Anda di halaman 1dari 98

Contents

5 - Photo-electric sensors
OsiSense XU

Selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/2


b Multimode: Simpliity through innovation . . . . . . . . . . . . . . . . . . . . . . . . . page 5/12
b General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/14

OsiSense XU, general purpose


b Design 18
v Single mode function, metal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v Single mode function, plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v Multimode function, metal or plastic . . . . . . . . . . . . . . . . . . . . . . . . . .
b Miniature design
v Single mode function, plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v Multimode function, plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
b Compact design, 50 x 50
v Single mode function, plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v Multimode function, plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v Diffuse with adjustable background suppression . . . . . . . . . . . . . . . .
b Compact design, 92 x 77
v Single mode function, plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v Multimode function, plastic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v Diffuse with adjustable background suppression . . . . . . . . . . . . . . . .

page 5/26
page 5/28
page 5/30
page 5/32
page 5/36
page 5/38
page 5/40
page 5/42
page 5/44
page 5/46
page 5/48

OsiSense XU Application, fork and frame form


b Forks design
v Optical fork without adjustment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/50
v Optical fork with teach mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/52
v Optical fork with laser transmission and with teach mode . . . . . . . . . . page 5/54
v Ultrasonic fork, packaging series . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 5/56
v Optical fork with teach mode, packaging series . . . . . . . . . pages 5/58 and 5/60
v Optical fork with integral amplifier, mechanical handling series . . . . . page 5/62
b Frame design
v Dynamic detection of passage of objects, conveying series . . . . . . . . page 5/64

OsiSense XU Application, packaging series


b Detection of contrast
v Compact design 50 X 50 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v Fibre design, with teach mode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
v Compact design 81 X 58 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
b Luminescence sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
b Illumination sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
b For detection of transparent materials . . . . . . . . . . . . . . . . . . . . . . . . . .
b For detection of transparent materials, with teach mode . . . . . . . . . . . .
b For colour detection, sorting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
b For detection of water and aqueous liquids . . . . . . . . . . . . . . . . . . . . . .

page 5/66
page 5/68
page 5/70
page 5/72
page 5/74
page 5/76
page 5/78
page 5/80
page 5/84

OsiSense XU Application, food and beverage series


b Design 18, metal, stainless steel, multimode function . . . . . . . . . . . . . . page 5/86
b Design 18, stainless steel, single mode . . . . . . . . . . . . . . . . . . . . . . . . . page 5/88

10

5/0

Photo-electric sensors

Presentation,
dimensions,
schemes

OsiSense XU Application, packaging series

Compact design, 50 x 50
For colour detection
DC supply. Solid-state output

Presentation
Description
12

Detection zone and spot size

Detection curve
%
99
90

Object reflection

White
Yellow
light

72

123
OUT
SET

54

SEL

36

1
2
3
4
5

Dark blue
Black

18

Output LED
OUT1, OUT2 and OUT3 LEDs
Display (green, 4-digit)
SEL button (adjustment)
SET button

a (mm)
20

XUKC1pSMM12

(mm)
4

15
25
35
Detection distance (mm)

Detection distance related to objects degree of


reflection

Diagram

Accessories

SYNC passive = VDC, SYNC active = 0 V

Description

Diameter
mm
6.5

Pre-wired M12, 8-pin


connectors, shielded
cable (1)
Fixing bracket
(2 screws, 2 nuts and 2
washers included)

170 s
max.

335 s
max.

Dimensions

XUKC1pSMM12

Length
m
3

Reference
XSZ MCR03

Weight
kg
0.230

10

XSZ MCR10

0.715

XUZ K2000

0.040

Fixing bracket XUZ K2000

50
42

16,5

2 9
5

25

20

26,5

18x45

31,65

50

x5,1

42

50

2xx4,1

11,5

2xx4,4

M12

66

Wiring schemes

16

5,5

30

Wiring schemes
PNP output + synchro input

2
8

3
2

1
8

x5,3

Pre-wired connector XSZMCRpp

10

15

Sensor connector pin view

x4,3

NPN output + synchro input

2
3

5
8

5
7

Pin N
Type
Colour (2)
1

WH (white)
2
c 10...30 V
BN (brown)
3
Output 1
TAN (tan)
4
Output 2
YE (yellow)
5
Output 3
GY (grey)
6

PK (pink)
7
0V
VT (violet)
8
Synchro
RD (red)

Screening
TR (transparent)
(1) The use of shielded cable is recommended in order ensure correct operation of the sensor, especially in environments subject to electromagnetic interference.
(2) With pre-wired connector XSZ MCRpp.

5/81

9
10

Photo-electric sensors

References,
characteristics

OsiSense XU Application, packaging series


For colour detection (1)
DC supply. Solid-state output

Compact design and fibre design

1
2
3

System

Diffuse

Type of transmission

Red, blue and green

Nominal sensing distance (Sn)

4060 mm

4250 mm depending on fibre optics used (see page


5/83)

XURC3PPML2
XURC3NPML2
0.260

XURC4PPML2
XURC4NPML2
0.190

References

3-wire, PNP
3-wire, NPN
Weight (kg)

Characteristics

Product certifications
Ambient air temperature

5
6

8
9

Rated supply voltage


Voltage limits
Switching capacity (sealed)
Voltage drop, closed state

- 10+ 50 C
- 30+ 70 C
3585% RH (without condensation)
Amplitude 0.75 mm, f = 1055 Hz, 2 hours on the 3 axes
50 gn, 5 shocks on the 3 axes
IP67
IP65
Pre-cabled: diameter 5.4 mm, length 2 m, wire c.s.a.: 7 x 0.2 mm
Aluminium
Glass

Vinyl rubber sleeve


Polyacrylate
At 40 mm: 4 mm
Depending on fibre optics used: 2.58 mm (see page
5/83)
At 50 mm: 6 mm
At 60 mm: 8 mm
10000 Lux max.
3000 Lux max.
c 1224 V
c 1030 V (including ripple)
100 mA with overload and short-circuit protection
1.5 V

Current consumption, no-load


Switching time
Maximum switching frequency
Time delay

150 mA
Programmable by switch: 0.8 ms, 1.5 ms or 6 ms
1.2 kHz
Programmable by switch: 40 ms on falling edge

Function table for each channel (3 channels)


NO function
Output state (PNP or NPN) indicator
(illuminated when sensor output is ON)

Colour recognised
by sensor

Ambient humidity
Vibration resistance
Shock resistance
Degree of protection
Connection
Materials

For operation
For storage
Conforming to IEC60068-2-6
Conforming to IEC60068-2-27
Conforming to IEC60529
Case
Lenses
Cable
Cover

Spot diameter

Immunity to ambient light

NO function
NO function

Thru-beam or diffuse depending on fibres optics


selected

Sunlight
Halogen light

Colour not recognised


by sensor

(1) Applications: OsiSense XU Full colour is a colour sensor that can recognise up to 3 colours. It can be used to sort objects by colour or to monitor colours, and is
insensitive to surface finishes (matt or reflective), as well as ambient lighting. The sensor is suitable for use in many industrial sectors, such as packaging
machines, printing machines, etc.

10

5/82

Photo-electric sensors

Presentation,
dimensions,
mounting,
schemes

OsiSense XU Application, packaging series

For colour detection


DC supply. Solid-state output

Presentation

OUT

SET
2 3 4

C
B
C SET

S
RUN

FAST T-ON
(40ms)

EXT

C+I
5
A

N
INT

SLOW

T-OFF

Ext. synchro
signal
Output ON
OFF

40ms

Dimensions
XURC3pPML2

Same colour
Different colour

XURC4pPML2

50

(1)

82,4

16

(2)

30

80

22

(3)
37

(1)

25

68

Mounting rail fixing

25

44

42

(1) Mounting on rail


(2) Fibre optic clamp
(3) 1 elongated hole 4.4 x 5.4
(4) 2 elongated holes 4.4 x 6.4

(4)

15

(1) 2 holes for M5 screws, depth 10 mm

Mounting

Installation precautions

15

Figure 1

Figure 2

15

Figure 1

Figure 2

2
3

40ms

R = response time

6 Response time mode selector


v Fast mode (F), normal mode (N) or slow
mode (S).

detected

Object
detected

Ext. synchro
signal
Output ON R
OFF

C or C + I selector
7 Output time delay selector
(T-ON/T-OFF)
v Mode C: this mode is used for the
v Output time delay, internal synchronisation
detection of different coloured objects.
v Mode C + I: in this mode the sensor is
mode
insensitive to varying surface finishes of the
Object
object.
detected
Synchronisation mode selector
Output ON
v Internal synchronisation mode (INT): in
OFF
40 ms
40 ms
this mode, colour detection is performed
continually.
v
Output
time
delay,
external
synchronisation
v External synchronisation mode (EXT): in
mode
this mode, colour detection is synchronised
with an external signal.
Object

4
1 Operational status LED
2 Teach mode button, for
memorising reference colours
3 Reference colours and operating
mode selector
v Selection of reference colours
(SET)
5
v Selection of operating mode:
- TOLERANCE mode (positions
15): 5 positions allow selection of
the tolerance level to be applied to
the shading of the colour to be
detected.
- RUN mode (position S): this mode
enables sorting by colour.

Suitable fibre optics. For further information, see pages 5/118 to 5/121.
To obtain
b
optimal detection of the
colours, it is
recommended that the
sensor be positioned
such that the
transmitted light beams
strikes the object at an
angle of 15 from its
vertical axis (figure 1).
The direction
b
of travel of the object
must be as shown in
figure 2. This provides
detection that is less
sensitive to variations in
the angle of detection.

Type of
fibre
Focused

System

Reference

Sensing
distance (mm)
Diffuse
XUFN5L01L2
10
20
XUFN5L02L2
30
XUFN5L03L2
Standard
Diffuse
XUFN05321
5
4
XUFS0520
XUF N02323 + XUFZ06 7
Thru-beam XUFN12301 + XUFZ01 250
(1)
XUFS2020 + XUFZ01 150
(1) Detection of colour by transparency

Diameter of spot
(mm)
2.5
5
8

0.5

7
8

Cable connections
BN
BU
PK

(brown)
(blue)
(pink)

VI
BK
WH
GR

(violet)
(black)
(white)
(grey)

+ Supply (1224 V)
SET signal (remote activation of teach mode to memorise
reference colours)
EXT signal (external synchronisation)
Output A
Output B
Output C

Wiring scheme
PNP

NPN
BN
PK
VI
BK
WH
GY
BU

BN
BK
WH
GY
PK
VI

BU

10

5/83

Photo-electric sensors

References,
characteristics

OsiSense XU Application, packaging series


Thru-beam system for detection of water
and aqueous liquids

Miniature design

1
2
3

System

Thru-beam

Type of transmission

Infrared (transmission frequency = 1450 nm)

Nominal sensing distance (Sn)

50 m (use between 10 and 20 cm, see applications)

References

4
5

XUMW1KSNL2 (1)

3-wire, PNP and NPN


NO or NC programmable function
Weight (kg)

0.155

Characteristics
Product certifications

Ambient air temperature

For operation: 0+ 40 C. For storage: - 5+ 50 C

Vibration resistance

Conforming to IEC60068-2-6

25 gn, amplitude 2 mm (f = 1055 Hz)

Shock resistance

Conforming to IEC60068-2-27

30 gn, duration 11 ms

Degree of protection

Conforming to IEC60529

IP65

Connection

Materials

Pre-cabled, diameter 4 mm, length 2 m, wire c.s.a.: 2 x 0.2 mm2 (transmitter)


or 4 x 0.2 mm2 (receiver)
Case: PBT, lenses: polycarbonate, cable: PUR

Rated supply voltage

c 10.826.4 V with protection against reverse polarity

Voltage limits

c 1030 V (including ripple)

Solid-state digital output

Switching capacity (sealed)


Voltage drop, closed state
Maximum switching frequency

y 100 mA with overload and short-circuit protection


y2V
1 kHz

Delays

First-up: y 50 ms; response: y 0.5 ms; recovery: y 0.5 ms

Current consumption, no-load


Indicator lights

y 45 mA (transmitter + receiver)
Transmitter
Receiver

Green LED, supply on


Yellow LED: solid-state output (LED on, output on)
Green LED: stability (see diagram on page 5/85)

(1) Reference for both transmitter and receiver for thru-beam system.
(2) Application examples: detection of the level of aqueous liquids in any transparent or almost opaque container, and any product containing water molecules
(adhesives, ice creams, damp fabrics, etc.).
d

d
Osiris

d = 10 cm

10

Transparent containers

5/84

d = 20 cm

d = 5 cm
Almost opaque containers

d = 10 cm

Photo-electric sensors

Curves,
dimensions,
schemes

OsiSense XU Application, packaging series

Thru-beam system for detection of water


and aqueous liquids

Transmission curves
Absorption level (%)

Detection principle

Beam
intensity

0
2
3

20
1
40

60

The wavelength of the transmitted beam corresponds to the


maximum absorption frequency of water molecules.

80

100
500

1
2
3

Excess gain curve

1000

1700
1500
1450
Transmission wavelength (nm)

1100

Transmission curve of a standard photo-electric sensor


Transmission curve of sensor XUMW1KSNL2
Curve of water absorption against incident beam wavelength

Stability curve

Functions

Signal 10
level
2

Gain
4

10

1,25
1
0,75

103
500
200
100
50

Output
Yellow LED

On
Off

Stability
Green LED

On
Off

20
10
5

LED
1 Yellow LED, output
2 Green LED, stability
Potentiometer
3 Sensitivity adjustment
Switch
4 NO/NC programming
NO: detection of object
NC: detection of object absence

2
1
0,1

0,2

0,5

10

20

5
6

50 100
D (m)

Dimensions
Bracket fixing
15

10

(2)

20

M3
32

23

16

10

2,5

(3)

3,2

13

20

(1)

5,6

11,5

1,5

41

(4)
3

32

(1) Output LED.


(2) Output LED and stability LED.
(3) 2 holes 3.2.
(4) Locknut plate.

Wiring schemes (3-wire c)


Transmitter

BK Receiver. PNP output


WH Receiver. NPN output
WH

BN (+)
BU (-)

10

/
/

5/85

Photo-electric sensors

References

OsiSense XU Application, multimode


food and beverage processing series
Design 18, metal, stainless steel
Three-wire DC, solid-state output

550055

18 stainless steel

Pre-cabled (1)

Sensing distance Function


(Sn) (2) m
015
NO or NC, by
depending on
programming
whether
accessories are used

XUB0pppNL2

550002

015
NO or NC,
PNP
depending on
by programming
whether accessories
are used
NPN

Reference
XUB0SPSNL2

Weight
kg
0.105

XUB0SPSWL2 (3)

0.110

XUB0SNSNL2

0.105

XUB0SNSWL2 (3)

0.110

Along case
axis
90 to case
axis
Along case
axis
90 to case
axis

XUB0SPSNM12

0.055

XUB0SPSWM12 (3)

0.060

XUB0SNSNM12

0.055

XUB0SNSWM12 (3)

0.060

Accessories

XUB0pppNM12

Description
Thru-beam accessories
(transmitter)

550000

Line of
sight
Along case
axis
90 to case
axis
Along case
axis
90 to case
axis

M12 connector

XUB0pppWL2

PNP

NPN

550001

Output

5
XUB0pppWM12
805799

Reflector 50 x 50 mm

Connection
Pre-cabled
(1)

Line of
sight
Along case
axis
90 to case
axis
M12
Along case
connector axis
90 to case
axis

Reference
XUB0SKSNL2T

Weight
kg
0.105

XUB0SKSWL2T (3)

0.110

XUB0SKSNM12T

0.055

XUB0SKSWM12T (3)

0.060

XUZC50

0.020

Fixing accessories (4)


Description

Reference

Stainless steel fixing bracket

XUZA118

Weight
kg
0.045

Plastic fixing bracket with adjustable ball-joint

XUZA218

0.035

Plastic fixing clamp, 24.1 mm centres


with locking screw

XUZB2005

0.007

805817

805818

XUZC50

503663

XUZA118

XUZB2005

9
10

5/86

XUZA218

(1) For a 5 m long cable, replace L2 by L5.


Example: XUB0SPSNL2 becomes XUB0SPSNL5.
(2) For further information, see page 5/87.
(3) For line of sight 90 to case axis versions, see sensing distances on page 5/87.
(4) For further information, see page 5/158.

Characteristics, schemes,
curves,
dimensions

Photo-electric sensors

OsiSense XU Application, multimode


food and beverage processing series

Design 18, metal, stainless steel


Three-wire DC, solid-state output

Characteristics
Sensor type
Product certifications
Connection

Connector
Pre-cabled

Sensing distance
nominal Sn
/ maximum
(excess gain = 2) (excess gain = 1)

Type of transmission
Degree of protection
Storage temperature
Operating temperature
Materials
Vibration resistance
Shock resistance
Indicator lights

Conforming to IEC60068-2-6
Conforming to IEC60068-2-27
Output state
Supply on
Stability

Rated supply voltage


Voltage limits (including ripple)
Current consumption, no-load
Switching capacity
Voltage drop, closed state
Maximum switching frequency
Delays
First-up
Response
Recovery

Wiring schemes
M12 connector

3 (-)
1 (+)
4 OUT/Output
2 Beam break
1
2
input (1)
See connection on page 9/44.
4

Pre-cabled
(-) BU (Blue)
(+) BN (Brown)
OUT/Output BK (Black)
Beam break input (1)
VI (Violet)

XUB0ppppM12, XUB0ppppM12T
XUB0ppppL2, XUB0ppppL2T
UL, CSA, e
M12

Length: 2 m
Line of sight
Line of sight 90 to case Accessory
along case axis axis
m
0.12 / 0.12
0.11 / 0.11
Without (diffuse with background
suppression)
m
0.3 / 0.4
0.2 / 0.3
Without (diffuse)
m
2/3
1.5 / 2
With reflector (polarised reflex)
m
15 / 20
10 / 14
With thru-beam accessory (thru-beam)
Infrared, except polarised reflex (red)
IP 65, IP 67 conforming to IEC 60529; IP 69K conforming to DIN 40050; double insulation i
C - 40+ 70
C - 25+ 55
Case: stainless steel, grade 304CU; Lens: PMMA; Cable: PvR
7 gn, amplitude 1.5 mm (f = 10 to 55 Hz)
30 gn, duration 11 ms
Yellow LED (transmission present for XUB0ppppppT)
Green LED
Red LED (except for XUB0ppppppT)
V
c 1224 with protection against reverse polarity
V
c 1036
mA 35 (20 for XUB0ppppppT)
mA 100 with overload and short-circuit protection
V
1.5
Hz 250
ms < 200
ms < 2
ms < 2

PNP
BN/1
PNP

NPN

BN/1
NPN

BK/4

BU/3

1
2
3
4
5

Thru-beam accessory

1/BN
2/VI
3/BU

BK/4

BU/3

Input 2/VI:
- not connected: beam made
- connected to : beam broken

Detection curves (line of sight along case axis)


With thru-beam accessory (thru-beam)

15

Without accessory
(diffuse)

Without accessory (diffuse


with bckgrnd. suppression

10

15

40

20 m

12 cm

-2
-4
-6

12 cm

30 cm

Object: 10 x 10 cm, 1: white 90%, 2: grey 18%


Variation of usable sensing distance Su (without accessory, with adjustable background suppression)
Teach mode at minimum
Teach mode at maximum
A-B: object reflection
B
B
coefficient
Black 6%
Grey 18%
White 90%
Sensing range
Non sensing zone
(matt surfaces)
A
A 1
9 12 17
S (cm)
8 10

6
4
2

12 mm

-15

With reflector
(polarised reflex)

3m
2
2

With reflector XUZC50

8
9

S (cm)

Dimensions
XUB

Pre-cabled (mm)
b
a

a
18, line of sight along case axis 64 (2)
18, line of sight 90 to case axis 78

Connector (mm)
b
44
44

a
78 (2)
92

10

b
44
44

(1) Beam break input on thru-beam transmitter only.


(2) For XUB0ppppppT, 64 becomes 62 mm and 78 becomes 76 mm.

5/87

Photo-electric sensors

References,
characteristics

OsiSense XU Application, single mode


food and beverage processing series
Stainless steel case M18 x 1
DC. Solid-state output

Design 18

2
3
4

System

Thru-beam 1

Reflex 2

Polarised reflex 2

Diffuse 3

Type of transmission

Infrared

Infrared

Red

Infrared

Sensing
distance

Nominal Sn (excess gain = 2)

15 m

4m

2m

0.10 m

Maximum (excess gain = 1)

20 m

5.5 m (with
50x50mm reflector)

3 m (with 50 x 50 mm
reflector)

0.15 m

XU2N18PP341 (2)

XU1N18PP341 (3)

XU9N18PP341 (3)

XU5N18PP341

XU2N18PP341W (2)

XU1N18PP341W (3)

XU9N18PP341W (3)

XU5N18PP341W

XU2N18NP341 (2)

XU1N18NP341 (3)

XU9N18NP341 (3)

XU5N18NP341

XU2N18NP341W (2)

XU1N18NP341W (3)

XU9N18NP341W (3)

XU5N18NP341W

0.270

0.155

0.155

0.135

XU2N18PP341D (2)

XU1N18PP341D (3)

XU9N18PP341D (3)

XU5N18PP341D

XU2N18PP341WD
(2)
XU2N18NP341D (2)

XU1N18PP341WD
(3)
XU1N18NP341D (3)

XU9N18PP341WD
(3)
XU9N18NP341D (3)

XU5N18PP341WD

XU2N18NP341WD
(2)
0.130

XU1N18NP341WD
(3)
0.085

XU9N18NP341WD
(3)
0.085

References of pre-cabled versions (1)


3-wire, PNP
NO or NC programmable function

3-wire, NPN
NO or NC programmable function

Line of sight along case


axis
Line of sight 90 to
case axis
Line of sight along case
axis
Line of sight 90 to
case axis

Weight (kg)

References of connector versions


3-wire, PNP
NO or NC programmable function

3-wire, NPN
NO or NC programmable function

Line of sight along case


axis
Line of sight 90 to
case axis
Line of sight along case
axis
Line of sight 90 to
case axis

Weight (kg)

XU5N18NP341D
XU5N18NP341WD
0.065

(1) Sensors available with 5 m long cable: To order, add L5 to the end of the reference selected from above.
Example: sensor XU1N18PP341 with 5 m cable becomes XU1N18PP341L5.
(2) Reference for both transmitter and receiver for thru-beam system sensors.
(3) 50 x 50 mm reflector included with reflex system sensors.

References of fixing accessories


Description

8
9
10
Accessories:
page 5/158

5/88

Reference

Stainless steel fixing bracket

XUZA118

Weight
kg
0.045

Plastic fixing bracket

XUZA218

0.035

Set of 2 stainless steel nuts

XSZE318

0.020

Set of 2 plastic nuts

XSZE218

0.004

Photo-electric sensors

Characteristics,
curves

OsiSense XU Application, single mode

food and beverage processing series


Stainless steel case M18 x 1
DC. Solid-state output

Characteristics
Product certifications
Ambient air temperature
Vibration resistance
Shock resistance
Degree of protection
Connection

e, UL, CSA
For operation: - 25...0+ 55 C. For storage: - 40...+ 70 C
Conforming to IEC60068-2-6
25 gn, amplitude 1.5 mm (f = 1055 Hz)
Conforming to IEC60068-2-27 30 gn, duration 11 ms
Conforming to IEC60529
IP67
Pre-cabled
Pre-cabled, diameter 4.2 mm, length 2 m (3), wire c.s.a.: 4 x 0.34 mm2
Connector
M12 male connector, 4-pin (suitable female connectors, including pre-wired versions, see page
9/44)
Materials
Case
Food and beverage processing stainless steel, grade 304 Cu
Lenses
PMMA
Cable
PvR
Rated supply voltage
c 1224 with protection against reverse polarity
Voltage limits
c 1030 V (including ripple)
Switching capacity (sealed)
y 100 mA with overload and short-circuit protection
Voltage drop, closed state
1.5 V
Current consumption, no-load
30 mA (reflex and diffuse), 50 mA (thru-beam)
Maximum switching frequency
500 Hz
Delays
First-up
15 ms
Response
1 ms
Recovery
1 ms
Indicator lights
Supply on
Green LED, on transmitter only
Output state
Yellow LED, on receiver only
(1) Sensors available with 5 m long cable: To order, add L5 to the end of the reference selected from above.
Example: sensor XU1N18PP341 with 5 m cable becomes XU1N18PP341L5.

1
2
3
4

Curves

Detection curves
Thru-beam system

Reflex system with


reflector XUZC50

of beam
cm

15

of beam
cm
10

12 mm
10

E/R 4

15

-4

-15

Polarised reflex system


with reflector XUZC50

Diffuse system

of beam
cm
6
4
E/R 2

of beam
cm
E/R 1,4
1

-2
-4
-6

-10

Excess gain curves (ambient temperature: + 25 C)


Thru-beam system

Gain
100
80
50

0,2

5
2

1
15 cm

-1
-1,4

Object 10 x 10 cm
1 White 90% 2 Grey 18%
Reflex system with reflector XUZC50
Gain
100

20

30
20

10

10
8
5

3
2
1
1

3 4 5 6 8 10 15 20 30 50
D (m)

Polarised reflex system with reflector XUZC50

0,1
0,1

8
0,2

0,5

45

10
D (m)

Diffuse system

Gain
10

Gain

50
30
20
15
10
7
5

3
2
0,1
0,1

0,5

3
5
D (m)

1
0,1 0,2 0,5 1

10 20

60
D (cm)

10

Object 10 x 10 cm
White 90%

Accessories:
page 5/158

5/89

Photo-electric sensors

Dimensions

OsiSense XU Application, single mode


food and beverage processing series
Stainless steel case M18 x 1
DC. Solid-state output

Dimensions

XUpN18pp341

2
3

M18x1

XUpN18pp341W

(1)

50

24

78

XUpN18pp341D

M18x1

(1)

50

24

62 (2)

M18x1

XUpN18pp341WD

(1)

M18x1

(1)

4
50
62
72

5
6

(1) LED
(2) 64 for XU9N18pp341
Fixing nut tightening torque: < 15 N.m
Connector tightening torque: 2 N.m

7
8
9
10
Accessories:
page 5/158

5/90

24

50
62
88

24

Photo-electric sensors

Schemes

OsiSense XU Application, single mode

food and beverage processing series


Stainless steel case M18 x 1
DC. Solid-state output
Wiring schemes
M12 connector

Pre-cabled

3 ()
1 (+)
4 OUT/Output
2 Prog (or beam break input
for thru-beam transmitter only)

() BU (Blue)
(+) BN (Brown)
(Out/Output) BK (Black)
(Prog) OG (Orange)
(Beam break input) VI (Violet) on thru-beam transmitter only

See connection on page 9/44.

