Anda di halaman 1dari 32

DEVICE SPECIFICATIONS

NI PXIe-4138
Single-Channel System SMU
This document lists specifications for the NI PXIe-4138 (NI 4138) system source-measure unit
(SMU).
Specifications are subject to change without notice. For the most recent NI 4138
specifications, visit ni.com/manuals.
Caution Using the NI 4138 in a manner not described in this document might

impair the protection the NI 4138 provides.


Caution Refer to the Read Me First: Safety and Electromagnetic Compatibility

document for important safety and electromagnetic compatibility information. To


obtain a copy of this document online, visit ni.com/manuals and search for the
document title.
Caution To ensure the specified EMC performance, operate this product only with

shielded cables and accessories.


Caution To ensure the specified EMC performance, the length of all I/O cables

must be no longer than 3 m (10 ft).


Attention This icon denotes a warning advising you to take precautions to avoid

electrical shock.
National Instruments defines the capabilities and performance of its Test & Measurement
instruments as Specifications, Typical Specifications, and Characteristic or Supplemental
Specifications. Data provided in this document are Specifications unless otherwise noted.
Specifications characterize the warranted performance of the instrument within the
recommended calibration interval and under the stated operating conditions.
Typical Specifications are specifications met by the majority of the instruments within the
recommended calibration interval and under the stated operating conditions. The performance
of the instrument is not warranted.
Characteristic or Supplemental Specifications describe basic functions and attributes of the
instrument established by design or during development and not evaluated during Verification
or Adjustment. They provide information that is relevant for the adequate use of the
instrument that is not included in the previous definitions.

Unless otherwise noted, specifications are valid under the following conditions:
Ensure an ambient temperature of 23 C 5 C.

Ensure a calibration interval of 1 year.

Allow 30 minutes warm-up time.

Perform self-calibration within the last 24 hours.

Set the niDCPower Aperture Time property or


NIDCPOWER_ATTR_APERTURE_TIME attribute to 2 power-line cycles (PLCs).

If the PXI Express chassis has multiple fan speed settings, ensure the fans are set to the
highest setting.
To access NI 4138 documentation, navigate to StartAll ProgramsNational Instruments
NI-DCPowerDocumentation.

Contents
Cleaning Statement...................................................................................................................3
Device Capabilities...................................................................................................................3
Voltage Programming and Measurement Accuracy/Resolution...............................................4
Current Programming and Measurement Accuracy/Resolution...............................................5
Noise, Typical...........................................................................................................................5
Sinking Power vs. Ambient Temperature Derating..................................................................5
Transient Response and Settling Time, Typical.......................................................................6
Load Regulation, Typical..........................................................................................................7
Measurement and Update Timing Characteristics....................................................................8
NI-DCPower Sequence Source Model.....................................................................................8
Absolute Maximum Limit Characteristics................................................................................9
Protection Characteristics.........................................................................................................9
Isolation Characteristics..........................................................................................................10
Guard Output Characteristics..................................................................................................10
Accessories..............................................................................................................................10
Calibration Interval.................................................................................................................10
Power Requirement Characteristics........................................................................................11
Physical Characteristics..........................................................................................................11
Environment............................................................................................................................12
Operating Environment...................................................................................................13
Storage Environment.......................................................................................................13
Compliance and Certifications................................................................................................13
Safety..............................................................................................................................13
Electromagnetic Compatibility.......................................................................................13
CE Compliance ..............................................................................................................14
Online Product Certification...........................................................................................14
Environmental Management...........................................................................................14

ni.com

NI PXIe-4138 Specifications

Cleaning Statement
Caution Clean the hardware with a soft, nonmetallic brush. Make sure that the

hardware is completely dry and free from contaminants before returning it to


service.

