Anda di halaman 1dari 4

80% Enhanced Gas Furnace

Upflow/Horizontal
HEAT EXCHANGER

Efficient aluminized steel tapered S-curve design


Crimped no weld construction for longer life

CABINET

Compact 40" height


Insulated to increase efficiency and reduce sound
levels
Unitized construction for cabinet integrity
Prepainted baked polyester steel for
maximum durability

BLOWER

G2D80BT

Isolated and insulated compartment to reduce sound


levels
Easily removable slide-out design
Multi-speed for wide airflow range
PSC permanently lubricated motors for
low maintenance and optimum efficiency
Dynamically balanced blower with resilient motor
mounts for smooth and quiet operation

BURNERS

Aluminized steel inshot burners for quiet ignition


Sealed combustion burner enclosure for quiet
operation

CONTROLS

Honeywell two stage gas valve


Integrated two stage ignition and fan control board
Board features self diagnostics saving last five (5)
fault codes in nonvolatile memory for ease of service
Provides reverse polarity identification
Hot surface ignition using steel shrouded, high density
mini-ignitor
Control board features adjustable fan off time in the
heating mode and a 60 second fan off time delay in
the cooling mode
Control board provides terminals for electronic air
cleaner, humidifier, furnace twinning, and continuous
low speed fan operations
Control circuit is fuse protected
40 VA transformer
Color coded control wiring
Single or two stage thermostat ready with selectable
timings

VENTING

Draft motor with stainless steel shaft and


fan cooling for long life
Direct vent capable - one or two pipe
Outside combustion air optional

INSTALLATION

Left or right two pipe gas entry


Left or right electrical power entry
Knock out base for bottom return
L models comply with California Energy Commission
Low NOx regulations

ACCESSORIES

Propane conversion kit


Twinning kits
"Flush fit" coils

WARRANTY

Limited lifetime heat exchanger warranty for


direct vent applications
20 year limited heat exchanger warranty for
all other applications
5 year limited on all parts
Extended protection plans available

Model Number Guide


G

2D

80

100

20

G - Product Family

1A
1A
Series

2D - Two Stage Heat,


Direct Vent

L - Low NOx Model


Cabinet Width
B = 17 1/2"
C = 21"
D = 24 1/2"

Nominal AFUE
B - Series
T - Upflow/Horizontal

Nom. Maximum CFM x 100


D - Direct Drive

Nom. Btuh Input x 1000

Physical and Electrical Data


Model
G2D80BT050D12B
G2D80BT075D14B
G2D80BT100D14B
G2D80BT100D20C
G2D80BT125D20C
G2D80BT150D20D

Input
(Btuh)

Output
(Btuh)

50,000 40,000
75,000 60,000
100,000 80,000
100,000 80,000
125,000 100,000
150,000 120,000

AFUE

Nom.
Cooling
Cap.

Gas
Inlet
(in.)

Flue
Size
(in.)

80
80
80
80
80
80

1.5-3.0
2.0-3.5
2.0-3.5
3.0-5.0
3.0-5.0
3.0-5.0

1/2
1/2
1/2
1/2
1/2
1/2

4
4
5
5
5
5

Min. Time
Volts/
Delay
Nominal
Hz/Phase Breaker
F.L.A.
or Fuse
120/60/1
15
5.9
120/60/1
15
7.7
120/60/1
15
7.3
120/60/1
15
11.7
120/60/1
15
11.0
120/60/1
15
11.5

Trans.
(V.A.)

Weight
(lbs.)

40
40
40
40
40
40

125
140
155
180
190
200

Filter Requirement Data


Airflow
Descriptor
12
14
16
20

Disposable Filters
Min. Area
(sq. in.)
576
672
768
960

Size
(in.)
16 x 20
20 x 20
20 x 20
20 x 25

Permanent Filters
Quantity
2
2
2
2

Min. Area
(sq. in.)
288
336
384
480

Size
(in.)
16 x 20
20 x 20
20 x 20
20 x 25

Quantity

1. The Airflow Descriptor is the two digits following the "D" in the model number; e.g. "20" is the Airflow Descriptor for G2080BT100D20C.
2. Areas and dimensions shown for permanent filters are based on filters rated at 600 feet per minute face velocity.
3. Typical filter sizes are shown, however, any combination of filters whose area equals or exceeds the minimum area shown is satisfactory.

