Anda di halaman 1dari 105

WCDMA Handover Principle

and Relevant Parameters

Page1

Foreword
Why mobile systems need handover?
It is decided by the characters of mobile system:
The mobility of UE
The mobile system is composed by cells which the coverage ability is

limited.
Providing the continuous service in mobile system is the basic element
in QoS.

Page2

Objectives
Upon completion of this course, you will be able to:
Know the basic definitions of Handover
The algorithms of handover decision
The handover flow
The parameters of handover

Page3

Contents
1. Introduction of Handover
2. Measurement of Handover
3. The Basic Handovers

Page4

Contents
1. Introduction of Handover
2. Measurement of Handover
3. The Basic Handovers

Page5

The Purpose of Handover


Providing the continuous service in mobile system is the

basic element in QoS


The load balance: sharing the resource
The hierarchy divided by speed and service: high
efficiency of using resource

Page6

The Basic Concepts of Handover


Active Set
Monitored Set
Detected set
Radio Link (RL)
Radio Link Set

(RLS)

maximum ratio combination


selection combination
The soft handover gain
CPICH

Page7

The Categories of Handover


According to the signaling characters
Soft handover (softer handover)
Hard handover

According to the properties of source cell and target cell:


Intra-frequency handover
Inter-frequency handover
Inter-RAT handover (UMTS

GSM/GPRS)

According to the purpose of handover:


Based on Coverage
Based on Noncoverage

The Characters of Different Handover

Comparison between soft handover and hard handover:

Item
The number of RLs in

Soft Handover

Hard Handover

Several

One

No

Yes

Only happened

Can be happened in Intra-

between Intra-

frequency cells or Inter-frequency

frequency cells

cells

active set after handover


Interruption during
handover
The frequencies of cells

Page8

The Characters of Different Handover


Comparison between soft handover and softer handover :

Item
UL combination

Soft Handover

Softer Handover

Signal combined in

Signal combined in NodeB by

RNC by selective

maximum ratio combination

combination
DL combination

Signal combined in

Signal combined in UE by

UE by maximum ratio

maximum ratio combination

combination

Page9

Soft Handover
RNC

NodeB 1

NodeB 2

Cell A

Cell B

Page10

Softer Handover
RNC

NodeB

Cell A
Cell B

Page11

Hard Handover
RNC

NodeB 1

NodeB 2

Cell A

Cell B

Page12

Three Steps of Handover


The following figure shows handover
procedure (measurement quality set to
PCPICH Ec/No)
Measure the CPICH Ec/N0 of the serving cell and
its neighboring cells as well as the relative time
difference between the cells

Measurement

Measurement phase

Decision

No

Execution

Are handover criteria satisfied?

Decision phase

Yes

Perform a handover and update relative parameters

Page13

Execution phase

Page14

Contents
1. Introduction of Handover
2. Measurement of Handover
3. The Basic Handovers

Page15

Contents
2. Measurement of Handover
2.1 Measurement Control and Measurement Report
2.2 Measurement Phase

Page16

Measurement Control

UE

UTRAN

MEASUREMENT CONTROL

Measurement Control, normal case

Page17

Measurement Report

UE

UTRAN

MEASUREMENT REPORT

Measurement Control, normal case

Page18

Contents
2. Measurement of Handover
2.1 Measurement Control and Measurement Report
2.2 Measurement Phase

Page19

Measurement Model
parameters

parameters

Layer 1
filtering

Layer 3
filtering

C
C'

Evaluation
of reporting
criteria

A is measurement value at the physical layer


B is the measurement value after layer 1 filtering at physical layer. The

value goes from the physical layer to high layer


C is measurement after processing in the layer3 filter
C is another measurement value
D is measurement report information sent on the radio interface or Iub

interface

Page20

Measurement Quantity

Ec/No
CPICH signal quality

RSCP
CPICH signal level

RSSI
GSM cell signal level

Page21

Measurement Quantity Configuration


IntraFreqMeasQuantity
Parameter name: Intra-frequency measure quantity
The default value of this parameter is Ec/No

InterFreqMeasQuantity
Parameter name: Inter-frequency measure quantity
The default value of this parameter is Both

MeasQuantityOf3A
Parameter name: 3A Measure Quantity
The default value of this parameter is RSCP

