Anda di halaman 1dari 8

N

O
I
T

WATER LOOP

A
S
I
M
I
T
P

O
E

WATERSOLUTIONS

Heat pumps & Water chillers from 5 to 1350 kW

THE ULTIMATE IN
ENERGY SOLUTIONS

NA 13.80 A

Heat pumps & Water chillers

a unique European
range
With over 50 ranges, CIAT's heat pump and water
chiller offer is one of the best on the international
market.
With low, medium or high capacity
models,
from

professionals

can

comprehensive

choose

range

of

heating and cooling technologies: aircooled

condensation,

water-cooled

condensation, production of hot or


cold water and heat recovery units.
Smart control systems, ready to install
"plug and cool" models, and even High
Energy Efficiency versions complete this
exceptional offer.
CIAT meets the needs of those involved
in specification and installation in
the residential, tertiary, healthcare or
industry sectors.
This

vast

guarantees

range
your

of

solutions

CIAT

partners

remain completely objective in the choice


of equipment required faced with technical,
geographical and economic criteria for new or
renovated buildings.

CIAT heat pumps and water chillers are


manufactured in modern industrial plants with
ISO 9001, ISO 14001 and OHSAS 18001 certifications.

CIAT system package


compatibility across the line
To comply more effectively with thermal and environmental regulations, CIAT proposes systems on the
water loop, the best fluid for transferring heat.
CIAT solutions are as powerful as they are simple to use and users are guaranteed controlled comfort.

Chiller
Powerciat2*

Heat pump
Aquaciat Power

Comfort unit
Major Line
CIATControl*

Exchanger
Itex*

Energy pool control


PowerControl*

Energy storage
Cristopia*

Comfort unit
Coadis Line

Air handling unit


Climaciat Airtop / Airtech

CIAT participates in the


EUROVENT UC-AHU-LCP-RT
certification programmes.
Check the validity of the certicate:
www.eurovent-certication.com or
www.certiash.com
except for models marked with *

WATER-TO-WATER
Ageo+

Dynaciat

6 to 30 kW

35 to 180 kW

LG
ILG
LGN*

Ageo CALEO *
16 to 25 kW

G-Kub*

7 to 13 kW

Dynaciat POWER
Hydrociat

220 to 720 kW

LG
LGN*

370 to 1170 kW

LW

AIR-TO-WATER

CENTRIFUGAL UNITS

Ciatcooler Standard
17 to 200 kW

Ciatcooler High Efficiency


18 to 160 kW

LP
ILP

C
C
Ecociat*

10 to 30 kW

EQUIPMENT AND VERSIONS AVAILABLE


COOLING
HEAT

ONLY VERSION

PUMP VERSION

REVERSIBLE

VERSION

HEAT RECOVERY

DOMESTIC

HIGH

HYDRAULIC

TEMPERATURE

FREE-COOLING

HOT WATER

MODULE VERSION

VERSION WITHOUT CONDENSER

SCROLL
SCREW

COMPRESSOR

COMPRESSOR

MISTING

AIR-TO-WATER

AXIAL UNITS

Aqualis 2+

Aqualis CALEO*

6 to 19 kW

13 kW

Aquaciat GRAND INVERTER


41 to 53 kW

Aquaciat CALEO*

IVDC

25 to 50 kW

TDC

Aquaciat2 EVOLUTION LD
20 to 170 kW
ILD

C-H
C-H

Aquaciat POWER Standard

Powerciat2 Standard*

Aquaciat

Powerciat2 High Efficiency*

190 to 640 kW

POWER

High Efficiency

190 to 657 kW

LD
ILD

C-H
C-H

667 to 1,356 kW
600 to 1,153 kW

LX

DRYCOOLERS
AIR-COOLED CONDENSERS

Opera*

10 to 1000 kW

Vextra*

up to 2000 kW

EXCHANGERS
Exel*

from 2 to 200 kW

Itex*

from 5 to 5,000 kW

Corelis*

from 100 to 4,000 kW

SYSTEM CONTROL
Easy CIATControl: optimum control of Hysys system solutions for
offices, hotels and residential care homes.
Smart CIATControl: optimised maintenance and energy performance of
Hysys system solutions made easy, on site or remotely.
Easy CIATControl

PowerControl

PowerControl and CristoControl2 : Global management system for high


performance thermal energy production pools providing heating and
cooling. Both offers automatically manage operating modes and control the
thermal system by monitoring all of the thermal production components:
chillers and heat pumps, dry coolers, valves, pumps, etc.
CristoControl2 optimises energy storage through various scenarii,
depending on the use of the unit and energy costs.

