VC
Vacuum Contactor
>
>
Features
| Superior Switching Performance
Switching a vacuum makes for rapid breaking.
Rapid build-up of the dielectric strength ensures safety breaking.
The fuse mounted type also provides for protection against short-circuit currents.
| Optimum Design
Optimized structure and mechanism complement frequent switching.
| Low Surge
Special WCAg contact limits the chopping current up to 1A to protect the load from high surge.
| High Reliability
Rigid insulation frame and operating mechanism offer high reliability, especially for safety and quality assurance.
| Customer Convenience
Light weight and compact size enable easy installation with high efficiency in space.
Optimum design makes maintenance convenient.
>
>
| Latched Type
Latched type keeps the closing condition without the supply of power, so it is suitable for the system which has unstable
power or the load which requires automatic closing with power.
With the separate tripping circuit, DC control voltage is recommended for stable power supply. When AC control voltage is
used, the CTD(condesor trip device) should be installed.
[ 3.6/7.2kV M1 cradle ]
6
5
7
8
1
[ Latched type]
ON/OFF indicator
Draw-out mechanism
Counter
Fuse
Control jack
Fuse holder
HCA Type
>
> Ratings
| Qualified Standard & Approval
Standard
- IEC 60470
- NEMA ICS 3
Approval
- KR/Korea
- GL/Germany
- LR/U.K
- NK/Japan
Type
Operating
method
Draw-out type
B Without fuse holder
D With single fuse holder
H With double fuse holder1)
Continuously energized
32C
34C
62C
64C
82C
84C
32C
34C
62C
64C
82C
84C
Latched
32L
34L
62L
64L
82L
84L
32L
34L
62L
64L
82L
84L
3.6
7.2
12
3.6
7.2
12
3.3
6.6
11
3.3
6.6
11
50/60
200
400
200
400
400
200
400
400
200
400
45
60
75
45
60
75
16
20
28
16
20
28
AC3
Utilization category
AC4
Short-time
current
(kA)
AC3
AC4
4kA (O-3min-CO-3min-CO)
Breaking capacity
1 sec
6.3
6.3
6.3
6.3
6.3
6.3
30 sec
2.4
2.4
2.4
2.4
2.4
2.4
1,000
1,000
1,000
1,000
1,000
1,000
250
250
250
250
250
250
Continuously energized
(1,000 times)
300
AC110/220, DC110/220
Auxiliary contact
2a2b2)
Motor (kW)
Applicable
load capacity
200
Impulse (kV)
Mechanical
life time
200
5a5b
750
1,500
1,500
3,000
3,000
6,000
750
1,500
1,500
3,000
3,000
6,000
Transformer (kVA)
1,000
2,000
2,000
4,000
4,000
8,000
1,000
2,000
2,000
4,000
4,000
8,000
Condensor (kVAR)
750
1,200
1,500
2,000
3,000
4,000
750
1,200
1,500
2,000
3,000
4,000
F 21
F 22
F 61
B 38 3)
B 41 3)
B 80 4)
A 30
A 32
A 68
D 40 3)
D 43 3)
D 83 4)
J 33
J 35
H 433)
H 463)
VC
>
>
Vacuum Contactor
Technical Data
| Operating Time and Current
Continuously
energized
type
3.6/7.2kV
12kV
3.6/7.2kV
12kV
DC110V
2.5
10.0
1.0
3.0
DC220V
1.6
10.0
0.7
3.0
AC110V
2.0
10.0
0.8
3.0
AC220V
1.0
10.0
0.5
3.0
DC110V
2.7
10.0
Opening
current (A)
Closing
time (ms)
Opening
time (ms)
Max. 80
Max. 40
Max. 80
Max. 40
Max. 120
Max. 25
Max. 120
Max. 25
5.0
-
Latched
type
DV220V
1.7
10.0
AC110V
1.9
10.0
4.0
3.5
-
AC220V
1.2
3.0
10.0
| Control Voltage
Closing
AC110V
5A
Opening
AC220V
2A
[ CLOSED condition ]
[ Continuously energized ]
[ Latched ]
Latch device
HCA Type
[ OPEN condition ]
[ Continuously energized ]
[ Latched ]
Latch device
Closing coil
Main shaft
Resistance
Moving core
Charging spring
Latch device
Opening spring
Vacuum interrupter
Insulation frame
Pressing plate
Auxiliary switch
Closing
When the closing coil( ) is energized, the moving core( )
moves to the closing coil and compresses the opening
spring( ). At the same time the pressing plate( ), which is
fixed on the main shaft( ), pushes the charging spring( ),
so the movable stem of the vacuum interrupter( ) is moved
up to make the CLOSED condition.
