life were
desired, the high-potential Alloy would not be acceptable in water of this resistivity while the H1 Alloy would have the desired life. The life of the high-purity zinc alloy anode in this style
would be considered excessive, and an alternative style would be considered if zinc were the
preferred anode material. However, as explained below, it should be noted that zinc anodes are
not recommended for use in water exceeding 2500 ohm-cm resistivity.
Because the anode efficiencies for zinc and magnesium are known to be 0.9 and 0.5, respectively,
and because a utilization factor of 0.85 is almost always applied by corrosion engineers in
designing systems, a simple graph of anode life versus current output can be made for
magnesium (Figure C-2) and zinc (Figure C-3) alloy anodes.

C-5
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Chart 2 - Magnesium Anode Life vs Current Output
50.00

Life (Years)

40.00

2x5R
1x6x12S
2x8x8S
2x6x12S
2x9x18S
4x9x18S

30.00

20.00

10.00

0.00
0

10

20

30

40

50

60

70

80

90

100

Current Output (mA)

FIGURE C-2. MAGNESIUM ANODE LIFE VERSUS CURRENT OUTPUT


Chart #3 - Zinc Anode Life vs Current Output
100.00
90.00
80.00
70.00
2x5R
1x6x12S
2x8x8S
2x6x12S
2x9x18S
4x9x18S

Years

60.00
50.00
40.00
30.00
20.00
10.00
0.00
0

20

40

60

80

100

120

140

160

180

200

Current Output (mA)

FIGURE C-3. ZINC ANODE LIFE VERSUS CURRENT OUTPUT


As can be seen from Figures C-2 and C-3, only one magnesium anode style has a 20-year life at
100 mA current output. By comparison, there are five zinc anode styles with a 20-year life at
100 mA and two at 200 mA. However, zinc is capable of delivering this higher current only in
very low-resistivity water (usually brackish or salt water).
In summary, magnesium is preferred in higher resistivity waters (above 2000 ohm-cm) while
zinc will almost always be preferred in waters below 1000 ohm-cm. For water above 3000 ohmcm, high-potential magnesium will generally be preferred, and from 1500 to 2000 ohm-cm, H-1
Alloy will almost always be preferred. Table C-3 will help in this general selection process.

C-6
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE C-3. PREFERRED ALLOYS FOR VARIOUS RESISTIVITY WATERS
(Best = 999)
Water
Resistivity
(Ohm-Cm)

< 500

>500 to
1000

>1000 to
1500

high-potential
Magnesium
H-1 Alloy, Grade
A or B
Magnesium
high-purity Zinc

999

99

>1500 to
2000

>2000 to
2500

>2500 to
3500

>3500

99

999

999

99

999

99

99

With respect to current output of each anode style, charts can be developed for specific resistivity
environments. Generally, fresh water river and lake water will have resistivity values between
1000 ohm-cm and 3000 ohm-cm. Tables C-4 C-9 list in detail the current output for each
anode style. These tables include a visual plot of the data for comparison purposes. The water
resistivity values used in these tables range from 1000 ohm-cm to 4000 ohm-cm, in increments
of 500 ohm-cm.

C-7
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE C-4. ANODE CURRENT OUTPUT
IN 1000 OHM-CM RESISTIVITY WATER
high-potential
Mag

H-1 Mag

high-purity Zinc

2x5RBE

55.88

41.18

14.71

2x5RCE

33.10

24.39

8.71

1x6x12SBE

84.07

61.95

22.12

1x6x12SCE

67.38

49.65

17.73

2x8x8SBE

92.23

67.96

24.27

2x8x8SCE

63.33

46.67

16.67

2x6x12SBE

98.96

72.92

26.04

2x6x12SCE

67.38

49.65

17.73

2x9x18SBE

139.7

102.9

36.77

2x9x18SCE

105.6

77.78

27.78

4x9x18SBE

166.7

122.8

43.86

4x9x18SCE

105.6

77.78

27.78

Anode Style

Anode Current Output in 1000 Ohm-Cm Water


160

HiPotential
Mag
H-1 Mag

140
120
100
80
60

Hi-Purity
Zinc

40
20
0

2x
5R
2x BE
1x 5R
6x C
E
1x 12S
6x B
1 E
2x 2SC
8x E
2x 8SB
8
E
2x x 8S
6x C
E
2x 12S
6x B
E
2x 12S
9x C
E
2x 18S
9x B
E
4x 18S
9x C
E
4x 18S
9x B
18 E
SC
E

Current Output (mA)

180

Anode Style No.

C-8
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE C-5. ANODE CURRENT OUTPUT
IN 1500 OHM-CM RESISTIVITY WATER
high-potential
Mag

H-1 Mag

high-purity Zinc

2x5RBE

37.25

27.45

9.80

2x5RCE

22.07

16.26

5.81

1x6x12SBE

56.05

41.30

14.75

1x6x12SCE

44.92

33.10

11.82

2x8x8SBE

61.49

45.31

16.18

2x8x8SCE

42.22

31.11

11.11

2x6x12SBE

65.97

48.61

17.36

2x6x12SCE

44.92

33.10

11.82

2x9x18SBE

93.14

68.63

24.51

2x9x18SCE

70.37

51.85

18.52

4x9x18SBE

111.1

81.87

29.24

4x9x18SCE

70.37

51.85

18.52

Anode Current Output in 1500 Ohm-Cm Water


HiPotential
Mag

100
80

H-1 Mag

60
40
20
Hi-Purity
Zinc

C
1x 12S E
6x B
1 E
2x 2S
8x CE
2x 8S
8 BE
2 x x 8S
6x C
E
2x 12S
6x B
E
2x 12S
9x C
2x 18S E
9x B
E
4x 18S
9x C
E
4x 18S
9x B
18 E
S
C
E

6x

5R

1x

2x

5R

2x

Current Output (mA

120

Anode Style No.

C-9
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE C-6. ANODE CURRENT OUTPUT
IN 2000 OHM-CM RESISTIVITY WATER
high-potential
Mag

H-1 Mag

high-purity Zinc*

2x5RBE

27.94

20.59

7.35

2x5RCE

16.55

12.20

4.36

1x6x12SBE

42.04

30.97

11.06

1x6x12SCE

33.69

24.82

8.87

2x8x8SBE

46.12

33.98

12.14

2x8x8SCE

31.67

23.33

8.33

2x6x12SBE

49.48

36.46

13.02

2x6x12SCE

33.69

24.82

8.87

2x9x18SBE

69.85

51.47

18.38

2x9x18SCE

52.78

38.89

13.89

4x9x18SBE

83.33

61.40

21.93

4x9x18SCE

52.78

38.89

13.89

90
80
70
60
50
40
30
20
10
0

HiPotential
Mag

H-1 Mag

Hi-Purity
Zinc

2x
5R
2x BE
1x 5R
6x C
E
1x 12S
6x B
12 E
2x SC
8x E
8
2x SB
8x E
2x 8S
6x C
1 E
2x 2S
6x BE
1
2x 2S
9x CE
2x 18S
9x B
1 E
4x 8S
9x CE
1
4x 8S
9x BE
18
S
C
E

Current Output (mA)

Anode Current Output in 2000 Ohm-Cm Water

Anode Style No.

* Use of zinc anodes in waters above 2000 ohm-cm is not recommended.

C-10
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE C-7. ANODE CURRENT OUTPUT
IN 2500 OHM-CM RESISTIVITY WATER
high-potential
Mag

H-1 Mag

high-purity Zinc*

2x5RBE

22.35

16.47

5.88

2x5RCE

13.24

9.76

3.48

1x6x12SBE

33.63

24.78

8.85

1x6x12SCE

26.95

19.86

7.09

2x8x8SBE

36.89

27.18

9.71

2x8x8SCE

25.33

18.67

6.67

2x6x12SBE

39.58

29.17

10.42

2x6x12SCE

26.95

19.86

7.09

2x9x18SBE

55.88

41.18

14.71

2x9x18SCE

42.22

31.11

11.11

4x9x18SBE

66.67

49.12

17.54

4x9x18SCE

42.22

31.11

11.11

Anode Current Output in 2500 Ohm-Cm Water

Current Output (mA)

70

50

HiPotential
Mag

40

H-1 Mag

60

30
20

Hi-Purity
Zinc

10

2x
5R
2x BE
1x 5R
6x C
1x 12S E
6x B
1 E
2x 2SC
8x E
2x 8SB
8
E
2x x8S
6x C
E
2x 12S
6x B
E
2x 12S
9x C
E
2x 18S
9x B
E
4x 18S
9x C
E
4x 18S
9x B
18 E
S
C
E

Anode Style No.

* Use of zinc anodes in waters above 2000 ohm-cm is not recommended.

C-11
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE C-8. ANODE CURRENT OUTPUT
IN 3000 OHM-CM RESISTIVITY WATER
high-potential
Mag

H-1 Mag

high-purity Zinc*

2x5RBE

18.63

13.73

4.90

2x5RCE

11.03

8.13

2.90

1x6x12SBE

28.02

20.65

7.37

1x6x12SCE

22.46

16.55

5.91

2x8x8SBE

30.74

22.65

8.09

2x8x8SCE

21.11

15.56

5.56

2x6x12SBE

32.99

24.31

8.68

2x6x12SCE

22.46

16.55

5.91

2x9x18SBE

46.57

34.31

12.26

2x9x18SCE

35.19

25.93

9.26

4x9x18SBE

55.56

40.94

14.62

4x9x18SCE

35.19

25.93

9.26

Anode Current Output in 3000 Ohm-Cm Water

Current Output (mA)

60
50
40

HiPotential
Mag

30

H-1
Mag

20

Hi-Purity
Zinc

10

2x
5R
2x BE
1x 5R
6x CE
1
1x 2S
6x BE
12
2x SC
8x E
8
2x SB
8x E
2x 8S
6x CE
1
2x 2S
6x BE
1
2x 2S
9x CE
1
2x 8S
9x BE
1
4x 8S
9x CE
1
4x 8S
9x BE
18
SC
E

Anode Style No.

* Use of zinc anodes in waters above 2000 ohm-cm is not recommended.

C-12
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE C-9. ANODE CURRENT OUTPUT
IN 3500 OHM-CM RESISTIVITY WATER
high-potential
Mag

H-1 Mag

high-purity Zinc*

2x5RBE

15.97

11.76

4.20

2x5RCE

9.46

6.97

2.49

1x6x12SBE

24.02

17.70

6.32

1x6x12SCE

19.25

14.18

5.07

2x8x8SBE

26.35

19.42

6.93

2x8x8SCE

18.10

13.33

4.76

2x6x12SBE

28.27

20.83

7.44

2x6x12SCE

19.25

14.18

5.07

2x9x18SBE

39.92

29.41

10.50

2x9x18SCE

30.16

22.22

7.94

4x9x18SBE

47.62

35.09

12.53

4x9x18SCE

30.16

22.22

7.94

Anode Current Output in 3500 Ohm-Cm Water


50

Current Output (mA)

45
40

HiPotential
Mag

35
30
25

H-1 Mag

20
15

Hi-Purity
Zinc

10
5

2x
5

RB
2x E
5R
1x
6x C E
12
1x S B
E
6x
12
S
C
2x
8x E
8S
B
2x
8x E
8S
2x
C
E
6x
12
2x S B
6x
E
12
2x S C
9x
E
18
2x S B
E
9x
18
4x S C
9x
E
18
4x S B
9x
E
18
SC
E

Anode Style No.

* Use of zinc anodes in waters above 2000 ohm-cm is not recommended.