Smart CIATControl

CristoControl2

WATER CHILLERS AND HEAT PUMPS


AIR-COOLED CONDENSATION
AXIAL air-to-water heat pumps
AXIAL UNITS (cooling only)
Size
35 T
50 T
65 T
75 T
Size
80 V
90 V
100 V
120 V
150 V
180 V
200 V
240 V
300 V
350 V
400 V
500 V
540 V
600 V
700 V
Size
702 V
800 V
900 V
1000 V
1100 V
1200 V
1400 V
1600 V
1800 V
2000 V
2100 V
2400 V

AQUALIS 2+
Power R410A(kW)
Dimensions (mm)
Cc
8.5
11.8
14.7
17.5

Pi
3.7
4.4
5.0
6.4

length
1035
1035
1035
1035

width
350
350
350
350

Weight
height (kg)
657.4
1257
1257
1257

82
120
145
140

AQUACIAT2 LD-LDC-LDH
R410A(kW)
Dimensions (mm)
Cc
20.5
23.4
27.3
30.4
38.2
46.2
53.2
60.1
75.7
92.0
100.8
125.7
141.1
154.2
170.5

Pi
6.7
7.7
8.7
10.1
13.9
14.8
17.7
20.4
28.1
30.2
35.0
43.2
46.3
53.7
63.0

length
1995
1995
1995
1995
1995
1995
1995
1995
1995
2190
2190
2190
2740
2740
2740

width
1055
1055
1055
1055
1055
1055
1055
1055
1055
1055
1055
1055
1055
1055
1055

Weight
height (kg)
1170
1170
1393
1393
1393
1743
1743
1743
1743
2117
2117
2117
2117
2117
2117

AQUACIATPOWER LD-LDC-LDH STANDARD


R410A(kW)
Dimensions (mm)
Cc
188
210
245
268
289
333
379
437
491
532
568
640

Pi
61.5
71.2
82.8
91.9
102.7
111.7
128.7
146.8
164.6
178.6
192.8
216

length
2820
2820
2820
2820
2820
4185
4185
5551
5551
6913
6913
6913

width
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200
2200

height
2260
2260
2260
2260
2260
2260
2260
2260
2260
2260
2260
2260

347
350
365
367
449
569
575
581
711
1064
1163
1245
1530
1666
1732

Weight
(kg)
2330
2395
2550
2730
2800
3225
3482
3929
4605
5090
5282
5603

AQUACIATPOWER LD-LDC-LDH HEE


Size
702 V
800 V
900 V
1000 V
1100 V
1200 V
1400 V
1600 V
1800 V
2000 V
2100 V
2400 V

R410A(kW)
Cc
Pi
192
60.4
218
70
261
82.6
281
90.6
310
98
345
110
396
124
447
143
516
163
566
180
587
187
665
211

Dimensions (mm)
Weight
(kg)
length width height
2820
2200
2260
2415
2820
2200
2260
2500
4185
2200
2260
2840
4185
2200
2260
3000
4185
2200
2260
3285
4185
2200
2260
3482
5551
2200
2260
4113
6913
2200
2260
4545
6913
2200
2260
5310
6913
2200
2260
5415
8284
2200
2260
6008
8284
2200
2260
6116

Size
20 H
28 H
35 H(T)
50 H(T)
65 HT
75 HT
Size
60 H
60 HT
Size
80 Z
100 Z
120 Z
150 Z
Size
80 V
90 V
100 V
120 V
150 V
180 V
200 V
240 V
300 V
350 V
400 V
500 V
540 V
600 V
700 V
Size
702 V
800 V
900 V
1000 V
1100 V
1200 V
1500 V
1650 V
1800 V

2800 X
3000 X
3200 X
3400 X
3600 X
4200 X
4800 X
5400 X
6400 X

R134a (kW)
Cc

Pi

667
723
792
840
891
1049
1156
1269
1355

227
250
266
282
299
345
390
426
470

Dimensions (mm)
Weight
length
(kg)
width height
LX LXC
6506 7596 2251
2436
5196
6506 7596 2251
2436
5612
7592 8682 2251
2436
6558
7592 8682 2251
2436
6591
7592 8682 2251
2436
6618
9756 10846 2251
2436
7843
9756 10846 2251
2436
7867
11928 13108 2251
2436
9334
11928 13108 2251
2436
9508

