Anda di halaman 1dari 3

RNC1> get 0

140811-11:39:47 10.215.0.33 9.0u RNC_NODE_MODEL_V_2_2497 stopfile=/tmp/25680


================================================================================
=================================
0
ManagedElement=1
================================================================================
=================================
ManagedElementId
1
applicationConfiguration
t[0] =
faultTolerantCoreStates
s[2] = ManagedElement=1,Equipment=1,Subrack
=MS,Slot=10,PlugInUnit=1;ftcState=PassiveReady ManagedElement=1,Equipment=1,Subr
ack=MS,Slot=11,PlugInUnit=1;ftcState=Active
healthCheckResult
Struct{3}
>>> 1.healthCheckResultCode = 1 (NOT_OK)
>>> 2.message =
>>> 3.startTime = 2014-08-11 09:35
healthCheckSchedule
t[1] =
>>> Struct[0] has 2 members:
>>> 1.time = 04:00
>>> 2.weekday = 1 (SUNDAY)
logicalName
RNC
mimInfo
Struct{3}
>>> 1.mimName = RNC_NODE_MODEL_V
>>> 2.mimVersion = 2.2497
>>> 3.mimRelease =
productName
RNC3810
productNumber
productRevision
productType
Node
site
RNc
userLabel
RNC
================================================================================
=================================
Total: 1 MOs

RNC> alt
140811-11:13:10 10.215.0.33 9.0u RNC_NODE_MODEL_V_2_2497 stopfile=/tmp/28622
Connecting to 10.215.0.33:56834 (CorbaSecurity=OFF, corba_class=2, java=1.6.0_29
, jacoms=R73D26, jacorb=R73D01)
Trying file=/var/opt/ericsson/amos/moshell_logfiles/t140625/logs_moshell/tempfil
es/20140811-110203_28345/ior28345
Resolving the alarm service in OMS...
Simple Alarm Client initialized...
Starting to retrieve active alarms
Nr of active alarms are: 2
================================================================================
====================================
Date & Time (Local) S Specific Problem
MO (Cause/AdditionalIn
fo)
================================================================================
====================================
2014-08-10 06:02:49 M Upgrade Package Corrupt
UpgradePackage=CXP9021
776/1_R3EA11 (file_error)
2014-08-11 11:11:40 M File System Diagnostic Error
Subrack=ES-3,Slot=14,P
lugInUnit=1 (disk_problem)

>>> Total: 2 Alarms (0 Critical, 2 Major)

RNC> alt
140817-15:03:32 10.210.0.33 9.0u RNC_NODE_MODEL_N_1_380 stopfile=/tmp/4287
Connecting to 10.210.0.33:56834 (CorbaSecurity=OFF, corba_class=2, java=1.6.0_29
, jacoms=R73D25, jacorb=R73D01)
Trying file=/var/opt/ericsson/amos/moshell_logfiles/t140625/logs_moshell/tempfil
es/20140817-150157_4233/ior4233
Resolving the alarm service in OMS...
Simple Alarm Client initialized...
Starting to retrieve active alarms
Nr of active alarms are: 1
================================================================================
====================================
Date & Time (Local) S Specific Problem
MO (Cause/AdditionalIn
fo)
================================================================================
====================================
2014-08-17 06:00:12 M File System Diagnostic Error
Subrack=ES-3,Slot=16,P
lugInUnit=1 (Message: Result: /d ok, /p nok)
>>> Total: 1 Alarms (0 Critical, 1 Major)

PROCEDIMIENTO DE RECUPERACIN DE LAS TARJETAS (NO MP):


1.
Mediante AMOS, bloquear la tarjeta XXYY00 (por ejemplo, 001800) por com
ando:
bl 001800
2.
Conectarse a la RNC mediante telnet <direccin IP RNC>:
telnet 10.210.0.33
3.
Conectarse a la tarjeta en fallo (telnet):
$ lhsh 001800
Welcome to OSE Shell OSE5.5.
001800>
En este momento, estamos conectados a la tarjeta:
4.
Conectado a la tarjeta, formatear los volmenes en fallo de la tarjeta en
fallo (formath /d y formath /pXXYY00):
001800> formathd /d
001800> formathd /p001800
5.
Desde AMOS. Reiniciar la tarjeta (cold con HW test)
acc 001800 manualrestart
Rank: RESTART_COLDWTEST
Restart reason: UNPLANNED_COLD_WITH_HW_TEST )
Restart information: File System Diagnostic Error
6.
Desde AMOS. Desbloquear la tarjeta si queda bloqueada.
deb 001800
7.
Correr de Nuevo el health check en el MO ManagedElement=1, usando la ac
cin startHealthCheck.
8.
Esperar al fin del proceso unos minutos y comprobar el resultado observa
do el healthCheckResultCode dentro del atributo healthCheckResult.

9.
Verificar si las alarmas han desparecido.
10.
En caso de que no desparezcan las alarmas, crear incidencia para cambiar
la GPB en fallo