Anda di halaman 1dari 139

XINXING

PIPES

Product Technical Manual

The brochure is printed on


environmentally friendly paper

XINXING
PIPES

Product
Technical Manual

WORLD'S LARGEST DUCTILE IRON PIPE MANUFACTUER

Contents
Company Profile

Chapter I, Ductile Iron Pipe Joint


and Anti-corrosion Solution
Chapter II Manufacturing Process
and Quality Control System
Chapter III. Requirements
for Storage and Transportation
of Ductile Iron Pipe
Chapter IV.Engineering
Design of Water Supply
& Drainage Pipeline
Chapter V Construction,
Installation and Acceptance of
Ductile Iron Pipe
Chapter VI Xinxing Ductile
Iron Fittings and Accesseries
Chapter VII Valves for
Water Supply and Drainage Pipeline

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

Company Profile
Xinxing Ductile Iron Pipes Co., Ltd., as a subsidiary of Xinxing Cathay International Group Co.,Ltd, adheres
to the orientation of science and technology, environmental protection, quality and efficiency. At present,
it has grown into a trans-regional and multi-industrial enterprise group integrating such wide industries as
ductile iron pipe, steel and machinery, as well as various areas such as scientific research, production and
trade. In 1997, Xinxing was listed on the Shenzhen Stock Exchange of China and has been selected as the
Top 50 Most Promising Listed Companies for 8 consecutive years since then. Xinxing is primarily engaged
in the centrifugal casting ductile iron pipes and fittings, steel smelting and rolling processing, special steel
pipes, and foundry products, etc. At present, it has grown into an integrated processing enterprise with the
annual output of more than 10 million tons of metal products, including eight major series, i.e. Xinxing ductile
iron pipes, Xinxing steel, Xinxing special steel pipes, Xinxing gratings, Xinxing castings, Xinxing steel-plastic
composite pipes, with the annual output of 8.0 million tons of steel, 1.8 million tons of ductile iron pipes,
40,000 tons of ductile iron fittings, 180,000 tons of special steel pipes, 3,000,000 m steel-plastic composite
pipes and 80,000 tons of steel gratings. It has established production bases in Handan of Hebei, Wuhu of
Anhui, Bazhou of Xinjiang, Huangshi of Hubei, Taojiang of Hunan, and Chongzhou of Sichuan, etc.

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Co., Ltd. is the

fields.

worlds largest supplier of ductile iron pipes and

Xinxing Ductile Iron Pipes Co., Ltd. has

fittings. The domestic market share of its pipe

passed British Lloyds certification of

products is about 45%, and the export ratio is

ISO9001 quality management system,

about 30%. The products have been exported

ISO14001 environmental management

to more than 110 countries and regions around

system, GB/T28001 occupational health

the world, including Middle East, America,

and safety management system, and GB/

Africa, Europe, Southeast Asia, etc.

T19022 measurement management system.

Xinxing plastic-steel composite pressure pipe is

Ductile iron pipes and fittings have passed

the tubular product formed by extrusion molding

Italian BV and Chinese BV certification for

with the intermediate layer made of welded

standards such as BSEN545, BSEN598,

steel pipe, the inner and outer layers made of

ISO2531, KSD4311, ABNT NBR 7675,

polyethylene, the nominal diameter of DN20 ~

ISO7186, ISO8179-1, ISO8179-2, ISO4179,

DN200, and the nominal pressure PN of 1.25

NF A 48-851, BSEN15189 and BSEN15655;

~ 2.5MPa. The product can be widely used

flat steel and wire rods have passed CE

in building water supply, telecommunications,

certification by British Lloyd's Register

e l e c t r i c p o w e r, p e t r o l e u m , c h e m i c a l ,

Quality Assurance.

pharmaceutical, food, mining, gas and other

Xinxing Ductile Iron Pipes Technical Manual

01

Chapter I ,
Ductile Iron
Pipe Joint and
Anti-corrosion
Solution

02

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

03

1.1 Ductile iron pipe wall thickness 7


1.2 T-type Joint ductile iron pipe 9
1.2.1 Joint description
1.2.2 Technical parameters
1.3 XT2-type joint ductile iron pipe 11

Chapter I ,
Ductile Iron
Pipe Joint and
Anti-corrosion
Solution

1.3.1 Joint description


1.3.2 Technical parameters
1.4 TF Self-anchored Joint ductile iron pipe

13

1.4.1 Joint description


1.4.2 Technical parameters
1.5 Xanchor self-anchored joint ductile iron pipe 15
1.5.1 Joint description
1.5.2 Technical parameters
1.6 Flange (welding) joint ductile iron pipe 17
1.6.1 Joint description
1.6.2 Technical parameters
1.7 XTJ Ductile Iron Jacking Pipe

18

1.7.1 Product description


1.7.2 Technical parameters
1.8 External anti-corrosion coating 21
1.8.1 Soil aggressivity
1.8.2 Selection of external coating
1.9 Internal lining 32
1.9.1 Evaluation on aggressivity of water for ductile iron pipes
1.9.2 Materials in contact with potable water
1.9.3 Lining Selection
1.9.4 Cement mortar lining
1.9.5 Cement mortar lining +epoxy seal coats
1.9.6 Polyurethane lining
1.9.7 Ceramic epoxy lining
1.10 Coating repairment 47
1.10.1 Repairment of zinc coating/Zn-Al rare earth alloy coating
1.10.2 Repairment of PU coating
1.10.3 Repairment of cement mortar lining
1.10.4 Repairment of cement lining with epoxy seal coats
1.10.5 Repairment of ceramic epoxy(PU)lining

04

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

05

Ductile iron material features similar mechanical properties with carbon steel, such as high mechanical
strength and good ductility, and the same anti-corrosion performance as cast iron. Therefore, ductile iron

1.1 Ductile iron pipe wall thickness

pipe has gradually become one of the most secure and reliable pipes in the water supply and drainage area

Xinxing ductile iron pipes can be graded by the wall thickness class coefficient K or pressure class C.

throughout the world.

Executive standards are as following:

Xinxing Ductile Iron Pipes Co., Ltd. provides ductile iron pipe products ranging from DN80 ~ DN2600 in

ISO 2531/ISO 7186

accordance with ISO2531/7186 or EN545/598. Meanwhile, it can provide the most appropriate joints and

EN 545/EN 598

internal and external anti-corrosion solutions according to the pipeline laying and using conditions. For

GB/T 13295, GB/T 26081 and other related standards for ductile iron pipes

details, see the table below:

Note: The wall thickness class coefficient K (or pressure class C) shall be specified in the agreement
between the supplier and the purchaser.

Table 1 Xinxing Ductile Iron Pipes Joint and Anti-corrosion Solutions


Anti-corrosion Coating
Joint Type

Flexible joint

Self-anchored joint
Rigid

Specification Range

Internal lining

External Coating

Cement mortar lining

Zinc + high chlorinated

Cement mortar lining +

polyethylene finishing

Graded by wall thickness class coefficient K


The nominal wall thickness of ductile iron pipe is calculated as per the function of nominal diameter DN, and
the calculation formula is as following:

T-type joint

DN80~2000

XT2-type joint

DN80~2600

TF joint

DN80~1200

epoxy seal coats

layer

Xanchor joint

DN1400~2000

Polyurethane lining

Zinc+epoxy coating

Where: enom Nominal wall thickness, mm

Welded flange joint

DN80~2000

Ceramic epoxy linning

Polyurethane coating

DN nominal diameter, mm;

XTJ jacking pipe

enom= K(0.5+ 0.001DN)

KWall thickness class coefficient, selected from a series of whole numbers ...9,10,11,12...

DN250~2000

The minimum nominal wall thickness of centrifugal casting ductile iron pipe is 6mm, and the minimum wall
thickness of non-centrifugal casting ductile iron pipe and fittings is 7 mm; the tolerance on thickness for
pipes and fittings is shown in the table below.
Table 2 Limit Deviation on Nominal Wall Thickness for Pipes and Fittings (Unit: mm)
Type of casting
Pipes centrifugally cast

Pipes non-centrifugally cast and fittings

Limit Deviation

-1.3

-(1.3+0.001DN)

-2.3

-(2.3+0.001DN)

Graded by pressure class C


When the ductile iron pipes are classified by pressure class C, its allowable operating pressure is expressed
by Arabic numerals prefixed by the letter C, and its unit is bar. Minimum wall thickness of the pipe is
calculated by the allowable operating pressure.The formula is as following:

06

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

07

emin=

Where

1.2 T-type joint ductile iron pipe

PFA SF DE
20Rm+ PFASF

1.2.1 Joint description

emin Minimum wall thickness of pipe, mm;

Spigot Socket Rubber Gasket

PFAAllowable operating pressure, bar


SFSafety factor of PFA (SF = 3);
DEExternal diameter of pipe, mm
RmMinimum tensile strength of ductile iron
pipe, in MPa(Rm=420 MPa);
For pipes centrifugally cast, the minimum wall thickness

Figure 1 T-type joint structure

shall not be less than 3mm; for pipes non-centrifugally cast,


the minimum wall thickness shall not be less than 4.7 mm;

Sealing principle

the tolerance on thickness for pipes is shown in table 3.

Structure of T-type joint is shown in Figure 1. During joint installation, the external spigot is extruded on

Specification range for preferred pressure class of C-class

the rubber ring inside the socket.The compression deformation can generate a certain degree of contact

pipes are shown in Table 4.

pressure. And it is the so-called self-sealing action of the rubber ring that keeps the joint tight. The selfsealing effect means, when the rubber ring is under the fluid pressure, the actual contact pressure on the
rubber ring is the sum of the contact pressure of the pre-compressed rubber ring and the new contact

Table 3 Tolerance on Wall Thickness For C-Class Pipes


and Fittings (Unit: mm)
Type of casting

Tolerance

Pipes Centrifugally Cast

+1.3+0.001DN

Pipes Non-centrifugally
Cast and fittings

+2.3+0.001DN

pressure on the rubber ring brought by the fluid pressure. Since the contact pressure is higher than the fluid
pressure, so that the joint is well tightened.
Joint features
The joint features simple structure, easy installation and sound sealing performance. The positioning of
sealing ring and deflection of joint are taken into consideration during socket structure design. By controlling
the insertion depth of the spigot, the joint can have certain axial flexibility. Therefore this type of joint is able
to adapt to certain foundation settlement, while long-distance deflection of pipeline can be achieved through
its deflection angle . Joint deflection installation is shown in Figure 2.

Table 4 Specification Range for Preferred Pressure Class


of C-class Pipes

The rubber ring consists of two parts, i.e. the hard rubber and soft rubber. The hard rubber can support and
align the pipe joints, and greater thrust is needed during installation.

Specification Range

Preferred Pressure Class

DN80~DN300

C40

T-type Joint is unable to prevent pipe slippage, therefore the concrete

DN350~DN600

C30

blocks to resist the axial forces should be set at the bend of pipeline, or

DN700~DN2000

C25

certain length of self-anchored joint ductile iron pipe should be laid.


Application Field

Figure 2 Joint Deflection

Pressure/non-pressure water supply (potable water, sewage, etc.) pipeline;


Underground/overground laying, and the pipe laying slope does not exceed 20% (overground laying) or
25% (under ground laying).
Installation method
Please refer to 5.2.2 T-type joint ductile iron pipe installation

08

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

09

1.2.2 Technical parameters

1.3 XT2-type joint ductile iron


pipe

The main technical parameters of T-type joint ductile iron pipe are shown in Figure 3 and Table 5:

enom

1.3.1 Joint description

DE

Spigot Socket Rubber Gasket

Lu
Figure 3 T-type joint ductile iron pipe

Table 5 Technical Parameters of T-type Joint Ductile Iron Pipe


K9

C-Class

DE

Lu

(mm)

(mm)

(mm)

()

(mm)

80

98

140

85

100

118

163

88

125

144

190

91

150

170

217

94

200

222

278

100

6.3

62

4.7

250

274

336

105

6.8

54

5.5

300

326

393

7.2

49

6.2

350

378

448

7.7

45

6.3

400

429

500

8.1

42

6.5

450

480

540

8.6

40

6.9

500

532

604

38

7.5

600

635

713

9.9

36

8.7

700

738

824

150

10.8

34

8.8

800

842

943

160

11.7

32

9.6

Application Field

900

945

1052

175

12.6

31

10.6

The same with T-type joint (see 1.2.1 Joint

1000

1048

1158

185

13.5

30

11.6

description - Application Field).

1100

1152

1267

200

14.4

29

12.6

1200

1255

1377

215

1400

1462

1610

239

1500

1565

1710

250

1600

1668

1820

262

18.9

1800

1875

2050

300

20.7

2000

2082

2266

319

22.5

DN

110

120

enom(mm)

PFA
(bar)

64

6000

15.3

17.1
6000/8150

18

enom(mm)

27

26

Figure 4 XT2-type joint

(bar)

4.4

Sealing principle

4.4

Structure of XT2-type Joint is shown in

4.5
4.5

28

PFA

13.6

Figure 4. Its sealing principle is similar with


40

that of T-joint (see 1.2.1 Joint description Sealing principle);


Joint features
Similar with T joint. As the sealing ring

30

of XT2-type joint adopts the lip-shaped


structure, the pipe is subject to less rubber
seal resistance during installation;

25

Installation method

15.7

The same with the T-type joint, please

16.7

refer to 5.2.2 T-type joint ductile iron pipe

17.7

installation.

19.7
21.8

1 C-Class pipe of preferred pressure class complying with ISO2531-2009

10

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

11

1.4 TF Self-anchored joint ductile iron pipe

1.3.2 Technical parameters:


The main technical parameters of XT2-type joint ductile iron pipe are shown in Figure 5 and Table 6.

enom

1.4.1 Joint description


Welded Bead
Rubber Gasket

DE

Locking Ring
Gland
Bolts and Nuts

Lu

Figure 5 XT2-type Joint Ductile Iron Pipe


Table 6 Technical Parameters of XT2-type Joint Ductile Iron Pipe

DN

DE
(mm)

D
(mm)

P
(mm)

80

98

140

92.5

100

118

163

94.5

150

170

217

100.5

200

222

278

250

274

336

300

326

393

350

378

400

()

Lu
(mm)

K9
enom(mm)

C-Class
PFA
(bar)

6
5

64

enom(mm)

PFA
(bar)

Figure 6 TF self-anchored joint structure

Joint structure

4.4

As shown in Figure 6, TF self-anchored joint adopts the T-joint sealing structure. Compared with T-joint, it

4.4

adds a welded bead on spigot, an open-end locking ring, a special gland and connecting bolts to provide the

4.5

40

joint with good anti-slippage performance. The locking ring and the gland can slide between each other, so

6.3

62

4.7

6.8

54

5.5

Working principle

107.5

7.2

49

6.2

The axial thrust forces generated at the bending places and tees of the pressure pipeline will cause the

448

110.5

7.7

45

6.3

socket and spigot components to have relative displacement. Axial stress generated at spigot is passed on

429

500

112.5

8.1

42

6.5

450

480

540

115

8.6

40

6.9

500

532

604

117.5

38

7.5

600

635

713

122.5

9.9

36

8.7

700

738

824

10.8

34

8.8

800

842

943

11.7

32

9.6

900

945

1052

12.6

31

10.6

1000

1048

1158

157.5

13.5

30

11.6

1200

1255

1377

167.5

15.3

1400

1462

1610

245

17.1

1600

1668

1820

275

1800

1875

2050

285

2000

2082

2266

290

2200

2288

2482

317

24.3

2400

2495

2702

336.5

26.1

2600

2702

2921

353

27.9

105.5

147.5

6000
3.5

18.9

1.8
6000/8150

20.7
22.5

28

27
26

25

30

17.7

to the socket through welded bead, locking ring, gland and connecting bolts, enabling the transmission of
axial stress to equip the joint with good anti-slippage performance. When the friction between the restrained
pipeline and its surrounding soil is greater than the axial stress generated inside the pipe, safe operation of
the pipeline can be guaranteed, thus avoiding the set-up of concrete block.
Application Field
In the following conditions, certain length of pipeline with TF-joints could be applied in order to prevent
pipeline slippage:
1. Places such as bends, tees, reducers and plugs, etc;

13.6
15.7

that the joint has certain axial stretching and deflection capability.

2. When the pipeline laying slope exceeds 20% (laying overground) or 25% (laying underground);
25

3. When it is uneconomical (such as large-diameter high-pressure pipelines, etc.) or unable to set concrete

19.7

buttress, for example:

21.8

A. The construction site is too narrow; there is no space to set up specified concrete block;

23.8

B. Construction schedule is tight;

25.8

Installation method

27.9

Please refer to5.2.5 Self-anchored joint installation

1 C-Class pipe of preferred pressure class complying with ISO2531-2009

12

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

13

1.4.2 Technical parameters

1.5 Xanchor self-anchored joint ductile iron pipe

The technical parameters of TF self-anchored joint ductile iron pipe are shown Figure 7 and Table 7.

1.5.1 Joint description

DE

enom

Front Stopper
Rear Stopper
Rubber Supporter
Rubber Gasket

Lu

Figure 7 TF Self-anchored Joint Ductile Iron Pipe

Figure 8 Xanchor Self-anchored Joint structure

Table 7 Technical Parameters of TF Self-anchored Joint Ductile Iron Pipe

Joint structure
K9

Xanchor self-anchored joint, as shown in Figure8, adopts the sealing structure of XT2 joint. Its socket is

DE

DGland

(mm)

(mm)

80

98

243

85

is where the sealing ring is set, and the stopper chamber is used to house the self-anchored components

100

118

264

88

which are comprised of the front blocks, the rear blocks, the supporting ring and welded bead.

150

170

321

94

200

222

375

100

250

274

433

105

300

326

509

350

378

567

400

429

591.6

450

480

675

500

532

700

600

635

811

700

738

935

800

842

900

DN

P(mm)

()

Lu(mm)

enom(mm)

6.3

PFA1(bar)

30

essential mechnism is to effectively prevent slippage through the two rows of rigid blocks . Meanwhile,

7.2

the circular sliding of the front and rear rows of blocks along the stopper chamber provides the joint with

7.7
6000

greater flexibility. Compared with other self-anchored joint, Xanchor joint features simpler structure, easier

8.1

1.5

installation, better anti-axial-splippage performance and flexibility.

8.6

120

Working principle
Working principle of Xanchor joint is quite different from that of the traditional self-anchored joint. The

6.8

110

designed to have two annular chambers, i.e. sealed chamber and anchoring chanber. The sealed chamber

25

Application Field

9.9

The same with TF joint, please refer to "1.4.1 Joint description Application Field ";

150

10.8

Installation method

1048

160

11.7

Please refer to "5.2.6 Xanchor self-anchored joint installation

945

1158

175

1000

1048

1308

185

1100

1152

1420

200

1200

1255

1539

215

6000/8150

12.6

23

13.5

22

14.4

21

15.3

20

1 By adjusting the wall thickness class of the pipe and material of connecting bolts, etc., TF joint's PFA can reach 25bar.
Please consult us for detailed technical parameters.

14

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

15

1.5.2 Technical parameters:

1.6 Flange (welding) joint ductile iron pipe

The technical parameters of Xanchor self-anchored joint ductile iron pipe are shown in Figure 9 and Table 8:

1.6.1 Joint description


Sealing Gasket

DE

enom

Bolts & Nuts

Lu
Figure 9 Xanchor self-anchored joint ductile iron pipe

Figure 10 Flange (welding) joint structure

Table 8 Technical Parameters of Xanchor Self-anchored Joint Ductile iron pipe

Sealing principle

K9
DN

DE(mm)

D(mm)

P(mm)

()

1400

1462

1610

330

1500

1565

1710

341

1600

1668

1820

363

1.1

1800

1875

2050

410

2000

2082

2266

430

Lu(mm)

Structure of Flange-joint is shown in Figure 10. Its sealing is realized through the flanges compressing the

enom(mm)

PFA1(bar)

1.2

17.1

19

Joint features and application field

1.1

18

18

18.9

17

Flange joint is rigid joint with sound sealing performance. It is usually used in the following places, such as

1.0

20.7

16

0.8

22.5

15

8000

sealing ring, which is achieved by fastening the bolts.

the connection with pumps, valves, fire hydrant as well as crossing foundation, walls and so on.

1 By adjusting the wall thickness class, Xanchor joints allowable operating pressure can reach PN25.

1.6.2 Technical parameters


Xinxing can provide flange (welded) components ranging from DN80 ~ DN2000. Length of flanged pipe and
the number and position of puddle flange would be customized according to customer requirements. For
detailed product information, please refer to Table 9.
Executive Standards for Flange: ISO 7005-2 or EN 1092-2, for detailed dimensions please refer to:
For centrifugally cast pipes with welded flanges please refer to 6.2 Technical Parameters for Fittings
and Accessories (42);
For welded puddle flange please refer to 6.2 Technical Parameters for Fittings and Accessories (43)

16

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

17

Table 9 Flange (Welded) Pipe Catalogue


Name

Symbol

1.7.1 Product description

Name

Symbol

Double Flanged Pipe

Double-Spigot Pipe with


Puddle Flange

Double Flanged Pipe with


puddle flange

Socket-Spigot Pipe with Puddle


Flange

Flanged Spigot Pipe

Socket Flange Pipe

Flange Spigot Pipe with Puddle


Flange

Socket Flange Pipe with


Puddle Flange

Pipe structure
XTJ jacking pipe, as shown in Figure 11, is to make a tubular reinforced concrete protective jacket on the
external wall of T-type joint pipe. Theres a jacking flange welded on the spigot of the pipe. During the pipe
jacking, the pushing force is evenly passed from the flange with ribbed plate welded at the spigot to the
socket, thus ensuring the pushing operation will not cause deformation of the spigot and will not damage the
outer protective sleeve;
Application Field
XTJ jacking pipes are applied when the pipeline need to cross obstructions such as roads, railways, rivers
and buildings, while trench excavation is not allowed or difficult to prepare on the construction site.
XTJ jacking pipe adopts T-type flexible joint. It features sound sealing performance, faster installation,

Allowable Operating Pressure for Welded Flanged Pipes of K9:


DN80~DN1200

PN10/PN16/PN25

DN1400~DN1600

PN10/PN16

DN1800~DN2000

PN10

more reliable internal and external anti-corrosion coating, and is adaptive to various soil environments and
different transmitted media.

1.7 XTJ Ductile Iron Jacking Pipe

Flange
Concrete Cement
Stiffened Plate

Spigot
Rubber Gasket
Socket

Figure 11 XTJ Ductile Iron Jacking Pipe structure

18

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

19

1.8 External anti-corrosion coating

1.7.2 Technical parameters


Technical parameters of XTJ jacking pipes are shown in Figure 12 and Table 10;
A

1.8.1 Soil aggressivity

DE

1.8.1.1 Soil aggressivity evaluation


Lu

topographical map, based on which initial analysis shall be formed on the corrosivity of the soil. Then,

Table 10 Technical Parameters of XTJ Ductile Iron Jacking Pipes


Dimensions
Wall
thickness
class

250

DE(mm)

D(mm)

A(mm)

274

342

95

300

326

397

100

350

378

448

100

400

429

502

100

450

480

551

110

500

532

616

110

600

635

725

110

700

738

850

150

K9
800

842

956

150

900

945

1064

165

1000

1048

1170

175

1200

1255

1396

205

1400

1462

1630

229

1600

1668

1840

252

1800

1875

2060

290

2000

2082

2280

330

Lu(mm)

Total
weight
(kg)

4000

518

6000

773

4000

639

6000

953

4000

766

6000

1145

4000

907

6000

1353

4000

1045

6000

1554

4000

1268

6000

1890

4000

1626

6000

2423

4000

2281

6000

3385

4000

2661

6000

3992

4000

3171

6000

4706

4000

3684

6000

5376

4000

5027

6000

7436

4000

6841

6000

10151

4000

8310

6000

12380

4000

10110

6000

14895

4000

12046

6000

17740

through on-site examination, further analysis shall be made. Finally, through lab-test of the sample soil,

Allowable jacking force

XINXING PIPES

precise judgement will be made.

KN

Tonf

920

94

1240

127

1270

129

1350

138

1560

159

1910

195

Collect potential corrosive elements for the embedded ductile iron pipes along the pipeline, including

2720

278

corrosive sewage discharged from livestock farms, wineries, paper mills and other factories, or from local

2720

277

3300

337

4140

422

5080

518

7240

739

9020

920

12360

1261

12360

1261

16970

1731

Data collection
Collect the topographical information for the area of pipeline burrial, such as the distribution and
altitudes of level ground, hills, swamp lands, paddy fields, rivers and beaches, soil types of various regions,
transitional areas of two different soils and the terrains with great changes. For example, in the dry area in
high altitude, the soil tends to be less aggressive; while in damp areas in low altitude such as ponds, lakes,
marshes and peat beds, the soil tends to be more aggressive due to rich humic acid and anaerobes. In the
river mouths, lowland, marshes, saline and alkaline lands and other regions along the sea, the aggressivity
of soil is probably high.

residence.

Note: 1. The jacking pipe with grouting hole can be provided according to customer requirements;
2. We could also supply jacking pipe with other wall thickness class. Please contact us for detailed technical parameters.

20

and backfilled soil, and soil polarity caused by local topographical and backfilling. Therefore, technicians
should familiarize themselves with the topographical and geography of the targeted area through

Figure 12 XTJ Ductile Iron Jacking Pipe

Size
DN

Pipelines buried underground will be exposed to various corrosive elements, including the aggressive soil

Xinxing Ductile Iron Pipes Technical Manual

Collect potential disturbing power sources near the pipelines that probably corrode ductile iron pipes,
such as power plants, substations, HV transmission lines, and other forms of DC and AC interfering power
sources.
Gather local meteorological data, including maximum and minimum temperature, average temperature
per year, soil temperature at the burial depth of ductile iron pipes, soil freezing depth, underground water
level, rainfall volume and sunlight intensity, etc.
A report shall be issued with information mentioned above for the reference of designers.

Site surveys
The selection of site surveys shall be based on following principles:
a. At least 2 test points shall be chosen for every soil type;
b. For the same type of soil, one test point shall be chosen every 400~500m;
c. Test points shall be typical for the topographical features of the area along the pipeline;
d. Mark test points on the general pipeline layout plan to make a soil survey test point distribution plan.
Xinxing Ductile Iron Pipes Technical Manual

21

Identify soil texture, color and appearance

1.8.2.1 Zinc+HCPE finishing layer

Investigate the status of underground water and backfill soil

Product description

Soil resistivity test: soil resistivity, as an important index of evaluating soil aggressivity, is a

Zinc coating used as external protection has proved to be one of the most effective anti-corrosion solutions

comprehensive factor of soil water content and salt content, and reflects soil conductivity. In general, the

throughout the world. It can prolong the service life of pipelines. Standard anti-corrosion coating provided

smaller the soil resistivity is, the stronger the soil aggressivity is. AC quadrupole test method is adopted on

by Xinxing is metallic zinc coating applied by electric arc (C-Class pipe 200g/m2, K-Class pipe 130g/m2). A

the site.

HCPE finishing layer of at least 70um thickness will be sprayed outside the zinc coating. Structure of such

ORP test (Eh7): oxidation reduction potential is an index that can reflect comprehensively oxidation

coating solution is shown in Figure 13. The finishing layer is in porous structure, as shown in Figure 14.

reduction degree, which has a lot to do with the activity of bacteria in the soil. To certain extent, the lower

finishing layer

Eh7 is, the greater corrosive action of sulphate reducing bacteria on metals is. Therefore, oxidation

metallic zinc
cast iron pipe

reduction potential can become an index of soil microbiological corrosion under the condition of strong
reducibility.

Laboratory analysis
Laboratory analysis is supplementary to the analysis mentioned above. Chemical analysis conducted in the
laboratory mainly includes the following items:
PH value, total soluble salt, moisture content, soil bulk density, air content, Cl-, SO42-, S2-, microorganisms,
etc.

Figure 13 Zinc+HCPE finishing layer

1.8.2 Selection of external coating

Anti-corrosion mechanism

Zinc coating is the basic external coating solution provided by Xinxing. It features satisfactory anti-corrosion

Active anti-corrosion : Sacrifice zinc anode to protect ductile iron cathode.

performance in most of the soil environments. However, in strong corrosive soil where zinc coating

Stable protective layer: Zinc will corrode gradually to generate insoluble zinc salt in the process of

would not be enough, PE sleeve will be used as additional anti-corrosive coating; or special coatings and

contacting with environmental soil, which will tightly adhere to the pipe walls so as to form a layer of

other strong anti-corrosion methods shall be taken to protect the pipelines. Xinxing can help customers

continuous, tight and insoluble protective film that is impermeable.

design cost-effective external anti-corrosion solutions for pipelines that can fulfill requirements of the soil
environment. Table 11 is a proposed anti-corrosion coating solution based on different corrosion levels of

Pore-sealer

the soil.

zinc

ductile iron pipe wall

Table 11 External Coating Solution for Soils at Different Corrosion Levels


Corrosion level

Pipelines

generality (most of the soil belongs to this level)

Zinc+HCPE finishing layer

corrosive

Zn-Al rare earth alloy + blue epoxy coating


Zinc+HCPE finishing layer+PE sleeve

highly corrosive

special coating (PU coating)

Figure 14 Porous Structure of the coating solution of Zinc+HCPE finishing layer

The porous finishing layer sprayed on zinc coating also plays an important role. It is good for cathodic
protection and self-healing, and also for converted products of zinc to generate stable and tight insoluble
protective film.

22

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

23

Self-healing of damaged zinc coating: Some pipes may be locally damaged probably during

epoxy coating
Zn-Al rare earth alloy

transportation or installation. Zinc will transform into zinc ion rapidly under the action of primary cells. Zinc

cast iron pipe


Cement mortar lining

ion can migrate through pores of finishing layer and cover the damaged portions, generating stable and
insoluble protective layer, as shown in Figure 15.
zinc corrosion products

current

Zn++ ions

Pores of finishing layer


metallic zinc coating
cast iron
Damage

Figure 16 Zn-Al rare earth alloy + blue epoxy coating

Anti-corrosion mechanism
In short, zinc coating plays an important role of anti-corrosion: on one hand, it will generate tight insoluble
protective film which will adhere to pipe walls, thereby reducing electrochemical corrosion to great extent;

Active anti-corrosion: Just like pure zinc, Zn-Al rare earth alloy is also a kind of active anti-corrosion
coating.

on the other hand, the anti-corrosion performance of zinc coating and finishing layer also is reflected on

Stable protective layer: Being similar with zinc coating, a layer of continuous, impermeable and insoluble

their mutual action. There is excellent adhesiveness between zinc and cast iron & zinc and finishing layer,

protective film that is hardly penetrated forms on ductile iron pipe walls. Aluminum in the alloy features

forming a complete protective screen between pipe and the external environment, and preventing anti-

inactivation, and it can reduce the consumption rate of zinc even in the soil with high corrosivity; the addition

corrosion failure.

of a small amount of rare earth element (Re) can purify the coating structure to reduce active points of the

Application field

surface during the coating corrosion; it can also refine the crystal grains and reduce porosity of the coating

This kind of coating is applicable to most of the soil environments with slight aggressivity.

so as to compact the coating structures, thereby reducing the corrosion passages, as shown in Figure 17.

Executive standards:
ISO 2531, ISO 8179, GB /T 13295, GB/T 17456, BS EN 545

blue epoxy

Zn-Al rare earth alloy

ductile iron pipe wall

1.8.2.2 Zn-Al rare earth alloy + blue epoxy coating


Product description
Zn-Al rare earth alloy (i.e. add trace amount of rare earth element in 85Zn15Al) is sprayed on the surface
of ductile iron pipes by electric arc with the coating mass of 400g/m2; epoxy coating (at least 100m in

Figure 17 Porous Structure of the coating solution of Zn-Al rare earth alloy + blue epoxy coating

thickness) is sprayed on the alloy coating so as to form active anti-corrosion coating. Coating structure is
shown in Figure 16.

24

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

25

Zn-Al rare earth alloy coating features self-healing effect just like coating zinc.

1.8.2.3 Polyurethane coating


Product description:

Advantages of Zn-Al rare earth alloy coating

PU coating of ductile iron pipe and fitting is formed by the PU material sprayed and cured on the surface

Due to the addition of rare earth, Zn-Al rare earth alloy coating features the following advantages compared

of pipe/fitting that is bi-component, solvent-free and 100% solid. This kind of coating has excellent anti-

with Zn-Al alloy coating:

corrosion performance, high impact resistance and wearing resistance, which is applicable to the soil with
very strong aggressivity and all other types of the soil.