Continuously energized type: When the moving core( )
moves, the auxiliary switch( ) leads the control power to
resistance( ) and reduces the current of the closing coil( ).
Latched type: When the contactor is closed, the latch device
( ) of the contactor fixs the moving core( ) mechanically
and keeps the closed condition. Then the control power is
removed.
Rear shaft
Opening
Continuously energized type: When the closing coil( ) is
de-energized by the OFF signal, the opening spring( ) is
released to the OPEN condition.
Latched type: When the opening coil is energized by the
OFF siginal or the opening button is pushed, the latch
device( ) is released and the opening spring( ) lets the
moving core( ) move to the OPEN condition.
During a power failure, the trip button or condensor trip
device(CTD) of the latched type also enable the opening of
the contactor.
VC
>
>
Vacuum Contactor
Technical Data
| Interlock Function
Case
When the
contactor
is closed,
Principle
Release
Interlock Mechanism
Incorrect position
Closing coil
Closing coil
Moving core
Moving core
Interlock pin 1
Interlock pin 1
Cradle
Cradle
Interlock Release
E1/F1 cradle
M1 cradle
Stopper
Interlock lever
Draw-in/out handle
HCA Type
| Fuse
without Fuse Holder Type
The breaking current of without fuse type is limited, so a circuit breaker should be installed in the upper circuit of the line side.
In the case of draw-out types, the fuse holder connection part is replaced by a bus-bar. When it is required, the fuse holder
can be installed under our instruction.
Fuse Selection
3Motor (kW)
Load
Applicable
fuse current
20A
30A
40A
50A
63A
80A
100A
125A
160A
200A
250A
315A
355A
2160A
2200A
2250A
3.3kV
90
100
125
160
200
275
315
400
500
600
500
650
750
3Transformer (kVA)
6.6kV
160
200
250
330
400
550
650
830
1,000
1,200
1,000
1,300
1,500
3.3kV
50
80
100
125
160
200
250
315
400
500
630
750
900
800
1,000
1,250
6.6kV
100
160
200
250
315
400
500
630
800
1,000
1,250
1,500
1,800
1,600
2,000
2,500
3Condenser (kVAR)
3.3kV
30
50
75
100
125
150
200
250
300
375
500
600
700
600
750
1,000
6.6kV
60
100
150
200
250
300
400
500
650
750
1,000
1,200
1,400
1,200
1,500
2,000
- This table is based on SIBA catalogue, and is for the 3-phase motor with starting time max. 15 seconds and starting frequency 2 times per hour.
- SIBA recommends choosing the next highest voltage range in the condensor load.
- Please contact us for the further details of application data.
| Operating Condition
Altitude : less than 1,000m A.S.L(above sea level)
Multiply the impuIse and the withstand voltage in accordance with the following correction factor (k) for high locations.
Applied altitude
Correction factor (k)
1,000m
1.0
1,500m
1.05
2,000m
1.1
2,500m
1.15
3,000m
1.2
40
1.0
45
1.05
50
1.1
55
1.15
60
1.2
Special conditions
Please contact us for information on special cases like seashore use, corrosive chemical environments, and so on.
VC
>
>
Vacuum Contactor
Accessories
| Standard Accessories
| Additional Option
Position switch
Electrical Interlock
Potential Transformer
Condensor Trip Device
When the latched type vacuum contactor is
used in AC control voltage, the condensor
trip device should be installed inside the
3.6/7.2kV contactor as an internal option.
For 12kV contactor, it should be installed
in switchgear.
Order code
HCAS0012
HCAS0013
AC110V
AC220V
DC145V
DC290V
Ordinary current
DC2A
Frequency
50/60Hz
Applied standard
Terminal Connection
1,2: Input power(AC) / 5,6: Closing power(DC) / 5,7: Trip power
| Vacuum Checker
The portable vacuum checker can be
used to check the condition of
vacuums.