C-13
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE C-10. ANODE CURRENT OUTPUT
IN 4000 OHM-CM RESISTIVITY WATER
high-potential
Mag

H-1 Mag

high-purity Zinc*

2x5RBE

13.97

10.29

3.68

2x5RCE

8.28

6.10

2.18

1x6x12SBE

21.02

15.49

5.53

1x6x12SCE

16.84

12.41

4.43

2x8x8SBE

23.06

16.99

6.07

2x8x8SCE

15.83

11.67

4.17

2x6x12SBE

24.74

18.23

6.51

2x6x12SCE

16.84

12.41

4.43

2x9x18SBE

34.93

25.74

9.19

2x9x18SCE

26.39

19.44

6.94

4x9x18SBE

41.67

30.70

10.97

4x9x18SCE

26.39

19.44

6.94

Anode Current Output in 4000 Ohm-Cm Water


50

Current Output (mA)

45
35

HiPotential
Mag

30

H-1 Mag

40

25
20
Hi-Purity
Zinc

15
10
5

2x
5R
B
2x E
5R
1x
C
E
6x
12
S
1x
BE
6x
12
SC
2x
8x E
8S
BE
2x
8x
8S
2x
C
E
6x
12
SB
2x
E
6x
12
SC
2x
E
9x
18
S
2x
BE
9x
18
SC
4x
E
9x
18
S
4x
BE
9x
18
SC
E

Anode Style No.

* Use of zinc anodes in waters above 2000 ohm-cm is not recommended.

C-14
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
APPENDIX D
DETAILED GALVANIC CATHODIC PROTECTION DESIGN EXAMPLE BASED ON PIKE
ISLAND AUXILIARY LOCK GATES USING SLAB ANODES
D-1. Design for Lock Gates
Figure D-1 shows a Pike Island auxiliary miter gate. This gate is approximately 18.85 m (62 ft)
long and 10.64 m (35 ft) high. With the river at normal water level, portions of each gate will
always be submerged, and other portions may be submerged or exposed as lockages occur.
During times of high water, more gate surfaces will be submerged, and, under conditions of
flood, the entire gates may be submerged. The usual water depth is 9.12 m (30 ft).
K

J
I

HWL

Downstream Side

Quoin
End

MIter
End

HWL

Upstream Side

Miter
End

Quoin
End

FIGURE D-1. LOCK GATE VERTICAL, DOWNSTREAM


AND UPSTREAM STRUCTURAL LAYOUT
The gates are constructed of welded structural steel, horizontally framed, with a cast pintle. The
downstream side of the gate consists of a pattern of rectangular chambers closed on five faces
and open to the water on the sixth face. The upstream face of the gate consists of a large skin
D-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
plate (area K on sketch) over the major portion of the face and two columns of small chambers
(chambers M, L, J & I) at the quoin and miter ends of the gate.
The main (large) chambers (chambers C, D, E, and F) on the downstream face of the gate are set
in four columns and are approximately 3.66 m (12 ft) wide, varying in height from 1.01 m (3 ft 4
in.) to 1.82 m (6 ft), with a depth of 1.06 m (3 ft 6 in.). The two sets of vertically aligned
chambers, at the quoin and miter ends of the gates (chambers A, B, G, & H), are much smaller
and irregularly shaped. There are six horizontally aligned rows of chambers placed one above
the other in each vertical column, giving a total of 48 chambers on the downstream side,
however, only the five lower chambers are normally submerged.
D-2. Design Data
The following information, with values and assumptions included here for the current example,
must be known in order to design any CPS for a Lock Gate Structure:
a. The lock is located in fresh water with a resistivity of 1900 ohm-centimeters. Note:
This information must be measured either on-site or from sample of water obtained on-site.
Either should be obtained when water is at its highest resistivity (usually in fall when rainfall is
least and run-off is least).
b. Water velocity is less than 1524 mm/s (5 ft/s).
c. Water contains debris, and icing will occur in the winter.
d. The gate surfaces have a new vinyl paint coating, minimum of 0.15 mm (6 mils) thick,
with not more than 1 percent of the area bare because of holidays in the coating.
e. The coating will deteriorate during 20 years of exposure. Based on the recent
experience with the coating systems being applied to modern structures, it is reasonable and
conservative to assume that 15 percent of the area will become bare in 20 years.
f. Design for 75.35 mA/m2 (7.0 mA/ft2) (moving fresh water).
g. Design for a 20-year life.
h. Design for normally submerged surface areas.
i. For galvanic anode systems, the anodes required must be based on the maximum (final)
current requirement over the anode design life since the system has no adjustment capability.

D-2
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
D-3. Computations
a. Find the Surface Area to be Protected
(1) Upstream Side
i.
Area of skin plate K: While the gate has an overall height of 10.64 m, it is normally
submerged to a depth of 9.14 feet. The width of the gate covered by the skin plate is measured to
be 14.50 m. Therefore, the submerged surface area of the skin plate = 14.50 m x 9.14 m =
132.53 m2 (1,427 ft2).
ii. Larger chamber areas J & L adjacent to skin plate: 5 each larger normally
submerged chambers adjacent to skin plate each having 6.50 m2 (70 ft2) surface area. Note: the
sixth chamber at top of each column of chambers is normally above the high-water line and will
not be provided with protection.
iii. Smaller chambers I & M adjacent to quoin and miter end: five each smaller,
normally submerged chambers adjacent to skin plate each having 3.7 m2 (40 ft2) surface area.
Note: the sixth chamber at top of each column of chambers is normally above the high water line
and will not be provided with protection.
(2) Downstream Side
i.
Large chambers C, D, E, & F: With five normally submerged chamber stacked in
four columns, there are a total of 20 chambers. Note that the sixth chamber at top of each
column of chambers is normally above the high-water line and will not be provided with
protection. While their height varies slightly, the design will be based on the large chamber with
greatest height (which has the largest surface area). The dimensions for the largest of these
chambers is 3.66 m (12 ft) wide, 1.82 m (6 ft) high 1.06 m (3.5 ft) deep. Based on this
information, the individual submerged area of chambers C, D, E, and F = area of both ends of the
chambers + area of top and both of each chamber + area of back of chamber = (2 x 1.06 x 1.82)
+ (2 x 1.06 x 3.66) + (1.82 x 3.66) = 3.85 + 7.76 + 6.66 = 18.87 m2 (203.2 ft2).
ii. Small chambers A, B, G & H: With five normally submerged chambers stacked in
four columns, there are a total of 20 chambers. Again, note that the sixth chamber at top of each
column of chambers is normally above the high-water line and will not be provided with
protection. The smallest chambers (A and H) have the same width of 0.9 meters each with an
average depth of 0.2 meters while the two larger chambers (B and G) have a width of 1.1 meters
each and an average depth of 0.4 meters. Each chamber will be designed on the chamber having
the greatest height of 1.82 m. Thus the area of the smallest chambers A and H = (2 x 0.2 x 1.82)
+ (2 x 0.2 x 0.9) + (1.82 x 0.9) = 0.78+ 0.36 + 1.64 = 2.78 m2 (30 ft2). The area of the next

D-3
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
smallest chambers B & G = (2 x 0.4 x 1.82) + (2 x 0.4 x 1.1) + (1.82 x 1.1) = 1.46+ 0.88 + 2.0 =
2
2
4.34 m (46.7 ft ).
(3) Create a Summary Table of Area for Each Chamber (Table D-1)
TABLE D-1. CHAMBER AREA VALUES
Chamber or
Surface ID

Side of Gate

Type of
Area

No. Submerged

Area Each
2
2
m (ft )

Area Total
m2 (ft2)

A&H

Downstream

Chamber

5 x 2 = 10

2.78 (30)

27.8 (300)

B&G

Downstream

Chamber

5 x 2 = 10

4.34 (46.7)

43.4 (467)

C, D, E, & F

Downstream

Chamber

5 x 2 = 10

18.9 (203)

189 (2030)

I&M

Upstream

Chamber

5 x 2 = 10

3.7 (40)

37 (400)

J&L

Upstream

Chamber

5 x 2 = 10

6.50 (70)

65.0 (700)

Upstream

Skin Plate

133 (1,427)

133 (1,427)

Total Submerged Area

495.2 (5,324)

b. Calculate the Current Required for a Single Structure Component


I = A x I'(1.0 - CE)

[EQ 1]

where:
A = surface area to be protected
I' = required current density per bare ft2 of steel submerged to adequately protect gate =
75.35 mA/m2 = 7 mA/ft2
CE = coating efficiency (0.85 at end of 20 years service)
Example calculation only for skin plate requirement: I = 133 m2 x 75.35 mA/m2 x (1
0.85) = 1503 mA

D-4
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
c. Create a Table of Current Requirements for Each Structure Component (Table D-2)
TABLE D-2. CURRENT REQUIREMENTS FOR EACH STRUCTURE COMPONENT
Chamber or
Surface ID

Area
Each
m2

Current
Density I'
(mA/m2)

1 - CE

Min. No.
Anodes*

Current
Required per
Unit (mA)

Current Required for


All Units (mA)

Chamber

2.78

75.35

.15

31.4

314.2

Chamber

4.34

75.35

.15

49.1

490.5

Chamber

18.9

75.35

.15

213.6

2136.0

Side of Gate

Type of
Area

A&H

Downstream

B&G

Downstream

C, D, E, F

Downstream

I&M

Upstream

Chamber

3.7

75.35

.15

41.8

418.2

J&L

Upstream

Chamber

6.50

75.35

.15

73.5

734.7

Upstream

Skin Plate

133

75.35

.15

14

1503.2

1503.2

Total Current Required

5596.8

* To ensure uniform current distribution, it is normally good design practice to provide at least 1 galvanic anode per 10 m

structure

surface to be protected.

d. Select Anode Alloy


Refer to Table C-3 in Appendix C. Because the water resistivity is approximately 1900 ohm-cm,
it is apparent that the preferred anode alloy material, considering both the current output
available and anode life, is H-1 magnesium alloy (Grade A or B). If none of the available shapes
provide sufficient current, re-evaluate using high-potential magnesium alloy anodes. If anode
life proves too short with both magnesium alloys, then high-purity zinc alloy anodes should be
considered.
e. Select Anode Size
Size is governed by the amount of current required for each size chamber and the skin plate.
Because there are multiple chamber sizes to consider, start with the smallest surface and then
sequentially evaluate the larger chambers. Designing the smaller components is simpler and will
familiarize the designer with the process.
(1) Chambers A and H
i.

Current Required per unit = 31.4 mA

ii. Initial Anode Selection: Refer to Tables C-4 through C-10 in Appendix C. Select the
table with the resistivity closest to that of the measured water resistivity. In this case, the water
resistivity is 1900 ohm-cm, so the appropriate reference would be Table C-6, Appendix C, for
2000 ohm-cm resistivity water. The bar chart included in Table C-6 provides a visual aid to help
quickly determine which anodes may be appropriate for this chamber. Based on Table C-6, the

D-5
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
1x6x12SBE, 2x8x8SBE, 2x9x18SCE, and 4x9x18SCE anode sizes appear to be the most
appropriate.
iii. Anode Selection Based On Life: The desired anode life is 20 years. Using Figure C2, Appendix C, only the 2x9x18 or 4x9x18 shapes have sufficient metal weight to meet the 20year service life requirement at the 31.4 mA output desired. Because the 2x9x18SCE has
sufficient life and will provide the desired current for this chamber, install one 2x9x18SCE
plastisol-coated H-1 Alloy Grade A or B magnesium alloy anode for the 10 A and H Chambers.
Also check and note that one anode per chamber is sufficient for good current distribution in
these chambers (see Table D-2).
(2) Chambers B and G
i.

