EXPENSION LOOP

Length ( meter ) =
Expension

dia of pipe (mm) X Expension (mm)

Total Length Length/2


1475
738

7.38

X 0.1

Exp.(inch) Exp. (mm)


5.16
131.13

Dia of pipe
(inch)

Dia of pipe
(mm)

Expension
(mm)

Sq.Root

X 0.1

Expension loop
Meters

Expension loop
( Feet)

24

609.60

131.13

282.73

28.27

28.27

92.73

TO CALCULATE DIA. OF PIPE

D2 = 0.75 X Q / VELOCITY X PF
D = DIA, OF PIPE
Q = QTY. OF GAS ST.CU.FT./HRS.
PF = PRESSURE FACTOR = PRESSURE X 14.7
VILOCITY = 30 FT./ SEC.
MMCFD

D2 =
D=

0.75
125000

MCFH

0.75 X MCFH

PRESSURE

120

5000000

3750000

125

894.77452

29.91

MCFH

0.75 X MCFH

PRESSURE

200

8333333.3

6250000

170

676.77315

26.01

D2 = 0.75 X Q / VELOCITY X PF
D = DIA, OF PIPE
Q = QTY. OF GAS ST.CU.FT./HRS.
PF = PRESSURE FACTOR = PRESSURE X 14.7
VILOCITY = 50 FT./ SEC.
MMCFD
2

D =
D=

0.75
125000

STP

PF

14.7

139.7

PF
14.7

184.7