Heating Controller
476
RVP320
CE1N2476E
27.03.2006
Building Technologies
HVAC Products
Functions
Heating zone control
Weather-dependent flow temperature control through control of the seat or slipper valve
in a heating zone and demand-compensated control of the boiler temperature through
control of the burner
D.h.w. control
Operating modes
Automatic mode
Automatic changeover from normal to reduced temperature, and vice versa,
according to the weekly program, automatic changeover to holiday mode, demand-dependent control of heating system (ECO function)
Setback mode
Continuous heating to the reduced temperature, with ECO function
Comfort mode
Continuous heating to the normal temperature, no ECO function
Standby
.
Optimization functions
Protective functions
Remote control
Commissioning aids
Communication functions
Ordering
When ordering, please give type reference RVP320 and the language code letter (-A, -B
or -C) for the Operating Instructions and the Installation Instructions in the requested
language:
-A for English, French, Italian, German (e.g. RVP320-A for English)
-B for French, Dutch, Spanish (e.g. RVP320-B for French)
-C for Danish, Finnish, Swedish, Greek (e.g. RVP320-C for Danish)
.
.
.
.
.
.
Sensors, room unit, actuators and valves must be ordered as separate items.
Equipment combinations
Suitable sensors and
room units
Suitable actuators
Flow, return and d.h.w. temperature: all sensors with LG-Ni 1000 at 0 C, e.g.:
Strap-on temperature sensor QAD22
Immersion temperature sensors QAE212 and QAP21.3
Room temperature:
Room unit QAW50
Room unit QAW70
Room temperature sensor QAA24
Outside temperature:
Outside sensor QAC22 (Ni sensing element)
Outside sensor QAC32 (NTC sensing element)
2/8
Building Technologies
HVAC Products
CE1N2476E
27.03.2006
Communication
Technical design
Plant types
Picture
2476S01
30
Space heating with mixing
zone, 3-position control or
2-position control acting on
seat or slipper valve.
Precontrol with boiler
LPB
B9
B2
E1
N1
A6 B5
Y1
M1
B1
M2
E2
B7
31
B9
LPB
N1
B2
E1
M1
A6 B5
B1
Y1
M3
B31
M2
B7
A6
B1
B2
B31
B5
B7
B9
E1
E2
K6
K6
2476S02
E2
K6
LPB
M1
M2
M3
N1
Y1
Load (room)
Electric immersion heater / circulating pump
Data bus
Heating circuit pump
Circulating pump
Charging pump
Controller RVP320
Seat or slipper valve
Working principle
The RVP320 offers 2 different plant types that are ready programmed in the controller.
When commissioning the system, the respective plant type must be entered. This activates all functions that are required for the selected plant type. The standard settings
are practice-oriented.
All functions not required for the selected plant type will not be shown and are disabled.
Enduser settings
With weather-dependent control, the flow temperature is controlled in function of the prevailing outside temperature via the heating curve. Its basic setting is made on 2 operating lines. The room temperature can be readjusted with the knob.
In addition, the following can be entered by the enduser:
Room temperature set values for normal heating, reduced heating and frost protection/holidays
D.h.w. temperature setpoint
2 weekly switching programs and one holiday period per year
Operating mode
Time of day and date
Temperature
acquisition
Outside temperature: with Ni or NTC sensor; the RVP320 identifies the type of sensor used. With interlinked controllers, it is also possible to define the source of the
outside temperature
Room temperature: with a room temperature sensor or a room unit or both (averaging)
3/8
Building Technologies
HVAC Products
CE1N2476E
27.03.2006
Space heating
The room temperature is included in the control. It can be acquired with a sensor or
simulated by a room model with an adjustable building time constant. When using a
sensor, the effect on the control can be adjusted.
It is also possible to limit the maximum room temperature.
The heating is switched on and off depending on demand (ECO function). It is switched off when the amount of heat stored by the building mass is sufficient to maintain the required room temperature. In that case, the controller takes into account the
development of the room temperature and the building's heat storage capacity. It is
possible to set 2 heating limits, one for normal heating and one for reduced heating.
The control is optimized. Switching on, heating up and shutting down are controlled
such that, during occupancy times, the required room temperature is always maintained.
At the end of each occupancy period, the heating will be shut down (circulating
pump) until the room temperature set value for the non-occupancy time is reached
(quick setback, can be disabled). During heating up, the room temperature set value
can be boosted (boost heating). It is possible to set maximum limits for the heating
up time and for early shutdown.