Order code
Rated input voltage
Rated out-put voltage
Dimension
Weight
10
HAFS-VC9
AC200/220V
AC11/22kV
W200 x L350 x H176mm
22kg
HCA Type
>
> Circuit Diagrams
3.6/7.2kV
DC Control
for Fixed Type
Close/
Open
Close
Open
Vzb
Vza
X
Vzb
Aux.
Switch
CC
Aux.
Switch
CC
CC
TC
Control Jack
Control Jack
[ Continuously energized ]
[ Latched ]
3.6/7.2kV
AC Control
for Fixed Type
Close/
Open
Open
Close
Vzb R
Aux.
Switch
CC
Vzb
Vza
CTD
CC
Aux.
Switch
X
CC
TC
Control Jack
Control Jack
[ Latched ]
[ Continuously energized ]
12kV
Close
Close
40
9 11 13 15 17 19 21 23 25 27
11
14
Service
1
CC CC
14
Service
VZb
SCU
3
10 12 14 16 18 20 22 24 26 28
Close/Open
Aux. Switch
9 11 13 15 17 19 21 23 25 27
Aux.
Switch
CC CC
SCU
S9
14
Test
Aux.
Switch
13
S8
S9
12
Test
3
13
13
S8
Open
40
TC
10 12 14 16 18 20 22 24 26 28
Close/Open
[ Continuously energized ]
Aux. Switch
[ Latched ]
Option
29
23
S8
43
S9
24
30
Potential
Transformer
1set
43 45
33
Test
Position
44
34
44
Connection
Switch
[ 3.6/7.2kV ]
[ 12kV ]
Vza, Vzb: Control Switch R: Resistor CC: Closing Coil Aux. Switch: Auxiliary Switch X: Relay
TC: Trip Coil CTD: Condensor Trip Device SCU: Control Unit S8, S9: Internal Position Switch
11
VC
>
>
Vacuum Contactor
Dimensions
(Unit: mm)
120
35
6
120
120
Terminal
12.5
OFF
11
25
245
ON
15
385
35
120
27
12
MADE IN KOREA
Mounting Holes
180
204
Mounting Holes(4-13)
340
Dimension Y
215
408
200A
400A
25
32
(Unit: mm)
358
120
258
Terminal
120
20
160
610
12.5
11
A
ON
268
OFF
MADE IN KOREA
Dimension A
Mounting Holes(4-13)
470
59
Mounting Holes
314
62
510
50
200A
400A
25
32
(Unit: mm)
120
358
258
Terminal
120
680
20
12.5
13
160
ON
OFF
268
MADE IN KOREA
Mounting Holes(4-13)
470
510
12
59
62
Mounting Holes
314
50
Dimension A
200A
400A
25
32
HCA Type
(Unit: mm)
120
120
475
600
160
Terminal
ON
286
20
OFF
MADE IN KOREA
Mounting Holes
555
125
Mounting Holes(4-13)
340
518
13
32
120
48
752
(Unit: mm)
120
358
258
120
600
630
160
Terminal
ON
286
20
OFF
11
13
120
32
MADE IN KOREA
Mounting Holes(4-13)
340
520
125
Mounting Holes
555
48
752
13
VC
>
>
Vacuum Contactor
Dimensions
(Unit: mm)
120
120
ON
20
475
600
160
Terminal
286
OFF
MADE IN KOREA
Mounting Holes
555
125
Mounting Holes(4-13)
340
518
13
32
120
48
752
(Unit: mm)
120
120
358
258
20
600
600
160
Terminal
13 120
32
ON
286
OFF
MADE IN KOREA
Mounting Holes(4-13)
340
11
125
Mounting Holes
555
48
800
518
(Unit: mm)
120
358
258
120
ON
286
OFF
MADE IN KOREA
Mounting Holes(4-13)
340
520
14
11
125
Mounting Holes
555
800
48
20
600
160
700
Terminal
13
32
120
HCA Type
(Unit: mm)
120
50
131.5
Terminal
61
46
730
210
120
40
120
13
120
100
268
173
630
Mounting Holes(4-13)
360
20
148
Mounting Holes
500
808
525
1042
(Unit: mm)
131.5
730
210
Terminal
120
660
120
13
