Anda di halaman 1dari 16

Pexgol Installation Guidelines

for Infrastructure pipelines

Pexgol Installation Guidelines for Infrastructure pipelines

Single House Inlet

Pexgol 32 - 63

Transition Elbows
Plasson 492504
Plasson 493504
Plasson 494504
Plasson 4945M4
Frialen WUN 90

EF 90 Elbow
Plasson 490504
Frialen W90

2
ol 3

-6

Pex

Pe

xg

ol

90

EF Coupler
Plasson 490104
Frialen WN
-2

25

EF Branch Saddle
PLasson 495804
63/75/90/110/160 with outlet sizes 32/ 40/50/63
200/225 with outlet sizes 63 and 90
For Diameters above 225mm use Tee Connector

Pexgol Installation Guidelines for Infrastructure pipelines

Duplex (double - house) inlet


EF Couplers 32 to 63mm

Transition Elbows
Plasson 492504
Plasson 493504
Plasson 494504
Plasson 4945M4
Frialen WUN 90

PVC 110
Conduit Pipe
with Concrete
inside

Pexgol

Pexgol

Meter

x
Pe

go

EF 90 Elbow
Plasson 490504
Frialen W90

x
Pe

go

EF Coupler
Plasson 490104
Frialen WN
Pe

xg

ol

Spigot Reducer
PLasson 491107
EF Reducing Tee
PLasson 491404

Pe

xg

ol

90

-2

25

EF Branch Saddle
PLasson 495804
63/75/90/110/160 with outlet sizes 32/ 40/50/63
200/225 with outlet sizes 63 and 90
For Diameters above 225mm use Tee Connector

Pexgol Installation Guidelines for Infrastructure pipelines

Two-House Inlet
Duplex (double - house) inlet

Meter

Pexgol

Mechanical Transition Elbow


PLasson 071506

Pexgol

EF 90 Elbow
PLasson 490504
Frialen - W90

PVC 110
Conduit Pipe
with Concrete
inside

x
Pe

go

Pe

EF Coupler
Plasson 490104
Frialen WN

xg

ol

Spigot Reducer
PLasson 491107
Pe

Pe

xg

ol

90

xg

ol

EF Reducing Tee
PLasson 491404

-2

25

EF Branch Saddle
PLasson 495804
63/75/90/110/160 with outlet sizes 32/ 40/50/63
200/225 with outlet sizes 63 and 90
For Diameters above 225mm use Tee Connectors

Pexgol Installation Guidelines for Infrastructure pipelines

Duplex (double - house) inlet

Meter

Pexgol 50

Plasson
2 Outlet Manifold Kit
Cat No. 078126050007
The Valves and Meters
are not Applied by Plasson

l5

go
Pex

Pe

xg

ol

90

EF Coupler
Plasson 490104
Frialen WN
-2

25

EF Branch Saddle
PLasson 495804
63/75/90/110/160 with outlet sizes 32/ 40/50/63
200/225 with outlet sizes 63 and 90
For Diameters above 225mm use Tee Connector

EF 90 Elbow
Plasson 490504
Frialen W90

Pexgol Installation Guidelines for Infrastructure pipelines

90mm (3) Inlet to Apartment Blocks


Flange Adaptors 3/80
Plasson 49020 Flange Adaptor
Plasson 09903 Flange Backing Ring
According to DIN 2501
Frialen - EFL According to DIN 2501
Also Available:
Pexgol Stub End & Steel Flange - According to any required
flange standard!
EF 90 Elbow 90mm
Plasson 490504
Frialen W90

Pexgol 90mm

l9

o
xg

Pe

EF Coupler
Plasson 490104
Frialen WN
Pe

xg
ol
EF Branch Saddle
11
0
PLasson 495804
-2
25
63/75/90/110/160 with outlet sizes 32/ 40/50/63
200/225 with outlet sizes 63 and 90
For Diameters above 225mm use Tee Connector

Pexgol Installation Guidelines for Infrastructure pipelines

Reducing Tee up to 250mm

ol

0
25

xg

Pe

EF Reducing Tee
PLasson 491404

Pe

xg

ol

mm

25

0m

11-1

EF Coupler
Plasson 490104
Frialen WN

Equal Tee up to 250mm


m

0m

xg

Pe

EF Tee 90 up to 250mm
PLasson 491404
Frialen - TA (kit) up to 63mm
For bigger sizes see Frialen Tee pieces