Wiring schemes - diffuse


PNP NO

PNP NC

NPN NO

OG/2

NPN NC

Transmitter

OG/2

BN/1

BN/1

BK/4
BU/3

BK/4
BU/3

BN/1
BK/4

BN/1
BK/4

BU/3

BU/3

OG/2

1/BN
2/VI
3/BU

OG/2

Wiring schemes - reflex and thru-beam


PNP NO

PNP NC

NPN NO

NPN NC

BN/1

BK/4
BU/3

BK/4
BU/3

OG/2

OG/2

BN/1

OG/2

BN/1
BK/4

BN/1
BK/4

BU/3

BU/3

OG/2

Beam break input on thru-beam transmitter only


Beam made

Beam broken
BN/1

VI/2

BU/3

BN/1

VI/2

BU/3

7
8
9
10
Accessories:
page 5/158

5/91

References,
characteristics

Photo-electric sensors

OsiSense XU Application, assembly series


Metal case, cylindrical, threaded M8 x 1
DC supply. Solid-state output

Design 8

501337_1

System
Type of transmission

Thru-beam
Infrared

Thru-beam
Infrared

Diffuse
Infrared

Diffuse
Infrared

Nominal sensing distance (Sn)

2m

2m

0.05 m

0.05 m

Connection

Pre-cabled
Connector

References

3
4
5
6
7
8

3-wire, PNP

NO function
NC function

XUAH0214
XUAH0224

XUAH0214S
XUAH0224S

XUAH0515
XUAH0525

XUAH0515S
XUAH0525S

3-wire, NPN

NO function
NC function

XUAJ0214
XUAJ0224

XUAJ0214S
XUAJ0224S

XUAJ0515
XUAJ0525

XUAJ0515S
XUAJ0525S

XUAH0203
0.050

XUAH0203S
0.015

0.50

0.015

Transmitter
Weight (kg)

Characteristics
Product certifications
Ambient air temperature

For operation
For storage

e, cULus
- 25+ 55 C
- 30+ 70 C

Vibration resistance

Conforming to IEC60068-2-6

7 gn, amplitude 1 mm (f = 1055 Hz)

Shock resistance

Conforming to IEC60068-2-27

30 gn, duration 11 ms

Degree of protection

Conforming to IEC60529

IP 67 - IP 65

Connection

Pre-cabled
Connector

3.5 mm, length 2 m, wire c.s.a.: 3 x 0.14 mm


M8 female connectors, 3-pin, see page 9/44

Materials

Case
Cable
Lenses

Nickel plated brass


PvR
PMMA

IP65

IP 67 - IP 65

IP65

PvR

Rated supply voltage

c 1224 V with protection against reverse polarity

Voltage limits (including ripple)

c 1030 V

Switching capacity (sealed)

y 100 mA with overload and short-circuit protection

Voltage drop, closed state

y1V

Current consumption, no-load Transmitter


Receiver
Diffuse

y 15 mA
y 10 mA
y 25 mA

Maximum switching frequency

2000 Hz

1000 Hz

First-up
Response and recovery

y 20 ms
y 0.25 ms

y 0.5 ms

Function

Diffuse or through beam system


No object present in the beam

Object present in the beam

Delays

501336_1

501335_1

501335_1

Function table

Output state (PNP or NPN)


NO
indicator: yellow LED
(illuminated when sensor output
NC
is ON)

10
Accessories:
page 5/158

5/92

Photo-electric sensors

Curves,
dimensions,
schemes

OsiSense XU Application, assembly series

Metal case, cylindrical, threaded M8 x 1


DC supply. Solid-state output

Curves

Detection curves
Thru-beam system

Diffuse system

15
5
2

-5

5 cm

-0,5
-1

-10
-15

Object 5 x 5 cm; 1 White 90%; 2 Grey 18%

1
0,5

10

Excess gain curves (ambient temperature: 25 C)


Thru-beam system

Diffuse system

Variation of sensing distance Sn


Gain

Gain
40

500
300

100
80

20
15
10
9

100
50

60
40
20

10

5
1

0,1

0,1 0,2 0,5 1


0,3 0,8

3 6 10
5 D (m)

0,2

5 8 10
4 6 9
D (cm)

0,4 0,8 2
0,6 1

8 10 12 14 16
C (cm)

C Side of square object



White

Grey

Detection differential (H) when object approaches from the


front: H y 25% of Sn

Object 5 x 5 cm, White 90%

Dimensions
XUA

XUApppppS

M8 connector
4
1

M8x1
4

(1)

(1)
4

13

18

1+
34 OUT or test

13

21

M8x1
47

48
(1) LED, 4 viewing ports at 90.

(1) LED, 4 viewing ports at


90.

Wiring schemes (3-wire c)

Note: fixing nut tightening


torque: < 2 N.m

See connection on
page9/44

XUA

Transmitter

PNP
BN/1

BN/1

BU/3

BK/4
BU/3

VI/4

Beam break test

NPN
BN/1
BK/4
BU/3

8
For thru-beam transmitter XUAH0203 only

For thru-beam transmitter XUAH0203S only

BN +

BN +

VI

VI

BU

BU

Beam made
LED on (steady light)

Beam broken
LED flashing

+
1

+
1

Beam made
LED on (steady light)

Beam broken
LED flashing

10
Accessories:
page 5/158

5/93

Photo-electric sensors

References,
dimensions

OsiSense XU Application

Conveying and access control series


Miniature design
Four-wire DC, solid-state output
Diffuse system with background suppression
Sensing dist. Function
(Sn) m

0.0150.08

NO/NC
depending
on wiring

Output

Connection

PNP

Pre-cabled (L = 2 m) XUY PS989SP


M8 connector

NPN

Reference

XUY PSCO989SP

Pre-cabled (L = 2 m) XUY PS989SN


M8 connector

XUY PSCO989SN

Weight
kg
0.075
0.044
0.075
0.044

Diffuse system with adjustable sensitivity

Sensing dist. Function


(Sn) m
0.030.25
XUY PS989Sp

NO/NC
depending
on wiring

Output

Connection

PNP

Pre-cabled (L = 2 m) XUY P989SP


M8 connector

NPN

Reference

XUY PCO989SP

Pre-cabled (L = 2 m) XUY P989SN


M8 connector

XUY PCO989SN

Weight
kg
0.075
0.044
0.075
0.044

Polarised reflex system

Sensing dist. Function


(Sn) m
1
with
50 x 50 mm
reflector

NO/NC
depending
on wiring

Output Connection
PNP

Pre-cabled (L = 2 m) XUY B989SP (1)


M8 connector

NPN

Reference

XUY BCO989SP (1)

Pre-cabled (L = 2 m) XUY B989SN (1)


M8 connector

XUY BCO989SN (1)

Weight
kg
0.093
0.061
0.093
0.061

(1) 50 x 50 mm reflector (XUY1111) and multi-adjustment fixing bracket included with sensor.

Accessory

For use with

Reflector, 50 x 50 mm
XUY B989Sp

Sensing dist. Function


(Sn) m

XUY1111

XUY B989Sp

XUY1111

Output Connection

Reference

4 (Transmitter)

Pre-cabled (L = 2 m) XUY E989

4 (Receiver)

NO/NC
depending
on wiring

PNP

0.044
0.075

Dimensions
XUY PS989Sp

XUY1111
10

13,5

(2)

(1)

2x3,1
2,5

14,5

60

3 9,5

2,8

2x3,1

XUY p989Sp
Transmitter/Receiver
13,5

3 9,5
2,5

5/94

(2)

40

(1)

10

8
10

2x3,1

50

40

32

(1)

0.044

Applications:
Monitoring position or presence of parts, with background suppression
Detection of height of objects on a conveyor
Detection of product, pellet, powder levels.

XUY E989 and XUY R989pp


20

XUY RCO989SN

0.044
0.075

10

XUY RCO989SP

Pre-cabled (L = 2 m) XUY R989SN


M8 connector

b
v
v
v

0.075

Pre-cabled (L = 2 m) XUY R989SP


M8 connector

NPN

Weight
kg

XUY ECO989

M8 connector

13

0.018

Thru-beam system

(1) Optical axis


(2) Accuracy adjustment

Photo-electric sensors

Characteristics,
schemes

OsiSense XU Application

Conveying and access control series


Miniature design
Four-wire DC, solid-state output

Characteristics

Sensor type

XUY ppppp

XUY pCOppppp

Product certifications
Connection

e, cULus (1)
Connector

M8, 4-pin, on 0.2 m flying lead


Pre-cabled
Length: 2 m

Nominal sensing distance


m
0.08 diffuse with background suppression
(Sn)
m
0.25 diffuse with adjustable sensitivity
m
1 polarised reflex (with 50 x 50 mm reflector)
m
4 thru-beam
Type of transmission
LED
Red, pulsed
Modulation frequency
6 kHz (4 kHz for XUY PSpp989Sp)
Degree of protection
Conforming to IEC60529
IP 65 and IP 67
Ambient air temperature
For storage
C
- 20...+ 80
For operation
C
0...+ 50
Materials
Case
ABS
Lens
PMMA
Cable
PVC
PUR
Immunity to ambient light Natural light
Lux
10 000 (insensitive for XUY PSpp989Sp)
Incandescent bulb
Lux
5000 (insensitive for XUY PSpp989Sp)
Rated supply voltage
V
c 12...24 with protection against reverse polarity
Voltage limits (including ripple)
V
c 10...30
Current consumption, no-load
mA
< 25
Switching capacity per output
mA
100 with overload and short-circuit protection
Voltage drop, closed state
V
At 100 mA: < 2; at 10 mA: < 1
Maximum switching frequency
Hz
500
Delays
Response and recovery
ms
1
(1) This product is UL Listed if supplied by a class II or isolated supply delivering c 30 V max. (isolated transformer for example) and protected by a UL fuse rated
at 3 A max.

Wiring scheme - connector

Wiring scheme - pre-cabled

M8

Pin n - colour

1 BN: Brown

PNP output

2 WH: White

NO

4
3

3 BU: Blue

Diffuse

4 BK: Black

Transmitter
BN
BK

NC

c 10-30 V
BN

WH

Nc

BU

0V

NO

BK

BK

WH
BU

WH
BU

WH
BU

0V

0V

Access control

NO

c 10-30 V
BN
WH
BK

NC

c 10-30 V
BN
WH
BK

0V

Monitoring metal rods

BU

NC

WH
BU

0V

c 10-30 V
BN
WH

BU

BK

NO

BK
0V

c 10-30 V
BN

0V

NPN output

BU

Application examples

c 10-30 V
BN

BK

NPN output
c 10-30 V Nc: Not connected
Nc

NC

Polarised reflex and thru-beam


PNP output

c 10-30 V
BN

c 10-30 V
BN
WH
BK

0V

BU

0V

Detection of tin cans on a conveyor

8
9
10

5/95

Photo-electric sensors

References

OsiSense XU Application, packaging and


machine tool series

567541

Miniature design, metal


Three-wire DC, solid-state output
Sensing distance Function
(Sn)

Output Connection

Diffuse system with adjustable sensitivity

0.77 m

PNP

Pre-cabled (L = 2 m)

XUM5BPANL2

0.128

Pre-cabled (L = 2 m)

XUM5BNANL2

0.128

PNP

Pre-cabled (L = 2 m)

XUM5BPBNL2

0.128

NPN

Pre-cabled (L = 2 m)

XUM5BNBNL2

0.128

PNP

Pre-cabled (L = 2 m)

XUM9BPANL2

0.128

NPN

Pre-cabled (L = 2 m)

XUM9BNANL2

0.128

PNP

Pre-cabled (L = 2 m)

XUM9BPBNL2

0.128

NPN

Pre-cabled (L = 2 m)

XUM9BNBNL2

0.128

Universal reflector 50 x 50 mm

XUZC50

0.020

Lateral reflector 8.6 x 29.5 mm

XUZ C08

0.006

XUM 5BppNL2

Polarised reflex system

567543

567542

5 m with
reflector XUZC50
2 m with
reflector XUZC08

NO
NC

Reflectors

XUZ C08

XUZC50

Thru-beam system (transmitter + receiver)

15 m

NO

NC

PNP

Pre-cabled (L = 2 m)

XUM2BPANL2

0.237

NPN

Pre-cabled (L = 2 m)

XUM2BNANL2

0.237

PNP

Pre-cabled (L = 2 m)

XUM2BPBNL2

0.237

NPN

Pre-cabled (L = 2 m)

XUM2BNBNL2

0.237

Pre-cabled (L = 2 m)

XUM2BKCNL2T

0.128

Transmitter only

524752

524751

Weight
kg

NPN

NO

NC

Reference

15 m

Receiver only
15 m

NO
NC

XUM 2B2KCL2T

Fixing accessory

Description

567546

XUM 2BppNL2R

Base mounting fixing bracket

7
XUZAM81

8
9
10

5/96

PNP

Pre-cabled (L = 2 m)

XUM2BPANL2R

0.128

NPN

Pre-cabled (L = 2 m)

XUM2BNANL2R

0.128

PNP

Pre-cabled (L = 2 m)

XUM2BPBNL2R

0.128

NPN

Pre-cabled (L = 2 m)

XUM2BNBNL2R

0.128

Reference
XUZAM81

Weight
kg
0.020

Characteristics,
schemes,
curves

Photo-electric sensors

OsiSense XU Application, packaging and


machine tool series
Miniature design, metal
Three-wire DC, solid-state output

Characteristics
Sensor type
Product certifications
Connection
Pre-cabled
Sensing distance
nominal Sn /
maximum
(excess gain = 2) (excess gain = 1)
Type of transmission
Degree of protection
Storage temperature
Operating temperature
Materials

Vibration resistance
Shock resistance
Indicator lights

XUMpBppNL2
e, cULus, CTick
Length: 2 m
0.77 diffuse system with adjustable sensitivity
5 polarised reflex
15 thru-beam
Infrared, except polarised reflex system (red)
IP 65, IP 67
IP 69K
- 40+ 70
- 30+ 60
Zamack and stainless steel
Glass

PVC (black for transmitter, grey for other


versions)
10 to 55 Hz, amplitude 1.5 mm, 2 hours in each direction X, Y and Z
500 m/s2 10 x in each direction X, Y and Z
Orange LED (excluding transmitter)
Green LED
Orange LED: supply on
Red LED: light received; green LED: supply on
c 12...24 with protection against reverse polarity
c 1030
16 for XUM 5; 13 for XUM9; 11 for transmitter XUM2; 13 for receiver XUM2
y 100 with overload and short-circuit protection
y3
1000
< 100
0.5
0.5

m
m
m

Conforming to IEC60529
DIN 40050
C
C
Case
Lens
Cable
Conforming to IEC60068-2-6
Conforming to IEC60068-2-27
Output state
Stability
Transmitter
Receiver

Rated supply voltage


Voltage limits (including ripple)
Current consumption, no-load
Switching capacity
Voltage drop, closed state
Maximum switching frequency
Delays
First-up
Response
Recovery

Wiring schemes
Pre-cabled

V
V
mA
mA
V
Hz
ms
ms
ms

PNP

(-) BU (Blue)
(+) BN (Brown)
OUT/Output BK (Black)

NPN

BN/1
PNP

BK/4 (NO,NC)

BU/3

Curves

1
0,5
0
-0,5

-2

10
8
6
4
2
0
-2
-6
-8

-1,5

-10
0

0,5
Vertical movement
Horizontal movement

1
Distance (m)

-12

1
2
XUZ C08
XUZ C50

4
5
6

3/BU

Thru-beam

12

-4

-1

1/BN

BK/4 (NO,NC)

Parallel movement (cm)

1,5

Transmitter c

BU/3

Polarised reflex

Parallel movement (cm)

Parallel movement (cm)

Diffuse

BN/1
NPN

6
7
8
Distance (m)

40
35
30
25
20
15
10
5
0
-5
-10
-15
-20
-25
-30
-35
-40

7
8
0

10

15
20
Distance (m)

9
10

5/97

Photo-electric sensors

Dimensions

OsiSense XU Application, packaging and


machine tool series
Miniature design, metal
Three-wire DC, solid-state output

Diffuse system

Description - XUM 5BppNL2

Dimensions - XUM 5BppNL2

(3)
0.35

29.5
(1)

7.1

20

36.8

3.8

4.2 L = 2 m

3.8

40.8

(2)

16.2

19.8

(1)

MIN MAX

2xM3

4.2

(1) Output state LED.


(2) Stability and power on LED.
(3) Adjustment potentiometer.

(1) Potentiometer.
R: Reception, T: Transmission.

Polarised reflex system


Description - XUM 9BppNL2

Dimensions - XUM 9BppNL2


16.2

29.5

4.2 L = 2 m

19.8

20

(2)

36.8

40.8

7.1

0.35

(1)

2xM3

Dimensions - XUM 2BKCNL2T

8
9
10

5/98

19.8
20

36.8

2xM3

4.2

(1)

4.2

4.2 L = 2 m

(1) Output state LED.


(2) Stability and power on LED.

2xM3

Description - XUM 2BppNL2R

(2)

40.8

19.8
20

(1) Output state LED.

T: Transmission.

16.2

29.5

7.1

0.35
4.2 L = 2 m

36.8

6
7

Dimensions - XUM 2BppNL2R


16.2

29.5

7.1

Description - XUM 2BKCNL2T

(1)

R: Reception, T: Transmission.

0.35

Thru-beam system

40.8

4.2

(1) Output state LED.


(2) Stability and power on LED.

R: Reception

Photo-electric sensors

Dimensions

OsiSense XU Application, packaging and


machine tool series
Miniature design, metal
Three-wire DC, solid-state output

Accessories
Reflectors

Fixing bracket

XUZ C08

XUZC50
8.6

35

21

12.8

60

47

69

51

optical
Axis

20
44

(1)

5.5

16

33.3

29.5

3.3

25

10

2xM3

11

32

4xR5

23.3

3.2

XUZAM81

51.5

4.2

12

32

(1) 2 x M3

Optical axis
2x4.5

2x5.5

8.1

(1)

11
18

3.5

4.2

5.5

(1) Elongated holes 4.5 x 8

5
6
7
8
9
10

5/99

Photo-electric sensors

References,
characteristics,
accessories

OsiSense XU Application, assembly series


Miniature design
with laser transmission and teach mode
Three-wire DC, solid-state output

Miniature design

1
2
3

Laser
class 2
Laser class 2, conforming to IEC
825-1.
Visible laser radiation: do not stare
into beam.

System

Polarised reflex

Type of transmission

Red laser, pulsed, Class 2, wavelength: 655 nm

Nominal sensing distance (Sn)

1001000 mm (1)

2060 mm

30110 mm

40150 mm

XUY BCO929LSP

XUY PSCO929L1SP

XUY PSCO929L2SP

XUY PCCO929LSP

0.056

0.056

0.056

0.056

References

4-wire, PNP output

NO/NC function, selectable

Weight (kg)

Ambient air temperature

e
For operation

7
8

- 20+ 60 C

For storage

- 20+ 80 C

Conforming to IEC60529

IP67

Vibration resistance

Conforming to IEC60068-2-6

7 gn, amplitude 1.5 mm (f = 10 to 55 Hz)

Shock resistance

Conforming to IEC60068-2-27 30 gn, duration 11 ms

Materials

Case

Connection

Colour mark reader

Characteristics

Product certifications

Degree of protection

Diffuse with background suppression

M8, 4-pin male connector

ABS

Rated supply voltage

c 1224 V with protection against reverse polarity

Voltage limits (including ripple)

c 1030 V

Immunity to ambient light

5000 lux

Laser transmission

T pulse: 3 s, pulse frequency: 5 kHz

Spot diameter

< 0.7 mm

Switching capacity

100 mA with overload and short-circuit protection

Voltage drop, closed state

< 2.4 V

Current consumption, no-load

25 mA

Maximum switching frequency

1000 Hz

Indicator lights

Supply on/Dirty

Green LED

Output signal

Yellow LED

Adjustment

< 0.3 40 mm

< 0.7 mm

30 mA

25 mA

Using teach mode button or remote teaching (external input)

(1) With 50 x 50 mm reflector, reference XUY 1111.


b Applications
v Monitoring of small parts on production machines
v Setting-up of sensors

Accessories

Description

Details

Pre-wired M8
connector

Straight

Length
of cable

References

Reflector for
XUY BCO929LSP

10

XUY1111

5/100

kg
XZC P0941L2

0.080

Elbowed (90)

XZC P1041L2

0.080

Straight

XZC P0941L5

0.180

Elbowed (90)

XZC P1041L5

0.180

50 x 50 mm

XUY1111

0.018

Fixing bracket
Protection bracket

Weight

XUY929

0.013

Vertical rear fixing

XUY9291

0.070

Lower side fixing

XUY9292

0.061

Photo-electric sensors

Description,
schemes,
dimensions
Description

OsiSense XU Application, assembly series


Miniature design
with laser transmission and teach mode
Three-wire DC, solid-state output

XUY BCO929LSP
1
2
3

1
2
3

Teach In (T.I.)
Yellow LED: Detection LED (1)
Green LED: Supply on or fault
due to accumulation of dirt
(if LED off)

b Teach mode (yellow and green LEDs are on)


v Line up with reflector, press T.I. for 3 seconds: both LEDs flash
v Insert the object, press T.I. for 1 second: the green LED flashes then remains on (teaching
completed).

XUY PSCO929LpSP, XUY PCCO929LSP


1
2
3

Teach In (T.I.)
Yellow LED: Detection LED
(2)
Green LED: Supply on or fault
due to accumulation of dirt
(if LED off)

b Teach mode (yellow and green LEDs are on)


v Line-up with object, press T.I. for 3 seconds: both LEDs flash
v Insert the object, press T.I. for 1 second: the green LED flashes then remains on (teaching
completed)

R: Receiver
T: Transmitter

NO/NC b Press T.I. for 13 seconds: the two LEDs alternatively flash (on the release of T.I., the green LED remains on).

b Each press on T.I. changes the output state (NO, NC, NO, NC, ...). When T.I. is not pressed for 10 seconds, the green LED

1
2
3

(1) Whether the output is direct or inverse, the detection LED goes off only on beam break.
(2) Whether the output is direct or inverse, the detection LED comes on only when an object is present.

Dimensions

Wiring schemes

XUY BCO929LSP, XUY PSCO929LpSP


(1)

20

Pre-cabled

12

PNP

BN

17 (3)

9 (2)

24

2
1

(2)
(1)

1 BN: Brown
3

2 WH: White
3 BU: Blue
4 BK: Black

0V

32

BU

Pin n - colour

c 10-30 V

BK
WH

M8 connector

(1) - Connected to +: external teaching,


- Connected to : locking of functions
(2) Output 100 mA max.

2,6

10,7

M8x1

(1) 2 elongated holes 3.2 x 4.2.


(2) Transmitter optical axis.
(3) Receiver optical axis.

Application examples

Detection of pharmaceutical ampoules

7
Detection of connection tags on integrated circuits passing on rail

8
9
10

5/101

Photo-electric sensors

References,
dimensions

OsiSense XU Application, material handling


series
Laser transmission. Design 18, plastic or metal
Three-wire DC. Solid-state output
18, plastic, thru-beam system with teach mode,
laser transmission (Transmitter + receiver)

Sensing
Function
distance (Sn)
m
NO or NC, by
programming

0...100

Sensing
Function
distance (Sn)
m
NO or NC, by
programming

0...100

Connection
Pre-cabled
M12 connector

Weight
kg

PNP

XUB LAPCNL2

0.180

NPN

XUB LANCNL2

0.180

PNP

XUB LAPCNM12

0.078

NPN

XUB LANCNM12

0.078

Output Reference

Weight
kg

PNP

XUB LBPCNL2

0.230

NPN

XUB LBNCNL2

0.230

PNP

XUB LBPCNM12

0.130

NPN

XUB LBNCNM12

0.130

Separate components

18 transmitter
Description Connection
Plastic
Metal

XUB LppCNM12T

Output For use with

Reference

Pre-cabled

XUB LApCNL2

XUB LAKCNL2T

0.090

M12 connector

XUB LApCNM12

XUB LAKCNM12T

0.040

Pre-cabled

XUB LBpCNL2

XUB LBKCNL2T

0.110

M12 connector

XUB LBpCNM12

XUB LBKCNM12T

0.060

Weight
kg

18 receiver
Description Connection
Plastic

Pre-cabled
M12 connector

XUB LppCNL2R

Metal

Pre-cabled
M12 connector

Output For use with

Reference

Weight
kg

PNP

XUB LAPCNL2

XUB LAPCNL2R

0.090

NPN

XUB LANCNL2

XUB LANCNL2R

0.090

PNP

XUB LAPCNM12

XUB LAPCNM12R

0.040

NPN

XUB LANCNM12

XUB LANCNM12R

0.040

PNP

XUB LBPCNL2

XUB LBPCNL2R

0.120

NPN

XUB LBNCNM12

XUB LBNCNL2R

0.120

PNP

XUB LBPCNM12

XUB LBPCNM12R

0.070

NPN

XUB LBNCNM12

XUB LBNCNM12R

0.070

Fixing accessories for XUB Lp (1)


Description
XUZA218

Output Reference

18, metal, thru-beam system with teach mode,


laser transmission (Transmitter + receiver)

XUB LppCNM12

Pre-cabled
M12 connector

XUB LppCNL2

Connection

XUZ A318

Reference

Weight
kg

Precision fixing bracket with micrometric adjustment

XUZ A318

0.170

Plastic fixing bracket with adjustable ball-joint

XUZA218

0.035

(1) For further information, see page 5/158

Dimensions

b
a

(1) Yellow, green and red LED on receiver


(2) Green LED on transmitter
Note: fixing nut tightening torque: < 4 Nm

10

5/102

Pre-cabled
(mm)

Connector
(mm)

Receiver (1)

62

44

76

44

Transmitter (2)

52

28

66

28

Photo-electric sensors

Characteristics,
schemes,
curves

OsiSense XU Application, material handling


series
Laser transmission. Design 18, plastic or metal
Three-wire DC. Solid-state output

Characteristics
Sensor type

Product certifications
Connection

XUB LppppM12

XUB LppppL2

Pre-cabled
Nominal sensing distance Sn
Blind zone
Preferred object approach direction
Type of transmission
Transmission power
Degree of protection
Conforming to IEC60529
Temperature
Storage
Operation
Materials
Case
Lens
Vibration resistance
Conforming to IEC60068-2-6
Shock resistance
Conforming to IEC60068-2-27
Indicator lights
Output state and alignment aid
Supply on and teaching
Stability
Rated supply voltage

UL, CSA, e
M12 (suitable female connectors, including

pre-wired versions, see page 9/44)

Length: 2 m
0...100, excess gain 70...3
0
Any
Red laser, wavelength 670 nm
Power < 1 mW, class 1 conforming to IEC 825-1
IP 67, double insulation i
- 40... + 70
- 10... + 45
XUB LAppppp: PBT; XUB LBppppp: nickel plated brass
PMMA
7 gn, amplitude 1.5 mm (f = 10 to 55 Hz)
30 gn, duration 11 ms
Yellow LED
Green LED
Red LED
c 12...24 with protection against reverse polarity

Voltage limits (including ripple)


Current consumption, no-load
Switching capacity per output
Voltage drop, closed state
Maximum switching frequency
Delays
First-up
Response and recovery

V
mA
mA
V
Hz
ms
ms

c 10...30
25 for transmitter or receiver
y 100 with overload and short-circuit protection
y 1.5
1500
< 80
< 0.4

Wiring schemes

M12 connector
4

3 (-)
1 (+)
4 OUT/Output
2 Beam break
input

Connector

Pre-cabled

C
C

PNP

(-) BU (Blue)
(+) BN (Brown)
OUT/Output BK (Black)
Beam break input
VI (Violet)

BN/1
PNP

NPN

BN/1
NPN

BK/4

BU/3

1
2
3
4
5

Transmitter

1/BN
2/VI
3/BU

BK/4

BU/3

See connection on page 9/44

Curves

Input 2/VI:
- not connected: beam made
- connected to -: beam broken

Operating precautions

Detection curve (set to infinity)

Gain

Excess gain curve

10
m
-10

80
60
40
30
20

Laser
class 1

10
6
4
3
2

Laser class 1, conforming


to IEC 825-1.

1
0,1 0,2 0,4 1
0,3 0,6

10 20 40 100
30 60
D (m)

Adjustment

Detection limit curve

8
4
2
1
0,4
0,2
0,1

0,04
0,02
0,01
0,1 0,2 0,4
1
0,3 0,6

10 20 40 100
30 60
D (m)
Focusing point

Minimum size of the object to be


detected (mm)

Minimum size of the object to be


detected (mm)

Standard curve

8
4
2
1

0,4
0,2
0,1

0,04
0,02
0,01
0,1 0,2 0,4
1
0,3 0,6

10 20 40 100
30 60
D (m)
Focusing point

The adjustment of the focusing point enables the detection of objects down to a size of < 0.2 mm.
After slackening the fixing screws 1. adjust the focusing point of the laser beam by rotating the serrated sleeve 2 located on the face of the
sensor. Re-tighten fixing screws.
Note: fixing clamp XUZ A218 with ball-joint and, in particular, bracket XUZ A318 with precise micrometric adjustment and locking by 6 screws, are specially suited
for mounting the sensor and adjusting beam alignment when the sensing range is several tens of metres (see page 5/158).

5/103

10

Photo-electric sensors

References,
characteristics

OsiSense XU Application, material handling


series

With analogue output signal 420 mA and 010 V (1)


DC supply. Solid-state output

Compact design

2
3

System
Type of transmission
Nominal sensing distance (Sn)

Diffuse
Infrared
2080 cm

References

3-wire

PNP

XUJK803538

Weight (kg)

0.200

Product certifications

e, CSA, UL

Characteristics

4
5
6

Ambient air temperature


Vibration resistance

For operation
For storage
Conforming to IEC60068-2-6

Shock resistance

Conforming to IEC60068-2-27 20 gn, duration 11 ms

Degree of protection

Conforming to IEC60529
Conforming to NFC20-010

Connection

IP67
IP671
Screw terminals, maximum capacity: 2 x 1.5 mm2 or 1 x 2.5 mm2

Materials

Case: PEI (2)

Rated supply voltage

c 24 V with protection against reverse polarity

Voltage limits (including ripple)

c 2030 V

Output current

Maximum
Minimum

Output voltage (Vs)

7
8

- 25+ 60 C
- 40+ 80 C
7 gn, amplitude 1.5 mm (f = 1055 Hz)

20 mA
4 mA
c 010 V

Output voltage drift


in relation to temperature
Output voltage drift
in relation to object colour
Current consumption, no-load

< 10% between - 25 and + 60 C

Maximum switching frequency

10 Hz (for an output voltage variation of 1 V)

Delays
Indicator light

< 10%
y 35 mA

First-up

y 150 ms
The brightness of the LED is proportional to the output voltage
(1) Applications: position control, monitoring concentricity or eccentricity, closed loop regulation,
monitoring displacement, etc.
(2) PEI: high quality synthetic resin providing excellent withstand to mechanical shocks, vibration
and the effects of external agents frequently encountered in industry: alcohol, salts,
petroleum, oils, greases, washing agents (diluted sodium carbonate 4%, nitric acid 2%),
formaldehyde vapour, splashing lactic acid, etc.