120
100
MADE IN KOREA
268
173
40
61
120
46
120
Mounting Holes(4-13)
360
20
148
Mounting Holes
500
808
525
1042
(Unit: mm)
120
131.5
61
46
760
730
210
120
35
120
13
120
100
268
173
765
Terminal
Mounting Holes(4-13)
360
525
20
148
Mounting Holes
500
808
1042
15
VC
>
>
Vacuum Contactor
Dimensions
(Unit: mm)
Terminal
165
165
38
15
84
845
210
6
835
200
80
72
200
50
151.8
15
40
20
35
165
385
Control Plug
1000
165
13
Earthing Switch
(Unit: mm)
323
278
20
Mounting Holes
410
150
11
13
502.2
Mounting Holes
275
137.5
150
MADE IN KOREA
444
[ front ]
[ side ]
[ top ]
(Unit: mm)
500
12
500
150
150
Mounting Holes
210
350
746
758
193
15
500
334
530
638
Mounting Holes
547
[ front ]
[ side ]
[ top ]
16
139
MADE IN KOREA
HCA Type
(Unit: mm)
150
784
772
784
289
Terminal
150
3
1
346
35
40
MADE IN KOREA
Mounting Holes
400
Mounting Holes
800
125
4-13
599
1005
70
(Unit: mm)
237
150
50
30
930
784
345
Terminal
77
150
34
318
13
3
Mounting Holes
400
125
4-13
599
17
MADE IN KOREA
Mounting Holes
600
828
1064
17
VC
>
>
Vacuum Contactor
Order Information
HCA
Code
Model
Name
HCA
HCA
6
Code
4
Rated
Voltage
3
6
7.2kV
12kV
3.6kV
Code
2
4
C
Rated
Current
200A
400A
Structure
Code
Operating
Method
Code
Continuously
Energized
F
A
Single
Latched
J
B
Double
Single
Double
Contactor
Fuse Holder
Code
Control
Voltage
1
2
DC110V
3
4
AC110V
DC220V
AC220V
Latched
Category
Code
Specification
HCA32CF 4000000
3.6kV
HCA62CF 4000000
7.2kV
HCA82CF 4000000
12kV
HCA32CD 4F16000
3.6kV
HCA62CD 4F16000
7.2kV
HCA82CD 4F1600A
12kV
HCA32CD 4M16000
3.6kV
HCA62CD 4M16000
7.2kV
HCA82CD 4M1600A
12kV
HCA34CF 4000000
3.6kV
HCA64CF 4000000
7.2kV
HCA84CF 4000000
12kV
HCA34CD 4F16000
3.6kV
HCA64CD 4F16000
7.2kV
HCA84CD 4F1600A
12kV
HCA34CD 4M16000
3.6kV
HCA64CD 4M16000
7.2kV
HCA84CD 4M1600A
12kV
200A
200A
200A
Code
Specification
Fixed type
without fuse holder,
AC220V,
No cradle,
No fuse holder
HCA32LF 4000000 AF
3.6kV
HCA62LF 4000000 AF
7.2kV
12kV
Draw-out type
with single fuse holder,
AC220V,
F1 cradle,
No fuse
HCA32LD 4F16000 AF
3.6kV
HCA62LD 4F16000 AF
7.2kV
12kV
Draw-out type
with single fuse holder,
AC220V,
M1 cradle,
No fuse
HCA32LD 4M16000 AF
3.6kV
HCA62LD 4M16000 AF
7.2kV
12kV
Fixed type
without fuse holder,
AC220V,
No cradle,
No fuse holder
HCA34LF 4000000 AF
3.6kV
HCA64LF 4000000 AF
7.2kV
12kV
Draw-out type
with single fuse holder,
AC220V,
F1 cradle,
No fuse
HCA34LD 4F16000 AF
3.6kV
HCA64LD 4F16000 AF
7.2kV
12kV
Draw-out type
with single fuse holder,
AC220V,
M1 cradle,
No fuse
HCA34LD 4M16000 AF
3.6kV
HCA64LD 4M16000 AF
7.2kV
12kV
200A
Fixed type
without fuse holder,
AC220V,
No cradle, No fuse holder,
AC220V CTD
200A
Draw-out type
with single fuse holder,
AC220V,
F1 cradle, No fuse,
AC220V CTD
200A
Draw-out type