Device Capabilities
The following table and figure illustrate the voltage and the current source and sink ranges of
the NI 4138.
Table 1. Current Source and Sink Ranges
DC Voltage Ranges

DC Current Source and Sink Ranges

600 mV
6V
60 V

1 A
10 A
100 A
1 mA
10 mA
100 mA
1A
3A
Figure 1. Quadrant Diagram1
6.6 V, 3 A

Current (A)

2
20 V, 1 A

60 V, 0.33 A

0
1
2
3
60

50

40

30

20

10

10

20

30

40

50

60

Voltage (V)
Pulse or DC

DC sourcing power is limited to 20 W, regardless of output voltage.2

1
2

For information about configuring the NI 4138 for pulsing, refer to the NI DC Power Supplies and
SMUs Help.
Power limit defined by voltage measured at connector terminals.
NI PXIe-4138 Specifications |

National Instruments

| 3

Caution Limit DC power sinking to 12 W. Additional derating applies to sinking

power when operating at an ambient temperature of >45 C. If the PXI Express


chassis has multiple fan speed settings, ensure the fans are set to the highest setting.
Related Information
Sinking Power vs. Ambient Temperature Derating on page 5

Voltage Programming and Measurement


Accuracy/Resolution
Table 2. Voltage Programming and Measurement Accuracy/Resolution3
Range

Resolution
(Noise Limited)

Noise (0.1 Hz
to 10 Hz,
Peak to
Peak),
Typical

Accuracy (23 C
5 C) (% of
Voltage + Offset),
Tcal 5 C 4

600 mV 1 V

4 V

0.02% + 100 V

6V

10 V

12 V

0.02% + 600 V

60 V

100 V

120 V

0.02% + 6 mV

3
4
5

Temperature
Coefficient (% of
Voltage + Offset)/C,
0 C to 55 C

0.0005% + 1 V

When using remote sense, add 3 ppm of voltage range per volt of HI lead drop to voltage accuracy
specifications. Maximum 3 V drop per lead. Maximum 100 sense lead resistance.
Tcal is the internal device temperature recorded by the NI 4138 at the completion of the last selfcalibration.
Tcal is the internal device temperature recorded by the NI 4138 at the completion of the last selfcalibration.

ni.com

NI PXIe-4138 Specifications

Current Programming and Measurement


Accuracy/Resolution
Table 3. Current Programming and Measurement Accuracy/Resolution
Range

Resolution
Noise (0.1 Hz
Accuracy (23 C
(Noise Limited)
to 10 Hz,
5 C) (% of Current
Peak to
+ Offset), Tcal 5 C 5
Peak),
Typical

Temperature
Coefficient (% of
Current + Offset)/C,
0 C to 55 C

1 A

1 pA

8 pA

0.03% + 200 pA

0.0005% + 2 pA

10 A

10 pA

60 pA

0.03% + 1.4 nA

0.0005% + 20 pA

100 A 100 pA

400 pA

0.03% + 12 nA

0.0005% + 200 pA

1 mA

1 nA

4 nA

0.03% + 120 nA

0.0005% + 2 nA

10 mA

10 nA

40 nA

0.03% + 1.2 A

0.0005% + 20 nA

100 mA 100 nA

400 nA

0.03% + 12 A

0.0005% + 200 nA

1A

1 A

4 A

0.03% + 120 A

0.0005% + 2 A

3A

10 A

40 A

0.06% + 1.8 mA

0.0005% + 20 A

Noise, Typical
Wideband source noise
............................................................................
<20 mV peak-to-peak in 60 V range, normal
compensation, 10 Hz to 20 MHz

Sinking Power vs. Ambient Temperature


Derating
The following figure illustrates sinking power derating as a function of ambient temperature
for the NI 4138.