Reinforcement effect
With strong chemical activity, rare earth element can react with many elements in Zn-Al alloy to generate

Coating structure is shown in Figure 18

intermetallic compounds with strong hardness. Distributed in crystal boundary in a mesh pattern, these
compounds can hinder creep slip, thereby improving the hardness and wear-resistant property of alloy
epoxy coating

coating to prolong the service life significantly.

PU coating
ductile iron pipe wall

Refining effect
During solidification of the coating, rare-earth element can reduce the surface tension of plating solution
to increase the crystal core so as to refine the crystalline grains. Such fine eutectic structures can prevent
the extension of cracks, even the structures and eliminate bare spots on the surface of coating. This is
the important mechanism of rare earth to improve the plasticity and flexibility of the coating, and it is also a
special feature of the rare-earth alloy coating.

Anti-corrosion performance
Re element can refine microstructure of the coating and reduce its porosity. Meanwhile, it can strengthen
Zn-Al alloy coating. Therefore, addition of a small amount of Re element can further improve the anticorrosion performance of Zn-Al alloy coating.

Figure 18 External PU Coating

Coating thickness is as specified in Table 12

Application fields
Zn-Al rare earth alloy coating is an enhanced anti-corrosion solution. It is applicable to the soil with strong
aggressivity (i.e. soil with low resistivity, soil influenced by underground water or mixed soil), where PE
sleeve is not needed, except the following situations:
Acid peat soil;
Soil containing garbage, oxide skin and slag, or soil polluted by waste water and industrial effluent;
Soil below the sea level and with resistivity less than 500cm.
When applied to the soil types listed above, including the one with stray current, other type of external
coatings (such as PU coating) will be recommended.

XINXING PIPES

Adopted material

Average thickness m

Minimum thickness m

pipe body

PU coating

900

700

socket and spigot

epoxy coating

250

200

Requirements for material


PU coating: complying with EN 15189.
Epoxy coating: complying with EN 14901 and certified by WRAS for BS 6920

Xinxing can provide products ranging from DN80 ~ DN2200.

ISO 2531, GB /T 13295 and BS EN 545

Location

Specification range

Executive standards:

26

Table 12 Thickness of External PU Coating

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

27

Additional protection
For the soil with very strong aggressivity, proper additional protection shall be made for the joints during
installation of pipelines, e.g. application of external heating shrink sleeve.

Properties of PU coating are shown in Table 13

Table 13 Properties of External PU Coating


No.

Tested items
Water resistance

Requirement
Less than 15% weight increase after immersion in 50 deionzed water
Less than 2% weight loss after drying

1
Chemical resistance

Less than 10% weight increase after immersion in 10% H2SO4 for 100 days
The weight change 4% after drying.

Impact strength

8 J/ mm of PU on the pipe body coated with polyurethane,the PU coating


shall be free from damage.

Indentation hardness

Under 10Mpa pressure, the depth of indentation < 10 %

Elongation at break

2.5%

Specific coating resistance

10 m

The ratio (resistance after 100 days)/


(resistance after 70 days)

0.8

Non-porosity

When tested with 4.2kV voltage,the PU coating shall be free from porosity.

Hardness

Shore D > 70

Adhesion

Adhesion11 MPa under 23

advantages of PU coating
With strong mechanical strength, rock impact resistance and soil stress resistance, it can hardly be
damaged during handling and installation.
Due to good water resistance and zero anti-permeability coefficient, the coating wont suffer from shellfish
erosion when applied in the marine environment for a long time.
Due to its good performance in chemical resistance and electric corrosion resistance, ductile iron pipes
with PU coating can be applied to complicated soil environment, with prolonged life span.

Application fields
Pipes and fittings with PU coating can be applied to the soil environment with very strong aggressivity and
all other types of soil listed below:
Humid regions such as harbor and marshes;
Hydrous area that is salty and alkaline etc.
Executive standards:
ISO 2531, GB /T 13295, GB/T 24596, BS EN545 and BS EN15189

28

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

29

1.8.2.4 Polyethylene sleeve


Product description:
PE sleeve is the Polyethylene or a mixture of polyethylene and/or ethylene and olefin copolymers sleeve (film)
with thickness of 0.2mm that is wrapped on external walls of the pipe on the construction site. It can prevent
direct contact between cast iron pipes and the soil. Meanwhile, it also prevents underground moisture from
corroding the pipelines. It is used to supplement the basic pipe coating (metalic Znic + HCPE finishing layer)
in certain case of highly corrosive soils or in the presence of stray current.

Requirements for material


The properties of polyethylene sleeve listed in table 14:
Table 14 Properties for PE Sleeve (film)
Tested items

Test results

Test standard

200

ISO 8180

material density/kg/m

910~935

ISO 1183-1

impact resistance/g

900

ISO 7765-1 Method A

tensile strength/MPa

20

ISO 527-3 Type 2

elongation/%

500

ISO 527-3 Type 2

propagation and tear resistance/N

20

ISO 6383-2

thickness/m
3

Specification range
This kind of anti-corrosion coating is applicable to ductile iron pipes of all sizes.
Anti-corrosion mechanism
The anti-corrosion mechanisms for PE sleeve (film) wrapped outside zinc coating are as following:
First of all, PE sleeve can separate the pipelines from corrosive soil and inhibit the generation of
electrochemical cell. At the same time, it can also isolate stray current.
The PE sleeve is a kind of anti-corrosion method whose performance is achieved through the changing
of corrosive environment: it can change the corrosive environment from non-homogeneous soil with strong
aggressivity into one that is homogeneous with weak aggressivity.
Application fields
It is suggested to adopt this kind of protective layer for corrosive soil, for example:
Soil with low resistivity (with indicator of high aggressivity);
Regions with stray current;
Regions with high chlorine or sulphur content or active bacteria indicated by the analysis.
Executive standards:
ISO 2531, ISO 8180 and GB /T 13295

30

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

31

1.9 Internal lining

Usually, various types of water are available to be supplied. Sometimes, it is water with low mineral content

The internal lining of ductile iron pipes must be equipped with excellent hydraulic and anti-corrosion

Xinxing can provide ductile iron pipes with various internal linings, which are applicable for the conduction

performance. Factors such as corrosivity, flow speed and environment temperature of the conveyed fluid

of various types of water; based on the features of delivered water, proper lining materials (such as cement

have to be taken into consideration while choosing the pipe lining. Surface smoothness is also one of the

mortar lining, cement mortar lining with epoxy seal coats, PU lining, or ceramic epoxy lining) shall be chosen

features that to be taken into consideration.

through calculation and analysis.

(e.g. soft water), which may attack the materials just like corrosive or aggressive water.

Adopted for the delivery of potable water, the anti-corrosion lining of ductile iron pipes should be nontoxic.
This is the most basic requirement for the choice of lining.
While adopted for sewerage delivery, the anti-corrosion performance that features microorganism resistance
and liquid erosion resistance becomes very important for the lining. And it is those linings with high abrasion
resistance and strong acid resistance (especially sulfuric acid resistance) that can provide long-term,
reliable protection for the pipes.

1.9.2 Materials in contact with potable water


The materials in contact with potable water shall not influence water quality.
All above materials adopted by Xinxing for ductile iron pipes have passed the WRC-NSF test of BS6920 of
the U.K. and WRAS certification, which proves that such materials can be used for the delivery of portable
water.
Lining materials for ductile iron pipes provided by Xinxing are listed in Table 15.
Table 15 Lining Materials
Material

1.9.1 Evaluation on aggressivity of water for ductile iron pipes


Corrosivity of water
Water can be divided into corrosive water (propersity to attack exposed metal) and aggressive water
(propersity to attack cement mortar lining).

Application Area

Cement mortar lining

linings of ductile iron pipe and fitting

Solvent-free PU

special linings for ductile iron pipe and fitting

Water borne epoxy coating

seal coats

Epoxy coating

Socket and spigot of pipes with special coating

Rubber gasket

Sealing rings for joints of pipes and fittings

1.9.3 Lining Selection


As per the corrosivity of delivered water, anti-corrosion linings of the ductile iron pipes and fittings provided
by Xinxing can be divided into three categories:

Corrosive water
Corrosive water refers to water that corrodes the metal of pipe without lining. Oxygen contained in most of
the water can react chemically with iron, which causes its oxidization, generating nodules and tuberculation
on internal pipe wall. It will reduce the pipe cross section and significantly cause water head loss increasing
over time. This phenomenon often happens in the old pipe without cement mortar lining.

Standard lining: Applicable for most raw water and portable water;
Reinforced anti-corrosion lining: Applicable for water which can attack ordinary cement (soft water,
slightly acidic water or highly abrosive water);
Special lining: Applicable for very special cases or corrosive water (e.g. industrial discharged water)
Xinxing will recommend proper internal linings based on water composition analysis. Table 16 summarizes

Aggressive water
Aggressive water is the water that corrodes calcareous materials (such as cement). Based on chemical

the types of anti-corrosion linings of Xinxing.

analysis, three results will be caused by the changes in mineral content, PH value and temperature of the
water:

Table 16 Types of Lining

Under the given temperature, the water with calcium-carbon balance will neither cause attack nor calciumcarbon deposition.
Scale deposition water tends to generate calcium salt deposition (e.g. calcium carbonate) on the internal
surface of pipe.
Aggressive water can attack the cement mortar containing calcium (e.g. lime, calcium carbonate, or
aluminum silicate, etc.)
According to the relevant international standards, potable water can be neither corrosive nor aggressive.
32

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Lining material
Standard lining

Portland cement mortar lining


High-alumina cement mortar lining

Enhanced lining

Sulphur resistant cement mortar lining


Cement mortar lining + seal coats

Special lining

Xinxing Ductile Iron Pipes Technical Manual

PU, ceramic epoxy lining

33

1.9.4 Cement mortar lining

Features of cement mortar lining


Self-healing

Product description

With the proceeding hydration reaction of cement, the cement mortar lining will shrink gradually. Therefore,

Cement mortar lining of ductile iron pipes is applied through centrifugal application method:

it is inevitable to form radial displacement and small cracks. This is a unique feature of cement mortar, which

When pipes are rotating on the lining machine, certain amount of cement mortar is poured into the pipes.

is allowable by the standard. Thus, no unfavorable influence on the mechanical stability of the lining will be

Through high-speed revolution with acceleration about 30G under the centrifugal force, such cement mortar

brought by such cracks and radial displacement, as well as other cracks caused during manufacturing or

will fully cling to the internal surface of pipe, forming a dense and smooth lining with uniform thickness,

transportation.

which can provide good mechanical properties after curing for certain amount of time. Thickness of cement

When the pipe with cement mortar lining contact water, these cracks and radial displacement will be closed

mortar lining shall comply with specifications in Table 17.

and healed along with expansion of the linings and continuous hydration of cement; therefore, the anticorrosion effect wont be influenced.
Good mechanical property

Table 17 Thickness of Cement Mortar Lining


NominalDN

Lining thickness
Nominal thickness (mm)
Minimum thickness at one point(mm)

Expansion coefficient
The linear thermal expansion coefficient of cement mortar lining is 12 x 10-6/ , which is almost equal to

80300

that of ductile iron (11 x 10-6/ ). Therefore, it can reduce the risk of crack generation due to difference of

350600

thermal expansion coefficients.

7001200

3.5

14002000

Good resistance to longitudinal bending and to ovality

22002600

12

Good resistance to vibration and impact

Good adherence and anti-vacuum performance

With excellent abrasion resistance, cement mortar lining can be used to convey raw water with highly
abrasive particles

Requirements for materials

Excellent hydraulic performance

Different types of cement can be chosen for the


cement mortar lining of ductile iron pipe on the basis

Xinxing adopts centrifugal processing technology for its production of

of delivered water, such as ordinary cement (silicate,

mortar linings, which contributes to the linings smoothness. According to the test of Testing Center of

Portland), sulphur resistant cement (including slag

China Institute of Water Resources and Hydropower Research, the equivalent roughness K of such lining is
1.8

cement), and high-alumina cement.


As an active anti-corrosion coating, cement mortar
lining possesses long-term anti-corrosion effect.
The anti-corrosion mechanism is that cement
mortar lining can release alkaline substance upon
its contact with water. Such substance will gather
on internal surface of ductile iron pipe, resulting in

1.0

19. Therefore, this kind of lining mainly relies upon


its alkaline environment to passivate internal wall
of ductile iron pipe, so as to achieve corrosion

as the tolerance, it is suggested that the value of K selected as 0.10mm for the design purpose.

0
-0.2

Application fields

Fe+3

0.6

Table 19 shows the substances that can be conveyed by various cement mortar linings.

Fe++
a

(cor

Ductile iron pipe with common silicate cement mortar lining is applicable for water-supply project;

Fe2O3

rosio

Ductile iron pipe with sulphur resistant cement mortar lining is applicable for water supply project and

(passivation)

n)

water transmission project with water quality listed in Table 19;

-0.6

Fe3 O

Ductile iron pipes with high-alumina cement mortar lining are applicable for the conduction of sewages

Fe

its passivation, so as to provide electrochemical


protection for base material, as shown in Figure

0.030mm. Taking into consideration of the roughness caused by fittings, valves and other devices, as well

FeO4
b

potential V(S.H.E)

Anti-corrosion mechanism

and industrial wastewater containing certain chemical substances. Nitrile butadiene rubber (NBR) gasket

HFeO2

(immunity)

will be used as accessories for sewage pipelines.

-1.4
-2

ductile iron pipes with cement

0 1

11

13

Figure 19 Potential-pH diagram of Fe/H2O


PH
system (Peurbax diagram)

15

resistance.

34

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

35

Table 18 Conveyable Substances of Different Cement Mortar Linings

1.9.5 Cement mortar lining +epoxy seal coats

Water properties

Silicate cement mortar lining

Sulphur resistant cement


mortar lining

High-alumina cement mortar


lining

PH Value

5.5

Corrosive CO2 (mg/l)

15

unlimited

As shown in Figure 20, cement mortar lining with epoxy seal coats is formed by the curing of water borned

2-

400

3000

unlimited

epoxy spayed on the surface of cement mortar lining. Generally, the thickness of epoxy seal coats around

2+

100

500

unlimited

70um except for special requirements. With excellent anti-corrosion performance, this kind of lining can

30

30

unlimited

ensure the delivered water against pollution.

SO4 (mg/l)
Mg (mg/l)
+

NH4 (mg/l)

1.9.5.1 Product description

Executive standards:
ISO 2531, ISO 7186, ISO4179, GB /T 13295, GB /T 26081, GB /T 17457, BS EN 545 and BS EN598

Lining structure
finish coating
zinc
ductile iron pipe wall
cement mortar lining
epoxy seal coats

Figure 20 Cement mortar lining +epoxy seal coats

36

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

37

Requirements for material

1.9.5.3 Product features

Material of seal coats: pass WRCNSF sanitary test of BS6920 and WRAS certification.
Specification range

Excellent corrosion resistance

Xinxing can provide DN80~DN2200 full range of products

With combined performance of active and passive anti-corrosion, in case epoxy seal coats is damaged or

Certification

some voids exist in the seal coats, cement mortar lining can provide active anti-corrosion protection, thus

In compliance with requirements of ISO16132:2004, it can prevent PH value from increasing in the initial

enabling the coating solution with long-term corrosion resistance performance.

period of water introduction and prolong service life of the lining, thus guarantee water quality. We have

With excellent alkali resistance, it can withstand the alkaline environment of cement mortar linings in long

obtained BV certification on this standard.

run; with excellent acid resistance, it can withstand the erosion of delivered water (e.g. weak acidic water).
Inhibit precipitation of alkaline substances

1.9.5.2 Anti-corrosion mechanism

After 3-months closed cyclic test conducted under conditions of 6 bar pressure and 2m/s flow velocity, the
PH of the test water is far less than 9.5 as required by ISO 16132 (Figure 24 below shows testing procedure
and testing apparatus ).

Anti-corrosion mechanism for cement mortar lining with epoxy seal coats
Structure of cement mortar lining with epoxy seal coats is shown in Figure 23. Ductile iron pipes with cement

The result of short-term sealing performance test is around 8.2, which is far less than the requirement of

mortar lining plus epoxy seal coats combine active anti-corrosion with passive anti-corrosion. On one

PH9.5 specified by ISO 16132.

hand, epoxy seal coats provides a physical barrier for internal wall of ductile iron pipe, which can reduce
water contacting with or isolate water from the internal wall of ductile iron pipe, namely passive corrosion
resistance;on the other hand, this kind of lining can also slow down or stop releasing alkaline substances

from the cement mortar into water, so it can ensure alkaline substancess enrich on internal wall of ductile

iron pipe, and thereby provide chemical protection by means of passivation, namely active corrosion
resistance. In this way, long-term corrosion resistance can be provided for this lining.

10
11
12

1
9
3

13

2
epoxy seal coats
cement lining

14

Stop or slow down releasing alkaline substances from the cement mortar
Ca(OH)2

Ca(OH)2

Ca(OH)2

Ca(OH)2

Ca(OH)2

Ductile iron pipe wall


Figure 22 Sealing Performance Test

Safe and environmental friendly


Figure 21 Structure of cement mortar lining with epoxy seal coats

The epoxy seal coats doesnt contain any organic solvent, thus wont pollute the environment or cause harm
to constructors;
The seal coats is non-toxic after curing, neither polluting water nor producing substances harmful to peoples
health.
It has passed British WRAS sanitary property test of BS6920
The water-bored epoxy coating is compatible with drinking water and has passed WRC-NSF Sanitary test of
BS 6920 and WRAS certification.

38

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

39

Friction reducing affect

Lining structure

Cement mortar lining with epoxy seal coats is smoother than cement mortar lining, which can reduce the

metallic zinc

friction resistance. Xinxing has entrusted an authorized testing organization to test roughness coefficient

cast iron pipe


PU lining

of ductile iron pipes with cement mortar lining epoxy seal coats, and the result shows that its roughness

Epoxy coating

coefficient of K is 0.020mm, which is lower than K of cement mortar lining (K=0.03mm).

1.9.5.4 Application fields


It is applicable for branch pipelines with small diameter,for example, the small- diameter pipeline network in
small towns where the water tends to stay in the pipelines for longer time ;
It is in compliance with green, low-carbon and environment-friendly development direction of ductile iron
pipe industry.
It can be upgraded product to replace the traditional ductile iron pipe with cement mortar lining.
Figure 23 Ductile Iron Pipe with PU Lining

1.9.5.5 Executive standards


Applicable standards for ductile iron pipes and fittings: ISO 2531, GB/T 13295 and BS EN 545
Applicable standard for seal coats of ductile iron pipe with cement lining: ISO16132

Lining thickness
The thickness of PU lining varies with water quality and pipe diameter. The thickness of the linings are
shown in Table 19 and Table 20:
Table 19 Lining Thickness of Pipes and Fittings Applied to Portable Water Delivery as Required in ISO2531
Socket and spigot
(contacting with water)

Pipe body

1.9.6 Polyurethane lining

DN

1.9.6.1 Product description


PU lining of ductile iron pipe and fitting is formed by the PU material sprayed and cured on the surface of

Average thickness
m

80~200

1300

200

1500

Minimum
thickness
m

Average
thickness
m

Minimum
thickness
m

800

300m

250m

Socket and spigot


without contacting with
water
Minimum thickness m
150um

pipe/fitting bodies that is bi-component, solvent-free system. This kind of lining has excellent anti-corrosion
performance and wearing resistance, as well as high impact resistance specific to various transmission

Table 20 Lining Thickness of Pipes and Fittings Applied to Sewage Water Delivery as Required in ISO7186

mediums (such as portable water, wastewater, softened water, municipal sewage, and industrial
wastewater), which is applicable to all water supply projects and municipal sewage drainage projects from
soft water to hard water.

40

XINXING PIPES

DN

Xinxing Ductile Iron Pipes Technical Manual

Socket and spigot


(contacting with water)

Pipe body

Average thickness
m

Minimum
thickness
m

80~200

1300

800

250~700

1500

800

700~1000

1800

1000

1000

2000

1000

Xinxing Ductile Iron Pipes Technical Manual

Socket and spigot


without contacting with
water

Average
thickness
m

Minimum
thickness
m

Minimum thickness m

300m

250m

150um

41

Stability of PU lining

Requirements for material


PU coating: complying with EN 15655, passing WRCNSF test of BS6920 and obtaining WRAS

PU lining of ductile iron pipe produced by Xinxing can provide excellent chemical stability and ageing

Certification.

resistance: the increased weight of coating wont exceed 4% after its immersion in 50 distilled water for

Epoxy coating: complying with EN 14901, passing WRC-NSF test of BS6920 and obtaining WRAS

180 days; the adhesion of PU lining is greater than 8Mpa after it is exposed outdoor for 6 months.

Certificate.

Good flexibility
PU lining also has good flexibility, which can withstand the impact and deformation from transportation,

Specification range

installation or overload with deformation (ovalisation) in compliance with requirement of ISO2531

Xinxing can provide DN100~DN2200 full range of products

With smooth surface, it features small friction and excellent hydraulic performance. Xinxing has

Certification
PU linings of ductile iron pipes produced by Xinxing comply with requirements of GB/T 24596 and BS EN

entrusted authorized testing organization to test roughness coefficient of K of ductile iron pipes with PU

15655 and have passed BV certification.

linings, and the test result is 0.010mm. Considering roughness arising from fittings, valves and other
devices, as well as tolerance, it is suggested that K value shall be 0.050mm for the design purpose.

1.9.6.3 Properties of PU lining


PU lining produced by Xinxing complys with requirements of GB/T 24596 and BS EN 15655, as shown in
Table 21.
Table 21 Technical Requirements for PU Lining
No.

Tested items
water resistance

1
Chemical resistance

1.9.6.2 Product features

As a passive anti-corrosion coating, the effectiveness

Indirect impact strength

Ovality resistance

Less than 15% weight increase after immersion in 50


deionized water for 100 days.
Less than 2% weight loss after drying
Less than 10% weight increase after immersion in 50 10%
sulfuric acid for 100 days.
The weight change4% after drying
Impacted with energy E with the minimum value of 50J/mm, the PU lining shall be free
from damage.
DN
100~250
300~600
700~2000

Ovality of pipe
2% ~ 4%
3% ~6%
4%~ 8%
The coating shall be free from damage.

of PU lining depends on its sustainability, adhesion and


stability over time.

Elongation at break

2.5%

Continuity and sealing performances of PU linings:

Resistance of coating in
0.1M NaCl solution

108m2

with PU lining produced by Xinxing under the testing

ratio of 100d resistance/70d


resistance

0.8

voltage of 6kV, which is higher than 4kV as specified in

Resistance to light ageing

Adhesion8 MPa after the lining is exposed outdoor for 6 months.

Non-porosity

When average thickness of the lining1500m, No breakdown with Holiday detector


at 3.0kv;
When average thickness of the lining > 1500m,

Holiday test must be conducted for each ductile iron pipe

BS EN 15655, so as to guarantee the sustainability of PU


linings.

PU lining can provide excellent adhesion, where

No breakdown with Holiday detector at 4.0kv.

Xinxing requires that it shall be no less than 11Mpa under


23 ;

42

Technical requirements

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Hardness

Shore D > 70

10

Adhesion

At 20 , adhesion 11 MPa

11

Abrasion resistance

The wearing depth of the lining 0.2mm after 100000 movements (50000 cycles)

Xinxing Ductile Iron Pipes Technical Manual

43

1.9.6.4 Application fields

Lining thickness
In order to ensure overall corrosion resistance of the pipe lining, the thickness of ceramic epoxy lining and

Ductile iron pipes with PU linings can be used to deliver water as follows:

coating of socket and spigot shall comply with requirements in the table 23:

all types of portable water, sewage water with PH 1~13 and industrial water shown in Table 22:

Table 23 Thickness of Ceramic Epoxy Lining

Table 22 Characteristics of Water Conveyed

Socket and spigot (epoxy coating)

Transmitted mediums

PH of transmitted mediums

Portable water

1~13

Sewage water

1~13

Industrial water

13

Pipe body (ceramic epoxy)

Area contacting with water

Area without contacting


with water

Minimum thickness m

Minimum thickness m

Minimum thickness m

1000

250 m

150um

Routine test

Soft water or pure water, such as water desalted from seawater.

Adhesion test: Ceramic epoxy lining possesses excellent adhesion. Xinxings requirement on adhesion

Maximum temperature of the substances transmitted by such lining is 45 .

for such lining10Mpa under 23


Thickness test: Thickness test shall be conducted for each product.

1.9.6.5 Executive standards

Non-porosity: Each ductile iron pipe with ceramic epoxy lining shall be subject to holiday test under

Applicable standards for ductile iron pipe and fitting: ISO 2531, ISO 7186, GB /T 13295, GB /T 26081, BS
EN 545 and BS EN598
Applicable standards for PU lining of ductile iron pipe: GB/T 24596 and BS EN 15655

3kv, so as to ensure the continuity of epoxy ceramic lining.


Requirements for material
Ceramic epoxy is bi-component and solvent-free paint with ceramic fillers added at least 20% in volume;
such fillers consist of quartz powder and aluminum oxide powder with different size proportion so as to
provide a hard and wearable ceramic lining.

1.9.7 Ceramic epoxy lining

Specification range
Xinxing can provide DN100~DN2200 full range of products

1.9.7.1 Product description


The ceramic epoxy lining of ductile iron pipe and fitting
is formed by the ceramic epoxy paint sprayed on the
surface of pipe/fitting bodies that is bi-component,

metallic zinc
cast iron pipe
ceramic epoxy lining
Epoxy coating

1.9.7.2 Product features


With excellent anti-corrosion performance and abrasion resistance, the coating is featured as compact
and tough;

solvent-free system. The thickness of the lining1000um.

The coating surface is smooth as the mirror with small friction and excellent hydraulic performance. It

Ceramic epoxy coating contains ceramic fillers at least

is suggested to take K as 0.050mm for design purpose.

20% in volume, so this kind of the lining has excellent

The coating is solvent-free, without volatile solvent released during usage, so it complies with safety

anti-corrosion performance and abrasion resistance

and environmental protection requirements.

performance, as well as good anti-corrosion and abrasion


resistance performance to various transmission mediums

1.9.7.3 Properties of linings

(such as municipal sewage and industrial wastewater),


which is applicable to municipal sewage discharge Figure 24 Ductile Iron Pipes with ceramic epoxy lining

Table 25 shows the properties of ductile iron pipe with ceramic epoxy lining produced by Xinxing:

projects.
Lining structure

44

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

45

1.10 Coating repairment

Table 24 Properties Ceramic Epoxy Lining


Items

Performance requirement

Testing method

abrasion depth after 100,000 movements


(or 50,000 cycles)

0.075mm

ISO 7186

Impact resistance

5J no damage of the coating can be found during


the visual inspection

ISO 6272-1

Water vapor permeability 30d

0.00

ASTM E96 method A

Salt spray resistance (scratch), 5% 30d

No blistering on the coating, no decrease for


adhesion, and no spreading of corrosion at
scratches.

ISO 7253
ISO 4628

Chemical
resistance

Distilled water (70 )

No changes of the coating for 4 weeks

25% NaOH(60 )

No changes of the coating for 4 weeks

20% H2SO4

No changes of the coating for 4 weeks

tap water (scratch)(50 )

no spreading of corrosion at scratches for 4 weeks

1.10.1 Repairment of Zinc coating + HCPE finishing layer/Zn-Al rare earth alloy + epoxy
coating
Repairment ofsuch coatings consists of two steps:
Step 1: Repairment zinc coating/Zn-Al rare earth alloy coating
Step 2: Repair blue epoxy coating or HCPE finishing layer

1.10.1.1 Repairment of Zinc Coating/Zn-Al Rare Earth Alloy coating


ISO 4628 evaluation

Adhesion

10Mpa

ISO 4624

Coating thickness

1000um

ISO 2808

Non-porosity

3KV

NACE PR0188

Equipment required
brush
paint brushes
roller
gas torch
Repairing paint:
Zinc-rich primer:10kg

1.9.7.4 Application fields


It is applicable to municipal sewage and industrial wastewater discharge projects containing higher amount
of solid particles.

Procedure
Brush to remove dirt

1.9.7.5 Executive standards


Applicable standards for ductile iron pipes and fittings: ISO 7186, GB/T 26081 and EN 598
The temperature of surface to be repaired shall be 5 above the dew point
at least. In case that the surface is wet or the ambient temperature is very low,
the surface can be heated by gas torch so as to keep it dry and at least 5
above the dew point.
According to the requirements in Zinc-Rich Primer Product Specification
provided by the supplier, the paint shall be mixed in proportion evenly and
brushed on the surface to be repaired. The coating thickness shall reach at
least 200g/m2 (When the coating is Zn-Al rare earth alloy, the thickness shall be
equivalent to the weight of Zn-Al rare earth alloy coat). The coating appearance
shall be smooth without bubble, void or other defect.

46

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

47

1.10.1.2 Repairment of blue epoxy coating /HCPE finishing layer

1.10.2 Repairment of PU coating

Equipment required
brush
paint brushes
roller
gas torch
Repairing materials:
Blue epoxy paint - used to repair Zn-Al rare earth alloy + epoxy coating
HCPE anticorrosion paint - used to repair zinc coating + HCPE finishing layer

Equipment required
wire brush
paint brushes
spatula
chisel
rotary wire brush
gas torch
Repairing materials
SPUA-R300 solvent-free PU paint

Procedures
Remove the damaged coating and its surrounding coat
with poor adherence by knife or other tools and remain
the coat with sound adhesion and no defect. Clean the
surface of ductile iron with a motor wire brush or other
tool until its surface reaches St3. Brush away debris and
dust to keep the repair-to-be surface clean.

Procedures
Brush to remove dirt

The temperature of surface to be repaired shall be 5 above the dew point


at least. In case that the surface is wet or the ambient temperature is very low,
the surface can be heated by gas torch so as to keep it dry and at least 5
above the dew point.
According to the requirements in product specification provided by the paint
supplier, the paint shall be mixed in proportion evenly, and brushed on the
surface to be repaired. The thickness of black finishing layer is at least 70
um, and the thickness of blue epoxy coating is at least 100um. The coating
appearance shall be smooth without bubble, void or other defect.

The temperature of surface to be repaired shall be 5


above the dew point at least. In case that the surface is
wet or the ambient temperature is very low, the surface
can be heated by gas torch so as to keep it dry and at
least 5 above the dew point.

According to the requirements in Product Specification


provided by the material supplier, the repairing material
shall be mixed evenly in proportion and brushed on the
surface to be repaired. The coating thickness shall be 700
um at least, and the coating appearance shall be smooth
without bubble, void or other defect.

48

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

49

1.10.3 Repairment of cement mortar lining

1.10.4 Repairment of cement lining with epoxy seal coats


The repairing of this coating consists of two steps:

Equipment required
wire brush
paint brushes
Trowel
spatula
chiselhammer
palette knife
repair products

Step 1: Repairing cement mortar lining (see 1.11.3)


Step 2: Repairing epoxy seal coats
Repairment of epoxy seal coats
Equipment required
brush
paint brushes
roller
Repair materials:
WB-108 epoxy paint (gray)

Procedures
Turn the area to be repaired to face upwards.
Remove the damaged area and surrounding hollow lining with
a hammer or driver
The edges shall be vertical to the ductile iron pipe wall and
ductile iron surface shall be exposed

A
Remove any loose debris with a wire brush
Clean the surface to be repaired thoroughly, including part of
the rusted substrate.
Wet the area to be repaired
Wet cement mortar lining around the area to be repaired a few
minutes before the repairing work

B
20kg

4kg

Preparation of repairing material


Ratio of components
Material
Cement
Fine sand
Water

Proportion
Weight ratio A:B = 5:1
Stir component A before mixing. Weigh five portions of component A and one
portion of component B prior to use as required. Place them into a container.
Stir them at least 3 - 4 minutes with a blender or stirrer driven by low-speed
electric drill, until they are mixed evenly.
The ready mixture shall be used up under 25 within 2h. Otherwise, it shall
be discarded.

Procedure
Brush to remove dirt

Weight Ratio
100
200
35~40

Firstly mix two kinds of powder materials, and then add certain
amount of water, mixing to obtain the continuous slurry.
If necessary, add small amount of water according to the
viscosity.

Brush the ready paint on the surface to be repaired with thickness of gray
epoxy seal coats of 70 um. The coating appearance shall be smooth without
bubble, void or other defect.

Fill the defective parts with new mortar, smear the mortar
on it to a uniform thickness with a trowel and make it dense.
Operate evenly to obtain flat and smooth surface. If required,
regularly water the trowel to facilitate troweling

The coating shall be naturally cured above 5 ; In case that temperature is


too low, it is necessary to appropriately heat the coating for cure.