Page22

Layer 3 filtering
Fn = (1 a ) Fn 1 + a M n
Where:
Fn is the new measurement value after filtering.
Fn-1 is the last measurement value after filtering.
Mn is the latest measurement value from the physical layer.
a = 1/2(k/2)

(k is set to Intra-freq meas L3 filter coeff)

Page23

Layer 3 filtering coefficient


FilterCoef
Parameter name: Intra-frequency measurement filter coefficient
The default value of this parameter is D3

InterFreqFilterCoef
Parameter name: Inter-frequency measure filter coefficient
The default value of this parameter is D3

InterRATFilterCoef
Parameter name: Inter-RAT filter coefficient
The default value of this parameter is D3

Page24

Measurement Report Mode


Periodic Report
Event Trigger Report
Event to Periodic Report

Page25

Contents
1. Introduction of Handover
2. Measurement of Handover
3. The Basic Handovers

Page26

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Page27

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Page28

Brief Introduction of Soft Handover


Characters of Soft Handover
During handover, UE has several RLs with different cells
The handover among different cells which are in same RLS can be

softer handover
Signals from each RL will be combined in UL and DL.

Page29

Brief Introduction of Soft Handover


Advantages
Soft handover gain
Decrease the possibility of call drop

Disadvantages
More resource needed in downlink
it way cause side-effect

Page30

Measurement of Soft Handover


Measurement quantity
CPICH RSCP
CPICH Ec/No

Reporting mode
Periodic reporting
Event trigger reporting
Event trigger reporting to Periodic reporting

Event type
1A,1B,1C,1D,1F

Soft Handover Measurement Events


Event

Description

1A

The PCPICH quality of the cells in the monitored set enters the reporting range .
This indicates that the quality of a cell is close to the quality of the best cell . A
relative high combined gain can be achieved when the cell is added to the active
set

1B

The PCPICH quality of the cells in the active set leaves the reporting range. This
indicates that quality of a cell is much worse than the quality of the best cell. The
cell should not stay in the active set

1C

A non-active PCPICH becomes better than an active PCPICH. This indicates that
the quality of a cell is close to the quality of the best cell. In addition ,the number of
cells in the active set has reached the maximum value. The cell replaces the worst
cell in the active set ; thus achieving a higher combined gain

1D

Event of the change of the best cell

Page31

The Trigger Algorithm of 1A Event


Event 1A is triggered on the basis of the following formula

NA

10 LogM New + CIONew W 10 Log

M i + (1 W ) 10 LogM Best ( R1a H1a / 2),


i =1

Page32

Page33

Example of 1A Event

A: signal curve of the best cell in the active set


B: signal curve of a cell in the monitoring set
C: The 1A curve

Page34

Key parameters of 1A Event


INTRARELTHDFOR1ACS
Parameter name: CS service 1A event relative threshold
The default value of this parameter is 6 ( 3dB )
INTRARELTHDFOR1APS
Parameter name: PS service 1A event relative threshold
The default value of this parameter is 6 ( 3dB )

Page35

Key parameters of 1A Event


HYSTFOR1A
Parameter name: 1A event hysteresis
The default value of this parameter is 0( 0dB )
TRIGTIME1A
Parameter name: 1A event trigger delay time
The default value of this parameter is D320 ( 320ms )

The Trigger Algorithm of 1B Event


Event 1B is triggered on the basis of the following formula

NA

10 LogM Old + CIOOld W 10 Log

M i + (1 W ) 10 LogM Best ( R1b + H 1b / 2),


i =1

Page36

Page37

Example of 1B Event

A: signal curve of the best cell in the active set


B: signal curve of a cell in the monitoring set
C: The 1B curve

Page38

Key parameters of 1B Event


INTRARELTHDFOR1BCS
Parameter name: CS service 1B event relative threshold
The default value of this parameter is 12 ( 6dB )
INTRARELTHDFOR1BPS
Parameter name: PS service 1B event relative threshold
The default value of this parameter is 12 ( 6dB )

Page39

Key parameters of 1B Event


HYSTFOR1B
Parameter name: 1B event hysteresis
The default value of this parameter is 0( 0dB )
TRIGTIME1B
Parameter name: 1B event trigger delay time
The default value of this parameter is D640 ( 640ms )