Tcal is the internal device temperature recorded by the NI 4138 at the completion of the last selfcalibration.
NI PXIe-4138 Specifications |

National Instruments

| 5

Figure 2. Sinking Power vs. Ambient Temperature Derating

Sinking Power (W)

13
12
11
10
9
8
7
6
5
4
3
2
1
0
0

5 10 15 20 25 30 35 40 45 50 55 60
Ambient Temperature (C)

Transient Response and Settling Time, Typical


Transient
............................................................................
response6
<70 s to recover within 0.1% of voltage range
after a load current change from 10% to 90%
of range, device configured for fast transient
response
Settling time7
<200 s
....................................................................
Voltage mode, 50 V step,
unloaded8
Voltage
....................................................................
mode, 5 V step or
<70 s
smaller, unloaded9
Current
....................................................................
mode, full-scale step,
<50 s
3 A to 100 A ranges10
Current
....................................................................
mode, full-scale step,
<150 s
10 A range10
Current
....................................................................
mode, full-scale step,
<300 s
1 A range10
The following figures illustrate the effect of the transient response setting on the step response
of the NI 4138 for different loads.
6
7
8
9
10

Current limit set to 1 mA and 10% of the selected current limit range.
Measured as the time to settle to within 0.1% of step amplitude, device configured for fast transient
response.
Current limit set to 50 A and 50% of the selected current limit range.
Current limit set to 20 A and 20% of selected current limit range.
Voltage limit set to 2 V, resistive load set to 1 V/selected current range.

ni.com

| NI PXIe-4138 Specifications

Figure 3. 1 mA Range No Load Step Response, Typical


1.1
1.0
0.9
Amplitude (Volts)

0.8
0.7
0.6

Slow, no load
Normal, no load
Fast, no load

0.5
0.4
0.3
0.2
0.1
0.0
0.1
0.0

20

40

60

80

100

Time (Microseconds)

Amplitude (Volts)

Figure 4. 1 mA Range, 100 nF Load Step Response, Typical


1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
0.1

Slow, 100 nF load


Normal, 100 nF load

0.0

0.4

0.8

1.2

1.6

2.0

Time (Milliseconds)

Load Regulation, Typical


Voltage
Device
....................................................................
configured for local
100 V per mA of output load change
sense
(measured between output channel terminals)
Device configured for remote
....................................................................
Load regulation effect included in voltage
sense
accuracy specifications

NI PXIe-4138 Specifications |

National Instruments

| 7

............................................................................
Current,
device configured for local
Load regulation effect included in current
or remote sense
accuracy specifications
Related Information
Voltage Programming and Measurement Accuracy/Resolution on page 4
Current Programming and Measurement Accuracy/Resolution on page 5

Measurement and Update Timing


Characteristics
Available
............................................................................
sample rates
(1.8 MS/s)/N where N = 1, 2, 3, 220
............................................................................
Sample rate accuracy
Equal to PXIe_CLK100 accuracy
............................................................................
Maximum measure rate to host
1.8 MS/s per channel, continuous
............................................................................
Maximum source update rate11
100,000 updates/s
Input trigger to
....................................................................
Source event delay
10 s
....................................................................
Source event jitter
1 s
....................................................................
Measure event jitter
1 s
Pulse timing and accuracy
....................................................................
Minimum pulse on time12
50 s
....................................................................
Minimum pulse off time13
50 s
....................................................................
Pulse on time or off time
100 ns
programming resolution
....................................................................
Pulse on time or off time
5 s
programming accuracy
....................................................................
Pulse on time or off time jitter
1 s

NI-DCPower Sequence Source Model


The following figure illustrates the programming flow in NI-DCPower using Sequence source
mode with automatic measurements.

11
12
13

8 |

As the source delay is adjusted, maximum source rates vary.


Pulse on time is measured from the start of the leading edge to the start of the trailing
edge.
Pulse off time is measured from the start of the trailing edge to the start of a subsequent
leading edge.

ni.com

| NI PXIe-4138 Specifications

Figure 5. NI-DCPower Programming Flow


Sequence
Loop
Count

Sequence

Num
Steps
Start
Trigger

Sequence
Advance
Trigger

Step
Source
Trigger

Source
Measure
Delay

Source

Source
Complete
Event

Measure
Complete
Event

Sequence
Iteration
Complete
Event

Sequence
Engine
Done
Event

Related Information
NI DC Power Supplies and SMUs Help

Absolute Maximum Limit Characteristics


............................................................................
Voltage between any two terminals
70 V
HI/LO current
............................................................................
3.5 A, DC only
Caution Applying levels beyond the ratings specified in this section can result in

permanent damage to the device.