Current Required per unit = 49.1 mA

ii. Initial Anode Selection: Again refer to Tables C-4 through C-10 in Appendix C.
Select the table with the resistivity closest to that of the measured water resistivity. As before,
the water resistivity is 1900 ohm-cm, so the appropriate reference is Table C-6, Appendix C.
Again, based on the data and bar chart visual aid, the only anodes to be considered are the
2x9x18SBE and the 4x9x18SBE.
iii. Anode Selection Based On Life: The desired anode life is 20 years. Using Figure C2, Appendix C, only the 2x9x18 or 4x9x18 shapes have sufficient metal weight to meet the 20year life requirement at the 49.1 mA output desired. Again, because the 2x9x18SBE has
sufficient life and will provide the desired current for this chamber, install one 2x9x18SBE, H-1
Alloy, Grade A or B magnesium alloy anode with bare sides and face for the 10 B and G
Chambers. Also check and note that one anode per chamber is sufficient for good current
distribution in these chambers (see Table D-2).
(3) Chambers C, D, E, and F
i.

Current Required per unit = 213.6 mA

ii. Initial Anode Selection: Again refer to Tables C-4 through C-10 in Appendix C.
Select the table with the resistivity closest to that of the measured water resistivity. As before,
the water resistivity is 1900 ohm-cm, so the appropriate reference is Table C-6, Appendix C.
Based on the information gained from the designs for the previous smaller chambers, no single
anode will be able to meet the current requirement for these large chambers. Instead, it would be
preferable to use the least number of H-1 alloy magnesium anodes that will provide the desired
current of 213.6 mA. Table C-6 shows that the 4x8x18SBE H-1 alloy magnesium anodes
provides the highest current output of 64 mA. Four anodes of this model will provide 256 mA,
which is sufficient to meet the design requirement. Also note that the 2x9x18SBE H-1 alloy
D-6
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
magnesium anode provides a current output of 53 mA. Four anodes of this model will provide
212 mA, which is extremely close to the design current requirement. Both anodes may be
considered, however, because the water resistivity is slightly lower than the 2000 ohm-cm value
used in Table C-6. Therefore, both anodes (with four per chamber) would in fact meet the
desired current requirement.
iii. Anode Selection Based On Life: As before, the desired anode service life is 20 years.
Figure C-2 shows that only the 2x9x18 shape has sufficient magnesium metal weight to meet the
20-year service life requirement at the desired 53 mA/anode output. Thus, install four
2x9x18SBE, H-1, Grade A or B Alloy, magnesium anodes with bare sides and face for the 40 C,
D, E, and F Chambers. It should be noted that the four anodes per chamber exceeds the
minimum number of two anodes required for good current distribution (see Table D-2).
(4) Chambers I and M
i.

Current Required per unit = 41.8 mA

ii. Initial Anode Selection: Again refer to Tables C-4 through C-10 in Appendix C.
Select the table with the resistivity closest to that of the measured water resistivity. As before,
the water resistivity is 1900 ohm-cm, so the appropriate reference is Table C-6, Appendix C.
Based on the data and bar chart visual aid, the only anodes to be considered are the 2x9x18SBE
and the 4x9x18SBE.
iii. Anode Selection Based On Life: The desired anode life is 20 years. Using Figure C2, Appendix C, only the 2x9x18 or 4x9x18 shapes have sufficient metal weight to meet the 20year life at the 41.8 mA output desired. Because the 2x9x18SBE has sufficient life and will
provide the desired current for this chamber, install one 2x9x18SBE H-1 Alloy Grade A or B
magnesium alloy anode with bare sides and face for the 10 I and M Chambers. Also check and
note that one anode per chamber is sufficient for good current distribution in these chambers (see
Table D-2).
(5) Chambers J and L
i.

Current Required per unit = 73.5 mA

ii. Initial Anode Selection: Again refer to Tables C-4 through C-10 in Appendix C.
Select the table with the resistivity closest to that of the measured water resistivity. As before,
the water resistivity is 1900 ohm-cm, so the appropriate reference is Table C-6, Appendix C.
Based on the data and bar chart visual aid, it can be seen that none of the H-1 alloy magnesium
anodes will provide the desired current. However, high-potential alloy magnesium anodes in
configuration 2x9x18SBE provide 72 mA, which is very close to the calculated current, while the
4x9x18SBE will provide more than enough at 87 mA.
D-7
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
iii. Anode Selection Based On Life: Again the desired service life is 20 years. Figure C2, Appendix C, shows that only the 4x9x18 shape has sufficient metal weight to meet the 20-year
service life requirement at the 73.5 mA output desired. Thus, install one 4x9x18SBE highpotential alloy magnesium anode with bare sides and face for the 10 J and L Chambers. Also
check and note that one anode per chamber is sufficient for good current distribution in these
chambers (see Table D-2).
(6) Surface K (Skin Plate)
i.

Current Required = 1503.2 mA

ii.

Initial Anode Selection:

(a) Again refer to Tables C-4 through C-10 in Appendix C. Select the table with the
resistivity closest to that of the measured water resistivity. As before, the water resistivity is
1900 ohm-cm, so the appropriate reference is Table C-6, Appendix C. Based on the information
gained from the designs for the previous smaller chambers, no single anode will be able to meet
the current requirement for these large chambers. Instead, it would be preferable to use the least
number of H-1 alloy magnesium anodes that will provide the desired current of 1503.2 mA.
Table C-6 indicates that the 4x8x18SBE H-1 alloy magnesium anode provides the highest current
output, 64 mA, while the 2x9x18SBE H-1 alloy magnesium anode provides current output of 53
mA. Note that the 2x9x18SCE high-potential alloy magnesium anode also will output 50 mA.
Any one of these three anodes could be used, but the 4 in. thick H-1 alloy anode will cost almost
twice as much as the 2 in. thick anode cast from the same alloy at the same width and length.
(b) An important consideration in anode selection for the Skin Plate is the value of
Plastisol coating of the anode. Although the coating restricts current flow from the anode to the
Skin Plate it in fact improves current distribution because the current from the sides of the anode
cannot flow to the steel directly adjacent to the anode. With bare edge anodes it is necessary to
place a neoprene rubber shield behind the anode to extend beyond the anode perimeter at least 2
in. This shield must be glued in place, typically with 100% silicon caulk. Unfortunately, this
shielding material can be damaged by debris or ice floating down the river and impacting
primarily on the exposed skin plate anodes. Consequently, for Skin Plate anodes only, if floating
debris or ice are expected in the application, it is normally recommended that the entire anode be
coated with Plastisol from which a window is cut to expose a limited operating surface. In the
current example, for the skin plate galvanic anode system, use 30 2x9x18SCE high-potential
Alloy plastisol-coated magnesium anodes. These will provide 1500 mA of current, which is
extremely close to the design current requirement. Both anodes may be considered because the
water resistivity is slightly lower than the values for charts 2000 ohm-cm resistivity given in
Table C-6, so 30 anodes will in fact meet the desired current requirement.

D-8
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
iii. Anode Selection Based On Life: The desired anode life is 20 years. Figure C-2
indicates that only the 2x9x18 shape has sufficient magnesium metal weight to meet the 20-year
service life requirement at the 50 mA/anode output desired. Thus, install 30 2x9x18SCE highpotential Alloy, Plastisol-coated magnesium anodes with coated back and sides to protect the
skin plate. It should be noted that the 30 anodes exceeds the minimum number of 1four anodes
required for good current distribution (see Table D-2).
f. Develop Anode Locations for Each Structure Element
Placement of anodes is simply a geometric process of distributing the anodes uniformly on each
protected structural element to achieve good current distribution.
(1) Chambers A, B, G, H, I, J, L, and M
In this example, locating of the anodes in the chamber requiring only one anode is simple in that
the anode will be placed on the back surface of each chamber, centered both vertically and
horizontally.
(2) Chambers C, D, E, and F
Where more than one anode is required in each chamber, the anodes will be centered vertically
within the chamber, but they must be evenly distributed along the side and back panels of the
chamber to achieve uniform current distribution. This is done by folding open the three-sided
box representing the anode into a flat rectangle, then mathematically distributing the anodes
horizontally within that rectangle. The only chambers in this example requiring multiple anodes
are the 20 large chambers whose depth is 1 meter and width is 3.7 meters. Because there are four
anodes to be distributed around the vertical perimeter surface of the chamber, the overall
perimeter dimension of 5.7 meters is first divided by the number of anodes, i.e, four in this case
(5.7 m/4 = 1.43 m). This value is used for the center-to-center (c-c) spacing of the four anodes.
Then divide the c-c value by 2 to arrive at the setback distance from the front edge of the
chamber for the two outermost anodes (1.43 m/2 = 0.71 m). Because the height of the chambers
varies from 1 m to 1.8 m, the vertical center point location of the anodes is shown as one-half of
the chamber height. The locations for the anodes in the large chambers is shown in Figure D-1).

D-9
More ebooks : http://artikel-software.com/blog

1m

EM 1110-2-2704
12 Jul 04

3.7 m

1/2 of
Chamber
Height

5.7 m

1.43 m

0.7 m

1.43 m

1.43 m

0.7 m

FIGURE D-1. GALVANIC SLAB ANODE LOCATIONS


IN LARGEST DOWNSTREAM GATE CHAMBERS
(3) Skin Plate
Because the Skin Plate will usually require multiple anodes distributed uniformly both vertically
and horizontally, the design procedure is somewhat different than it is for the chamber anode
configuration. In this case, use the total square footage of the submerged skin plate surface (133
m2) and divide by the number of anodes required to protect the skin plate (30 anodes) = 133
m2/30 anodes = 4.43 m2/anode. The width and height dimensions of each square area to be
protected by each anode is the square root of that area. To calculate the width and height of the
area to be protected by each anode, use the following formula:

W A1 = H A1 =

A A1

where:
WA1 = width of area protected by one anode
HA1 = height of area to be protected by one anode
AA1 = area to be protected by one anode
For this particular skin plate, the height and width of the area to be protected by each anode is
calculated below:
D-10
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04

W A1 = H

A1

4 . 43 = 2 . 1 meters

The number of anodes in each row across the skin plate is calculated by dividing the width of the
skin plate by the width of the area to be protected by a single anode. In this design, the skin plate
width is 14.50 meters and the single anode area width is 2.1 meters, or 14.50/2.1 = 6.9 anodes.
The number of anodes in each column across the skin plate is calculated by dividing the
submerged height of the skin plate by the height of the rectangular area to be protected by a
single anode. In this design, the skin plate submerged height is 9.12 meters and the single anode
area height is 2.1 meters, or 9.12/2.1 = 4.32 anodes.
To complete the calculation, round up both values to the next whole number. In this example, 6.9
becomes seven anodes equally spaced across the skin plate, and 4.32 becomes five anodes spaced
equally down from the normal high-water line to the bottom of the skin plate. As in the case of
the large chamber anodes, the horizontal spacing of the anodes is determined simply by dividing
the number of seven horizontally spaced anodes (in this case) into the skin plate width of 14.5
meters = 14.5/7 = 2.071 meters. The vertical spacing of the anodes is determined simply by
dividing the number of five vertically spaced anodes (in this case) into the skin plate submerged
height of 9.12 meters = 14.5/7 = 1.824 meters.
The layout for these anodes on the skin plate is shown in Figure D-2.

