Comparison Features
ATSProduct Series
185
300
4000
7000
Intended Application
Residential
Light Commercial
Commercial
Light Industrial
Industrial
Mission Critical
Critical Power
100 - 400
30 - 3,000
30 - 4,000
30 - 4,000
Phases Available
Single
Single or Three
Single or Three
Single or Three
2
220 - 240V
2, 3 or 4
115 - 600V
2, 3 or 4
115 - 600V
2, 3 or 4
115 - 600kV
Medium Voltage
N/A
N/A
N/A
5kV, 15kV
Yes
Yes
Yes
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Yes
Yes
Yes
N/A
N/A
N/A
N/A
N/A
N/A
N/A
Yes
Yes
N/A
Yes
Yes
N/A
N/A
N/A
N/A
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
10 -100 kA
10-100 kA
Comparison
Features
Product Type
Open Transition Transfer Switch
Service Entrance Rated Transfer Switch
Power Transfer Load Center
Closed-Transition Transfer Switch
Delayed-Transition Transfer Swtich
Soft Load Transfer
Bypass-Isolation Transfer Switch
Closed-Transition Bypass-Isolation TS
Delayed-Transition Bypass-Isolation TS
Soft Load Bypass-Isolation TS
N/A
10kA -42kA
100 -200kA
N/A
22 -100kA
100 -200kA
N/A
22 -100kA
100 -200kA
36-65kA
22 -100kA
100 -200kA
36-65kA
STD
STD
Yes
Yes
N/A
N/A
Yes
N/A
Yes
N/A
Yes
Yes
N/A
Neutral Configuration
Solid
Switched
Overlap
ATSProduct Series
Comparison
185
300
4000
7000
Single Phase
198 Volts
154-187 Volts
198 Volts
165 Volts
50 or 60Hz
48 or 57Hz
90% or 95%
70% to 90%
90% Fixed
75% Fixed
50 or 60 Hz
95% Fixed
85 to 100%
70 to 98%
85 to 100%
70 to 98%
50 or 60 Hz
90 to 100%
85 to 100%
70 to 98%
85 to 100%
70 to 98%
50 or 60 Hz
90 to 100%
43 or 51Hz
N/A
N/A
N/A
N/A
85% Fixed
N/A
N/A
N/A
N/A
85 to 98%
102 to 115%
102 to 115%
102 to 110%
102 to 110%
85 to 98%
102 to 115%
102 to 115%
102 to 110%
102 to 110%
N/A
N/A
N/A
90 to 100%
85 to 98%
Yes
90 to 100%
85 to 98%
Yes
1 or 3 Seconds
0 or 5 Minutes
1 Sec. to 30 Mins.
5 Minutes
4 Seconds
7 Day
0 to 6 Seconds
0 to 60 Minutes
0 to 60 Minutes
0 to 60 Minutes
0 to 60 Minutes
Programmable
0 to 6 Seconds
0 to 60 Minutes
0 to 60 Minutes
0 to 60 Minutes
0 to 60 Minutes
Programmable
N/A
N/A
N/A
1 or 3 Seconds
10 Seconds
15 Minutes
5 Minutes
4 Seconds
7 Day
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
STD
STD
STD
STD
Yes
N/A
N/A
N/A
Yes
Yes
Yes
STD
Yes
Yes
Yes
Optional
Yes
Yes
Yes
Optional
Power Manager
N/A
N/A
N/A
N/A
Yes
Optional
Yes
Optional
N/A
N/A
Yes
Optional
Yes
Yes
N/A
N/A
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
N/A
Yes
Yes
Yes
N/A
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Enclosures
Type 1
Type 3R
Type 4
Type 4X
Type 12
Connectivity
RS-485 Serial
Ethernet
Modbus
Monitoring and Control via ASCOProducts
Optional Accessories
Optional
Limited
Limited
Extensive