Caution Connect only voltages that are within these limits.

Protection Characteristics
Output channel protection
Overcurrent or overvoltage
....................................................................
Automatic shutdown, output disconnect relay
opens
Overtemperature
....................................................................
Automatic shutdown, output disconnect relay
opens

NI PXIe-4138 Specifications |

National Instruments

| 9

Isolation Characteristics
Caution Do not connect to MAINs. Do not connect to signals or use for the
measurements within CAT II, III, or IV.

Isolation voltage, Channel-to-earth


150 VDC, CAT I, verified by dielectric
............................................................................
ground
withstand test, 5 s, continuous
Note Measurement Categories CAT I and CAT O (Other) are equivalent. These
test and measurement circuits are not intended for direct connection to the MAINs
building installations of Measurement Categories CAT II, CAT III, or CAT IV.
Caution Take precautions to avoid electrical shock when operating this product at

hazardous voltages.
Note Isolation voltage ratings apply to the voltage measured between any channel
pin and the chassis ground connector of the front panel. When operating channels in
series or floating on top of external voltage references, ensure that no terminal
exceeds this rating.

Guard Output Characteristics


Cable guard
Output impedance
....................................................................
2 k
....................................................................
Offset voltage
1 mV

Accessories
Table 4. NI 4138 Accessories
Accessory

Connector and Backshell Kit

Manufacturer

National Instruments

Related Information
Visit ni.com for more information about accessories

Calibration Interval
Recommended
............................................................................
calibration interval
1 year

10

ni.com

| NI PXIe-4138 Specifications

Part Number

156119A-01

Power Requirement Characteristics


PXI
............................................................................
Express power requirement
2.5 A from the 3.3 V rail and 2.2 A from the
12 V rail

Physical Characteristics
Dimensions
............................................................................
3U, one-slot, PXI Express/cPCI Express
module; 2.0 cm 13.0 cm 21.6 cm (0.8 in.
5.1 in. 8.5 in.)
Weight
............................................................................
419 g (14.8 oz)
Front panel connectors
............................................................................
5.08 mm (8 position)

NI PXIe-4138 Specifications |

National Instruments

| 11

Figure 6. Front Panel

NI PXIe-4138

System SMU

ACCESS

ACTIVE

OUTPUT
60 V
150 V

, 3 A MAX
MAX to

LO
SENSE
LO
GUARD
HI

GUARD

SENSE
HI

OUTPUT CAT I

Related Information
NI DC Power Supplies and SMUs Help

Environment
............................................................................
Maximum altitude
2,000 m (at 25 C ambient temperature)
............................................................................
Pollution Degree
2
Indoor use only.

12

ni.com

| NI PXIe-4138 Specifications

Operating Environment
............................................................................
Ambient
temperature range
0 C to 55 C (Tested in accordance with
IEC-60068-2-1 and IEC-60068-2-2.)
Relative humidity range
10% to 90%, noncondensing (Tested in
............................................................................
accordance with IEC-60068-2-56.)

Storage Environment
............................................................................
Ambient temperature range
-40 C to 70 C (Tested in accordance
with IEC-60068-2-1 and IEC-60068-2-2.)
............................................................................
Relative humidity range
5% to 95%, noncondensing (Tested in
accordance with IEC-60068-2-56.)
Operational shock
............................................................................
30 g peak, half-sine, 11 ms pulse (Tested in
accordance with IEC-60068-2-27. Test profile
developed in accordance with MILPRF-28800F.)
Random vibration
Operating
....................................................................
5 Hz to 500 Hz, 0.3 grms
Nonoperating
....................................................................
5 Hz to 500 Hz, 2.4 grms (Tested in accordance
with IEC-60068-2-64. Nonoperating test
profile exceeds the requirements of MILPRF-28800F, Class 3.)

Compliance and Certifications


Safety
This product is designed to meet the requirements of the following electrical equipment safety
standards for measurement, control, and laboratory use:

IEC 61010-1, EN 61010-1

UL 61010-1, CSA 61010-1


Note For UL and other safety certifications, refer to the product label or the Online
Product Certification section.

