Journal of Chromatography A
journal homepage: www.elsevier.com/locate/chroma
Life Sciences Division, Korea Institute of Science & Technology, 39-1 Hawolkok-dong, Seoul 136-791, South Korea
Department of Chemistry, Yonsei University, Seoul 120-749, South Korea
c
Forensic Science Division, Supreme Prosecutors Ofce, Seoul 137-730, South Korea
b
a r t i c l e
i n f o
Article history:
Received 5 March 2008
Received in revised form 16 July 2008
Accepted 17 July 2008
Available online 5 August 2008
Keywords:
Cannabinoids
-Cyclodextrin
Solid-phase extraction
Inclusion complex
GCMS
a b s t r a c t
A comprehensive solid-phase extraction (SPE) technique based on the formation of an inclusion complex
between -cyclodextrin (CD) and cannabinoids including 9 -tetrahydrocannabinol (THC), 11-hydroxy9 -tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-9 -tetrahydrocannabinol (THC-COOH)
was developed in gas chromatographicmass spectrometric (GCMS) analysis. A CD/epichlorohydrin
copolymer was prepared and then hardened in aqueous solution with 0.3 M CaCl2 to yield a stable particulate copolymer, which was used as a novel SPE sorbent. An internal standard THC-COOH-d9 was added to
urine samples containing 3 cannabinoids and then puried with the hardened CD polymer. The cannabinoids were extracted from the hardened CD using tetrahydrofuran. Resulting extracts were evaporated
and derivatized with MSTFA/NH4 I/dithioerythritol (500:4:2, v/w/w) and analyzed by GCMS in selectedion monitoring (SIM) mode. Overall recoveries ranged from 85% to 102%, with a detection limit of 0.2 g L1
for the three cannabinoids tested. The precision (% CV) and accuracy (% bias) of the assay were 1.25.1%
and 93111% in 0.250 g L1 calibration range, respectively (r2 > 0.9997). Twenty actual samples positive by uorescence polarization immunoassay were also quantitatively analyzed. The devised technique
based on the calcium-hardened CD sorption of cannabinoids and subsequent GCSIM/MS resulted in
better selectivity and extraction efciency than is possible using the conventional hydrophobicity-based
SPE methods.
2008 Elsevier B.V. All rights reserved.
1. Introduction
THC (9 -tetrahydrocannabinol) is one of the most widely
used drugs of abuse. It occurs naturally in the marijuana plant
Canabis sativa and it is rapidly metabolized to 11-hydroxy9 -tetrahydrocannabinol (11-OH-THC) and 11-nor-9-carboxy-9 tetrahydrocannabinol (THC-COOH) in liver and other tissues (Fig. 1)
[15]. Cannabinoids accumulate in body fat due to their lipophilic
characters, and are slowly excreted from the body. In addition, urinary THC-COOH is an indicator of THC, and can be detected in
infrequent users for a few days and in frequent users for weeks
or even months after administration [6,7].
Analysis of cannabinoids in biological samples, such as urine,
plasma, hair, and oral uid, is commonly performed using GCMS
Corresponding author. Tel.: +82 2 958 5081; fax: +82 2 958 5059.
E-mail address: mh choi@kist.re.kr (M.H. Choi).
0021-9673/$ see front matter 2008 Elsevier B.V. All rights reserved.
doi:10.1016/j.chroma.2008.07.083
88
Fig. 1. Major metabolic pathways of 9 -tetrahydrocannabinol and the internal standard used.
presents a hydrophilic surface that conceals a hydrophobic interior. These hydrophobic regions are responsible for its absorbing
hydrophobic guest molecules to form inclusion complexes [1618].
Although cyclodextrin SPE has been shown to effectively binding
steroids [1921], its practical applications center on the isolation of hydrophobic species usually in combination with liquid
chromatography (LC) or capillary electrophoresis (CE) [2225].
Moreover, although CD-based soft gels, like SPE sorbents, bind
steroids effectively, their practical applications are limited because
of their gel-like characteristics, i.e., their intrinsic swelling in aqueous solutions [16,26].
The inclusion-complex-based SPE with CD was successfully
applied with urinary steroids [27] and it could be expanded to
include other steroidal compounds and possibly other biological
compounds as universal extraction sorbents. Due to the structural similarities of cannabinoids and steroids, inclusion complexes
of cannabinoids in CD have been administered sublingually to
improve bioavailability [2831]. To investigate the binding afnity
of CD polymer as an alternative SPE sorbent for urinary cannabinoid analysis, the present study was designed and tested with the
calcium-hardened CD polymer. However, no study has been conducted on the use of these complexes for urinary cannabinoids
analysis. Here, we describe a method for the quantitative analysis
of THC, 11-OH-THC, and THC-COOH in human urine using calciumhardened CD polymer.
2. Materials and methods
2.1. Chemicals
THC, 11-OH-THC, THC-COOH and THC-COOH-d9 (internal standard, IS) were obtained from Cerilliant (Round Rock, TX; Fig. 1).