The repaired part shall be fully cured and not exposed in


sunshine. It shall be covered with plastic cloth to keep the
humidity

50

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

51

1.10.5 Repairment of ceramic epoxy(PU)lining


Tools required
wire brush
paint brush
spatula
chisel
motor wire brush
gas torch
Repairing materials
Solvent-free ceramic epoxy repair material for ceramic epoxy lining;
SPUA-R400 hand brush polyurethane for PU lining

Procedure
Remove the damaged coating and its surrounding coat with poor adherence
with knife or other tools and remain the coat with sound adhesion and no
defect.
Clean the substrate of ductile iron base with a motor wire brush or other tool
until its surface reaches St3.
Brush away debris and dust to keep the repair-to-be surface clean.

The temperature of the surface to be repaired shall be 5 above the dew point
at least. In case that the surface is wet or the ambient temperature is very low,
the surface can be heated by gas torch so as to keep it dry and at least 5
above the dew point.

According to the requirements in Product Specification provided by the material


supplier, the repairmaterial shall be mixed evenly in proportion and brushed on
the surface to be repaired. The coating thickness shall be at least 1000um, and
the coating appearance shall be smooth without bubble, void or other defect.

52

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

53

Chapter II
Manufacturing
Process and
Quality Control
System

54

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

55

Chapter II
Manufacturing
Process and
Quality Control
System

2.1 Manufacturing Process

58

2.1.1 Preparation of molten iron


2.1.2 Pipe Casting
2.1.3 Finishing / coatings
2.2 Quality Control System

62

2.2.1 Production procedure of ductile iron pipe


2.2.2 Quality control and inspection frequency
2.2.3 Joint performance test

56

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

57

2.1 Manufacturing Process

2.1.2 Pipe Casting


2.1.2.1 Preparation of Sand Cores
The pipes with different joints are produced with pipe molds
with different joint-sand-cores. The core sand mixed with resin

Molten iron from


blast furnace

Composition adjustment
in the electric furnace

Spheroidizing

is added into the sand core mold, tamped and solidified for the

Centrifugal casting

centrifugal casting.

Sand cores

2.1.2.2 Centrifugal casting


The high-quality ductile iron pipe is produced by the centrifugal casting process: After spheroidization, the
Pressure Test

Polishing

Zinc coating

Annealing

Weighing

qualified high-temperature molten iron flows through a launder into the metal mold rotating at high speed,
and then is distributed on the internal surface of metal mold under the centrifugal force, finally it is solidified
into a pipe. The impurities and gas in molten iron is sufficiently excluded due to the centrifugal force. The
gradual inward solidification makes the pipe wall extremely dense, so as to save materials to the most and

Cement mortar lining

improve the mechanical properties of pipe.


Curing

Spray of external
finishing layer

Packing storage

Figure 1 Manufacturing Process for Ductile Iron Pipe

2.1.1 Preparation of molten iron


2.1.1.1 Molten iron smelting
The Fe in the iron ore is reduced in the blast furnace, which will also keep suitable composition of Si, Mn, S,
P, and other trace elements in molten iron.
With the storage function, the metal mixer can be utilized between the blast furnace and electric furnace for
the buffering and thermal insulation, so as to obtain the suitable composition of molten iron.
The composition and temperature of molten iron can be adjusted in the electric furnace to achieve suitable
values for spheroidisation.

2.1.2.3 Annealing
Annealing treatment is a necessary and important procedure during production of ductile iron pipe.

2.1.1.2 Spheroidization and Inoculation

Generally, the elongation of ductile iron pipe by centrifugal casting is 2~5%, inferior to the requirement

After the molten irons spheroidization through the addition of

specified by ISO 2531. In order to enhance elongation, the cast pipe shall be annealed, that is, the pipe

magnesium, the precipitated graphite will change its form from

is heated to certain temperature in the annealing furnace, and then cooled to below certain temperature

flake to spheroid during solidification, thus avoiding incision of flake


graphite to the continuity of iron matrix, so that enabling the ductile
iron with excellent ductility, flexibility and impact resistance.

along with the proper annealing curve, and continuously cooled in ambient temperature. After the annealing
Spheroidization of molten iron

treatment, the mechanical properties of ductile iron pipe can reach the indexes in the Table 1 and comply
with ISO 2531:

Inoculation is an important procedure during production of ductile


iron, through which graphite in the ductile iron can become more
rounded and refined, so that the spheroidizing level can be
elevated, and the pipe wall can become denser in structure; in
addition, the product prasticity and toughness can be improved too.
The metal-stream inoculation is performed along with the centrifugal
casting simultaneously.
58

XINXING PIPES

Component analysis
Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

59

Table 1 Mechanical Properties of Ductile Iron Pipes


Type of casting

Minimum tensile strength


Rm/MPa

2.1.3.2 Hydrostatic Test


Each ductile iron pipe and fitting manufactured by Xinxing shall be subject to hydrostatic test in accordance

Minimum elongation A /%

DN80~2000

DN80~1000

DN1100~2000

Centrifugal ductile iron pipe

420

10

Fittings, non-centrifugal ductile


iron pipe

420

Note: 1. The yield strength (RP 0.2) can be measured by agreement between the supplier and purchaser. Where:
RP 0.2 270MPa, when A 12% for DN80 ~ 1000; or RP 0.2 270MPa, whenA 10% for DN 1000 and above.
RP 0.2 300MPa under other conditions.
2. For centrifugal ductile iron pipes between DN 80 ~ 1000,when the wall thickness class is above K12, minimum elongation is 7%.

with ISO 2531, qualified result of which is the prerequisite for the products entering into the next procedure .

2.1.3.3 Cement mortar and other lining


Taking into consideration the sanitation requirements of urban water supply to prevent water pollution
against rust, it is necessary to conduct anti-corrosion protection for pipe from inside through application
of internal lining. Without special requirement, all ductile iron pipes produced by Xinxing shall be
internally lined with cement mortar complying with the portable water requirements.
According to the requirements of ISO 4179, Xinxing adopts the centrifugal lining process, through which
the cement mortar lining surface features smoothness, uniformity and flatness, as well as high bonding
strength with pipe wall, and is not easy to fall off.
Pipes with cement mortar lining centrifugally applied shall be placed in the environment with high
temperature and humidity, so as to accelerate the maturation of cement mortar lining.

2.1.3.4 Finish coating, package and storage


Annealing

Mechanical properties test

After the spraying of finishing coating and marking, the cured pipe (DN 300) will be packed and put in
storage, and then shipped to the designated location as scheduled.

2.1.3 Finishing / coatings


2.1.3.1 Zinc spray on external wall
After the annealing treatment, the external surface of the pipe is sprayed with zinc coating complying with
ISO 2531 by means of the electric arc spraying process: utilize low voltage and high current power to melt
zinc wire; atomize the molten zinc with high-speed compressed air stream, and then spray it on the external
wall of pipe in the form of micro droplet.

Zinc coating

60

XINXING PIPES

Finished Products Warehouse


Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

61

2.2 Quality Control System


2.2.1 Production procedure of ductile iron pipe
Inoculant

Qualified

SQA
Composition

composition
Molten iron temperature&
composition adjustment

Disqualified

pipe mold
maitenance

Ferrosilicon,
magnesium

Molten iron

SQA
Composition
Particle size

Composition
Temperature
Spheroidisation

Sand, resin

Core preparation
Composition
Temperature

Dimensions
Appearance
Centrifugal casting

Disqualified

Appearance
Pipe weight
Pipe heat treatment

Disqualified

Appearance
Dimensions

SQA
Composition
Particle size
Dimensions
Appearance
Strength

Disqualified
Reject

Hardness performance

Reject

Zinc spray

structure

Sand, cement

Thickness

Finishing
Disqualified

Appearance
Dimensions

Preparation of
cement mortar

inspection

Weight

Cement mortar lining

SQA
Particle size

Leak tightness
Lining thickness

Legend
Start, end
Operating

Cement mortear lining curing

Appearance

Product inspection
Process control

Cement mortear lining polish

Supplier quality assurance


Monitoring, tracking
Self-monitoring on post
Inspection

Appearance
Spray finishing layer

Thickness
Marks spray
Disqualified

Packaging
Appearance

SQA
Inspection

Package

Completion,
storage

62

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

63

2.2.2 Quality control and inspection frequency

2.2.3 Joint performance test


Each type of joint newly designed by Xinxing shall be subject to performance test strictly in accordance with
ISO10804-1 and EN 545. It shall pass third party certification before put into market.

Table 2 Quality Control and Inspection Frequency


No.

QC Item

Testing Frequency

Inspection Equipment

Dealing with Nonconforming


Products

Composition of molten iron


from the blast furnace

Each furnace

Spectrometer

Return

Composition of molten iron


from FM furnace

Each furnace

Spectrometer

Readjust

Temperature of molten iron


from FM furnace

Each furnace

Thermometer

Readjust

Composition of nodulized
molten iron

Each pack

Spectrometer

Return

Core appearance

Full testing

Visual inspection

Repair or destroy

Core dimensions

5 pcs/shift/specification

Caliper

Destroy

Pipe mold dimensions

Each piece

Micrometer, dial indicator

Rework

Casting temperature

Sampling test every 3~10


pieces

Thermometer

Adjustment or return

Appearance

Each piece

Visual inspection

Adjustment

10

Pipe weight

Each piece

Platform scale

Adjustment

11

Furnace temperature

Test along production, record


every half-hour

Thermal instrumentation

Adjustment

12

Chain speed

Test along production, record


every half-hour

Inverter

Adjustment

13

Appearance

Each piece

Visual inspection

Reject

14

Mechanical property

1 piece/batch

Universal Testing Machine

Reject

15

Zinc coating weight

1 time/day

Electronic balance

Rework

16

Pipe weight

Full testing

Electronic scale

Reject

17

Dimensions

Full testing

Standard round and card


board

Reject

18

Pressure Test

Full testing

Pressure test machine

Reject

19

Ratio of cement mortar

Each bucket

Electronic scales, water meter

Adjustment

20

Lining appearance

Each piece

Visual inspection

Reject or rework

21

Lining thickness

1 time/hour

Steel needle, steel ruler

Reject or rework

22

Curing time

Each furnace

Watch

Adjust

23

Curing temperature

Each furnace

Thermometer

24

Appearance

Full testing

Visual inspection

Reject or rework

25

Film thickness

3 pcs/shift/specification

Coating thickness tester

Rework

26

Lining thickness

3 pcs/shift/specification

Coating thickness tester

Reject or rework

Purpose and inclusion of performance test


It is to verify the mechanical strength and leak tightness of the joint under the most unfavorable applicable
conditions of casting tolerance and joint deflection. The specific contents and requirements are listed in
Table 3 for performance test of the flexible joint.
Table 3 Inclusion and Requirement of Performance Test for Pipe Joint
Tested item

Test requirements

Test conditions

1. Positive internal
hydrostatic pressure

Test pressure:(1.5PFA +5) bar


Test duration: 2h
No visible leakage
Test pressure:-0.9 Bara

2. Negative internal
pressure

Test duration: 2h
Maximum pressure variation during the
test: 0.09 Bar

3. Positive external
hydrostatic pressure

Test pressure: 2 bar


Test duration: 2h
No visible leakage

4. Cyclic internal hydrolic


pressure

24,000 cycles
Test pressure: Between PMA and
(PMA-5) bars
No visible leakage

Test method

Joint of maximum annulus,aligned and


withdrawn, with maximum shear load
Joint of maximum annulus,
deflected
Joint of maximum annulus, aligned and
withdrawn, with maximum shear load
Joint of maximum annulus, deflected

Refer to ISO 2531/


EN 545, etc.

Joint of maximum annulus,


aligned, with maximum shear load
Joint of maximum annulus,
aligned and withdrawn, with maximum
shear load

a. 0.9 bar under the atmospheric pressure

Performance test apparatus

W
F

Figure 2 apparatus for positive/negative internal hydrostatic pressure and cyclic internal hydraulic pressure
W/2
W/2

W/2

Figure 3 apparatus for positive external hydrostatic pressure

64

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

65

Chapter III.
Requirements
for Storage and
Transportation
of Ductile Iron
Pipe

66

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

67

Chapter III.
Requirements
for Storage and
Transportation
of Ductile Iron
Pipe

68

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

3.1 Lifting of Ductile Iron Pipe

70

3.1.1 Precautions
3.1.2 Lifting tools
3.1.3 Lifting
3.2 Transportation

71

3.3 Storage

71

3.3.1 Requirements for Stacking Site


3.3.2 Stacking patterns

Xinxing Ductile Iron Pipes Technical Manual

69

3.1 Lifting of Ductile Iron Pipe

3.2 Transportation

3.1.1 Precautions

(1) If truck or train is adopted for transportation. The carriage must be cleaned without foreign matters. At

Ductile iron pipe shall be lifted by straps or special tools and handled with care. The pipes shall be matted

the same time, the loading scheme shall be prepared according to the acceptable capacity of vehicle;

steadily and firmly without collision with each other during shift-loading and transportation. The operation

(2) If truck or train is adopted for transportation, planks formed by two or more pieces of wood shall be

shall strictly follow the requirements of protection and fastening, so as to avoid damage to the pipe and

placed on the carriage floor so as to avoid the direct contact between the socket end and carriage floor; If

protective coating.

a flat bed trailer is used for transportation, the casting pipes shall be placed on planks and then fixed by
wedges; the length of pipe extending out of the vehicle shall not exceed 1/4 of the pipe length; if iron pipes

3.1.2 Lifting tools

are loaded in more than one layer, the pipe spigot and socket end of each layer shall be staggered and

The crane or forklift is available for lifting, where

finally fixed with steel wire rope firmly; the soft protective materials shall be used to separate pipe and pipe,

special hooks shall be applied, as shown in Figure

pipe and rigid vehicle body, as well as pipe and fastening steel ropes;

1. The special hooks include steel hook covered by

(3) While unloading from the vehicle, it is necessary to avoid directly pulling or dropping the ductile iron pipe

rubber, nylon strap or steel wire rope covered by

,wrapped or not, over the ground, even over the sand ground,for dropping them.

rubber , so as not to damage the internal cement


mortar lining and external protective coating, thus
Figure 1 special hooks

protecting coating of both sides.

3.3 Storage
3.3.1 Requirements for Stacking Site

3.1.3 Lifting

3.3.1.1 The selected site for ductile iron pipe storage shall be flat and solid, and the following places shall
3.1.3.1 For ductile iron pipes packed in bundles, strap and special lifting tools shall be used to lift them from

be unacceptable:

the bottom of whole bundle. It is prohibited to directly hook pipes or package strap so as to avoid packing

- Unstable or sloped areas;

distortion, breakage of package straps or bundle-off during lifting. Generally, one hook is to lift one bundle.

- Swampy areas;

If it is necessary to lift several bundles by a hook, the special lifting gear shall be used to prevent packing

- Seriously polluted land;

deformation, so as to avoid the package damage, such as steel belt breakage and bundle deformation;

3.3.1.2 Two tracks of wooden planks shall be placed under the pipes to avoid their direct contact with the

3.1.3.2 For ductile iron pipes packed in bulk, special hook or lifting strap can be used to lift one or several

ground, and the selected wooden planks shall be solid.

ductile iron pipes each time, as shown in Figure 2;

3.3.1.3 For the long-term storage, the pipes shall be covered with canvas or woven cloth, so as to protect

3.1.3.3 When forklift is applied, all its areas contacting with the pipes must be protected during lifting;

the pipes against dust or dirt.

3.3.2 Stacking patterns


3.3.2.1 Ductile iron pipes can be stacked in two patterns, i.e. the square and pyramidal form.
3.3.2.2 The square stack pattern is shown as Figure 3. The planks are placed under the bottom layer and
fixed with wooden wedges. In each layer of ductile iron pipe, the spigots and socket ends shall be arranged
alternately. For ductile iron pipes in adjacent layers, spigots and socket ends shall also be alternately, and
the upper layer shall be perpendicular to the lower layer. The width of each layer shall not exceed 5.5m.
3.3.2.3 "Pyramid" stack pattern is shown as Figure 4. The bottom layer of ductile iron pipes is placed on two
rows of parallel planks with distance of about 1,000mm to each pipe ends; the planks are fixed with wedges.

Figure 2 Lifting Operation

70

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

71

Table 1 The Stacking Mode for K9 Ductile Iron Pipe

The socket and spigots ends of pipes of each layer are arranged alternately.
Taking into account the bearing capacity of the underlying pipes, the stacking height for K9 ductile iron pipe
is recommended as shown in Table 1, and the preferred height for C-Class ductile iron pipes is shown in

Recommended stacking layers


Size

Size

Table 2.

Figure 3 Square stacking

Figure 4 Pyramid stacking

Recommended stacking layers

Pyramid

Square

Pyramid

Square

DN80

16

16

DN700

DN100

16

16

DN800

DN125

16

16

DN900

DN150

12

12

DN1000

DN200

12

12

DN1100

DN250

12

DN1200

DN300

12

DN1400

DN350

12

DN1500

DN400

12

DN1600

DN450

12

DN500

DN1800 and above

DN600

Table 2 Stacking Mode for C-Class Ductile Iron Pipes With Preferred Pressure Class
Recommended stacking layers
DN

Qty. of package for stacking


(layers per pack)

(m)

80

7(4)

100

6(4)

150

5(3)

200

5(2)

3.3

250

4(3)

3.6

300

4(2)

3.1

Pyramid

72

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Recommended stacking height

350

14

4.0

400

12

4.0

450

10

4.0

500

3.5

600

3.7

700

3.5

800

3.4

900

3.9

1000

3.5

Xinxing Ductile Iron Pipes Technical Manual

73

Chapter IV.
Engineering
Design of
Water Supply
& Drainage
Pipeline

74

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

75

4.1 Determine the regional water demand and satisfy the requirements
for water pressure 78
4.1.1 Determination of water consumption
4 .1.2 Water delivery pressure
4.2 Selection of pipe diameters 79

Chapter IV.
Engineering
Design of
Water Supply
& Drainage
Pipeline

4.2.1 Formula to calculate pipe diameter


4.2.2 Determination of the economic velocity
4.3 Selection of piping system 83
4.3.1 Types of pipeline system
4.3.2 Principle of pipeline design
4.3.3 General requirements for pipeline layout
4.4 The calculation of head losses

85

4.4.1 Formula to calculate linear head losses


4.4.2 Linenr head losses
4.5 Prevention and calculation of water hammer 95
4.5.1 Overview
4.5.2 Causes of water hammer
4.5.3 Hazards of water hammer
4.5.4 Prevention for water hammer
4.5.5 Simplified calculation of water hammer
4.6 Depth of cover for pipeline 99
4.7 Anchoring methods and design 106
4 .7.1 Thrust force F
4.7.2 Form of concrete anchor blocks
4.7.3 Anchor blocks design
4.7.4 Anchoring length of self-anchoring system

76

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

77

water-consuming sectors in a safe, economical


and adequate manner. The main design contents
include:
A. Determine the regional water demand, and satisfy
the requirements for water quality and pressure;

consumption Qh can be calculated as of the maximum daily water consumption Qd:

Qh=

1000xKh xQd
24x3600

C. Select the best type of piping systems;


D. Select the appropriate construction methods
according to the actual conditions in construction site;

4.1.1 Determination of water


consumption
During design of water supply system, the water
supply scale shall be firstly determined. Daily

Kh xQd
86.4

l/s

The total water consumption of community is subject to the local water resources, economic development,
living habits, industrial and agricultural production scale and so on, and the check computation shall be
conducted by reference to the design standards for local living water consumption and relevant industries.

4 .1.2 Water delivery pressure


When the pipeline engineering is designed for water supply from Water Source A to Community B, it is
necessary to consider the requirement for water pressure at the most unfavorable position in Community B.

B. Determine the size of water-supply pipes while


taking into account the economy and reliability;

ELA-Hc-HtP
EL ALowest hydraulic elevation at
Water Source A

hydr

aulic

HCElevation of the most unfavorable


water-supply point C

grad

ient

PMinimum service head at the most


unfavorable water supply point C in the

Jt

project, which is to provide qualified water to

When taking into account the hourly variety coefficient Kh of water consumption, the maximum hourly water

design elements of the water supply & drainage

(m3/d)

water-consuming point B
Ht total head loss of pipeline

Hc

The water volume and pressure are two major

Qd=(1.15~1.25)(Q1+Q2+Q3+Q4+ Q5)

ELA

4.1 Determine the regional


water demand and satisfy
the requirements for water
pressure

water consumption Qd designed for community is

total headloss of the pipeline

composed of the residential water consumption


Q1, living water consumption of enterprise staff Q2,
and water consumption of local public buildings,

4.2 Selection of pipe diameters

sprinkling roads and municipal greening and fire,


Q 3 , the agricultural water consumption Q 4 and
industrial water consumption Q5.
In addition to a variety of water consumption
above, the unforeseen water consumption and
pipeline leaks which is equivalent to 15%~25% of
the maximum daily water consumption need to be
added.
Therefore, the highest daily total water consumption
of the community in the design life can be calculated

4.2.1 Formula to calculate pipe diameter


After the water volume Q is determined, according to the flow calculation formula:
2

Q=

D v

4
Formula to calculate pipe diameter can be obtained as below:
D=

4xQ
xv

Where: v - flow velocity (m/s)

as below:
78

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

79

It is indicated from the above formula that: When water volume Q is determined, the smaller flow velocity v

characteristics throughout one year, which can serve as the basic data to calculate the annual electricity

will result in the larger pipe diameter D, and correspondingly increase the construction cost of pipe network;

charges for operation.

however, it can reduce pipe head losses and the corresponding cost for pipe network management; and
vice versa.

4.2.2.2 Total cost of pipes with different diameters

Therefore, the following issues shall also be considered during selection of pipe:

Through calculating total cost of pipes with different diameters, the diameter of pipe with the lowest total

The first is construction cost of pipeline which covers the material cost of piping components, the equipment

cost is the most reasonable, and it is the economic diameter.

cost, such as pressurized water pump unit, expenses for installation and construction, etc.

Total cost calculating formula:

The second is pipeline operation & management costs, including power cost for pipelines opertion,

W=Cp+CmNPV+CeNPV

maintenance cost and interest on investments. In most projects, usually several comparative solutions are

designed, from which a most economical and practical solution will be selected.

Cp Pipeline investment (RMB 10,000)

Therefore, the optimization method is commonly used to obtain the best solution of velocity v or pipe

CmNPV NPV sum of pipeline maintenance cost of each year within calculation period

Where W Total cost (RMB 10,000)

diameter D during the pipe network design, namely: in a certain period t (payback period of pipeline

($ 10,000)

project), the velocity with the minimum sum of the construction cost and management fees of pipe network

will be taken as the economical velocity to determine the diameter D.

1)Pipeline investment Cp

In order to prevent the pipe network accidents against water hammer phenomenon, it is recommended that

Pipeline investment covers all costs related to the pipeline laying, including pipes fee, production cost,

the maximum design flow velocity of the ductile iron pipe shall not exceed 2.5 ~ 3.0m/s; for transmission

transportation costs, anti-corrosion costs for internal and external walls, construction cost and greening-

of turbid raw water, the minimum flow velocity can not be less than 0.6 m/s so as to avoid precipitation of

compensation.

suspended matter in water. In the actual design work, the flow velocity shall be selected in combination

2)Annual maintenance cost of pipeline

with local economic conditions, as well as the cost of the pipe network and the operation and management

Maintenance costs is discounted according to the calculation period, their NPV can be summed. The sum of

costs.

NPV of pipeline maintenance costs is calculated as the formula below:

CeNPVNPV sum of electricity expenses of each year within calculation period ($ 10,000)

Meanwhile, the diameter of pipes shall be selected on the basis of head loss. Through a lot of researches

and tests, Xinxing has reviewed the absolute roughness of various lining, and accordingly developed the

Cm(1+i)

CmNPV=

-t

t=1

hydraulic calculation table of ductile iron pipes with different lining for the reference of design department.

Where: Cm Annual pipeline maintenance fee, usually counted as 1% of the pipeline investment

4.2.2 Determination of the economic velocity

n Calculation period, generally 20 years

There are many different methods to calculate economic velocity, all countries have their own calculation

i Discount rate, generally 6 ~ 10% per year

methods. For water pipeline of large-scale supply & drainage project, the NPV method is usually adopted to

3)Annual electricity expenses for opeartion of pipeline in different diameters are calculated with supply water

determine the economical velocity and economical pipe diameter.

according to short and long term planning.


The sum of NPV of the annual electricity expenses for operation is calculated as the formula below:

4.2.2.1 Taken the maximum daily water amount as 100%, the statistics is conducted according to three
sections of daily water supply capacity, i.e. 100% ~ 90% (annual peak water supply period), 90% ~
80% (annual usual water supply period), <80% (annual trough period of supply). The statistics shall
cover the number and proportion of days as well as the proportion of the average daily supply quantity

CeNPV=

t1
t=1

Qr1H1f1+Qr2H2f2+Qr3H3f3
t

(1+i)

+
t=t1+1

Qr1H1f1+Qr2H2f2+Qr3H3f3
t

(1+i)

dx

24x365
102x86.4

in different water supply periods to the highest daily water supply quantity. Through research on the
variation characteristics of daily water supply within one year, the annual characteristics values of water
quantity variation can be summarized, which can reflect the magnitude of diurnal variation and variation

80

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

81

Where Q. Q short- and long-term planning of water consumption respectively with unit in m3/d
r1, r2, r3 - ratios of the annual peak water-supply period, usual water-supply period and trough water-

4.3 Selection of piping system


4.3.1 Types of pipeline system

supply period to the whole year respectively;


f1, f2, f3 ratios of the average daily supply water in the peak period, usual period, trough period

Gravity piping system

to the maximum daily supply water respectively


H1, H2, H3 Pipe head losses of average daily supply water in the anuual peak period, usual

Maximum static head

H.W.L
L.W.L

period and trough period in recent years respectively with unit in m

Reservoir

H1 H2 H3 Pipe head losses of average daily supply water in the anuual peak period, usual

Minimum hydraulic gra

dient line

Pipe

period and trough period in long term respectively with unit in m;


- efficiency of pump and motor
1 ~ t1 - Recent calculation years

Diagram of gravity piping system

(t1 +1 ~ n) - Forward calculation years


d - Integrated electric price (RMB/kwh)

If the starting point of a pipeline is higher than its termination point, and the height difference between
two points is larger than sum of total pipeline head loss and the smallest service water head of the most

4.2.2.3 Formula to calculate pump shaft power

unfavorable user, then the pipeline can work by gravitational flow.

The pump shaft power is related to the routine operating cost of pipeline project, which depends on the size

This piping system is featured as following:

of pipe and material of the inner wall. Therefore, it shall be concerned during the engineering design. Its

1)No power needed;

formula is:

2)Less costs for facilities, operation and maintenance;

P=0.0098 x

Q x ELT

3)Free failure during use and convenient maintenance;

Design principle of gravity piping system: Accelerate the flow rate by means of water head difference as
possible, namely, the pipe with the minimum diameter shall be used to reduce material cost and construction

Where: P - Pump shaft power (kw)

costs under the condition of meeting the requirements of water-consuming unit.

- Efficiency of Pump motor

H.W.L
L.W.L

ELT - Total Hydraulic Elevation (m)

Q - Flow rate (l/s)


Pump

Reservoir

Maximum static head


Minimum hydrauli
c gradient line

Pipe

H = Total head of pump

Pressure piping system

Diagram of pressure piping system

If the starting point of the pipeline is not high enough and the water can not be supplied by gravity flow, it is
necessary to use the booster pump which delivers water to the water supply location.
This piping system has the following characteristics:
1)The water pressure can be easily controlled;
2)It is less affected by terrain conditions, so the pipeline route is subject to less restriction.
3)Continous power input is needed. Thus, during pipeline design, various designing options shall be
compared, and the solution with minimum sum of pipeline construction and management costs during whole
payback period of the entire project shall be selected.
82

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

83

4.3.2 Principle of pipeline design


Pipeline shall fully utilize water elevation difference, and the gravity supply is preferred in combination

4.3.3 General requirements for pipeline


layout
The vent (intake) valves shall be installed at

with conditions along the line. If the pressured water supply is needed due to the terrain or pipe system

relatively and absolutely high points in the pipeline; the

layout, the stages and methods of pressure boost, booster stations shall be determined according to the

drain pipes and sluice valve shall be arranged at the low

equipment selection, analysis on operation cost, as well as the technical and economic comparison.

position of pipeline;

During the pipeline selection, it is necessary to combine the near and far terms and consider possibility

For pressure water pipelines, it is necessary to

of implementation by stage.

analyze possibility of water hammer; if necessary, the

The design and laying of pipeline shall put all points along the pipeline under the minimum hydraulic

measures shall be taken to eliminate water hammer;

gradient. For pressure pipeline, it shall be generally below the water hydraulic gradient line under different

4.4 The calculation of head


losses

water supply conditions.


H.W.L

Start

L.W.L

The energy must be added to overcome the head loss

mini

mum

hydr

aulic

during the water delivery. Head loss is related with the


grad

ient

The

following factors:
Inner friction of water (depends on its viscosity);
Water friction along the pipes wall(linked to the
roughness);
Local changes to flow (elbows, joints, etc.).
Head loss consists of the linear loss and local loss.

Examples of improper piping design

For the long-distance water pipelines, the linear loss

When the certain points of the pipeline are inevitably higher than the minimum hydraulic gradient,

accounts for over 90% of whole energy loss, while

the pipe diameter shall be increased in the upstream section to reduce the friction loss so as to raise the

proportion of local loss generally does not exceed 10%.

minimum hydraulic gradient of the pipeline, and then the diameter of downstream pipeline shall be reduced.

4.4.1 Formula to calculate linear head


losses

H.W.L

Generally, the pipeline hydraulic calculation is based on

Start

uniform flow in the water supply project

L.W.L
imum h

gradien

4.4.1.1 Common empirical formula for linear


head losses calculation.

h2

ydraulic

h1

The min

1) Darcy formula
hf = *

2g

Where: hf Linear head loss (m)


vAverage flow velocity (m/s)
Example of changing the pipe diameter to accommodate a minimum hydraulic gradient

gGravitation consntant (m/s2)


DPipe diameter (m)
Length of the pipeline

84

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

85

The formula applies to the laminar and turbulent flow in the smooth or rough pipe with any cross-sectional

4.4.1.3 Minor head losses from fittings and valves

shapes, and the linear head loss factor in the formula is generally calculated by C. F. Colebrook formula.

The minor head losses from fittings (elbows, tees, etc.) and valves accounts for less proportion in the total

C.F. Colebrook formula:

head losses in a long pipeline: For a long-distance waterline, the head losses from pipe fittings can be

=-21og(

k
3.7D

2.51
Re

estimated as 5% ~ 10% of the linear losses of the pipeline according to number of fittings; however, for the

pipeline with short length and higher flow rate, the head losses from fittings may be relatively larger, which
Hf=

Where: linear head loss factor


k equivalent roughness of pipeline (mm)

1.8518

(3.5875 Q/ChD2.63)

shall be considered. The local head losses of fittings can be calculated by the following formula:
hj =

Where: Hf pipe head loss (m)

Dpipe diameter (mm)

Chhazen-Willian factor

Where: hjminor head losses (m)

Rereynolds number

D pipe diameter (m)

minor head loss factor

Q pipeline flow (m3/s)

vvelocity (m/s)

gacceleration of gravity (m/s2)

2) Hazen-Willian formula

pipe length (m)

v
2g

Minor Head Losses Factor

4.4.1.2 Hydraulic friction coefficient


T he hydraulic friction coefficient is one of important technical parameters during the fluid transport

No.

Item

Cross section with


sudden expansion

Cross section with


sudden reduction

drawing

value and description

A2

engineering design, which directly affects the accuracy of the hydraulic calculation.
No matter in Darcy Formula or Hazen - William Formula, the difference of pipe materials is reflected on the
absolute roughness of the inner wall. In each formula, the value of the roughness correlation coefficient is
an important factor affecting the calculating results.
Generally, the cement mortar is selected as the lining material of ductile iron pipe. The cement mortar

A1
1-

Pipe outlet

lining have been smooth, even and flat with strong bonding with the wall and sound hydraulic performance.

A2

1-

=0.5

Flow into channel,

A1

= 1-

A1

A2

Flow into tank, =1.0

Xinxing has conducted a series of tests on friction coefficient and checked the surface roughness value k
and Hazen-Willian coefficientChof ductile iron pipes lined with different materials. For cement mortar lined
ductile iron pipe, a K value of 0.03 can be used; however, for actual piping design purposes, the values of
friction coefficient are recommended for different lining materials as table belows:

=K
4

Round diverging pipe

A2
A1

-1

8
0.14

e/d

e/d

0.7
0.44

10
0.16

15
25
0.30 0.62

Recommended Friction Coefficient for Different Linings


Pipe

86

Ranges of friction coefficient


5

Sluice valve

0.2
35
0.8
0.17

0.4
4.6
0.9
0.0

0.6
0.98
1.0
0

Pipeline equivalent roughness k (mm)

Hazen-Willian factor Ch

PU lining

0.03~0.05

140~145

Sealing coat of cement mortar lining

0.05~0.07

133~137

For the minor losses of the valve, please consult suppliers of valves; for calculation of other types of local

cement mortar lining

0.07~0.1

125~130

losses, please contact our engineer.