Electromagnetic Compatibility
This product meets the requirements of the following EMC standards for electrical equipment
for measurement, control, and laboratory use:
EN 61326-1 (IEC 61326-1): Class A emissions; Basic immunity

EN 55011 (CISPR 11): Group 1, Class A emissions


NI PXIe-4138 Specifications |

National Instruments

| 13

EN 55022 (CISPR 22): Class A emissions


EN 55024 (CISPR 24): Immunity
AS/NZS CISPR 11: Group 1, Class A emissions
AS/NZS CISPR 22: Class A emissions
FCC 47 CFR Part 15B: Class A emissions
ICES-001: Class A emissions
Note In the United States (per FCC 47 CFR), Class A equipment is intended for
use in commercial, light-industrial, and heavy-industrial locations. In Europe,
Canada, Australia, and New Zealand (per CISPR 11), Class A equipment is intended
for use only in heavy-industrial locations.
Note Group 1 equipment (per CISPR 11) is any industrial, scientific, or medical
equipment that does not intentionally generate radio frequency energy for the
treatment of material or inspection/analysis purposes.
Note For EMC declarations, certifications, and additional information, refer to the
Online Product Certification section.

CE Compliance
This product meets the essential requirements of applicable European Directives, as follows:

2006/95/EC; Low-Voltage Directive (safety)

2004/108/EC; Electromagnetic Compatibility Directive (EMC)

Online Product Certification


To obtain product certifications and the DoC for this product, visit ni.com/certification, search
by model number or product line, and click the appropriate link in the Certification column.

Environmental Management
NI is committed to designing and manufacturing products in an environmentally responsible
manner. NI recognizes that eliminating certain hazardous substances from our products is
beneficial not only to the environment but also to NI customers.
For additional environmental information, refer to the Minimize Our Environmental Impact
web page at ni.com/environment. This page contains the environmental regulations and
directives with which NI complies, as well as other environmental information not included in
this document.

Waste Electrical and Electronic Equipment (WEEE)


EU Customers At the end of the product life cycle, all products must be sent to a

WEEE recycling center. For more information about WEEE recycling centers,
National Instruments WEEE initiatives, and compliance with
WEEE Directive 2002/96/EC on Waste Electrical and Electronic Equipment, visit
ni.com/environment/weee.
14 |

ni.com |

NI PXIe-4138 Specifications

RoHS
National Instruments
(RoHS) National Instruments RoHS
ni.com/environment/rohs_china(For information about China RoHS
compliance, go to ni.com/environment/rohs_china.)

NI PXIe-4138 Specifications |

National Instruments

| 15

Refer to the NI Trademarks and Logo Guidelines at ni.com/trademarks for information on National Instruments trademarks.
Other product and company names mentioned herein are trademarks or trade names of their respective companies. For patents
covering National Instruments products/technology, refer to the appropriate location: HelpPatents in your software, the
patents.txt file on your media, or the National Instruments Patent Notice at ni.com/patents. You can find information about
end-user license agreements (EULAs) and third-party legal notices in the readme file for your NI product. Refer to the Export
Compliance Information at ni.com/legal/export-compliance for the National Instruments global trade compliance policy and
how to obtain relevant HTS codes, ECCNs, and other import/export data.
20132014 National Instruments. All rights reserved.
376114B-01

Feb14

NI PXIe-4138
SMU
NI PXIe-4138 NI 4138
SMU
NI 4138
ni.com/manuals
NI 4138
NI 4138

ni.com/manuals

EMC

I/O 3 m (10 ft)