POWERCIAT2 LX - LXC HEE*


Size
2500X
2800X
3050X
3200X
3400X
3600X
3900X
4200X
4500X
4800X

R134a (kW)
Cc

Pi

617
684
762
825
879
927
989
1072
1126
1171

199
220
244
259
273
286
312
334
354
371

Dimensions (mm)
Weight
length
(kg)
width height
LX LXC
6506 7596 2251
2436
5159
7592 8682 2251
2436
5731
7592 8682 2251
2436
6166
9756 10846 2251
2436
7782
9756 10846 2251
2436
7795
9756 10846 2251
2436
7813
9756 10846 2251
2436
7900
11928 13018 2251
2436
9123
11928 13018 2251
2436
9136
11928 13018 2251
2436
9148

CENTRIFUGAL cooling only


Size
90 V
100 V
120 V
160 V
180 V
200 V
240 V
280 V
320 V
360 V
Size

CIATCOOLER LP-LPC STANDARD


Power R410A(kW)
Dimensions (mm)
Cc
17.7
21.1
25.2
32.7
36.0
43.7
49.3
55.7
68.0
74.3

Pi
7.8
9.1
10.0
12.4
14.3
17.5
19.7
22.2
24.6
28.4

length
1117
1117
1398
1398
1398
2113
2673
2673
2673
2673

width
860
860
860
860
860
860
860
860
860
860

Weight
height (kg)
1437
1437
1717
1717
1717
1437
1717
1717
1717
1717

CIATCOOLER LP-LPC HEE


Power R410A(kW)
Dimensions (mm)

Cc
Pi
length width height
18.9
7.4
1117
860
1437
90 V
23.2
8.8
1398
860
1717
100 V
27.0
9.7
1398
860
1717
120 V
33.3
11.9
2113
860
1437
160 V
36.9
13.3
2113
860
1437
180 V
46.4
17.4
2673
860
1717
200 V
55.2
19.2
2673
860
1717
240 V
62.2
22.2
2673
860
1717
280 V
Chilled water outlet temperature +7C - Air inlet temperature +35C
Weights and dimensions of standard versions
Cc. Net cooling capacity
Pi Net input power
* Equipment not part of EUROVENT certification programmes

297
310
369
387
385
558
638
670
704
710

Weight
(kg)
294
351
368
450
455
633
656
662

AQUALIS 2+
R410A(kW)
Dimensions (mm)
Cc
5.3
7.1
8.5
11.8
14.7
17.5

Hc
6.1
8.3
10.2
13.8
17.2
19.4

length
1035
1035
1035
1035
1035
1035

width
350
350
350
350
350
350

Weight
height (kg)
657.4
657.4
1257
1257
1257
1257

AQUALIS CALEO*
R407C(kW)
Dimensions (mm)
Hc
13.7
13.7

Pi
3.8
3.3

length
1035
1035

width
350
350

height
1257
1257

AQUACIAT CALEO TDC*


R407C kW
Dimensions (mm)
Hc
24.8
34.7
40.8
47.3

Pi
6.8
9.2
10.4
12.4

length
1995
1995
1995
1995

width
1055
1055
1055
1055

height
1423
1423
1423
1423

73
79
120
120
145
140

Weight
(kg)
126
126

Weight
(kg)
398
465
482
497

AQUACIAT 2 ILD-ILDC-ILDH
R410A kW
Dimensions (mm)
Cc
20.1
22.7
27.2
30.3
40.2
46.8
53.2
61.5
75.3
92.4
104.8
127.5
139.2
154.7
162.4

Hc
20.8
23.4
28.3
31.9
41.7
48.7
55.3
64.1
81.8
95.4
109.3
133.2
147.8
164.7
182.4

length
1995
1995
1995
1995
1995
1995
1995
1995
1995
2190
2190
2190
2740
2740
2740

width
1055
1055
1055
1055
1055
1055
1055
1055
1055
2129
2129
2129
2129
2129
2129

Weight
height (kg)
1170
1170
1393
1393
1393
1743
1743
1743
1743
2117
2117
2117
2117
2117
2117