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

87

4.4.2 Linenr head losses

Table of Head Loss of DN100 Ductile Iron Pipes With Different Lining Materials

To meet the relevant design needs, we have calculated the head losses of ductile iron pipe lined with
cement mortar and 1mm polyurethane in thickness under the following assumptions, which are shown in the
table below in details(where, hydraulic gradient J is the head losses for unit length of pipeline, thus, J =

hf

Q(l/s)

J(m/km)

Assumptions for head loss calculation include:


1)Full pipe flow

Cement mortar lining


(k=0.1mm)
V(m/s)

Epoxy sealing coat


(k = 0.07mm)
J(m/km)

V(m/s)

Polyurethane (PU) lining


(k=0.05mm)
J(m/km)

V(m/s)

4.0

3.19

0.51

3.09

0.51

2.26

0.45

4.5

3.97

0.57

3.82

0.57

2.81

0.51

2)Equivalent roughness coefficient k of pipeline:

5.0

4.84

0.64

4.66

0.64

3.40

0.57

5.5

5.79

0.70

5.56

0.70

4.04

0.62

k = 0.1mm for cement mortar lining

6.0

6.83

0.76

6.53

0.76

4.75

0.68

k = 0.07mm for epoxy sealing coat of cement mortar lining

6.5

7.94

0.83

7.59

0.83

5.52

0.74

k = 0.05mm for polyurethane lining


3)Water temperature = 18 , water kinematic viscosity = 1.06 10-6 (m2/s)
4)ID of Pipe: DN value of pipe nominal diameter

7.0

9.13

0.89

8.72

0.89

6.31

0.79

7.5

10.43

0.95

9.92

0.95

7.17

0.85

8.0

11.77

1.02

11.24

1.02

8.08

0.91

8.5

13.22

1.08

12.57

1.08

9.08

0.96

9.0

14.76

1.15

14.02

1.15

10.08

1.02

9.5

16.37

1.21

15.55

1.21

11.17

1.08

10.0

18.05

1.27

17.06

1.27

12.26

1.13

10.5

19.81

1.34

18.72

1.34

13.44

1.19

11.0

21.65

1.40

20.45

1.40

14.68

1.25

11.5

23.55

1.46

22.35

1.46

15.96

1.30

12.0

25.52

1.53

24.21

1.53

17.29

1.36

12.5

27.69

1.59

26.14

1.59

18.67

1.42

13.0

29.81

1.66

28.14

1.66

20.09

1.47

13.5

32.15

1.72

30.34

1.72

21.55

1.53

14.0

34.41

1.78

32.47

1.78

23.17

1.59

14.5

36.92

1.85

34.66

1.85

24.73

1.64

15.0

39.32

1.91

37.09

1.91

26.33

1.70

15.5

41.99

1.97

39.40

1.97

28.11

1.76

16.0

44.53

2.04

41.99

2.04

29.79

1.81

16.5

47.35

2.10

44.43

2.10

31.52

1.87

17.0

50.27

2.16

47.16

2.16

33.46

1.93

17.5

53.01

2.23

49.98

2.23

35.27

1.98

18.0

56.09

2.29

52.61

2.29

37.31

2.04

18.5

59.24

2.36

55.57

2.36

39.20

2.10

19.0

62.19

2.42

58.31

2.42

41.35

2.15

19.5

65.51

2.48

61.42

2.48

43.55

2.21

20.0

68.91

2.55

64.61

2.55

45.57

2.27

20.5

72.05

2.61

67.54

2.61

47.87

2.32

21.0

75.61

2.67

70.87

2.67

49.97

2.38

22.0

82.98

2.80

77.78

2.80

54.84

2.49

23.0

90.26

2.93

84.58

2.93

59.61

2.61

75.34

2.95

26.0

* Head (in meters) of the fluid as it flows through a standard kilometer of the relevant pipe.

88

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

89

Table of Head Loss of DN400 Ductile Iron Pipes With Different Lining Materials

Q(l/s)

Cement mortar lining


(k=0.1mm)

Epoxy sealing coat


(k = 0.07mm)

Table of Head loss of DN600 Ductile Iron Pipes With Different Lining Materials

Polyurethane (PU) lining


(k=0.05mm)

Q(l/s)

Cement mortar lining


(k=0.1mm)

Epoxy sealing coat


(k = 0.07mm)

Polyurethane (PU) lining


(k=0.05mm)

J(m/km)

V(m/s)

J(m/km)

V(m/s)

J(m/km)

V(m/s)

J(m/km)

V(m/s)

J(m/km)

V(m/s)

J(m/km)

V(m/s)

60

0.51

0.48

0.50

0.48

0.44

0.46

140

0.34

0.50

0.33

0.50

0.30

0.48

65

0.59

0.52

0.58

0.52

0.51

0.50

160

0.43

0.57

0.42

0.57

0.39

0.55

70

0.69

0.56

0.67

0.56

0.59

0.54

180

0.54

0.64

0.53

0.64

0.48

0.62

75

0.78

0.60

0.76

0.60

0.67

0.57

200

0.66

0.71

0.64

0.71

0.58

0.69

80

0.88

0.64

0.85

0.64

0.76

0.61

220

0.79

0.78

0.76

0.78

0.70

0.76

85

0.99

0.68

0.95

0.68

0.85

0.65

240

0.93

0.85

0.90

0.85

0.82

0.83

90

1.10

0.72

1.06

0.72

0.94

0.69

260

1.08

0.92

1.05

0.92

0.95

0.90

95

1.22

0.76

1.18

0.76

1.04

0.73

280

1.25

0.99

1.20

0.99

1.10

0.96

100

1.34

0.80

1.30

0.80

1.14

0.76

300

1.42

1.06

1.37

1.06

1.25

1.03

110

1.61

0.88

1.55

0.88

1.37

0.84

320

1.60

1.13

1.55

1.13

1.41

1.10

120

1.90

0.95

1.83

0.95

1.60

0.92

340

1.81

1.20

1.74

1.20

1.58

1.17

130

2.22

1.03

2.12

1.03

1.87

0.99

360

2.02

1.27

1.93

1.27

1.76

1.24

140

2.54

1.11

2.44

1.11

2.16

1.07

380

2.23

1.34

2.14

1.34

1.95

1.31

150

2.91

1.19

2.79

1.19

2.44

1.15

400

2.47

1.41

2.37

1.41

2.14

1.38

160

3.29

1.27

3.15

1.27

2.76

1.22

420

2.71

1.49

2.60

1.49

2.36

1.45

170

3.70

1.35

3.53

1.35

3.09

1.30

440

2.97

1.56

2.85

1.56

2.57

1.52

180

4.12

1.43

3.93

1.43

3.45

1.38

460

3.23

1.63

3.09

1.63

2.79

1.58

190

4.59

1.51

4.38

1.51

3.81

1.45

480

3.51

1.70

3.37

1.70

3.04

1.65

200

5.05

1.59

4.83

1.59

4.22

1.53

500

3.81

1.77

3.63

1.77

3.27

1.72

210

5.57

1.67

5.28

1.67

4.62

1.61

520

4.09

1.84

3.92

1.84

3.54

1.79

220

6.07

1.75

5.80

1.75

5.04

1.68

540

4.42

1.91

4.20

1.91

3.78

1.86

230

6.64

1.83

6.30

1.83

5.51

1.76

560

4.75

1.98

4.52

1.98

4.07

1.93

240

7.18

1.91

6.86

1.91

5.96

1.84

580

5.06

2.05

4.84

2.05

4.37

2.00

250

7.79

1.99

7.39

1.99

6.46

1.91

600

5.41

2.12

5.15

2.12

4.64

2.07

260

8.37

2.07

7.99

2.07

6.94

1.99

620

5.78

2.19

5.49

2.19

4.95

2.14

270

9.03

2.15

8.62

2.15

7.49

2.07

640

6.12

2.26

5.85

2.26

5.28

2.20

280

9.71

2.23

9.20

2.23

7.99

2.14

660

6.50

2.33

6.23

2.33

5.57

2.27

290

10.42

2.31

9.87

2.31

8.57

2.22

680

6.90

2.41

6.56

2.41

5.91

2.34

300

11.07

2.39

10.57

2.39

9.11

2.29

700

7.32

2.48

6.95

2.48

6.26

2.41

310

11.83

2.47

11.21

2.47

9.73

2.37

720

7.74

2.55

7.35

2.55

6.57

2.48

320

12.60

2.55

11.94

2.55

10.37

2.45

740

8.12

2.62

7.77

2.62

6.94

2.55

330

13.40

2.63

12.70

2.63

10.94

2.52

760

8.56

2.69

8.13

2.69

7.32

2.62

340

14.13

2.71

13.39

2.71

11.62

2.60

780

9.02

2.76

8.57

2.76

7.71

2.69

350

14.98

2.79

14.18

2.79

12.31

2.68

800

9.49

2.83

9.01

2.83

8.05

2.76

360

15.84

2.86

15.01

2.86

12.93

2.75

820

9.97

2.90

9.47

2.90

8.46

2.82

370

16.74

2.94

15.85

2.94

13.66

2.83

840

10.46

2.97

9.93

2.97

8.88

2.89

380

17.65

3.02

16.60

3.02

14.41

2.91

* Head (in meters) of the fluid as it flows through a standard kilometer of the relevant pipe.

* Head (in meters) of the fluid as it flows through a standard kilometer of the relevant pipe.

90

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

91

Table of Head Loss of DN1000 Ductile Iron Pipes With Different Lining Materials

Q(m3/s)

Cement mortar lining


(k=0.1mm)

Epoxy sealing coat


(k = 0.07mm)

Table of Head Loss of DN1600 Ductile Iron Pipes With Different Lining Materials

Polyurethane (PU) lining


(k=0.05mm)

Cement mortar lining


(k=0.1mm)

Epoxy sealing coat


(k = 0.07mm)

Polyurethane (PU) lining


(k=0.05mm)

J(m/km)

V(m/s)

J(m/km)

V(m/s)

J(m/km)

V(m/s)

0.10

0.50

0.10

0.50

0.10

0.49

0.22

1.1

0.13

0.55

0.12

0.55

0.11

0.54

0.62

0.26

1.2

0.15

0.60

0.14

0.60

0.13

0.59

0.70

0.69

0.32

1.3

0.17

0.65

0.17

0.65

0.16

0.63

0.40

0.76

0.75

0.37

1.4

0.20

0.70

0.19

0.70

0.18

0.68

0.83

0.47

0.83

0.81

0.43

1.5

0.23

0.75

0.22

0.75

0.20

0.73

0.55

0.89

0.54

0.89

0.87

0.50

1.6

0.26

0.80

0.25

0.80

0.23

0.78

0.75

0.63

0.95

0.61

0.95

0.94

0.57

1.7

0.29

0.85

0.28

0.85

0.26

0.83

J(m/km)

V(m/s)

J(m/km)

V(m/s)

J(m/km)

V(m/s)

0.4

0.19

0.51

0.19

0.51

0.50

0.18

0.45

0.24

0.57

0.23

0.57

0.56

0.5

0.29

0.64

0.28

0.64

0.55

0.35

0.70

0.34

0.6

0.41

0.76

0.65

0.48

0.7

0.8

0.71

1.02

0.69

1.02

1.00

0.64

1.8

0.32

0.90

0.31

0.90

0.29

0.88

0.85

0.80

1.08

0.77

1.08

1.06

0.72

1.9

0.35

0.94

0.34

0.94

0.32

0.93

0.9

0.89

1.15

0.86

1.15

1.12

0.80

0.39

0.99

0.38

0.99

0.35

0.98

0.95

0.99

1.21

0.96

1.21

1.19

0.88

2.1

0.43

1.04

0.42

1.04

0.39

1.02

1.09

1.27

1.05

1.27

1.25

0.97

2.2

0.47

1.09

0.45

1.09

0.42

1.07

1.05

1.20

1.34

1.16

1.34

1.31

1.07

2.3

0.51

1.14

0.49

1.14

0.46

1.12

1.1

1.31

1.40

1.26

1.40

1.37

1.17

2.4

0.55

1.19

0.53

1.19

0.49

1.17

1.15

1.44

1.46

1.37

1.46

1.44

1.27

2.5

0.60

1.24

0.58

1.24

0.54

1.22

1.2

1.55

1.53

1.49

1.53

1.50

1.38

2.6

0.65

1.29

0.62

1.29

0.58

1.27

1.25

1.68

1.59

1.62

1.59

1.56

1.49

2.7

0.69

1.34

0.67

1.34

0.62

1.32

1.3

1.81

1.66

1.74

1.66

1.62

1.60

2.8

0.74

1.39

0.72

1.39

0.66

1.37

1.35

1.95

1.72

1.87

1.72

1.69

1.73

2.9

0.80

1.44

0.77

1.44

0.71

1.41

1.4

2.10

1.78

2.00

1.78

1.75

1.84

0.85

1.49

0.82

1.49

0.76

1.46

1.45

2.25

1.85

2.15

1.85

1.81

1.98

3.2

0.96

1.59

0.92

1.59

0.86

1.56

1.5

2.39

1.91

2.30

1.91

1.87

2.11

3.4

1.08

1.69

1.03

1.68

0.96

1.66

1.55

2.55

1.97

2.45

1.97

1.93

2.24

3.6

1.21

1.79

1.14

1.78

1.07

1.76

1.6

2.72

2.04

2.59

2.04

2.00

2.38

3.8

1.35

1.89

1.27

1.88

1.19

1.85

1.65

2.89

2.10

2.76

2.10

2.06

2.54

1.48

1.99

1.39

1.97

1.31

1.95

1.7

3.04

2.16

2.93

2.16

2.12

2.67

4.2

1.63

2.09

1.53

2.07

1.43

2.05

1.75

3.23

2.23

3.07

2.23

2.18

2.83

4.4

1.79

2.19

1.67

2.17

1.57

2.15

1.8

3.41

2.29

3.25

2.29

2.25

2.99

4.6

1.94

2.29

1.81

2.26

1.71

2.24

1.85

3.61

2.36

3.44

2.36

2.31

3.16

4.8

2.12

2.39

1.96

2.36

1.86

2.34

1.9

3.80

2.42

3.62

2.42

2.37

3.31

2.30

2.49

2.12

2.45

2.01

2.44

1.95

3.97

2.48

3.82

2.48

2.43

3.48

5.2

2.48

2.59

2.27

2.55

2.16

2.54

4.18

2.55

3.98

2.55

2.50

3.66

5.4

2.65

2.69

2.44

2.64

2.33

2.63

2.1

4.61

2.67

4.39

2.67

2.62

4.00

5.6

2.85

2.79

2.61

2.74

2.50

2.73

2.2

5.06

2.80

4.82

2.80

2.75

4.39

5.8

3.06

2.88

2.80

2.83

2.69

2.83

2.3

5.49

2.93

5.22

2.93

2.87

4.80

3.28

2.98

2.96

2.93

2.85

2.93

2.4

5.97

3.06

5.69

3.06

3.00

5.18

6.2

3.50

3.08

3.15

3.02

3.04

3.02

* Head (in meters) of the fluid as it flows through a standard kilometer of the relevant pipe.

92

Q(m3/s)

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

* Head (in meters) of the fluid as it flows through a standard kilometer of the relevant pipe.

Xinxing Ductile Iron Pipes Technical Manual

93

4.5 Prevention and calculation of water hammer

Table of Head Loss of DN2000 Ductile Iron Pipes With Different Lining Materials

Q(m3/s))

Cement mortar lining


(k=0.1mm)

Epoxy sealing coat


(k = 0.07mm)

Polyurethane (PU) lining


(k=0.05mm)

V(m/s)

J(m/km)

V(m/s)

J(m/km)

V(m/s)

1.6

0.08

0.51

0.08

0.51

0.08

0.50

1.8

0.10

0.57

0.10

0.57

0.10

0.56

0.13

0.64

0.12

0.64

0.12

0.63

2.2

0.15

0.70

0.15

0.70

0.14

0.69

2.4

0.18

0.76

0.18

0.76

0.17

0.75

collapsing).

2.6

0.21

0.83

0.21

0.83

0.19

0.81

Cutoff water hammer (due to cavities collapsing) when pressure somewhere of the pipeline is lower

2.8

0.24

0.89

0.24

0.89

0.22

0.88

than the saturated vapor pressure under the current water temperature, water will vaporize, destroying

0.28

0.95

0.27

0.95

0.25

0.94

3.2

0.31

1.02

0.30

1.02

0.29

1.00

continuity of water flow and causing the water column separation, which forms acavity section here. When

3.4

0.35

1.08

0.34

1.08

0.32

1.07

3.6

0.39

1.15

0.38

1.15

0.36

1.13

3.8

0.43

1.21

0.42

1.21

0.40

1.19

0.48

1.27

0.46

1.27

0.43

1.25

4.2

0.53

1.34

0.51

1.34

0.48

1.32

4.4

0.58

1.40

0.56

1.40

0.52

1.38

4.6

0.63

1.46

0.61

1.46

0.57

1.44

4.8

0.68

1.53

0.66

1.53

0.61

1.50

0.74

1.59

0.71

1.59

0.67

1.57

5.2

0.80

1.66

0.77

1.66

0.71

1.63

5.4

0.86

1.72

0.82

1.72

0.77

1.69

5.6

0.92

1.78

0.89

1.78

0.83

1.75

5.8

0.99

1.85

0.95

1.85

0.88

1.82

1.06

1.91

1.01

1.91

0.94

1.88

6.2

1.13

1.97

1.08

1.97

1.01

1.94

6.4

1.19

2.04

1.15

2.04

1.06

2.00

6.6

1.27

2.10

1.22

2.10

1.13

2.07

6.8

1.34

2.16

1.28

2.16

1.20

2.13

If the pipeline pressure drops and affects normal water supply, sewage will be drawn in at the pipeline

1.42

2.23

1.36

2.23

1.27

2.19

breakage due to a negative pressure, and thus affects water quality.

7.2

1.51

2.29

1.44

2.29

1.33

2.26

7.4

1.58

2.36

1.52

2.36

1.41

2.32

7.6

1.66

2.42

1.60

2.42

1.48

2.38

7.8

1.75

2.48

1.67

2.48

1.56

2.44

1.84

2.55

1.76

2.55

1.64

2.51

8.4

2.03

2.67

1.94

2.67

1.79

2.63

8.8

2.23

2.80

2.13

2.80

1.97

2.76

elevation of the pipeline being higher than the

9.1

2.36

2.90

2.28

2.90

2.11

2.85

minimum pressure line when water hammer occurs,

9.5

2.58

3.02

2.46

3.02

2.27

2.98

as shown in figure below. The pipeline layout shall not

Xinxing Ductile Iron Pipes Technical Manual

cause water pressure to rise dramatically, which will damage pump, valve and pipe, etc.; conversely, if the
water pressure drops dramatically, it can also form phenomenon of cutoff water hammer (due to cavities

the separated water column is re-bridged or the cavity section is re-filled with water flow, violent collision
between two water columns can produce a high-pressure cutoff water hammer (due to cavities collapsing).
Water hammer can occur in the gravity pipeline or pressure (deliveried by pump) pipeline.

4.5.2 Causes of water hammer


The situations, such as starting and stopping the pump, starting and closing the valve or regulating the
flow through changing pump speed or blade angle, especially for swift operations which cause the water
velocity to change dramatically ;
Accidentally stopping the pump, i.e., sudden power interruption of the running pump , mainly caused by
the distribution system malfunction, misoperation, and lightning, etc.

4.5.3 Hazards of water hammer


The dramatically increased pressure may damage pump, pipe and valve, etc.;
If a pump is running with too high reverse rotation speed or coincide with critical rotation speed of the
unit, the pump unit may be caused to vibrate severely;

4.5.4 Prevention for water hammer

N
H1

Make reasonable layout of the pipeline, in order

H2

to avoid negative internal pressure


When laying the pipelines, it is necessary to avoid

Pressure line at
normal working condition
R

C
F

B
R

A
Pump Check valve

Pressure line at normal


working condition at B

XINXING PIPES

interruption of water flow in the pressure pipeline system, and spread in the pipeline. Water hammer may

Maximum vacuum
at point B

Water hammer refers dramatical pressure change of water flow in the pipeline caused by sudden

Maximum pressure drop

* Head (in meters) of the fluid as it flows through a standard kilometer of the relevant pipe.

94

4.5.1 Overview

J(m/km)

be A-B-C. The correct piping layout shall be A-B-C.


Xinxing Ductile Iron Pipes Technical Manual

95

Prevent the pressure from rising too highly:


1)Set an water hammer arrestor
2)Set an air cylinder (for the shorter pipeline or the smaller pipe diameter)
3)Adopt slow closing check valve or hydraulic control check valve (special devices to eliminate
water hammer due to pump-stopping)

Schematic diagram of air cylinder

4.5.5 Simplified calculation of water hammer


4.5.5.1 Pressure wave velocity
fied water to water-consuming sec

a=

y
g

1
K

D
Ee

Where, a pressure wave velocity (m / sec)


specific weight of water (= 10,000N/m3)
g acceleration of gravity (= 9.8m/sec2)
K bulk modulus of elasticity of water (= 2.07 109N/m2)
E elasticity modulus of the pipe wall material (E= 1.71011N/m2 for ductile
iron pipe)
D diameter of the pipe (m)
e wall thickness of the pipe (m)
If the diameter and wall thickness along the entire pipeline are uneven, then, a1, a2 ...... and
an shall be calculated respectively for the length (L1, L2, ...... or Ln) of each section with same
diameter and wall thickness. Then average value for overall pressure wave velocity can be
calculated according to the following formula:
a=

L
Ln
an

96

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

97

4.5.5.2 The formula to calculate water hammer phase is as following:


Time required for the water hammer wave to be transmitted one round in the pipeline is 2L/a, namely phase
or water hammer phase.
Tf =

2L
a

4.6 Depth of cover for pipeline


The theoretical allowable depths of cover for pipes with different pressure levels are calculated in
accordance with ISO 10803-2011, and three different traffic load factor values, six soil groups and five

(s)

types of pipe trenches are assumed. Some calculation results are shown in the table below, which can be

Where, Tf water hammer phase (s)

referred to by various designers.

In general, if the allowable depths of cover is not adequate in height, pipes with higher pressure level shall

L pipe length (m)

4.5.5.3 Simplified calculation method of water hammer resulting from valve opening or
closing
1) Simple calculation on water hammer resulting from swift opening or closing valve
(Under the conditions of the valve switching time: T <Tf )

be selected to meet the requirements of height depths cover.


Traffic load factor -
The following values are given:
1.5:this is the general cases,except access roads;
0.75:road where truck traffic is prohibited;

a
H -H0= (V-VO)
g

0.5:all other cases

2) Simple calculation on water hammer resulting from slowly opening or closing valve
(Under the conditions of the valve switching time: T Tf )

In this case where a national standard exists for the traffic loadings, the value of may be given as follows:
=P/100
Where: P is the wheel load, in kilonewtons, for a particular type of load according to the respective national

2La
H -H0= (V-VO)
gt

standard.
For all pipelines, shall be designed as 0.5 at least, while the pipelines adjacent to the road shall be

Where, HoPressure under the stable flow state (m)

designed to withstand the full loads of road.

vo flow velocity under the stable flow state (m / sec.)

Hpressure at a given moment after valve operation (m)

v flow velocity at a given moment after valve operation (m / sec.)

Note 1: When H < 0.3m, the formula is not applicable


Note 2: For the pipelines buried under the railway or airport or places subjected to heavy traffic load special

When all valves are closed and v = 0, H-Ho=a.vo/g is the maximum additional pressure resulting from water

requirements shall be added according to the respective national standards and regulations construction.

hammer.

Soil classification

These simplified formulas provide assessment methods for maximum water hammer with the issues must

The following soil groups classify different soils for embedments, i.e. soils which are used for placement

be considered as below:

in the trench surrounding the pipe, compacted or uncompacted, to provide support for the pipeline. These

Assumptions: there are protection measures available for pipeline against water hammer and the head

groups classify naturally occurring soils as well as manufactured materials. The groups are also for use in

loss is negligible. In addition, no constraint is considered, such as pump turbine operation, pressure drop of

classifying undisturbed trench wall materials.

the saturation vapor, and so on.

Soil group A: angular graded stone (6 mm to 40 mm), also including a number of fill materials which have
regional significance, such as crushed stone, crushed gravel, pea gravel and crushed shells.

4.5.5.4 Simplified calculation of pump-stopping water hammer


Calculation of the pump-stopping water hammer is very complex, which can be done only with the help of
a computer. For the pump-stopping water hammer of most water pipeline, the designer can directly use
Parmakian nomogram of pump-stopping water hammer.
After all, the analysis and calculation on water hammer of the pump station is to regulate management and
operation of pump station and maintain the units in good conditions. In practice, the operation specification
shall be followed to operate and manage the pump station. It is forbidden to take place mal-operations. The

Soil group B: coarse; grained soils with little or no fines. No particles larger than 40 mm.
Soil group C: coarse; grained soils with fines and fine-grained soils with medium to no plasticity, with
more than 25 % coarse particles, liquid limit less than 50 %.
Soil group D: fine; grained soils with medium to no plasticity, with less than 25 % coarse particles, liquid
limit less than 50 %.
Soil group E: fine; grained soils with medium to high plasticity, liquid limit greater than 50 %.

factors leading to water hammer shall be found in time to eliminate the hidden dangers, so that the pump
station can be safely and economicaly operated.
98

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

99

Soil group F: organic soils.

8,8/8,8/8,6

9,1/9,0/8,9

10,5/10,5/10,4

13,8/13,7/13,7

19,9/19,9/19,8

7,1/7,0/6,8

7,3/7,3/7,0

8,7/8,7/8,5

11,2/11,2/11,1

15,6/15,5/15,5

5,3/5,3/5,0

6,1/6,0/5,8

6,9/6,8/6,6

8,7/8,6/8,4

12,7/12,7/12,6

4,8/4,7/4,3

5,5/5,4/5,2

6,3/6,2/6,0

8,0/7,9/7,8

10,5/10,5/10,3

E/F

4,2/4,0/3,7

4,3/4,2/3,8

4,4/4,3/4,0

4,8/4,7/4,3

5,4/5,3/5,1

trench type 4: embedment with medium compaction, greater than 85 % standard Proctor density;

7,9/7,9/7,7

8,2/8,1/8,0

9,6/9,6/9,5

12,8/12,8/12,7

18,8/18,8/18,7

trench type 5: embedment with high compaction, greater than 90 % standard Proctor density.

6,2/6,2/5,9

6,4/6,3/6,1

7,8/7,8/7,6

10,3/10,2/10,1

14,5/14,4/14,4

4,5/4,4/4,0

5,2/5,1/4,8

6,0/5,9/5,7

7,7/7,6/7,4

11,6/11,6/11,5

3,9/3,7/3,3

4,6/4,5/4,2

5,4/5,3/5,0

7,0/7,0/6,8

9,4/9,4/9,3

E/F

3,3/3,1/2,6c

3,4/3,2/2,7c

3,5/3,3/2,9c

3,7/3,6/3,2

4,3/4,2/3,8

7,4/7,4/7,2

7,7/7,6/7,4

9,1/9,0/8,9

12,2/12,2/12,1

18,2/18,1/18,1

5,7/5,6/5,4

5,9/5,8/5,6

7,3/7,2/7,0

9,7/9,6/9,5

13,8/13,8/13,7

3,9/3,8/3,5

4,7/4,6/4,3

5,4/5,4/5,1

7,1/7,0/6,8

10,9/10,9/10,8

3,3/3,2/2,7c

4,1/4,0/3,6

4,8/4,8/4,4

6,4/6,4/6,2

8,8/8,7/8,6

2,8/2,7/ d

2,9/2,7/ d

3,2/3,0/2,5c

3,6/3,5/3,1

Type of pipe trench


trench type 1: embedment dumped

800

trench type 2: embedment with very light compaction, greater than 75 % standard Proctor density;
trench type 3: embedment with light compaction, greater than 80 % standard Proctor density;

NOTE: Pipes are normally placed on a flat-bottomed trench when a suitable uniform support can be

1000

achieved; in other cases, a layer of loose soil is used as lower bedding.

Allowable Depth of Cover for K9 Cement Mortar Lining Pipes Conforming to ISO 2531-1998
1200

Allowable Depth of Cover/m


DN/mm

100

200

300

500

100

XINXING PIPES

(=0.5/0.75/1.5)a

Soil Type
Trench Type 1

Trench Type 2

Trench Type 3

Trench Type 4

Trench Type 5

E/F

2,7/2,5/ d

50b/50b /50b

50b/50b /50b

50b/50b /50b

50b/50b /50b

50b/50b /50b

7,0/6,9/6,7

7,2/7,1/7,0

8,6/8,6/8,4

11,7/11,7/11,6

17,6/17,5/17,5

50b/50b /50b

50b/50b /50b

50b/50b /50b

50b/50b /50b

50b/50b /50b

5,3/5,2/4,9

5,4/5,3/5,1

6,8/6,8/6,5

9,2/9,1/9,0

13,3/13,2/13,1

50b/50b /50b

50b/50b /50b

50b/50b /50b

50b/50b /50b

50b/50b /50b

3,5/3,3/3,0

4,2/4,1/3,8

5,0/4,9/4,6

6,6/6,5/6,3

10,4/10,3/10,2

50b/50b

50b/50b

50b/50b

50b/50b

50b/50b

2,9/2,7/2,1c

3,6/3,5/3,1

4,3/4,3/3,9

5,9/5,9/5,7

8,2/8,2/8,0

/50b

/50b

/50b

/50b

1500

/50b

E/F

50b/50b /50b

50b/50b /50b

50b/50b /50b

50b/50b /50b

50b/50b /50b

E/F

2,2/2,0/ d

2,3/2,1/ d

2,4/2,2/ d

2,6/2,4/ d

3,0/2,9/2,3c

18.9/18.8/18.7

19.4/19.4/19.3

20.6/20.6/20.5

23.1/23.0/23.0

28.1/28.1/28.0

6,7/6,7/6,5

6,9/6,8/6,7

8,3/8,3/8,2

11,4/11,4/11,3

17,2/17,2/17,1

18.1/18.0/17.9

18.6/18.6/18.5

19.7/19.7/19.6

21.8/21.8/21.7

26.1/26.0/26.0

5,0/4,9/4,7

5,1/5,1/4,8

6,5/6,4/6,3

8,8/8,8/8,7

12,9/12,9/12,8

17.2/17.2/17.1

18.0/18.0/17.9

18.8/18.8/18.7

20.6/20.6/20.5

24.7/24.7/24.6

3,2/3,1/2,7

3,9/3,8/3,5

4,7/4,6/4,3

6,3/6,2/6,0

10,0/10,0/9,9

17.0/17.0/16.9

17.7/17.7/17.7

18.6/18.5/18.5

20.3/20.3/20.2

23.7/23.7/23.6

2,6/2,4/ d

3,3/3,2/2,8

4,0/4,0/3,7

5,6/5,6/5,3

7,8/7,8/7,7

E/F

16.7/16.7/16.6

17.2/17.2/17.1

17.7/17.7/17.6

18.8/18.8/18.7

21.3/21.2/21.2

E/F

1,9/1,7/ d

2,0/1,8/ d

2,1/1,9/ d

2,3/2,1/ d

2,7/2,5/1,9c

13.3/13.2/13.1

13.6/13.6/13.5

14.8/14.8/14.7

17.3/17.3/17.2

22.3/22.2/22.2

6,6/6,5/6,4

6,8/6,7/6,6

8,2/8,1/8,0

11,3/11,2/11,2

17,0/17,0/17,0

12.2/12.2/12.0

12.5/12.5/12.4

13.7/13.6/13.5

15.7/15.7/15.6

19.6/19.6/19.5

4,8/4,8/4,5

5,0/4,9/4,7

6,3/6,3/6,2

8,7/8,7/8,6

12,7/12,7/12,6

11.1/11.1/10.9

11.8/11.8/11.7

12.5/12.5/12.4

14.1/14.1/14.0

17.8/17.7/17.7

3,1/3,0/2,6

3,8/3,7/3,4

4,5/4,5/4,2

6,1/6,1/5,9

9,8/9,8/9,7

10.8/10.7/10.6

11.4/11.4/11.3

12.2/12.1/12.0

13.7/13.7/13.6

16.4/16.4/16.3

2,5/2,3/ d

3,2/3,1/2,7

3,9/3,8/3,5

5,5/5,4/5,2

7,7/7,6/7,5

E/F

10.4/10.4/10.2

10.7/10.7/10.5

11.0/11.0/10.9

11.8/11.7/11.6

13.3/13.3/13.1

E/F

1,8/1,6/ d

1,8/1,7/ d

2,0/1,7/ d

9.8/9.8/9.7

10.1/10.1/10.0

11.4/11.4/11.3

14.2/14.2/14.1

19,6/19,6/19,5

8.5/8.4/8.2

8.7/8.7/8.5

9.9/9.9/9.8

12,2/12,1/12,0

16,1/16,1/16,0

7.1/7.0/6.8

7.8/7.7/7.5

8.5/8.4/8.2

10,1/10,0/9,9

13,8/13,7/13,6

6.6/6.5/6.3

7.3/7.2/7.0

8.0/7.9/7.7

9,5/9,5/9,3

12,0/11,9/11,8

E/F

6.1/6.0/5.8

6.3/6.2/6.0

6.5/6.4/6.2

6,9/6,9/6,6

7,8/7,8/7,6

Xinxing Ductile Iron Pipes Technical Manual

1800

2000

2,1/1,9/

2,5/2,3/ d

Notes: a. The traffic load factors applicable to all burial depths are given as 0.5, 0.75 and 1.5;
b. The allowable burial depth exceeds 50 m;
c. The min burial depth must be more than 1 m;
d. Not recommended.