with single fuse holder,
AC220V,
M1 cradle, No fuse,
AC220V CTD
400A
Fixed type
without fuse holder,
AC220V,
No cradle, No fuse holder,
AC220V CTD
400A
Draw-out type
with single fuse holder,
AC220V,
F1 cradle, No fuse,
AC220V CTD
400A
Draw-out type
with single fuse holder,
AC220V,
M1 cradle, No fuse,
AC220V CTD
VC
400A
400A
400A
18
V2
HCA Type
M1
Code
6000
Cradle
Code
00
E1
0000
6000
F1
M1
T1
without Shutter
with Metal Shutter and Bushing
with Metal Shutter, Bushing
and Earthing Switch
AMAP
Fuse Application
Fuse Holder
Fuse Specification
Single
up to 250A, 192mm
600A
Single
3.6/7.2kV 315/355A,
12kV, 292mm
600B
600C
Double
3.6/7.2kV, 192mm
Single
442mm
Code
AE
BE
AF
BF
AL
BL
AM
BM
AP
BP
T1
T3
T4
T6
Additional Option
CTD, AC110V
CTD, AC220V
Electrical Interlock
Fuse Melting Detector
Position Switch
Potential Transformer, 3.6kV x 1EA
Potential Transformer, 7.2kV x 1EA
Potential Transformer, 3.6kV x 2EA
Potential Transformer, 7.2kV x 2EA
Application
Mounting
3.6/7.2kV
12kV
Latched type,
3.6/7.2kV AC control
Inside
12kV
of
3.6/7.2kV
Draw-out type contactor
12kV
3.6/7.2kV
for Fuse
12kV
3.6/7.2kV
Draw-out type Cradle
12kV
3.6/7.2kV
All
Inside
of
contactor
| Spare Parts
Code
Specification
Category
Code
Specification
Category
HCAS0001
Counter (5 digit)
HCAS6032
HCAS0002
HCAS6040
HCAS0003
HCAS6050
HCAS0004
HCAS6063
HCAS0005
HCAS6080
HCAS0006
HCAS6100
HCAS0007
HCAS6125
HCAS0008
HCAS6160
HCAS0009
HCAS6200
HCAS0011
HCAS6250
HCAS0012
HCAS6315
HCAS0013
HCAS6355
HCAS0015
HCAS7006
HCAS0016
HCAS7010
HCAS0019
HCAS7016
HCAS0020
HCAS7020
HCAS0018
HCAS7025
HCAS0021
HCAS7032
HCAS0022
HCAS7040
HCAS0023
HCAS7050
HVC00704
HCAS7063
VC
V8
HVC01204
HCAS7080
HCAS6006
HCAS7100
HCAS6010
HCAS7125
HCAS6020
HCAS7160
HCAS6025
HCAS7200
VC
V8
- 442mm fuse is applicable to 12kV vacuum contactor, but not supplied by HHI.
1) 2EA is required for 1set of vacuum contactor.
2) 6EA is required for 1set of vacuum contactor.
19
www.hyundai-elec.com
Head Office
Seoul
(Sales & Marketing)
Orlando
3452 Lake Lynda Drive, Suite 170, Orlando, Florida 32817, U.S.A.
Tel: 1-407-249-7350
Fax: 1-407-275-4940
New Jersey
London
Tokyo
8th Fl., Yurakucho Denki Bldg.1-7-1, Yuraku-cho, Chiyoda-gu, Tokyo, 100-0006, Japan
Tel: 81-3-3212-2076, 3215-7159
Fax: 81-3-3211-2093
Osaka
I-Room 5th Fl. Nagahori-Plaza Bldg. 2-4-8, Minami Senba, Chuo-Ku, Osaka, 542-0081, Japan
Tel: 81-6-6261-5766, 5767
Fax: 81-6-6261-5818
Dubai
Unit 205, Level 2, Burj Dubai Square Building No.4, Sheikh Zayed Road, P.O.Box 252458
Tel: 971-4-425-7995
Fax: 971-4-425-7996
Sofia
Yangzhong
No.9 Xiandai Road, Xinba Scientific and Technologic Zone, Yangzhong, Jiangsu, P.R.C. Zip: 212212, China
Tel: 86-511-8842-0666, 0212
Fax: 86-511-8842-0668, 0231