328
331
366
368
452
611
614
620
756
1096
1195
1283
1570
1706
1878

AQUACIATPOWER ILD-ILDC-ILDH
R410A (kW)
Dimensions (mm)
Cc
183
201
239
257
278
332
381
434
486

Hc
192
214
249
266
287
342
389
452
505

length
2820
2820
2820
2820
2820
4185
4185
5551
5551

width
2200
2200
2200
2200
2200
2200
2200
2200
2200

Weight
height (kg)
2260
2260
2260
2260
2260
2260
2260
2260
2260

2535
2595
2600
2765
2850
3575
4033
4648
4707

CENTRIFUGAL air-to-water heat pumps

POWERCIAT2 LX - LXC STANDARD*


Size

WATER-COOLED CONDENSATION

Size
90 V
100 V
120 V
160 V
180 V
200 V
240 V
280 V
320 V
360 V
Size
90 V
100 V
120 V
160 V
180 V
200 V
240 V
280 V

CIATCOOLER ILP-ILPC STANDARD


R410A (kW)
Dimensions (mm)
Cc
17.7
21.1
25.2
32.7
36.0
43.7
49.3
55.7
68.0
74.3

Hc
21.8
26.1
29.7
38.3
42.6
51.6
58.7
66.9
76.5
84.8

length
1117
1117
1398
1398
1398
2113
2673
2673
2673
2673

width
860
860
860
860
860
860
860
860
860
860

height
1437
1437
1717
1717
1717
1437
1717
1717
1717
1717

Weight
(kg)
297
310
369
387
385
558
638
670
704
710

CIATCOOLER ILP-ILPC HEE


R410A (kW)
Dimensions (mm)
Cc
18.9
23.2
27.0
33.3
36.9
46.4
55.2
62.2

Hc
22.5
27.1
31.1
39.6
44.1
54.4
60.6
69.3

length
1117
1398
1398
2113
2113
2673
2673
2673

width
860
860
860
860
860
860
860
860

Weight
height (kg)
1437
1717
1717
1437
1437
1717
1717
1717

294
351
368
450
455
633
656
662

EXTRACTED AIR/WATER HEAT RECOVERY UNIT


Size
30 V
50 V
90 V

Air flow
(m3/h)
2000
3500
5500

ECOCIAT*
R410A (kW)
Dimensions (mm)
Hc
10.3
18
31.7

Pi
2.9
5
9.1

length
2227
2227
2227

width
1185
1185
1185

height
965
965
965

Cooling: water outlet +7C/air +35C


Heating: water outlet +45C/air +7C WB
Cc. Net cooling capacity
Pi Net input power
Hc. Net heating capacity
* Equipment not part of EUROVENT certification programmes

Weight
(kg)
338
363
400

Size
20 H
33 H
45 H
45 HT
Size
20 H
30 H
40 H
40 HT
50 H
50 HT
65 HT
80 HT
100 HT
120 HT

Size
50 H
50 HT
65 HT
80 HT
Size
120 V
150 V
200 V
240 V
300 V
Size
120 V
150 V
200 V
240 V
300 V
350 V
400 V
500 V
540 V
600 V
Size
700 V
800 V
900 V
1000 V
1100 V
1200 V
1400 V
1600 V
1800 V
2100 V
2400 V

R410A (kW)
Hc
7.4
9.6
13.1
13.2

G-KUB*
Dimensions (mm)

Pi
1.3
1.6
2.3
2.14

R410A(kW)
Hc
7.4
9.4
11.5
11.3
15.3
16.1
19.8
24.5
30.9
36.3

length
685
685
685
685

width
760
760
760
760

height
1035
1035
1035
1035

AGEO+
Dimensions (mm)