FIGURE D-2. EXAMPLE SLAB ANODE LAYOUT FOR UPSTREAM SIDE (SKIN PLATE)

D-11
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
APPENDIX E
DETAILED GALVANIC CATHODIC PROTECTION DESIGN EXAMPLE BASED ON PIKE
ISLAND AUXILIARY LOCK GATES USING ROD AND BAR ANODES
E-1. Overview of Elongated Rod and Bar Galvanic Anodes for Civil Works Structures
While the slab and disk galvanic anodes previously described in this manual are generally
preferred for civil works structures due to their inherent ruggedness and ease of installation,
occasionally the elongated shape of the anodes described in this section may provide design
solutions for some structures in higher resistivity environments. Their elongated shape may
provide better current distribution in some structure configurations and will usually deliver
higher current output for the same weight of material. On the other hand, for magnesium anodes,
this higher current output will result in reduced anode life. For example, a 2 in. diameter
magnesium rod anode 10 ft long installed in 1000 ohm-cm water will generate 334 milliamperes
DC current output but the life of the anode will only be 3.69 years. Thus, magnesium rod anodes
are normally only used in waters with resistivities in excess of 2000 ohm-cm (see Table C-3 in
Appendix C).
a. Extruded Magnesium Rod Anodes
High-potential magnesium anode rods are extruded in various diameters ranging from 0.5 2.562
in. (Figure E-1). Only the 2.5 in. and 2 in. diameters (the two cross sections at left in Figure E-1)
are typically used on civil works structures because these are the only sizes made with an 1/8 in.
galvanized steel core wire. All smaller diameters have a 1/16 in. or smaller diameter core wire,
which is not strong enough to suspend the anodes on civil works structures. These anodes are
intended for vertical mounting only since the core wire is not strong enough to support the anode
horizontally. Properties of the 2.5 in. and 2 in. rods are summarized in Table E-1.

E-1
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04

FIGURE E-1. DC-6722, DC-2375 (LEFT) AND OTHER EXTRUDED MAGNESIUM ANODE
CROSS SECTIONS SHOWING GALVANIZED STEEL CORE WIRE AT CENTER

TABLE E-1. EXTRUDED MAGNESIUM ROD ANODES


SUITABLE FOR CIVIL WORKS STRUCTURES
Shape
identification
number

Diameter,
inches

Approx.
Weight
(lb/linear ft)

Core wire
diameter, in.

Current Output I (mA) in


1000 Ohm-Cm Water per
Anode Length L
(inches)

DC-2375

2.024

2.5

0.188

I = 8.3L0.7737

DC-6722

2.562

4.0

0.188

I = 9.16L0.7623

The formulas for calculating current output of magnesium rod anodes 12 240 in. long in 1000
ohm-cm resistivity water were developed using Dwights equation and Ohms law, as shown in
Tables E-2 and E-3. These tables list input variables, current output, and service life calculations
for 2 in. and 2.5 in. diameter bare magnesium rods, respectively, using a calculating Microsoft

Excel spreadsheet.
The data from Tables E-2 and E-3 were used to generate graphs of current output versus anode
length for both diameters, which are shown in Figures E-2 and E-3. The Excel trend line
development function was then used to generate a curve of best fit using the power extrapolation
method. The coefficient of determination for extrapolation was in excess of 99.5% for both
curves.

E-2
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE E-2. MAGNESIUM ANODE RESISTANCE CURRENT
OUTPUT AND LIFE CALCULATIONS FOR 2 IN. DIAMETER BARE ROD
Variables
Soil Resistivity
Anode Metal
Anode Alloy
Anode Model No.

Value

Term

1000

Ohm-Cm

Mg
High-Potential
DC-2375

Anode Weight/Foot

2.5

Pounds

Anode Faradaic Consumption Rate

8.5

Lb/Amp-Yr.

Anode Efficiency (Percent used to provide CP Current)

50.0%

% Eff.

Utilization Factor

85.0%

UF

Anode Potential (vs. Cu-CuSO4)

1.75

Volts

Desired Cathode Potential (mV vs. Cu-CuSO4)

0.85

Volts

Net Anode-to-Structure Driving Potential


Anode Diameter

Length of 2 in. Diameter High-Potential


Magnesium Rod Anode (in.)

0.90

Volts

Inches

Package
Resistance (Ohms)

Total Current Output


in 1000 Ohm-Cm
Resistivity Water(mA)

Mag Anode Life


(Years)

12

14.9590

60

24

9.2851

97

2.54

36

6.8942

131

2.82

48

5.5454

162

3.04

60

4.6688

193

3.19

72

4.0490

222

3.33

84

3.5853

251

3.44

96

3.2241

279

3.53

108

2.9341

307

3.61

120

2.6955

334

3.69

132

2.4956

361

3.76

144

2.3254

387

3.82

156

2.1786

413

3.88

168

2.0506

439

3.93

180

1.9379

464

3.98

192

1.8378

490

4.02

204

1.7482

515

4.07

216

1.6677

540

4.11

228

1.5947

564

4.15

240

1.5283

589

4.19

E-3
More ebooks : http://artikel-software.com/blog

2.05

EM 1110-2-2704
12 Jul 04
TABLE E-3. MAGNESIUM ANODE RESISTANCE CURRENT
OUTPUT AND LIFE CALCULATIONS FOR 2.5 IN. DIAMETER BARE ROD
Variables
Soil Resistivity
Anode Metal
Anode Alloy
Anode Model No.

Value

Term

1000

Ohm-Cm

Mg
High-Potential
DC-6722

Anode Weight/Foot

4.0

Pounds

Anode Faradaic Consumption Rate

8.5

Lb/Amp-Yr.

Anode Efficiency (Percent used to provide CP Current)

50.0%

% Eff.

Utilization Factor

85.0%

UF

Anode Potential (vs. Cu-CuSO4)

1.75

Volts

Desired Cathode Potential (mV vs. Cu-CuSO4)

0.85

Volts

Net Anode-to-Structure Driving Potential

0.90

Volts

2.5

Inches

Package
Resistance (Ohms)

Total Current Output


(mA)

Mag Anode Life


(Years)

12

13.7964

65

3.03

24

8.7038

103

3.83

36

6.5067

138

4.29

48

5.2547

171

4.61

60

4.4363

203

4.86

72

3.8552

233

5.08

84

3.4192

263

5.25

96

3.0788

292

5.4

108

2.8049

321

5.53

120

2.5793

349

5.65

132

2.3899

377

5.75

144

2.2286

404

5.86

156

2.0892

431

5.95

168

1.9676

457

6.04

180

1.8604

484

6.11

192

1.7651

510

6.19

204

1.6798

536

6.25

216

1.6031

561

6.33

228

1.5335

587

6.38

240

1.4702

612

6.44

Anode Diameter

Length of 2.5 in. Diameter High-Potential


Magnesium Rod Anode (in.)

E-4
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04

Current Output (mA DC)

2" Dia. Extruded High Potential Magnesium Rod Anode Current


Output vs Anode Length - 1000 Ohm-Cm Resistivity Water
650
600
550
500
450
400
350
300
250
200
150
100
50
0

y = 8.3001x0.7737
R2 = 0.9991

Series1
Power (Series1)

24

48

72

96

120

144

168

192

216

240

Length (inches)

FIGURE E-2. CURRENT OUTPUT VERSUS ANODE LENGTH FOR


2 IN. DIAMETER HIGH-POTENTIAL MAGNESIUM ROD ANODES.
2.5" Dia. Extruded High Potential Magnesium Rod Anode Current
Output vs Anode Length - 1000 Ohm-Cm Resistivity Water

Current Output (mA DC)

700
y = 9.1631x0.7623
R2 = 0.9988

600
500
400

Series1
Power (Series1)

300
200
100
0
0

24

48

72

96

120

144

168

192

216

240

Length (inches)

FIGURE E-3. CURRENT OUTPUT VERSUS ANODE LENGTH FOR


2.5 IN. DIAMETER HIGH-POTENTIAL MAGNESIUM ROD ANODES.
For any magnesium anode to provide protection, a positive electrical connection must be
established and maintained between the anode and the structure being protected. The standard

E-5
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
end configurations used on civil works structures are 3 6 in. x 1/8 in. threaded core extended
one end only. This threaded rod can then be used to suspend the rod vertically from a suitable
support bracket. Generally, this connection is made by threading a standard galvanized steel nut
and washer on the rod (Figure E-4) and then inserting the rod up through a support bracket
(minimum 1/4 in. thick) or suitable plate on the structure. The wire core should be extended at
least 6 in. so the anode material is at least 5 in. from the metal mounting bracket or structure
surface to assure good anode current distribution. A galvanized steel star washer followed by a
standard washer and nylon insert lock nut are then used to fasten the rod in position. The star
washer improves the electrical contact to the structure. The entire connection must be properly
coated to prevent corrosion of the connection.

FIGURE E-4. MAGNESIUM ROD ANODE SHOWING


THREADED CORE WIRE, DOUBLE NUTS, AND WASHERS
b. High-Purity Cast Zinc Rods
Zinc rod anodes suitable for use on civil works structures are cast in molds around their core rod.
They are usually only practical for use in waters with resistivities from 100 to 2000 ohm-cm.
Waters with higher resistivities will provide relatively low current to the protected structure
although providing a theoretical service life well in excess of 100 years. In waters below 100
ohm-cm these anodes will have a service life of less than 10 years. In terms of material
properties, this anode is inherently more rugged and impact-resistant than the extruded
magnesium rod anode. The most commonly used shape has either a 2 in. or 2.5 in. square cross
section with a standard length of either 5 ft or 6 ft.
These anodes are cast with a 1/2 in. diameter straight electro-galvanized steel core rod for direct
welding or assembly to two flat attachment bars with U bolts to facilitate routine replacement, as
shown in Figure E-5. The U bolts clamp the anode core in place and provide electrical continuity
to the support bar and structure. These U bolts are held in place with nylon insert galvanized
steel lock nuts and washers on the back side of the plate. Either connection should be thoroughly
coated to prevent corrosion attack in any crevices created by the connection. The steel support
plate must be welded to the structure and is typically in. thick x 2 in. wide x 8 in. long. The
core is usually extended 6 in. on both ends and is fastened to the plate so that end of the anode

E-6
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
material is at least 5 6 in. from the mounting plate and also 4 in. away from the structure to
provide good current distribution to the structure being protected.

FIGURE E-5. CONNECTION SCHEMATIC FOR


HIGH-PURITY CAST ZINC BAR ANODES.
The current output of each style anode was calculated using Dwights equation and Ohms law

using a computing Excel spreadsheet specifically designed for this purpose. Tables E-4, E-5,
and E-6 show the computations for the three different zinc rod anodes available.

E-7
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE E-4. HIGH-PURITY ZINC ANODE RESISTANCE CURRENT
OUTPUT AND LIFE CALCULATIONS FOR 1.4 IN. CROSS-SECTION BARE BAR
Variables
Soil Resistivity

Value

Term

1000

Ohm-Cm

Anode Metal

Zn

Anode Alloy

Hi-Purity

Anode Model No.

TZ-27

Anode Weight/Foot

6.75

Pounds

Anode Faradaic Consumption Rate

23.5

Lbs/Amp-Yr.

Anode Efficiency (Percent used to provide CP Current)

90.0%

% Eff.

Utilization Factor

85.0%

UF

Anode Potential (vs. Cu-CuSO4)

1.10

Volts

Desired Cathode Potential (mV vs. Cu-CuSO4)

0.85

Volts

Net Anode-to-Structure Driving Potential

0.25

Volts

Anode Square Dimensions

1.40

Anode Effective Circular Diameter

1.57976

Inches

Bare Anode
Resistance (Ohms)

Total Current
Output (mA)

Zinc Anode Life


(Years)

12

16.1879

15

14.65

24

9.8996

25

17.58

36

7.3039

34

19.39

48

5.8526

43

20.44

60

4.9146

51

21.54

72

4.2538

59

22.35

84

3.7609

66

23.31

Length of 1.4 x 1.4 in. High-Purity Zinc


Bar Anode (in.)