Page40

The Trigger Algorithm of 1C Event


Event 1C is triggered on the basis of the following formula

10 LogM New + CIONew 10 LogM InAS + CIOInAS + H1c / 2,

Page41

Example of 1C Event

A: signal curve of the best cell in the active set


B: signal curve of a cell in the active set
C: signal curve of the worst cell in the active set
D: signal curve of a cell in the monitoring set
E: The 1C curve

Page42

Key parameters of 1C Event


HYSTFOR1C
Parameter name: 1C event hysteresis
The default value of this parameter is 8( 4dB )
TRIGTIME1C
Parameter name: 1C event trigger delay time
The default value of this parameter is D640 ( 640ms )

Page43

The Trigger Algorithm of 1D Event


Event 1D is triggered on the basis of the following formula

10 LogM New 10 LogM InAS + H1c / 2,

Page44

Example of 1D Event

A: signal curve of the best cell in the active set


B: signal curve of a cell in the active set or monitoring set
C: Th1D curve

Page45

Key parameters of 1D Event


HYSTFOR1D
Parameter name: 1D event hysteresis
The default value of this parameter is 8( 4dB )
TRIGTIME1D
Parameter name: 1D event trigger delay time
The default value of this parameter is D640 ( 640ms )

Page46

Other key parameters for SHO


Weight
Parameter name: Weighted factor
The default value of this parameter is 0

SHOQualmin
Parameter name: Min quality THD for SHO
The default value of this parameter is -24(-24 dB)

CELLINDIVIDALOFFSET
Parameter name: Cell offset
The default value of this parameter is 0 ( 0dB )

Page47

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Page48

Brief Introduction of Intra-Frequency Handover


Characters of Intra-Frequency Handover
During handover, UE has only one RL with one cell
Switch off the RL with the original cell, then setup the RL with target

cell
The frequency of source cell and target cell are same

Page49

Brief Introduction of Intra-Frequency Handover


Advantages
Enhance the usage efficiency of the OVSF code and hardware

Disadvantages
High call drop possibility because of the intra-frequency interference

Page50

Key parameters of Intra-frequency Hard handover


BEBITRATETHD
Parameter name: BE service handover rate threshold
The default value of this parameter is 384k
The Parameters about 1D Event
Time to trigger
Hysteresis

Page51

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Page52

Brief Introduction of Inter-Frequency Handover


Characters of Soft Handover
The frequency of original cell and source cell are different
There is only one RL for the UE
The compressed mode is needed

Page53

Compressed Mode
Purpose
Measure the inter-frequency cell or Inter-RAT cell under FDD mode

Categories
Downlink compressed mode
Uplink compressed mode

Realization Methods
SF/2
Higher layer scheduling

Page54

Measurement of Inter-frequency Handover


Measurement quantity
CPICH RSCP
CPICH Ec/No

Reporting mode
Periodic reporting
Event trigger reporting
Event trigger reporting to Periodic reporting

Event type
2B,2C,2D,2F

Inter-frequency Handover Measurement Events


Event
2D

Description
When the current signal quality is lower than the preset threshold , the
UTRAN enables the compressed mode and starts inter-frequency
measurement

2F

When the current signal quality is higher than the preset threshold, the
UTRAN disables the compressed mode and stops inter-frequency
measurement

2B

When the current signal frequency is lower than the preset threshold and
the signal quality of an inter-frequency neighbouring cell is higher than
the preset threshold , the UTRAN trigger an inter-frequency handover
based on coverage

2C

The estimated quality of a inter-frequency neighbor cell is higher than the


preset threshold

Page55

The Trigger Algorithm of 2D Event


Event 2D is triggered on the basis of the following formula

QUsed TUsed 2d H2d / 2

Page56

Page57

Key parameters of of 2D Event


InterFreqCSThd2DEcN0
Parameter name: Inter-freq CS measure start Ec/No THD
The default value of this parameter is -14 dB
InterFreqPSThd2DEcN0
Parameter name: Inter-freq PS measure start Ec/No THD
The default value of this parameter is -14 dB

Page58

Key parameters of of 2D Event


InterFreqCSThd2DRSCP
Parameter name: Inter-freq CS measure start RSCP THD
The default value of this parameter is -95 dBm
InterFreqPSThd2DRSCP
Parameter name: Inter-freq PS measure start RSCP THD
The default value of this parameter is -95 dBm