Xinxing Ductile Iron Pipes Technical Manual

101

Allowable Depth of Cover for Class-C Cement Mortar Lining Pipes Conforming to ISO 2531-1998
Allowable Depth of Cover/m
DN/mm

80

100

125

150

200

250

102

XINXING PIPES

300

(=0.5/0.75/1.5)a

Soil Type
Trench Type 1

Trench Type 2

Trench Type 3

Trench Type 4

Trench Type 5

39.4/39.4/39.4

40.5/40.5/40.5

42.1/42.1/42.0

45.5/45.5/45.4

d/d/d

38.9/38.9/38.9

40.0/40.0/40.0

41.6/41.5/41.5

44.7/44.7/44.7

d/d/d

38.4/38.4/38.3

39.7/39.7/39.6

41.0/41.0/41.0

44.0/44.0/43.9

d/d/d

38.2/38.2/38.2

39.5/39.5/39.4

40.8/40.8/40.8

43.8/43.8/43.7

49.9/49.9/49.8

E/F

38.1/38.1/38.0

39.2/39.2/39.1

40.3/40.3/40.3

42.8/42.8/42.8

48.4/48.4/48.3

27.3/27.3/27.2

28.1/28.1/28.0

29.3/29.3/29.3

32.1/32.1/32.0

37.8/37.8/37.8

26.7/26.7/26.5

27.4/27.4/27.4

28.7/28.7/28.6

31.2/31.2/31.1

36.3/36.3/36.2

26.1/26.1/26.0

27.0/27.0/27.0

28.0/28.0/28.0

30.3/30.3/30.2

35.2/35.2/35.2

25.9/25.8/25.8

26.8/26.8/26.7

27.8/27.8/27.8

30.0/30.0/30.0

34.5/34.4/34.4

E/F

25.7/25.6/25.6

26.4/26.4/26.3

27.2/27.2/27.1

28.9/28.9/28.8

32.6/32.6/32.6

19.9/19.9/19.8

20.4/20.4/20.3

21.6/21.6/21.5

24.0/24.0/23.9

29.0/29.0/29.0

19.1/19.1/19.0

19.7/19.7/19.6

20.8/20.8/20.7

22.9/22.9/22.8

27.1/27.1/27.1

18.4/18.4/18.3

19.2/19.2/19.1

20.0/20.0/19.9

21.8/21.8/21.7

25.9/25.9/25.8

18.2/18.1/18.0

18.9/18.9/18.8

19.7/19.7/19.6

21.5/21.5/21.4

25.0/24.9/24.8

E/F

17.9/17.9/17.8

18.4/18.4/18.3

19.0/18.9/18.9

20.2/20.2/20.1

22.8/22.8/22.7

14.9/14.9/14.8

15.4/15.3/15.2

16.4/16.4/16.3

18.8/18.7/18.7

23.4/23.4/23.4

14.0/14.0/13.9

14.5/14.4/14.3

15.5/15.5/15.4

17.5/17.4/17.4

21.2/21.2/21.1

13.2/13.1/13.0

13.9/13.8/13.7

14.6/14.5/14.4

16.1/16.1/16.0

19.7/19.7/19.6

12.9/12.8/12.7

13.6/13.5/13.4

14.3/14.2/14.1

15.8/15.8/15.7

18.6/18.6/18.5

E/F

12.8/12.5/12.4

12.9/12.9/12.8

13.3/13.3/13.2

14.2/14.1/14.0

16.0/1.06/15.9

10.9/10.8/10.7

11.2/11.1/11.0

12.3/12.3/12.1

14.7/14.7/14.6

19.5/19.4/19.4

9.8/9.7/9.6

10.1/10.0/9.9

11.1/11.1/11.0

13.1/13.0/12.9

16.7/16.6/16.6

8.7/8.6/8.4

9.3/9.2/9.1

10.0/9.9/9.8

11.4/11.4/11.3

14.8/14.8/14.7

8.3/8.2/8.0

8.9/8.9/8.7

9.6/9.5/9.4

11.0/11.0/10.8

13.4/13.4/13.3

E/F

7.9/7.9/7.7

8.1/8.1/7.9

8.4/8.3/8.2

8.9/8.9/8.7

10.1/10.1/9.9

10.6/10.5/10.4

10.9/10.8/107

12.0/12.0/11.9

14.6/14.5/14.4

19.4/19.4/19.3

9.4/9.4/9.2

9.7/9.6/9.5

10.8/10.8/10.6

12.8/12.8/12.7

16.5/16.4/16.3

8.2/8.2/8.0

8.9/8.8/8.7

9.6/9.5/9.4

11.1/11.0/10.9

14.5/14.5/14.4

7.8/7.8/7.6

8.5/8.4/8.3

9.2/9.1/8.9

10.6/10.6/10.4

13.0/13.0/12.9

E/F

7.5/7.4/7.2

7.7/7.6/7.4

7.9/7.9/7.7

8.4/8.4/8.2

9.5/9.5/9.3

Xinxing Ductile Iron Pipes Technical Manual

350

400

450

500

600

700

10.4/10.3/10.2

107/10.6/10.5

11.9/11.9/11.7

14.5/14.4/14.3

19.5/19.5/19.4

9.1/9.1/8.9

9.4/9.4/9.2

10.6/10.5/10.4

12.6/12.6/12.5

16.4/16.3/16.2

7.9/7.8/7.6

8.6/8.5/8.3

9.3/9.2/9.0

10.8/10.7/10.6

14.3/14.2/14.1

7.5/7.4/7.2

8.1/8.1/7.9

8.8/8.8/8.6

10.3/10.3/10.1

12.7/12.7/12.6

E/F

7.1/7.0/6.8

7.3/7.2/7.0

7.5/7.4/7.2

8.0/7.9/7.7

9.1/9.0/8.8

8.5/8.5/8.3

8.8/8.7/8.5

10.0/9.9/9.8

12.6/12.5/12.4

17.6/17.6/17.4

7.2/7.1/6.9

7.4/7.3/7.1

8.6/8.5/8.3

10.6/10.6/10.4

14.2/14.2/14.1

5.8/5.8/5.5

6.5/6.4/6.2

7.1/7.1/6.9

8.6/8.6/8.4

12.0/12.0/11.8

5.4/5.3/5.0

6.0/5.9/5.7

6.7/6.6/6.4

8.1/8.1/7.9

10.3/10.3/10.1

E/F

4.9/4.8/4.5

5.1/5.0/4.7

5.2/5.2/4.9

5.6/5.5/5.2

6.4/6.3/6.1

7.4/7.4/7.2

7.7/7.6/7.4

8.9/8.8/8.6

11.5/11.4/11.3

16.5/16.4/16.3

6.1/6.0/5.7

6.2/6.2/5.9

7.4/7.3/7.1

9.4/9.4/9.2

13.0/13.0/12.8

4.7/4.5/4.2

5.3/5.2/4.9

5.9/5.9/5.6

7.4/7.3/7.1

10.7/10.6/10.5

4.2/4.1/3.7

4.8/4.7/4.4

5.4/5.4/5.1

6.9/6.8/6.6

8.9/8.9/8.7

E/F

3.7/3.6/3.1

3.8/3.7/3.2

4.0/3.8/3.4

4.2/4.1/3.7

4.8/4.7/4.4

7.1/7.0/6.8

7.3/7.3/7.1

8.5/8.5/8.3

11.2/11.2/11.0

16.3/16.2/16.1

5.7/5.6/5.3

5.9/5.8/5.5

7.0/7.0/6.8

9.1/9.0/8.9

12.7/12.7/12.5

4.2/4.1/3.7

4.9/4.8/4.4

5.5/5.4/5.2

7.0/6.9/6.7

10.3/10.3/10.1

3.7/3.6/3.1

4.4/4.3/3.9

5.0/4.9/4.6

6.4/6.4/6.1

8.5/8.5/8.3

E/F

3.2/3.1/2.4 c

3.3/3.2/2.6c

3.5/3.3/2.7

3.7/3.6/3.1

4.3/4.1/3.8

7.2/7.1/6.9

7.4/7.4/7.2

8.7/8.6/8.5

11.4/11.4/11.3

16.6/16.6/16.5

5.7/5.7/5.4

5.9/5.8/5.6

7.1/7.1/6.9

9.2/9.2/9.0

12.9/12.9/12.8

4.2/4.1/3.7

4.9/4.8/4.5

5.6/5.5/5.2

7.0/7.0/6.8

10.5/10.4/10.3

3.7/3.6/3.1

4.4/4.3/3.9

5.0/5.0/4.6

6.5/6.4/6.2

8.6/8.6/8.4

E/F

3.2/3.1/2.4 c

3.3/3.2/2.6c

3.4/3.3/2.7

3.7/3.6/3.1

4.2/4.1/3.7

7.5/7.4/7.2

7.7/7.6/7.5

9.0/9.0/8.8

11.9/11.9/11.7

17.3/17.3/17.2

5.9/5.8/5.6

6.1/6.0/5.8

7.4/7.3/7.1

9.6/9.5/9.4

13.5/13.4/13.3

4.3/4.2/3.9

5.0/4.9/4.6

5.7/5.6/5.4

7.3/7.2/7.0

10.9/10.8/10.7

3.8/3.7/3.2

4.5/4.4/4.0

5.2/5.1/4.8

6.7/6.6/6.4

8.9/8.9/8.7

E/F

3.3/3.1/2.5c

3.4/3.2/2.6

3.5/3.3/2.8

3.7/3.6/3.1

4.3/4.2/3.8

6.5/6.5/6.3

6.7/6.7/6.5

8.1/8.1/7.9

11.1/11.0/10.9

16.6/16.6/16.5

4.9/4.8/4.5

5.0/5.0/4.7

6.4/6.3/6.1

8.6/8.6/8.4

12.5/12.5/12.4

3.2/3.0/2.4 c

3.9/3.8/3.4

4.6/4.5/4.2

6.26.1/5.9

9.8/9.7/9.6

2.6/2.4/d

3.3/3.2/2.6

4.0/3.9/3.5

5.6/5.5/5.2

7.7/7.6/7.5

E/F

2.0/1.6/d

2.0/1.7/d

2.1/1.8/d

2.3/2.1/d

2.7/2.5/d

Xinxing Ductile Iron Pipes Technical Manual

103

800

900

1000

1100

1200

1400

1500

104

XINXING PIPES

6.5/6.5/6.3

6.8/6.7/6.6

8.2/8.2/8.0

11.3/11.3/11.2

17.1/17.1/17.0

5.5/5.4/5.2

5.6/5.6/5.4

7.0/6.9/6.8

10.0/10.0/9.9

15.7/15.6/15.6

4.9/4.8/4.5

5.0/4.9/4.7

6.4/6.3/6.1

8.8/8.7/8.6

12.8/12.8/12.7

3.7/3.6/3.3

3.8/3.7/3.4

5.1/5.1/4.9

7.4/7.4/7.3

11.3/11.3/11.2

3.1/2.9/2.3c

3.8/3.7/3.3

4.6/4.5/4.1

6.2/6.1/5.9

9.9/9.9/9.8

1.8/1.5/d

2.6/2.4/1.6c

3.3/3.2/2.8

4.9/4.8/4.6

8.4/8.4/8.3

2.4/2.2/d

3.2/3.0/2.4c

3.9/3.8/3.4

5.5/5.5/5.2

7.7/7.7/7.5

0.9/d/d

1.9/1.6/d

2.7/2.5/1.8c

4.2/4.1/3.8

6.3/6.2/6.0

E/F

1.8/1.2/d

1.8/1.4/d

1.9/1.6/d

2.1/1.8/d

2.5/2.3/d

E/F

d/d/d

d/d/d

d/d/d

d/d/d

d/d/d

6.5/6.5/6.3

6.7/6.7/6.5

8.2/8.1/8.0

11.3/11.2/11.1

17.1/17.0/17.0

5.4/5.4/5.2

5.6/5.5/5.3

7.0/6.9/6.8

10.0/10.0/9.9

15.6/15.6/15.5

4.8/4.7/4.4

5.0/4.9/4.6

6.3/6.3/6.1

8.7/8.6/8.5

12.7/12.7/12.6

3.7/3.6/3.3

3.8/3.7/3.4

5.1/5.1/4.9

7.4/7.4/7.2

11.3/11.3/11.2

3.0/2.9/2.3c

3.7/3.6/3.2

4.5/4.4/4.1

6.1/6.0/5.8

9.8/9.8/9.7

1.8/1.6/d

2.5/2.4/1.7c

3.3/3.2/2.8

4.8/4.8/4.6

8.4/8.4/8.3

2.4/2.2/d

3.1/3.0/2.4 c

3.9/3.8/3.4

5.5/5.4/5.1

7.7/7.6/7.4

0.9/d/d

1.9/1.6/d

2.6/2.5/1.9

4.2/4.1/3.8

6.2/6.2/6.0

E/F

1/7/d/d

1.8/1.3/d

1.8/1.5/d

2.0/1.7/d

2.4/2.2/d

E/F

d/d/d

d/d/d

d/d/d

d/d/d

d/d/d

6.5/6.4/6.2

6.7/6.6/6.4

8.1/8.1/7.9

11.2/11.2/11.0

17.0/17.0/16.9

5.4/5.4/5.2

5.6/5.5/5.4

7.0/6.9/6.8

10.0/10.0/9.9

15.6/15.6/15.5

4.8/4.7/4.4

4.9/4.8/4.5

6.3/6.2/6.0

8.6/8.6/8.4

12.7/12.6/12.5

3.7/3.6/3.3

3.8/3.7/3.4

5.1/5.1/4.9

7.4/7.4/7.2

11.3/11.3/11.2

3.0/2.8/2.1 c

3.7/3.6/3.2

4.4/4.3/4.0

6.0/6.0/5.8

9.8/9.7/9.6

1.8/1.6/d

2.6/2.4/1.8

3.3/3.2/2.8

4.8/4.8/4.6

8.4/8.4/8.3

2.3/2.1/d

3.1/2.9/2.3c

3.8/3.7/3.3

5.4/5.3/5.1

7.6/7.5/7.4

1.0/d/d

1.9/1.7/d

2.6/2.5/2.0

4.2/4.1/3.9

6.2/6.2/6.0

E/F

1.6/d/d

1.7/d/d

1.8/1.4/d

2.0/1.7/d

2.3/2.1/d

E/F

d/d/d

d/d/d

d/d/d

d/d/d

d/d/d

5.5/5.4/5.2

5.7/5.6/5.4

7.1/7.0/6.8

10.1/10.0/9.9

15.7/15.7/15.6

3.7/3.6/3.2

3.9/3.8/3.4

5.2/5.2/4.9

7.5/7.5/7.3

11.4/11.4/11.3

1.8/1.5/d

2.6/2.4/d

3.4/3.2/2.7

4.9/4.8/4.6

8.5/8.5/8.3

d/d/d

1.9/1.6/d

2.7/2.5/d

4.3/4.2/3.8

6.3/6.3/6.1

E/F

d/d/d

d/d/d

d/d/d

d/d/d

d/d/d

5.5/5.4/5.2

5.6/5.6/5.4

7.0/7.0/6.8

10.1/10.0/9.9

15.7/15.7/15.6

3.7/3.6/3.2

3.8/3.7/3.4

5.2/5.1/4.9

7.5/7.4/7.3

11.4/11.3/11.2

1.8/1.5/d

2.6/2.4/d

3.3/3.2/2.7

4.9/4.8/4.6

8.5/8.4/8.3

d/d/d

1.9/1.6/d

2.7/2.5/d

4.2/4.1/3.8

6.3/6.2/6.0

E/F

d/d/d

d/d/d

d/d/d

d/d/d

d/d/d

5.5/5.4/5.2

5.6/5.6/5.4

7.0/7.0/6.8

10.0/10.0/9.9

15.7/15.7/15.6

3.7/3.6/3.2

3.8/3.7/3.4

5.2/5.1/4.9

7.5/7.4/7.3

11.4/11.3/11.2

1.8/1.5/d

2.6/2.4/d

3.3/3.2/2.8

4.9/4.8/4.6

8.5/8.4/8.3

d/d/d

1.9/1.6/d

2.7/2.5/1.7c

4.2/4.1/3.8

6.3/6.2/6.0

E/F

d/d/d

d/d/d

d/d/d

d/d/d

d/d/d

5.4/5.4/5.2

5.6/5.5/5.3

7.0/6.9/6.8

10.0/10.0/9.9

15.7/15.6/15.6

3.7/3.6/3.2

3.8/3.7/3.4

5.2/5.1/4.9

7.5/7.4/7.3

11.3/11.3/11.2

1.8/1.5/d

2.6/2.4/d

3.3/3.2/2.8

4.9/4.8/4.5

8.4/8.4/8.3

d/d/d

1.9/1.6/d

2.6/2.5/1.7c

4.2/4.1/3.8

6.3/6.2/6.0

E/F

d/d/d

d/d/d

d/d/d

d/d/d

d/d/d

Xinxing Ductile Iron Pipes Technical Manual

1600

1800

2000

Notes: a. The traffic load factors applicable to all the burial depths are given as 0.5, 0.75 and 1.5;
b. The allowable burial depth exceeds 50 m;
c. The min burial depth must be more than 1 m;
d. Not recommended.

Xinxing Ductile Iron Pipes Technical Manual

105

4.7 Anchoring methods and design

4.7.1.4 Reducing pipe

When the pipe changes direction (at the elbow or tees), stops (at the end), or changes size (at the tapers),
hydraulic thrust will occur in the water pipeline. On this occasion, the restrictive measures shall be taken

to keep the pipeline from being affected. There are several restrictive methods available, among them, the
concrete anchor blocks and self-anchored joint are the most common methods.

4 .7.1 Thrust force F

thrust force occurring at reducing pipes

The jacking force F is related to maximum field test pressure P of pipeline, sectional area of the pipe or
elbow angle, etc., which can be calculated as follows:

Calculation Formula F=P*(A-a) (N)

4.7.1.1 tees and blank flanges

Where: (A-a) difference of the cross sectional areas on both ends of the reducing pipe
F

Reference Value of Thrust at Fittings With Hydraulic Pressure of 10bar


Thrust F1 (tonf)

tees and
blank
flanges
11.3 bends

DN

DE(mm)

Hydraulic
pressure (bar)

90 bends

45 bends

22.5 bends

80

98

10

1.1

0.6

0.3

0.1

0.8

100

118

10

1.5

0.8

0.4

0.2

1.1

200

222

10

5.5

3.0

1.5

0.8

3.9

Calculation Formula F = P * A (N)

300

326

10

11.8

6.4

3.3

1.6

8.3

Where: P test pressure (generally maximum field test pressure, pa) as prescribed in the acceptance

400

429

10

20.4

11.1

5.6

2.8

14.5

500

532

10

31.4

17.0

8.7

4.4

22.2

600

635

10

44.8

24.2

12.4

6.2

31.7

700

738

10

60.5

32.7

16.7

8.4

42.8

800

842

10

78.7

42.6

21.7

10.9

55.7

900

945

10

99.2

53.7

27.4

13.7

70.1

1000

1048

10

122.0

66.0

33.7

16.9

86.3

1100

1152

10

147.4

79.8

40.7

20.4

104.2

1200

1255

10

174.9

94.7

48.3

24.2

123.7

1400

1462

10

237.4

128.5

65.5

32.9

167.9

1500

1565

10

272.0

147.2

75.1

37.7

192.4

1600

1668

10

309.0

167.2

85.3

42.8

218.5

1800

1875

10

390.5

211.3

107.7

54.1

276.1

2000

2082

10

481.5

260.6

132.8

66.7

340.4

thrust force occurring at tees

thrust force occurring at blank flanges

criteria
A cross sectional area of the branch pipes or blank flange(m2)

4.7.1.2 Bend

4.7.1.3 Tee with angled branch

thrust force occurring at bends


thrust force occurring at angled branch

Calculation Formula F=2*P*A*sin

(N)

Calculation Formula F=P*A*sin (N)

1 The values of thrust F in the above table are calculated on the basis of actual OD of pipes

Where: A cross sectional area of the pipe


Angle of the elbow

106

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

107

4.7.2 Form of concrete anchor blocks

4.7.2.2 anchor block for bends (including bends with various angles)

4.7.2.1 anchor block for tees and blank flanges


settlement point
joint
ground surface

D/2 D/2

H1

200

L/2

H1 D/2 D/2

H
L/2

H5

settlement point joint

L/2

H5

L/2

settlement joint

ground surface

H2

H2

settlement
joint

B
B

Anchor blocks of vertical tees

Horizontal bend anchor blochs

H1

H5

L/2

settlement joint

H2

ground surface

glass wool clothes and straw ropes

H1

L/2

D/2 D/2

H2

settlement joint

B
glass wool clothes and straw ropes

B
200
B

200

500

500

Horizontal bend anchor blochs


Anchor blocks of plug

Note: anchor block horizontal bends mainly applies to pipelines with large-diameter, high testing
pressure

108

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

109

4.7.3 Anchor blocks design

4.7.3.2 anchor blocks of straight up bend

When designing the concrete blocks , full consideration shall be

The vertical component N of resultant external thrusts F on the

taken to provide sufficient resistance so as to bear thrust under

crossing section of the straight up bend and the weight of water

any conditions, including laying conditions and ground conditions,

filling in the pipe are supported by the subsoil at the bottom

size and weight of the blocks , weight of backfilled soil , soil

surface of the blocks, the projective area of the half-packed

reaction against the blocks, as well as friction between pipe and the

blocks is calculated with the following formula:

surrounding soil.
Blocks shall not be built on soft soil. For soft soil, the soil around the
S=

blocks shall be replaced with sand or other applicable material that

N+G1

(m )

can provide adequate soil reaction against the blocks.

[R]-H
Where, N vertical component of F (kN)

The bearing capacity of the ground shall be carefully checked. If it is

G1 total weight of water filled in bends and pipe acting

relatively small, then the foundation area of concrete blocks can be

on the blocks (kN)

expanded, or the groundation should be strengthened.

[R] allowable bearing capacity of foundation (kPa)


concrete gravity density (kN/m2)

4.7.3.1 Design of anchor blocks for Tees, horizontal

H Height of blocks (m)

bends and blank flanges


The resultant force F of the external thrust on the crossing section

4.7.3.3 Anchor blocks of straight down bend

shall be less than sum of the soil reaction against the blocks at

The vertical component N of resultant external thrust F son the

the back of blocks and bottom friction of the blocks, i.e., KFtotal

crossing section of straight down bend shall be less than the

resistance of anchor blocks T:

total weight (G1+G2)of anchor blocks; the horizontal component

T: T=K(T1+T2 ) (N)

Np shall be less than the allowable friction be supported by the


pipe joint:

Where: K safety coefficient, K 1.5

Np=F * sin

T1 soil reaction against the blocks (N)


T2 bottom friction (N)

f(G1+G3-N)+T1

Where: G1total weight of water filled in bends and pipe


acting on the anchor blocks (N)
G3total weight of the anchor blocks (N)
f friction coefficient between the anchor blocks and
soil.
T1passive earth pressure (N)
The straight down bend shall be selected ones with small angle
as possible to reduce weight of the anchor blocks.

110

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

111

4.7.4 Anchoring Length of Self-anchoring System

Anchoring Length of Self-anchoring Pipe (for Reference Only) Unit: m

It is impossible to set the anchored concrete anchor blocks under some special circumstances, such as:
No sufficient space for the specified anchor blocks due to too narrow construction site;
When the pipeline is crossing a river or a bridge;
When the pipeline is crossing a swamp

DN

Dend End

90

45

22.5

11.25

Burial
depth
(m)

1.0

1.5

2.0

1.0

1.5

2.0

1.0

1.5

2.0

1.0

1.5

2.0

1.0

1.5

2.0

80

5.9

3.9

2.8

4.6

3.0

2.2

2.9

1.9

1.4

1.6

1.1

0.8

0.9

0.6

0.5

Therefore, during design and construction of ductile iron pipe, a special pipe fitting or equipment is required

100

7.2

4.8

3.5

5.6

3.7

2.7

3.5

2.3

1.7

2.0

1.3

1.0

1.0

0.7

0.5

to properly connect relevant pipes and fittings together, making the pipeline connection flexible and rigid, so

125

8.8

5.9

4.4

6.9

4.6

3.4

4.3

2.9

2.1

2.4

1.6

1.2

1.3

0.9

0.6

that the joints of pipeline at this section can pass force between each other. The friction generated between

150

10.1

6.9

5.1

8.0

5.4

4.0

4.9

3.3

2.5

2.8

1.9

1.4

1.5

1.0

0.7

200

13.4

9.1

6.9

10.5

7.2

5.4

6.5

4.5

3.4

3.7

2.5

1.9

1.9

1.3

1.0

the pipeline and the surrounding soil can effectively offset the stress generated in the axial and radial

250

16.4

11.4

8.6

12.9

8.9

6.8

8.0

5.5

4.2

4.5

3.1

2.4

2.4

1.6

1.2

directions, thus the anchor blocks can be eleminated.

300

19.4

13.5

10.3

15.2

10.6

8.1

9.5

6.6

5.0

5.3

3.7

2.8

2.8

2.0

1.5

This joint can resist the thrust in places where space is limited or where soil behind the fitting is unable to
provide sufficient support. This restriction method involves the proper locations of these special joints and

400

24.9

17.7

13.6

19.5

13.9

10.7

12.1

8.6

6.6

6.8

4.8

3.7

3.6

2.6

2.0

450

27.7

19.8

15.3

21.7

15.5

12.1

13.5

9.7

7.5

7.6

5.4

4.2

4.0

2.9

2.2

500

30.0

21.6

16.8

23.6

16.9

13.2

14.6

10.5

8.2

8.2

5.9

4.6

4.3

3.1

2.4

fittings, so as to determine number of pipes at each side of the joint in advance.

600

34.6

25.2

19.7

27.2

19.8

15.5

16.9

12.3

9.6

9.5

6.9

5.4

5.0

3.7

2.9

Xinxing can provide the ductile iron pipe with self-anchored joint as follows:

700

38.8

28.6

22.5

30.5

22.4

17.7

18.9

13.9

11.0

10.6

7.8

6.2

5.6

4.1

3.3

1) TF self-anchored joint ductile iron pipe (see Section 1.5 for details)
2) Xanchor self-anchored joint ductile iron pipe (see Section 1.6 for details)
Anchoring length of self-anchored pipe
Restrained length is to calculate how many pipes with self-anchored joints shall be needed along two sides
of the bend, so as to counteract hydraulic thrust force caused by the pressured liquid within the bend with
the frictional force between the pipe and the soil.

800

42.6

31.6

25.1

33.4

24.9

19.7

20.8

15.4

12.2

11.6

8.7

6.9

6.2

4.6

3.6

900

46.2

34.7

27.7

36.3

27.2

21.7

22.5

16.9

13.5

12.6

9.5

7.6

6.7

5.0

4.0

1000

49.6

37.6

30.1

39.0

29.5

23.7

24.2

18.3

14.7

13.6

10.3

8.2

7.2

5.4

4.4

1100

52.8

40.3

32.5

41.5

31.7

25.5

25.8

19.7

15.9

14.4

11.0

8.9

7.7

5.8

4.7

1200

55.7

42.9

34.8

43.7

33.7

27.3

27.2

20.9

17.0

15.2

11.7

9.5

8.1

6.2

5.0

1400

60.7

47.4

38.7

47.7

37.2

30.4

29.6

23.1

18.9

16.6

12.9

10.6

8.8

6.9

5.6

1600

65.8

52.0

42.9

51.7

40.9

33.7

32.1

25.4

21.0

18.0

14.2

11.7

9.5

7.5

6.2

1800

69.0

55.1

45.8

54.2

43.3

36.0

33.7

26.9

22.3

18.9

15.1

12.5

10.0

8.0

6.6

The anchoring length for bead and pipe end are as following:
Note: 1. The following factors shall be considered for the a nchoring length of the self-anchored pipe:

oring

anch

h
lengt

ancho

Laying conditions of the pipeline;

ring le

ngth

anchoring length

Backfilling quality and compactness of backfill;


Physical properties of backfill, such as internal friction angle;
2.The table above applies to the buried pipeline being coated with ordinary metallic zinc coating or metallic zinc and general

Terminal

finishing layer in the ordinary soil with an internal friction angle of 30 , test pressure of 10Bar, and safety factor of 1.2.
3 When the DI pipe has PE sleeve or its external coating is polyurethane, the data in the table can be multiplied by 1.9; if
more accurate data are needed, please contact us.
4. If data in the table is divided by 10 and then multiplied by the pressure value (unit: bar) you need, the result can be
obtained for the pressure required;

112

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

113

Chapter V
Construction,
Installation and
Acceptance of
Ductile Iron Pipe

114

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

115

5.1 Trench excavation 118


5.1.1 Trench excavation shall comply with the following requirements
5.1.2 Trench width
5 .1.3 Foundation treatment
5.2 Pipe installation 120

Chapter V
Construction,
Installation and
Acceptance of
Ductile Iron Pipe

5.2.1 Preparation
5.2.2 Installation of ductile iron pipe with T-type joint
5.2.3 Connection of XT2-type Joint ductile iron pipe
5.2.4 Connection of ductile iron pipe with TF self-anchored joint
5.2.5 Connection of ductile iron pipe with Xanchor self-anchored joint
5.2.6 Installation of PE protective sleeve
5.2.7 Construction of XTJ jacking pipe
5.2.8 Construction under special conditions
5.3 Trench backfill143
5.4 Site Repairing of coating 144
5.5 Methods of circle calibration 144
5.6 Pipe cutting 145
5.7 Welding of self-anchored joint bead 146
5.8 Repairing the damaged pipeline 148
5.9 Pressure test and acceptance150
5.9.1 Provisions on pressure test
5.9.2 Water injection
5.9.3 Pressure test procedure
5.9.4 Eligibility criteria

116

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

117

5.1 Trench excavation

Table 1 Reference Width of Pipe Trench

5.1.1 Trench excavation shall comply with the following requirements:

unit: mm

Nominal diameter DN

Trench width W

Nominal diameter DN

Trench width W

80

680

700

1300

(1) The excavated section of the trench shall meet the design requirements; the original subsoil at the

100

700

800

1400

trench bottom cant be disturbed. For mechanical excavation, 200 ~ 300mm soil layer shall be reserved at

150

750

900

1500

200

800

1000

1600

250

850

1100

1700

the trench bottom which will be excavated manually to the designed elevation and then leveled off;
(2)The trench bottom shall not be subject to water immersion or freezing, otherwise, it is necessary to use

300

900

1200

1800

sand gravel or limestone soil to backfill;

350

950

1400

2000

(3) When the soil layer at the trench bottom is miscellaneous fill or corrosive soil, they shall be excavated
completely and then the foundation shall be treated according to the design requirements;
(4) Joint holes shall be reserved at each joint for the socket of the pipe, so as to ensure straightness of the
pipe and meet the requirement of installation.

400

1000

1500

2100

450

1050

1600

2200

500

1100

1800

2400

600

1200

2000

2600

Notes: (1) The W in above table refers to the clear width of a pipeline trench.