Pe

xg

ol

25

0m

5
l2

m
EF Coupler
Plasson 490104
Frialen WN

Pexgol Installation Guidelines for Infrastructure pipelines

Frialen Equal Tee Pieces

Pe

xg
ol
2

50

From 75mm up to 225mm

Pe
Frialen - TA (kit) up to 63mm
For bigger sizes see Frialen Tee pieces

xg

ol

25

0m

Pexgol Installation Guidelines for Infrastructure pipelines

Reducing Tee above 280mm


Reducing Spigot Tee
Plasson 461407/491407

EF Coupler
Plasson 490104
Frialen WN

Pe

xg

EF Coupler
Plasson 490104
Frialen WN

ol

28

0m

Reducing Spigot Tee


Plasson 461407/491407

Equal Tee above 280mm


Spigot Tee
Plasson 460407/490407

EF Coupler
Plasson 490104
Frialen WN
EF Coupler
Plasson 490104
Frialen WN

Pe

xg

ol

28

0m

Pexgol Installation Guidelines for Infrastructure pipelines

Outlet with a single shut-off valve


3, 4, 6
Washers Should be
Used with
Plastic - Coated Flanges.

Plastic Ballvalve
Plasson 436207 up to 125mm
Frialen KH
Frialen KHP up to 225mm
Cast Iron Gate Valve with PEX/PE (weldable) ends:
AVK 36-075-80163
Diameters 75 to 315mm

11-1

EF Coupler
Plasson 490104
Frialen WN

PE
XG
OL

Flange Adaptor & Backing Ring


Plasson 490207
Plasson 09903

EF Reducing Tee
Plasson 491404

11-1

Pexgol Installation Guidelines for Infrastructure pipelines

Shut off valve - Above ground installation


(Up to 160mm) with steel pipes
Always use the
suitable flange
standard!

Steel Pipe

Flange Adaptor & Backing Ring


Plasson 490207
Plasson 09903
EF Coupler
Plasson 490104
Frialen WN

Pexgol Installation Guidelines for Infrastructure pipelines

Shut off Valve - Above Ground Installation


Air Relief Valve 2

2 Male Transition Coupler


Plasson 492104
Frialen MUN

Valve 2

Shut-Off Valve 3/4/6

Flange Adaptor & Backing Ring


Plasson 490207
Plasson 09903

Pexgol

EF 90 Elbow
PLasson 490504
Frialen - W90

EF Branch Saddle
Plasson 495804
outlet 63

Pexgol

Washers
Should be
Used with
Plastic Coated
Flanges.

Pex

go

EF 90 Elbow
PLasson 490504
Frialen - W90

Pexgol Installation Guidelines for Infrastructure pipelines

Underground Shut - off Valve


in a Amnhole
Always use the
suitable flange
standard!

EF Coupler
Plasson 490104
Frialen WN
Flange Adaptor & Backing Ring
Plasson 490207
Plasson 09903

EF Coupler
Plasson 490104
Frialen WN

Pexgol Installation Guidelines for Infrastructure pipelines

Air Relief Valve 3/2

Air Relief Valve 3/2

Angle Seat Valve 3/2

Ball Valve 3/4

Metal Riser 3/2


Transition Fitting
Frialen USTM/USTN
63 x 2

EF Coupler
Plasson 490104
Frialen WN

EF Branch Saddle 495804


110 /160 x 90/63

Pe

xg

ol

11

0-

16

Pexgol Installation Guidelines for Infrastructure pipelines

Fire Hydrant 3
Fire Hydrant 3

Metal Riser 4x3

No - Flood
Safety Device 4x3

Golan GP Hydrant Flange Adaptor

Pexgol 110

Golan Hydrant Pexgol

l
go

Pex

EF Reducing Tee
PLasson 491404 160x110x160
PLasson 490404 110x110x110

11

EF 90 Elbow
Plasson 490504
Frialen W90

Pe

EF Coupler
Plasson 490104
Frialen WN
xg

ol

11

0-

16

Pexgol Installation Guidelines for Infrastructure pipelines

Fire Hydrant 3
Fire Hydrant 3

PE/Cast Iron - Flange Transition Coupler


Plasson 497704 110x4
Metal Riser 4x3

No - Flood
Safety Device 4x3

PEXGOL 110

EF 90 Elbow
Plasson 490504
Frialen W90

Pe

EF Reducing Tee
PLasson 491404 160x110x160
PLasson 490404 110x110x110

xg

ol

11

0-

EF Coupler
Plasson 490104
Frialen WN
16