9
10

5/104

Photo-electric sensors

Curves,
dimensions,
schemes,
connections

OsiSense XU Application, material handling


series

With analogue output signal 420 mA and 010 V (1)


DC supply. Solid-state output

Curves

Output signal (related to distance of object). Test performed with 20 x 20 cm, white 90% object
Output current

Output voltage

mA
20

V
10

10 %
10 %

4
0
2

15 20

40

80 D (cm)

60

15 20

40

60

80

D (cm)

Forbidden zone

Dimensions
XUJK803538
2,6

17

(3)
10

62,5
30 (4)

30,5

30

(2)

85

13

27,2

10

98,85

(1)

1,35

61

1010

10 20 9

32,6

83,6
(1) LED.
(2) 11P cable gland.
(3) 1 elongated hole 4.2 x 14.
(4) Front fixing ( 4 screws and inserts included).

Wiring schemes

Diffuse system
Current output

Voltage output

+
4
Vs

mA
1

Load characteristics
b Output current: the output current varies between 4 and 20 mA depending on the distance of the object and therefore, the load must be less than 1 k.
b Voltage output: since the minimum rated output current of the sensor is 10 mA, the load must always have a resistive value of more than 1 k

Terminal connections
1
2
3
4
5
6

()
(+)

Output voltage
Output current
( )

10

Terminals 1 and 6 connected internally.

5/105

References,
characteristics

Photo-electric sensors

OsiSense XU Application, material handling


series
With analogue output signal 420 mA (1)
DC supply

Design 18

2
3
4
5

System

Diffuse

Type of transmission

Infrared

Nominal sensing distance (Sn)

540 cm

References
3-wire, PNP

XU5M18AB20D

Weight (kg)

0.075

Characteristics
Product certifications

e, CSA, UL

Ambient air temperature


Vibration resistance

Conforming to IEC60068-2-6

For operation: - 25+ 55 C.


For storage: - 40+ 70 C
25 gn, amplitude 2 mm (f = 1055 Hz)

Shock resistance

Conforming to IEC60068-2-27

30 gn, duration 11 ms

Degree of protection

Conforming to IEC60529

IP67

Connection

Materials

M12 male connector, 4-pin


(suitable female connectors, including pre-wired versions, see page 9/44)
Case: nickel plated brass, lens: PMAA

Rated supply voltage

c 1224 V with protection against reverse polarity

Voltage limits

c 1030 V (including ripple)

Output current

7
8
9

Maximum

20 mA

Minimum

4 mA

Output current drift in relation to temperature

< 10% between - 25 and + 55 C, < 5% between 0 and + 40 C

Output current drift in relation to supply

< 3%

Current consumption, no-load

y 30 mA

Maximum switching frequency

20 Hz (for an output current variation of 10 mA)

Delays

First-up: y 50 ms

Indicator light

The brightness of the green LED is proportional to the output current


Ie = 20 mA: indicator light at maximum intensity
Ie = 4 mA: indicator light at minimum intensity

(1) Applications: position control, monitoring concentricity or eccentricity, closed loop regulation, monitoring displacement, etc.

10

5/106

Photo-electric sensors

Curves,
dimensions,
schemes

OsiSense XU Application, material handling


series

With analogue output signal 420 mA


DC supply

Output signal (related to distance of object)


Potentiometer set at maximum
Is (mA)
25

Is (mA)
25

20

20

15

15

2
2

Potentiometer set at minimum

10

10

5
4

5
4

1
0

10

20

30

40

1 White 90% object


2 Grey 15% object

50
D (cm)

10

20

30

40

50
D (cm)

1 White 90% object


2 Grey 15% object

Dimensions
4

M18x1 (1) (2)

24

55
82
95
(1) Potentiometer.
(2) Green LED.
Fixing nut tightening torque: 15 N.m.
Connector tightening torque: 2 N.m.

Wiring schemes

Connector scheme

Diffuse system
Output current

Sensor connector pin view

1
2
R
D

Ie = 420 mA

4
3 ( )

mA
3

1 (+)
Analogue 2
output

See connection on page 9/44.

Load characteristics (R)


The output current varies between 4 and 20 mA, depending on the distance of the object, and therefore, the load must be less than 800 for a 24V supply and less
than 300 for a 12V supply.

8
9
10

5/107

Photo-electric sensors

References,
characteristics

OsiSense XU Application, material handling


series
Through beam system with high excess gain (1)
Solid-state output and analogue output 420 mA

Design 18

1
2
3

System

Thru-beam

Type of transmission

Infrared

Nominal sensing distance (Sn) / maximum

50 m / 70 m (transmitter + receiver)

3-wire, PNP

XU2M18AP20D (2)

References

Weight (kg)

Vibration resistance
Shock resistance
Degree of protection
Connection
Materials

0.155

Characteristics

Product certifications
Ambient air temperature

NO (object detection) +
analogue output

Rated supply voltage


Voltage limits
Solid-state digital output

7
Analogue output

For operation
For storage

Conforming to IEC60068-2-6
25 gn, amplitude 2 mm (f = 1055 Hz)
Conforming to IEC60068-2-27 30 gn, duration 11 ms
Conforming to IEC60529
IP67
M12 male connector, 4-pin (suitable female connectors, including pre-wired versions, see
page9/44)
Case
Nickel plated brass
Lenses
PMMA

Switching capacity (sealed)

c 1224 V with protection against reverse polarity


c 1030 V (including ripple)
100 mA with overload and short-circuit protection

Voltage drop, closed state


Maximum switching frequency

1.5 V
30 Hz

First-up delay
Response delay
Recovery delay

50 ms
15 ms
15 ms

Output current

420 mA
Drift < 5% for temperature between 0 and + 40 C
15 ms

Delay

Current consumption, no-load


Indicator lights
Transmitter
Receiver

e, CSA, UL
- 25+ 55 C
- 40+ 70 C

55 mA (transmitter + receiver)
Green LED, supply on
Yellow LED illuminated = beam transmission
Yellow LED illuminated = solid-state output ON = object detected within beam
Green LED: the brightness of the LED is proportional to the output current:
- for l = 20 mA, object slightly opaque, intensity at maximum,
- for I = 4 mA, object completely opaque, intensity at minimum.
(1) Applications: detection of objects in spite of a difficult environment (smoke, dust, mist, etc.),
detection of objects inside packaging, etc.
Example of values
Object: white sheets of 80 gsm paper. Transmitter-receiver distance = 10 cm
Number of sheets
1
11
27
31
Analogue output current (mA)
17.3
12
6
5
(2) Reference for both transmitter and receiver for thru-beam system.
(3) Accessories, see page 5/158.

10

5/108

Photo-electric sensors

Dimensions,
curves,
schemes,
operation

Through beam system with high excess gain


Solid-state output and analogue output 420 mA

Dimensions

Curves

OsiSense XU Application, material handling


series

Detection curve

(2)

M18x1

Thru-beam system

(1)

of beam
cm

55

24

82

95
(1) LEDs
(2) Potentiometer (only on receiver)
Fixing nut tightening torque: 15 N.m
Connector tightening torque: 2 N.m

Excess gain curve (ambient temperature: + 25 C)


Thru-beam system
5

Wiring schemes

3
2

Receiver

1
2 Ie = 420 mA
mA
4

3
2

Ie = 0100 mA
R

104
8
5

103
800
500

Beam break test (only on transmitter)


Beam broken

300
200

1
2

30
20

Connector scheme

10
8
5

Sensor connector pin view

Transmitter

Receiver

1 (+)

Test 2

4
3 ()

100
80
50

3
2

R max. < 800 (Ue = 24 V), < 300 (Ue = 12 V)

Beam made

105
8
5

1 (+)

Analogue 2
output

4
3 ()

3
2

Solid-state
output

1
0,1

0,2 0,3 0,5

10

20 30

50

100
D (m)

See connection on page 9/44

Operation, settings
Type, opacity of object

Analogue output curve

Switching level of digital solid-state


PNP output
Potentiometer
set at minimum

Degree of opacity of object

Potentiometer
set at maximum

Output current

mA
25
20
18

15
10
5
4
0

0,1

99,4

99,5

99,6

99,7

%
99,8
99,9 99,95 100
Degree of opacity of object

10

Accessories:
page 5/158

5/109

Photo-electric sensors

References,
characteristics,
accessories

OsiSense XU Application, material handling


series
With analogue output signal 0...10 V or 420 mA
Laser transmission

Compact design, 50 x 50

1
Laser
class 2
Laser class 2, conforming to
IEC825-1

Visible laser radiation: do not stare


into beam.

System

Diffuse

Type of transmission

Red laser, pulsed, Class 2, wavelength: 670 nm

Measuring distance

4060 mm

4585 mm

80300 mm

3-wire, PNP output

XUY PCO925L1ANSP

XUY PCO925L2ANSP

XUY PCO925L3ANSP

Weight (kg)

0.057

0.057

0.057

20 m

200 m

References

Characteristics

Product certifications

Ambient air temperature

5
6
7
8

Degree of protection

e
For operation

0+ 45 C

For storage

- 20+ 60 C

Conforming to IEC60529

IP67

Resolution

7 m

Linearity

< 1%

Temperature stability

10 m/K

Connection

M12 male connector with alternative orientations

Vibration resistance

Conforming to IEC60068-2-6

Shock resistance

Conforming to IEC60068-2-27 30 gn, duration 11 ms

Materials

Case

< 0.25%
18 m/K

22 m/K

7 gn, amplitude 1.5 mm (f = 10 to 55 Hz)


ABS, anti-shock

Rated supply voltage

c 24 V with protection against reverse polarity

Voltage limits (including ripple)

c 1828 V

Immunity to ambient light

5000 lux

Output signal

010 V

420 mA

Output activation time


(from 10 90%)

30 ms

0.4 ms (fast speed mode)


40 ms (medium speed mode)

Laser transmission

T pulse: 8 s, pulse frequency: 6 kHz, time base: 250 ms

Spot diameter

< 1 mm
at 50 mm

Switching capacity

3 mA with overload and short-circuit protection

Voltage drop, closed state

< 2.4 V

Current consumption, no-load

35 mA

Maximum switching frequency

40 Hz

Indicator lights
Parametering

Dirty

Red LED

Supply on

Green LED

< 0.8 mm
at 65 mm

1.5 x 3.5 mm
at 80 mm

y 40 mA on c 24 V

By buttons

b Applications: position control of robot arm, measuring thickness of mechanical parts.

Accessories

Description

Details

Length of cable

References

m
Pre-wired M12
connector

Straight,
4-pin
Straight,
5-pin

10

XZC P1141L2

0.090

XZC P1141L5

0.190

XZC P1164L2

0.115

XZC P1164L2

0.270

XUY925

0.033

Fixing bracket
Protection bracket

5/110

Weight
kg

Vertical rear fixing

XUY9251

Photo-electric sensors

Presentation,
dimensions,
schemes,
curves

OsiSense XU Application, material handling


series

With analogue output signal 0...10 V or 420 mA


Laser transmission

Presentation

XUY PCO925L1ANSP, XUY PCO925L2ANSP


1-2

1
2

XUY PCO925L3ANSP
1-2

Green/red LED
LED display

Application example
1
2

Monitoring dimensions in series

Green/red LED
Parametering by
buttons

R: Receiver
T: Transmitter

Dimensions

17

39,5 (3)

30

(1)

18 (2)
31,8 (3)

50

16

30

50

18 (2)

17

(1)

16

50

XUY PCO925L3ANSP

50

XUY PCO925L1ANSP, XUY PCO925L2ANSP

38

38

M12x1

M12x1

(1) 2 elongated holes 4.3 x 4.


(2) Transmitter optical axis.
(3) Receiver optical axis.

Wiring schemes

XUY PCO925L1ANSP, XUY PCO925L2ANSP

XUY PCO925L3ANSP

Connector
M12
PNP

BN

18-28 V

WH

BK
BU

0V

Connector
Pin n - colour

1 BN: Brown

2 WH: White

M12
PNP

3 BU: Blue

4 BK: Black

Shielding

18-28 V

WH/BK

QA

BU

0V

BK

BN

YW/GR

Pin n - colour
3

1 BN: Brown

2 WH: White
3 BU: Blue
4 BK: Black
5 GY: Grey

IN

QA: 4-20 mA analogue output (R y 500 W)


Q: Switching output
IN: Control input (YW/GR: Yellow/green)

Note: Shielded cable recommended.

Adjustment curves

XUY PCO925L1ANSP, XUY PCO925L2ANSP


V
10

XUY PCO925L3ANSP
mA
20

10

20

40 45

60

80 85 mm

10
80

300

mm

1 XUY PCO925L1ANSP
2 XUY PCO925L2ANSP

5/111

Photo-electric sensors

References,
characteristics,
accessories

OsiSense XU Application, material handling series


Diffuse, with laser transmission
With background suppression
DC supply. Solid-state output

Compact design

Laser
class 2
Laser class 2, conforming to IEC825-1

Visible laser radiation: do not stare


into beam.

System

Red laser, pulsed, Class 2, wavelength: 675 nm

Detection distance

Adjustable from 50 to 300 mm

Minimum size of object

0.5 mm

References

4-wire, PNP and NPN output

Diffuse with background suppression

Type of transmission

NO/NC
depending on wiring

Weight (kg)

0.081

Characteristics

Product certifications

Ambient air temperature

5
6
7
8

Degree of protection

e, cULus (1)
For operation

0+ 50 C

For storage

- 20+ 80 C

Conforming to IEC60529

IP65

Connection
Materials

XUY PS1LCO965S

M8, 4-pin male connector (for pre-cabled version please consult our Customer Care Centre)
Case

Glass impregnated nylon

Lens

PMMA

Rated supply voltage

c 1224 V with protection against reverse polarity

Voltage limits (including ripple)

c 1030 V

Immunity to ambient light


Laser transmission

Incandescent bulb

500 lux

Natural light

10 000 lux

Pulsed laser LED

T pulse: 6 s, T period < 50 s

Spot size

Manual adjustment of focusing

Switching capacity

100 mA with overload and short-circuit protection

Voltage drop, closed state

<2V

Current consumption, no-load

35 mA

Maximum switching frequency

5 kHz

Delays

Response and recovery

< 150 s

Indicator lights

Time delay active

Red indicator

Output state

Green indicator

NO function

Red indicator

NC function

Indicator off

Output signal time delay

40 ms, depending on wiring

(1) This product is UL Listed if supplied by a class II or isolated supply delivering c 30 V max. (isolated transformer for example) and protected by a UL fuse rated
at 3 A max.
Applications: monitoring of small parts on production machine, detection of components on a printed circuit, monitoring for crack on a component, control of level,
suppression of a background.

Accessories

Description

Details

Pre-wired M8
connector

Straight

Length
of cable

References

10

5/112

Weight
kg

XZC P0941L2

0.080

Elbowed (90)

XZC P1041L2

0.080

Straight

XZC P0941L5

0.180

Elbowed (90)

XZC P1041L5

0.180

Photo-electric sensors

Presentation,
dimensions,
schemes

OsiSense XU Application, material handling series

Diffuse, with laser transmission


With background suppression
DC supply. Solid-state output

Presentation

XUY PS1LCO965S
Rear view

6
5

1
2
3
4
Timer

5
6

Output

Adjustment of spot size


Detection distance adjustment screw
M8 connector
On: NO function
Off: NC function
Object detected
Time delay active

LO/DO

Dimensions
5

Wiring schemes

NO function
60

18

Without time delay


BN
BU
BK
WH

60

54

(1)

Output

BN
BU
BK
WH

9
2x4,1

(1) Optical axis of laser

BN
BU
BK
WH

Output

NC function
Without time delay

23

With 40 ms time delay

With 40 ms time delay

+
Output

BN
BU
BK
WH

+
Output

M8 connector
2
1

Pin n - colour

1 BN: Brown
3

2 WH: White
3 BU: Blue

4 BK: Black

Application examples

Monitoring for crack in a component

Monitoring for a broken punch on press tool

8
9
10

5/113

Photo-electric sensors

References,
characteristics,
accessories

OsiSense XU Application, material handling series


Diffuse, with 2 channels using triangulation
with background suppression
DC supply. Solid-state output

Compact design

1
2
3
4

System

Diffuse with background suppression

Type of transmission

Infrared LED, modulated, 15 mm beam

Detection distance

Adjustable from 50 to 600 mm

References

4-wire, PNP and NPN output

NO/NC programmable
function

Weight (kg)

Characteristics

Product certifications

Ambient air temperature

Degree of protection

0.135

0.055

0+ 50 C

For storage

- 20+ 80 C

Conforming to IEC60529

IP65
Pre-cabled, length 2 m

Case

M8, 4-pin male connector

Glass impregnated nylon

Rated supply voltage

c 1224 V with protection against reverse polarity

Voltage limits
(including ripple)

c 1030 V

Immunity to ambient light

Incandescent bulb

1300 lux

Natural light

10 000 lux

Switching capacity

100 mA with overload and short-circuit protection

Voltage drop, closed state

<2V

Current consumption, no-load

< 1.5 W

Maximum switching frequency

XUY PS2CO945S

e, cULus (1)
For operation

Connection
Materials

XUY PS2945S

370 Hz

Delay

Response and recovery

< 1.8 ms

Output signal time delay

For A and B/A or B (2)

Determined by wiring

Indicator light

Output signal

Green LED

(1) This product is UL Listed if supplied by a class II or isolated supply delivering c 30 V max. (isolated transformer for example) and protected by a UL fuse rated
at 3 A max.
(2) See next page

b Applications:
v Control of filling, detection of object on conveyor against reflective background.

Accessories

Description

Details

Pre-wired M8
connector

Straight

Length
of cable

References

9
10

5/114

Weight
kg

XZC P0941L2

0.080

Elbowed (90)

XZC P1041L2

0.080

Straight

XZC P0941L5

0.180

Elbowed (90)

XZC P1041L5

0.180

Photo-electric sensors

Presentation, description,
dimensions,
curves,
schemes

OsiSense XU Application, material handling series


Diffuse, with 2 channels using triangulation
with background suppression
DC supply. Solid-state output

Presentation

Description (4 operating modes)

XUY PS2945S, XUY PS2CO945S


Rear view

9
8

1 Adjustment of zone A detection


distance
2 Adjustment of zone B detection
distance
3 Pre-cabled connection
(XUYPS2945S)
or M8 connector
1
4 (XUYPS2CO945S)
5 On in direct mode
Illuminates when the exclusive
2
OR function between the two
6 zones A and B is obtained
On when the object is present
7 in zone B
On when the object is present
8 in zone A
Illuminates when the AND
object logic function between
9 the two zones A and B is
5 & 8 obtained
Indicates time delay mode
Simultaneously on when the
OR logic function between
the 2 zones A or B is obtained

Timer
A and B

7
6

A
B

5
4

A xor B
LO/DO

Dimensions

Immunity to reflection: A and B

Mirror

Detected zones

Detected zone

Detection of contrasting objects:


A or B

Monitoring of distance: A xor B

Detected zone

Detected zone

3
4

Detection curves (typical)

XUY PS2945S, XUY PS2CO945S


60

Two independent sensors with


triangulation: A, B

XUY PS2945S, XUY PS2CO945S


18

100

60

54

(1)

23

2x4,1

10

1
50

6
100

200

300

400

500

600
mm

1 Black 6%
2 Grey 18% - Distance (mm) set on 92% (Kodak 1527795)
(1) Optical axis.

Wiring schemes and outputs

Two independent sensors with triangulation: A, B


NO output
BR
BU
BK
WH

NC output
+ 10/30 V
0V
Zone A output
Zone B

BR
BU
BK
WH

NO output
0V
+10/30 V
Zone A output
Zone B

Detection of contrasting objects: A or B


NO output
BR
BU
BK
WH

NC output
+ 10/30 V
0V
Output

BR
BU
BK
WH

Immunity to reflection: A and B


Without time delay
BR
BU
BK
WH

+10/30 V
0V
Output

BR
BU
BK
WH

NO output
0V
+10/30 V
Output

Monitoring of distance: A xor B


Without time delay
NO output

0V
+ 10/30 V
Output

With 40 ms time delay

NC output

BR
BU
BK
WH

BR
BU
BK
WH

BR
BU
BK
WH

+10/30 V
0V
Output

0V
+10/30 V

NO output
0V
+10/30 V
Output

BR
BU
BK
WH

NC output
+10/30 V
0V
Output

BR
BU
BK
WH

Output

With 40 ms time delay

NC output
+10/30 V
0V
Output

BR
BU
BK
WH

NC output

0V
+10/30 V

Output

10

BR: Brown
BU: Blue
BK: Black
WH: White

5/115

References

Photo-electric sensors

OsiSense XU Application

Fibre design, amplifiers


Three-wire DC, solid-state output
Teach mode

561584

Amplifiers with fine adjustment and 4-digit screen

Sensing
Function
Output
distance (Sn)
m
Depending on NO/NC
PNP
fibre
Programmable

NPN

Reference

Weight
kg

Pre-cabled

XUDA2PSML2

0.040

M8
connector
Pre-cabled

XUDA2PSMM8

0.040

XUDA2NSML2

0.040

M8
connector

XUDA2NSMM8

0.040

Connection

Reference

Pre-cabled

XUDA1PSML2

0.040

M8
connector
Pre-cabled

XUDA1PSMM8

0.040

XUDA1NSML2

0.040

M8
connector

XUDA1NSMM8

0.040

XUDA2

Amplifiers using teach mode


Sensing
Function
distance (Sn)
m

Output

Depending on NO/NC
PNP
fibre
Programmable

561785

Connection

NPN

5
XUDA1

6
7
8
9
10

5/116

Weight
kg

Photo-electric sensors

Characteristics,
schemes,
dimensions

OsiSense XU Application

Fibre design, amplifiers


Three-wire DC, solid-state output
Teach mode

Characteristics
Sensor type
Product certifications
Connection

Connector
Pre-cabled

Sensing distance (Sn)

Operating temperature
Vibration resistance
Shock resistance
Indicator lights

Length: 2 m

Conforming to IEC60529
C
C

Conforming to IEC60068-2-27
Output state
Stability
Stability

Signal level
Rated supply voltage

Voltage limits (including ripple)

c 10.826.4

Current consumption, no-load


Switching capacity
Alarm output
Protection against mutual interference

mA
mA
mA

y 50
y 100 with overload and short-circuit protection
y 50 for XUDA2 with overload and short-circuit protection
Yes for XUDA2

Voltage drop, closed state


Maximum switching frequency

V
kHz

y 2 for XUD ApPpppp, y 1 for XUD ApNppppp


1 kHz for XUD A1, 1 or 5 kHz configurable for XUDA2

Output time delay

ms

0 or 40 on recovery for XUDA2

ms
ms
ms

< 120
< 0.5 (0.1 for XUDA2 in fast frequency mode)
< 0.5 (0.1 for XUDA2 in fast frequency mode)

First-up
Response
Recovery

XUD A2 wiring schemes


M8 connector

Pre-cabled

1(+)
3 (-)
4 (OUT/output)
2 (alarm)

PNP

BN Brown (+)
BU Blue (-)
BK Black (output)
WH White (alarm)
(WH only on XUDA2)

XUD A1 wiring schemes


M8 connector

2
1

4
3

Pre-cabled

1(+)
3 (-)
4 (OUT/output)
2

4
5
6

NPN

BN/1
PNP

BK/4 WH/2

BU/3

PNP

BN Brown (+)
BU Blue (-)
BK Black (Output)

- 10+ 55
7 gn, amplitude 0.5 mm (f = 10 to 55 Hz)

Conforming to IEC60068-2-6

30 gn, duration 11 ms
Yellow LED
Red LED for XUDA1
Green LED for XUDA2
By 7 segment/4-digit display for XUDA2
c 1224 with protection against reverse polarity

Delays

Depending on fibre used,see page 5/118. Sensing distance halved for XUDA2
configured for fast frequency
Teach mode on XUDA1,
Teach mode and fine adjustment (+/- button) plus 4-digit screen on XUD A2
Red
IP 65 with 2 mm fibre (IP 64 with 1 mm fibre)
- 30+ 70

Sensitivity adjustment
Type of transmission
Degree of protection
Storage temperature

XUDA1ppSML2,
XUDA2ppSML2

XUDA1ppSMM8,
XUDA2ppSMM8
e, cULus
M8

BN/1
NPN

+
BK/4

WH/2

BU/3

NPN

BN/1
PNP

BK/4

BU/3

BN/1
NPN
BU/3

BK/4

See connection on page 9/44

Dimensions
XUDAp

XUDA1
ALM

OUT

40

SET

XUDA2
-

65

SET

OUT

1234

10

H T S

10

5/117

Photo-electric sensors

OsiSense XU Application
Fibre optics for amplifiers

PLASTIC fibres with end fittings, thru-beam system

Dimensions,
references,
characteristics,
curves

M4
x0,7

1,5

M4
x0,7

M2,6
x0,45
M3
x0,5

12 3

M2,6
x0,45

15 5 90

12 3

R = minimum bend radius


Fibre of ext. 2.2 mm, R = 25 mm
Fibre of ext. 1 mm, R = 10 mm
XUFN2S01Lp, R = 4 mm

3
2,2

2,2

Nominal sensing distance (Sn) With fibre L = 2 m


With lens
Application, features

200 mm (1)
1500 mm (2)
General purpose

180 mm

50 mm (1)
1000 mm (2)
Accurate positioning

XUFN12301
XUFN12301L10

0.058 (L = 2 m)

XUFN12311
0.030

XUFN35301

0.045

1x1
Yes

1x1
Yes

1 x 0.5
Yes

References (complete assembly - 2 fibres)


With standard
end fittings

L=2m
L = 10 m
With 90 mm flexible end fittings, L = 2 m
Weight (kg)

Characteristics
Fibre (view on sensing face)

6
7

Core ( mm)
Trimmable to required length
(trimmer XUFZ11 included)
Ambient air temperature
Vibration resistance
Shock resistance
Degree of protection
Materials

For operation: - 25+ 60 C. For storage: - 40+ 80 C


7 gn, amplitude 1.5 mm (f = 1055 Hz), conforming to IEC 60068-2-6
30 gn, duration 11 ms, conforming to IEC 60068-2-27
IP 64 conforming to IEC 60529 and IP 641 conforming to NF C 20-010
Fibres: PMMA; sheath: PE

Detection curves
XUFNpppppL10
Percentage reduction in sensing distance
related to length of fibre

XUFN12301, N12311

XUFN35301

100%
mm

50%
200

0%

100

2m

5m
10 m
Length of fibre
cm 6 3

10

of
beam

(1) Can be used with 90 mirror XUFZ02, see page 5/125.


(2) With lens accessory XUFZ01, see page 5/125.

5/118

Sn 200 mm

mm

-3 -6

25
cm 6 3
of
beam

-3 6

Photo-electric sensors

Dimensions,
references,
characteristics,
curves

OsiSense XU Application
Fibre optics for amplifiers

PLASTIC fibres with end fittings, thru-beam system

15

M3
x0,5

M4
x0,7

M8
x1,25

M2,6
x0,45
M4
x0,7

12 3

M2,6
x0,45

12 3

90

0,8

20

3
1

2,2

2,2

30 mm

Accurate positioning

300 mm (1)
2000 mm (2)
Long sensing distance fibres

2500 mm

Fibres with integral lens


Resistant to accumulation of dirt

100 mm (1)
750 mm (2)
Flexible fibres for cyclic movements,
areas with restricted access

XUFN35311
0.045

XUFN2P01L2
XUFN2P01L10

0.058 (L = 2 m)

XUFN2L01L2
XUFN2L01L10

0.060 (L = 2 m)

XUFN2S01L2
XUFN2S01L10

0.062 (L = 2 m)

1 x 0.5
Yes

1 x 1.5
Yes

1x1
Yes

1x1
Yes

5
6

For operation: - 25+ 60 C. For storage: - 40+ 80 C


7 gn, amplitude 1.5 mm (f = 1055 Hz), conforming to IEC 60068-2-6
30 gn, duration 11 ms, conforming to IEC 60068-2-27
IP 64 conforming to IEC 60529 and IP 641 conforming to NF C 20-010
Fibres: PMMA; sheath: PE

XUFN35311

XUFN2P01L2

7
XUFN2L01L2

XUFN2S01L2

mm

2500

mm

mm

2000

mm

300
200

700

100

15
cm 6 3
of
beam

-3 6

cm 6 3
of
beam

-3 -6

cm 9 6 3
of
beam

-3 -6 -9

cm 6 3

-3 -6

of
beam

10

5/119

Dimensions,
references,
characteristics,
curves

Photo-electric sensors

OsiSense XU Application
Fibre optics for amplifiers

PLASTIC fibres with end fittings, diffuse system

15

M6
x0,75

15

M6
x0,75

15

90

R = minimum bend radius


Fibre of ext. 2.2 mm, R = 25 mm
Fibre of ext. 1 mm, R = 10 mm
XUFN5S01Lp, R = 4 mm

M6
x0,75

2,2

Nominal sensing distance (Sn)


Application, features

70 mm
General purpose

60 mm

60 mm
Positioning

With standard
end fittings

L=2m
L = 10 m
With 90 mm flexible end fittings, L = 2 m

XUFN05321
XUFN05321L10

XUFN05331

XUFN05323

Weight (kg)

0.058 (L = 2 m)

0.030

0.060

2x1
Yes

2x1
Yes

1 x 1 + 16 x 0.265
Yes

References

Characteristics

Fibre (view on sensing face)

Core ( mm)
Trimmable to required length
(trimmer XUFZ11 included)

6
7

Ambient air temperature


Vibration resistance

For operation: - 25+ 60 C. For storage: - 40+ 80 C


7 gn, amplitude 1.5 mm (f = 1055 Hz), conforming to IEC 60068-2-27

Shock resistance
Degree of protection
Materials

30 gn, duration 11 ms, conforming to IEC 60068-2-27


IP 64 conforming to IEC 60529 and IP 641 conforming to NF C 20-010
Fibres: PMMA; sheath: PE

Detection curves (object 10 x 10 cm, white 90%)


XUFNpppppL10
Percentage reduction in sensing distance
related to length of fibre

XUFN05321

XUFN05331, XUFN05323
mm

mm

100%

70

50

50

20

20

50%

2m

5m

10 m

Length of fibre

(1) Fixing clamps included with fibre optic.