Control
Heating zone control
The heating zone control operates as weather-dependent flow temperature control with
3-position or 2-position control. The flow temperature is controlled via the regulating
unit (seat or slipper valve).
Minimum and maximum limitation of the flow temperature as well as maximum limitation of the rate of set value rise are adjust.
Boiler control
Minimum limitation of
return temperature
Minimum limitation of the return temperature helps prevent flue gas condensation.
Locking functions
On the software side, all settings can be locked to prevent unauthorized readjustments.
Time switch
The RVP320 has 2 independent weekly time switches whose assignment can be
selected. Each weekly time switch affords 3 daily on periods, which may differ from
one weekday to the other.
For entering a holiday period, the RVP320 is equipped with a yearly time switch
featuring automatic summer- / wintertime changeover.
D.h.w. heating
4/8
Building Technologies
HVAC Products
CE1N2476E
27.03.2006
Remote control
Communication
Communication with other devices is effected via the data bus and allows:
Signaling of heat demand to the heat generator
Exchange of locking and enforced signals
Exchange of measured values such as outside temperature and return temperature
as well as clock signals
Communication with other devices
Reception of heat demand from the SYNERGYR OZW30 central unit (from software
version 3.0)
Exchange of error messages
Error messages
Other functions
Mechanical design
The RVP320 is comprised of controller insert, which accommodates the electronics, the
power section, the output relays and on the front all operating elements, and the
base, which carries the connection terminals. The operating elements are located behind a cover.
The operating instructions can be inserted in the cover.
The controller insert is secured to the base with 2 screws.
The RVP320 can be fitted in 3 different ways:
Wall mounting (on a wall, in the control panel, etc.)
Rail mounting (on a standard DIN mounting rail)
Flush panel mounting (control panel door, etc.)
Analog operating
elements
5/8
Building Technologies
HVAC Products
CE1N2476E
27.03.2006
Digital operating
elements
The entry or readjustment of all setting parameters, activation of optional functions and
reading of actual values and statuses is made according to the operating line principle.
An operating line with an associated number is assigned to each parameter, each actual value and each function that can be selected.
One pair of buttons is used to select an operating line and one pair to readjust the display.
1
2476Z01
8
BUS
9
10
3
4
Landis & Staefa
RVP320
5
6
1
2
3
11
Operating mode buttons
(selected button is lit)
Service plug
Buttons for operating the display:
Prog = selection of operating line
+ = readjustment of displayed value
Operating instructions
5
6
7
8
9
10
11
Notes
Engineering
The wires of the measuring circuits carry extra low voltage, those to the actuator and
the pump carry AC 24230 V.
The local electrical regulations must be complied with.
Sensor cables should not be run parallel to mains carrying cables for loads such as
actuator, pump, burner, etc.
Commissioning
Technical data
General data
Standards
AC 230 V +10/15 %
50 Hz
9 VA
25+65 C
050 C
7
12 h min.
0,84 kg
EN 60730-1
EN 60730-2-9
IP40 to EN 60529
II to EN 60730
89/336/EWG
73/23/EWG
6/8
Building Technologies
HVAC Products
CE1N2476E
27.03.2006
EMC directive
Electromagnetic immunity
Electromagnetic emissions
EN 50082-2
EN 50081-1
Output relays
Rated voltage
Rated current
Contact current at AC 2490 V
Contact current at AC 90250 V
Rated current of ignition transformer
Switch-on current of ignition transformer
Max. switch-on current (fuse)
AC 230 V
2 (2) A
0,12 A, cos >0,6
0,022 A, cos >0,6
1 A max. (30 s max.)
10 A max. (10 ms max.)
10 A max.
20 m
80 m
120 m
25 m
50 m
Connection diagrams
B2
LPB
2476A01
D1 D2
B9
B2
B31
B7
B5 M
N1
F7
F1/F2
Q1
Q3
Y1
Y2
Q2
K6
1
F1
F2
1.
M1
M3
Y1
M2
2.
A6
B1
B2
B31
B5
B7
B9
E1
F1
F2
LPB
M1
M2
M3
N1
S1
Y1
1
)
N1
2476A02
AC 230 V
7/8
Building Technologies
HVAC Products
CE1N2476E
27.03.2006
Dimensions
19
max. 3
96
93
12
144
106,8
138
+1
0
92 +10
4,5
60,4
14
56
112
2474M01
15
26 26 26 26
Dimensions in mm
8/8
Building Technologies
HVAC Products
CE1N2476E
27.03.2006