(5) For those influenced on the groundwater, the dewatering and drainage program for construction shall be

(2) If wood supports, baffles, braces and auxiliary means are used, the trench shall be widened to facilitate

developed according to the design requirements .

the placement of them.

5 .1.3 Foundation treatment


(1) The pipeline foundation shall meet the design requirements. When strength of the natural foundation
of pipeline fails to meet the design requirements, it shall be reinforced in accordance with the design
requirements.
(2) When part of the original soil foundation is over-excavated or disturbed at the trench bottom, it shall be
treated in accordance with the following requirements:
When the over-excavation depth is no more than 150mm, it can be backfilled and compacted with the
original soil, which compactness shall not be less than that of the original foundation soil;
When the foundation soil at the trench bottom contains large amount of water and is not suitable to

5.1.2 Trench width


The trench shall be excavated in accordance with the design requirements. If no design requirements are
available, trench patterns can refer to Figure 1 and Figure 2, and the width W of the trench bottom can
refer to Table 1.

compact, some effective measures shall be taken, such as replacement.


When the foundation soil is disturbed due to impeded drainage, it can be treated as the following
methods:
When the disturbance depth is within 100mm, the naturally graded sandstone or gravel shall be used to
backfill;
When the disturbance depth is within 300mm and the lower part is hard, it is suitable to use the pebbles
or rubbles to backfill, then use the gravel to fill the gaps and level up the surface;
(3) When the original foundation is composed of rock or hard soil, a sand bed of 150 ~ 200mm in thickness

shoring

without shoring

Figure 1 Pipe trench in poor soil


118

XINXING PIPES

shall be paved beneath the pipeline;

Figure 2 Pipe trench in good soil


Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

119

(4) Cleaning the joint parts for the pipe spigot and socket
Clean the joint parts of the pipe spigot and socket before the pipe laying, especially for location to place
gasket, where dust, sand, stones and other substances are not allowed.

5.2 Pipe installation

(5) Pipe plug


When the pipes are not in laying, measures shall be taken to seal the pipe ends under installation, so as to

5.2.1 Preparation

avoid sewage or sand in the trench from entering the pipes.

(1) Pipe laying


Prepare all tools, instruments and equipment ready as required before installation. All pipes, fittings, valves
and fire hydrants are arranged along both sides of the trench. Dont place at the side with piles of soil as
possible.

5.2.2 Installation of ductile iron pipe with T-type joint


(1) Installation of sealing ring

Put the gasket into the groove of the socket .


For the gasket with smaller size ( DN800), it shall be bent into the shape as shown in Fig. 3 and then
put into the sealing groove of the socket ;
For the gasket with larger size (> DN800), it shall be bent into the shape as shown in Fig. 4 and then
put into the sealing groove of the socket;

When the gasket is put into the socket, impose radial force to keep it fully into the groove of socket, as
shown in Figure 5;

(2) Putting pipes into the trench


Carefully put the pipe into the trench with the help of the crane, rope or other suitable tools or equipment.
Its forbidden to directly throw or dump the pipe in the trench.
The lifting shall be conducted in accordance with the requirements in Section 3.1 lifting of ductile iron
pipes.
(3) Inspection
Carefully check whether there is damage and other defects on the pipes before installation.
120

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Figure 3 DNDN800

Xinxing Ductile Iron Pipes Technical Manual

Figure 4 DN

DN800

121

(2)Joint connection
While connecting, firstly align the socket and the spigot of two pipes, then slowly push the
spigot into the socket, and insert it between the two spigot lines, as shown in the Figure7.
Stop the installation immediately if too much resistance is found during inserting the ductile
iron pipe. Pull out the pipe and check location of the gasket, the socket and the spigot of the
pipe, identify the causes and handle them properly before re-installation.
Note: Mark the spigot line clearly before installation while installing the sawed ductile iron
pipe.

Figure 5

Lubricate the working surfaces of gasket and the


spigot of another pipe, as shown in Figure 6

Figure 7 Insert Depth of the Spigot

Different tools can be used to install in view of specifications of ductile iron pipes:
Simple tools, like crowbar can be used for the pipes below DN150. Hardwood must be
used to protect between the crowbar and the socket surface (see Fig. 8);
Tools like steel cable and guide chain can be used for installation of pipes above
DN200 (the contact between the steel cable or guide chain and pipes shall be protected by
a flexible materials , so as to avoid damage to the pipe body and both internal and external

Labricating
paste

coatings) (see Fig. 9). Please refer to Table 2 for the tonnage and quantity of guide chains for

Figure 6 Applicatio of Lubricant

installing ductile iron pipes of different specifications; an excavator can also be used for such
installation (Fig. 10), position between the pipe and bucket must be protected by hardwood ;

Figure 8 Installation of pipes of DN80~DN150

122

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

Figure 9 Installation of pipes of DN200-DN2000

123

Table 2 Guide Chain Parameter for T-type Joint Pipe Installation


DN

Guide chain parameters (tonnage)

Table 3 Insertion Depth of Spigot end for T-type Joint Ductile Iron Pipes (Recommended)
P-10

Chain guide (PCS)

DN100~200

DN300~400

DN500~600

DN700~800

DN900~1000

DN1200~1400

2~3

DN1600~2000

10

2~3

Wooden block or block of other material

Size

T-type
Joint

DN80

P-10

XT2-type
Joit

Size

T-type
Joint

75

82

DN450

DN100

78

84

DN125

80

DN150

85

DN200

90

DN250

95

DN300

100

DN350
DN400

P-10

XT2-type
Joint

Size

T-type
Joint

XT2-type
Joint

110

105

DN1400

230

235

DN500

110

107

DN1500

240

DN600

110

112

DN1600

250

255

90

DN700

140

137

DN1800

290

265

DN800

150

DN2000

309

280

DN900

165

DN2200

307

97

DN1000

175

DN2400

326

100

100

DN1100

190

DN2600

343

100

102

DN1200

205

157

95

147

5.2.3 Connection of XT2-type Joint ductile iron pipe


The connection method sees 5.2.2 Installation of ductile iron pipe with T-joint and the insertion depth of the
spigot sees Table 3.
Figure 10 installation with an excavator

5.2.4 Connection of ductile iron pipe with TF self-anchored joint

(3)Installation check
Upon the completion of connection, the method shown in Figure 11 can be used to check the position of the

gasket :
Use a thin and narrow steel ruler to check the compression ratio of gasket at the four points around the
spigot with an angle of 90 between them. The steel ruler shall be inserted with the almost same depths at
four points, which can indicate a normal connection of joint.
The insertion depth at the spigot generally equals to the depth P of socket minus 10mm (see Table 3 for the
dimensions of the spigot insertion). In real installation, the first spigot line of one pipe shall all be covered by
the socket end of its adjoining pipe, and the second spigot line shall be exposed.

Think narrow ruler

Figure 12

NO.

name

gland

Locking
Ring

Welded
Bead

spigot

Bolts with
hooked
head

gasket

Socket

Figure 11 Inspecting installation position of gasket

124

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

125

(1)Inspection and cleaning before installation


Clean the working surface of socket with brush. Carefully check whether there is
defect on the inner surface of the socket, especially the sealed working surface which
may affect the sealing;
Check whether there is defect on the gasket, gland, and locking ring for connection;
Check whether the chamfer of self-anchored spigot and welded bead at the spigot
can meet the installation requirements.

Figure 13 Installation diagram of gland and welded bead

(2)Installation Steps
First, push gland 1 and locking ring 2 successively from the spigot 4 and pass
them through thrust welded bead 3, as shown in the figure 17. When the locking ring
completely crosses the welded bead, push it back so that the locking ring can fit with
the end face of the welded bead;
Insert spigot 4 into socket 7 of another pipe with gasket 6 installed (Please refer to
5.2.2 Installation of ductile iron pipe with T-joint for the specific connection).
Move the gland to the locking ring. Adjust the gap between gland 1 and the pipe
body to make it substantially evenly well-distributed, keep the end faces of gland 1
and socket 7 in parallel, make the internal conical surface of gland 1 to closely fit the
external conical surface of locking ring 2, then tighten hook bolt 5 to fix gland 1 with
socket 7 by tightening hook bolt 5. When tightening the bolt, take care to it is necessary
to carefully check and adjust so that the bevel eave tile slope of hook bolt 5 fits well
with the boss of the socket, and so that the gap between gland 1 and the face of the
socket end can be even almost even

126

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

127

5.2.5 Connection of ductile iron pipe with


Xanchor self-anchored joint

Step 2: align two beveled adges of the front stoppers with

Install gasket

press the front stoppers between two rear stoppers, see Fig.

Installed gasket is as shown in Figure 14. Its installation is

17;

the same as that of T-joint. Please refer to 5.2.2 Installation

Note: Be sure to press them completely in place

the corresponding beveled adges of two rear stoppers; then

of ductile iron pipe with T-joint for details;

Figure 17 Installation of front stopper

Figure 14 Installation of Sealing Ring

Installation of the support ring

Step 3: alternately install the rear and front stoppers. When

Put the support ring in the position of the socket as shown in

installing the last front stopper, a crowbar may be required to

Fig. 15;

press it between two rear stoppers due to the squeezing of


stoppers, see Fig. 18;

Figure 15 Installation of the support ring

Figure 18 Finish Installation of Stoppers

Installation of the stopper

Connection of socket and spigot

Step 1: install two rear stoppers onto two adjacent bulges in

The installation is the same as that of XT2-joint pipe. See

the support ring, and insert the groove of stopper onto the

5.2.3 Installation of ductile iron pipe with XT2-joint for

bulge in the support ring, see Fig. 16;

details;

Figure 16 Installation of rear stopper

128

XINXING PIPES

Figure 19 Finish Connection of Xanchor Joint


Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

129

5.2.6 Installation of PE protective sleeve

Note: if this method is applied to the DIP connected with bolted, a layer of PE protective
sleeve must be added at the pipe joints;

PE sleeve method refers to a kind of anti-corrosion method for the metal pipe free from corrosion within
the service period by using a complete PE pipe or sheet to wrap up the buried pipeline before the pipeline

Installation sequence (take Method A for instance only)

installation, so as to separate the metal pipes from their corrosive soil environment.

Step 1: use steel cable or sling to lift the pipe almost at the middle of the pipe and keep

There have been over 50 years to use PE sleeve to protect ductile iron pipe against corrosion. It have

the entire pipe off the ground; cover the already-cut polyethylene sleeve (1m longer than

been proved by extensive laboratory research and practical engineering cases that this method is still the

the pipe) on the pipe between the spigot and steel cable from the end of pipe spigot;

most cost-effective method for anti-corrosion, suitable for buried ductile iron pipelines in most corrosive
environments .
Note: The harshly corrosive environments with high-density stray currents and those specified in Annex A of
AWWA C105 are exception.
Performance requirement of PE protective sleeve
The material and performance of PE protective sleeve shall meet the requirements of ISO8180 or AWWA
C105
Features of PE protective sleeve
A. Easy to construct, and highly cost-effective anti-corrosion;

Step 2: lower the pipe into the trench and connect the pipe which has been installed before.

B. Suitable for most corrosive environments;


C. Free maintenance during use;
D. except for the material properties, its protective effect mainly depend on the installation quality.
Installation method
Method A: Covering Method (see the figure below)
Cover a long PE sleeves outside the ductile iron pipes and overlap at the joint of the pipes

Step3:slip the steel cable, lift the socket of the pipe, then spread the PE cover over
the entire barrel of the pipe;

Method B. Wrapping Method (see the figure below)


Wrap whole pipe with a wide PE sheet

130

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

131

Step 4: pull back the surplus polyethylene sleeve at the side of the joint socket, wrap

Step 7: secure the fold of the PE sleeve along the axial direction of the pipe barrel

it onto the pipes at the joint and use the adhesive tape to secure it in place;

with adhesive tape at every 1m.

Step 8: repair all small rips, tears or other tube damage with adhesive tape or PE
tape;
Step 5: straighten the surplus PE sleeve at the end of the spigot, spread it and wrap
it on the joint. Then bunch the end of the PE pipe onto the ductile iron pipe;

Step 9: carefully backfill the pipe according to AWWA C600 for backfill procedure.
Slowly backfill to prevent damage to the PE sleeve during backfilling;

Dimensions of PE protective sleeve


Table 4 Width of PE Protective Sleeve for Ductile Iron Pipe (mm)
Step 6: take up slack in the PE sleeve along the barrel of the pipe to make a snug,
but not tight, fit. Fold excess polyethylene back over the top of the pipe;

132

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Nominal diameter
DN

100

200

300

500

800

1000

1200

1500

1800

2000

Folded width of PE
tube

580

950

1300

2000

3050

3720

4400

5470

6550

7200

Xinxing Ductile Iron Pipes Technical Manual

133

In order to prevent large hard objects from damaging PE sleeve during backfilling, the grassy meadow
can be put on top of the pipe or sand, loam or soil without stones and other hard objects can be used for
backfilling. It is preferential to forbid from walking on the completed pipes, so as to avoid damage to the PE
sleeve.
For fittings such as tees and crosses, as required by the pipe shapes, it is necessary to cut off the PE
sleeve or directly wrap PE sheet arround the entire pipe and then stick the joints of PE sleeve with the
adhesive tape.

5.2.7 Construction of XTJ jacking pipe


Pipe jacking construction is to utilize the jacking force generated from the jacking equipment in the working
pit to overcome friction between pipe and the surrounding soil and jack the pipe section by section into the
soil as required in the design, then remove the earth till the pipes are laid completely, as shown in the figure
below.

Construction of XTJ jacking pipe

5.2.7.1 Construction investigation


Category and burial depth of soil layer
Physical and mechanical properties of soil mass and soil layer
Groundwater level and pressure
Corrosivity of groundwater and soil
Distribution of underground pipelines and structures, etc.
Dead loads on the ground, such as buildings, and dynamic loads on the ground, etc.

134

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

135

5.2.7.2 Selection of pipe-jacking methods and push bench


The pipe-jacking methods shall be selected on the basis of nature of the soil layer, pipe diameter,

back wall

Main jacking Average


cylinder
pressing ring

XTJ Jacking pipe


or tooling pipe

Rubber sealing gate

groundwater level, ground and underground buildings structures and facilities nearby, and so on, and
determined after the technical and economic comparison is conducted. In case no relevant experience is
available, Table 5 can be referred to.
Table 5 Reference for Selection of Push Bench
Open push bench
Stratum
Mechanical
Cemented soil, strong
weathered rock

Stable soil

Loose soil

no
groundwater

Extrusion

Balance push bench

Manual
excavation

Earth
pressure
balance

Slurry
balance

Pressure
balance

Figure 20 Working Well Design

Determining min length of the working well

Sludge fd 30kpa

water content in clayey soil > 30%

water content in silty soil <30%

Stratum below

Silty soil

a thickness of back wall, generally preferable to 0.6 m

groundwater

Sandy soil k 10-4 cm/s

b length of jack (m), generally preferable to 2.5 m

Sandy soil k 10-4~10-3 cm/s

Gravel sand k 10-3~10-2 cm/s

Including obstacles

Minimum internal length of the working well can be calculated with the following formula
La+b+c+d+d+e
Where, Lmin net internal length of the working well (m)

c thickness of the average pressing ring, generally preferable to 0.2 (m);


dthe length of push bench or pipe,Choose a larger value; (m).
esealing width and installation surplus(m)

Determining min width of the working well


Minimum width of the rectangular working well shall meet the following formula:

5.2.7.3 Installation preparation before construction

B=D+(2.0~4.0)

Design requirements of working well and receiving well

Where, Bnet internal width of the working well (m);

(1)General regulations

Dmaximum external diameter of the pipe (m)

a.To facilitate drainage, excavation and transportation, the working well and receiving well shall be located

(3) Sizes of the receiving well

close to the power and water, far away from the residential areas and high-voltage lines, and avoiding

Min net internal width of receiving well shall not be more than min net width of the working well; min net

adverse impact on the surrounding buildings, structures and facilities as possible;

internal length of the receiving well shall be sufficient for removal of the push bench in the well and hoisting

b.The working well and receiving well can be structured with steel sheet pile, open caisson, underground

out of the well as well as connecting the process pipeline.

diaphragm walls or poured piles;

Strength of back wall

c.The working well and receiving well can be constructed in the circular, rectangular or polygonal form. The

Basic requirements

pipeline-crossing intermediate well and large-depth working well can be circular or polygonal.

Sufficient strength

(2)Design of the working well

Sufficient rigidity
Flat surface of back wall

136

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

137

Homogeneous material

Table 6 Coefficient of Active and Passive Earth Pressures of Soil

Simple structure, easy to assembly and disassembly


Soil category

internal friction angle


of soil ()

Coefficient of passive
earth pressure KP

Coefficient of active
earth pressure KA

Assumed that the jacking of the main jack is evenly imposed on the soil mass behind the working pit through

Soft soil

10

1.42

0.70

2.03

the back wall, the reaction force R of the back wall shall be 1.2 ~ 1.6 times of total jacking force F0, so as

Clay

20

2.04

0.49

4.16

to ensure the safety of the back wall during jacking, the reaction force R can be calculated with the following

Sand clay

25

2.46

0.41

6.00

Silty soil

27

2.66

0.38

7.00

Sandy soil

30

3.00

0.33

9.09

Gravel soil

35

3.69

0.27

13.67

Calculation formula of reaction force of back wall

formula:
2

R =aB H

KP
2

+2cH

KP+hHKP

Where: R reaction force of the total thrust(kN)

KP
KA

5.2.7.4 Main auxiliary equipment for construction

coefficient, range from 1.5 to 2.5

Hoisting machinery

B width of the back wall (m)

Pipe jacking requires equipment for vertical hoisting and transportation. Overhead crane (i.e. portal crane)

bulk weight of soil (kN/m3)

or rotating jib crane (such as truck crane, crawler cranes) can be used under common circumstances, and

H height of back wall (m)

their hoisting capacity must meet the following working requirements:

Kp coefficient of passive earth pressure (see the table below);

Mounting and dismounting of pipe-jacking heading machine and jacking equipment;

C cohesion of soil (kPa)

Hoisting of the jacking pipeline, mounting and dismounting of top rail;

h height of soil mass from the ground to top of back wall (m)

Vertical transportation of earthwork and materials


Installation of earthwork transportation equipment
There are two kinds of earthwork transportation: transportation within the pipe and the field. For
transportation within the pipe, the nature of soil shall be considered to select type of heading machine,
space of in-pipe work, earth amount for each jacking, jacking length and so on.
Ventilation system
For long distance pipeline, it is usually necessary for worker to operate inside the constructed pipeline
during construction. If the workers stay inside for a long time, it is easy to cause accidents due to anoxia of
human body. Therefore, an air compressor shall be equipped to ventilate the working well and the pipeline,
so as to ensure safety of workers during pipe jacking.

5.2.7.5 Calculation of jacking force


1) Jacking force
The total jacking force of the pipeline can be estimated with the following formula
F0=D1Lfk+NF
Where, F0 standard value of total jacking force (kN)
D1 pipe external diameter (mm)
L designed jacking length of pipeline (m)
fk average friction between the external pipe wall and soil (kN/m2)
NF head resistance of push bench, which can be calculated on basis of Table 8 for different

138

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

push bench with different nozzles, (kN).

Xinxing Ductile Iron Pipes Technical Manual

139

Table 7 Calculation Formula for Head Resistance of the Push Bench (NF)
End face of push
bench

Common machine type Calculation formula of head resistance

Symbol in the formula

Cutting edge

Mechanical
Manual excavating

NF=(Dg-t)tR

t-blade thickness (m)

Socket mouth

Push-in

NF=Dg (1-e)R/4

e-opening rate

Grid

Push-in

NF=Dg aR/4

Grid plus air pressure

Air pressure balance

NF=Dg (aR+Pn)/4

Large cutter cutting

Earth pressure balance


Slurry balance

NF=Dg HF/4

a-grid-sectional parameters
Preferably a = 0.6~1.0

Pnair pressure(kN/m2)

Take measures to reduce land subsidence


For unstablized soil, it is applicable to selecte a push bench with balance function,instead of open
excavating push bench. A ground observation point can be established, and the balance parameters can be
determined for the push bench with the balance function through trial jacking.

5.2.8 Construction under special conditions


5.2.8.1 Laying pipes on slopes
The risks of landslide may exist when laying pipes under the following slopes:

specific gravity of soil(kN/m3)

Laying pipes on the ground with slope over 20%;

HFoverburden thickness(m)

Laying pipes under the ground with slope over 25%;


This risk can be eliminated through setting up a concrete block at the back of the socket (in this case, the

Note: Dg external diameter of push bench (m)

socket shall be located upward), as shown in Figure 25.

R extrusion resistance (kN/m2), preferably R = 300 ~ 500kN/m2.

clamps

5.2.7.6 Excavating and jacking


Excavating and jacking can be started when equipment in the working pit has been installed and kept in

unrestrained joint

good conditions during inspection.


Firstly, lower the pipe to the guide rail and put it in place, install the thrust ring, then check elevations of the
pipe center and bottom. If they meet the design requirements, pipe jacking can be started.
Precautions for jacking:
General principles

Figure 21 Laying pipes on slope

a. Continuously operate with the principle of jacking following excavating, jacking while excavating
followed, any suspension shall be avoided , otherwise it will increase the resistance and jacking difficulty;

5.2.8.2 Laying pipes on level ground

b. The quality of whole jacking pipeline is related to the jacking direction and elevation of the first section of

For the spigot and socket pipes laid on the ground, its suggested to provide one support for each pipe,

pipe. So it is necessary to frequently measure and check to timely correct the deviation, if any;

such as concrete stand. The support shall be put behind the socket of each pipe.

c. If the stroke of jacking cylinder is less than the length of a single pipe, then the piston can be withdrawn

Fix the pipe onto the support with steel strip. Insert a rubber pad to increase friction between the steel

after the cylinder piston is stretched out for one working stroke, now a thrust ring can be added between the

strip and pipe. Thus, the axial stretch of the pipe resulting from temperature change can be absorbed at

piston and jacking pipe, the jacking can proceed continuously;

each joint.

d. Once the earthwork in front of the pipe collapses or the pressure gauge hand of the pump suddenly

For detailed operations, please refer to Figure 22 and 23.

swings substantially during jacking, the jacking shall be stopped immediately and proceed until the causes

The fittings that are likely to produce thrust due to the internal pressure, such as the elbows and Tees, shall

are identified and the faults are removed.

be protected by the anchorage.

e. The maximum working jacking force of the jacking cylinder shall not exceed the allowable jacking thrust.

Fixing clamp

The relevant measures can be taken to reduce the jacking resistance


The grouting is the most effective way to reduce the jacking resistance during jacking of long distance pipe,

rubber lining

namely, injecting slurry around the pipe wall to form a lubricating sleeve so as to reduce resistance when
jacking.
Figure 22 Fixing clip put behind the socket

140

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

141

clamps

5.3 Trench backfill

joints

(1) Backfill the trench in time when the pipeline construction is completed and passed inspection.
For pressure pipes, both sides and top of pipe, except for the joints, shall be backfilled for no less
than0.5m high before the water pressure test; The rest parts shall be timely backfilled when it is qualified
Figure 23 Pipe laying on level ground

during the water pressure test.


Non-pressure pipes shall be timely backfilled when it is qualified during the water pressure test.

5.2.8. 3 Installation through ditches

(2) The following requirements shall be met during backfill of the trench:

There are three main installation methods for pipes going through the ditches,

Clean up brick, stone, wood blocks and other debris in the trench;

attaching the existing bridge, as shown in Fig. 24a;

No water shall exist in the trench, and dont backfill with water;

build a special bridge for the pipeline, as shown in Fig. 24b;

(3)The following requirements shall be complied during trench backfilling:

Hanging under a bridge, as shown in Fig. 24c

Check whether there is any damage or deformation on the pipe before backfilling. If any, it shall be
repaired or replaced;
The range of the effective support angle at the pipe base shall be filled and compacted by granular sand,
keeping it contact closely with the pipe wall;

(a)

Simultaneously backfill and compact from both sides of pipeline; take measures against pipeline floating
and displacement when backfilling below the centre of pipe;
Manual tamp shall be conducted from the base of pipe bottom to the level of 500mm above the pipe
top during the trench backfilling; The locations beyond 500mm above the pipe top shall be compacted with

machine from both sides of the pipe;


(4)The requirements below shall be met during backfilling:
No organic, frozen soil, or other hard objects over 50mm, such as brick and stone can exist from the
trench bottom to level of 500mm above the pipe top;

(b)

When backfilling in the freezing period, frozen soil can be evenly mixed at the range over 500mm above
the pipe top, but its amount can not go beyond 15% of the total volume of the filling;
(5)The loose laying depth of each layer of backfill shall be selected on the basis of the compacting appliance
adopted as specified in Table 8.

L
Table 8 Loose Laying Depth of Every Layer of Backfill

43

(c)

Typical surport

Compacting appliance

Loose laying depth(mm)

Wooden rammer, iron rammer

200

Light compacting appliance

200~250

Roller

200~300

Vibratory roller

400

Figure 24 Typical installation forms of pipelines crossing rivers

142

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

143

When the pipe is laid under the roadway, the road shall be paved immediately after the laying; when the
pipe is located in the soft soil layer and low-lying, swamp, or high groundwater level sections, the medium

5.6 Pipe cutting

and coarse sand shall be firstly used to backfill and compact the auxiliary corners of pipe base, and then

1) When the spigot of DIP is damaged due to improper handling, affecting installation, this part shall be cut

medium and coarse sand shall be used to backfill layer by layer till 500mm above the pipe top.

off;

When the ductile iron pipe is backfilled to the design elevation, the deformation rate of the pipe shall be

2) In event that the pipe length shall be determined in the field for the sake of installing pipe fittings during

measured and recorded within 12 ~ 24h, which shall meet the design requirements; if there is no design

construction, the pipe shall also be cut off.

requirements available, such deformation rate shall not exceed 2%.

For the DIP with a diameter DN300, cutting can be conducted at 2/3 of the pipe barrel starting from the

The covering depth above the pipe top shall meet the design requirements; please refer to Appendix B of

spigot end face;

this specification if no design requirement is available;

For the DIP with a diameter > DN300, the manufacturers generally provide cuttable pipes with a certain
percentage.
3) Pipe-cutting tools: abrasive cutter or electric metal-saw pipe cutter can be adopted. The method of

5.4 Site Repairing of coating

oxygen cutting is forbidden, since over-high cutting temperature will affect performance of ductile iron
material.

Any damage on the internal and external coatings during hoisting, transportation and installation must be

4) For T-joint and XT2-joint DIP, the newly-cut end shall be rounded and chamfered so as to avoid the

repaired. Refer to 1.11 Coating Repairment for detailed methods of site repair.

damage to the gasket while installing.

5.5 Methods of circle calibration


Ovality may be caused for pipe spigot during transportation

and handling. For the pipes below DN400, the part with oval
deformation shall be cut off, while for the pipes above DN500,

Y
Surport
Figure 26 toothless abrasive cutter

the circle-calibrating appliance shall be used (as shown in


Figure 25). The attentions shall be paid during calibration:

Jack

Table 9 Dimension of the Spigot Chamfer

(1) The size and shape of block arc at the lower and upper arc
of the jack shall be made respectively in accordance with the
different specifications of pipes to be calibrated.
(2) Reference data for jacking amount of circle calibration: the

Figure 25 deveices for circle-calibrating

excess jacking is needed during circle calibration, if the nominal


diameter of pipe is 100mm, it shall be jacked to 105mm while
calibrating, the excess jacking value is related to such factors
as the size, thickness and elliptical extent of the pipe, and the

144

Figure 27 spigot chamfer

DN(mm)

DE(mm)

X(mm)

Y(mm)

DN(mm)

DE(mm)

X(mm)

Y(mm)

80

98

600

635

100

118

700

738

15

125

144

800

842

15

150

170

900

945

15

200

222

1000

1048

15

250

274

1100

1152

15

actual accurate amount can be determined through test while

300

326

1200

1255

15

calibrating in the field;

350

378

1400

1462

20

(3) Once the cement lining is fractured or crushed while

400

429

1500

1565

21

calibrating, the cement lining shall be repaired as required.

450

480

1600

1668

21

500

532

1800

1875

27

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

145

5.7 Welding of self-anchored joint bead

Table 10 Dimensions of the Welded Bead for TF Self-anchored Joint

Under guidance of the professional welding engineer, the ductile iron pipe can be welded in the field.

DN

PFA(bar)

Welded bead parameters(mm)


a

DN

PFA1(bar)

Welded bead parameters(mm)


a

116

4.5

116

4.5

148

158

Welding shall be done under certain environment conditions.

DN80

82

DN500

Welding tools

DN100

85

DN600

Main welding tools cover welder, grinder, nickel-based electrode and copperplate positioning device, etc.;

DN150

89

DN700

Welding procedure

DN200

95

Firstly, carefully clean the outer surface of DIP with abrasion wheel, as shown in Fig. 28. The polishing

DN250

105

shall not affect the wall thickness;

DN300

Fix the copper plate positioning device onto the external wall of DIP according to the sizes shown in

DN350

Table11. The copper guide ring must be close to the pipe wall. If necessary, tap it with a hammer, as shown

DN400

in Fig. 29;

1 The table above shows parameters of welded bead for TF-seif-anchored joint DIP of K9 class. If the designed
pressure is higher than the PFA value in the table above, the welded bead parameters and wall thickness of pipe shall also
be increased correspondingly. Please contact us for the specific parameters.

Layered when welding to ensure the welding quality, as shown in Fig. 30;

30

25

25

DN800
DN900

23

173

105

DN1000

22

183

105

DN1100

21

198

105

DN1200

20

213

Remove the copper guide ring, polish the weld ring to the dimensions shown in Figure 33 and Table11.
Coating repair
ductile iron pipe Copper guide

welded bead

Clean up the welding area. The cleaned surface is required to be smooth and clean, oil- and dust-free.
Please refer to Section 1.11 Coating Repairment for the detailed repair methods of the internal and
external coatings.

Figure 28 Surface cleaning

Figure 29 welding ring overlaying

a
c

Figure 30 Dimensions of the Welded Bead for TF Self-anchored Joint

146

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

147

5.8 Repairing the damaged pipeline

(4)Pipe replacement
As shown in Fig33. cut a section of same-size double-spigot short pipe with a length of(L-8) and put it at the

If the ductile iron pipe being used is damaged locally and leaks, it can be repaired with K-type collar repair

position for replacement;

solution. Detailed operation is as following:

(5)Connection of collar

(1) Excavation and pipe breaking

Move axially two K-type collars to the newly-inserted pipe section and connect them according to the

Dig out the damaged part of the pipeline, cut off the damaged pipe section after confirming the damaged

requirements in 4.2.4 Installation of ductile iron pipe with K-joint. The completed connection is shown in

part length,, as shown in Figure31;

the figure 34;

breakage

Figure 34 K-Type Collar Repair


Figure 31 Pipe cutting

(2)Preparation of pipe replacement

(6)Coating repair

Prepare a section of double-spigot pipe of the same specification and two sets of K-type collar assembly;

Repair the coating damaged during cuttings according to the coating-repair requirements provided by the

(3)Install K-type collar

manufacturer before installing all the parts. Please refer to 1.11 Coating Repairment for detailed repair

Connect two connection ends of K-type collar to two ends of pipe to be repaired, so that the spigot of

methods;

original pipe can be inserted into max installation depth of K-type collar, see Fig. 32 for details;
K-type collar

Figure 32 Installation of K-type collar

K-type collar

L
double-spigot short pipe

Original pipeline

Figure 33 Installation details of K-type collar

148

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

149

5.9 Pressure test and acceptance

keep the test pressure by a pump at least: one hour for DN 600; three hours for 600 <DN1400; and
six hours for DN> 1400. Meanwhile the water amount for maintaining the pressure shall be measured.

A newly-installed water supply and drainage pipeline shall undergo hydrostatic pressure test before being
put into usage. The test pressure and acceptance criteria can refer to ISO10802.

5.9.4 Eligibility criteria


Pressure pipeline: water loss shall not exceed 0.001 l/hr/km (pipeline length)/mm (nominal size)/bar (static

5.9.1 Provisions on pressure test

pressure, average hydraulic pressure exerted on the test area, if elevations of every location on the entire

Length of pressure test section

pipeline are quite different, then the loss criteria shall be calculated on the basis of the weighted average

Unless otherwise stated for pressure pipelines, length of pressure test section shall not be beyond 1,000 ~

pressures). The pressure test is regarded passed when water loss from DN100 pipeline per kilometer under

1,500m.

pressure test of 10 bar is not more than 1 l/h.

Test pressure

Non-pressure pipelines: water loss shall not exceed 0.1 l/km (pipeline length)/mm (nominal size). However,

1)The test pressure at the lowest point of test area shall not be less than the limit values specified in a) or b)

when the prescribed test pressure exceeds 1 bar, the eligibility criteria of pressure pipeline will be applicable.