10

5/120

mm 9 6 3
of
beam

-3 -6 -9

mm 9 6 3
of
beam

-3 -6 -9

Photo-electric sensors

Dimensions,
references,
characteristics,
curves

OsiSense XU Application
Fibre optics for amplifiers

PLASTIC fibres with end fittings, diffuse system

15

13

3 12

12

M4
x0,7
M2,6
x0,45

15

M3
x0,5

15

90

M4
x0,7

3 12

1
3 12

M4
x0,7

18 mm
Positioning

18 mm
Positioning

6 mm
Areas with restricted
access

15 mm
Positioning

95 mm
Long sensing distance
fibres

55 mm
Flexible fibres for cyclic
movements, areas with
restricted access

XUFN01321

0.045

XUFN01331
0.045

XUFN04331

0.045

XUFN02323

0.040

XUFN5P01L2
XUFN5P01L10

0.058 (L = 2 m)

XUFN5S01L2
XUFN5S01L10

0.062 (L = 2 m)

3
4
5

2 x 0.5
Yes

2 x 0.5
Yes

2 x 0.265
Yes

1 x 0.5 + 4 x 0.25
Yes

2 x 1.5
Yes

2x1
Yes

For operation: - 25+ 60 C. For storage: - 40+ 80 C


7 gn, amplitude 1.5 mm (f = 1055 Hz),
7 gn, amplitude 1.5 mm (f = 1055 Hz), conforming to IEC 60068-2-6
conforming to IEC 60068-2-27
30 gn, duration 11 ms, conforming to IEC 60068-2-27
IP 64 conforming to IEC 60529 and IP 641 conforming to NF C 20-010
Fibres: PMMA; sheath: PE

XUFN01321, N01331

XUFN04331

XUFN02323

XUFN5P01L2

XUFN5S01L2

mm
90

mm

10
mm 6 3

of
beam

-3 -6

of
beam

mm 6 3

of
beam

-3 -6

20

20

7,5

-3 -6

50

50

15

3
mm 6 3

15

mm

mm

mm

70

mm 9 6 3

of
beam

-3 -6 -9

mm

63

-3 -6

of
beam

10

5/121

Photo-electric sensors

OsiSense XU Application
Fibre optics for amplifiers Full colour

PLASTIC fibres with end fittings, diffuse system

(3)
15 9,8

30,7

15 9,8

(3)

15

30

20

15 9,8

(1)

2000

2000

2000
29,7
10

14,5

(1)

(3)

(2)

(1)

11,6

(2)

11,6

4
6

(2)

R = minimum bend radius


R = 40 mm

30

34

9,2

30

30,7

Dimensions,
references,
characteristics

16
(1) Fibre reference ring for transmitter
(2) Transmitter
(3) 2 elongated holes 3.2 x 6.7 for M3 screws
Maximum tightening torque: 0.3 N.m
Nominal sensing distance (Sn)
with fibre L = 2 m
Application, features

10 mm

20 mm

30 mm

Focused fibres, specially suited to OsiSense XU Full colour sensors XURC4pPML2

References

With specific end fittings for


detection of colours
Weight (kg)

L=2m

XUFN5L01L2

XUFN5L02L2

XUFN5L03L2

0.030

0.030

0.030

Transmitter: 1 x 1
Receiver: 1 x 1.5
No

Transmitter: 1 x 1.5
Receiver: 1 x 1.5
No

Transmitter: 1 x 1.5
Receiver: 1 x 1.5
No

Characteristics
Fibre (view on sensing face)

7
8

Core ( mm)
Trimmable to required length
Spot diameter
Ambient air temperature
Vibration resistance
Shock resistance
Degree of protection
Materials

9
10

5/122

2.5 mm
5 mm
8 mm
For operation: - 10+ 55 C. For storage: - 20+ 70 C
7 gn, amplitude 1.5 mm (f = 1055 Hz), conforming to IEC 60068-2-6
30 gn, duration 11 ms, conforming to IEC 60068-2-27
IP 65 conforming to IEC 60529 and IP 651 conforming to NF C 20-010
Fibres: PMMA; sheath: PE. Head: PA 66, lens: PC

Dimensions,
references,
characteristics,
curves

Photo-electric sensors

OsiSense XU Application
Fibre optics for amplifiers

GLASS fibres with end fittings, thru-beam and diffuse


systems

32,5

M6

R = minimum bend radius


Metal sheath, R = 90 mm

970

M4

25

M2,6
M2,6
M4

970

3
4

System
Nominal sensing distance (Sn)
with fibre L = 1 m
Application

Thru-beam
200 mm (1)
1500 mm (2)
High temperatures

Diffuse
70 mm

References (complete assembly - 2 fibres for thru-beam system)


With standard end fittings
Weight (kg)

L=1m

XUFS2020
0.070

XUFS0520
0.075

Characteristics

Fibre (view on sensing face)

Core ( mm)
Ambient air temperature
Vibration resistance
Shock resistance
Degree of protection
Materials

1x1
2x1
For operation and storage: - 40+ 180 C
7 gn, amplitude 1.5 mm (f = 1055 Hz), conforming to IEC 60068-2-6
30 gn, duration 11 ms, conforming to IEC 60068-2-27
IP 64 conforming to IEC 60529 and IP 641 conforming to NF C 20-010
Fibres: glass; sheath: metal

Detection curves
XUFS2020

mm

XUFS0520

mm

200
70
50

100

9
cm 6 3

of
beam

-3 -6

cm 2 1

-1 -2

of
beam

10

(1) Can be used with 90 mirror XUFZ02, see page 5/125.


(2) With lens accessory XUFZ01, see page 5/125.

5/123

Photo-electric sensors

Dimensions,
references,
characteristics,
curves

OsiSense XU Application
Fibre optics for amplifiers

PLASTIC fibres without end fittings, thru-beam system

R = minimum bend radius


Fibre of ext. 2.2 mm, R = 25 mm

2
3
4

Nominal sensing distance (Sn) L = 2 m


Application

See detection curves below (1)


General purpose

Fibre without end fitting


Weight (kg)

XUFZ910
0.020

XUFZ920
0.040

XUFZ911
0.040

XUFZ921
0.080

1x1
10 m
Yes

20 m

1 x 1.4
10 m
Yes

20 m

References

Characteristics

Fibre
Core ( mm)
Length
Trimmable to required length
(trimmer XUFZ11 included)

Ambient air temperature


Vibration resistance
Shock resistance
Degree of protection
Materials

XUFZ911, Z921
XUFZ910, Z920

For operation: - 25+ 60 C. For storage: - 40+ 80 C


7 gn, amplitude 1.5 mm (f = 1055 Hz), conforming to IEC 60068-2-6
30 gn, duration 11 ms, conforming to IEC 60068-2-27
IP 64 conforming to IEC 60529 and IP 641 conforming to NF C 20-010
Fibres: PMMA; sheath: PE

Detection curves
XUFZ910, Z920

XUFZ911, Z921

Sensing distance (thru-beam system)

300 mm
250 mm

150 mm
120 mm
100 mm

200

300

50 mm
0 mm

mm

mm

200 mm

100
4 m 10 m

20 m

30 m

150

40 m

Length of fibre

1 XUFZ911, Z921
2 XUFZ910, Z920

Total length = sum of the 2 strands


used to constitute a thru-beam system

cm 6 3
of
beam

-3 -6

cm 8 4

-4 -8

of
beam

(1) It is possible to increase the sensing distance of fibres without end fittings by using fixing clamps with lens (XUFZ03, Z04 or Z05), see page 5/125.

10

5/124

Photo-electric sensors

References

OsiSense XU Application
Fibre optics for amplifiers

Accessories

Accessories for fibres with threaded end fittings


Description
XUFZ02

For use with

Reference

Weight
kg
0.005

1
2

90 mirror
(set of 2)

Fibre optics
XUFZ02
XUFN1p30p,
XUFN35301 and
XUFS2020 (thru-beam
system)
XUFN2p01Lpp

Lenses for increasing sensing


distance
(set of 2)

Fibre optics
XUFZ01
XUFN1p30p,
XUFN35301 and
XUFS2020 (thru-beam
system)

0.005

XUFZ06

0.001

XUFZ01

XUFZ06

Fibre optics
Focusing lens for high
precision detection. Detection of
XUFN02323
(diffuse system)
0.5 mm objects at a distance of 7 mm.
Also enables detection of objects against
a background (1)

Accessories for plastic fibres without end fittings


Description

XUFZ13, XUFZ03

Fixing clamps
(set of 2)

Mounting plane For use with

Reference

Axial

Plastic fibre optics


XUFZ

XUFZ13

Weight
kg
0.002

Frontal

Plastic fibre optics


XUFZ

XUFZ14

0.002

Lateral

Plastic fibre optics


XUFZ

XUFZ15

0.002

Axial

Plastic fibre optics


XUFZ

XUFZ03

0.002

Frontal

Plastic fibre optics


XUFZ

XUFZ04

0.002

Lateral

Plastic fibre optics


XUFZ

XUFZ05

0.002

For use with

Reference

Plastic fibre optic light


guides with M4
threaded end fittings

XUFZ210

Weight
kg
0.040

Plastic fibre optic light


guides with M6
threaded end fittings

XUFZ310

0.065

Sold in lots of

Weight
kg
0.006

XUFZ14, XUFZ04
Fixing clamps with
lens (set of 2)

XUFZ15, XUFZ05

Protection accessories
Description
Protective tubing
Length 1 m

4
5
6
7
8

Other accessories
Description
XUFZp10

Fibre trimmer

Unit
reference
XUFZ11

Plastic end adaptor, for connecting


1mm fibres to amplifiers XUDA

XUFZ08

0.002

(1) Characteristics obtained when the fibre is fully screwed into the lens (screwing depth = 4mm).
XUFZ11

XUFZ08

5/125

10

Photo-electric sensors

Cuves

OsiSense XU Application
Fibre optics for amplifiers
Accessories

Detection curves for plastic fibre optic light guides with fixing clamps

Sensing distance of fibres XUFZ9ppp fitted with fixing clamps XUFZpp

Fibre type
XUFZ910, Z920 (2 fibres L = 2 m) Sn

Clamp type
XUFZ13
150 mm

XUFZ14, Z15
100 mm

XUFZ03
800 mm

XUFZ04, Z05
600 mm

Without clamp
200 mm

XUFZ911, Z921 (2 fibres L = 2 m) Sn

220 mm

150 mm

1200 mm

900 mm

300 mm

Other fibre lengths:


5 m fibres: reduce the sensing distance by a factor of 0.7.
10 m fibres: reduce the sensing distance by a factor of 0.5.
20 m fibres: reduce the sensing distance by a factor of 0.3.
Detection curves with lens

Fixing clamp XUFZ03, Z04 or Z05 +


fibre XUFZ910 or Z920

Detection curves without lens


Fixing clamp XUFZ03, Z04 or Z05 +
fibre XUFZ911 or Z921

mm

Fixing clamp XUFZ13, Z14 or Z15 +


fibre XUFZ911 or Z921

mm

mm

mm

Sn

Sn

Sn

Fixing clamp XUFZ13, Z14 or Z15 +


fibre XUFZ910 or Z920

cm

of
beam

6
7
8
9
10

5/126

-2

cm
of
beam

-4

cm
of
beam

-6

Sn

cm
of
beam

-6

Photo-electric sensors

Dimensions

OsiSense XU Application
Fibre optics for amplifiers

Accessories
Dimensions
XUFZ01

XUFZ210

XUFZ06

M8x1

M4

M2,6

M4

3
10

1000

15

22

XUFZ310
M10x1

10

1000

3,05

(1)

7,5

12,5

7,5

3,05

2,75
9,5

12,5

7,5

12,5

15

9,5
6

15

9,5

15
6

9,5

(1)

(1)

2,75

(1)

2,75

12,5

2,75

7,5

3,05

15

(1)

15
6

XUFZ05, XUFZ15
3,05

2,75

3,05

9,5

(1)

XUFZ04, XUFZ14
2,75

XUFZ03, XUFZ13

20

15

15

9,5

9,2

M2,6

6,5

M6
across flats

XUFZ02

11

20

7,5

12,5

7,5

12,5

(1) Light beam window.

8
9
10

5/127

Photo-electric sensors

Characteristics,
references,
dimensions,
curves

OsiSense XU Application
Fibre optics for amplifier

GLASS fibres with end fittings


For diffuse and thru-beam systems

GLASS fibre optics for diffuse system


Standard sheath
External
XUYFVP: 5 mm
XUY FVER: 3 mm

3,5
9

M4x0,7

M4x0,7

6,5

6,5

2
3

11

R
10 mm

21

8x8
20

Metal reinforced sheath


XUYFVP: 5 mm
XUY FVER: 3.5 mm

R
20 mm

High temperature
sheath
XUYFVP: 5 mm
XUY FVER: 5 mm

R
30 mm

R = minimum bend radius

Applications
b Detection in high temperature environment (up to 200 C)
b Detection in aggressive environment
b Application requiring high level of performance

References

Type of end fitting

Straight

Sheath

Standard

References with 0.60 m long fibre (1)

XUYFVPSD61 XUYFVPMD61 XUYFVPTD61 XUYFVPSL61 XUYFVPML61 XUYFVPTL61

High
temperature

Standard

Metal
reinforced

High
temperature

80

80

80

80

80

80

Weight (kg)

0.040

0.045

0.052

0.042

0.056

0.056

Characteristics

400 strands per mm2

Usable diameter of fibre

1.2 mm

Ambient air temperature

Standard: - 25+ 60 C
Metal reinforced: - 25+ 120 C
High temperature :-25+ 200 C

For operation

Detection end fitting

Nickel plated brass

Materials

Metal
reinforced

Nominal sensing distance Sn (mm)

Fibre

Lateral

Fibre

50 glass

Sheath

Standard: PVC + thermo polyolefine,


Metal reinforced: spiralled metal + polyolefine
High temperature: flexible stainless steel

(1) For 1 m long fibre, replace 61 in the reference by 101. Example: XUYFVPSD61 becomes XUYFVPSD101 for a 1 m long fibre.
For 1.5 m long fibre, replace 61 in the reference by 151. Example: XUYFVPMD61 becomes XUYFVPMD151 for a 1.5 m long fibre.
For 2 m long fibre, replace 61 in the reference by 201. Example: XUYFVPTD61 becomes XUYFVPTD201 for a 2 m long fibre.

Detection and attenuation curves

XUYFVPpp61
mm
15
10
5

50

100 % D

5
10
15

10

0
-25
-50

Material influence
Attenuation (%)

Bending influence
Attenuation (%)

Attenuation related to length


Attenuation (%)

0
-10
-20
-30
-40
-50
-60

-75
0

Length of fibres

References of amplifiers:
page 5/136

5/128

5 m

10

20
Bend radius

mm

1
0,9
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
0

1 White paper
2 Wood, beige
cardboard
3 Black paper
4 Raw steel
5 Raw aluminium

Photo-electric sensors

20

M4x0,7

21

2,5

References,
dimensions,
curves

OsiSense XU Application
Fibre optics for amplifier

GLASS fibres with end fittings


For diffuse and thru-beam systems

6,5

2
6,5

21

M4x0,7

89

2,5

4
Extended

Pliable

Standard

Metal reinforced

High temperature

Standard

Metal reinforced

XUYFVPSA61 (1)

XUYFVPMA61 (1)

XUYFVPTA61 (1)

XUYFVPSC61 (1)

XUYFVPMC61 (1)

High temperature
XUYFVPTC61 (1)

80

80

80

80

80

80

0.041

0.046

0.053

0.043

0.057

0.057

400 strands per mm2


1.2 mm

Standard: - 25+ 60 C
Metal reinforced: - 25+ 120 C
High temperature: - 25+ 200 C
Nickel plated brass
50 glass
Standard: PVC + thermo polyolefine,
Metal reinforced: spiralled metal + polyolefine
High temperature: flexible stainless steel

(1) For 1 m long fibre, replace 61 in the reference by 101. Example: XUYFVPSA61 becomes XUYFVPSA101 for a 1 m long fibre.
For 1.5 m long fibre, replace 61 in the reference by 151. Example: XUYFVPMA61 becomes XUYFVPMA151 for a 1.5 m long fibre.
For 2 m long fibre, replace 61 in the reference by 201. Example: XUYFVPTA61 becomes XUYFVPTA201 for a 2 m long fibre.

8
9
10
References of amplifiers:
page 5/136

5/129

Photo-electric sensors

References,
dimensions,
curves

OsiSense XU Application
Fibre optics for amplifier

GLASS fibres with end fittings


For diffuse and thru-beam systems

GLASS fibre optics for thru-beam system

Standard sheath
External
XUYFVP: 5 mm
XUY FVER: 3 mm

R
10 mm

14

21

11

Metal reinforced sheath


XUYFVP: 5 mm
XUY FVER: 3.5 mm

R
20 mm

6,5

M4x0,7

3,5
4

8x8

M4x0,7

20

High temperature sheath


XUYFVP: 5 mm
XUY FVER: 5 mm

R
30 mm

R = minimum bend radius

Applications
b Detection in high temperature environment (up to 200 C)
b Detection in aggressive environment
b Application requiring high level of performance

References

Type of end fitting

Straight

Sheath

Standard

Standard

Metal
reinforced

High
temperature

References with 0.6 m long fibre (1)

XUYFVERSD61 XUYFVERMD61 XUYFVERTD61 XUYFVERSL61 XUYFVERML61 XUYFVERTL61


200

200

200

200

200

200

Weight (kg)

0.042

0.046

0.060

0.052

0.061

0.075

Fibre

400 strands per mm2

Usable diameter of fibre

1.2 mm

Ambient air temperature

Standard: - 25+ 60 C,
Metal reinforced: - 25+ 120 C
High temperature: - 25+ 200 C

For operation

Detection end fitting

Nickel plated brass

Materials

High
temperature

Nominal sensing distance Sn (mm)

Characteristics

Lateral
Metal
reinforced

Fibre

50 glass

Sheath

Standard: PVC + thermo polyolefine


Metal reinforced: spiralled metal + polyolefine
High temperature: flexible stainless steel

(1) For 1 m long fibre, replace 61 in the reference by 101. Example: XUYFVERSD61 becomes XUYFVERSD101 for a 1 m long fibre.
For 1.5 m long fibre, replace 61 in the reference by 151. Example: XUYFVERMD61 becomes XUYFVERMD151 for a 1.5 m long fibre.
For 2 m long fibre, replace 61 in the reference by 201. Example: XUYFVERTD61 becomes XUYFVERTD201 for a 2 m long fibre.

Detection and attenuation curves

XUYFVERpp61
mm
45
30
15

50

100 % D

15
30
45

10

Bending influence
Attenuation (%)

Attenuation related to length


Attenuation (%)

0
-10

0
-10
-20
-30

-20

-40

-30

-50
-60
0

3
4
5 m
Length of fibres

References of amplifiers:
page 5/136

5/130

Material influence

10

20
Bend radius

mm

1
0,9
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
0

1 White paper
2 Wood, beige
cardboard
3 Black paper
4 Raw steel
5 Raw aluminium

Photo-electric sensors

References,
dimensions,
curves

OsiSense XU Application
Fibre optics for amplifier

GLASS fibres with end fittings


For diffuse and thru-beam systems

1
M4x0,7

89

2,5

21

21

20

2,5

M4x0,7

4
Extended

Pliable

Standard

Metal reinforced

High temperature

Standard

Metal reinforced

XUYFVERSA61 (1)

XUYFVERMA61 (1)

XUYFVERTA61 (1)

XUYFVERSC61 (1)

XUYFVERMC61 (1)

High temperature
XUYFVERTC61 (1)

80

80

80

80

80

80

0.043

0.047

0.061

0.053

0.061

0.076

400 strands per mm2


1.2 mm

Standard: - 25+ 60 C,
Metal reinforced: - 25+ 120 C
High temperature: - 25+ 200 C
Nickel plated brass
50 glass
Standard: PVC + thermo polyolefine
Metal reinforced: spiralled metal + polyolefine
High temperature: flexible stainless steel

(1) For 1 m long fibre, replace 61 in the reference by 101. Example: XUYFVERSA61 becomes XUYFVERSA101 for a 1 m long fibre.
For 1.5 m long fibre, replace 61 in the reference by 151. Example: XUYFVERMA61 becomes XUYFVERMA151 for a 1.5 m long fibre.
For 2 m long fibre, replace 61 in the reference by 201. Example: XUYFVERTA61 becomes XUYFVERTA201 for a 2 m long fibre.

8
9
10
References of amplifiers:
page 5/136

5/131

Photo-electric sensors

References

OsiSense XU Application
Fibre optics for amplifier

GLASS fibres with end fittings


For diffuse and thru-beam systems

Accessories

Focusers for diffuse system fibre optics


Description

For use with

Focusers
for pinpoint reading of reference marks,
contrasts, faults, etc.

XUY FVERSD61
XUY FVERMD61
XUY FVERTD61

Nominal sensing
distance (Sn)

Unit
reference

Weight

10

XUY1120

0.003

30

XUY1125

0.004

Nominal sensing
distance (Sn)

Unit
reference

Weight

mm

kg

Focusers for thru-beam system fibre optics


Description
hhhh

For use with

mm
Focusers
for increasing sensing distances
(sold in lots of 2)

(1) 70 max.
(2) 250 max.

4
5
6
7
8
9
10
References of amplifiers:
page 5/136

5/132

XUY FVERSD61
XUY FVERMD61
XUY FVERTD61

kg

800

XUY 1121 (1)

0.004

3000

XUY 1124 (2)

0.012

800

XUY 1122 (1)

0.006

Photo-electric sensors

Dimensions

OsiSense XU Application
Fibre optics for amplifier

GLASS fibres with end fittings


For diffuse and thru-beam systems

Focusers

XUY1120

XUY1125

M4x0,7

35

10

M4x0,7

6,5
XUY1124

M4x0,7

M4x0,7

8,5

XUY 1122R
20

18

30

8x8
11

XUY1121

8,5

17

25

6,5

M4x0,7

4
5
6
7
8
9
10
References of amplifiers:
page 5/136

5/133

Photo-electric sensors

References,
curves

OsiSense XU Application
Fibre optics for amplifier

Ecofibre system in PLASTIC for customer assembly

Ecofibre concept
Assemble your own fibre
optics.

End fittings
Optic

5,5
M8x1

28

10

Fibres without
end fitting

Optic
3
5

16

16

4
5
6
7

End fittings
Nominal sensing distance Sn (mm)

70

200

800

Reference

XUYA110

XUYA210

XUYA211

Weight (kg)

0.009

0.004

0.004

Fibres without end fitting


Type of fibre

Single fibre, plastic, single strand

Length (m)

10

50

Usable diameter (mm)

External diameter (mm)

2.2

2.2

2.2

Reference

XUY A005

XUYA00510

XUYA00550

Weight (kg)

0.006

0.042

0.220

8
Curves

End fittings

XUYA110

XUYA210

cm

XUYA211

cm

cm

10

40

20

4
3
2

10

References of amplifiers:
page 5/136

5/134

0,5 0,5 0,5

Photo-electric sensors

References,
curves

OsiSense XU Application
Fibre optics for amplifier

Ecofibre system in PLASTIC for customer assembly

32

6M6x1

30

310 8

M6x1

25

10

13,5

M6x1

Optic

M12x1

08 (1)

Optic

8x8

Optic

35

25

End fitting for passing through


partition

4
(1) 6.2 cut-out

1200

4000

1200

XUYA212

XUYA213

XUYA220

XUYA310

0.011

0.045

0.018

0.017

Single fibre, plastic, multistrand

Dual fibre, plastic, single strand

5
6
7

2.2

2.2

XUYAU005

XUYFP2BRINA005B

0.006

0.080

8
XUYA212

XUYA213

XUYA220
cm

cm

cm

80

400

40

200

80

40

10
3

References of amplifiers:
page 5/136

5/135

Photo-electric sensors

OsiSense XU Application
Amplifiers for plastic or glass fibre optics

Amplifiers for plastic fibre optics (1)

524696

524698

References,
characteristics

Sensing distance (Sn) Function


m

1
t

NO/NC
PNP/NPN Pre-cabled
XUY AFP966S
dpg. on wiring
M8 connector XUY AFPCO966S

NO/NC
PNP/NPN Pre-cabled
XUY AFP946S
programmable
M8 connector XUY AFPCO946S

Amplifiers for glass fibre optics


Sensing distance (Sn) Function
m

XUY AFP946S

524697

524699

XUY AFP966S

Output

Connection

Reference

NO/NC
PNP/NPN Pre-cabled
XUY AFV966S
dpg.on wiring
M8 connector XUY AFVCO966S

NO/NC
PNP/NPN Pre-cabled
programmable
M8 connector

Accessories
Description

0.056

0.124
0.056

Weight
kg
0.116
0.047

Details

XUY AFV946S

0.124

XUY AFVCO946S

0.047

Length of cable Reference


m

t
SET
t

Pre-wired M8
connector

Weight
kg

XZC P0941L2

0.080

Elbowed (90) 2

XZC P1041L2

0.080

Straight

XZC P0941L5

0.180

Elbowed (90) 5

XZC P1041L5

0.180

Straight

O
LO-D

(1) Fibre trimmer included


(2) Indication of level by bargraph, adjustment by pressing button
(3) Fine mode or standard mode, adjustment using teach

5
XUY AFV966S

XUY AFV946S

Characteristics

Sensor type

Product certifications
Connection
Nominal sensing distance
(Sn)
Type of transmission
Sensitivity adjustment
Degree of protection
Ambient air temperature
Materials
Immunity to ambient light

0.124

Adjustment using teach mode (3)

Weight
kg

Adjustment using +/- button (2)


Depending on fibre

Depending
on fibre

Reference

Adjustment using teach mode (3)


Depending on fibre

SET
t
O
LO-D

Connection

Adjustment using +/- button (2)


Depending on fibre

Output

Connector
Pre-cabled

LED
Modulation frequency
Conforming to IEC60529
For storage
For operation
Incandescent bulb
Natural light

Rated supply voltage


Voltage limits (including ripple)
Current consumption, no-load
Switching capacity
Voltage drop, closed state
Maximum switching frequency
External input (5)
Active
Delays
Output time delay (5)

Inactive
Response and recovery
Range

XUY AFp9p6S

XUY AFCO9p6S

e, cULus (4)

Length: 2 m
Depending on fibre optic used

M8, 4-pin

Lux
Lux
V
V
mA
mA
V
kHz
V

Red LED
8 kHz
Using teach (fine mode or standard mode) and/or +/- button, depending on model
IP65
- 20...+ 80
0...+ 60
Polycarbonate
10 000
20 000
c 12...24 with protection against reverse polarity
c 10...30
< 40
100 with overload and short-circuit protection
<2
<1
< 1.4

>3

ms
s

< 0.5
05 in 11 adjustment increments

C
C

ms
First increment 40 ms then 500 ms for each press
Duration of each increment
(4) This product is UL Listed if supplied by a class II or isolated supply delivering c 30 V max. (isolated transformer for example) and protected by a UL fuse rated
at 3 A max.
(5) Only for models with teach mode.

