Anda di halaman 1dari 12

Data Sheet 10/63-6.60-EN Rev.

FOUNDATION fieldbus
Junctions, Connectors, Accessories

Operate
Engineer

Ethernet

OPC
Server

Control

FOUNDATION Fieldbus-HSE

FOUNDATION Fieldbus-H1

FOUNDATION Fieldbus-H1

Linking
Device

Field

FOUNDATION fieldbus-H1
Junctions
Connectors
Accessories

Data Sheet

Contents

FOUNDATION fieldbus
Junctions, Connectors, Accessories

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

The FOUNDATION fieldbus-H1 T-Connectors are available as Standard and Ex(Haz.) version. They are used for coupling
1 up to 4 transmitters to the H1 trunk via spurs. The spurs can be connected direct via the EMC cable gland.
Non-interrupted BUS operation when exchanging or extending a H1 transmitter
Easy to use
Low installation costs
External grounding cable
Pressure-compensation element
EMC cable gland
Tension spring connection
Aluminium (standard) housing
Non-Ex design (integrated bus termination, switchable)
Ex(Haz.) design acc. to ATEX (external bus termination with NPZ100-EX)

NPJ130-NO, NPJ460-NO FOUNDATION fieldbus-H1 Junctions Non-Ex version


Recommendation of mounting

Shield is connected to the enclosure via the EMC cable glands.


Thread the cable gland onto the seal, on the unprepared
fieldbus cable
Strip fieldbus cable here
Fieldbus cable
Shielding

Use ferrules!

8
Draw back the shielding braid
over the sheath of the fieldbus cable

50 70

Technical data
Temperature range
Operating temperature
Type of protection
Material of housing
Surface
FOUNDATION fieldbus-H1 connection
Cable bushing
Clamping area

-40 ... 85 C
IP 66
High-quality aluminium alloy (AL-Si 12)
Stove-enamelled NPJxxx: RAL 7001
Tension spring 0.5 ... 1.5 mm2
EMC cable gland M16
5.5 ... 9.6 mm

Installation advice
Torques
M16 cable gland on housing
Coupling ring M16 cable gland
Housing lid
External earthing cable

6.25 Nm
4.5 Nm
1.8 ... 2.0 Nm
1.8 ... 2.0 Nm

M00694

M00728

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

NPJ130-NO FOUNDATION fieldbus-H1 Junction Non-Ex version, with bus termination


The Transmitter (spur, 1-way) are connected using cable bushing

36,5

A
S
19

A
S
B

B
Bus Terminator

58

100R
A

R1
off

off on

R1

Wire bridge

C1

C1
1uF 50Vdc

on

A
S
B
n.c.

Bus terminator
A S B
Enclosure

off

on

(-)
(1)
Shielding (3)
(+)
(2)
(4)

64

M00729

NPJ460-NO FOUNDATION fieldbus-H1 Junction Non-Ex version, with bus termination


The Transmitter (spurs, 4-way) are connected using cable bushing
A
S
B

36,5

B
Bus Terminator

off on

80

19

A
S

Wire
bridge
off

100R

1uF
63V

on
R1

C1

Bus terminator

off
125

on

Enclosure

A S B

A S B

A S B

S B

A
S
B
n.c.

(-)
(1)
Shielding (3)
(+)
(2)
(4)
M00730

All drawings not scaled! All units in millimeter!

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

NPJ130-EX, NPJ460-EX FOUNDATION fieldbus-H1 Junctions Ex area Ex (ia) ATEX

Recommendation of mounting

Shield is connected to the enclosure via the EMC cable glands.


Thread the cable gland onto the seal, on the unprepared
fieldbus cable
Strip fieldbus cable here
Fieldbus cable
Shielding

Use ferrules!

8
Draw back the shielding braid
over the sheath of the fieldbus cable

50 70

Technical data
Temperature range
Operating temperature
Type of protection
Material of housing
Surface
FOUNDATION fieldbus-H1 connection
Cable bushing
Clamping area
ATEX Certification

-40 ... 80 C
IP 66
High-quality aluminium alloy (AL-Si 12)
Stove-enamelled NPJxxx: RAL 5015
Tension spring 0.5 ... 1.5 mm2
EMC cable gland M16
5.5 ... 9.6 mm
II 2 G Ex ia IIC T6

Installation advice
Torques
M16 cable gland on housing
Coupling ring M16 cable gland
Housing lid
Adapter / spur cable
External earthing cable

6.25 Nm
4.5 Nm
1.8 ... 2.0 Nm
Hand-tight
1.8 ... 2.0 Nm

M00694

M00731

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

NPJ130-EX FOUNDATION fieldbus-H1 Junction Ex area Ex (ia) ATEX, without bus termination

36,5

The Transmitter (spur, 1-way) are connected using cable bushing

58

19
A

A
S

Wire bridge

Bus terminator:
With external
NPZ100-EX only

A S B

A
S
B
n.c.