(whichever is larger).
a) When the working pressure is less than or equal to 10 bar: test value is 1.5 times of the working pressure;
when the working pressure is greater than 10 bar: test value is the working pressure plus 5 bar.
b) Maximum working pressure
2)The test pressure at the highest point of test area shall not be less than the working pressure at the same
point.
3) The test pressure shall not exceed:
a) Max test pressure applicable to pipes, pipe fittings, flanges and accessories specified in the standard;
b) Design pressure of clamp or anchor device.

5.9.2 Water injection


In general, when water is injected at the lowest point of test pipe section, th water flow shall be
sufficient to ensure that all air can be eliminated; Air exhauster shall be furnished at all higher points of
pipeline.
It is recommended that injected water flow shall not exceed 10% over design operation flow.
Cement-lined pipe shall keep water for a period of time after injection so that the lining can absorb the
water (no less than 24 hours, the time shall be determined according to the local humidity).

5.9.3 Pressure test procedure


Inspect visually all the exposed joints, and fittings, etc. for leaks and other defects after injecting water
and before exerting pressure; when it passed the inspection, the test area shall keep the working pressure
for enough time so as to stabilize the pressure.
Stably increase pressure till the prescribed test pressure after it passed the visual inspection . If
necessary, keep test pressure by a pump within the range of test pressure 0.1 bar for at least 1 hour.

150

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

151

Chapter VI
Xinxing Ductile
Iron Fittings and
Accesseries

152

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

153

Chapter VI
Xinxing Ductile
Iron Fittings and
Accesseries

154

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

6.1 Names and Symbols of the Fittings 158


6.2 Technical Parameters for Fittings and Accesseries 160

Xinxing Ductile Iron Pipes Technical Manual

155

(1) Flanged Spigot (Refer to Figure 1 and Table 1)

(36)T-Type Spigot Cap (Refer to Figure 36 and Table 36)

(2) Socket Spigots Pipe (Refer to Figure 2 and Table 2 )

(37)T-Type Socket Plugs (Refer to Figure 37 and Table 37)

(3) Collars (Refer to Figure 3 and Table 3)

(38)Flexible Couplings (Refer to Figure 38 and Table 38)

(4) Flanged Socket (Refer to Figure 4 and Table 4)

(39)Flange Adaptors (Refer to Figure 39 and Table 39)

(5) Double Spigot Short Pipes (Refer to Figure 5 and Table 5)

(40)Dismantling Joints (Refer to Figure 40 and Table 40)

(6) Double-Socket Bends 90 (Refer to Figure 6 and Table 6)

(41) Flanged Bellmouthes (Refer to Figure 41 and Table 41)

(7) Double-Socket Bends 45 (Refer to Figure 7 and Table 7)

(42) Flanges

(8) Double-Socket Bends 22.5 (Refer to Figure 8 and Table 8)

PN10 (Refer to Figure 42 and Table 42)

(9) Double-Socket Bends 11.25 (Refer to Figure 9 and Table 9)

PN16 (Refer to Figure 42and Table 43)

(10) Socket-Spigot Bends 90 (Refer to Figure 10 and Table 10)

PN25 (Refer to Figure 42 and Table 44)

(11) Socket-Spigot Bends 45 (Refer to Figure 11 and Table 11)

PN40(Refer to Figure 42 and Table 45)

(12) Socket-Spigot Bends 22.5 (Refer to Figure 12 and Table 12)

(43) Welded-on Flanges (Refer to Figure43)

(13) Socket-Spigot Bends 11.25 (Refer to Figure 13 and Table 13)

PN10 (Refer to Figure 43 and Table 46)

(14) Double-Flanged Bends 90 (Refer to Figure 14 and Table 14)

PN16 (Refer to Figure 43 and Table 47)

(15) Double-Flanged Bends 45 (Refer to Figure 15 and Table 15)

PN25(Refer to Figure 43 and Table 48)

(16) Double-Flanged Bends 22.5 (Refer to Figure 16 and Table 16)

(44) Welded Puddle Flanges (Refer to Figure 44 and Table 49)

(17) Double-Flanged Bends 11.25 (Refer to Figure 17 and Table 17)

(45) Blank Flanges

(18) Double-Flanged Bends with Duckfoot 90 (Refer to Figure 18 and Table 18)

PN10(Refer to Figure 45 and Table 50)

(19) Double-Socket Tapers (Refer to Figure 19 and Table 19)

PN16(Refer to Figure 45 and Table 51)

(20) Double-Flanged Tapers (Refer to Figure 20 and Table 20)

PN25(Refer to Figure 45 and Table 52)

(21) Double-Socket offsets (Refer to Figure 21 and Table 21)

(46) Reducing Flanges

(22) Socket-Spigot Offsets (Refer to Figure 22 and Table 22)

PN10(Refer to Figure 46 and Table 53)

(23) Double-Socket Tees with Flanged Branch (Refer to Figure 23 and Table 23)

PN16(Refer to Figure 46 and Table 54)

(24) All Flanged Tees (Refer to Figure 24 and Table 24)

PN25(Refer to Figure 46 and Table 55)

(25) All Socket Tees (Refer to Figure 25 and Table 25)

(47) Flexible Puddle Flanges (Refer to Figure 47 and Table 56)

(26) Socket-Spigot Tees with Socket Branch (Refer to Figure 26 and Table 26)

(48) Bolts for Flange Connection (Refer to Figure 48 and Table 57)

(27) Socket-Spigot Tees with Flange Branch (Refer to Figure 27 and Table 27)

(49) Bolts for K-type joint Connection (Refer to Figure 49 and Table 58)

(28) Double-Socket Level Invert Tees with Flanged Branch (Refer to Figure 28 and Table 28)
(29) All Socket Level Invert Tees (Refer to Figure 29 and Table 29)
(30) Socket Spigot Level Invert Tees with Flanged Branch (Refer to Figure 30 and Table 30)
(31) All Socket Eccentric Tees 45 (Refer to Figure 31 and Table 31)
(32) All Flanged Eccentric Tees 45 (Refer to Figure 32 and Table 32)
(33) All Socket Crosses (Refer to Figure 33 and Table 33)
(34) All Flanged Crosses (Refer to Figure 34 and Table 34)
(35)Socket Spigot Crosses with Double Socket (Refer to Figure 35 and Table 35)

156

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

157

6.1 Names and Symbols of the Fittings

158

DN

Figure No.

Table No.

31

All Socket Eccentric Tees 45

80~600

31

31

Flanged spigots

80~2000

32

All Flanged Eccentric Tees 45

80~600

32

32

Socket Spigots

80~1800

33

All Socket Crosses

80~600

33

33

Collars

80~2000

34

All Flanged Crosses

80~600

34

34

Flanged Sockets

80~2000

35

80~600

35

35

Double-Spigot Short Pipes

80~2000

Socket-Spigot Cross with


Double Socket Branch

Double-Socket Bends 90

80~1400

36

T-Type Spigot Caps

80~1800

36

36

Double-Socket Bends 45

80~2000

37

T-Type Socket Plugs

80~1800

37

37

Double-Socket Bends 22.5

80~2000

38

Flexible Couplings

80~1600

38

38

Double-Socket Bends11.25

80~2000

39

Flange Adaptors

80~1600

39

39

10

Socket-Spigot Bends 90

80~1400

10

10

40

Dismantling Joints

80~1600

40

40

11

Socket-Spigot Bends 45

80~2000

11

11

41

Flanged Bellmouthes

80~2600

41

41

12

Socket-Spigot Bends 22.5

80~2000

12

12

42

Flanges

80~2000

42

4243
4445

13

Socket-Spigot Bends 11.25

80~2000

13

13

43

Welded-on Flanges

40~2000

43

464748

14

Double-Flanged Bends 90

80~1400

14

14

44

Welded Puddle Flanges

80~2000

44

49

15

Double-Flanged Bends 45

80~2000

15

15

45

Blank Flanges

80~2000

45

505152

16

Double-Flanged Bends 22.5

80~2000

16

16

46

Reducing Flanges

80~800

46

535455

17

Double-Flanged Bends 11.25

80~2000

17

17

47

Flexible Puddle Flanges

80~1400

47

56

18

Double-Flanged Bends with


Duckfoot 90

80~1000

18

18

48

Bolts for Flange Connection

80~2000

48

57

19

Double-Socket Tapers

80~2000

19

19

49

Bolts for K-Joint Connection

1600~2600

49

58

20

Double-Flanged Tapers

80~2000

20

20

21

Double-Socket offsets

100~300

21

21

22

Socket-Spigot Offsets

100~300

22

22

23

Double-Socket Tees with Flanged


Branch

100~2000

23

23

24

All Flanged Tees

80~2000

24

24

25

All Socket Tees

80~2000

25

25

26

Socket Spigot Tees


with Socket Branch

80~2000

26

26

27

Socket Spigot Tees with Flanged


Brand

80~2000

27

27

28

Double Socket Level Invert Tees


with Flanged Branch

80~2000

28

28

29

All Socket Level Invert Tees

100~2000

29

29

30

Socket Spigot Level Invert Tees


with Flanged Branch

80~2000

30

30

No.

Product Name

XINXING PIPES

Symbol

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

159

6.2 Technical Parameters for Fittings and Accesseries


(1)Flanged Spigots (Refer to Figure 1 and Table 1)

Figure 1 Flanged Spigots

Table 1 Technical Parameters for Flanged Spigots

Unit:mm

DN

DN

80

350

700

14.4

600

100

7.2

360

800

15.6

600

125

7.5

370

900

16.8

600

150

7.8

380

1000

18

600

200

8.4

400

1100

19.2

600

250

420

1200

20.4

600

300

9.6

440

1400

22.8

710

350

10.2

460

1500

24

750

400

10.8

480

1600

25.2

780

450

11.4

500

1800

27.6

850

500

12

520

2000

30

920

600

13.2

560

(2)Socket Spigots (Refer to Figure 2 and Table 2 )

Figure 2 Socket Spigot

160

XINXING PIPES

Unit:mm

Xinxing Ductile Iron Pipes Technical Manual

Table 2 Technical Parameters for Socket Spigots

Unit:mm

DN

DN

80

255

600

13.2

425

100

7.2

255

700

14.4

460

125

7.5

265

800

15.6

475

150

7.8

270

900

16.8

500

200

8.4

285

1000

18

515

250

300

1100

19.2

540

300

9.6

315

1200

20.4

565

350

10.2

335

1400

22.8

620

400

10.8

355

1600

25.2

650

450

11.4

365

1800

27.6

700

500

12

385

(3)Collars (Refer to Figure 3 and Table 3)

Figure 3 Collars
Table 3 Technical Parameters for Collars

Unit:mm

DN

DN

80

160

700

14.4

220

100

7.2

160

800

15.6

230

125

7.5

165

900

16.8

240

150

7.8

165

1000

18

250

200

8.4

170

1100

19.2

260

250

175

1200

20.4

270

300

9.6

180

1400

22.8

310

350

10.2

185

1500

24

350

400

10.8

190

1600

25.2

360

450

11.4

195

1800

27.6

380

500

12

200

2000

30

400

600

13.2

210

Xinxing Ductile Iron Pipes Technical Manual

161

(4)Flange Sockets (Refer to Figure 4 and Table 4)

(5)Double Spigot Short Pipes (Refer to Figure 5 and Table 5)

Figure 4 Flanged Sockets

Table 4 Technical Parameters for Flanged Sockets

162

Figure 5 Double Spigot Short Pipes

Unit:mm

Table 5 Technical Parameters for Double Spigot Short Pipes

Unit:mm

DN

DN

DN

DE

DN

DE

80

130

700

14.4

190

80

98

700

738

14.4

100

7.2

130

800

15.6

200

100

118

7.2

800

842

15.6

125

7.5

135

900

16.8

210

125

144

7.5

900

945

16.8

150

7.8

135

1000

18

220

150

170

7.8

1000

1048

18

200

8.4

140

1100

19.2

230

200

222

8.4

1100

1152

19.2

250

145

1200

20.4

240

250

274

1200

1255

20.4

300

9.6

150

1400

22.8

310

300

326

9.6

1400

1462

22.8

350

10.2

155

1500

24

330

350

378

10.2

1500

1565

24

400

10.8

160

1600

25.2

330

400

429

10.8

1600

1668

25.2

450

11.4

165

1800

27.6

350

450

480

11.4

1800

1875

27.6

500

12

170

2000

30

370

500

532

12

2000

2082

30

600

13.2

180

600

635

13.2

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

163

(6)Double Socket Bends 90 (Refer to Figure 6 and Table 6)

(7)Double Socket Bends 45 (Refer to Figure 7 and Table 7)

Figure 6 Double Socket Bends 90

Table 6 Technical Parameters for Double Socket Bends 90

164

Figure 7 Double Socket Bends 45

Unit:mm

Table 7 Technical Parameters for Double Socket Bends 45

Unit:mm

DN

DN

DN

DN

80

100

500

12

520

80

50

700

14.4

330

100

7.2

110

600

13.2

620

100

7.2

60

800

15.6

370

125

7.5

145

700

14.4

720

125

7.5

75

900

16.8

415

150

7.8

170

800

15.6

820

150

7.8

85

1000

18

460

200

8.4

220

900

16.8

920

200

8.4

110

1100

19.2

505

250

270

1000

18

1020

250

130

1200

20.4

550

300

9.6

320

1100

19.2

1120

300

9.6

150

1400

22.8

515

350

10.2

370

1200

20.4

1220

350

10.2

175

1500

24

540

400

10.8

420

1400

22.8

1220

400

10.8

195

1600

25.2

565

450

11.4

470

450

11.4

220

1800

27.6

610

500

12

240

2000

30

660

600

13.2

285

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

165

(8)Double Socket Bends 22.5 (Refer to Figure 8 and Table 8)

(9)Double Socket Bends 11.25 (Refer to Figure 9 and Table 9)

Figure 8 Double Socket Bends 22.5

Table 8 Technical Parameters for Double Socket Bends 22.5

166

Figure 9 Double Socket Bends 11.25

Unit:mm

Table 9 Technical Parameters for Double Socket Bends 11.25

Unit:mm

DN

DN

DN

DN

80

40

700

14.4

175

80

30

700

14.4

95

100

7.2

40

800

15.6

195

100

7.2

30

800

15.6

110

125

7.5

50

900

16.8

220

125

7.5

35

900

16.8

120

150

7.8

55

1000

18

240

150

7.8

35

1000

18

130

200

8.4

65

1100

19.2

260

200

8.4

40

1100

19.2

140

250

75

1200

20.4

285

250

50

1200

20.4

150

300

9.6

85

1400

22.8

260

300

9.6

55

1400

22.8

130

350

10.2

95

1500

24

270

350

10.2

60

1500

24

140

400

10.8

110

1600

25.2

280

400

10.8

65

1600

25.2

140

450

11.4

120

1800

27.6

305

450

11.4

70

1800

27.6

155

500

12

130

2000

30

330

500

12

75

2000

30

165

600

13.2

150

600

13.2

85

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

167

(11)Socket Spigot Bends 45 (Refer to Figure 11 and Table 11)

(10)Socket Spigot Bends 90 (Refer to Figure 10 and Table 10)

Figure 10 Socket Spigot Bends 90


Figure 11 Socket Spigot Bends 45

Table 10 Technical Parameters for Socket Spigot Bends 90

168

Unit:mm

Table 11 Technical Parameters for Socket Spigot Bends 45

Unit:mm

DN

DN

DN

DN

80

100

280

450

11.4

470

670

80

50

235

700

14.4

330

580

100

7.2

110

300

500

12

520

720

100

7.2

60

245

800

15.6

370

620

125

7.5

145

325

600

13.2

620

820

125

7.5

75

255

900

16.8

415

665

150

7.8

170

350

700

14.4

720

900

150

7.8

85

265

1000

18

460

760

200

8.4

220

400

800

15.6

820

1000

200

8.4

110

290

1100

19.2

505

805

250

270

450

900

16.8

920

1100

250

130

310

1200

20.4

550

850

300

9.6

320

500

1000

18

1020

1200

300

9.6

150

330

1400

22.8

515

815

350

10.2

370

550

1200

20.4

1220

1400

350

10.2

175

355

1500

24

540

840

400

10.8

420

600

1400

22.8

1220

1600

400

10.8

195

375

1600

25.2

565

925

450

11.4

220

420

1800

27.6

610

970

500

12

240

440

2000

30

660

1060

600

13.2

285

485

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

169

(12)Socket Spigot Bends 22.5 (Refer to Figure 12 and Table 12)

(13)Socket Spigot Bends 11.25 (Refer to Figure 13 and Table 13)

Figure 12 Socket Spigot Bends 22.5

Figure 13 Socket Spigot Bends 11.25

Table 12 Technical Parameters for Socket Spigot Bends 22.5

170

Unit:mm

Table 13 Technical Parameters for Socket Spigot Bends 11.25

Unit:mm

DN

DN

DN

DN

80

40

220

700

14.4

175

425

80

30

210

700

14.4

95

345

100

7.2

40

220

800

15.6

195

445

100

7.2

30

210

800

15.6

110

360

125

7.5

50

230

900

16.8

220

470

125

7.5

35

215

900

16.8

120

370

150

7.8

55

235

1000

18

240

540

150

7.8

35

215

1000

18

130

430

200

8.4

65

245

1100

19.2

260

560

200

8.4

40

220

1100

19.2

140

440

250

75

255

1200

20.4

285

585

250

50

230

1200

20.4

150

450

300

9.6

85

265

1400

22.8

260

560

300

9.6

55

235

1400

22.8

130

430

350

10.2

95

275

1500

24

270

570

350

10.2

60

240

1500

24

140

440

400

10.8

110

290

1600

25.2

280

640

400

10.8

65

245

1600

25.2

140

500

450

11.4

120

320

1800

27.6

305

665

450

11.4

70

270

1800

27.6

155

515

500

12

130

330

2000

30

330

730

500

12

75

275

2000

30

165

565

600

13.2

150

350

600

13.2

85

285

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

171

(14)Double Flanged Bends 90 (Refer to Figure 14 and Table 14)

(15)Double Flanged Bends 45 (Refer to Figure 15 and Table 15)

Figure 15 Double Flanged Bends 45

Figure 14 Double Flanged Bends 90

Table 14 Technical Parameters for Double Flanged Bends 90

172

Unit:mm

Table 15 Technical Parameters for Double Flanged Bends 45

Unit:mm

DN

DN

DN

DN

80

165

450

11.4

550

80

130

700

14.4

480

100

7.2

180

500

12

600

100

7.2

140

800

15.6

530

125

7.5

200

600

13.2

700

125

7.5

150

900

16.8

580

150

7.8

220

700

14.4

800

150

7.8

160

1000

18

630

200

8.4

260

800

15.6

900

200

8.4

180

1100

19.2

695

250

350

900

16.8

1000

250

350

1200

20.4

750

300

9.6

400

1000

18

1100

300

9.6

400

1400

22.8

775

350

10.2

450

1200

20.4

1300

350

10.2

300

1500

24

810

400

10.8

500

1400

22.8

1470

400

10.8

325

1600

25.2

845

450

11.4

350

1800

27.6

910

500

12

375

2000

30

980

600

13.2

425

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

173

(16)Double Flanged Bends 22.5 (Refer to Figure 16 and Table 16)

(17)Double Flanged 11.25Bend (Refer to Figure 17 and Table 17)

Figure 17 Double Flanged 11.25Bend

Figure 16 Double Flanged Bends 22.5

Table 16 Technical Parameters for Double Flanged Bends 22.5

174

Unit:mm

Table 17 Technical Parameters for Double Flanged 11.25Bend

Unit:mm

DN

DN

DN

DN

80

125

600

13.2

405

80

125

600

13.2

405

100

7.2

135

700

14.4

300

100

7.2

135

700

14.4

205

125

7.5

150

800

15.6

330

125

7.5

80

800

15.6

230

150

7.8

155

900

16.8

360

150

7.8

155

900

16.8

245

200

8.4

170

1000

18

390

200

8.4

170

1000

18

265

250

340

1100

19.2

420

250

340

1100

19.2

320

300

9.6

390

1200

20.4

450

300

9.6

390

1200

20.4

360

350

10.2

290

1400

22.8

460

350

10.2

290

1400

22.8

380

400

10.8

310

1600

25.2

470

400

10.8

310

1600

25.2

400

450

11.4

335

1800

27.6

480

450

11.4

335

1800

27.6

410

500

12

360

2000

30

520

500

12

360

2000

30

415

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

175

(18)Double-Flanged Bends with Duckfoot 90 (Refer to Figure 18 and Table 18)

(19)Double-Socket Tapers (Refer to Figure 19 and Table 19)

Figure 19 Double-Socket Tapers

Figure 18 Double-Flanged Bends with Duckfoot 90

Table 18 Technical Parameters for Double-Flanged Bends with Duckfoot 90

Unit:mm

Table 19 Technical Parameters for Double-Socket Tapers

DN

DN

DN

e1

dn

e2

80

165

110

180

400

10.8

500

320

500

100

7.2

80

100

7.2

180

125

200

450

11.4

550

355

550

7.5

200

140

225

500

12

600

385

600

7.8

80

125

150

150

7.8

220

160

250

600

13.2

700

450

700

200

8.4

260

190

300

700

14.4

800

515

800

250

350

225

350

800

15.6

900

580

300

9.6

400

255

400

900

16.8

1000

350

10.2

450

290

450

1000

18

1100

dn

e2

90

200

8.4

1080

190

250

980

100

7.2

150

300

9.6

880

80

290

350

10.2

780

100

7.2

250

400

10.8

680

900

150

7.8

150

450

11.4

580

645

1000

80

390

500

12

480

710

1100

100

7.2

330

600

13.2

280

150

7.8

250

400

10.8

880

200

8.4

150

450

11.4

780

80

490

500

12

680

100

7.2

430

600

13.2

480

150

7.8

350

700

14.4

280

200

8.4

250

400

10.8

1080

250

150

450

11.4

980

80

600

500

12

880

100

7.2

560

600

13.2

680

150

7.8

460

700

14.4

480

200

8.4

360

800

15.6

280

200

250

300

350

176

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

8.4

9.6

10.2

Xinxing Ductile Iron Pipes Technical Manual

DN

700

800

900

e1

Unit:mm

14.4

15.6

16.8

177

350

400

450

500

600

102

10.8

11.4

12

13.2

250

260

300

9.6

160

80

700

100

7.2

150

(20)Double-Flanged Tapers (Refer to Figure 20 and Table 20)

600

13.2

880

700

14.4

680

800

15.6

480

660

900

16.8

280

7.8

560

600

13.2

1080

200

8.4

460

700

14.4

880

250

360

800

15.6

680

300

9.6

260

900

16.8

480

350

10.2

160

1000

18

280

80

800

600

13.2

1280

100

7.2

760

700

14.4

1080

150

7.8

660

800

15.6

880

200

8.4

560

900

16.8

680

250

460

1000

18

480

300

9.6

360

1100

19.2

280

350

10.2

260

600

13.2

960

400

10.8

160

700

14.4

860

80

900

800

15.6

760

100

7.2

860

900

16.8

660

150

7.8

760

1000

18

560

200

8.4

660

1100

19.2

460

DN

e1

dn

e2

250

560

1200

20.4

360

100

7.2

80

300

9.6

460

800

15.6

960

150

7.8

80

350

10.2

360

900

16.8

860

400

10.8

260

1000

18

760

450

11.4

160

1200

20.4

560

80

1100

1400

22.8

100

7.2

1060

1000

150

7.8

960

200

8.4

860

250

300

1000

1100

1200

1400

18

19.2

20.4

22.8

Figure 20 Double-Flanged Tapers

Table 20 Technical Parameters for Double-Flanged Tapers

dn

e2

200

250

9.0

1050

300

300

9.6

1000

100

7.2

280

350

10.2

900

80

600

400

10.8

800

100

7.2

600

450

11.4

750

360

150

7.8

300

500

12

700

18

960

80

650

600

13.2

600

1200

20.4

760

100

7.2

600

400

10.8

1030

1400

22.8

560

150

7.8

600

450

11.4

900

760

1600

25.2

360

200

8.4

300

500

12.0

800

9.6

660

1000

18

1160

80

700

600

13.2

700

350

10.2

560

1200

20.4

960

100

7.2

700

700

14.4

600

400

10.8

460

1400

22.8

760

150

7.8

650

400

10.8

1100

450

11.4

360

1600

25.2

560

200

8.4

600

450

11.4

1050

500

12

260

1800

27.6

360

250

300

500

12

1000

80

750

600

13.2

800

1600

1800

2000

25.2

27.6

30

200

250

300

350

178

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

8.4

9.6

10.2

Xinxing Ductile Iron Pipes Technical Manual

DN

700

800

900

e1

Unit:mm

14.4

15.6

16.8

179

350

400

450

500

600

180

XINXING PIPES

10.2

10.8

11.4

12

13.2

100

7.2

750

700

14.4

700

150

7.8

700

800

15.6

600

200

8.4

650

600

13.2

1000

250

9.0

600

700

14.4

800

300

9.6

300

800

15.6

700

80

800

900

16.8

600

100

7.2

800

600

13.2

1100

150

7.8

750

700

14.4

1000

200

8.1

700

800

15.6

800

250

9.0

650

900

16.8

700

300

9.6

600

1000

18

600

350

10.2

300

600

13.2

1150

80

900

700

14.4

1100

100

7.2

900

800

15.6

1000

150

7.8

800

900

16.8

800

200

8.4

750

1000

18

700

250

9.0

700

1100

19.2

600

300

9.6

650

600

13.2

860

350

10.2

600

700

14.4

850

400

10.8

300

800

15.6

950

80

950

900

16.8

1100

100

7.2

950

1000

18

1000

150

7.8

900

1100

19.2

800

200

8.4

800

1200

20.4

700

250

9.0

750

1400

22.8

600

300

9.6

700

1000

18

1650

350

10.2

650

1100

19.2

1465

400

10.8

600

1200

20.4

1000

450

11.4

300

1400

22.8

910

80

1050

1000

18

1760

100

7.2

1050

1200

20.4

1710

150

7.8

1000

1400

22.8

1340

200

8.4

950

1500

24

1550

250

9.0

900

1600

25.2

970

300

9.6

800

1000

18

2160

350

10.2

750

1200

20.4

2140

900

1000

1100

1200

1400

1500

1600

1800

2000

16.8

18

19.2

20.4

22.8

24

25.2

27.6

30

Xinxing Ductile Iron Pipes Technical Manual

600

700

13.2

14.4

400

10.8

700

450

11.4

650

500

12

600

200

8.4

1100

200

30

1400

22.8

1770

1500

24

1585

1600

25.2

1400

1800

27.2

1030

(21)Double-Socket offsets (Refer to Figure 21 and Table 21)

Figure 21 Double-Socket offsets

Table 21 Technical Parameters for Double-Socket offsets

Unit:mm

DN

100

7.2

475

200

150

7.8

625

250

200

8.4

655

300

250

665

300

300

9.6

670

300

Xinxing Ductile Iron Pipes Technical Manual

181

(22)Socket-Spigot Offsets (Refer to Figure 22 and Table 22)

(23)Double-Socket Tees with Flanged Branch (Refer to Figure 23 and Table 23)

Figure 23 Double-Socket Tees with Flanged Branch

Figure 22 Socket-Spigot Offsets

Table 22 Technical Parameters for Socket-Spigot Offsets

Unit:mm

Table 23 Technical Parameters for Double-Socket Tees with Flanged Branch


Body

Lu

100

7.2

470

150

DN

dn

e1

150

7.8

475

150

80

8.1

170

80

8.1

200

8.4

600

200

80

700

250

8.4

170

250

100

190

300

9.6

800

300

150

200

XINXING PIPES

Body

DN

125

182

Branch

Xinxing Ductile Iron Pipes Technical Manual

8.7

9.1

9.8

Unit:mm

dn

e1

165

590

400

12.6

675

8.1

175

640

450

13.3

665

100

8.4

180

690

500

14

670

170

80

8.1

190

800

600

15.4

685

195

100

8.4

195

920

700

16.8

700

225

125

8.7

200

1040

800

18.2

715

170

80

8.1

205

1170

900

19.6

750

195

100

8.4

210

240

80

8.1

670

230

125

8.7

215

260

100

8.4

670

255

150

9.1

220

290

125

8.7

675

175

80

8.1

235

310

150

9.1

680

200

100

8.4

240

360

200

9.8

705

235

125

8.7

240

420

250

10.5

705

255

150

9.1

250

480

300

11.2

710

315

200

9.8

260

530

350

11.9

720

Xinxing Ductile Iron Pipes Technical Manual

DN

900

1000

Branch

19.6

21

183

250

300

350

400

450

184

XINXING PIPES

10.5

11.2

11.9

12.6

13.3

180

80

8.1

265

595

400

12.6

735

200

100

8.4

270

640

450

13.3

725

230

125

8.7

275

690

500

14

260

150

9.1

280

810

600

315

200

9.8

290

930

375

250

10.5

300

180

80

8.1

205

100

230

480

350

11.9

430

940

700

16.8

885

560

400

12.6

450

1070

800

18.2

915

730

620

450

13.3

460

1190

900

19.6

920

15.4

745

190

80

8.1

400

1300

1000

21

945

700

16.8

760

215

100

8.4

420

1520

1200

23.8

955

1040

800

18.2

775

240

125

8.7

420

340

80

8.1

870

295

1160

900

19.6

790

280

150

9.1

420

420

100

8.4

875

8.4

300

1290

1000

21

825

330

200

9.8

440

450

125

8.7

880

125

8.7

300

240

80

8.1

730

380

250

10.5

440

480

150

9.1

880

260

150

9.1

310

260

100

8.4

730

440

300

11.2

440

540

200

9.8

890

320

200

9.8

320

290

125

8.7

735

490

350

11.9

450

560

250

10.5

895

380

250

10.5

330

310

150

9.1

740

565

400

12.6

480

650

300

11.2

905

435

300

11.2

340

360

200

9.8

745

600

450

13.3

480

710

350

11.9

910

185

80

8.1

325

420

250

10.5

755

680

500

14

500

770

400

12.6

920

205

100

8.4

330

480

300

11.2

760

195

80

8.1

460

830

450

13.3

925

230

125

8.7

330

530

350

11.9

770

200

100

8.4

460

880

500

14

935

270

150

9.1

340

600

400

12.6

795

240

125

8.7

465

1030

600

15.4

980

325

200

9.8

350

650

450

13.3

795

260

150

9.1

470

1120

700

16.8

990

385

250

10.5

360

700

500

14

795

340

200

9.8

500

1260

800

18.2

1010

420

300

11.2

370

830

600

15.4

825

380

250

10.5

500

1350

900

19.6

1020

495

350

11.9

380

940

700

16.8

830

430

300

11.2

500

1495

1000

21

1040

185

80

8.1

355

1050

800

18.2

835

490

350

11.9

510

1580

1100

22.4

1045

210

100

8.4

360

1170

900

19.6

850

570

400

12.6

540

1700

1200

23.8

1050

230

125

8.7

360

1280

1000

21

870

610

450

13.3

540

1930

1400

26.6

1070

270

150

9.1

370

1390

1100

22.4

880

670

500

14

540

580

200

9.8

1030

325

200

9.8

380

240

80

8.1

790

800

600

15.4

580

635

250

10.5

1040

385

250

10.5

390

260

100

8.4

790

210

80

8.1

490

695

300

11.2

1045

440

300

11.2

400

290

125

8.7

795

230

100

8.4

490

810

400

12.6

1060

480

350

11.9

410

310

150

9.1

800

250

125

8.7

495

925

500

14

1075

560

400

12.6

420

360

200

9.8

805

280

150

9.1

500

1040

600

15.4

1090

190

80

8.1

370

420

250

10.5

815

345

200

9.8

525

1275

800

18.2

1120

215

100

8.4

390

480

300

11.2

820

390

250

10.5

525

1505

1000

21

1150

230

125

8.7

390

530

350

11.9

830

440

300

11.2

525

1740

1200

23.8

1180

270

150

9.1

400

590

400

12.6

835

500

350

11.9

530

1970

1400

26.6

1210

330

200

9.8

410

650

450

13.3

845

575

400

12.6

555

2200

1600

29.4

1240

390

250

10.5

420

710

500

14

850

610

450

13.3

545

595

200

9.8

1150

445

300

11.2

430

840

600

15.4

885

680

500

14

550

650

250

10.5

1150

1000

1100

1200

21

22.4

23.8

Xinxing Ductile Iron Pipes Technical Manual

450

500

600

700

13.3

14

15.4

16.8

Xinxing Ductile Iron Pipes Technical Manual

1200

1400

1600

1800

23.8

26.6

29.4

32.2

185

700

800

900

16.8

18.2

19.6

770

600

15.4

565

705

300

11.2

1155

925

700

16.8

600

820

400

12.6

1170

240

80

8.1

550

940

500

14

1185

260

100

8.4

550

1055

600

15.4

1200

290

125

8.7

555

1285

800

18.2

1230

310

150

9.1

560

1520

1000

21

1260

350

200

9.8

585

1750

1200

23.8

1290

420

250

10.5

585

1980

1400

26.6

1320

480

300

11.2

585

2215

1600

29.4

1350

530

350

11.9

590

2445

1800

32.2

1380

580

400

12.6

615

600

200

9.8

1250

640

450

13.3

615

660

250

10.5

1260

690

500

14

615

720

300

11.2

1270

800

600

15.4

625

835

400

12.6

1290

920

700

16.8

640

950

500

14

1305

1030

800

18.2

655

1065

600

15.4

1310

240

80

8.1

605

1300

800

18.2

1340

260

100

8.4

610

1530

1000

21

1370

290

125

8.7

615

1760

1200

23.8

1400

310

150

9.1

620

1995

1400

26.6

1430

355

200

9.8

645

2225

1600

29.4

1460

420

250

10.5

645

2460

1800

32.2

1490

480

300

11.2

650

2690

2000

35

1520

530

350

11.9

660

1800

2000

32.2

35

(24)All Flanged Tees (Refer to Figure 24 and Table 24)