N-Methyl-N-triuorotrimethylsilyl acetamide (MSTFA), ammonium iodide (NH4 I), and dithioerythritol (DTE) were purchased
from Sigma (St. Louis, MO). -Cyclodextrin (CD) and epichlorohydrin were obtained from SigmaAldrich (St. Louis, MO). A 50%
glycerol solution of -glucuronidase from E coli (140 U mL1 ) was
purchased from Roche (Mannheim, Germany). All organic solvents
used were of analytical or HPLC grade and were purchased from
Burdick & Jackson (Muskegan, MI).
Stock solutions of cannabinoid reference standards were prepared at 10 mg L1 in methanol, and working solutions were made
89
Fig. 2. Detection windows for the analysis of cannabinoids as trimethylsilyl derivatives obtained from (A) a urinary blank and (B) a spiked urine sample at urinary concentration
of 2 g L1 . Ions were selected at m/z 386 (THC) and 371 (THC-OH and THC-COOH) for quantication. Three characteristic ions of each cannabinoid were monitored.
(2 L) was injected in split mode (10:1) at 280 C, using the following GC conditions: initial oven temperature 200 C ramped to
240 C at 8 C min1 , and then to 310 C at 10 C min1 and held for
5 min. Helium was used as carrier gas at a column head pressure
of 173 kPa (column ow: 0.8 C min1 at an oven temperature of
200 C).
90
Table 1
Intra- and inter-day validation results of the overall method
Intra-day (n = 3)
1
Concentration (g L
THC
r2 = 0.9999
11-OH-THC
r2 = 0.9997
THC-COOH
r2 = 0.9999
Inter-day (n = 4)
1
Mean SD (g L
CV (%)
Accuracy (%)
Mean SD (g L1 )
CV (%)
Accuracy (%)
1
5
20
0.93 0.01
4.90 0.25
20.33 0.27
1.2
5.1
1.3
93.1
98.0
101.7
1.04 0.02
4.85 0.20
19.65 0.49
2.3
4.1
2.5
103.7
97.0
98.3
1
5
20
1.02 0.01
4.76 0.24
20.01 0.35
1.3
4.9
1.8
102.1
95.2
100.1
1.11 0.02
4.93 0.21
19.71 0.60
2.0
4.2
3.0
111.3
98.5
98.6
1
5
20
1.06 0.04
4.71 0.21
20.43 0.61
3.5
4.5
3.0
105.8
94.2
102.1
1.11 0.06
4.91 0.25
20.19 0.64
4.8
5.0
3.0
111.1
98.3
101.0
A routine procedure based on the use of Oasis HLBTM SPE cartridges (60 mg, 3 mL; Waters), preconditioned with methanol and
water (1 mL each), was used for control purposes. Briey, urine
samples (2 mL) were spiked with 20 L of IS (1 mg L1 ) in 1 mL of
phosphate buffer (0.2 M, pH 7.2), and then incubated with 50 L
of -glucuronidase for 1 h at 55 C. SPE cartridges were placed
in a device tted with a small peristaltic pump and each was
washed with 2 mL water and eluted twice with 1.5 mL of methanol.
Combined methanol eluates were evaporated under a stream of
nitrogen, and residues were further dried in a vacuum desiccator over P2 O5 KOH for 30 min. Dried extracts were derivatized as
described for isolated cannabinoids above.
2.5. Method validation
The QC samples containing all three analytes at different concentrations (1, 5 and 20 g L1 ) were used over a period of 3 months.
Quantication was performed using peak height ratios relative to
that of the IS and calibration samples were made up at eight different concentrations (0.2, 0.5, 1, 2, 5, 10, 20, and 50 g L1 ) and each
sample treated with CD powder followed by trimethylsilylation.
Response linearity was measured in triplicate for the eight-point
calibrations. Limits of detection (LOD) and of quantication (LOQ)
were dened as lowest concentrations with a signal-to-noise (S/N)
ratio of higher than 3 and 10, respectively.
Precision is expressed as coefcient of variation (% CV) and accuracy as percent relative error (% bias), and were determined from QC
samples at 1, 5, and 20 g L1 . In terms of within-day repeatability,
triplicates were analyzed, whereas reproducibility was measured
from results obtained on four different days. Extraction recovery
91
Table 2
Extraction recoveries for 5-times-recycled -cyclodextrin powder
Concentration (g L1 )
Extraction recovery, % (n = 3)
New polymerized CD powder
THC
1
5
20
99.3
89.3
86.6
89.0 (7.3)
84.4 (3.4)
84.8 (1.2)
11-OH-THC
1
5
20
99.4
87.1
85.7
97.9 (1.1)
82.2 (3.4)
84.7 (0.7)
THC-COOH
1
5
20
102.1
90.8
88.5
102.9 (0.5)
90.2 (0.4)
80.9 (1.7)
Table 3
Analysis of cannabinoids in urine samples from marijuana abusers
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
THC (g L1 )
11-OH-THC (g L1 )
THC-COOH (g L1 )
ND
ND
ND
ND
ND
ND
1.73
ND
ND
ND
ND
ND
ND
ND
ND
0.36
ND
ND
ND
ND
2.52
ND
ND
ND
ND
ND
ND
ND
ND
ND
1.09
ND
ND
ND
ND
2.34
ND
ND
ND
ND
32.56
33.19
4.91
28.93
4.76
1.54
15.28
0.95
1.97
3.52
20.28
5.31
5.67
5.43
12.10
45.25
7.98
8.21
39.55
3.95
92