Page59

Key parameters of 2D Event


HYSTFOR2D
Parameter name: 2D event hysteresis
The default value of this parameter is 4( 2dB )
TRIGTIME2D
Parameter name: 2D event trigger delay time
The default value of this parameter is D320 ( 320ms )

The Trigger Algorithm of 2F Event


Event 2F is triggered on the basis of the following formula

QUsed TUsed 2 f + H 2 f / 2

Page60

Page61

Key parameters of 2F Event


InterFreqCSThd2FEcN0
Parameter name: Inter-freq CS measure stop Ec/No THD
The default value of this parameter is -12 dB
InterFreqPSThd2FEcN0
Parameter name: Inter-freq PS measure stop Ec/No THD
The default value of this parameter is -12 dB

Page62

Key parameters of 2F Event


InterFreqCSThd2FRSCP
Parameter name: Inter-freq CS measure stop RSCP THD
The default value of this parameter is -92 dBm
InterFreqPSThd2FRSCP
Parameter name: Inter-freq PS measure stop RSCP THD
The default value of this parameter is -92 dBm

Page63

Key parameters of 2F Event


HYSTFOR2F
Parameter name: 2F event hysteresis
The default value of this parameter is 4( 2dB )
TRIGTIME2F
Parameter name: 2F event trigger delay time
The default value of this parameter is D1280 ( 1280ms )

The Trigger Algorithm of 2B Event


Event 2B is triggered on the basis of the following formula

QNonused TNonused 2b + H2b / 2

, and

QUsed TUsed 2b H2b / 2

Page64

Page65

Key parameters of 2B Event


InterFreqCovHOCSThdEcN0
Parameter name: Inter-freq CS target frequency trigger Ec/No THD
The default value of this parameter is -12 dB
InterFreqCovHOPSThdEcN0
Parameter name: Inter-freq PS target frequency trigger Ec/No THD
The default value of this parameter is -12 dB

Page66

Key parameters of 2B Event


InterFreqCovHOCSThdRSCP
Parameter name: Inter-freq CS target frequency trigger RSCP THD
The default value of this parameter is -92 dBm
InterFreqCovHOPSThdRSCP
Parameter name: Inter-freq PS target frequency trigger RSCP THD
The default value of this parameter is -92 dBm

Page67

Key parameters of 2B Event


IFHOUsedFreqCSThdEcN0
Parameter name: Inter-freq CS Used frequency trigger Ec/No THD
The default value of this parameter is -12dB
IFHOUsedFreqPSThdEcN0
Parameter name: Inter-freq PS Used frequency trigger Ec/No THD
The default value of this parameter is -12 dB

Page68

Key parameters of 2B Event


IFHOUsedFreqCSThdRSCP
Parameter name: Inter-freq CS Used frequency trigger RSCP THD
The default value of this parameter is -92dBm
IFHOUsedFreqPSThdRSCP
Parameter name: Inter-freq PS Used frequency trigger RSCP THD
The default value of this parameter is -92 dBm

Page69

Key parameters of 2B Event


HYSTFOR2B
Parameter name: 2B event hysteresis
The default value of this parameter is 4( 2dB )
TRIGTIME2B
Parameter name: 2B event trigger delay time
The default value of this parameter is D0 ( 0ms )

The Trigger Algorithm of 2C Event


Event 2C is triggered on the basis of the following formula

QNon used TNon used 2c + H 2c / 2

Page70

Page71

Key parameters of 2C Event


InterFreqNCovHOThdEcN0
Parameter name: Inter-freq CS target frequency trigger Ec/No THD
The default value of this parameter is -16 dB

Hystfor2C
Parameter name: 2C hysteresis
The default value of this parameter is 6 (3dB)

TrigTime2C
Parameter name: 2C event trigger delay time
The default value of this parameter is D640 (640ms)

Page72

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Page73

Brief Introduction of Inter-RAT Handover


Characters of Inter-RAT Handover
Based on handover directions, inter-RAT handover is of two
types:
UMTS->GSM handover
UMTS->GSM coverage-based handover
UMTS->GSM load-based handover
UMTS->GSM service-based handover
GSM->UMTS handover