(-)
(1)
Shielding (3)
(+)
(2)
(4)

Enclosure
M00732

64

NPJ460-EX FOUNDATION fieldbus-H1 Junction Ex area Ex (ia) ATEX, without bus termination
The Transmitter (spurs, 4-way) are connected using cable bushing

36,5

80

19

A
S
B

A
S
B

A
S
B
n.c.

Wire
bridge

Bus terminator:
With external
NPZ100-EX only
125

Enclosure

A S B

A S B

A S B

(-)
(1)
Shielding (3)
(+)
(2)
(4)

A S B
M00733

All drawings not scaled! All units in millimeter!

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

NPZ100-EX FOUNDATION fieldbus-H1 Bus Terminator Ex area Ex (ia) ATEX

Cable brown

06

II 2 G D T 80C IP 67

EEx ia IIC T6 EEx m II T6


Ui
17,5 V 10 30 V
Ii
380 mA
Ta: -40 80 C

KEMA 01 ATEX 1058 X


17

0344

Cable white

M00705

Technical data
Temperature range
Operating temperature
Type of protection
Material of housing
Surface
Connecting cable
Cable bushing
ATEX Certification

-40 ... 80 C
IP 66
High-quality aluminium alloy (AL-Si 12)
Black powder coated
2 x 0.14 mm2
Bus adapter M16
II 2 G Ex ia IIC T6, II 2 G Ex m II T6

Installation advice
Torques
M16 adapter on the housing
External earthing cable (if necessary)

6.0 Nm
1.8 ... 2.0 Nm

30,5

45

20
II 2 G D T 80C IP 67

EEx ia IIC T6 EEx m II T6


Ui
17,5 V 10 30 V
Ii
380 mA

49

06

Ta: -40 80 C

KEMA 01 ATEX 1058 X


17

0344

M00706

30,5

All drawings not scaled! All units in millimeter!

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

NFE100-NE FOUNDATION fieldbus-H1 plug 7/8, for Ex and Non-Ex area

M00736

Technical data
Poles
Interlock
Type of connection
Cross-sectional area of connection
Cross-sectional area of connection
Cable diameter
Housing protection
Mechanical life
Upper temperature limit
Lower temperature limit

4 poles
Screw 7/8 UNF
Screw
Max. 1.5 mm2
16 AWG
6 ... 8 mm
IP 67
> 500 plug cycles
85 C
-40 C

Electrical data
Rated voltage
Rated surge voltage
Contamination class
Overvoltage category
Isolation group
Test voltage
Rated current
Volume resistivity
Insulation resistance

250 V
4000 V
3
II
III
4800 V
9 A (40 C)
5 M
1010

Materials
Contact pin
Contact surface
Socket
Plug
Thread ring

CuZn
(brass)
Au
(gold)
PUR/PA (UL 94 HB)
PBT
(UL 94 V-0)
Aluminum eloxaded

Installation advice
Screw terminals
Coupling ring PG cable gland
Knurled screw

Torques
0.4 Nm
4.0 Nm
Hand-tight

~ 83
1,5

~ 3.3

Male
1
2
3
4

wire-colour bus
blue
(-)
orange
(+)
shield
not used
n.c.

referenz
A
B
S

All drawings not scaled! All units in millimeter!

M00738

.96

24,5

1.06

7/8 - 16 UN

27

.06

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

NFE300-NE FOUNDATION fieldbus-H1 socket 7/8, for Ex and Non-Ex area

M00737

Technical data
Poles
Interlock
Type of connection
Cross-sectional area of connection
Cross-sectional area of connection
Cable diameter
Housing protection
Mechanical life
Upper temperature limit
Lower temperature limit

4 poles
Screw 7/8 UNF
Screw
Max. 1.5 mm2
16 AWG
6 ... 8 mm
IP 67
> 500 plug cycles
85 C
-40 C

Electrical data
Rated voltage
Rated surge voltage
Contamination class
Overvoltage category
Isolation group
Test voltage
Rated current
Volume resistivity
Insulation resistance

250 V
4000 V
3
II
III
4800 V
9 A (40 C)
5 M
1010

Materials
Contact pin
Contact surface
Socket
Plug
Thread ring

CuZn
(brass)
Au
(gold)
PUR/PA (UL 94 HB)
PBT
(UL 94 V-0)
Aluminum eloxaded

Installation advice
Screw terminals
Coupling ring PG cable gland
Knurled screw

Torques
0.4 Nm
4.0 Nm
Hand-tight

~ 78,5

Male
1
2
3
4

wire-colour
blue
orange
not used

bus
(-)
(+)
shield
n.c.

referenz
A
B
S

.96

24,5

1.06

7/8 - 16 UN

27

~ 3.1

M00739

All drawings not scaled! All units in millimeter!