10

b Applications using plastic fibre optics


v Monitoring position or presence of parts
on an assembly or packing machine
v Detection of objects on small conveyor
v Use of fibre optics in vibratory environments (robot arms)
v Detection of reference and colour marks in packaging

5/136

b Applications with glass fibre optics


v Monitoring position or presence of parts
on an assembly or packing machine
v Detection of presence of parts in a plastic mould
v Detection in aggressive environments
v Detection of items exiting an oven (high temperature fibres)

Photo-electric sensors

Presentation,
dimensions,
schemes

OsiSense XU Application
Amplifiers for plastic or glass fibre optics

Presentation

XUYAFp, adjustment using button

XUYAFp, adjustment using teach mode

Detection

Detection

Indication of the level of


adjustment

Dirty optics, limit of detection, alignment assistance

Keypad locking

Time delay active

Sensitivity increase

Action keypad, keypad locking

Sensitivity decrease

2
3
4

Automatic adjustment of the threshold, access to special


functions

Sensitivity increase, direct/inverse output, time delay


increase

Sensitivity decrease, On-delay, Off-delay inversion, time


delay decrease

Dimensions

XUY AFP966S/AFPCO966S

Mounting on 35 mm 5 rail

(1)

3
4

XUY AFV966S/AFVCO966S

Mounting on 35 mm 5 rail

5
60

25,4

25,4

60

20

20

5,5

10

(1)

SET

SET

2x4,1

6,7

6,7

2x4,1

30

13

30

Wiring schemes

XUY AFP966/AFV966

XUY AFP946/AFV946
BN c 10/30 V

Microprocessor

WH

Connected to +: direct function


Connected to : inverse function

2
1

BK
P

0V

Thru-beam and diffuse system detection

M8 connector
BN c 10/30 V

Microprocessor

BK
BU

Application examples

13

(1) Glass fibre optic: 3 mm

(1) Plastic fibre optic: 2.2 mm

BU

0V

WH

Remote teaching
If not used: connect to +

4
3

Pin
N

Colour

1 BN

Brown

2 WH White
3 BU

Blue

4 BK

Black

8
9

Thru-beam system detection

10

5/137

Photo-electric sensors

References,
characteristics

OsiSense XU, general purpose

DC supply. Solid-state output


With stability LED and alarm output (1)

Compact design

1
2
3

System

Thru-beam 1

Polarised reflex 2

Diffuse with background


suppression 3

Type of transmission
Nominal sensing distance (Sn) / maximum

Infrared
50 m / 60 m

Red
6m/9m
(with 50 x 50 mm reflector)

Infrared
1.2 m / 1.2 m

XUC2AKSAL2 (2)

XUC9AKSAL2 (3)

XUC8AKSNL2

0.520

0.280

0.260

XUC2AKSAM12 (2)

XUC9AKSAM12 (3)

XUC8AKSNM12

0.400

0.220

0.200

References of sensors
Pre-cabled versions

3-wire,
PNP or NPN programmable
Weight (kg)

NO or NC programmable
function

Connector versions
3-wire,
PNP or NPN programmable
Weight (kg)

NC or NO programmable
function

Characteristics

5
6
7

Product certifications
Ambient air temperature

For operation
For storage
Conforming to IEC60068-2-6
Conforming to IEC60068-2-27
Conforming to IEC60529

Vibration resistance
Shock resistance
Degree of protection
Materials
Connection

Pre-cabled
Connector

Rated supply voltage


Voltage limits
Switching capacity (sealed)
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Delays

First-up: 15 ms; response: 1 ms; recovery: 1 ms

Function table

8
9

Function

Output state (PNP or NPN) indicator: yellow LED


(illuminated when sensor output is ON)

Thru-beam and reflex systems


No object present
Object present in
in the beam
the beam

NC

Function Diffuse
No object present
in the beam
NO

NO

NC

(1) Alarm output only applicable to thru-beam and reflex system sensors.
(2) Reference for both transmitter and receiver for thru-beam system sensors.
(3) 50 x 50 mm reflector included with reflex system sensors.
(4) Sensors available with 5 m cable. To order, change the reference suffix L2 to L5.
Example: Transmitter + receiver XUC2AKSAL2 with 2 m cable becomes XUC2AKSAL5 with 5 m cable.

Description
1 2

10

e, UL, CSA
- 25+ 55 C
- 40+ 70 C
7 gn (f = 1055 Hz)
20 gn, duration 11 ms
IP 67 (IP 30 with cover open). NEMA 3, 4, 4X, 6, 6P, 12, 13
Case: PC, lenses: PMMA, cable: PvR
Diameter 6 mm cable, length 2 m (4), wire c.s.a.: 5 x 0.34 mm2
M12 male connector, 4-pin (suitable female connectors, including pre-wired versions, see page
9/44)
c 1224 V with protection against reverse polarity
c 1038 V (including ripple)
100 mA with overload and short-circuit protection
1.5 V
Thru-beam (transmitter and receiver): 50 mA, reflex and diffuse: 35 mA
500 Hz

Light on

4
3

5/138

Dark on

PNP

5
NPN

Yellow LED, output


Red LED, stability
Sensing distance adjustment potentiometer
NC/NO programming switch
PNP/NPN programming switch

Object present
in the beam

Photo-electric sensors

Curves,
dimensions,
schemes

OsiSense XU, general purpose

DC supply. Solid-state output


With stability LED and alarm output

Curves

Detection curves
Thru-beam system

Reflex system

of beam (cm)

2 1

10

16 mm

8
4

60 m

-5

9 m

0,2

Sn 50 m

1,30

-4
-8

-10

-60

Diffuse

of beam (cm)

of beam (cm)
60

Sn 1,10 m
Sn 1,30 m

Sn 6 m

Object 20 x 20 cm 1 White 90% 2 Black 6%

Excess gain curves (ambient temperature: + 25 C)


Thru-beam system

Variation of usable sensing distance


Reflex system

gain
10 000

Diffuse with background suppression

gain

1000

40
30
20

100

10

A 0,05

1,10 1,50
1,30

S (m)

A-B: Object reflection coefficient

10

10

50 100 D (m)

4 6 10

D (m)

XUCpAKSpM12

20
18

(2)
1/2" NPSM
35

(2)
(3)

35

34

23

Side view, cover hinged open


150

80

34

Wiring schemes (3-wire c)

BN/1

(3) M12 connector.


Tightening torque 2 N.m.

NO programmed (no object present)

NC programmed (no object present)

Thru-beam receiver and reflex Diffuse


PNP output
PNP output

Thru-beam receiver and reflex Diffuse


PNP output
PNP output

BN/1

BU/3

NPN output

BK/4
BU/3
BN/1
BK/4

BN/1
BK/4
BU/3

NPN output

BN/1

BN/1

NPN output

BN/1
BK/4

BU/3

BU/3

BN/1
BK/4
BU/3

BK/4
BU/3

BK/4

BU/3

5
6

(1) 2 elongated holes 5.5 x 11 for fixing by front face (M5 screws included)
(2) M30 x 1.5 threaded boss (and 1/2" NPSM inside for XUC pAKSpLp), for direct mounting. Max. tightening torque: 25 N.m.

Transmitter

Sensing range
Non sensing zone

100

95,1

(1)

5,5

20

23

43,5

(1)

45

44

3,7

45

44

18

3,7

XUCpAKSpLp

108

95,1

Dimensions

Black 6%
Grey 18%
White 90%

43,5

1
0,1 0,2 0,4

5,5

NPN output

BN/1
BK/4

BU/3

Alarm output, alarm signal and verification of correct operation (for thru-beam and reflex systems only)
PNP

NPN
BN/1

BN/1
WH/2

WH/2
BU/3

BU/3

Red
LED
Alarm
signal

State 0: output off


State 1: output on
t = 160 ms

Beam break test (for thru-beam transmitter only)


Beam made

Beam broken
BN/1

BN/1

VI/2
BU/3

VI/2
BU/3

Output 1,15
1
signal 0,85

DEL off

Red LED

DEL on
Optimum
alignment

Cable connections and connector schemes (see connections on page 9/44)


XUCpAKSpLp
()
BU
(+)
BN
(OUT)
BK
Alarm
WH
Test
VI

(Blue)
(Brown)
(Black)
(White)
(Violet)

XUCpAKSpM12
Thru-beam transmitter
4

( )

(+) 1

Test input

Thru-beam receiver, reflex


and diffuse
4

(+) 1

Output

( )

Alarm output
(except diffuse)

5/139

10

Photo-electric sensors

References,
characteristics

OsiSense XU, general purpose


AC or DC supply
1 CO time delay relay output
With stability LED

Compact design

1
2
3

System

Thru-beam 1

Polarised reflex 2

Diffuse with background


suppression 3

Type of transmission
Nominal sensing distance (Sn) / maximum

Infrared
50 m / 60 m

Red
6m/9m
(with 50 x 50 mm reflector)

Infrared
1.2 m / 1.2 m

XUC2ARCTL2 (1)

XUC9ARCTL2 (2)

XUC8ARCTL2

0.520

0.280

0.260

XUC2ARCTU78 (1)

XUC9ARCTU78 (2)

XUC8ARCTU78

0.400

0.220

0.200

References of sensors
Pre-cabled versions

5-wire

NO or NC programmable
function

Weight (kg)

Connector versions
5-wire

NO or NC programmable
function

Weight (kg)

Characteristics

5
6
7
8

Product certifications
Ambient air temperature

For operation
For storage
Conforming to IEC60068-2-6
Conforming to IEC60068-2-27
Conforming to IEC60529

Vibration resistance
Shock resistance
Degree of protection
Materials
Connection

Pre-cabled
Connector

Rated supply voltage


Voltage limits
Switching capacity
Maximum voltage on output relay contacts
Power consumption
Maximum switching frequency
Electrical durability
Time delay
Delays
Function table

e, UL, CSA
- 25+ 55 C
- 40+ 70 C
7 gn (f = 1055 Hz)
20 gn, duration 11 ms
IP 67 (IP 30 with cover open). NEMA 3, 4, 4X, 6, 6P, 12, 13
Case: PC, lenses: PMMA, cable: PvR
Diameter 6 mm cable, length 2 m (3), wire c.s.a.: 5 x 0.34 mm2
7/8"-16UN male connector, 5-pin (suitable female pre-wired connectors XZCP1764Lp) (4)
z 24240 V
z 20264 V
3 A (cos j = 1) for a contact life of 0.5 million operating cycles at an operating rate of 1
operating cycle per second, at 250 V
a 250 V
2W
20 Hz
> 5 x 105 operating cycles (cos j = 1)
Monostable, on-delay or off-delay (programmable). 2 adjustable ranges, covering 0 to 15 seconds

First-up: 60 ms; response: 25 ms; recovery: 25 ms


Function Thru-beam and reflex systems
Func- Diffuse
tion
No object present in Object present in the
No object present in
the beam
beam
the beam
NC
NO
BK
BK
BK
GY
GY
GY
WH
WH
WH

Output state of relay contacts indicator: yellow LED


(illuminated when relay energised)

NO

Relay energised

Relay de-energised

BK
WH

BK
WH

GY

Relay de-energised

GY

NC

Relay energised

Object present in the


beam
BK
WH

GY

Relay de-energised

Relay energised

BK
WH

BK
WH

GY

Relay energised

GY

Relay energised

(1) Reference for both transmitter and receiver for thru-beam system sensors.
(2) 50 x 50 mm reflector included with reflex system sensors.
(3) Sensors available with 5 m cable. To order, change the reference suffix L2 to L5.
Example: Transmitter + receiver XUC2ARCTL2 with 2 m cable becomes XUC2ARCTL5 with 5 m cable.
(4) To complete the reference for a pre-wired female connector with a 2 m, 5 m or 10 m cable, replace the p by 2, 5 or 10 respectively. Example, pre-wired connector
with 2 m cable: XZCP1764L2.

Description

T1

10

T2
02 s

T2

T1

1 2
6
3

5/140

015 s

9
T2
T1

LED
Potentiometers
3 Sensing distance
1 Yellow LED,
output
adjustment
2 Red LED, stability 4 T1 time delay
adjustment
5 T2 time delay
adjustment

Switches
6 NC/NO programming
7 T1 setting range
8 T2 setting range
9 Normal time delay (on-delay or offdelay) or monostable

Photo-electric sensors

Curves,
dimensions,
schemes

OsiSense XU, general purpose

AC or DC supply
1 CO time delay relay output
With stability LED

Curves

Detection curves
Thru-beam system

Reflex system
of beam (cm)

of beam (cm)
60

of beam (cm)

2 1

10

16 mm

8
4

60 m

9 m

0,2

-5

Sn 50 m

1,30

-4
-8

-10

-60

Diffuse

Sn 1,10 m
Sn 1,30 m

Sn 6 m

Object 20 x 20 cm 1 White 90% 2 Black 6%

Excess gain curves (ambient temperature: + 25 C)


Thru-beam system

Variation of usable sensing distance


Reflex system

gain
10 000

Diffuse with background suppression

gain

1000

40
30
20

100

10

A 0,05

10

1,10 1,50
1,30

S (m)

A-B: Object reflection coefficient


50 100 D (m)

Dimensions

4 6 10

D (m)

XUCpARCTU78

95,1

(1)
23

18

(2)

18

5,5

20

20

23

43,5

(1)

45

44

3,7

45

44

(2)

1/2" NPSM
34

35

35

Side view, cover hinged open


150

3,7

XUCpARCTLp

(3)

NO programmed (no object present)

BN/4

BN/4

GY/3

BU/2

Output1,15
1
signal 0,85

DEL off

Red LED

DEL on
Optimum
alignment

Time delays

WH/5
GY/3
BK/1
BU/2

XUCpARCTLp
z
BU
z
BN
Relay common GY
NO contact
BK
NC contact
WH

Beam broken

NC function

Relay ON
Relay OFF

NO function

Relay ON
Relay OFF

GY/3

BN/4

WH/5
BK/1

GY/3

BU/2

WH/5
BK/1

BU/2

Connector scheme

(Blue)
(Brown)
(Grey)
(Black)
(White)

XUCpARCTU78
Thru-beam transmitter

Thru-beam receiver, reflex


and diffuse

3 Relay common

3
2

4
5

Normal time delay

Time delay adjustment


Beam intact
Receiver state

BN/4

BN/4

Cable connections

Thru-beam and reflex systems

(3) 7/8" connector.


Tightening torque 3 N.m.

Thru-beam receiver and reflex Diffuse

BU/2

Verification of correct operation

80

NC programmed (no object present)

Diffuse

WH/5
BK/1

34

Wiring schemes (5-wire z)

Thru-beam receiver and reflex

(1) 2 elongated holes 5.5 x 11 for fixing by front face (M5 screws included)
(2) M30 x 1.5 threaded boss (and 1/2" NPSM inside for XUC pARCTLp), for direct mounting. Max. tightening torque: 25 N.m.

Transmitter

Sensing range
Non sensing zone

100

10

108

91,5

Black 6%
Grey 18%
White 90%

43,5

1
0,1 0,2 0,4

5,5

NC 5

1 NO

Monostable time delay

T1 = time delay on trip On-delay


T2 = time delay on reset Off-delay
T1 = T2 = 0
T1 0, T2 0
T1

T2

T2

T1

T1 = time delay on trip On-delay


T2 = monostable period
T1 = 0, T2 0
T1 0, T2 0
T1

T2

T2

T1

T2

T2

T
T2

T2

T1

T2

T1

T1

T2 T1

T2

T2

5/141

10

References, characteristics Photo-electric sensors

OsiSense XU Application, conveying series


Compact design
3-wire DC, solid-state output

Compact design

Pre-cabled and connector versions

2
3
4
5

System

Thru-beam 1

Type of transmission
Nominal sensing distance (Sn)

Infrared
8m

References

Red
4m
(with 80 mm
reflector)

Infrared
0.7 m

Pre-cabled
Connector

XUL H083534
XUL H083534D

XUL H06353
XUL H06353D

XUL H043539
XUL H043539D

XUL H703535
XUL H703535D

3-wire,
NPN

NO or NC
programmable
function

Connection

Pre-cabled
Connector

XUL J083534
XUL J083534D

XUL J06353
XUL J06353D

XUL J043539
XUL J043539D

XUL J703535
XUL J703535D

Transmitter

Connection
Connection

XUL K0830
XUL K0830D
0.195
0.135

Weight (kg)

Pre-cabled
Connector
Pre-cabled
Connector

Product certifications
Ambient air temperature

Connection

For operation
For storage
Conforming to IEC60068-2-6
Conforming to IEC60068-2-27
Conforming to IEC60529
Conforming to NFC20-010
Pre-cabled
Connector
Case
Lenses
Cable

Rated supply voltage


Voltage limits
Switching capacity (sealed)
Voltage drop, closed state
Current consumption, no-load
Maximum switching frequency
Delays
First-up
Response
Recovery
Function table

Output state (PNP or NPN) indicator


(illuminated when sensor output is ON)

10

6m
(with 80 mm
reflector)

Connection

Materials

Diffuse 3

NO or NC
programmable
function

Vibration resistance
Shock resistance
Degree of protection

Polarised reflex 2

3-wire,
PNP

Characteristics

Reflex 2

Function

e. Special H7 version: UL, CSA


- 25+ 55 C
- 40+ 70 C
7 gn, amplitude 2 mm (f = 10...55 Hz)
20 gn, duration 11 ms
IP67
IP671
Diameter 6 mm, length 2 m (1)
Wire c.s.a.: 4 x 0.34 mm2 (2 x 0.34 mm2 for thru-beam transmitter)
M12
ABS
PMMA
PVC
c 1224 V with protection against inversion of the 3 wires
c 1030 V (including ripple)
y 200 mA with overload and short-circuit protection
y 1.5 V
y35 mA
250 Hz
y 15 ms
y 2 ms
y 2 ms
Thru-beam and reflex systems
No object present
Object present
in the beam
in the beam

NC

Function Diffuse system


No object present
in the beam
NO

NO

NC

(1) For a sensor with a 5 m long cable add L05 to the end of the reference; for a 10 m long cable add L10 to the end of the reference.
Example: sensor XUL H083534 with 5 m cable becomes XUL H083534L05
Accessories:
page 5/158

5/142

Object present
in the beam

References, characteristics Photo-electric sensors

OsiSense XU Application, conveying series

Compact design
2-wire AC, solid-state output

Compact design
Pre-cabled and connector versions

1
1

System
Type of transmission
Nominal sensing distance (Sn)

References
2-wire

NC
function

Connection

NO
function

Connection

Weight (kg)

Connection

Characteristics
Product certifications
Ambient air temperature
Vibration resistance
Shock resistance
Degree of protection
Connection
Materials

Rated supply voltage


Voltage limits
Switching capacity (2)
Sealed

Pre-cabled
Connector
Pre-cabled
Connector
Pre-cabled
Connector

For operation
For storage
Conforming to IEC60068-2-6
Conforming to IEC60068-2-27
Conforming to IEC60529
Conforming to NFC20-010
Pre-cabled
Connector
Case
Lenses
Cable

Maximum

Minimum
Inrush
Voltage drop, closed state
Residual current, open state
Maximum switching frequency
Delays
First-up
Response
Recovery
Function table

Output state indicator


(illuminated when sensor output is ON)

Function

Reflex 1
Infrared
6m
(with 80 mm reflector)

Polarised reflex 1
Red
4m
(with 80 mm reflector)

Diffuse 2
Infrared
0.7 m

XUL A06021
XUL A06021K
XUL A06011
XUL A06011K
0.195
0.135

XUL A040219
XUL A040219K
XUL A040119
XUL A040119K

XUL A700115
XUL A700115K
XUL A700215
XUL A700215K

4
5

e. Special H7 version: UL, CSA


- 25+ 60 C
- 40+ 80 C
7 gn, amplitude 2 mm (f = 10...55 Hz)
20 gn, duration 11 ms
IP65
IP651
Diameter 6 mm, length 2 m (1), wire c.s.a.: 2 x 0.34 mm2
1/2"-20UNF
ABS/PC
PMMA
PVC
a or c 24240 V
a or c 20264 V
a 12 or c 12 (resistive load): 0.5 A/240 V
a 140 (inductive load): 0.3 A/240 V
c 13 (inductive load): 0.1 A/240 V; 0.2 A/110 V; 0.5 A/48 V
5 mA
3000 mA
y3 V (I = 0,10.5 A); y5.5 V (I = 10 mA); y10 V (I = 5 mA)
y1.7 mA (on a); y1.5 mA (on c)
20 Hz
y 300 ms
y 20 ms
y 20 ms
Reflex system
No object present
in the beam

NC

Function Diffuse system


No object present
in the beam
NO

NO

NC

Object present
in the beam

6
7
8
Object present
in the beam

(1) For a sensor with a 5 m long cable add L05 to the end of the reference; for a 10 m long cable add L10 to the end of the reference.
Example: sensor XUL A06021 with 5 m cable becomes XUL A06021L05
(2) These sensors do not incorporate overload or short-circuit protection and therefore, it is strongly advised to connect a quick-blow fuse in series with the load
(see page 2/106).

Accessories:
page 5/158

5/143

9
10

Photo-electric sensors

Curves,
dimensions,
schemes

OsiSense XU Application, conveying series

AC and DC supply
Solid-state output
Pre-cabled and connector versions

Detection curves

Thru-beam system

Reflex system

of beam
mm

of beam
cm

Diffuse system
of beam
mm
10
8
6
4
2

10

10

16 mm

0,2

-5

-5

-10

-2
-4
-6
-8
-10

(1)

-10
Sn

8m

(2)

0,1

0,3

Sn

0,7 m

0,7 m

Object 20 x 20 cm
White 90%

(1) Polarised
(2) Infrared

Excess gain curves (ambient temperature: + 25 C)


Thru-beam system

Reflex system

gain

gain

500

50

0,1 0,2 0,4 0,8


0,6 1

2 3

5 8 10 13
4 6 9 D (m)

0,7 1,5
1
2

68

20

10

With reflector XUZ C80


1 Infrared
2 Polarised

30

D (m)

Diffuse system
gain
Min.

10

5
4

3
2

1
0 10 20 30 40 50 60 70 80

Object 20 x 20 cm
White 90 %

ON
(OFF)

Potentiometer adjustment

OFF
(ON)

1/2

Max.

D (cm)

Object 20 x 20 cm
1 White 90 %
2 grey 18 %

0 10 20 30 40 50 60 70 80 D (cm)

Dimensions
(2)

18

(3)

(5)

28 (4)

70

12

14

(5)

20,6

45

30

(1) Optical axis


(2) Sensitivity potentiometer (diffuse model)
(3) Output LED indicator
Accessories:
page 5/158

5/144

(4) Front fixing ( 3 screws and inserts included)


(5) 1 elongated hole 4.1 x 10 and 1 x 4.1
(6) 1 elongated hole 3.1 x 10 and 1 x 3.1

12,5

39

(6)

28
30

11

(6)

4,5

(1)

10

17
7

35

54,5

10

30
25
15
10
7

100
50

80

Photo-electric sensors

Curves,
dimensions,
schemes

OsiSense XU Application, conveying series

AC and DC supply
Solid-state output
Pre-cabled and connector versions

Schemes

Wiring schemes (3-wire c)


Transmitter

NO programmed (no object present)


Thru-beam receiver and
Diffuse
reflex
PNP output
PNP output
BN/1
BU/3

NPN output

NC programmed (no object present)


Thru-beam receiver and
Diffuse
reflex
PNP output
PNP output

BN/1

OG/2

BK/4
BU/3
OG/2

BN/1

BN/1

BN/1

BK/4

BK/4
BU/3

BK/4
BU/3
OG/2

BN/1
BK/4

BN/1
BK/4
BU/3
OG/2

OG/2

BU/3

NPN output

OG/2
BN/1
BK/4

NPN output

BU/3

OG/2
BN/1
BK/4
BU/3

NPN output

BU/3
OG/2

Connector scheme (sensor connector pin view)

1 (+)
Programming

4 Output

2
3 ()

Wiring schemes (2-wire a or c)


NO function (no object present)
Reflex
Diffuse
BN/2
BU/3

NC function (no object present)


Reflex
Diffuse
BN/2

BN/2

BN/2

BU/3

BU/3

BU/3

6
Attention: it is essential to connect a load in series with the sensor
Connector scheme (sensor connector pin view)
Solid-state output (reflex and diffuse system)
2

8
9
10
Accessories:
page 5/158

5/145

References, characteristics Photo-electric sensors

OsiSense XU Application, conveying series


Compact design
5-wire AC or DC, 1 CO relay output

Compact design

1
2

2
3
4

System

Thru-beam 1

Type of transmission

Infrared

Nominal sensing distance (Sn)

8m

6m
(with 80 mm
reflector)

4m
(with 80 mm
reflector)

0.25 m (fixed sensing


distance)

XUL M080314
XUL M0600
0.195

XUL M06031

XUL M040319

XUL M300318

Product certifications
Ambient air temperature
Vibration resistance
Shock resistance
Degree of protection

6
7
8

NC function

For operation
For storage
Conforming to IEC60068-2-6
Conforming to IEC60068-2-27
Conforming to IEC60529
Conforming to NFC20-010

Connection
Materials

Case
Lenses
Cable

Rated supply voltage


Voltage limits
Switching capacity
Maximum voltage on output relay contacts
Current consumption, no-load
Maximum switching frequency
Delays
First-up
Response
Recovery
Function table
Output state of relay contact indicator
(illuminated when relay energised)

Function
NC

Red

Diffuse with
background
suppression 2
Infrared

e. Special H7 version: UL, CSA


- 25+ 55 C
- 40+ 70 C
7 gn, amplitude 2 mm (f = 10...55 Hz)
20 gn, duration 11 ms
IP67
IP671
Pre-cabled: diameter 6 mm, length 2 m (1), wire c.s.a.: 5 x 0.34 mm2 (2 x 0.34 mm2 for thrubeam transmitter)
ABS
PMMA
PVC
a or c 24240 V
a or c 20264 V
2000 mA (cos j = 1), 500 mA (cos j = 0.4) for a contact life of 0.5 million operating cycles
at an operating rate of 1 operating cycle per second, at 250 V
250 V
Transmitter: y5 mA
y40 mA (2)
Receiver: y40 mA (2)
20 Hz
y 60 ms
y 25 ms
y 25 ms
Thru-beam and reflex systems
No object present in the beam

Object present in the beam

BN
OG

BN
OG

RD

RD

Relay de-energised

Function
NO

10

Polarised reflex 2

References
5-wire
Transmitter
Weight (kg)

Characteristics

Reflex 2

Diffuse system
No object present in the beam
BN
OG

RD

Relay de-energised

Object present in the beam


BN
OG

RD

Relay energised

(1) For a sensor with a 5 m long cable add L05 to the end of the reference; for a 10 m long cable add L10 to the end of the reference.
Example: sensor XUL M080314 with 5 m cable becomes XUL M080314L05
(2) No-load current consumption at 220 V: y 25 mA

Accessories:
page 5/158

5/146

Curves, dimensions,
schemes

Detection curves
Thru-beam system
of beam
cm

Photo-electric sensors

OsiSense XU Application, conveying series

Compact design
5-wire AC or DC, 1 CO relay output

Reflex system a or c

Diffuse system with background


suppression

of beam
cm

of beam
mm

16 mm

-5

-5

0,2

-10

(1)

-10

(2)
(1) Polarised
(2) Infrared

Sn

0,25 m

0,2

0,25 m

Object 20 x 20 cm
White 90%
2 black 6 %

Excess gain curves (ambient temperature: + 25 C)


Thru-beam system

0,1

-2
-4
-6
-8
-10

2 1

10
8
6
4
2

10

10

Variation of usable sensing distance Su

Reflex system a or c

gain

gain

500

50

100
50

30
25
15
10
7

Diffuse system with background


suppression

gain

10

4
2

A 0,05 0,10

0,1 0,2 0,4 0,8


0,6 1

2 3

0,25

0,35

S (m)

A-B : Object reflection coefficient

0,7 1,5
4 68
10
2
1
With reflector XUZ C80
1 Polarised
2 Infrared

5 8 10 13
4 6 9 D (m)

0,20

20

30

black 6 %
Grey 18 %
White 90 %
Sensing range
Non sensing zone
(Matt surfaces)

D (m)

Dimensions
18
45

(2)

(5)

17
7

45

(6)

39

11

(6)
28
30

(1)

12,5

14

54,5

(5)

4,5

70
28 (3)

80

12

20,6

45

30

20,6
30

(1) Optical axis


(2) Output LED indicator
(3) Front fixing ( 3 screws and inserts included)

(4) 1 elongated hole 4.1 x 10 and 1 x 4.1


(5) 1 elongated hole 3.1 x 10 and 1 x 3.1

Schemes

Wiring schemes (5-wire, a or c)


1 CO output
Transmitter

NC function (object present)


Thru-beam receiver and reflex
BN

BK

BK
RD

BU

BU

NO function (no object present)


Diffuse

OG
BN

RD

10

OG
BN

BU

Accessories:
page 5/158

5/147

References,
characteristics

Photo-electric sensors

OsiSense XU Application
Conveying and access control series

Compact design with teach mode adjustment

Five-wire AC or DC, 1 CO relay output

Three-wire DC, solid-state output

DF524707

Diffuse system (1)


Sensing
distance
(Sn)
m

Function

Output

Reference

Weight
kg

1.5

NO/NC programmable

PNP/NPN

XUY P954S

0.130

NO/NC programmable

PNP/NPN

XUY P952S

0.130

1.5

NO/NC programmable

Relay

XUY P954R

0.150

NO/NC programmable

Relay

XUY P952R

0.150

Function

Output

Reference

NO/NC programmable

PNP/NPN

XUY B954S

0.130

10

NO/NC programmable

PNP/NPN

XUY B952S

0.130

NO/NC programmable

Relay

XUY B954R

0.150

10

NO/NC programmable

Relay

XUY B952R

0.150

DC

AC or DC

Polarised reflex system (2)


Sensing
distance
(Sn)
m

XUY p95pp

Weight
kg

DC

AC or DC

(1) On 300 x 300 mm white paper


(2) With 84 mm reflector

5
6
7

Characteristics

XUY
P954S

Product certifications
Connection
Nominal sensing distance (Sn)
Adjustment using teach (fine or standard mode)
Type of transmission
LED
Degree of protection
Conforming to IEC60529
Ambient air temperature
For storage
For operation
Materials
Immunity to ambient light
Incandescent bulb
Natural light
Indicator lights
Green LED
Red LED
Voltage limits
(including ripple)

c 10...30 V
a/c 20250 V

Current consumption, no-load

8
9
10

Type of output
Switching capacity

b
v
v
v

Applications
Detection of belt breakage
Material handling
Access control

5/148

Lux
Lux

V
mA
VA
mA
A
V
Hz
ms
V

Inactive

XUY
P952S

XUY
P952R

XUY
B954S

XUY
B954R

e, cULus for XUY P954S/952S and XUY B954S/952S


Screw terminals
1.5
4
6

XUY
B952S

ms

XUY
B952R

10

Infrared
Red
IP 65 and IP 67
- 20...+ 80
0...+ 60
Polycarbonate
10 000 at 5 to the optical axis
20 000 at 5 to the optical axis
Output signal
Dirty optics, limit of detection, alignment assistance, time delay active, time function
indicator
p

p
50

50

50

50

2
PNP/NPN Relay
PNP/NPN Relay
PNP/NPN Relay
PNP/NPN Relay
100 with overload and short-circuit protection
3 (max. continuous)
At 100 mA: < 2; at 10 mA: < 1
1000
25
60
25
1000
25
60
25
0.5
20
8
20
0.5
20
8
20
< 1.4

< 1.4

< 1.4

< 1.4

>3

>3

>3

>3

Retriggerable: leading edge and/or trailing edge

Type
Duration of each increment

Adjustment

C
C

PNP/NPN
Relay
PNP/NPN

Voltage drop, closed state


Maximum switching frequency
Delays
Response and recovery
Test input
Active
Output time delay

XUY
P954R

0 to 11 s in 23 adjustment increments of 50 ms, then 0.5 s per press


Using teach mode and/or fine manual adjustment

Photo-electric sensors

Presentation,
dimensions,
schemes

OsiSense XU Application
Conveying and access control series

Compact design with teach mode adjustment

Five-wire AC or DC, 1 CO relay output

Three-wire DC, solid-state output

Presentation

Indicator lights

Rear view

1
2
3
4
5
6
7

t
SET
t

LO-DO

1 - Output signal: Green LED

Controls
5 - Automatic adjustment of threshold
- Access to special functions
- Zero reset of time delay

2 - Dirty optics: Red LED


- Limit of detection: Red LED
- Alignment assistance: flashing red 6 - Sensitivity increase
- NO/NC programming
LED
- Time delay increase
3 - Activation/adjustment of time delay:
Red LED

4 - Action keypad
- Keypad: Action/Locking

7 - Sensitivity decrease
- Inversion of time delay setting: Ondelay, Off-delay
- Time delay decrease

1
2

8 - Access to terminals

3
Note: Both the red and green LEDs flash in the event of a short-circuit on the output (for XUY Pp95pS/XUY Bp95pS versions).