Page74

Brief Introduction of Inter-RAT Handover


Advantages
For coverage, it can solve the problems from one system to

another system
For capacity, it can enhance the utilizing efficiency of old

equipments(2G->3G)

Disadvantages
The flow is complicated, and it demands higher compatibility for

equipments
Demands more complicated UE

Page75

Measurement of Inter-RAT Handover


Measurement quantity
CPICH_Ec/N0
CPICH_RSCP
BOTH

Reporting mode
PERIODICAL_REPORTING
EVENT_TRIGGER

Event type
2D, 2F
3A, 3C

Inter-RAT Handover Measurement Events


Event
2D

Description
When the signal quality of the currently used frequency is lower than the preset
threshold, the RNC enables the compressed mode and starts inter-RAT
measurement.

2F

When the signal quality of the currently used frequency is higher than the preset
threshold, the RNC disables the compressed mode and stops inter-RAT
measurement.

3A

When the signal quality of the currently used UMTS frequency is lower than the
preset threshold while the signal quality of any other system is higher than the
preset threshold, the RNC triggers UMTS->GSM handover based on coverage.

3C

When the signal quality of any other system is higher than the preset threshold,
the RNC triggers UMTS->GSM handover based on load or service.

Page76

The Trigger Algorithm of 2D Event


Event 2D is triggered on the basis of the following formula:

Q Used TUsed2d - H 2d / 2

Page77

Page78

Key Parameters of 2D Event


INTERRATCSTHD2DECNO
Parameter name: Inter-RAT CS measure start Ec/No THD
The default value of this parameter is -14 ( -14 dB )
INTERRATPSTHD2DECNO
Parameter name: Inter-RAT PS measure start Ec/No THD
The default value of this parameter is -15 ( -15 dB )

Page79

Key Parameters of 2D Event


INTERRATCSTHD2DRSCP
Parameter name: Inter-RAT CS measure start RSCP THD
The default value of this parameter is -100 ( -100 dBm )
INTERRATPSTHD2DRSCP
Parameter name: Inter-RAT PS measure start RSCP THD
The default value of this parameter is -110 (-110 dBm )

Page80

Key Parameters of 2D Event


HYSTFOR2D
Parameter name: 2D hysteresis
The default value of this parameter is 4 ( 2 dB )
TRIGTIME2D
Parameter name: 2D event trigger delay time
The default value of this parameter is D320 (320 ms )

The Trigger Algorithm of 2F Event


Event 2F is triggered on the basis of the following formula:

Q Used TUsed2f + H 2f / 2

Page81

Page82

Key Parameters of 2F Event


INTERRATCSTHD2FECNO
Parameter name: Inter-RAT CS measure stop Ec/No THD
The default value of this parameter is -12 ( -12 dB )
INTERRATPSTHD2FECNO
Parameter name: Inter-RAT PS measure stop Ec/No THD
The default value of this parameter is -13 ( -13 dB )

Page83

Key Parameters of 2F Event


INTERRATCSTHD2FRSCP
Parameter name: Inter-RAT CS measure stop RSCP THD
The default value of this parameter is -97 ( -97 dBm )
INTERRATPSTHD2FRSCP
Parameter name: Inter-RAT PS measure stop RSCP THD
The default value of this parameter is -107 (-107 dBm )

Page84

Key Parameters of 2F Event


HYSTFOR2F
Parameter name: 2F hysteresis
The default value of this parameter is 4 ( 2 dB )
TRIGTIME2F
Parameter name: 2F event trigger delay time
The default value of this parameter is D1280 (1280 ms )

The Trigger Algorithm of 3A Event


Event 3A is triggered on the basis of the following formula:

Q Used TUsed3a + H 3a / 2
M OtherRat + CIOOtherRat TOtherRat + H 3a / 2

Page85

Page86

Key Parameters of 3A Event


IRHOUSEDFREQCSTHDECNO
Parameter name: Inter-RAT CS Used frequency trigger Ec/No THD
The default value of this parameter is -12 ( -12 dB )
IRHOUSEDFREQPSTHDECNO
Parameter name: Inter-RAT PS Used frequency trigger Ec/No THD
The default value of this parameter is -13 ( -13 dB )