96

3.3777

74

23.76

108

3.0706

81

24.41

120

2.8184

89

24.69

132

2.6074

96

25.18

144

2.4279

103

25.60

156

2.2732

110

25.97

168

2.1384

117

26.29

180

2.0198

124

26.58

192

1.9146

131

26.84

204

1.8205

137

27.27

216

1.7359

144

27.47

228

1.6594

151

27.65

240

1.5898

157

27.99

E-8
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE E-5. HIGH-PURITY ZINC ANODE RESISTANCE CURRENT
OUTPUT AND LIFE CALCULATIONS FOR 2 IN. CROSS-SECTION BARE BAR
Variables
Soil Resistivity

Value

Term

1000

Ohm-Cm

Anode Metal

Zn

Anode Alloy

Hi-Purity

Anode Model No.

TZ50 & TZ60

Anode Weight/Foot

12.5

Pounds

Anode Faradaic Consumption Rate

23.5

Lbs/Amp-Yr.

Anode Efficiency (Percent used to provide CP Current)

90.0%

% Eff.

Utilization Factor

85.0%

UF

Anode Potential (vs. Cu-CuSO4)

1.10

Volts

Desired Cathode Potential (mV vs. Cu-CuSO4)

0.85

Volts

Net Anode-to-Structure Driving Potential

0.25

Volts

Anode Square Dimensions

2.00

Anode Effective Circular Diameter

2.2568

Inches

Bare Anode

Total Current

Zinc Anode Life

Resistance (Ohms)

Output (mA)

(Years)

12

14.3296

17

23.94

24

8.9704

28

29.07

36

6.6845

37

32.99

48

5.3880

46

35.38

60

4.5430

55

36.99

72

3.9441

63

38.75

84

3.4954

72

39.56

96

3.1454

79

41.21

108

2.8641

87

42.09

120

2.6326

95

42.83

132

2.4384

103

43.46

144

2.2730

110

44.39

156

2.1302

117

45.21

168

2.0056

125

45.57

180

1.8959

132

46.24

192

1.7984

139

46.84

204

1.7112

146

47.38

216

1.6327

153

47.87

228

1.5616

160

48.32

240

1.4969

167

48.73

Length of 2 x 2 in. High-Purity Zinc Bar Anode (in.)

E-9
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
TABLE E-6. HIGH-PURITY ZINC ANODE RESISTANCE CURRENT
OUTPUT AND LIFE CALCULATIONS FOR 2.5 IN. CROSS-SECTION BARE BAR
Variables
Soil Resistivity

Value

Term

1000

Ohm-Cm

Anode Metal

Zn

Anode Alloy

Hi-Purity

Anode Model No.

TZ70 & TZ100

Anode Weight/Foot

17.5

Pounds

Anode Faradaic Consumption Rate

23.5

Lbs/Amp-Yr.

Anode Efficiency (Percent used to provide CP Current)

90.0%

% Eff.

Utilization Factor

85.0%

UF

Anode Potential (vs. Cu-CuSO4)

1.10

Volts

Desired Cathode Potential (mV vs. Cu-CuSO4)

0.85

Volts

Net Anode-to-Structure Driving Potential

0.25

Volts

Anode Square Dimensions

2.50

Anode Effective Circular Diameter

2.821

Inches

Bare Anode

Total Current

Zinc Anode

Resistance (Ohms)

Output (mA)

Life (Years)

12

13.1670

19

29.98

24

8.3892

30

37.98

36

6.2969

40

42.73

48

5.0974

49

46.50

60

4.3104

58

49.11

72

3.7503

67

51.02

84

3.3293

75

53.17

96

3.0001

83

54.91

108

2.7349

91

56.34

120

2.5163

99

57.54

132

2.3327

107

58.57

144

2.1761

115

59.44

156

2.0408

123

60.21

168

1.9226

130

61.35

180

1.8184

137

62.37

192

1.7258

145

62.86

204

1.6428

152

63.71

216

1.5681

159

64.49

228

1.5004

167

64.81

240

1.4387

174

65.48

Length of 2.5 x 2.5 in. High-Purity Zinc


Bar Anode (in.)

E-10
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Data from Tables E-4, E-5, and E-6 were used as inputs for Table E-7, which lists the standard
size zinc rod anodes cast by several manufacturers.
TABLE E-7. CURRENT OUTPUT FOR AVAILABLE SIZES OF
HIGH-PURITY ZINC ROD ANODES SUITABLE FOR CIVIL WORKS STRUCTURES
Anode

Lb

W&H

La

Lc

Current Output (mA) in 1000


Ohm-Cm Water

TZ-27

27

1.4"

48"

60"

34

TZ-50

50

2"

48"

60"

46

TZ-60

60

2"

60"

72"

55

TZ-70

70

2 1/2"

48"

60"

49

TZ-100

100

2 1/2"

60"

72"

58

E-2. Design and Input Data for Lock Gate Using High-Potential Magnesium Rod Anodes
The support means for magnesium rod anodes are inherently more fragile than for slabs and
buttons. Generally, they are used only in sheltered areas where waterborne debris will not impact
against the anode. This design example uses the same structure used in Appendices B and D (see
Figure D-1), and the coating and environment conditions are the same as those used in Appendix
D. Therefore, the design input data will not be replicated here because they are identical to those
given in Appendix D, Section D-2. In the current case, however, the use of the rod anodes will
only be applied to the chamber side of the gate.
E-3. Computations and Current Requirements for Each Structure Component
These data are the same as those used in Appendix D, Section D-3. For this example we need
only the first three rows of the existing current requirements table (see Table D-2) because this
design is for the downstream side only. Therefore, the requirements are as shown in Table E-8:
TABLE E-8. CURRENT REQUIREMENTS FOR
EACH DOWNSTREAM STRUCTURE COMPONENT
Side of Gate

Type of
Area

Area
Each
m2

Current
Density I'
2
(mA/m )

1CE

Min. No.
Anodes*

Current
Required
per Unit
(mA)

Current
Required for
All Units (mA)

A&H

Downstream

Chamber

2.78

75.35

.15

31.4

314.2

B&G

Downstream

Chamber

4.34

75.35

.15

49.1

490.5

C, D, E, &
F

Downstream

Chamber

18.9

75.35

.15

213.6

2136.0

Chamber
or Surface
ID

E-11
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
E-4. Anode Design Based on Using Magnesium Rod Anodes
a. Select Anode Alloy
The only available option is high-potential magnesium alloy.
b. Select Anode Size Based on Current Requirement for Each Size Chamber
(1) Chambers A and H
i.

Current Required = 31.4 mA

ii. Initial Anode Selection: Refer to Tables E-1, E-2, and E-3. We note that the water
resistivity of 1900 ohm-cm will reduce the anode current output for a given anode length based
on the following formula:

CurrentOutput =

CurrentOutput (in 1000ohm cm)


1000
environment resistivity (ohm cm )

The rod anodes are designed for vertical suspension. The overall gate height is 18.85 m (35 ft)
divided into 6 uniform height chambers with an internal height of approximately 1.8 m (5.83 ft).
Thus, the maximum anode length in each chamber is approximately 1.5 m (5ft). We calculate
that a 30 cm (12 in.) anode 5 cm (2 in.) in diameter will put out 31.5 milliamperes DC
(60x1000/1900 = 31.5) while the same length anode 6.4 cm (2.5 in.) in diameter will put out 34.2
ma (65x1000/1900 = 34.2). Either size would meet the current required to protect this size
chamber.
iii. Anode Selection Based On Life: We want the anode to last 20 years. Using Tables E2 and E-3 (magnesium anode life column), we see that neither anode will provide the desired
life. The maximum life available can be calculated by the following formula.

CurrentOutput =

AnodeLife(in 1000ohm cm)


environment resistivity (ohm cm)
1000

Per the above, the maximum life would be provided by the 6.4 cm (2.5 in.) diameter by 30 cm
(12 in.) long rod which would have a life of 5.7 years. Based on this, a decision will either have
to be made to use a different style or alloy anode. Alternatively, a plan for replacing the anodes
in the chamber every 6 years could be developed. Since replacing the anodes is fairly easy to do
on the downstream side, this may be a practical solution.

E-12
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
(2) Chambers B and G
i.

Current Required = 49.1 mA

ii. Initial Anode Selection: Refer to Tables E-1, E-2, and E-3. We note that the water
resistivity of 1900 ohm-cm will reduce the anode current output for a given anode length based
on the following formula:

CurrentOutput =

CurrentOutput (in 1000ohm cm)


1000
environment resistivity (ohm cm )

The rod anodes are designed for vertical suspension. The overall gate height is 18.85 m (35 ft)
divided into six uniform-height chambers with an internal height of approximately 1.8 (5.83 ft).
Thus, the maximum anode length in each chamber will be approximately 2.8m (5 ft). We
calculate that a 64 cm (24 in.) anode 5 cm (2 in.) in diameter will put out 51 milliamperes DC
(97x1000/1900 = 51) while the same length anode 6.4 cm (2.5 in.) in diameter will put out 54 ma
(65x1000/1900 = 54). Either size would meet the current required to protect this size chamber.
iii. Anode Selection Based On Life: We want the anode to last 20 years. Using Tables E2 and E-3 we see that neither anode will provide the desired life. The maximum life available
can be calculated by the following formula.

CurrentOutput =

AnodeLife(in 1000ohm cm)


environment resistivity (ohm cm)
1000

Per the above, the maximum life would be provided by the 6.4 cm (2.5 in.) diameter by 61 cm
(24 in.) long rod which would have a life of 7.2 years. Based on this, a decision will have to be
made to either use a different style anode or plan on replacing the anodes in the chamber every 7
years. Since this is fairly easy to do on the downstream side, this may be a practical solution.
(3) Chambers C, D, E, and F
i.

Current Required = 213.6 mA

ii. Initial Anode Selection: Refer to Tables E-1, E-2, and E-3. We note that the water
resistivity of 1900 ohm-cm will reduce the anode current output for a given anode length based
on the following formula:
CurrentOut put =

CurrentOut put (in 1000 ohm cm)


1000
environmen t resistivit y (ohm cm)

E-13
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
The rod anodes are designed for vertical suspension. The overall gate height is 18.85 m (35 ft)
divided into 6 uniform height chambers with an internal height of approximately 1.8 m (5.83 ft).
Thus, the maximum anode length in each chamber will be approximately 150cm (5ft). A quick
check of Tables E-2 and E-3 reveals that a single anode of either diameter will not put out
sufficient current. We calculate that a 150 cm (60 in.) anode 5 cm (2 in.) in diameter will put out
101 milliamperes DC (193x1000/1900 = 101) while the same length anode 6.4 cm (2.5 in.) in
diameter will put out 107 ma (203x1000/1900 = 107). Based on the current requirement of
213.6 ma, we would need either three of the 5 cm diameter anodes per large chamber or two of
the 6.4 cm diameter rods.
iii. Anode Selection Based On Life: We want the anode to last 20 years. Using Tables E2 and E-3 we see that neither anode will provide the desired life. The maximum life available
can be calculated by the following formula.