235

30

24

niDCPower NIDCPOWER_ATTR_APERTURE_TIME
2 PLC

PXI Express

NI 4138
National InstrumentsNI-DCPower

..................................................................................................................................................3
............................................................................................................................................................3
/...................................................................................4
/...................................................................................4
.......................................................................................................................................................5
vs. .....................................................................................................................5
..............................................................................................................6
..................................................................................................................................................7
...................................................................................................................8
NI-DCPower .......................................................................................................8
..................................................................................................................................................9
......................................................................................................................................................................9
...................................................................................................................................................................10
....................................................................................................................................................10
..............................................................................................................................................................10
................................................................................................................................10
.........................................................................................................................................................11
...................................................................................................................................................................11
..............................................................................................................................................................................12
.........................................................................................................................................................13
.........................................................................................................................................................13
....................................................................................................................................................13
..............................................................................................................................................................13
....................................................................................................................................................14
CE .............................................................................................................................................14
................................................................................................................................14
.........................................................................................................................................................14

ni.com

| NI PXIe-4138

NI 4138
1. /
DC

DC /

1 A
10 A
100 A
1 mA
10 mA
100 mA
1A
3A

600 mV
6V
60 V

1. 1
6.6 V, 3 A

3
2

20 V, 1 A

(A)

60 V, 0.33 A

0
1
2
3
60

50

40

30

20

10

10

20

30

40

50

60

(V)
DC

DC 20 W 2

1
2

NI 4138
NI DC SMU

NI PXIe-4138 |

National Instruments

| 3

DC 12 W 45
PXI Express

vs. 5

/
2. / 3

0.1 Hz 23 5 %

10 Hz- % + / 055
Tcal5 4

600 mV 1 V

4 V

0.02% + 100 V

6V

10 V

12 V

0.02% + 600 V

60 V

100 V

120 V

0.02% + 6 mV

0.0005% + 1 V

/
3. /

0.1 Hz 23 5 %

10 Hz- % + / 0
Tcal 5 5

55

1 A

1 pA

8 pA

0.03% + 200 pA

0.0005% + 2 pA

10 A

10 pA

60 pA

0.03% + 1.4 nA

0.0005% + 20 pA

100 A 100 pA

400 pA

0.03% + 12 nA

0.0005% + 200 pA

1 mA

4 nA

0.03% + 120 nA

0.0005% + 2 nA

4
5

1 nA

1 V HI 3 ppm
3 V 100

Tcal NI 4138

Tcal NI 4138

ni.com

| NI PXIe-4138

3. /

10 mA

0.1 Hz 23 5 %

10 Hz- % + / 0
Tcal 5 5

55

10 nA

100 mA 100 nA

40 nA

0.03% + 1.2 A

0.0005% + 20 nA

400 nA

0.03% + 12 A

0.0005% + 200 nA

1A

1 A

4 A

0.03% + 120 A

0.0005% + 2 A

3A

10 A

40 A

0.06% + 1.8 mA

0.0005% + 20 A

................................................................................................60 V 20 mV -

10 Hz20 MHz

vs.
NI 4138

2. vs.

(W)

13
12
11
10
9
8
7
6
5
4
3
2
1
0
0

5 10 15 20 25 30 35 40 45 50 55 60
(C)

Tcal NI 4138

NI PXIe-4138 |

National Instruments

| 5


................................................................................................
6
70 s 10%
90% 0.1%

7
......................................................................................
50 V
200 s
8
......................................................................................
5 V
70 s

9
......................................................................................

50 s
3 A100 A
10
......................................................................................

150 s
10 A 10
......................................................................................

300 s
1 A 10
NI 4138

6
7
8
9
10

1 mA 10%

0.1%
50 A 50%

20 A 20%

2 V 1 V/

ni.com

NI PXIe-4138

3. 1 mA
1.1
1.0
0.9
0.8
(V)

0.7
0.6

0.5
0.4
0.3
0.2
0.1
0.0
0.1
0.0

20

40

60

80

100

(V)

4. 1 mA 100 nF
1.3
1.2
1.1
1.0
0.9
0.8
0.7
0.6
0.5
0.4
0.3
0.2
0.1
0.0
0.1

100 nF
100 nF

0.0

0.4

0.8

1.2

1.6

2.0

......................................................................................1 mA 100 V

......................................................................................

NI PXIe-4138 |

National Instruments

| 7

................................................................................................