Page87

Key Parameters of 3A Event


IRHOUSEDFREQCSTHDRSCP
Parameter name: Inter-RAT CS Used frequency trigger RSCP THD
The default value of this parameter is -97 ( -97 dBm )
IRHOUSEDFREQCSTHDRSCP
Parameter name: Inter-RAT PS Used frequency trigger RSCP THD
The default value of this parameter is -107 (-107 dBm )

Page88

Key Parameters of 3A Event


INTERRATCOVHOCSTHD
Parameter name: Inter-RAT CS handover decision THD
The default value of this parameter is 16 ( -95 dBm )
INTERRATCOVHOPSTHD
Parameter name: Inter-RAT PS handover decision THD
The default value of this parameter is 16 ( -95 dBm )

Page89

Key Parameters of 3A Event


HYSTFOR3A
Parameter name: 3A hysteresis
The default value of this parameter is 4 ( 2 dB )
TRIGTIME3A
Parameter name: 3A event trigger delay time
The default value of this parameter is D0 ( 0 ms )

Page90

Key Parameters of 3A Event


CELLINDIVIDALOFFSET
Parameter name: Cell individual offset
The default value of this parameter is 0 ( 0 dB )

The Trigger Algorithm of 3C Event


Event 3C is triggered on the basis of the following formula:

M OtherRat + CIOOtherRat TOtherRat + H 3c / 2

Page91

Page92

Key Parameters of 3C Event


INTERRATNCOVHOCSTHD
Parameter name: Inter-RAT CS handover decision THD
The default value of this parameter is 21 ( -90 dBm )
INTERRATNCOVHOPSTHD
Parameter name: Inter-RAT PS handover decision THD
The default value of this parameter is 21 (-90 dBm )

Page93

Key Parameters of 3C Event


HYSTFOR3C
Parameter name: 3C hysteresis
The default value of this parameter is 0 ( 0 dB )
TRIGTIME3C
Parameter name: 3C event trigger delay time
The default value of this parameter is D640 ( 650 ms )

Page94

Key Parameters of 3C Event


PENALTYTIMEFORINTERRATHO
Parameter name: Inter-RAT handover failure penalty timer length
The default value of this parameter is 30 ( 30 s )
INTERRATHOATTEMPTS
Parameter name: Inter-RAT handover max attempt times
The default value of this parameter is 16

Page95

Key Parameters of 3C Event


INTERRATMEASTIME
Parameter name: Inter-RAT measure timer length [s]
The default value of this parameter is 60 ( 60 s )

Page96

Contents
3. The Basic Handovers
3.1 Soft Handover
3.2 Intra-frequency Hard Handover
3.3 Inter-frequency Hard Handover
3.4 Inter-RAT Hard Handover
3.5 Blind Handover

Page97

Blind Handover Measurement


Blind handover means UE can directly handover to the

neighboring cell without measuring it.

Page98

The Trigger Algorithm of 1F Event

10 LogM

T H

/2

Old
1f
1f
Where:
MOld is the measurement value of the cell signal that becomes
worse
T1f is the absolute threshold of event 1F.
H1f is the hysteresis value of event 1F.

Page99

The Trigger Algorithm of 1F Event


Measurement
Quantity

Cell 1
1F Trigger
Delay Time
Absolute
Threshold T1f

Hysteresis
H1f /2

Time
Reporting
event 1F

Page100

Key Parameters of Event 1F


INTRAABLTHDFOR1FECNO
Parameter name: 1F event absolute EcNo threshold
The recommended value is -24 dB
INTRAABLTHDFOR1FRSCP
Parameter name: 1F event absolute RSCP threshold
The recommended value is -115 dBm

Page101

Key Parameters of Event 1F


HYSTFOR1F
Parameter name: 1F hysteresis
The recommended value is 8, namely 4 dB
TRIGTIME1F
Parameter name: 1F event trigger delay time
The recommended value is D640, namely 640 ms

Page102

Blind Handover Decision


After receiving event 1F of best cell from UE, the RNC

would check if blind handover neighbor is configured for


the cell.
If multiple blind handover neighbors are configured, the
RNC would perform blind handover to the target cell
with the highest priority

Page103

Key Parameters of Blind Handover


BLINDHOFLAG
Parameter name: Blind handover flag
The default value is FALSE
BLINDHOPRIO
Parameter name: Blind handover Priority
The value is set according to actual situation.

Thank you
www.Operator.com

Anda mungkin juga menyukai