Dimensions

XUY p95pS/XUY p95pR


29

60

(1)
2x4

30

30

80

2xM4

15

(1) Optical axis. .

18

Wiring schemes

XUY p95pS

Output
N

4,5

10,8

5,5

XUY p95pR

0V
Test input

NC C NO

c 10/30 V

Supply

0V

a/c 20/250 V

250 V, 1.5 mm2 terminals.

Application examples

Monitoring for blockages on a baggage conveyor

Monitoring of gluing, fastening or labelling operations

10

5/149

Photo-electric sensors

References

OsiSense XU Application

Design 18
Two-wire AC (1) or DC, solid-state output with adjustable
sensitivity
Diffuse system with adjustable background suppression
Sensing
Function Line of
Connection
Reference
Weight
distance (Sn) m
sight
kg
0.12
NO
Along
Pre-cabled (L = 2 m) (2) XU8M18MA230
0.150
case axis 1/2"-20UNF
XU8M18MA230K
0.075
90 to
Pre-cabled (L = 2 m) (2) XU8M18MA230W
0.150
case axis 1/2"-20UNF
XU8M18MA230WK
0.075
NC
Along
Pre-cabled (L = 2 m) (2) XU8M18MB230
0.150
case axis 1/2"-20UNF
XU8M18MB230K
0.075
90 to
Pre-cabled (L = 2 m) (2) XU8M18MB230W
0.150
case axis 1/2"-20UNF
XU8M18MB230WK
0.075

1
2
XU5M18Mp230W
XU8M18Mp230W

Diffuse system
Sensing
Function Line of Connection
distance (Sn) m
sight
0.40
NO
Along
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF
90 to
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF
NC
Along
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF
90 to
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF

3
4

Weight
kg
XU5M18MA230
0.150
XU5M18MA230K
0.075
XU5M18MA230W
0.150
XU5M18MA230WK
0.075
XU5M18MB230
0.150
XU5M18MB230K
0.075
XU5M18MB230W
0.150
XU5M18MB230WK
0.075

Polarised reflex system (3)


Sensing
Function Line of Connection
distance (Sn) m
sight
2
NO
Along
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF
90 to
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF
NC
Along
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF
90 to
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF

XU9M18Mp230

5
6

Reference

Reference

Weight
kg
XU9M18MA230
0.170
XU9M18MA230K
0.090
XU9M18MA230W
0.170
XU9M18MA230WK
0.090
XU9M18MB230
0.170
XU9M18MB230K
0.095
XU9M18MB230W
0.170
XU9M18MB230WK
0.090

Thru-beam system (4)

XU2M18Mp230

Sensing
Function Line of Connection
distance (Sn) m
sight
15
NO
Along
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF
90 to
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF
NC
Along
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF
90 to
Pre-cabled (L = 2 m) (2)
case axis 1/2"-20UNF

Reference

Weight
kg
XU2M18MA230
0.285
XU2M18MA230K
0.155
XU2M18MA230W
0.285
XU2M18MA230WK
0.155
XU2M18MB230
0.285
XU2M18MB230K
0.155
XU2M18MB230W
0.285
XU2M18MB230WK
0.155

Fixing accessories (5)

8
9

Description
XUZB2003

XUZA118

XUZ2001

XUZA218

XUZ2003

10

5/150

Reference

Weight
kg
0.170

3D fixing kit
for use on M12 rod, for XUp M18 or XUZC50
M12 rod

XUZB2003
XUZ2001

0.050

Support for M12 rod

XUZ2003

0.150

Stainless steel fixing bracket

XUZA118

0.045

Plastic fixing bracket with adjustable ball-joint


XUZA218
(1) These sensors do not incorporate overload or short-circuit protection and therefore,
it is essential to connect a 0.4 A quick-blow fuse in series with the load.
(2) For a 5 m long cable add L5.
Example: XU2M18MA230 becomes XU2M18MA230L5.
(3) 50 x 50 mm reflector XUZC50 included with polarised reflex system.
(4) Comprising both thru-beam transmitter and receiver.
(5) For further information, see page 5/158.

0.035

Photo-electric sensors

Characteristics,
schemes,
curves,
dimensions

OsiSense XU Application

Design 18
Two-wire AC or DC, solid-state output with adjustable
sensitivity

Characteristics
Sensor type
Product certifications
Connection

Connector
Pre-cabled

Sensing distance
nominal Sn / maximum
(excess gain = 2) (excess gain = 1)
Type of transmission
Degree of protection
Storage temperature
Operating temperature
Materials
Vibration resistance
Shock resistance

m
m
m
m

Conforming to IEC60529
C
C
Conforming to IEC60068-2-6
Conforming to IEC60068-2-27

Indicator lights

Output state
Stability

Yellow LED
Red LED (for reflex and thru-beam only)
V
a/c 24240
V
a/c 20264
mA
< 1.5
mA
10200 (1)
V
6
Hz
25
ms
< 300
ms
< 20
ms
< 20
(1) These sensors do not incorporate overload or short-circuit protection and therefore, it is
essential to connect a 0.4 A quick-blow fuse in series with the load.

Rated supply voltage


Voltage limits (including ripple)
Residual current, open state
Switching capacity
Voltage drop, closed state
Maximum switching frequency
Delays
First-up
Response
Recovery

Wiring schemes
Connector

1/2"-20UNF

Pre-cabled

1t
2z
3z

XU2M, XU5M, XU8M, XU9M


XU2M, XU5M, XU8M, XU9MpppppppK
UL, CSA, e

1/2"-20UNF
Length: 2 m

0.12 / 0.12 diffuse with background suppression


0.4 / 0.6 diffuse
2 / 3 polarised reflex
15 / 20 thru-beam
Infrared, except XU9 (red)
IP 67, double insulation i
IP67
- 40+ 70
- 25+ 55
Case: nickel plated brass; Lens: PMMA; Cable: PvR
7 gn, amplitude 1.5 mm (f = 10 to 55 Hz)
30 gn, duration 11 ms

(z) BU
(z) BN

2-wire a or c

(Blue)
(Brown)

Transmitter
/2

/3

2
3
4
5
6

1
t on connector models

1
t on connector models

See connection on page 9/44.

Detection curves
Thru-beam system

Polarised reflex system

Diffuse system

6
4
2

15
10 15
-15

20 m

Diffuse system with adjustable background


suppression

-2 0,2
-4
-6

0,3

3 m

12 cm

60 cm

-1

-1

With reflector XUZC50


Object 10 x 10 cm; 1 White 90%; 2 Grey 18%
Variation of usable sensing distance Su
Potentiometer set at minimum Potentiometer set at maximum
A-B: object reflection coefficient
Black 6%
B
B
Grey 18%
White 90%
Sensing range
Non sensing zone (matt surfaces)

A 0,01

0,07 0,1
0,08

S (m)

A 0,01

0,11 0,15 S (m)


0,12

Dimensions
XUp

Pre-cabled (mm)

b
a

18, line of sight along case axis


18, line of sight 90 to case axis

a
82
97

b
55
55

10

Connector (mm)
a
95
110

b
55
55

5/151

Photo-electric sensors

References,
characteristics

OsiSense XU Application, tertiary sector series


For monitoring flow
AC or DC supply
1 CO relay output

Compact design

1
2
3

System

Reflex

Type of transmission

Infrared

Nominal sensing distance (Sn)

7 m (with 50 x 50 mm reflector)

References
5-wire

XUK1ARCNL2H60 (supplied as kit comprising: sensor, fixing bracket, 50 x 50 mm reflector


and mounting instructions)
0.300

NC function

Weight (kg)

4
5
6
7
8

Characteristics
Product certifications

UL, CSA, e

Ambient air temperature


Vibration resistance

Conforming to IEC60068-2-6

For operation: - 25+ 55 C.


For storage: - 40+ 70 C
7 gn, amplitude 1.5 mm (f = 1055 Hz)

Shock resistance

Conforming to IEC60068-2-27

30 gn, duration 11 ms

Degree of protection

Conforming to IEC60529

IP 65, double insulation i

Connection

Pre-cabled: diameter 6 mm, length 2 m, wire c.s.a.: 5 x 0.34 mm2

Materials

Case: PBT; lenses: PMMA; cable: PVC

Rated supply voltage

a or c 24240 V

Voltage limits

a or c 20264 V

Switching capacity

3A

Maximum voltage on output relay contacts

a 250 V

Power consumption, no-load

2 W (1)

Maximum switching frequency

20 Hz

Delays

First-up:y60 ms; response:y25 ms; recovery:y25 ms

Function table
Output state of relay contact indicator
(illuminated when relay energised)

Function
NC

Reflex system
No object present in the beam

Object present in the beam

BK
WH

BK
WH

GY

Relay energised

(1) No-load current consumption at a 220 V: y 25 mA.

9
10

5/152

GY

Relay de-energised

Curves,
dimensions, schemes

Contents of kit XUK1ARCNL2H60


-

reflex system photo-electric sensor,


fixing bracket,
50 x 50 mm reflector,
mounting instructions.

Photo-electric sensors

OsiSense XU Application, tertiary sector series

For monitoring flow


AC or DC supply
1 CO relay output
Detection curve

Excess gain curve (ambient temperature:


+ 25 C)

Reflex system a or c

Reflex system a or c

of beam cm

Gain
100

50

10

1
1
10 cm 20

50 1 m

5 10 m 20
Sn = 4 m

50 m

With reflector XUZC50

Dimensions

Wiring scheme (5-wire a or c)

XUK 1ARCNL2

XUZ A51

40

BN
GY

BK
WH

6,5

10

6 x 13

60

22

12

12

40

40

BU

34

5 13 15 18 7

6 x 12

48,5
58

Mounting precautions
Rigid fixing

Outdoor mounting

7
8
Fix securely for trouble free detection.

Use protective covers and mount on thermal insulators to avoid frost or condensation forming on
the optical parts.

9
10

5/153

Photo-electric sensors

References,
characteristics

OsiSense XU Application, tertiary sector series


For monitoring flow
AC or DC supply
1 CO relay output

Compact design

1
2
3

System

Reflex

Type of transmission

Infrared

Nominal sensing distance (Sn)

6 m (with 50 x 50 mm reflector)

References
5-wire

XULM06031H60 (supplied as kit comprising: sensor, fixing bracket, 50 x 50 mm reflector


and mounting instructions)
0.300

NC function

Weight (kg)

4
5
6
7
8

Characteristics
Product certifications

Ambient air temperature


Vibration resistance

Conforming to IEC60068-2-6

For operation: - 25+ 55 C.


For storage: - 40+ 70 C
7 gn, amplitude 2 mm (f = 1055 Hz)

Shock resistance

Conforming to IEC60068-2-27

20 gn, duration 11 ms

Degree of protection

Conforming to IEC60529

IP 67 (Indoor use)

Connection

Pre-cabled: diameter 6 mm, length 2 m, wire c.s.a.: 5 x 0.34 mm2

Materials

Case: ABS; lenses: PMMA; cable: PVC

Rated supply voltage

a or c 24240 V

Voltage limits

a or c 20264 V

Switching capacity
Maximum voltage on output relay contacts

2000 mA (cos j =1), 500 mA (cos j = 0.4) for a contact life of 0.5 million operating cycles
at an operating rate of 1 operating cycle per second, at 250 V
a 250 V

Current consumption, no-load

y 40 mA (1)

Maximum switching frequency

20 Hz

Delays

First-up:y60 ms; response:y25 ms; recovery:y25 ms

Function table
Output state of relay contact indicator
(illuminated when relay energised)

Function
NC

Reflex system
No object present in the beam

Object present in the beam

BN
OG

BN
OG

RD

Relay energised

(1) No-load current consumption at a 220 V: y 25 mA.

9
10
Accessories:
page 5/158

5/154

RD

Relay de-energised

Photo-electric sensors

Curves,
dimensions,
schemes

OsiSense XU Application, tertiary sector series

For monitoring flow


AC or DC supply
1 CO relay output

Contents of kit XULM06031H60


-

reflex system photo-electric sensor,


fixing bracket,
50 x 50 mm reflector,
mounting instructions.

Detection curve

Excess gain curve (ambient temperature: + 25

Reflex system a or c

Reflex system a or c

10
5
-5

0,2

-10

2
With reflector XUZC50

3
Dimensions
Bracket fixing

18

(1)

45

10
11

10 O

(3)

18
7

10 O

14

10

12,5

20,6

39

45

10O

30

5
6

12

30

28

(4)
54,5

28 (2)

80

70

(4)

(3)

10

4,5

45

20,6
30
(1) LED
(2) Front fixing ( 3 screws and inserts included).
(3) 1 elongated hole 4.1 x 10 and 1 x 4.1
(4) 1 elongated hole 3.1 x 10 and 1 x 3.1

Wiring scheme (5-wire a or c)


1 CO output
NC function(object present)

Mounting precautions
Rigid fixing

Outdoor mounting

BK
OG
RD
BN
BU

Fix securely for trouble free


detection.

Use protective covers and mount on thermal insulators to


avoid frost or condensation forming on the optical parts.

Accessories:
page 5/158

5/155

10

Photo-electric sensors

References,
characteristics

OsiSense XU Application, tertiary sector series


With integral buzzer
AC or DC supply
1 NO relay output

Compact design

1
2
3

System

Reflex

Type of transmission

Infrared

Nominal sensing distance (Sn)

6 m (with 80 mm reflector)

Cable gland

9P, mounted in base

References

NO function

XUJB06031H60 (supplied as kit comprising: sensor, fixing bracket, 80 mm reflector and


mounting instructions)
0.330

Weight (kg)

Characteristics

5
6
7
8

Product certifications

Ambient air temperature


Vibration resistance

Conforming to IEC60068-2-6

For operation: - 25+ 55 C.


For storage: - 40+ 70 C
7 gn, amplitude 1.5 mm (f = 1055 Hz)

Shock resistance

Conforming to IEC60068-2-27

30 gn, duration 11 ms

Degree of protection

Conforming to IEC60529

IP 40, double insulation i

Connection

Screw terminals, maximum capacity: 1 x 1.5 mm2

Materials

Case: PEI (1)

Rated supply voltage

a 24240 V or c 2448 V

Voltage limits

a 20264 V or c 2060 V (including ripple)

Switching capacity
Maximum voltage on output relay contacts

2000 mA (cos j =1), 500 mA (cos j = 0.4) for a contact life of 1 million operating cycles at
an operating rate of 1 operating cycle per second, at 250 V
a 250 V or c 30 V

Current consumption, no-load

y 30 mA

Maximum switching frequency

20 Hz

Delays

First-up: y 60 ms; response: y 25 ms; recovery: y 25 ms

Time delay

Adjustable from 0.3 to 3 seconds

Function table

Output state of relay contacts indicator:


yellow LED
(illuminated when relay energised)

Function

Reflex system
No object present in the beam

Object present in the beam

NO
4

Relay deenergised

yellow

Relay
energised

yellow

(1) PEI: high quality synthetic resin providing excellent withstand to mechanical shocks, vibration and the effects of external agents frequently encountered in
industry: alcohol, salts, petroleum, oils, greases, washing agents (diluted sodium carbonate 4%, nitric acid 2%), formaldehyde vapour, splashing lactic acid, etc.

10

5/156

Photo-electric sensors

Curves,
dimensions,
schemes

OsiSense XU Application, tertiary sector series

With integral buzzer


AC or DC supply
1 NO relay output

Detection curve

Contents of kit XUJB06031H60

Reflex system
-

6
4
2
0
-2
-4
-6

reflex system photo-electric sensor,


fixing bracket,
80 mm reflector,
mounting instructions.

Excess gain curve (ambient temperature: + 25 C)


Infrared reflex system

1000
500
100
50
10
5
1

4
0,1

0,2

0,4

10
D (m)

With reflector XUZC80

Dimensions
66

2,6

Bracket fixing

27,2

(4)

12,8

(6)

12 (2)

85
62,5

16

96

25

12 14

(7)

13

25

30 (5)

10 10 25

25

24

(8)

6,5

Face view

62,5

XUJB06031H60

10
28

(1)

14 (3)

12,7

12,8

55,2

57

(1) 9P cable gland.


(2) 2 elongated holes 6.5 x 10.
(3) 1 elongated hole 6.5 x 24.
(4) 8 elongated holes 4.2 x 10.
(5) Front fixing ( 4 screws and inserts included).
(6) Yellow LED.
Wiring schemes (a or c)
NO function
Object present
/+
2
4
5
1

(7) 2 elongated holes 6.5 x 16.5.


(8) 1 elongated hole 6.5 x 30.5.

8
Terminal connections
1 NO relay output
1
2
3
4
5

A1 (
A2 (

/)
/+)

a 250 V, 100 VA max.


c 30 V, 2 A max.

10

5/157

References

Photo-electric sensors

OsiSense XU
Accessories

3D fixing kit (1)


Description

1
XUZB2003

XUZM2003

XUZK2003

2
XUZX2003

XUZM2004

XUZK2004

3
XUZ 2001

For use with


sensor type
XUB or XUZC50
Ball-joint mounted fixing
bracket for mounting on M12 XUM 0 or XUZC50
rod
XUK or XUZC50
XUX or XUZC50
Ball-joint mounted fixing
XUM 0
bracket with protective
XUK
cover for mounting on M12
XUX
rod
Support for M12 rod

M12 rod

(adjustment possible over


complete height)
(1) To obtain a 3D fixing kit, order:
- rod support XUZ2003
- M12 rod XUZ2001
- ball-joint mounted fixing bracket XUZp200p

0.150
0.050

XUZ 200

XUZ2001

3D fixing kit example

Fixing accessories

Description

For use with


sensor type
XUB

Reference

XUM
XUK
XUX
XUL
XUJ
XUJ B
XUp ( 18 mm)

XUZ A50
XUZ A51
XUZX2000
XULZ41
XUZA41
XUZA49
XUZA218

0.025
0.050
0.065
0.050
0.050
0.120
0.035

Precision fixing bracket


with micrometric adjustment

XU2 ( 18 mm)
with laser transmission

XUZ A318

0.170

Plastic fixing clamps


with locking screw

Set of 2 plastic nuts

XSAZ108
XSZB108
XUp ( 18 mm) With lug
XSAZ118
With indexing pin XSZB118
With 24.1 mm ctrs. XUZB2005
Glass fibre optics XUFS0810
XSAZ145
Fibre optics XUFS2510
XSAZ155
Fibre optics XUFS0210
XSAZ185
XUp ( 18 mm)
XSZE218

Set of 2 metal nuts

XUp ( 18 mm)

XSZE118

0.015

Set of 2 stainless steel nuts XUp ( 18 mm)

XSZE318

0.015

Stainless steel fixing


bracket
Metal fixing brackets
XUZA118

XUZA50

XUZA51

7
Plastic fixing bracket
with adjustable ball-joint

10

XUZ2003
XUZ2001

XUZ 2003

XUZ2003

XUZB2003
XUZ M2003
XUZK2003
XUZX2003
XUZ M2004
XUZK2004
XUZX2004

Weight
kg
0.170
0.140
0.170
0.220
0.155
0.270
0.420

XUZX2004

Reference

XUZX2000

XUZA49

XSAZ1pp

5/158

XULZ41

XUZA218

XSZB1pp

XUZA41

XUZA318

XUZB2005

XUZA118

XUA ( 8 mm)

Weight
kg
0.045

0.007
0.006
0.020
0.010
0.007
0.005
0.005
0.005
0.004

References (continued)

Photo-electric sensors

OsiSense XU

Accessories

Reflectors
Description

Dimensions
(mm)
16
21
31
39
80
50 x 50

Length
(m)

XUZC16
XUZC21
XUZC31
XUZC39
XUZC80
XUZC50

Weight
kg
0.002
0.002
0.005
0.008
0.029
0.020

24 x 21

XUZC24

0.007

100 x 100

XUZC100

0.062

Width: 22
Thickness: 0.4

1
5

XUZB01
XUZB05

0.015
0.075

Reflective adhesive
Width: 22
tape (1)
Thickness: 0.4
(specifically for polarised reflex
systems)

1
5

XUZB11
XUZB15

0.020
0.085

Standard reflectors

XUZCpp

XUZC100

XUZC50

XUZB0p

XUZC24

Universal reflector
(without blind zone)
Reflector for short sensing
distances
Reflector for long sensing
distances
Standard reflective adhesive
tape (1)

Reference

Protective covers

Potentiometer
protective cover

For use with

Reference

Sensors XUX and XUJ


Reflectors XUZ C80
or XUZ C24
Sensors XUJ

XUZD25
XUZD15

Weight
kg
0.920
0.270

XUJZ01

0.015

XUZD15

XUJZ01

XURZ01

Cabling accessories
Description

Reference

XUZX2001
XUZX2002

Weight
kg
0.050
0.050

6
7

Lenses

XURZ02

Adaptor, ISO 16 - 1/2" NPT


Adaptor, ISO 16 - ISO 20

XUZX2001

Protective covers
Description

XUZD25

Description

For use with

Reference

Lens for spot


enlargement

Sensors XUR

XURZ01

Weight
kg
0.010

Lens accessory for


spot reduction

Sensors XUR

XURZ02

0.015

Spare parts
Description

For use
with
Plastic end adaptor for
Amplifiers XUD
connecting 1 mm fibre optics A

Sold in
lots of
2

Unit
reference
XUFZ08

Weight
kg
0.002

XUFZ08

Protection fuses
Description
Cartridge fuse
5 x 20
0.4 A quick-blow
Fuse terminal block

For use
with
Sensors without
short-circuit
protection
Cartridge fuses
XUZE0p

Sold in
lots of
10

Unit
reference
XUZ E04

50

AB1FU10135U

Weight
kg
0.001
0.040

(1) Suitable for use at maximum ambient temperature of + 50 C.

5/159

10

Dimensions

Photo-electric sensors

OsiSense XU
Accessories

XUZB2003

36

Support for M12 rod

22,9
5,7

45

49

13,5

25

12,5
25

M3

XUZK2003

Ball-joint mounted fixing bracket with protective cover for XUK (1)

40,5

33

40

60

33
59,5
40

20

25,8

40

20

56,5

30,6

40

20

7
XUZX2003

XUZX2004

Ball-joint mounted fixing bracket for XUX (1) or XUZ C50

Ball-joint mounted fixing bracket with protective cover for XUX (1)

73

23,1

36

40,5

41,5

52
99

73

73

33

60

38

52,5

100

M4

20

27

17,5

28

45

60
28

63

XUZK2004

Ball-joint mounted fixing bracket for XUK (1) or XUZ C50

M5

4,5

10

51

23,5
50

(1) Accessory fixing screws included.

5/160

18
49,5

36

23

21
13

19,5

21

M3

40,5

38

33

42

19

XUZ M2004
Ball-joint mounted fixing bracket with protective cover for XUM (1)

29
M4

M12

40

50

XUZ M2003
Ball-joint mounted fixing bracket for XUM (1) or XUZ C50

1,9
53

19

76,5

12

19

132

67

33

40

40

55

M4

XUZ2003

M12 rod

126

XUZ2001

Ball-joint mounted fixing bracket for XUB or XUZ C50

Mounting

Photo-electric sensors

OsiSense XU

Accessories

XUZB2003 + XUZ2001 + XUZ2003


3D fixing kit for XUB or reflector XUZC50

XUZ2001 + XUZ2003
M12 rod + rod support

1
2
3

XUZM2003 + XUZ 2001


3D fixing kit for XUM or reflector XUZC50

XUZM2004 + XUZ2001
3D fixing kit with protective cover for XUM

4
5
XUZK2003 + XUZ2001
3D fixing kit for XUK or reflector XUZC50

XUZK2004 + XUZ2001 + XUZ2003


3D fixing kit with protective cover for XUK

6
7
Mounting example

XUZX2003 + XUZ2001
3D fixing kit for XUX or reflector XUZC50

XUZX2004 + XUZ2001
3D fixing kit with protective cover for XUX

9
10

5/161

Dimensions

Photo-electric sensors

OsiSense XU
Accessories

XUZ A50

10

50

45

10

4,5

2,5

Fixing bracket for XUM (2)

25

5 25,5

35

XUZA218
Fixing bracket with adjustable ball-joint
for XUp ( 18)

15

55

6,5

15

18

3,2
8,3

20

XUZ A51

8,2 x 3,2

4
27

XUZX2000
Fixing bracket for XUX (2)

58

Fixing bracket for XUK (2)


40

7,5

= =

6,5

6,5

10

16,5

1
=

3x4

8 24 8

19,5

28

41

XUZA118
Fixing bracket for XUB

64

3
R

10

30

52
12

12

16,5

64
6 x 12

5 13 15 18 7
48,5

12,8

XUZ A318

6,5
120,1

14 7
24

XSZB108, XSZB118

Fixing bracket with micrometric adjustment for XU2 ( 18) with


laser transmission

Fixing clamps for XUA and XUp ( 18)

9,5
39

=
59

a1
a

22,3 8

15

44

3,5

(1)

b1

=
34

55

64

35
45

=
30

38,3

b2

6 x 13

22

58

18

20
28

10

60

34

40

40

5,5

9,5

XSAZ1pp
Fixing clamps for XUA, XUp ( 18), XUF

2,5

Fixing clamps with 24.1 mm centres for XUp ( 18)

d1

d2

20

13,2

9
16

==
c

30,7
=

G1

10
(2) Accessory fixing screws included.

5/162

d3
= =
G
a

24,1
3

8
18

f
b

XUZB2005

b2
7.5
11.5

8 24 8

b1
12.8
20.1

b1

9,5

6,5

XCZ a
a1
b
B108 21.1 14.5 14.2
B118 26
15.7 22.3
(1) 2 elongated holes 4 x 8.