1
1
1
1

Blower Performance Data


Model

G2D80BT050D12B

G2D80BT075D14B

G2D80BT100D14B

G2D80BT100D20C

G2D80BT125D20C

G2D80BT150D20D

Motor
Temp.
Blower
Blower
Size
Rise
Size
Speed
(hp)
(oF)
Hi
Med/Hi
1/3
10 x 6 30-60
Med
Low
Hi
Med/Hi
1/3
10 x 8 40-70
Med
Low
Hi
Med/Hi
1/3
10 x 8 50-80
Med
Low
Hi
Med/Hi
3/4
12 x 10 45-75
Med
Med/Low
Low
Hi
Med/Hi
Med
3/ 4
12 x 10 45-75
Med/Low
Low
Hi
Med/Hi
3/4
12 x 10 55-85
Med
Med/Low
Low

*CFM @ ext. Static Pressure - in. w.c. with Filter(s)


.20

.30

.40

.50

.60

.70

.80

.90

1,346
1,119
918
787
1,653
1,355
1,078
917
1,658
1,394
1,104
931
2,161
1,791
1,558
1,284
1,004
2,097
1,780
1,569
1,310
1,017
2,035
1,694
1,480
1,255
987

1,315
1,096
905
764
1,600
1,335
1,061
910
1,609
1,360
1,101
925
2,134
1,767
1,525
1,260
970
2,082
1,757
1,529
1,283
973
2,018
1,684
1,470
1,229
952

1,269
1,067
883
745
1,542
1,306
1,051
886
1,538
1,325
1,077
904
2,098
1,744
1,514
1,243
927
2,037
1,733
1,521
1,253
950
1,974
1,663
1,449
1,205
920

1,216
1,035
843
713
1,476
1,268
1,032
869
1,474
1,282
1,047
880
2,042
1,722
1,495
1,208
892
1,971
1,707
1,486
1,225
907
1,949
1,635
1,420
1,178
889

1,153
981
806
667
1,395
1,206
999
833
1,413
1,227
1,009
843
2,003
1,684
1,455
1,183
850
1,923
1,646
1,434
1,189
828
1,897
1,590
1,384
1,149
830

1,080
922
767
639
1,309
1,156
963
795
1,337
1,163
969
793
1,943
1,647
1,412
1,150
809
1,821
1,563
1,395
1,156
774
1,856
1,540
1,338
1,096
784

995
852
719
579
1,232
1,060
899
671
1,243
1,036
903
645
1,859
1,592
1,376
1,102
741
1,737
1,529
1,351
1,094
720
1,782
1,482
1,268
1,063
734

909
796
644
523
1,107
992
680
582
1,107
959
830
571
1,787
1,523
1,321
1,068
686
1,750
1,467
1,237
1,020
655
1,683
1,417
1,208
1,003
679

*.50 in. w.c. Max. Approved Ext. Static Pressure

Accessories
Kit Number
ALPKT582-1
AFILT524-1
AMB20A-1
AFILT529-1
AFUSE576

Description
Propane Conversion Kit
Horizontal/Upflow Side Return Filter Kit
(16 x 25 filter)
Filter Kit
Bottom Return Kit
Fuse Kit

Used with
All Ultra V Enhanced 80 Furnaces
Ultra V 80 Upflow/Horizontal Series
All Ultra V Upflow Series
Ultra V 80 Upflow and Horizontal Series
All Ultra V Models

Dimensions (in.)
Model

G2D80BT050D12B 17 1/2 16 1/2 14

6 1/2

G2D80BT075D14B 17 1/2 16 1/2 14

6 1/2 4 3/8 3 1/8

G2D80BT100D14B 17 1/2 16 1/2 14

6 1/2 4 1/2 3 1/4

G2D80BT100D20C

21

20 16 1/2 8 1/4 6 1/4 3 5/16

G2D80BT125D20C

21

20 16 1/2 8 1/4 4 5/8 3 1/4

G2D80BT150D20D 24 1/2 23 1/2

21

10

4
D
Supply

E
F
A
B

4 7/8 3 5/16

1/2

3/4
3-1/2

5-7/8 R. side
2-5/8 L. side
Gas Inlet
(R & L side)

Upflow
40

27-1/2

G2D80BT050D12B
G2D80BT075D14B

3-5/8
Control Wiring
(R & L side)

32-11/16

Right Left
Top
Front Back Vent
Side Side

Model

16-1/2
14

G2D80BT100D14B
G2D80BT100D20C
G2D80BT125D20C
G2D80BT150D20D
0" if B1 vent is used

1" if B1 vent is used

2" if B1 vent is used

1/2

Power Wiring
(R & L side)

Clearances* (in.)

28-1/2
19-9/16

43

62

43

62

Side Return
(R & L side)

2 1/16
4-15/16

22

1-3/4

Bottom Return
(Knockout)

2-5/8

22

Horizontal
Model
G2D80BT050D12B
G2D80BT075D14B
G2D80BT100D14B
G2D80BT100D20C
G2D80BT125D20C
G2D80BT150D20D

Right Left
Front Back Vent
Side Side

Airflow
R to L
L to R
Top Bottom Top Bottom

18

32

32

18

21

21

18

0" if B1 vent is used


2
1" if B1 vent is used
3
2" if B1 vent is used

*Clearances to combustibles. Service access to the front of the appliance to


remove the blower assembly is 18".

Specifications subject to change


without notice.

Form # AG2D80BT-100 (9/04)


Printed in U.S.A.

421 Monroe Street Bellevue, OH 44811


(419) 483-4840
www.armstrongair.com
Armstrong Air Conditioning Inc. 2004

*JG2D80BT-100-8-04*