CurrentOutput =

AnodeLife(in 1000ohm cm)


environment resistivity (ohm cm)
1000

Since we will only need 2 of the larger diameter rods, we will check its life. Per the above, the
maximum life would be provided by the 6.4 cm (2.5 in.) diameter by 152 cm (60 in.) long rod
which would have a life of 9.3 years. Based on this, a decision will have to be made to either use
a different style anode or plan on replace the 6.4 cm diameter anodes in each chamber every 9
years. Since this is fairly easy to do on the downstream side, this may be a practical solution.
c. Develop Anode Locations for Each Structure Element
Locating anodes is simply a geometric process of distributing the anodes uniformly on each
structure element to achieve good current distribution.
Chambers A, B, G, H, I, J, L, and M: In this example, locating of the anodes in the chamber
with one anode only is simple in that the anode will be located in the center horizontally and at a
distance 1/3 of the chamber depth from the back surface of the each chamber. The top of the
anode threaded rod will be fastened so that the anode magnesium body will be approximately 10
cm (4 in.) down from the chamber top plate to enhance current distribution.
Chambers C, D, E, and F: Where more than one anode is required in each chamber, the anodes
again will again all be placed at a distance 1/3 of the chamber depth from the back surface of the
each chamber. In addition, the top of the anode threaded rod will be fastened so that the anode
magnesium body will be approximately 10 cm (4 in.) down from the chamber top plate and at
least 10 cm (4 in.) up from the chamber bottom plate (this latter distance will be a function of the
anode body length but should be no less than 10 cm) to enhance current distribution. The
locations for the anodes in the large chambers is shown in Figure E-6.

E-14
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04

FIGURE E-6. ROD GALVANIC ANODE LOCATIONS


IN LARGEST DOWNSTREAM CHAMBERS
Multiple anodes must be evenly distributed from the side panels of the chamber to achieve more
uniform current distribution. In order to assure good current flow also to the chamber end plates,
the anode spacing is modified so that the center-to-center spacing between the anodes is equal to
the chamber width divided by the number of anodes per chamber. In this design example, with
two anodes per large chamber, the chamber width of 3.7 m is divided by 2 so that the center-tocenter spacing between the two anodes would be 1.85 m and the distance between the anodes and
their adjacent chamber walls is half this distance or 0.93 m.
Note if three anodes were required in this same size chamber, the center-to-center spacing would
be 1.23 m (3.7/3 = 1.23) and the outermost anodes to adjacent chamber walls would be half this
spacing or 0.62 m (1.23/2 = 0.62).
E-5. Design Adaptation for Using High-Purity Zinc Bar Anodes
The support method for the high-purity zinc bar anodes is considerably more sturdy than that
used in magnesium rod anodes. However, like magnesium rods, the zinc bar anodes must be
offset from the gate structure by at least 12.7 cm (5 in.) to achieve effective current distribution.
They also are typically used in sheltered areas where waterborne debris will not impact them.
This zinc bar example shares the same structure, coating, environment, and other assumptions
used in the high-potential magnesium rod anode design, so the first three design step are identical
E-15
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
to those described in sections E-2 and E-3 above. As in the magnesium rod example, this design
example only addresses the downstream side of the gate. It begins at design step 4, in which the
logic for anode selection is presented.
Based on using the same data, we can go to step 3 in the previous example where we created a
current requirement chart for each chamber (in this design, only for the downstream chambers).
We will use the same steps thereafter for the downstream side only.
a. Select Anode Alloy
The cast zinc bar anodes are available only as high-purity zinc alloy with a cross section of either
3.6 cm (1.4 in.), 5.0 cm (2.0 in.) and 6.4 cm (2.5 in.). Their active zinc anode length is either 121
cm (48 in.) or 152 cm (60 in.) with a solid steel core having a diameter of 1.3 cm (0.5 in.). This
core extends 15 cm (6 in.) from each end of the bar.
b. Select Anode Size Based on Current Requirement for Each Size Chamber
(1) Chambers A and H
i.

Current Required = 31.4 mA

ii. Initial Anode Selection: Refer to Tables E-4 through E-7. We note that the water
resistivity of 1900 ohm-cm will reduce the anode current output for a given anode length based
on the following formula:

CurrentOutput =

CurrentOutput (in 1000ohm cm)


1000
environment resistivity (ohm cm)

The zinc bar anodes are designed for either vertical or horizontal suspension. Since these small
chambers are less than 1 meter in width, the anodes will have to be installed vertically. The
overall gate height is 18.85 m (35 ft) divided into six uniform-height chambers with an internal
height of approximately 1.8 m (5.83 ft). Thus, the maximum anode length in each chamber is
approximately 1.5 m (5 ft). We calculate that even the highest-output anode with zinc bar
dimensions of 6.4 cm (2.5 in) square by 152 cm (60 in.) long will only put out about 30.5
milliamperes DC (58x1000/1900 = 30.5). Since this does not quite meet our minimum current
requirement, we will need to use to smaller anodes. We then calculate that the smallest available
zinc bar anode with zinc bar dimensions of 3.6 cm (1.4 in.) square by 91 cm (36 in.) long will put
out about 17.9 milliamperes DC (34x1000/1900 = 17.9). Thus two mounted vertically and
spaced laterally as far apart as possible will generate the desired current.

E-16
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
iii. Anode Selection Based On Life: We want the anode to last 20 years. Using Table E4 we see that this anode will have a life of 19.4 years in 1000 ohm-cm resistivity water. The
maximum life available can be calculated by the following formula.

CurrentOutput =

AnodeLife(in 1000ohm cm)


environment resistivity (ohm cm)
1000

Per the above, the maximum life provided by the 3.6 cm (1.4 in.) square by 91 cm (36 in.) long
zinc bar would be approximately 37 years. Based on this, a decision will have to be made to
either use a different alloy, different style anode, or accept a design with an unusually long life.
Because this service life is not unrealistically long, the anode will be used for the design in this
example
(2) Chambers B and G
i.

Current Required = 49.1 mA

ii. Initial Anode Selection: Refer to Tables E-4 through E-6. We note that the water
resistivity of 1900 ohm-cm will reduce the anode current output for a given anode length based
on the following formula:

CurrentOutput =

CurrentOutput (in 1000ohm cm)


1000
environment resistivity (ohm cm)

The zinc bar anodes are designed for either vertical or horizontal suspension. Again, since these
relatively small chambers are less than 1.2 meter in width, the anodes, the shortest of which is
slightly more than 1.2 meters, will have to be installed vertically. The overall gate height is
18.85m (35 ft) divided into six uniform height chambers with an internal height of approximately
1.8 m (5.83 ft). Thus, the maximum anode length in each chamber is approximately 1.5 m (5 ft).
We calculate that even the highest-output anode with zinc bar dimensions of 6.4 cm (2.5 in.)
square by 152 cm (60 in.) long will only put out about 30.5 milliamperes DC (58x1000/1900 =
30.5). Since this does not nearly meet our minimum current requirement for chambers B and G,
we will need to use two anodes. We then calculate that the smallest available zinc bar anode with
zinc bar dimensions of 3.6 cm (1.4 in.) square by 91 cm (36 in.) long will put out about 17.9
milliamperes DC (34x1000/1900 = 17.9). Thus, even two mounted vertically and spaced
laterally as far apart as possible will not generate the desired current. We then re-calculate based
on the next largest available zinc bar anode with zinc bar dimensions of 5.0 cm (2 in.) square by
122 cm (48 in.) long will put out about 24.2 milliamperes DC (46x1000/1900 = 24.2). Thus,
even two of these next size anodes will not generate the desired current (48.4 ma versus a
minimum requirement of 49.1 ma). By selecting the next size up zinc bar anode with dimensions
of 5.0 cm (2 in.) square by 152 cm (60 in.) long will put out about 28.2 milliamperes DC

E-17
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
(46x1000/1900 = 28.9). Thus, two 5.0 cm (2 in.) square by 152 cm (60 in.) long zinc bar anodes
mounted vertically and spaced laterally as far apart as possible will generate the desired current.
iii. Anode Selection Based On Life: We want the anode to last 20 years. Using Table E5 we see that this anode will have a life of 37 years in 1000 ohm-cm resistivity water. The
maximum life available can be calculated by the following formula.

CurrentOutput =

AnodeLife(in 1000ohm cm)


environment resistivity (ohm cm)
1000

Per the above, the maximum life provided by the 5.0 cm (2.0 in.) square by 152 cm (60 in) long
zinc bar would be approximately 70.3 years. Based on this, a decision will have to be made to
either use a different alloy, different style anode, or accept a design with an unusually long life.
Because this service life is not so unrealistically long, the anode will be used for the design in
this example.
(3) Chambers C, D, E, and F
i.

Current Required = 213.6 mA

ii. Initial Anode Selection: Refer to Tables E-4 through E-6. We note that the water
resistivity of 1900 ohm-cm will reduce the anode current output for a given anode length based
on the following formula:

CurrentOutput =

CurrentOutput (in 1000ohm cm)


1000
environment resistivity (ohm cm)

The zinc bar anodes are designed for either vertical or horizontal suspension. Since these are
much larger chambers with a width of 3.7 meters (12.1 ft) and a height of 1.8 meters (5.83 ft),
the anodes could either be installed horizontally or vertically. The overall gate height is 18.85m
(35 ft) divided into six uniform-height chambers with an internal height of approximately 1.8 m
(5.83 ft). For vertical placement, the maximum anode length in each chamber is approximately
1.5 m (5 ft). For horizontal placement, not only is there no limit in anode length based on those
commercially available, but up to three of the 91 cm (36 in.) anodes could be placed end-to-end
inside each chamber. We then calculate that the smallest available zinc bar anode with
dimensions of 3.6 cm (1.4 in.) square by 91 cm (36 in.) long will put out about 17.9 milliamperes
DC (34x1000/1900 = 17.9). The total number of this size anode required per chamber can be
calculated by dividing the total current per chamber of 213.6 ma by the current per anode of 17.9
which equals 11.9 anodes. Thus, our design will utilize 12 anodes mounted horizontally in four
rows of three each mounted end-to-end with one row mounted on the chamber bottom, two rows
on the chamber back wall, and the final row on the underside of the chamber top.

E-18
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
iii. Anode Selection Based On Life: We want the anode to last 20 years. Using Table E4 we see that this anode will have a life of 19.4 years in 1000 ohm-cm resistivity water. The
maximum life available can be calculated by the following formula.

CurrentOutput =

AnodeLife(in 1000ohm cm)


environment resistivity (ohm cm)
1000

Per the above, the maximum life provided by the 3.6 cm (1.4 in.) square by 91 cm (36 in.) long
zinc bar would be approximately 37 years. Based on this, a decision will have to be made to
either use a different alloy, different style anode, or accept a design with an unusually long life.
Because this life is not so long as to be totally unrealistic, the anode will be used for the design in
this example.
c. Develop Anode Locations for Each Structure Element
Locating anodes is simply a geometric process of distributing the anodes uniformly on each
structure element to achieve good current distribution.
Chambers A and H: Where more than one anode is required in each chamber, the anodes will
be mounted to the back surface of the each chamber held off the surface approximately 15 cm (6
in.) by mounting brackets. Multiple anodes must be evenly distributed from the side panels of
the chamber to achieve more uniform current distribution. In order to also assure good current
flow to the chamber end plates, the anode spacing is modified so that the center-to-center spacing
is equal to the chamber width divided by the number of anodes per chamber. In this design
example, with two anodes per small chamber, the chamber width of 1 m is divided by 2 so that
the center-to-center spacing between the two anodes would be 0.5 m and the distance between
the anodes and their adjacent chamber walls is half this distance, or 0.25 m.
Note that if three anodes were required in this same size chamber, the center-to-center spacing
would be 0.33 m (1/3 = 0.33) and the outermost anodes to adjacent chamber walls would be half
this spacing, or 0.17 m (0.33/2 = 0..17). Note that this spacing from the end walls should never
be less than 0.15 m (6 in.) to ensure that current distribution will relatively uniform.
Chambers B and G: Where more than one anode is required in each chamber, the anodes will
be mounted to the back surface of each chamber held off the surface approximately 15 cm (6 in.)
by mounting brackets. Multiple anodes must be evenly distributed from the side panels of the
chamber to achieve more uniform current distribution. In order to also assure good current flow
to the chamber end plates, the anode spacing is modified so that the center-to-center spacing is
equal to the chamber width divided by the number of anodes per chamber. In this design
example, with two anodes per small chamber, the chamber width of 1.1 m is divided by 2 so that