XSA
Z108
Z118
Z145
Z155
Z185

a
23.5
41
23.5
23.5
23.5

b
14.2
30
14.2
14.2
14.2

b1
16.7
33
16.7
16.7
16.7

c
10
17
10
10
10

d
8
18
8
8
8

d1
8.1
18.1
4.7
5.7
8.6

d2
2
3.9
2
2
2

d3
4
6
4
4
4

f
10.5
24
10.5
10.5
10.5

G
16
30
16
16
16

G1
5
7
5
5
5

Dimensions (continued)

Photo-electric sensors

OsiSense XU

Accessories

XUZD15

XUZD25

Protective cover for XUZ C80 or XUZ C24

Protective cover for XUX or XUJ

149

133,5

22

73
91
83,4
128 135

XUZCpp

16

80

16

66

72

88

(1)

101,5

16

48

44

=
44

XUZC50

XUZM2003 + XUZ2001 + XUZ2003


+ XUZ C50
Mounting example

35
4xR5

21
25.5
35
46

c
5.5
6
7.5
6.5

d
17
20.5
30.5
37

60

47

51

XUZ
C16
C21
C31
C39

69

d
c

5
3,5 (1)
8

51,5

(1) 2 elongated holes 4.5 x 8

XUZC24

XUZC100

XUZX2001
1/2" NPT

7,5

24
=

9,5

96

100

33

21

45

27

M16

96

11,3

11

32

100

7
8

29

XUZC80

XUZX2002
M20

26

M16

4,5

11,3

11

31

10
7,5

5/163

Photo-electric sensors

Curves

OsiSense XU General purpose

XUB0 Multimode function with line of sight along case axis

Sensing distance and operating margin


Background suppression mode

0,010,12 m max.

12

1 cm

17 cm

8 cm 10 cm

1 cm

Without accessory

Background distance(1)

17 cm

13,5 cm
10

5 cm
5 cm
8 10 cm 12 cm
Maximum distance of object to be detected (1)

Background

Example: teaching against a background located at


13.5 cm enables detection of an object at 1 to
10cm.

a: with background teaching at maximum


recommended distance.
b: with background teaching at minimum
recommended distance.

(1) From white 90% to black 6%.

Diffuse mode
00,4 m max.

Gain

(1)

500
0

13

30

40 cm

(2)
0

Without accessory

13

18 cm

(3)
0,3 cm 8

5
6

100
50

20
10
5

2
3

EG = 2

11 cm

1
0,1 cm

(1) White 90%. (2) Grey 18%. (3) Black 6%.


Object teaching zone

0,5 1

10
50 100 cm
Sn = 30 cm Distance

1 White object
2 Grey object
3 Black object

In diffuse mode, teaching of the position of the object to be detected, located between 0 and 12 cm,
automatically configures the product to background suppression mode. This provides a constant usable
sensing distance, whatever the colour of the object.

Polarised reflex mode


Gain
100

XUZ C50

0,0035 m max.

3 mm

2m

50

3m

XUZ C24

With reflector

10

3 mm 0,9 m 1,3 m

XUZ C100

1
2

EG = 2

5 mm

4m

5m

0,1 m

0,5

Sn = 2 m

10 m
Distance

1 With reflector XUZC50


2 With reflector XUZC24
3 With reflector XUZC100

8
Thru-beam mode

Gain
1000
500

020 m max.
0

15

20 m
100
50

With thru-beam accessory

10
5
EG = 2
1

10
Nominal sensing distance. EG 2.
Maximum sensing distance. The maximum sensing distances indicated are average values.
EG: Excess gain, operating margin.

5/164

1m

10
50 m
Sn = 15 m Distance

Photo-electric sensors

Curves

OsiSense XU General purpose

XUB0 Multimode function with line of sight 90 to


case axis

Sensing distance and operating margin

15 cm
13,5 cm

0,010,11 m max.

Background distance (1)

Background suppression mode

11

0 cm

15 cm

b
8 cm

0 cm

10 cm

7,5

Without accessory

0 cm
0 cm
6
10 11 cm
Maximum distance of object to be detected (1)

Background

Example: teaching against a background located at


13.5 cm enables detection of an object at 0 to
10cm.
(1) From white 90% to black 6%.

a: with background teaching at maximum


recommended distance.
b: with background teaching at minimum
recommended distance.

Diffuse mode
00,3 m max.

Gain

(1)

500
0

10

10

20

30 cm

100
50

(2)

20
10
5

14 cm

(3)

Without accessory

EG = 2

0,3 cm 6,5 8 cm

(1) White 90%. (2) Grey 18%. (3) Black 6%.


Object teaching zone

1
2

1 cm

10

50 100 cm
Sn = 20 cm Distance

1 White object
2 Grey object
3 Black object

In diffuse mode, teaching of the position of the object to be detected, located between 0 and 11 cm,
automatically configures the product to background suppression mode. This provides a constant usable
sensing distance, whatever the colour of the object.

Polarised reflex mode


XUZ C50

04 m max.

Gain
100

50

1,5 m 2 m

0 cm

XUZ C24
3 cm

With reflector
3m

4m

EG = 2

XUZ C100
0 cm

10

0,8 m 1,2 m

0,1 m

0,5

1
Sn = 1,5 m

10 m
Distance

1 With reflector XUZC50


2 With reflector XUZC24
3 With reflector XUZC100

Thru-beam mode
014 m max.
0

10

14 m

Gain
1000
500

100
50

With thru-beam accessory

10
5
EG = 2

1m

5
Sn = 10 m

50 m
Distance

Nominal sensing distance. EG 2.


Maximum sensing distance. The maximum sensing distances indicated are average values.
EG: Excess gain, operating margin.

5/165

10

Photo-electric sensors

Curves

OsiSense XU, general purpose, single mode


function

XUBppppp with line of sight along or at 90 to case axis


Sensing distance and operating margin

Diffuse sensor XUB4ppppppp with line of sight along case axis


0,0010,15 m max.

Gain
100

(1)
10

0,1 cm

15 cm

50

1
(2)

7 cm

0,6 cm

3 4 cm

Diffuse sensor XUB4ppppppp with line of sight 90 to case axis

0 cm

10

15 cm

7 cm

(3)

50 cm
Sn = 10 cm Distance

50

EG = 2

0,3 cm 2

4 cm

0,1 cm

0,5

5
50 cm
Sn = 10 cm Distance

1 White object
2 Grey object
3 Black object

(1) White 90%. (2) Grey 18%. (3) Black 6%.

Diffuse sensor XUB5ppppppp with line of sight along or at 90 to case axis


(1)

0,0010,8 m max.

Gain

(4)

60

0,1 cm

80 cm

(2)

50
0,2 cm

25

38 cm

10
5

(3)
a

(4)

EG = 2
1
0,1 cm

0,5 1

0,4 cm 15 21 cm

(1) White 90%. (2) Grey 18%. (3) Black 6%.


(4) No detection.

Nominal sensing distance. EG 2.


Maximum sensing distance. The maximum sensing distances indicated are average values.
EG: Excess gain, operating margin.
a: Potentiometer set at maximum.
b: Potentiometer set at minimum.

10

5/166

(4)

500
100

10

0,1 cm

(2)

0,5

Gain
100

(1)

0,1 cm

1 White object
2 Grey object
3 Black object

(1) White 90%. (2) Grey 18%. (3) Black 6%.

00,15 m max.

EG = 2

(3)

10

0,3 cm

1 White object
2 Grey object
3 Black object

10

50 100 cm
Sn = 60 cm
Distance

Photo-electric sensors

Curves

OsiSense XU, general purpose, single mode


function

XUBppppp with line of sight along or at 90 to case axis


Sensing distance and operating margin

Polarised reflex sensor XUB9ppppppp with line of sight along or at 90 to case axis
XUZ C50

0,0035 m max.

5 mm

Gain
100

2m

50

3m

XUZ C24

With reflector

3 mm

1 m 1,5 m

EG = 2

XUZ C100

5 mm

4m

5m

Reflex sensor XUB1ppppppp with line of sight along or at 90 to case axis


XUZ C50

0,0039 m max.

10

0,1 m

0,5

10 m
5
Sn = 2 m Distance

1 With reflector XUZC50


2 With reflector XUZC24
3 With reflector XUZC100
Gain

500

5 mm

4m

5,5 m

With reflector
3 mm

5
EG = 2

XUZ C100
5 mm

10

2 m 2,5 m

100
50

XUZ C24

7m

9m

Thru-beam sensor XUB2ppppppp with line of sight along or at 90 to case axis

0,1 m

0,5

5
Sn = 4 m

10 m
Distance

1 With reflector XUZC50


2 With reflector XUZC24
3 With reflector XUZC100

Gain
1000

020 m max.

500

0m

15

20 m
100
50
10

5
EG = 2

With thru-beam accessory

1m

10
50 m
Sn = 15 m Distance

Nominal sensing distance. EG 2.


Maximum sensing distance. The maximum sensing distances indicated are average values.

EG: Excess gain, operating margin.

9
10

5/167

Photo-electric sensors

Curves

OsiSense XU, general purpose


XUM0 multimode function

Sensing distance and operating margin


Background suppression mode

00,11 m max.

15 cm

11 cm

1 cm

1 cm

Without accessory

5 cm 6 cm

cm
15

10

Background

3
a: with background teaching at maximum
recommended distance.
b: with background teaching at minimum
recommended distance.

Background distance (1)

4
5
7
11 cm
Maximum distance of object to be detected (1)

Example: teaching against a background located at


10 cm enables detection of an object at 1 to 7 cm.
(1) From white 90% to black 6%.

Diffuse mode
Gain
100

(1)

00,55 m max.

10

40

50

55 cm

50

(2)

18

25 cm

Without accessory

10 15 cm

EG = 2

(1) White 90%. (2) Grey 18%. (3) Black 6%.

10

(3)

Object teaching zone

1
1 cm

1 White object
2 Grey object
3 Black object

10

50 100 cm
Sn = 40 cm Distance

In diffuse mode, teaching of the position of the object to be detected, located between 0 and 10 cm,
automatically configures the product to background suppression mode. This provides a constant usable
sensing distance, whatever the colour of the object.

Nominal sensing distance. EG u 2.


Maximum sensing distance. The maximum sensing distances indicated are average values.
EG: Excess gain, operating margin.

8
9
10

5/168

Photo-electric sensors

Curves (continued)

OsiSense XU, general purpose


XUM0 multimode function

Sensing distance and operating margin (continued)


Polarised reflex mode

0,026,5 m max.

2 cm

Gain

XUZ C50

50

3m

4m

XUZ C24
10

1 cm

1,4 m 1,6 m

XUZ C100

With reflector

EG = 2

2 cm

4,8 m

6,5 m

1 cm

5 0,1 m

0,5 1 m

5 m 10 m
Sn = 3 m Distance

1 With reflector XUZC50


2 With reflector XUZC24
3 With reflector XUZC100

Thru-beam mode

Gain
1000

014 m
max.

10

14 m

500

100

50

With thru-beam accessory

10
5
EG = 2

1
1m

Sn = 10 m

20 m
Distance

Nominal sensing distance. EG u 2.


Maximum sensing distance. The maximum sensing distances indicated are average values.
EG: Excess gain, operating margin.

7
8
9
10

5/169

Curves

50

20

Photo-electric sensors

10

2
10 cm

50 1 m

OsiSense XU, general purpose

5 10 15 20
Sn = 11 m

40 m

Multimode function
XUK 0

Sensing distance and operating margin


Background suppression mode

028 cm max.

28

0 cm

38 cm

b
0 cm

cm
38
30
20
10
0

Without accessory

8 cm 10 cm

Background distance (1)

Background
a: with background teaching at maximum
recommended distance.
b: with background teaching at minimum
recommended distance.

8 10
20 22
28 cm
Maximum distance of object to be detected (1)

Example: teaching against a background located at


30 cm enables detection of an object at 0 to 22 cm.
(1) From white 90% to black 6%.

Diffuse mode
Gain

01,2 m max.

(1)

20
0

0,8

1m

1,2 m

(2)
0

0,4

0,55 m

1,5 cm

5
3
2
1

0,5
0,3
0,2

(3)
Without accessory

10

0,3 m

0,1
1 cm

(1) White 90%. (2) Grey 18%. (3) Black 6%.


Object teaching zone

2
3
5

10

50

100 200 cm
Distance

1 White object
2 Grey object
3 Black object

In diffuse mode, teaching of the position of the object to be detected, located between 0 and 0.3 m,
automatically configures the product to background suppression mode. This provides a constant usable
sensing distance, whatever the colour of the object.

Polarised reflex mode


Gain
50

XUZ C50

0,0211 m max.

2 cm

4m

5,7 m

20

XUZ C24

10

0,5 cm 2 m
1,7

XUZ C100
9m

2 cm

11 m

1
1
10 cm 30 50 0,1 m

5 1m 2
5 10 20 m
Sn = 4 m

1 With reflector XUZC50


2 With reflector XUZC24
3 With reflector XUZC100

Thru-beam mode

045 m
max.

EG = 2

With reflector

Gain
1000
500

30 m

45 m
100
50
10
5

With thru-beam accessory

10

Nominal sensing distance. EG u 2.


Maximum sensing distance. The maximum sensing distances indicated are average values.
EG: Excess gain, operating margin.

5/170

EG = 2

10 m

50
Sn = 30 m

100 m

Photo-electric sensors

Curves

OsiSense XU, general purpose

Multimode function
XUKpAppp

Sensing distance and operating margin


Diffuse sensor XUK5Appp

01,5 m max.

(4)
0

1m

1,5 m

(2)
a

EG = 2

(4)
0

0,5 m

1
0,1

(4)
0

Polarised reflex sensor XUK9Appp

5 6

1 White object
2 Grey object
3 Black object

c
d

EG = 2

5 cm 1,4 2

1
10 cm 20 30 50

c
d
5 cm

8m

10 m

13 m

Reflex sensor XUK1Appp

1m

10
Sn = 5 m

20 m

Gain

XUZ C50

100

50

7 m 9 11 m 15 m

XUZ C24

10

d
3 cm

1 With reflector XUZ C50


2 With reflector XUZ C24
3 With reflector XUZ C100

5 cm

3m

XUZ C100

EG = 2

3 4 5,5 m

XUZ C100

1
10 cm 20

c
d
5 cm

15 m

20 m
19 m

25 m

Thru-beam sensor XUK2Appp


045 m
max.

2m

Sn = 1 m

7,5 m

XUZ C24

With reflector

0,5

10

10 cm

0,0525 m max.

0,3

Gain
20

XUZ C50
c
d

With reflector

0,2

0,3 m 0,5 m

(1) White 90%. (2) Grey 18%. (3) Black 6%.


(4) No detection.

0,1013 m max.

0,8 m

(3)
a
b

Without accessory

Gain
5

(1)
a

50 1 m

5 10 m 20
Sn = 4 m

50 m

1 With reflector XUZ C50


2 With reflector XUZ C24
3 With reflector XUZ C100

Gain
1000

c
d
0

20 m

30 m

45 m

100
50

10
5
EG = 2

With thru-beam accessory

1
10 cm

50 1 m

10 m
50 100 m
Sn = 30 m

10

Nominal sensing distance. EG u 2.


Maximum sensing distance. The maximum sensing distances indicated are average values.
a: Potentiometer set at maximum.
b: Potentiometer set at minimum.
EG: Excess gain, operating margin.

c: XUKpAPpppp or XUKpANpppp, DC solid-state output version.


d: XUKpARpppp, AC/DC relay output version.

5/171

Curves

50

20

Photo-electric sensors

10

OsiSense XU, general purpose


Multimode function

XUX 0
10 cm

50 1 m

5 10 15 20
Sn = 11 m

40 m

Sensing distance and operating margin


Background suppression mode

1,5 m

0,011,3 m max.

1,3

0 cm

1,5 m

38 cm 40 cm

6 cm

Without accessory

Background distance (1)

1m
50
40
20

10 cm
10 cm
20
38
90 1 m 1,3 m
Maximum distance of object to be detected (1)

Background

Example: teaching against a background located at


1 m enables detection of an object at 0 to 90 cm.

a: with background teaching at maximum


recommended distance.
b: with background teaching at minimum
recommended distance.

(1) From white 90% to black 6%.

Diffuse mode
Gain
1000

(1)

03 m max.

1,3

3m

100

(2)
0

1 1,3 m
10

Without accessory

(3)
1,5 cm 0,6 0,8 m

1
1 cm

(1) White 90%. (2) Grey 18%. (3) Black 6%.


Object teaching zone

10 cm

1m

10 m
Distance

1 White object
2 Grey object
3 Black object

In diffuse mode, teaching of the position of the object to be detected, located between 0 and 1.3 m,
automatically configures the product to background suppression mode. This provides a constant usable
sensing distance, whatever the colour of the object.

Polarised reflex mode


XUZ C50

0,0535 m max.

Gain

XUZ C24

20

10

3 cm

5m 6m

XUZ C100

EG = 2

With reflector
5 cm

50

11 m 15 m

5 cm

25 m

35 m

10 cm

50 1 m

5 10 15 20
Sn = 11 m

40 m

1 With reflector XUZC50


2 With reflector XUZC24
3 With reflector XUZC100

Thru-beam mode

Gain

10 000

060 m max.

40

60 m

1000

100

With thru-beam accessory

10

10
5
EG = 2
5 cm 10

Nominal sensing distance. EG 2.


Maximum sensing distance. The maximum sensing distances indicated are average values.
EG: Excess gain, operating margin.

5/172

50

1m

5 10

100 m
Sn = 40 m

Photo-electric sensors

Curves

OsiSense XU, general purpose


Single mode function

XUXpAppp
Sensing distance and operating margin
Diffuse sensor XUX5Apppppp

Gain
200

(1)
a

03 m max.

100

b
18 cm

2,1 m

55 cm

3m

(4)

1 m 1,3 m

EG = 2

(3)
a

3 cm 5

(4)
0

0,6 m 0,8 m

(1) White 90%. (2) Grey 18%. (3) Black 6%.


(4) No detection.

Polarised reflex sensor XUX9Apppppp

5 cm
1,2

3,7 4,8

11 m

50

3 5m
Sn = 2,1 m

1 White object
2 Grey object
3 Black object

4,4 5,7 m
3 cm
1,1 1,9 2,5 m

a
b

EG = 2

XUZ C100

a
b

7,5 m 10 m

20 m

26 m

Reflex sensor XUX1Apppppp

50 cm 1 m

5m

15 20 30 m
Sn = 11 m

1 With reflector XUZC50


2 With reflector XUZC24
3 With reflector XUZC100
Gain
50

XUZ C50
a
b

1,4 5,1 7 m

14 m

20 m

10

3 cm
0,45 2,1 3 m 5,2

EG = 2

7,1 m

XUZ C100
a
b

0,2

5 cm
60 cm

12 m

25 m

35 m

Thru-beam sensor XUX2Apppppp

060 m max.

0,5 1 m

5 7 10
20
Sn = 15 m

40 m

1 With reflector XUZC50


2 With reflector XUZC24
3 With reflector XUZC100

Gain
10 000

5
6

20

5 cm

XUZ C24

With reflector

1m

10

15 m

XUZ C24

5 cm
65 cm

10

Gain
30
20

XUZ C50
a

0,0535 m max.

10

With reflector

50

(2)
a

0,0530 m max.

b
0

3,6 5,5 m

40 m

60 m

1000

100
50

With thru-beam accessory

10
5
EG = 2
1
70 cm 1 m

10

40 60 100 m

10

Nominal sensing distance. EG 2.


Maximum sensing distance. The maximum sensing distances indicated are average values.
a: Potentiometer set at maximum.
b: Potentiometer set at minimum.
EG: Excess gain, operating margin.

5/173

Substitution table

Sensors with the closest


functionalities

Old sensor

New OsiSense XU sensor

Diameter 18 mm sensors
XU1B18NP340

XUB0ANSNL2+XUZC50 (1)

XU1B18NP340D

XUB0ANSNM12+XUZC50 (1)

XU1B18PP340

XUB0APSNL2+XUZC50 (1)

XU1B18PP340D

XUB0APSNM12+XUZC50 (1)

XU1N18NP340

XUB1BNANL2+XUZC50 (2)
XUB1BNBNL2+XUZC50 (3)

XU1N18NP340D

XUB1BNANM12+XUZC50 (2)
XUB1BNBNM12+XUZC50 (3)

XU1N18NP340L5

Photo-electric sensors

Old sensor

New OsiSense XU sensor

Old sensor

New OsiSense XU sensor

XU2B18NP340D

XUB0ANSNM12
+XUB0AKSNM12T

XU2N18PP340WD

XUB2BPAWM12R
+XUB2BKAWM12T (4)

XU2B18PP340

XUB0APSNL2
+XUB0AKSNL2T

XU2B18PP340D

XUB0APSNM12
+XUB0AKSNM12T

XU2M18NP340

XUB0BNSNL2
+XUB0BKSNL2T (6)

XU2M18NP340D

XUB0BNSNM12
+XUB0BKSNM12T (6)

XU2M18NP340WD

XUB2BNAWM12R
+XUB2BKSWM12T (2) (6)

XUB1BNANL5+XUZC50 (2)

XUB2BNBWM12R
+XUB2BKSWM12T (3) (6)

XUB1BNBNL5+XUZC50 (3)
XU1N18NP340W

XUB1BNAWL2+XUZC50 (2)

XU2M18PP340

XUB0BPSNL2
+XUB0BKSNL2T (6)

XU2M18PP340D

XUB0BPSNM12
+XUB0BKSNM12T (6)

XU2M18PP340L10

XUB0BPSNM12
+XUB0BKSNM12T
+XZCP1141L10 (6) (7)

XU2M18PP340L5

XUB0BPSNL5
+XUB0BKSNL5T (6)

XU2M18PP340W

XUB2BPAWL2R
+XUB2BKSWL2T (4) (6)

XUB1BNBWL2+XUZC50 (3)
XU1N18NP340WD

XUB1BNAWM12+XUZC50 (2)
XUB1BNBWM12+XUZC50 (3)

XU1N18PP340

XUB1BPANL2+XUZC50 (4)
XUB1BPBNL2+XUZC50 (5)

XU1N18PP340D

XUB1BPANM12+XUZC50 (4)
XUB1BPBNM12+XUZC50 (5)

XU1N18PP340L5

XUB1BPANL5+XUZC50 (4)

XUB2BPBWL2R
+XUB2BKSWL2T (5) (6)

XUB1BPBNL5+XUZC50 (5)
XU1N18PP340W

XUB1BPAWL2+XUZC50 (4)
XUB1BPBWL2+XUZC50 (5)

XU1N18PP340WD

XU1N18PP340WL5

XU2M18PP340WD

XUB1BPAWL5+XUZC50 (4)

XU2M18PP340WL5

XUB1BPBWL5+XUZC50 (5)
XU1P18NP340

XU2N18NP340

XUB1ANANM12+XUZC50 (2)

XUB1ANANL5+XUZC50 (2)

XU2N18NP340D

XUB1ANBNL5+XUZC50 (3)
XU1P18NP340W

XU2N18NP340WD

XUB1ANAWM12+XUZC50 (2)

XUB1APANL2+XUZC50 (4)
XUB1APBNL2+XUZC50 (5)

XU1P18PP340D

XU1P18PP340L5

XU2N18PP340

XUB1APANL5+XUZC50 (4)

XU2N18PP340D

XUB1APBNL5+XUZC50 (5)
XU1P18PP340W

XU1P18PP340WD

XU2N18PP340L5

XUB1APAWM12+XUZC50 (4)

XUB1APAWL5+XUZC50 (4)
XUB1APBWL5+XUZC50 (5)

XU2B18NP340

XUB0ANSNL2
+XUB0AKSNL2T

XUB2BPANM12R
+XUB2BKSNM12T (4)

XU2P18NP340

XU2N18PP340W

XUB2ANANL2R
+XUB2AKSNL2T (2)
XUB2ANBNL2R
+XUB2AKSNL2T (3)

XU2P18NP340D

XUB2ANANM12R
+XUB2AKSNM12T (2)
XUB2ANBNM12R
+XUB2AKSNM12T (3)

XU2P18NP340W

XUB2ANAWL2R
+XUB2AKSWL2T (2)
XUB2ANBWL2R
+XUB2AKSWL2T (3)

XU2P18NP340WD

XUB2ANAWM12R
+XUB2AKSWM12T (2)
XUB2ANBWM12R
+XUB2AKSWM12T (3)

XU2P18PP340

XUB2APANL2R
+XUB2AKSNL2T (4)
XUB2APBNL2R
+XUB2AKSNL2T (5)

XU2P18PP340D

XUB2APANM12R
+XUB2AKSNM12T (4)
XUB2APBNM12R
+XUB2AKSNM12T (5)

XU2P18PP340L10

XUB0APSNM12
+XUB0AKSNM12T
+XZCP1141L10 (6) (7)

XU2P18PP340L5

XUB2APANL5R
+XUB2AKSNL5T (4)
XUB2APBNL5R
+XUB2AKSNL5T (5)

XU2P18PP340W

XUB2APAWL2R
+XUB2AKSWL2T (4)
XUB2APBWL2R
+XUB2AKSWL2T (5)

XU2P18PP340WD

XUB2APAWM12R
+XUB2AKSWM12T (4)
XUB2APBWM12R
+XUB2AKSWM12T (5)

XU5B18NP340

XUB0ANSNL2 (8)

XU5B18NP340D

XUB0ANSNM12 (8)

XU5B18PP340

XUB0APSNL2 (8)

XU5B18PP340D

XUB0APSNM12 (8)

XU5B18PP340L5

XUB0APSNL5 (8)

XU5M18NP340

XUB0BNSNL2 (8)

XU5M18NP340D

XUB0BNSNM12 (8)

XU5M18NP340L5

XUB0BNSNL5 (8)

XU5M18NP340W

XUB5BNAWL2 (2)

XUB2BPAWL2R
+XUB2BKSWL2T (4)

XU5M18NP340WL5

XUB5BNAWL5 (2)

XUB2BPBWL2R
+XUB2BKSWL2T (5)

XU5M18PP340

XUB0BPSNL2 (8)

XU5M18PP340D

XUB0BPSNM12 (8)

XUB2BPANL5R
+XUB2BKSNL5T (4)
XUB2BPBNL5R
+XUB2BKSNL5T (5)

XUB1APBWM12+XUZC50 (5)
XU1P18PP340WL5

XUB2BPANL2R
+XUB2BKSNL2T (4)

XUB2BPBNM12R
+XUB2BKSNM12T (5)

XUB1APAWL2+XUZC50 (4)
XUB1APBWL2+XUZC50 (5)

XUB2BNAWM12R
+XUB2BKSWM12T (2)

XUB2BPBNL2R
+XUB2BKSNL2T (5)

XUB1APANM12+XUZC50 (4)
XUB1APBNM12+XUZC50 (5)

XUB2BNANM12R
+XUB2BKSNM12T (2)

XUB2BPAWL5R
+XUB2BKSWL5T (4)
XUB2BPBWL5R
+XUB2BKSWL5T (5)

XUB2BNBWM12R
+XUB2BKSWM12T (3)

XUB1ANBWM12+XUZC50 (3)
XU1P18PP340

XU2N18PP340WL5

XUB2BNBNM12R
+XUB2BKSNM12T (3)

XUB1ANAWL2+XUZC50 (2)
XUB1ANBWL2+XUZC50 (3)

XU1P18NP340WD

XUB2BNANL2R
+XUB2BKSNL2T (2)

XUB2BPBWM12R
+XUB2BKAWM12T (5)

XUB2BNBNL2R
+XUB2BKSNL2T (3)

XUB1ANBNM12+XUZC50 (3)
XU1P18NP340L5

XUB2BPAWL5R
+XUB2BKSWL5T (4) (6)
XUB2BPBWL5R
+XUB2BKSWL5T (5) (6)

XUB1ANANL2+XUZC50 (2)
XUB1ANBNL2+XUZC50 (3)

XU1P18NP340D

XUB2BPAWM12R
+XUB2BKSWM12T (4) (6)
XUB2BPBWM12R
+XUB2BKSWM12T (5) (6)

XUB1BPAWM12+XUZC50 (4)
XUB1BPBWM12+XUZC50 (5)

XUB5BNBWL2 (3)

XUB5BNBWL5 (3)

Note: XUZC50 is a 50 x 50 mm reflector, XUZA5p and XUZX2000 are metal fixing brackets and XUZX2001 is an M16 to 1/2" NPT adaptor (see pages 5/158 and 5/159).
(1) Sn = 2 m instead of 4 m.
(2) Sensor output NO, PNP connection.
(3) Sensor output NC, NPN connection.
(4) Sensor output NO, PNP connection.
(5) Sensor output NC, PNP connection.

5/174

(6) M18 threaded length = 44 mm instead of 50/55 mm.


