Anda di halaman 1dari 1

CHANGING ANGEL EYE VOLTAGE

1. Start NCSExpert & Load FSW PSW MAN profile.


2. Press F1 then F3 and select E89 then select CAS
3. Press F6 then F4. From the modules listed select NFRM
4. Under the word 'JOBNAME' on NCSExpert you will now have something which starts
FRM3_E89....................................... Note all this down as you will need it later.
5. Press F4 (read ECU). A box title NETTODAT.TRC will now open - you can close this.
6. You can now close NCSExpert
7. The above should have saved you a NETTODAT.TRC file in your NCSExpert Work folder. You are now going to
change this file using NCSDummy.
8. Open NCSDummy - if it is the first time you have used it specify the path to your NCSExpert DATEN folder
9. In NCS Dummy select the following: Chassis - E89. Module - FRM3_E89.C32. FSW/PSW or Nettodata trace - the
NETTODAT.TRC file you created above.
10. If you have done this correctly a new Tab appears labelled Trace Editor. Select this.
11. You now need to amend two entries: PWM_SL_1_FKT_BL_TFL & PWM_SL_1_FKT_SL_TFL. The entries are in
alphabetical order so are easy to find.
12. For the first one mine had options wert 1 to 9 available with wert 3, 6 & 9 selected. In the second one wert 1 to
11 was available with 3, 4 & 10 selected. If you click on any of the selected ones the part you are interested in is
listed as Data in the details section (this is what sepcifies the voltage)
13. On mine the BL showed Data of 0A,D7 and the SL showed Data of 06,66.
14. To override these if you right click on one of the selected entries you are given the option to add new custom
parameters. The new custom parameter will be given the name <benutzerdefinierte> - <custom>.
15. Once added, click the box to the left to select it and this should deselect the previous 'factory' selected options
16. The Data option in details below should show as 00,00 and you can change this to any allowable entry. If you use
0C,2C you are specifying 13.7 volts . You will need to search if you need other voltages
17. Make sure this is done for both the BL and SL entries
18. Once completed click Editor Functions and Export Nettodata Trace File. You should now be able to save a
NETTODAT.MAN file.
19. You can now close NCSDummy as we have just created a new MAN file which we are going to use to code the
NRFM module.
20. Start NCSExpert & Load Revtor's NCE Expert Profile
21. Press F1 then F3 and select E89 the select CAS
22. Press F6 then F4. From the modules listed select NFRM
23. A popup window will now open and check the details to those listed in point 4. DO NOT GO ANY FURTHER IF
THEY DO NOT MATCH AS YOU HAVE DONE SOMETHING WRONG.
24. Assuming above is OK click OK and press F5 (basic functions). In the popup window select
coapiCodeSgByNettoData.
25. For the CBD name make sure the correct module is already set & for Nettodatenliste enter NETTODAT.MAN (the
file you created above)
26. Click OK to start the coding job

Anda mungkin juga menyukai