E-19
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
the center-to-center spacing would be 0.55 m and the distance between the anodes and their
adjacent chamber walls is half that distance, or 0.23 m.
Note if three anodes were required in this same size chamber, the center-to-center spacing would
be 0.37 m (1.1/3 = 0.37) and the outermost anodes to adjacent chamber walls would be half that
spacing, or 0.19 m (0.37/2 = 0.19). Note that this spacing from the end walls should never be
less than 0.15 m (6 in.) to ensure that current distribution will relatively uniform.
Chambers C, D, E, and F: In this design, zinc bar anodes are to be mounted horizontally in
two parallel rows of three anodes each installed end-to-end. Each chamber is approximately 1 m
(3.3 ft) deep by 1.8 m (5.8 ft) by 3.7 m (12.2 ft). Since each anode is 1.2 m (4 ft) long, the
anodes will barely fit end-to-end in a horizontal row. To fit the three anodes into this chamber, a
mounting hole will be drilled into each chamber end plate to receive one end of the nearest
anode. The other threaded end of the anode will be held in place by a mounting plate placed
nd
1.21 m from each end plate. The mounting plate must have a slot into which this 2 end of the
anode support rod can be fitted to be held in place by a nut and bolt. The center anode in each
chamber will also have to mount into these same chamber support plates either by mounting
them into the same support slots or by cutting an additional slot immediately adjacent to the
support slot for the end anode rods. The two rows of anodes would be spaced equally away from
the top and bottom of each chamber.
In this design example, with two horizontal rows of anodes per large chamber, the chamber
height of 1.8 m is divided by 2 so that the center-to-center spacing between the two rows of
anodes would be 0.9 m and the distance between the anodes and their adjacent chamber top and
bottom walls is half that distance, or 0.45 m. If three anodes were required in this same size
chamber, the center-to-center spacing would be 0.6 m (1.8/3 = 0.6) and the outermost anodes to
adjacent chamber walls would be half that spacing, or 0.3 m (0.6/2 = 0.3). Note that this spacing
from the end walls should never be less than 0.15 m (6 in.) to ensure that current distribution will
relatively uniform. The locations for the anodes in the large chambers is shown In Figure E-7.

E-20
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
Gusset
Mounting
Plate
1.2m

1.2m

0.15m min.

1.2m

1m

3.7 m

0.45m

5.7 m

1.2m
0.9m

FIGURE E-7. ZINC BAR GALVANIC ANODE LOCATIONS


IN LARGEST DOWNSTREAM GATE CHAMBERS
As is the case with all galvanic anode designs on civil works structures, the intent is to deploy the
anodes in a way that distributes their protective current uniformly for each similar current density
surface area. For a structure where significantly different densities were required for protection,
however, more anodes would be concentrated in the high-current density areas with fewer
distributed uniformly in the lower current density areas (proportionate to the relative current
densities required).

E-21
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
APPENDIX F
DETAILED GALVANIC CATHODIC PROTECTION DESIGN EXAMPLE BASED ON
LONGVIEW LAKE INTAKE TOWER EMERGENCY DRAWDOWN GATE LEAF
F-1. Design for Drawdown Gate Leafs
Figures F-1 and F-2 show a Longview Lake Emergency Drawdown Gate Leaf. This gate is
approximately 2.13 m (7.0 ft) long and 2.29 m (7 ft - 6 in) high. With the lake at normal water
level, portions of each gate will always be submerged and other portions may be submerged or
exposed as operation changes. During times of high water, more gate surfaces will be
submerged, and under conditions of flood, the entire gates may be submerged. Given these
variable conditions, the cathodic protection system shall be designed to protect both sides of the
gate for its full depth.
12"

7'-0"

1'-9"

1'-9"

1'-9"

1'-9"

1'-6"

1'-6"

7'-6"

1'-6"

1'-6"

1'-6"

13"

13"

13"

13"

13"

13"

Skin Plate Side of Gate Leaf

FIGURE F-1. DRAWDOWN GATE LEAF,


UPSTREAM STRUCTURAL LAYOUT
F-1
More ebooks : http://artikel-software.com/blog

End View
of Gate Leaf

EM 1110-2-2704
12 Jul 04
Chamber Size A

Chamber Size B

4"
10
8"

8"
10
Chamber
Size D

8"
Chamber
Size C

10
8
10
4
4"

Chamber Side of Gate Leaf

4"

FIGURE F-2. DRAWDOWN GATE LEAF,


DOWNSTREAM STRUCTURAL LAYOUT
The leaves are constructed of welded structural steel with both horizontal and vertical framing.
The downstream side of the leaf consists of a pattern of rectangular chambers closed on five
faces and partially open to the water on the sixth face. The upstream face of the leaf is covered
with a single skin plate measuring 213 cm (7 ft) wide by 229 cm (7 ft - 6 in.).
The main (large) chambers (chambers A and B) on the downstream face of the gate are set in four
columns and are approximately 53 cm (1 ft - 9 in.) wide by 46 cm (1 ft - 6 in.) high and a depth
of 30.5 cm (12 in.). The A chambers are partially faced on the top and bottom and on one side by
steel plates that are 10 cm (4 in.) wide, and the B chambers are partially faced only on the top
and bottom by steel plates that are also 10 cm (4 in.) wide. The six smaller bottom chambers
(chambers C and D) are somewhat smaller approximately 33 cm (13 in.) wide by 46 cm (1 ft6 in.) high with a depth of 30.5 cm (12 in.). The two outermost D chambers are partially faced

F-2
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
on the top and bottom and on one side by steel plates that are 10 cm (4 in.) wide, and Chamber C
is partially faced only on the top and bottom by steel plates that are also 10 cm (4 in.) wide.
F-2. Design Data
The following information must be known to design a CP system for this example application or
for any other gate leaf structure and environment:
a. The lock is located in fresh water with a resistivity of 1900 ohm-centimeters. Note that
this information must be measured either onsite or from sample of water obtained onsite. The
sample should be obtained when the water onsite is at its highest resistivity, which is usually in
the fall, when rainfall and run-off are at their lowest for the year).
b. Water velocity is less than 1524 mm/s (5 ft/s).
c. Water contains debris, and icing will occur in the winter.
d. The gate surfaces have a new vinyl paint coating, minimum of 0.15 mm (6 mils) thick,
with not more than 1 percent of the area bare due to holidays in the coating.
e. The coating will deteriorate during 20 years of exposure. Based on recent experience
with the coating systems presently being applied in the field, it is reasonable to assume that 15
percent of the surface area will become bare in 20 years.
f. Design for 75.35 mA/m2 (7.0 mA/ft2) (moving fresh water).
g. Design for a 20-year life.
h. Design for normally submerged surface areas.
i. For galvanic anode systems, anode specifications must be based on the maximum (final)
current requirement over the design life because the current cannot be readjusted over time.
F-3. Computations
a. Find the Surface Area to be Protected
(1) Upstream Side
i.
Area of Skin Plate: The gate leaf has an overall height of 2.29 m and is sometimes
completely submerged. The width of the gate covered by the skin plate measures 2.13 m.
Therefore, the submerged surface area of the skin plate is 2.29 m x 2.13 m = 4.88 m2 (52.5 ft2).

F-3
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
(2) Downstream Side
i.
Largest-Area Downstream A-Chamber Areas: Eight larger chambers adjacent to the
skin plate each have the surface area of a cube on the interior less the open part of the
downstream side plus the exterior 10 cm (4 in.) wide surface plate on three sides. The cube
surface area is the sum of their six side areas, or [2 x (0.53m x 0.46m + 0.53m x 0.30m + 0.46m
x 0.30m) = 2 x 0.541 m2 = 1.08 m2] minus the open area of [0.25 x 0.43 = 0.11 m2] plus the
outside surface area of the 10 cm plate perimeter on three side of [0.10 x (0.53 + 0.53m + 0.25) =
0.131 m2] = 1.08 m2 0.11 m2 + 0.131 m2 = 1.10 m2.
ii. Second-Largest-Area Downstream B-Chamber Areas: Eight larger chambers adjacent
to the skin plate each have the surface area of a cube on the interior minus the open part of the
downstream side plus the exterior 10 cm (4 in.) wide surface plate on three sides. The cube
surface area is the sum of their six side areas [2 x (0.53m x 0.46m + 0.53m x 0.30m + 0.46m x
0.30m) = 2 x 0.541 m2 = 1.08 m2] minus the open area of [0.25 x 0.53 = 0.13 m2] plus the outside
surface area of the 10 cm plate perimeter on two sides of [0.10 x (0.53 + 0.53m) = 0.106 m2] =
1.08 m2 0.13 m2 + 0.106 m2 = 1.06 m2.
iii. Smaller-Area Downstream C-Chamber Areas: Eight of these normally submerged
chambers adjacent to the skin plate each have the surface area of a cube on the interior minus the
open part of the downstream side plus the exterior 10 cm (4 in.) wide surface plate on three sides.
The cube surface area is the sum of their six side areas [2 x (0.33m x 0.46m + 0.33m x 0.30m +
0.46m x 0.30m) = 2 x .39 m2 = 0.78 m2] minus the open area of [0.23 x 0.25 = 0.06 m2] plus the
outside surface area of the 10 cm plate perimeter on three side of [0.10 x (0.33 + 0.33m + 0.25) =
0.091 m2] = 0.78 m2 0.06 m2 + 0.091 m2 = 0.81 m2.
iv. Smallest-Area Downstream D-Chamber Areas: Eight larger normally submerged
chambers adjacent to the skin plate each have the surface area of a cube on the interior minus the
open part of the downstream side plus the exterior 10 cm (4 in.) wide surface plate on three sides.
The cube surface area is the sum of their six side areas [2 x (0.33m x 0.46m + 0.33m x 0.30m +
2
2
2
0.46m x 0.30m) = 2 x .39 m = 0.78 m ] less the open area of [0.23 x 0.25 = 0.06 m ] plus the
outside surface area of the 10 cm plate perimeter on two side of [0.10 x (0.33 + 0.33m) = 0.066
m2] = 0.78 m2 0.06 m2 + 0.066 m2 = 0.79 m2.

F-4
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
(3) Create a Summary Table of Area for Each Chamber
TABLE F-1. CHAMBER AREA VALUES
Area Each

Area Total

Chamber or
Surface ID

Side of
Gate

Type of
Area

Total of
Each

m2

ft2

m2

ft2

Downstream

Chamber

1.1

11.8

8.8

94.7

Downstream

Chamber

1.06

11.4

8.5

91.5

Downstream

Chamber

0.81

8.7

1.62

17.4

Downstream

Chamber

0.79

8.5

3.16

34.0

Skin

Upstream

Chamber

4.88

52.5

4.88

52.5

27.0

290.2

Total Submerged Area

b. Calculate the Current Required for a Single Structure Component


I = A x I'(1.0 - CE)

[EQ 1]

where:
A = surface area to be protected
I' = required current density per bare ft2 of steel submerged to adequately protect gate =
75.35 mA/m2 = 7 mA/ft2
CE = coating efficiency (0.85 at end of 20 years service)
Skin plate requirement:
I = 4.88 m2 x 75.35 mA/m2 x (1 - .085) = 55.2 mA
c. Create a Table of Current Requirements for Each Structure Component
TABLE F-2. CURRENT REQUIREMENTS FOR EACH STRUCTURE COMPONENT
Chamber or
Surface ID

Side of
Gate

No. of
this
Type

Area
Each
m2

Current
Density I'
2
(mA/m )

1 - CE

Min. No.
Anodes*

Current
Required per
Unit (mA)

Current
Required for
All Units (mA)

Downstream

1.1

75.35

0.15

12.4

99.2

Downstream

1.06

75.35

0.15

12.0

96

Downstream

0.81

75.35

0.15

9.2

18.4

Downstream

0.79

75.35

0.15

8.9

35.6

Skin

Upstream

4.88

75.35

0.15

55.2

55.2

Total Current Required:

304.4
2

* To ensure uniform current distribution, it is normally good design practice to provide at least 1 galvanic anode per 10 m structure
surface to be protected.