(7) For a cable length = 10 m, the use of an M12 connector
version sensor combined with an XZCP1141L10 jumper
cable (M12 with 10 m cable) is recommended.

(8) Sn = 0.3 m instead of 0.4 m. For a sensing distance Sn


greater than 0.3 m, see references XUB5pppppp on page
5/26.

Substitution table

Old sensor

New OsiSense XU sensor

Diameter 18 mm sensors (continued)


XU5M18PP340L5

XUB0BPSNL5 (8)

XU5M18PP340W

XUB5BPAWL2 (4)

Photo-electric sensors

Old sensor

New OsiSense XU sensor

Old sensor

New OsiSense XU sensor

XU5P18PP340W

XUB4APAWL2 (4)

XU9P18NP340

XUB0ANSNL2+XUZC50 (6)

XUB4APBWL2 (5)

XU9P18NP340D

XUB0ANSNM12+XUZC50 (6)

XUB4APAWM12 (4)

XU9P18NP340L5

XUB0ANSNL5+XUZC50 (6)

XUB4APBWM12 (5)

XU9P18NP340W

XUB0ANSWL2+XUZC50 (6)

XUB4APAWL5 (4)

XU9P18NP340WD

XUB0ANSWM12+XUZC50 (6)

XUB4APBWL5 (5)

XU9P18PP340

XUB0APSNL2+XUZC50 (6)

XU5P18PP340WD

XUB5BPBWL2 (5)
XU5M18PP340WD

XUB5BPAWM12 (4)

XU5P18PP340WL5

XUB5BPBWM12 (5)
XU5M18PP340WL5

XU5N18NP340

XU5N18NP340D

XUB5BPAWL5 (4)

XU8B18NP340

XUB0ANSNL2

XU9P18PP340D

XUB0APSNM12+XUZC50 (6)

XUB5BPBWL5 (5)

XU8B18NP340D

XUB0ANSNM12

XU9P18PP340W

XUB0APSWL2+XUZC50 (6)

XUB4BNANL2 (2)

XU8B18PP340

XUB0APSNL2

XU9P18PP340WD

XUB0APSWM12+XUZC50 (6)

XUB4BNBNL2 (3)

XU8B18PP340D

XUB0APSNM12

XU9P18PP340WL5

XUB0APSWL5+XUZC50 (6)

XUB4BNANM12 (2)

XU8B18PP340L10

XUB0APSNM12
+XZCP1141L10 (7)

XU8M18NP340

XUB0BNSNL2 (6)

XU8M18NP340D

XUB0BNSNM12 (6)

XUB4BNBNM12 (3)
XU5N18NP340L5

XUB4BNANL5 (2)
XUB4BNBNL5 (3)

XU5N18NP340W

XUB4BNAWL2 (2)
XUB4BNBWL2 (3)

XU5N18NP340WD

XUB4BNAWM12 (2)
XUB4BNBWM12 (3)

XU5N18NP340WL5

XUB4BNANL5 (2)
XUB4BNBNL5 (3)

XU5N18PP340

XUB4BPANL2 (4)

XU5N18PP340D

XUB4BPANM12 (4)

XUB4BPBNL2 (5)

XUB4BPBNM12 (5)
XU5N18PP340L5

XUB4BPANL5 (4)
XUB4BPBNL5 (5)

XU5N18PP340W

XUB4BPAWL2 (4)
XUB4BPBWL2 (5)

XU5N18PP340WD

XUB4BPAWM12 (4)
XUB4BPBWM12 (5)

XU5N18PP340WL5

XUB4BPANL5 (4)

XU5P18NP340

XUB4ANANL2 (2)

XUB4BPBNL5 (5)

XUB4ANBNL2 (3)
XU5P18NP340D

XUB4ANANM12 (2)
XUB4ANBNM12 (3)

XU5P18NP340L5

XUB4ANANL5 (2)

XU5P18NP340W

XUB4ANAWL2 (2)

XU5P18NP340WD

XUB4ANAWM12 (2)

XUB4ANBNL5 (3)

XUB4ANBWL2 (3)

XUB4ANBWM12 (3)
XU5P18PP340

XUB4APANL2 (2)
XUB4APBNL2 (3)

XU5P18PP340D

XUB4APANM12 (2)
XUB4APBNM12 (3)

XU5P18PP340L10

XUB4APANM12
+XZCP1141L10 (4) (7)
XUB4APBNM12
+XZCP1141L10 (5) (7)

XU5P18PP340L5

XUB4APANL5 (4)
XUB4APBNL5 (5)

XU8M18NP340L5

XUB0BNSNL5 (6)

XU8M18NP340W

XUB0BNSWL2 (6)

XU8M18NP340WD

XUB0BNSWM12 (6)

XU8M18PP340

XUB0BPSNL2 (6)

XU8M18PP340D

XUB0BPSNM12 (6)

XU8M18PP340L5

XUB0BPSNL5 (6)

XU8M18PP340W

XUB0BPSWL2 (6)

XU8M18PP340WD

XUB0BPSWM12 (6)

XU9B18NP340

XUB0ANSNL2+XUZC50

XU9B18NP340D

XUB0ANSNM12+XUZC50

XU9B18PP340

XUB0APSNL2+XUZC50

XU9B18PP340D

XUB0APSNM12+XUZC50

XU9B18PP340L5

XUB0APSNL5+XUZC50

XU9M18NP340

XUB0BNSNL2+XUZC50 (6)

XU9M18NP340D

XUB0BNSNM12+XUZC50 (6)

XU9M18NP340L5

XUB0BNSNL5+XUZC50 (6)

XU9M18NP340W

XUB9BNAWL2+XUZC50 (2) (9)


XUB9BNBWL2+XUZC50 (3)(9)

XU9M18PP340

XUB0BPSNL2+XUZC50 (6)

XU9M18PP340D

XUB0BPSNM12+XUZC50 (6)

XU9M18PP340L5

XUB0BPSNL5+XUZC50 (6)

XU9M18PP340W

XUB9BPAWL2+XUZC50 (4) (9)


XUB9BPBWL2+XUZC50 (5) (9)

XU9M18PP340WD

XUB9BPAWM12+XUZC50 (4)(9)
XUB9BPBWM12+XUZC50 (5)(9)

XU9M18PP340WL5

XUB9BPAWL5+XUZC50 (4) (9)


XUB9BPBWL5+XUZC50 (5) (9)

XU9N18NP340

XUB0BNSNL2+XUZC50 (6)

XU9N18NP340D

XUB0BNSNM12+XUZC50 (6)

XU9N18NP340L5

XUB0BNSNL5+XUZC50 (6)

XU9N18NP340W

XUB0BNSWL2+XUZC50 (6)

XU9N18NP340WD

XUB0BNSWM12+XUZC50 (6)

XU9N18PP340

XUB0BPSNL2+XUZC50 (6)

XU9N18PP340D

XUB0BPSNM12+XUZC50 (6)

XU9N18PP340L5

XUB0BPSNL5+XUZC50 (6)

XU9N18PP340W

XUB0BPSWL2+XUZC50 (6)

XU9N18PP340WD

XUB0BPSWM12+XUZC50 (6)

XU9N18PP340WL5

XUB0BPSWL5+XUZC50 (6)

Amplifiers for fibre optics


XUDH003537

XUDA1PSML2

XUDH003537S

XUDA1PSMM8

XUDH003937

XUDA2PSML2

XUDH003937S

XUDA2PSMM8

XUDJ003537

XUDA1NSML2

XUDJ003537S

XUDA1NSMM8

XUDJ003937

XUDA2NSML2

XUDJ003937S

XUDA2NSMM8

1
2
3
4

Compact design sensors type XUE


XUEF010315

XUX0ARCTT16+XUZX2000 (10)

XUEF010315H7

XUX0ARCTT16
+XUZX2000+XUZX2001

XUEF080319

XUX0ARCTT16+XUZX2000
+XUZC50 (10)

XUEF080319H4

XUX0ARCTT16 +XUZX2000
+XUZX2001+XUZC50

XUEF10031

XUX0ARCTT16+XUZX2000
+XUZC50 (10) (11)

XUEF10031H7

XUX0ARCTT16 +XUZX2000
+XUZX2001+XUZC50 (11)

XUEF300314

XUX0ARCTT16+XUZX2000 (10)
(12)

XUEF300314H7

XUX0ARCTT16+XUZX2000
+XUZX2001 (12)

XUEH017535

XUX0AKSAT16+XUZX2000 (10)
(13)

XUEH017535H7

XUX0AKSAT16+XUZX2000
+XUZX2001 (13)

XUEH10753

XUX0AKSAT16+XUZX2000 (10)
(13)

XUEH10753H7

XUX0AKSAT16+XUZX2000
+XUZX2001 (13)

XUEH3000

XUX0ARCTT16T+XUZX2000 (10)
(12)

XUEH3000H7

XUX0ARCTT16T+XUZX2000
+XUZX2001 (12)

XUEH307534

XUX0AKSAT16+XUZX2000
(10) (12) (13)

XUEH307534H7

XUX0AKSAT16+XUZX2000
+XUZX2001 (12) (13)

XUEH753538

XUX8AKSAT16+XUZX2000
(10) (13)

XUEH753538H4

XUX8AKSAT16+XUZX2000
+XUZX2001 (13)

XUET010315

XUX0ARCTT16+XUZX2000 (10)
(14)

Note: XUZC50 is a 50 x 50 mm reflector, XUZA5p and XUZX2000 are metal fixing brackets and XUZX2001 is an M16 to 1/2" NPT adaptor (see pages 5/158 and 5/159)
(2) Sensor output NO, PNP connection.
cable (M12 with 10 m cable) is recommended.
(11) Sn = 11 m instead of 15 m.
(3) Sensor output NC, NPN connection.
(8) Sn = 0.3 m instead of 0.4 m. For a sensing distance Sn
(12) Sn = 40 m instead of 50 m.
(4) Sensor output NO, PNP connection.
greater than 0.3 m, see references XUB5pppppp on page
(13) Output current switching capacity = 100 mA instead of
(5) Sensor output NC, PNP connection.
5/26.
200 mA
(6) M18 threaded length = 44 mm instead of 50/55 mm.
(9) M18 threaded length = 28 mm instead of 55 mm.
(14) Time delay relay output 0.02...15 s instead of
(7) For a cable length = 10 m, the use of an M12 connector
(10) Sensor with M16 threaded cable entry instead of
0.0360s.
version sensor combined with an XZCP1141L10 jumper
Pg13.5.

5/175

5
6
7
8
9
10


Substitution
table

Sensors with the closest


functionalities

Old sensor

New OsiSense XU sensor

Compact design sensors type XUE (continued)

Photo-electric sensors

Old sensor

New OsiSense XU sensor

Old sensor

New OsiSense XU sensor

XUJLM0619H7

XUX9ARCNT16+XUZX2000
+XUZX2001 +XUZC50

XUJM700318D1

XUX8ARCTT16+XUZX2000

XUJM700318D2

XUX8ARCTT16+XUZX2000

XUJM700318H7

XUX8ARCTT16+XUZX2000
+XUZX2001

XUX0ARCTT16 +XUZX2000
+XUZX2001 (14)

XUJLM0619P9

XUET080319

XUX0ARCTT16+XUZX2000
+XUZC50 (10) (14)

XUX9ARCNT16+XUZX2000
+XUZC50 (16)

XUJLM0811

XUX0ARCTT16 +XUZX2000
+XUZX2001+XUZC50 (14)

XUX1ARCNT16+XUZX2000
+XUZC50 (15)

XUJM700318P9

XUET080319H4

XUX8ARCTT16+XUZX2000 (16)

XUJLM0811H7

XUJT06031

XUET10031

XUX0ARCTT16+XUZX2000
+XUZC50 (10) (11) (14)

XUX1ARCNT16+XUZX2000
+XUZX2001 +XUZC50

XUX0ARCTT16+XUZX2000
+XUZC50 (15)

XUJLM0811P9

XUX0ARCTT16 +XUZX2000
+XUZX2001+XUZC50 (11) (14)

XUX1ARCNT16+XUZX2000
+XUZC50 (16)

XUJT060319

XUET10031H7

XUX0ARCTT16+XUZX2000
+XUZC50 (15)

XUJLM1503

XUX0ARCTT16T+XUZX2000 (15)

XUJT060319D1

XUET300314

XUX0ARCTT16+XUZX2000 (10)
(12) (14)

XUX0ARCTT16+XUZX2000
+XUZC50

XUJLM1503H7

XUJT060319D2

XUET300314H7

XUX0ARCTT16+XUZX2000
+XUZX2001 (12) (14)

XUX0ARCTT16T+XUZX2000
+XUZX2001

XUX0ARCTT16+XUZX2000
+XUZC50

XUJLM1503P9

XUX0ARCTT16T + XUZX2000 (16)

XUJT060319H7

XUX0ARCTT16+XUZX2000
+XUZC50+XUZX2001

XUJLM1514

XUX2ARCNT16R+XUZX2000 (15)

XUJT060319P9

XUX0ARCTT16+XUZX2000
+XUZC50 (16)

XUET010315H7

Compact design sensors type XUJ


XUJK06353

XUX0AKSAT16+XUZX2000
+XUZC50 (13) (15)

XUJLM1514H7

XUJT06031D1

XUX0ARCTT16+XUZX2000
+XUZC50

XUJK063539

XUX0AKSAT16+XUZX2000
+XUZC50 (13) (15)

XUX2ARCNT16R+XUZX2000
+XUZX2001

XUJLM1514P9

XUX2ARCNT16R+XUZX2000 (16)

XUJT06031D2

XUX0ARCTT16+XUZX2000
+XUZC50

XUJK063539D1

XUX0AKSAM12+XUZX2000
+XUZC50(13)

XUJM06031

XUJT06031H7

XUX0ARCTT16+XUZX2000
+XUZC50+XUZX2001

XUJK063539D2

XUX0AKSAM12+XUZX2000
+XUZC50(13)

XUX1ARCNT16+XUZX2000
+XUZC50 (15)

XUJM060319

XUJT06031P9

XUX0ARCTT16+XUZX2000
+XUZC50 (16)

XUJK063539H7

XUX0AKSAT16+XUZX2000
+XUZC50 +XUZX2001 (13)

XUX9ARCNT16+XUZX2000
+XUZC50 (16)

XUJM060319D1

XUJK063539P9

XUX0AKSAT16+XUZX2000
+XUZC50 (13) (16)

XUX9ARCNT16+XUZX2000
+XUZC50

XUJM060319D2

XUJK06353D1

XUX0AKSAM12+XUZX2000
+XUZC50(13)

XUJM060319H7

XUJK06353D2

XUX0AKSAM12+XUZX2000
+XUZC50(13)

XUX9ARCNT16+XUZX2000
+XUZX2001+XUZC50

XUJM060319P9

XUJK06353H7

XUX0AKSAT16+XUZX2000
+XUZC50 +XUZX2001 (13)

XUX9ARCNT16+XUZX2000
+XUZC50 (16)

XUJM06031D1

XUJK06353P9

XUX0AKSAT16+XUZX2000
+XUZC50 (13) (16)

XUX1ARCNT16+XUZX2000
+XUZC50

XUJM06031D2

XUJK103534

XUX0AKSAT16+XUZX2000
(13)(15)

XUX1ARCNT16+XUZX2000
+XUZC50

XUJM06031H7

XUJK103534D1

XUX0AKSAM12+XUZX2000 (13)

XUX1ARCNT16+XUZX2000
+XUZX2001 +XUZC50

XUJK103534D2

XUX0AKSAM12+XUZX2000 (13)

XUJK103534H7

XUX0AKSAT16+XUZX2000
+XUZX2001 (13)

XUX9ARCNT16+XUZX2000
+XUZC50

XUJT100314

XUX0ARCTT16+XUZX2000 (15)

XUJT100314D1

XUX0ARCTT16+XUZX2000

XUJT100314D2

XUX0ARCTT16+XUZX2000

XUJT100314H7

XUX0ARCTT16+XUZX2000
+XUZX2001

XUJT100314P9

XUX0ARCTT16+XUZX2000 (16)

XUJT120318

XUX8ARCTT16+XUZX2000 (15)

XUJT120318D1

XUX8ARCTT16+XUZX2000

XUJT120318D2

XUX8ARCTT16+XUZX2000

XUJT120318H7

XUX8ARCTT16+XUZX2000
+XUZX2001

XUJT120318P9

XUX8ARCTT16+XUZX2000 (16)

XUX1ARCNT16+XUZX2000
+XUZC50 (16)

XUJT700318

XUX8ARCTT16+XUZX2000 (15)

XUJT700318D1

XUX8ARCTT16+XUZX2000

XUJM1000

XUX0AKSAT16T+XUZX2000(15)

XUJT700318D2

XUX8ARCTT16+XUZX2000

XUJM1000D1

XUX0AKSAM12T+XUZX2000

XUJT700318H7

XUJM1000D2

XUX0AKSAM12T+XUZX2000

XUX8ARCTT16+XUZX2000
+XUZX2001
XUX8ARCTT16+XUZX2000 (16)

XUJM06031P9

XUJK103534P9

XUX0AKSAT16+XUZX2000
(13)(16)

XUJK123538

XUX8AKSAT16+XUZX2000
(13)(15)

XUJM1000H7

XUX0AKSAT16T+XUZX2000
+XUZX2001

XUJT700318P9

XUJK123538D1

XUX8AKSAM12+XUZX2000 (13)

XUJM1000P9

XUX0AKSAT16T+XUZX2000(16)

Compact design sensors type XUK

XUJK123538D2

XUX8AKSAM12+XUZX2000 (13)

XUJM100314

XUX0ARCTT16+XUZX2000 (15)

XUK1ARCTL10

XUJK123538H7

XUX8AKSAT16+XUZX2000
+XUZX2001 (13)

XUJM100314D1

XUX0ARCTT16+XUZX2000

XUK1ARCNL10+XUZA51 +
XUZC50

XUJM100314D2

XUX0ARCTT16+XUZX2000

XUK1ARCTL2

XUJK123538P9

XUX8AKSAT16+XUZX2000
(13)(16)

XUK1ARCNL2+XUZA51 +
XUZC50

XUJM100314H7

XUX0ARCTT16+XUZX2000
+XUZX2001

XUK2AKSAL10

XUJK703538

XUX8AKSAT16+XUZX2000
(13)(15)

XUK2APANL10R
+XUK0AKSNL10T
+2 x XUZA51 (4)

XUJK703538D1

XUX8AKSAM12+XUZX2000 (13)

XUJK703538D2

XUX8AKSAM12+XUZX2000 (13)

XUJK703538H7

XUX8AKSAT16+XUZX2000
+XUZX2001 (13)

XUJK703538P9

XUX8AKSAT16+XUZX2000
(13)(16)

XUJLM0619

XUX9ARCNT16+XUZX2000
+XUZC50 (15)

XUJM100314P9

XUX0ARCTT16+XUZX2000 (16)

XUJM120318

XUX8ARCTT16+XUZX2000 (15)

XUJM120318D1

XUX8ARCTT16+XUZX2000

XUJM120318D2

XUX8ARCTT16+XUZX2000

XUJM120318H7

XUX8ARCTT16+XUZX2000
+XUZX2001

XUJM120318P9

XUX8ARCTT16+XUZX2000 (16)

XUJM700318

XUX8ARCTT16+XUZX2000 (15)

XUK2APBNL10R
+XUK0AKSNL10T
+2 x XUZA51 (5)
XUK2ANANL10R
+XUK0AKSNL10T
+2 x XUZA51 (2)
XUK2ANBNL10R
+XUK0AKSNL10T
+2 x XUZA51 (3)

Note: XUZC50 is a 50 x 50 mm reflector, XUZA5p and XUZX2000 are metal fixing brackets and XUZX2001 is an M16 to 1/2" NPT adaptor (see pages 5/158 and 5/159).
(2) Sensor output NO, PNP connection.
(3) Sensor output NC, NPN connection.
(4) Sensor output NO, PNP connection.
(5) Sensor output NC, PNP connection.
(10) Sensor with M16 threaded cable entry instead of Pg13.
(11) Sn = 11 m instead of 15 m.

5/176

(12) Sn = 40 m instead of 50 m.
(13) Output current switching capacity = 100 mA instead of
200 mA.
(14) Time delay relay output 0.02...15 s instead of 0.0360s.
(15) Sensor with M16 threaded cable entry instead of Pg11.
(16) Sensor with M16 threaded cable entry instead of Pg9.

Substitution table

Old sensor

New OsiSense XU sensor

Compact design sensors type XUK (continued)


XUK2AKSAL2

Photo-electric sensors

Old sensor

New OsiSense XU sensor

XUK9AKSAM12

XUK9APANM12+XUZA51
+XUZC50 (4)

XUK2APANL2R
+XUK0AKSNL2T
+2 x XUZA51 (4)

XUK9APBNM12+XUZA51
+XUZC50 (5)
XUK9ANANM12+XUZA51
+XUZC50 (2)

XUK2APBNL2R +XUK0AKSNL2T
+2 x XUZA51 (5)
XUK2ANANL2R
+XUK0AKSNL2T
+2 x XUZA51 (2)
XUK2ANBNL2R
+XUK0AKSNL2T
+2 x XUZA51 (3)
XUK2AKSAM12

XUK2APANM12R
+XUK0AKSNM12T
+2 x XUZA51 (4)

XUK2ARCTL2

XUK5AKSAL10

XUK5AKSAL2

XUK9ARCTL10
XUK9ARCTL2

XUK9ARCNL10+XUZA51
+XUZC50
XUK9ARCNL2+XUZA51
+XUZC50

Compact design sensors type XUL


XULH153538

XUK8AKSNL2+XUZA51 (13)

XULH153538D

XUK8AKSNM12+XUZA51 (13)

XULH153538H7

XUK8AKSNM12+XUZA51 (13)

XUK2ANANM12R
+XUK0AKSNM12T
+2 x XUZA51 (2)

XULH153538L05

XUK8AKSNL5+XUZA51 (13)

XULH153538L10

XUK8AKSNL10+XUZA51 (13)

XUK2ANBNM12R
+XUK0AKSNM12T
+2 x XUZA51 (3)

XULH303538

XUK8AKSNL2+XUZA51 (13)

XULH303538D

XUK8AKSNM12+XUZA51 (13)

XUK2APBNM12R
+XUK0AKSNM12T
+2 x XUZA51 (5)

XUK2ARCTL10

XUK9ANBNM12+XUZA51
+XUZC50 (3)

XUK0ARCTL10
+XUK0ARCTL10T
+2 x XUZA51

XULH303538DH7

XUK8AKSNM12+XUZA51 (13)

XULH303538L05

XUK8AKSNL5+XUZA51 (13)

XUK0ARCTL2
+XUK0ARCTL2T
+2 x XUZA51

XULH303538L10

XUK8AKSNL10+XUZA51 (13)

XULJ153538

XUK8AKSNL2+XUZA51 (13)

XULJ153538D

XUK8AKSNM12+XUZA51 (13)

XUK5APANL10+XUZA51 (4)

XULJ153538H7

XUK8AKSNM12+XUZA51 (13)

XUK5APBNL10+XUZA51 (5)

XULJ153538L05

XUK8AKSNL5+XUZA51 (13)

XUK5ANANL10+XUZA51 (2)

XULJ303538

XUK8AKSNL2+XUZA51 (13)

XUK5ANBNL10+XUZA51 (3)

XULJ303538D

XUK8AKSNM12+XUZA51 (13)

XUK5APANL2+XUZA51 (4)

XULJ303538L05

XUK8AKSNL5+XUZA51 (13)

XUK5APBNL2+XUZA51 (5)
XUK5ANANL2+XUZA51 (2)

XUK5AKSAM12

Compact design sensors type XUM

Old sensor

New OsiSense XU sensor

XUM2ANBNL2R

XUM2ANCNL2R (17)

XUM2ANBNM8R

XUM2ANCNM8R (17)

XUM2APANL2R

XUM2APCNL2R (17)

XUM2APANL5R

XUM2APCNM8R+XZCP0941L5
(17)

XUM2APANM8R

XUM2APCNM8R (17)

XUM2APBNL2R

XUM2APCNL2R (17)

XUM2APBNL5R

XUM2APCNM8R+XZCP0941L5
(17)

XUM2APBNM8R

XUM2APCNM8R (17)

XUM5ANANL2

XUM5ANCNL2 (17)

XUM5ANANM8

XUM5ANCNM8 (17)

XUM5ANBNL2

XUM5ANCNL2 (17)

XUM5ANBNM8

XUM5ANCNM8 (17)

XUM5APANL2

XUM5APCNL2 (17)

XUM5APANL5

XUM5APCNM8+XZCP0941L5 (17)

XUM5APANM8

XUM5APCNM8 (17)

XUM5APBNL2

XUM5APCNL2 (17)

XUM5APBNL5

XUM5APCNM8+XZCP0941L5 (17)

XUM5APBNM8

XUM5APCNM8 (17)

XUM6ANANL2

XUM5ANCNL2 (17)

XUM6ANANM8

XUM5ANCNM8 (17)

XUM6ANBNL2

XUM5ANCNL2 (17)

XUM6ANBNM8

XUM5ANCNM8 (17)

XUM6APANL2

XUM5APCNL2 (17)

XUM6APANL5

XUM5APCNM8+XZCP0941L5 (17)

XUM6APANM8

XUM5APCNM8 (17)

XUM6APBNL2

XUM5APCNL2 (17)

XUM6APBNL5

XUM5APCNM8+XZCP0941L5 (17)

XUM6APBNM8

XUM5APCNM8 (17)

XUM9ANANL2

XUM9ANCNL2 (17)

XUM9ANANL5

XUM9ANCNM8+XZCP0941L5 (17)

XUK5ANBNL2+XUZA51 (3)

XUM1ANANL2

XUM9ANCNL2 (17)

XUM9ANANM8

XUM9ANCNM8 (17)

XUK5APANM12+XUZA51 (4)

XUM1ANANL5

XUM9ANCNM8+XZCP0941L5 (17)

XUM9ANBNL2

XUM9ANCNL2 (17)

XUK5APBNM12+XUZA51 (5)

XUM1ANANM8

XUM9ANCNM8 (17)

XUM9ANBNM8

XUM9ANCNM8 (17)

XUM9APANL2

XUM9APCNL2 (17)

XUK5ANANM12+XUZA51 (2)

XUM1ANBNL2

XUM9ANCNL2 (17)

XUK5ANBNM12+XUZA51 (3)

XUM1ANBNM8

XUM9ANCNM8 (17)

XUM9APANL5

XUM9APCNM8+XZCP0941L5 (17)

XUK5ARCTL10

XUK5ARCNL10+XUZA51

XUM1APANL10

XUM9APANM8

XUM9APCNM8 (17)

XUK5ARCTL2

XUK5ARCNL2+XUZA51

XUM9APCNM8+XZCP0941L10
(17)

XUM1APANL2

XUM9APCNL2 (17)

XUK9AKSAL10

XUK9APANL10+XUZA51
+XUZC50 (4)

XUM1APANL5

XUM9APCNM8+XZCP0941L5 (17)

XUK9APBNL10+XUZA51
+XUZC50 (5)

XUM1APANM8

XUM9APCNM8 (17)

XUM1APBNL10

XUK9ANANL10+XUZA51
+XUZC50 (2)

XUM9APCNM8+XZCP0941L10
(17)

XUM1APBNL2

XUM9APCNL2 (17)

XUK9ANBNL10+XUZA51
+XUZC50 (3)
XUK9AKSAL2

XUK9APANL2+XUZA51 +XUZC50
(4)
XUK9APBNL2+XUZA51 +XUZC50
(5)
XUK9ANANL2+XUZA51
+XUZC50 (2)
XUK9ANBNL2+XUZA51
+XUZC50 (3)

XUM1APBNL5

XUM9APCNM8+XZCP0941L5 (17)

XUM1APBNM8

XUM9APCNM8 (17)

XUM2AKSNL2T

XUM2AKCNL2T (17)

XUM2AKSNL5T

XUM2AKCNM8T+XZCP0941L5
(17)

XUM2AKSNM8T

XUM2AKCNM8T (17)

XUM2ANANL2R

XUM2ANCNL2R (17)

XUM2ANANL5R

XUM2ANCNM8R+XZCP0941L5
(17)

XUM2ANANM8R

XUM2ANCNM8R (17)

XUM9APBNL2

XUM9APCNL2 (17)

XUM9APBNL5

XUM9APCNM8+XZCP0941L5 (17)

XUM9APBNM8

XUM9APCNM8 (17)

(5) Sensor output NC, PNP connection.


(13) Output current switching capacity = 100 mA instead of
200 mA.

4
5
6
7
8
9
10

Note: XUZC50 is a 50 x 50 mm reflector, XUZA5p and XUZX2000 are metal fixing brackets and XUZX2001 is an M16 to 1/2" NPT adaptor (see pages 5/158 and 5/159).
(2) Sensor output NO, PNP connection.
(3) Sensor output NC, NPN connection.
(4) Sensor output NO, PNP connection.

(17) Sensor with NO/NC outputs.

5/177

Anda mungkin juga menyukai