Anda di halaman 1dari 1

Anwar Hassan

Exercise
Comments MODERATED MARKS
Limited improvement on previous submission
No single model file submitted comments based upon
2d
Xrefd file creating the drawing sheet file
AutoCAD bound
Anwar Hasan- 18040046- CAD Studio 2A -Assignment
1-British Pavillion
Created:
10 December 2012 19:42:18:976
Last updated:
27 August 2014 14:54:15:541
Total editing time: 9 days 19:36:56:887
48 LAYERS 1558 OBJECTS

Mark
No submission via e-mail files from Submitted CD
Anwar Hasan- 18040046- CAD Studio 2A -Assignment 1British Pavillion
Created:
10 December 2012 19:42:18:976
Last updated:
27 August 2014 14:54:15:541
Total editing time: 9 days 19:36:56:887

11/50

LAYERING

1/10

Elements incorrectly on LAYER 0 [-1]


Graphical elements incorrectly on dimension layers ie A271D5 [-1]
Minimal layering demonstrated [-1]
Incorrect level of detail filters set up [-2] 1:10 = ?????2*,*|?????2* 1:50= ?????4*,*|?????4* 1:100=?????5*,*|?????5
Ideally in order to show individual floors it is more accurate and quicker to filter for ALL the other floor levels together and then freeze these level off, as shown
in the tutorial. Is SHOW 00 = ??????01*, *|??????01*,??????02*, *|??????02*,??????03*, *|??????03*,
No xref filters set up ie *| infront of all the non xref filters. [-2]
Ideally the same combined Xref and non-Xref filters should have been used in both model and drawing files. [-1]
Plans of all levels incorrectly shown in a single viewport which cannot be possible if the plans are correctly stacked on top of each other as recommended. [-3]
No variation demonstrated in the level of detail appearing on the sections/different scaled viewports. [-2] 1:100 viewports show 1:50 and 1:10 details
Good non level dependant layering to form the elevations and sections.

-2

BLOCKS

1/10

Blocks attempt +1
Simple blocks correctly set up with elements on LAYER 0 or 1:100 layers, BYBLOCK, BYBLOCK, BYBLOCK, however in complex blocks 1:50 and 1:10 detail
should be ideally BYLAYER,BYLAYER,BYLAYER [-2]

-2

Minimal use of blocks, several other opportunities to create blocks for repeated elements not undertaken. [-1]
No attribute blocks constructed Ideally all attributes should be on different layers to give greater flexibility [-3]

-4

-3

-4

Blocks on plan incorrectly constructed with elements on level dependant layers which restricts the use of these blocks to this single level. Ideally the contents
of these block should be on non-level dependant layers and then inserted on a level dependant layersee escalator blocks.[-1]

-1

No attribute extraction demonstrated. [-4]


No automatic update possible in model file [-1]
No excel *.xls file submitted [-1]
No extraction template file *.dxe file submitted [-1]

-4

CAD DRAUGHTMANSHIP

3/10

Minimal draughting demonstrated projection at 90o has not been modelled as required by the brief dimensions used for section and elevation appear to be
different to those used for the plans[-3]
Single model generally well laid out though section is NOT at 90o as required by the brief.
Co-ordination between plans elevations and sections could be better, with elements on the plans not reflecting accurately their position on other projections[-2]

-3

Section lines on the plan with references in the model would make understanding easier. [-2]
No hyperlinks added to section lines to assist navigation [-1]

-2

SME XREF PUBLICATION

3/10

-2

Plans elevations sections published


Xref files not submitted/used, ideally 4No [-1] no attribute table published
Xref's published but should have used 0,0,0 in the WORLD UCS as the base point [-2]
Xref''s not attached on A000G5 [-1]
All xrefs ideally should have the same insertion/base point 0,0,0 in WORLD UCS and not random points for each xref as is the case here. [-3]

-6

Xrefs attached using saved pathnames not as recommended. [-1] ie D:\Users\Anwar\Desktop\CAD 2A\cad 2a prints\LINKED FILES\First Floor plan.dwg

-1

PRESENTATION

3/10

A1/A3 layout set up.


Viewports accurately scaled though do not show any of the model from the files submitted [-3].

-3

Titleblock and text ideally should be on A010T5 [if otherwise -1]


Titleblock not set up as attributed block [-1]

-1
-1

A3 hardcopy output correctly plotted using a monochrome plot style


Limited variation in pen thicknesses would have improved the A3 hard copy output. [-1]
No plot style *.ctb file submitted [-1]

-2