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

Ordering information
FOUNDATION fieldbus-H1 Junctions (IP 66 case)
NPJ130-NO
(856409)
PROFIBUS PA / FOUNDATION fieldbus-H1 T (one-way) junction,
IP 66 case, 3 x cable bushing,
incl. switchable bus termination

Catalog No.
9890102

NPJ460-NO
(856411)
PROFIBUS PA / FOUNDATION fieldbus-H1 four-way junction,
IP 66 case, 6 x cable bushing,
incl. switchable bus termination

9890104

NPJ130-EX
(856418)
PROFIBUS PA / FOUNDATION fieldbus-H1 T (one-way) junction,
IP 66 case, 3 x cable bushing,
for the Ex (Haz.) area

9890106

NPJ460-EX
(856420)
PROFIBUS PA / FOUNDATION fieldbus-H1 four-way junction,
IP 66 case, 6 x cable bushing,
for the Ex (Haz.) area

9890108

NPZ100-EX
(860619)
PROFIBUS PA / FOUNDATION fieldbus-H1 bus termination
for junction modules NPJ_ _0-EX, IP 66 case
for the Ex (Haz.) area

9890120

FOUNDATION fieldbus-H1 Connectors


NFE100-NE
(180884)
FOUNDATION fieldbus-H1 plug for cable, metal / plastic case, 7/8",
for the Ex (Haz.) and Non-Ex area

Catalog No.
3KDE636640L0101

NFE300-NE
(181248)
FOUNDATION fieldbus-H1 socket for cable, metal / plastic case, 7/8",
for the Ex (Haz.) and Non-Ex area

3KDE636640L0102

10

FOUNDATION fieldbus Junctions, Connectors, Accessories

10/63-6.60-EN

Ordering information
FOUNDATION fieldbus-H1 Junctions (IP 20 modules)
NGJ100-NE
Fieldbus device coupler: Trunk line module
For PROFIBUS PA / FOUNDATION fieldbus-H1.
For connecting the trunk line to the spur line modules,
incl. overvoltage protection to the trunk line,
supply voltage 10.6 / 16.7 up to 32 V DC,
rated current 4.5 A (trunk to trunk) / 1.0 A (trunk to spur)
IP 20, II 3G Ex nA IIC T4 Gc, for Ex/Haz. (Zone 2) and Non-Ex area,
incl. pluggable bus termination and DIN rail connector
Dimensions (L x W x H) 99.1 x 17.5 x 70.4 mm

Catalog No.
(2316048)

3KXN623100L0110

Fieldbus device coupler: Spur line module


For PROFIBUS PA / FOUNDATION fieldbus-H1.
2 channels, max. 12 modules per trunk line module, short circuit protection,
supply voltage 9.3 V DC, output (spur line) 45 mA (adjustable)
IP 20, II 3(3)G Ex nA [ic Gc] IIB T4 Gc, for Ex/Haz. (Zone 2) and Non-Ex area,
Dimensions (L x W x H) 89.7 x 17.5 x 70.4 mm

(2316051)

3KXN623100L0120

Fieldbus device coupler: Spur line module


intrinsically safe
For PROFIBUS PA / FOUNDATION fieldbus-H1.
1 channels, max. 12 modules per trunk line module, short circuit protection,
supply voltage 10.0 V DC, output (spur line) 35 mA (adjustable)
IP 20, II 3(1)GD Ex nA [ia Ga Da] IIC T4 Gc, for Ex/Haz. (Zone 2) and Non-Ex area,
Dimensions (L x W x H) 89.7 x 17.5 x 70.4 mm

(2316064)

3KXN623100L0130

11

ABB Automation GmbH


Service Instrumentation
Kallstadter Strae 1
68309 Mannheim, Germany
Customer service center: +49 (0)180 5 222 580*
E-Mail: automation.service@de.abb.com
www.abb.com
* 14 cents/minute from German landlines,
max. 42 cents/minute from mobiles.

Note
We reserve the right to make technical changes or
modify the contents of this document without prior
notice. With regard to purchase orders, the agreed
particulars shall prevail. ABB does not accept any
responsibility whatsoever for potential errors or
possible lack of information in this document.
We reserve all rights in this document and in the
subject matter and illustrations contained therein.
Any reproduction, disclosure to third parties or
utilization of its contents - in whole or in parts is
forbidden without prior written consent of ABB.
Copyright 2012 ABB
All rights reserved

3KXN660000R1001

Sales

Service

10/63-6.60-EN Rev. E 11.2012

Contact us

Anda mungkin juga menyukai