F-5
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
F-4. Anode Design Based on Using Flush-Mounted Slab or Disk Anodes
a. Select Anode Alloy
Refer to Appendix C, Table C-3, for current output data associated with magnesium and zinc
alloys. Because the water resistivity is approximately 1900 ohm-cm, and considering both the
current output available and required anode life, it is apparent that the preferred alloy anode
material is either H-1 Grade A or B magnesium alloy. Should none of the available shapes
provide sufficient current, then we would re-evaluate using high-potential magnesium alloy
anodes. If anode life would be too short with either magnesium alloy, then consider using highpurity zinc alloy anodes.
b. Select Anode Size
Size is based on current required for each size chamber and the skin plate. Because there are
multiple chamber sizes to consider, start with the smallest surface and then sequentially evaluate
the larger chambers because designing the smaller components is easier and will help familiarize
the designer with the process.
(1) Chamber D
i.

Current Required = 8.9 mA

ii. Initial Anode Selection: Refer to Tables C-4 through C-10 and select the chart with
the resistivity closest to that of the measured water resistivity. In this case, the water resistivity is
1900 ohm-cm, so consult Table C-6. That table includes a bar chart of the data it presents, and
the chart makes it easy to determine which anodes may be appropriate for the D-chambers.
From the chart, we could consider the use of the 1x6x12SBE in high-purity zinc (output = 12
ma), a 2x6x12SCE also in high-purity zinc (output = 9 ma), or a 2x5RCE in H-1 alloy
magnesium (output = 13 ma).
iii. Anode Selection Based On Life: We want the anode to last 20 years. Figure C-2
indicates that only the 2x5RCE magnesium anode will not have enough life (20 years desired) at
13 ma output. Figure C-3 indicates that both zinc anodes have the required life at their respective
outputs of 9 ma and 12 ma. Since the 2x6x12SCE has sufficient life and will provide the desired
current for this chamber, we will install one 2x6x12SCE plastisol-coated high-purity zinc alloy
anode for the two D-chambers. We also check Table F-2 and note that one anode per chamber is
all that is required for good current distribution in these chambers.
(2) Chamber C
i.

Current Required = 9.2 mA

F-6
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
ii. Initial Anode Selection: Refer to Tables C-4 through C-10 and select the chart with
the resistivity closest to that of the measured water resistivity. Since the water resistivity is 1900
ohm-cm, consult Table C-6. That table includes a bar chart of the data it presents, and the chart
makes it easier to discern which anodes may be appropriate for the C-chamber. From the chart,
we could consider the use of the 1x6x12SBE in high-purity zinc (output = 12 ma) or a 2x5RCE
in H-1 alloy magnesium (output = 13 ma). Because the actual water resistivity is 5% less than
the chart value of 2000 ohm-cm, the anodes will put out 5% more current than Table C-6
indicates. Thus we can also consider the use of the 2x6x12SCE in high-purity zinc (output in
1900 ohm-cm = 9.5 ma).
iii. Anode Selection Based On Life: We want the anode to last 20 years. Figure C-2
indicates that only the 2x5RCE magnesium anode will not have enough life (20 years desired) at
13 ma output. Figure C-3 indicates that both zinc anodes have the required life at their respective
outputs of 9.5 ma and 12 ma. Because the 2x6x12SCE has sufficient life and will provide the
desired current for this chamber, we will install one 2x6x12SCE plastisol-coated high-purity zinc
alloy anode for the four C-chambers. Again, we also check Table F-2 and note that one anode
per chamber is all that is required for good current distribution in these chambers.
(3) Chamber B
i.

Current Required = 12 mA

ii. Initial Anode Selection: Refer to Tables C-4 through C-10 and select the chart with
the resistivity closest to that of the measured water resistivity. Since the water resistivity is 1900
ohm-cm, consult Table C-6. That table includes a bar chart of the data it presents, and the chart
makes it easier to discern which anodes may be appropriate for the B-chambers. We will not
consider the 5 in. round magnesium anode since we already know its life will not be sufficient.
Thus, from the chart, we see that the only anode we should consider in magnesium is the
1x6x12SCE in H-1 alloy (output = 23 ma) or the 2x6x12SBE in zinc alloy (output also = 12 ma).
iii. Anode Selection Based On Life: We want the anode to last 20 years. Figure C-2
indicates that the 1x6x12SCE in H-1 alloy magnesium will not have enough life (20 years
desired) at 23 ma output. Figure C-3 indicates that the 2x6x12SBE in zinc alloy (output also =
12 ma) will have the required life. Because the 2x6x12SCE has sufficient life and will provide
the desired current for this chamber, we will install one 2x6x12SBE plastisol-coated high-purity
zinc alloy anode for the eight B-chambers. Also, since we are using zinc with a maximum
driving potential of 1100 mV versus a Cu-CuSO4 reference electrode, we do not have to worry
about cathodic debonding of the coating adjacent to the anode. Therefore, no additional
dielectric shielding is needed behind the anode other than the plastisol coating that will be left in
place on the back side of the anodes and on the core extensions (except around the mounting
bolts where the plastisol must be removed to provide electrical contact between the bolt, core,
anode, and lift gate). Again, we also check Table F-2 and note that one anode per chamber is all
that is required for good current distribution in these chambers.
F-7
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
(4) Chamber A
i.

Current Required = 12.4 mA

ii. Initial Anode Selection: Refer to Tables C-4 through C-10 and select the chart with
the resistivity closest to that of the measured water resistivity. Again, the water resistivity is 1900
ohm-cm, so consult Table C-6. That table includes a bar chart of the data it presents, and the
chart makes it easier to discern which anodes may be appropriate for the A-chambers. We will
not consider the 5 in. round magnesium anode since we already know its life will not be
sufficient. Thus, Table C-6 indicates that the only anode we should consider in magnesium is the
2x6x12SBE in zinc alloy (output = 12.6 ma in 1900 ohm-cm water = 5% greater than the chart
value of 12 ma in 2000 ohm-cm water).
iii. Anode Selection Based On Life: We want the anode to last 20 years. Figure C-2
indicates that the 1x6x12SCE in H-1 alloy magnesium anode will not have enough life (20 years
desired) at 23 ma output. Figure C-3 indicates that the 2x6x12SBE in zinc alloy (output also =
12 ma) will have the required life. Since the 2x6x12SCE has sufficient life and will provide the
desired current for this chamber, we will install one 2x6x12SBE plastisol-coated high-purity zinc
alloy anode for the eight A-chambers. Again, since we are using zinc with a maximum driving
potential of 1100 mV versus a Cu-CuSO4 reference electrode, we do not have to worry about
cathodic debonding of the coating adjacent to the anode. Therefore, no additional dielectric
shielding is needed behind the anode other than the plastisol coating that will be left in place on
the back side of the anodes and on the core extensions (except around the mounting bolts where
the plastisol must be removed to provide electrical contact between the bolt, core, anode and lift
gate). Note we also check Table F-2 to see that one anode per chamber is all that is required for
good current distribution in these chambers.
(5) Skin Plate
i.

Current Required = 55.2 mA

ii. Initial Anode Selection: Refer to Tables C-4 through C-10 and select the chart with
the resistivity closest to that of the measured water resistivity. Since the water resistivity is 1900
ohm-cm, consult Table C-6. That table includes a bar chart of the data it presents, and the chart
makes it easier to discern which anodes may be appropriate for the skin plate. We note that the
only single H-1 alloy anode with sufficient capacity to protect the entire skin plate of the gate
leaf is the 4x9x18SBE anode. However, this bare-edge magnesium anode would require the use
of a supplementary dielectric shield as discussed in the next paragraph. Because such use is not
recommended, we will consider the use of two anodes instead with each having an output of at
least 28ma. The 2x8x8SCE high-potential magnesium alloy anode (30 ma output), the
2x6x12SCE high-potential magnesium alloy anode (32 ma output), and the 2x9x18SCE H-1
alloy magnesium anode (37) could be used. Any one of these three anodes could be used based
on their current output.
F-8
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
iii. Use of Plastisol Coatings: Plastisol restricts the current flow to the anode face, but
after the coating is cut away from the face it improves current distribution (for magnesium
anodes only on coated structure and for both zinc and magnesium on bare structures) because
current from the sides of the anode cannot flow to the steel immediately adjacent to the anode.
With bare-edge magnesium anodes, it is necessary to place a neoprene rubber shield behind the
anode which is extended beyond the anode perimeter at least 2 in. This shield must be glued in
place, typically using 100% silicon caulk. Unfortunately, this shielding material can be damaged
by the ice and debris floating down the river and impacting primarily on the exposed skin plate
anodes. Thus, it is normally recommended that the skin plate anodes be entirely coated with
plastisol, with a window cut from the coating on the anode face to expose the operating surface.
Therefore, we will not consider the use of bare-edge magnesium anodes for any upstream gate or
leaf surface. Bare-edge zinc anodes may be used on coated skin plates since the coating will
function as the dielectric shield without being damaged by the anode current output over the
system design life.
iv. Anode Selection Based On Life: We want the anode to last 20 years. Using Figure
C-2, we see that the 2x8x8 anode will only last about 15 years at 30 ma and therefore is not
suitable for this project. The 2x6x12 also falls slightly short of the desired life at 32 ma output.
Only the 2x9x18SCE H-1 alloy anode will work, providing over 30 years life at 37 ma current
output. Thus, we will install two 2x9x18SCE H-1 magnesium alloy anodes with plastisol-coated
back and sides to protect the skin plate. It should be noted that the use of two anodes exceeds the
minimum number of one anode required for good current distribution, as shown in Table F-2.
c. Develop Anode Locations for Each Structure Element
Locating anodes is simply a geometric process of distributing the anodes uniformly on each
structure element to achieve good current distribution.
(1) Chambers A, B, C, and D
In this example, locating of the anodes in the chamber with one anode only is simple in that the
anode will be located in the center both vertically and horizontally on the back surface of the
each chamber to receive a single anode.
(2) Skin Plate
Since the skin plate will usually require two anodes that will be distributed uniformly both
vertically and horizontally , the design procedure is somewhat simpler than that for the larger
structures designed earlier in this document. Geometrically, the two anodes can either be
distributed vertically along the vertical bisector of the leaf or horizontally along the horizontal
bisector. Since the leaf is taller than it is wide, we choose the former vertical layout. The
topmost anode is simply located one-quarter the way down from the top of the leaf (2.29 m x

F-9
More ebooks : http://artikel-software.com/blog

EM 1110-2-2704
12 Jul 04
0.25 = 0.57 m) and the bottom anode is located one-quarter the way up from the bottom of the
leaf (also 0.57 m).
The layout for these anodes on the skin plate is shown below in Figure F-3.

FIGURE F-3. ANODE CONFIGURATION ON


UPSTREAM SKIN PLATE SIDE OF GATE.

F-10
More ebooks : http://artikel-software.com/blog

Anda mungkin juga menyukai