/ 4
/ 4

................................................................................................

1.8 MS/s/NN = 1, 2, 3, 220


................................................................................................

PXIe_CLK100
................................................................................................

1.8 MS/s
................................................................................................
11
100,000 /s

......................................................................................
10 s

......................................................................................
1 s

......................................................................................
1 s

......................................................................................
50 s
ON 12
......................................................................................
50 s

OFF 13
......................................................................................
100 ns

ON OFF

......................................................................................
5 s
ON OFF

......................................................................................
1 s
ON OFF

NI-DCPower
NI-DCPower

11
12
13

ON

OFF

ni.com

NI PXIe-4138

5. NI-DCPower

NI DC SMU

................................................................................................
70 V
2
................................................................................................
HI/LO

3.5 ADC

......................................................................................

......................................................................................

NI PXIe-4138 |

National Instruments

| 9


CAT IIIII IV

................................................................................................150 VDCCAT I5
/

Measurement Category CAT I CAT O (Other)


Measurement Category CAT IICAT IIICAT
IV MAINS

......................................................................................
2 k

......................................................................................
1 mV

4. NI 4138

National Instruments

ni.com

................................................................................................

1
10

ni.com

NI PXIe-4138

156119A-01


................................................................................................
PXI Express
3.3 V 2.5 A12 V
2.2 A

................................................................................................

3U1 PXI Express/cPCI Express


2.0 x 13.0 x 21.6 cm0.8 x 5.1 x
8.5 in.
................................................................................................419 g14.8 oz

................................................................................................

5.08 mm8

NI PXIe-4138 |

National Instruments

| 11

6.

NI PXIe-4138

System SMU

ACCESS

ACTIVE

OUTPUT
60 V
150 V

, 3 A MAX
MAX to

LO
SENSE
LO
GUARD
HI

GUARD

SENSE
HI

OUTPUT CAT I

NI DC SMU

................................................................................................2,000 m 25

................................................................................................
2

12

ni.com

NI PXIe-4138


................................................................................................055IEC-60068-2-1

IEC-60068-2-2

................................................................................................

1090IEC-60068-2-56

................................................................................................

-4070IEC-60068-2-1
IEC-60068-2-2

................................................................................................

595IEC-60068-2-56

................................................................................................

30 g
11 ms
IEC-60068-2-27 MILPRF-28800F

......................................................................................

5500 Hz0.3 grms


......................................................................................

5500 Hz2.4 grmsIEC-60068-2-64

MIL-PRF-28800FClass 3

IEC 61010-1EN 61010-1

UL 61010-1CSA 61010-1
UL

NI PXIe-4138 |

National Instruments

| 13


EMC

EN 61326-1 (IEC-61326-1): Class A

EN 55011 (CISPR 11): Group 1Class A

EN 55022 (CISPR 22): Class A

EN 55024 (CISPR 24):

AS/NZS CISPR 11: Group 1Class A

AS/NZS CISPR 22: Class A

FCC 47 CFR Part 15B: Class A

ICES-001: Class A
FCC 47 CFR
Class A

CISPR 11 Class A

Group 1 CISPR 11 /

EMC

CE
EC

2006/95/EC

2004/108/ECEMC

ni.com/certification

NI NI

14

ni.com |

NI PXIe-4138

ni.com/environment Minimize Our


Environmental Impact

WEEE
WEEE

WEEE
WEEE
WEEE 2002/96/EC ni.com/environment/weee

RoHS
National Instruments
(RoHS) National Instruments RoHS
ni.com/environment/rohs_china(For information about China RoHS
compliance, go to ni.com/environment/rohs_china.)

NI PXIe-4138 |

National Instruments

| 15

National Instruments ni.com/trademarks NI Trademarks and Logo Guidelines


National Instruments
/
patents.txt ni.com/patents National Instruments Patent Notice()
EULA NI
Readme HTS
ECCN/

ni.com/
legal/export-compliance
20132014 National Instruments. All rights reserved.
376114B-01

2014 02

Anda mungkin juga menyukai