Pi
1.5
1.9
2.3
2.2
3.1
3.2
3.9
4.7
5.7
7.1

length
650
650
650
650
650
650
650
650
650
650

width
695
695
695
695
695
695
695
695
695
695

height
1230
1230
1230
1230
1230
1230
1230
1230
1230
1230

AGEO CALEO*
R410A(kW)
Dimensions (mm)
Hc
16.6
17.4
20.6
25.2

Pi
3.2
3.5
4.1
5.0

length
650
650
650
650

width
695
695
695
695

height
1230
1230
1230
1230

DYNACIAT ILG
R410A(kW)
Dimensions (mm)
Cc
28.9
37.6
50.3
58.8
76.6

Hc
38.1
49.9
66.6
76.8
100

length
798
798
1492
1492
1492

width
883
883
883
883
883

height
1201
1201
1201
1201
1201

DYNACIAT LG
R410A(kW)
Dimensions (mm)
Cc

Pi

Weight
(kg)
146
161
161
159

Weight
(kg)
133
135
139
139
154
154
164
168
190
195

Weight
(kg)
151
151
161
165

Weight
(kg)
226
289
379
452
595

length

width

height

Weight
(kg)
230

34.5

8.0

798

883

1201

45.3

10.3

798

883

1201

300

61.1

13.9

1492

883

1201

385

68.6

16.2

1492

883

1201

390

90.9

20.3

1492

883

1201

590

104.7

23.6

1492

883

1201

620

118.9

26.9

1492

883

1201

665

146.5

33.8

1492

883

1201

735

158.9

36.1

2380

883

1201

930

181.9

40.1

2380

883

1201

1125

DYNACIATPower LG
R410A(kW)
Dimensions (mm)
Cc

Pi

length

width

height

Weight
(kg)

217

48.2

2099

996

1869

1044

251

55.2

2099

996

1869

1156

288

64.2

2099

996

1869

1189

327

73.0

2099

996

1869

1312

356

79.2

2099

996

1869

1363

385

85.6

2499

996

1887

1425

443

97.4

2499

996

1887

1613

499

110.4

3350

996

1970

1708

582

125

3350

996

1970

2284

657

146

3350

996

1970

2376

713

168

3350

996

1970

2418

HYDROCIAT LW
Size
1800 BX
1800 BX HPS
2150 BX
2150 BX HPS
2500 BX
2500 BX HPS
2800 BX
2800 BX HPS
3050 BX HPS
3500 BX HPS
3600 BX HPS
3900 BX HPS
4200 BX HPS
4500 BX HPS
4800 BX HPS

R134a (kW)
Cc
417
432
490
531
585
622
657
688
811
918
953
1040
1075
1129
1164

Pi
95
98
113
118
130
139
145
152
170
198
201
221
229
248
258

Dimensions (mm)
length
3800
3800
4700
4700
4700
4700
4700
4700
4538
4567
4538
4567
4567
4567
4567

width
1320
1320
1320
1320
1320
1320
1320
1320
1500
1500
1500
1500
1500
1500
1500

height**
1860
1860
1970
1970
1970
1970
1970
1970
1895
1895
1895
1895
1895
1895
1895

Chilled water outlet temperature +7c


Cooling water outlet temperature +35C
Cc. Net cooling capacity
Pi Net input power
Hc. Net heating capacity
* Equipment not part of EUROVENT certification programmes
** Low-profile version

Weight
(kg)
3130
3150
3520
3540
3830
3850
3840
3860
4691
4759
5106
5274
5293
5342
5362

With over 80 years' experience,


more than 2,000 employees,
and 6 production sites
including a vast industrial
complex in the Rhne-Alpes
region, CIAT has obtained
ISO 14001 certification and is
renowned as a major player in
the HVAC industry.

The CIAT Group: European leader

in heating, cooling and indoor air quality

END OF LIFE

MAINTENANCE

USE

RAW
MATERIAL

TRANSPORT

An environmentally-responsible company
working towards a greener world
For many years, CIAT has been pursuing an industrial policy based
on an ongoing strategy of continued sustainable development
and eco-design in order to minimise the environmental impact
of its equipment. The equipment integrated into Hysys system
solutions benefits from this commitment.

DESIGN
MANUFACTURE

A Group resolutely focused on innovation


CIAT's Centre for Research and Innovation, one of the largest
in Europe, brings engineers and technicians together around
a simulation platform dedicated to well-being. As a team,
they constantly improve the comfort, Indoor Air Quality and
energy performance levels of CIAT solutions to meet the
requirements of consumer sectors.

An exclusive network of advisers

Industry

Offices

Healthcare

Hotels

Shopping Centres

Administration
Education

To ensure customer satisfaction, at CIAT we have organised our teams into seven centres of expertise.
Operating in France and throughout Europe, our experts listen to your needs and, because they speak your
language, they provide you with the best solution to meet your requirements.

www.ciat.com

Residential

Anda mungkin juga menyukai