Figure 24 All Flanged Tees

Table 24 Technical Parameters for All Flanged Tees


Body
e

dn

e1

80

8.1

330

80

8.1

100

8.4

330

80

360

150

200

250

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Body

DN

125

186

Branch

8.7

9.1

9.8

10.5

Unit:mm

dn

e1

165

980

450

13.3

675

8.1

175

1040

500

14

680

100

8.4

180

1500

600

15.4

705

400

80

8.1

190

1500

700

16.8

710

400

100

8.4

195

1500

800

18.2

725

400

125

8.7

200

1500

900

19.6

750

440

80

8.1

205

620

80

8.1

680

440

100

8.4

210

640

100

8.4

680

440

125

8.7

215

670

125

8.7

685

440

150

9.1

220

690

150

9.1

690

520

80

8.1

235

770

200

9.8

705

520

100

8.4

240

800

250

10.5

705

435

125

8.7

240

840

300

11.2

710

520

150

9.1

250

910

350

11.9

720

520

200

9.8

260

990

400

12.6

735

405

80

8.1

265

1020

450

13.3

735

700

100

8.4

275

1080

500

14

740

Xinxing Ductile Iron Pipes Technical Manual

DN

900

1000

Branch

19.6

21

187

250

300

350

400

450

188

XINXING PIPES

10.5

11.2

11.9

12.6

13.3

485

125

8.7

280

1650

600

15.4

765

485

150

9.1

280

1650

700

16.8

700

200

9.8

325

1650

800

700

250

10.5

350

1650

425

80

8.1

295

800

100

8.4

480

125

505

950

450

13.3

475

1700

1000

21

945

770

1000

80

8.1

400

1910

1200

23.8

955

18.2

785

1000

100

8.4

400

820

80

8.1

870

900

19.6

800

1000

125

8.7

400

860

100

8.4

875

1650

1000

21

825

1000

150

9.1

400

880

125

8.7

880

300

610

80

8.1

740

1000

200

9.8

400

900

150

9.1

885

8.7

300

640

100

8.4

740

1000

250

10.5

400

910

200

9.8

890

150

9.1

310

670

125

8.7

745

1000

300

11.2

500

960

250

10.5

900

800

200

9.8

350

700

150

9.1

750

1000

350

11.9

500

1140

300

11.2

905

620

250

10.5

330

750

200

9.8

755

1000

400

12.6

500

1210

350

11.9

915

800

300

11.2

400

810

250

10.5

765

1000

450

13.3

500

1250

400

12.6

920

445

80

8.1

325

860

300

11.2

770

1000

500

14

500

1270

450

13.3

930

850

100

8.4

325

920

350

11.9

780

1100

80

8.1

450

1290

500

14

960

480

125

8.7

325

980

400

12.6

795

1100

100

8.4

450

1320

600

15.4

980

530

150

9.1

340

1030

450

13.3

795

1100

125

8.7

450

1440

700

16.8

990

850

200

9.8

325

1090

500

14

800

1100

150

9.1

450

1540

800

18.2

1010

645

250

10.5

360

1210

600

15.4

825

1100

200

9.8

450

1670

900

19.6

1020

680

300

11.2

350

1480

700

16.8

830

1100

250

10.5

450

1760

1000

21

1040

850

350

11.9

425

1540

800

18.2

845

1100

300

11.2

550

1880

1100

22.4

1055

470

80

8.1

355

1600

900

19.6

860

1100

350

11.9

550

1980

1200

23.8

1070

900

100

8.4

350

1660

1000

21

875

1100

400

12.6

550

2200

1400

26.6

1100

500

125

8.7

345

1780

1100

22.4

890

1100

450

13.3

550

1575

600

15.4

1035

550

150

9.1

370

610

80

8.1

795

1100

500

14

550

2040

1000

21

1095

900

200

9.8

360

640

100

8.4

800

1100

600

15.4

550

920

200

9.8

1040

665

250

10.5

390

670

125

8.7

805

500

80

8.1

500

980

250

10.5

1040

725

300

11.2

400

700

150

9.1

810

520

100

8.4

500

1150

300

11.2

1045

760

350

11.9

390

750

200

9.8

815

550

125

8.7

505

1270

400

12.6

1055

900

400

12.6

450

810

250

10.5

825

570

150

9.1

510

1300

500

14

1070

470

80

8.1

370

870

300

11.2

830

650

200

9.8

525

1380

600

15.4

1090

950

100

8.4

375

930

350

11.9

840

680

250

10.5

525

1600

800

18.2

1120

530

125

8.7

375

990

400

12.6

845

740

300

11.2

530

1820

1000

21

1150

570

150

9.1

400

1040

450

13.3

855

790

350

11.9

540

2040

1200

23.8

1180

950

200

9.8

375

1100

500

14

860

870

400

12.6

555

2260

1400

26.6

1210

690

250

10.5

420

1240

600

15.4

885

900

450

13.3

555

2480

1600

29.4

1240

745

300

11.2

430

1330

700

16.8

890

960

500

14

560

940

200

9.8

1140

790

350

11.9

420

1470

800

18.2

915

1180

600

15.4

575

1010

250

10.5

1145

860

400

12.6

450

1570

900

19.6

920

1200

700

16.8

600

1180

300

11.2

1150

1000

1100

1200

21

22.4

23.8

Xinxing Ductile Iron Pipes Technical Manual

450

500

600

700

13.3

14

15.4

16.8

Xinxing Ductile Iron Pipes Technical Manual

1200

1400

1500

1600

1800

23.8

26.6

28

29.4

32.2

189

800

900

18.2

19.6

540

80

8.1

560

1320

400

12.6

1165

560

100

8.4

560

1400

500

14

1185

590

125

8.7

565

1440

600

15.4

1200

610

150

9.1

570

1660

800

18.2

1230

690

200

9.8

585

1880

1000

21

1260

720

250

10.5

585

2100

1200

23.8

1290

760

300

11.2

590

2320

1400

26.6

1320

830

350

11.9

600

2540

1600

29.4

1350

910

400

12.6

615

2760

1800

32.2

1380

940

450

13.3

615

980

200

9.8

1240

1000

500

14

620

1055

250

10.5

1245

1350

600

15.4

645

1200

300

11.2

1250

1330

700

16.8

665

1350

400

12.6

1285

1350

800

18.2

675

1450

500

14

1295

580

80

8.1

620

1500

600

15.4

1310

600

100

8.4

620

1720

800

18.2

1340

630

125

8.7

625

1940

1000

21

1370

650

150

9.1

630

2160

1200

23.8

1400

730

200

9.8

645

2380

1400

26.6

1430

760

250

10.5

645

2600

1600

29.4

1460

800

300

11.2

650

2820

1800

32.2

1490

870

350

11.9

660

2950

2000

35

1520

950

400

12.6

675

1800

2000

132

35

(25)All Socket Tees (Refer to Figure 25 and Table 25)

Figure 25All Socket Tees

Table 25 Technical Parameters for All Socket Tees


Body
e

Lu

dn

e1

Lu

80

8.1

170

80

8.1

100

8.4

170

80

190

150

200

250

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Body

DN

125

190

Branch

8.7

9.1

9.8

10.5

Unit:mm

Lu

dn

e1

Lu

85

590

400

12.6

530

8.1

95

640

450

13.3

535

100

8.4

95

690

500

14

535

170

80

8.1

105

800

600

15.4

535

195

100

8.4

110

920

700

16.8

535

225

125

8.7

110

1040

800

18.2

550

170

80

8.1

120

1150

900

19.6

575

195

100

8.4

120

240

80

8.1

560

230

125

8.7

125

260

100

8.4

560

255

150

9.1

125

290

125

8.7

560

175

80

8.1

145

310

150

9.1

570

200

100

8.4

145

360

200

9.8

570

230

125

8.7

145

420

250

10.5

570

255

150

9.1

150

480

300

11.2

575

315

200

9.8

155

530

350

11.9

575

180

80

8.1

170

590

400

12.6

580

200

100

8.4

170

640

450

13.3

585

230

125

8.7

175

690

500

14

585

Xinxing Ductile Iron Pipes Technical Manual

DN

900

1000

Branch

19.6

21

191

250

300

350

400

450

192

XINXING PIPES

10.5

11.2

11.9

12.6

13.3

260

150

9.1

175

810

600

15.4

585

200

80

8.1

295

315

200

9.8

180

930

700

16.8

585

230

100

8.4

295

375

250

10.5

190

1040

800

18.2

605

250

125

8.7

190

80

8.1

195

1160

900

19.6

605

280

150

205

100

8.4

195

1270

1000

21

635

330

240

125

8.7

200

240

80

8.1

605

260

150

9.1

200

260

100

8.4

320

200

9.8

205

290

125

375

250

10.5

210

310

435

300

11.2

220

180

80

8.1

200

100

240

1290

1000

21

710

1520

1200

23.8

760

300

250

80

8.1

765

9.1

300

270

100

8.4

765

200

9.8

310

300

125

8.7

765

380

250

10.5

310

330

150

9.1

765

605

440

300

11.2

320

390

200

9.8

765

8.7

605

490

350

11.9

325

440

250

10.5

765

150

9.1

605

540

400

12.6

330

480

300

11.2

770

370

200

9.8

605

600

450

13.3

335

530

350

11.9

770

220

430

250

10.5

605

660

500

14

340

590

400

12.6

770

8.4

220

490

300

11.2

605

180

80

8.1

345

650

450

13.3

770

125

8.7

225

540

350

11.9

610

200

100

8.4

345

710

500

14

770

250

150

9.1

225

600

400

12.6

610

250

125

8.7

350

820

600

15.4

775

300

200

9.8

230

640

450

13.3

610

260

150

9.1

350

940

700

16.8

785

360

250

10.5

240

690

500

14

615

320

200

9.8

360

1050

800

18.2

815

420

300

11.2

245

810

600

15.4

620

380

250

10.5

360

1170

900

19.6

815

480

350

11.9

250

930

700

16.8

630

430

300

11.2

370

1290

1000

21

815

170

80

8.1

245

1040

800

18.2

660

490

350

11.9

375

1400

1100

22.4

825

190

100

8.4

245

1160

900

19.6

665

550

400

12.6

380

1520

1200

23.8

835

240

125

8.7

250

1270

1000

21

670

610

450

13.3

385

1740

1400

26.6

855

250

150

9.1

250

1380

1100

22.4

680

670

500

14

390

855

600

15.4

850

310

200

9.8

255

240

80

8.1

665

780

600

15.4

400

1320

1000

21

895

360

250

10.5

260

260

100

8.4

665

210

80

8.1

395

400

200

9.8

865

420

300

11.2

265

290

125

8.7

665

230

100

8.4

405

455

250

10.5

865

480

350

11.9

275

310

150

9.1

675

250

125

8.7

405

515

300

11.2

870

540

400

12.6

280

360

200

9.8

675

280

150

9.1

405

630

400

12.6

880

180

80

8.1

270

420

250

10.5

675

330

200

9.8

415

745

500

14

890

200

100

8.4

270

480

300

11.2

680

390

250

10.5

415

860

600

15.4

900

250

125

8.7

275

530

350

11.9

685

440

300

11.2

415

1095

800

18.2

925

260

150

9.1

275

590

400

12.6

685

500

350

11.9

420

1325

1000

21

945

310

200

9.8

280

650

450

13.3

695

560

400

12.6

425

1560

1200

23.8

965

370

250

10.5

285

710

500

14

695

610

450

13.3

430

1970

1400

26.6

1030

430

300

11.2

290

820

600

15.4

695

680

500

14

430

2200

1600

29.4

1050

480

350

11.9

300

940

700

16.8

695

770

600

15.4

430

410

200

9.8

970

540

400

12.6

305

1050

800

18.2

710

910

700

16.8

455

470

250

10.5

970

600

450

13.3

310

1170

900

19.6

710

240

80

8.1

445

530

300

11.2

970

1000

1100

1200

21

22.4

23.8

Xinxing Ductile Iron Pipes Technical Manual

500

600

700

800

14

15.4

16.8

18.2

Xinxing Ductile Iron Pipes Technical Manual

1200

1400

1500

1600

1800

23.8

26.6

28

29.4

32.2

193

800

900

18.2

19.6

(26)Socket-Spigot Tees with Socket Branch (Refer to Figure 26 and Table 26)

260

100

8.4

455

640

400

12.6

980

290

125

8.7

455

760

500

14

990

310

150

9.1

460

875

600

15.4

1000

360

200

9.8

465

1105

800

18.2

1025

420

250

10.5

465

1340

1000

21

1045

480

300

11.2

470

1570

1200

23.8

1065

530

350

11.9

475

1800

1400

26.6

1090

590

400

12.6

475

2215

1600

29.4

1150

640

450

13.3

485

2260

1800

32.2

1130

690

500

14

485

420

200

9.8

1080

800

600

15.4

485

540

300

11.2

1080

920

700

16.8

495

650

400

12.6

1080

1030

800

18.2

515

770

500

14

1090

240

80

8.1

505

885

600

15.4

1100

260

100

8.4

505

1300

800

18.2

1165

290

125

8.7

505

1350

1000

21

1185

310

150

9.1

515

1760

1200

23.8

1210

360

200

9.8

520

1815

1400

26.6

1190

420

250

10.5

520

2225

1600

29.4

1250

480

300

11.2

525

2460

1800

32.2

1275

DN

Lu

DN

e1

Lu

530

350

11.9

525

2690

2000

35

1295

80

8.1

85

275

80

8.1

100

8.4

85

275

80

95

275

85

1800

2000

32.2

35

Figure 26 Socket-Spigot Tees with Socket Branch


Table 26 Technical Parameters for Socket-Spigot Tees with Socket Branch
Body

125

150

200

250

194

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

8.7

9.1

9.8

10.5

Branch

Unit:mm

Body
Lu

DN

e1

Lu

85

295

590

400

12.6

530

8.1

95

320

610

450

13.3

535

100

8.4

95

350

600

500

14

535

280

80

8.1

105

410

660

600

15.4

535

95

290

100

8.4

110

470

720

700

16.8

535

110

295

125

8.7

110

520

815

800

18.2

550

85

275

80

8.1

120

585

835

900

19.6

575

100

280

100

8.4

120

120

420

80

8.1

550

115

305

125

8.7

120

130

435

100

8.4

560

130

310

150

9.1

125

145

445

125

8.7

560

90

275

80

8.1

145

155

465

150

9.1

570

100

280

100

8.4

145

180

495

200

9.8

570

115

305

125

8.7

145

210

525

250

10.5

570

130

310

150

9.1

150

240

545

300

11.2

575

160

340

200

9.8

155

265

575

350

11.9

575

90

300

80

8.1

170

295

600

400

12.6

580

100

280

100

8.4

170

320

620

450

13.3

585

Xinxing Ductile Iron Pipes Technical Manual

DN

900

1000

Branch

19.6

21

195

250

300

350

400

450

196

10.5

11.2

11.9

12.6

13.3

XINXING PIPES

300

525

450

13.3

290

595

895

900

19.6

710

585

100

320

80

8.1

295

650

950

1000

21

710

16.8

585

115

330

100

8.4

295

770

1070

1200

23.8

760

800

18.2

605

125

345

125

8.7

300

125

500

80

8.1

755

880

900

19.6

605

140

360

150

9.1

300

135

515

100

8.4

755

645

945

1000

21

635

165

390

200

9.8

300

150

525

125

8.7

760

225

120

435

80

8.1

600

195

395

250

10.5

310

165

540

150

9.1

765

9.1

200

130

450

100

8.4

600

225

425

300

11.2

315

195

570

200

9.8

765

200

9.8

205

145

460

125

8.7

600

255

455

350

11.9

315

220

600

250

10.5

765

370

250

10.5

210

155

480

150

9.1

600

285

485

400

12.6

315

240

630

300

11.2

770

220

400

300

11.2

220

185

510

200

9.8

605

300

525

450

13.3

315

265

655

350

11.9

770

90

300

80

8.1

215

215

540

250

10.5

605

340

540

500

14

325

295

680

400

12.6

770

100

310

100

8.4

215

245

560

300

11.2

605

90

325

80

8.1

345

325

700

450

13.3

770

120

325

125

8.7

215

270

590

350

11.9

610

100

330

100

8.4

345

355

735

500

14

770

125

340

150

9.1

215

300

615

400

12.6

610

125

345

125

8.7

350

410

790

600

15.4

775

160

340

200

9.8

220

320

635

450

13.3

610

130

360

150

9.1

350

470

845

700

16.8

785

190

370

250

10.5

235

345

665

500

14

615

160

390

200

9.8

350

525

905

800

18.2

815

220

400

300

11.2

235

405

725

600

15.4

620

190

415

250

10.5

360

600

900

900

19.6

815

250

430

350

11.9

235

415

715

700

16.8

630

230

430

300

11.2

365

660

960

1000

21

815

85

300

80

8.1

240

535

835

800

18.2

660

255

455

350

11.9

365

700

1065

1100

22.4

825

95

310

100

8.4

240

590

890

900

19.6

665

285

485

400

12.6

365

775

1075

1200

23.8

835

120

330

125

8.7

250

635

1060

1000

21

670

305

525

450

13.3

365

890

1190

1400

26.6

855

125

340

150

9.1

250

705

1005

1100

22.4

680

345

545

500

14

375

200

720

200

9.8

865

165

345

200

9.8

250

120

475

80

8.1

655

400

600

600

15.4

380

230

750

250

10.5

865

195

375

250

10.5

260

130

490

100

8.4

665

105

345

80

8.1

395

260

780

300

11.2

870

220

400

300

11.2

265

145

500

125

8.7

665

115

345

100

8.4

405

315

830

400

12.6

880

250

430

350

11.9

265

155

515

150

9.1

675

125

360

125

8.7

405

370

885

500

14

890

280

460

400

12.6

265

180

545

200

9.8

675

140

370

150

9.1

405

430

935

600

15.4

900

90

320

80

8.1

265

210

575

250

10.5

675

165

400

200

9.8

415

550

1050

800

18.2

925

100

330

100

8.4

265

240

605

300

11.2

680

195

430

250

10.5

415

660

1165

1000

21

945

125

345

125

8.7

275

265

630

350

11.9

685

230

480

300

11.2

415

780

1275

1200

23.8

965

130

360

150

9.1

275

295

655

400

12.6

685

260

510

350

11.9

420

985

1380

1400

26.6

1030

155

390

200

9.8

280

325

675

450

13.3

695

290

540

400

12.6

425

1010

1490

1600

29.4

1050

185

415

250

10.5

285

355

710

500

14

695

305

525

450

13.3

430

205

720

200

9.8

970

215

445

300

11.2

290

385

675

600

15.4

695

345

595

500

14

430

235

750

250

10.5

970

240

460

350

11.9

290

470

820

700

16.8

695

405

655

600

15.4

430

265

780

300

11.2

970

270

500

400

12.6

290

535

835

800

18.2

710

465

715

700

16.8

455

320

830

400

12.6

980

115

315

125

8.7

170

345

650

500

14

585

130

310

150

9.1

175

415

715

600

15.4

160

340

200

9.8

180

470

770

700

190

370

250

10.5

190

530

830

95

300

80

8.1

190

580

105

285

100

8.4

195

120

320

125

8.7

130

310

150

160

340

190

1000

1100

1200

21

22.4

23.8

Xinxing Ductile Iron Pipes Technical Manual

450

500

600

700

13.3

14

15.4

16.8

Xinxing Ductile Iron Pipes Technical Manual

1200

1400

1400

1600

1800

23.8

26.6

26.6

29.4

32.2

197

800

900

18.2

19.6

120

355

80

8.1

445

380

885

500

14

990

130

355

100

8.4

455

440

935

600

15.4

1000

145

370

125

8.7

455

550

1050

800

18.2

1025

155

380

150

9.1

460

650

1165

1000

21

1045

180

410

200

9.8

465

785

1275

1200

23.8

1065

210

440

250

10.5

465

850

1380

1400

26.6

1090

240

450

300

11.2

470

1000

1490

1600

29.4

1150

265

485

350

11.9

475

1100

1595

1800

32.2

1130

290

540

400

12.6

475

210

720

200

9.8

1080

320

535

450

13.3

485

240

750

250

10.5

1080

350

600

500

14

485

270

780

300

11.2

1080

410

660

600

15.4

485

325

830

400

12.6

1080

460

690

700

16.8

495

385

885

500

14

1090

525

775

800

18.2

515

440

935

600

15.4

1100

120

410

80

8.1

495

650

1050

800

18.2

1165

130

425

100

8.4

505

675

1165

1000

21

1185

145

435

125

8.7

505

880

1275

1200

23.8

1210

155

455

150

9.1

515

910

1380

1400

26.6

1230

180

485

200

9.8

520

1110

1490

1600

29.4

1250

210

515

250

10.5

520

1230

1595

1800

32.2

1275

240

535

300

11.2

525

1345

1705

2000

35

1295

265

565

350

11.9

525

1800

2000

32.2

35

(27)Socket-Spigot Tees with Flange Branch (Refer to Figure 27 and Table 27)

Figure 27 Socket-Spigot Tees with Flange Branch


Table 27 Technical Parameters for Socket-Spigot Tees with Flange Branch
Body
e

Lu

dn

e1

Lu

80

8.1

85

275

80

8.1

100

8.4

85

275

80

95

285

85

150

200

250

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Body

DN

125

198

Branch

8.7

9.1

9.8

10.5

Unit:mm

Lu

dn

e1

Lu

165

295

630

400

12.6

675

8.1

175

320

660

450

13.3

665

100

8.4

180

345

700

500

14

670

275

80

8.1

190

400

760

600

15.4

685

100

285

100

8.4

195

460

795

700

16.8

700

110

275

125

8.7

200

520

855

800

18.2

715

85

275

80

8.1

205

585

905

900

19.6

750

100

285

100

8.4

210

120

450

80

8.1

670

110

285

125

8.7

215

130

460

100

8.4

670

130

310

150

9.1

220

145

475

125

8.7

675

90

275

80

8.1

235

155

495

150

9.1

680

100

280

100

8.4

240

180

525

200

9.8

705

110

285

125

8.7

240

210

555

250

10.5

705

130

310

150

9.1

250

240

575

300

11.2

710

150

340

200

9.8

260

265

610

350

11.9

720

90

315

80

8.1

265

295

640

400

12.6

735

100

325

100

8.4

270

320

670

450

13.3

725

Xinxing Ductile Iron Pipes Technical Manual

DN

900

1000

Branch

19.6

21

199

250

300

350

400

450

200

10.5

11.2

11.9

12.6

13.3

XINXING PIPES

115

325

125

8.7

255

345

710

500

14

730

130

360

150

9.1

280

405

770

600

15.4

150

385

200

9.8

290

465

805

700

180

415

250

10.5

300

520

865

90

340

80

8.1

295

580

105

355

100

8.4

300

115

360

125

8.7

130

390

150

160

415

190

310

555

450

13.3

460

595

965

900

19.6

920

745

95

355

80

8.1

400

650

1030

1000

21

945

16.8

760

110

355

100

8.4

420

760

1145

1200

23.8

955

800

18.2

775

120

360

125

8.7

420

170

525

80

8.1

870

915

900

19.6

790

140

390

150

9.1

425

210

535

100

8.4

875

645

980

1000

21

825

165

415

200

9.8

440

225

550

125

8.7

880

285

120

465

80

8.1

730

190

445

250

10.5

440

240

570

150

9.1

880

9.1

310

130

475

100

8.4

730

220

475

300

11.2

440

270

595

200

9.8

890

200

9.8

320

145

490

125

8.7

735

245

500

350

11.9

450

280

625

250

10.5

895

445

250

10.5

330

155

510

150

9.1

740

280

530

400

12.6

480

325

655

300

11.2

905

215

475

300

11.2

340

180

540

200

9.8

745

300

555

450

13.3

480

355

685

350

11.9

910

95

345

80

8.1

325

210

570

250

10.5

755

340

580

500

14

500

385

715

400

12.6

920

100

355

100

8.4

330

240

590

300

11.2

760

100

355

80

8.1

460

415

745

450

13.3

925

115

360

125

8.7

315

265

625

350

11.9

770

100

355

100

8.4

460

440

785

500

14

935

135

390

150

9.1

340

300

655

400

12.6

795

120

360

125

8.7

465

515

845

600

15.4

980

160

415

200

9.8

350

325

685

450

13.3

795

130

390

150

9.1

470

560

880

700

16.8

990

190

445

250

10.5

350

350

725

500

14

795

170

415

200

9.8

500

630

940

800

18.2

1010

210

475

300

11.2

350

415

785

600

15.4

825

190

445

250

10.5

490

675

990

900

19.6

1020

240

500

350

11.9

380

470

820

700

16.8

830

215

475

300

11.2

500

750

1055

1000

21

1040

95

355

80

8.1

355

525

880

800

18.2

835

245

500

350

11.9

510

790

1105

1100

22.4

1045

105

355

100

8.4

360

585

930

900

19.6

850

285

530

400

12.6

540

850

1170

1200

23.8

1050

115

360

125

8.7

345

640

995

1000

21

870

305

555

450

13.3

530

85

275

80

8.1

165

135

390

150

9.1

370

695

1045

1100

22.4

880

335

580

500

14

540

225

755

100

8.4

1025

160

415

200

9.8

380

120

500

80

8.1

790

400

635

600

15.4

580

260

755

150

9.1

1025

190

445

250

10.5

390

130

510

100

8.4

790

105

345

80

8.1

490

290

730

200

9.8

1030

220

475

300

11.2

400

145

525

125

8.7

795

115

345

100

8.4

490

320

760

250

10.5

1040

240

500

350

11.9

400

155

545

150

9.1

800

125

361

125

8.7

495

345

790

300

11.2

1045

280

530

400

12.6

420

180

570

200

9.8

805

140

370

150

9.1

500

405

860

400

12.6

1060

95

355

80

8.1

370

210

600

250

10.5

815

170

385

200

9.8

525

520

915

600

15.4

1090

110

355

100

8.4

390

240

630

300

11.2

820

195

430

250

10.5

515

640

970

800

18.2

1120

115

360

125

8.7

405

265

660

350

11.9

830

220

440

300

11.2

520

750

1090

1000

21

1150

135

390

150

9.1

400

295

690

400

12.6

835

250

475

350

11.9

530

870

1210

1200

23.8

1180

165

415

200

9.8

410

325

720

450

13.3

845

285

495

400

12.6

555

985

1315

1400

26.6

1210

195

445

250

10.5

420

355

760

500

14

850

305

525

450

13.3

545

1100

1430

1600

29.4

1240

220

475

300

11.2

430

420

820

600

15.4

885

340

560

500

14

550

300

730

200

9.8

1150

240

500

350

11.9

440

470

855

700

16.8

885

385

595

600

15.4

565

320

760

250

10.5

1150

280

530

400

12.6

450

535

915

800

18.2

915

460

690

700

16.8

600

350

790

300

11.2

1155

1000

1100

1200

21

22.4

23.8

Xinxing Ductile Iron Pipes Technical Manual

450

500

600

700

13.3

14

15.4

16.8

Xinxing Ductile Iron Pipes Technical Manual

1200

1400

1600

1800

23.8

26.6

29.4

32.2

201

800

900

18.2

19.6

120

355

80

8.1

550

410

860

400

12.6

1170

130

355

100

8.4

550

470

915

500

14

1185

145

371

125

8.7

555

525

970

600

15.4

1200

155

381

150

9.1

560

640

1090

800

18.2

1230

175

395

200

9.8

585

760

1210

1000

21

1260

210

441

250

10.5

585

875

1315

1200

23.8

1290

240

451

300

11.2

585

990

1430

1400

26.6

1320

265

485

350

11.9

590

1110

1540

1600

29.4

1350

290

505

400

12.6

615

1225

1615

1800

32.2

1380

320

535

450

13.3

615

300

730

200

9.8

1250

345

571

500

14

615

330

760

250

10.5

1260

400

605

600

15.4

625

360

790

300

11.2

1265

460

700

700

16.8

640

415

860

400

12.6

1280

515

760

800

18.2

655

475

915

500

14

1295

120

440

80

8.1

605

530

970

600

15.4

1310

130

450

100

8.4

610

640

1090

800

18.2

1340

145

465

125

8.7

615

765

1210

1000

21

1370

155

485

150

9.1

620

880

1315

1200

23.8

1400

180

515

200

9.8

645

1000

1430

1400

26.6

1430

210

545

250

10.5

645

1110

1540

1600

29.4

1460

240

565

300

11.2

650

1230

1615

1800

32.2

1490

265

600

350

11.9

660

1345

1725

2000

35

1520

1800

2000

32.2

35

(28)Double-Socket Level Invert Tees with Flanged Branch (Refer to Figure 28 and Table 28)

Figure 28 Double-Socket Level Invert Tees with Flanged Branch

Table 28 Technical Parameters for Double-Socket Level Invert Tees with Flanged Branch
Body
e

dn

e1

100

8.4

170

80

8.1

175

150

9.1

170

80

8.1

210

195

100

8.4

175

80

200

250

300

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Body

DN

200

202

Branch

9.8

10.5

11.2

800

18.2

Branch
L

dn

e1

690

500

14

660

800

600

15.4

670

220

240

80

8.1

630

8.1

235

260

100

8.4

640

100

8.4

240

290

125

8.7

650

255

150

9.1

250

310

150

9.1

640

180

80

8.1

265

355

200

9.8

640

200

100

8.4

270

420

250

10.5

645

260

150

9.1

280

480

300

11.2

650

315

200

9.8

290

530

350

11.9

670

180

80

8.1

295

590

400

12.6

680

205

100

8.4

300

640

450

13.3

685

230

125

8.7

305

690

500

14

690

260

150

9.1

310

800

600

15.4

705

320

200

9.8

320

240

80

8.1

660

380

250

10.5

330

260

100

8.4

670

Xinxing Ductile Iron Pipes Technical Manual

DN

Unit:mm

900

1000

19.6

21

203

350

400

450

500

600

204

XINXING PIPES

11.9

12.6

13.3

14

15.4

185

80

8.1

325

290

125

8.7

680

340

200

9.8

500

480

150

9.1

910

205

100

8.4

330

310

150

9.1

700

380

250

10.5

510

540

200

9.8

920

230

125

8.7

335

360

200

9.8

700

430

300

11.2

520

560

250

10.5

925

270

150

9.1

340

420

250

10.5

705

490

350

11.9

530

650

300

11.2

935

325

200

9.8

350

480

300

11.2

710

570

400

12.6

540

710

350

11.9

940

385

250

10.5

360

530

350

11.9

720

610

450

13.3

550

770

400

12.6

945

420

300

11.2

370

595

400

12.6

730

670

500

14

560

830

450

13.3

955

185

80

8.1

355

640

450

13.3

745

210

80

8.1

520

880

500

14

965

210

100

8.4

360

690

500

14

750

230

100

8.4

540

1030

600

15.4

970

240

125

8.7

365

810

600

15.4

765

250

125

8.7

540

460

100

8.4

1015

270

150

9.1

370

240

80

8.1

740

280

150

9.1

550

580

200

9.8

1050

325

200

9.8

380

260

100

8.4

750

345

200

9.8

560

635

250

10.5

1060

385

250

10.5

390

290

125

8.7

760

390

250

10.5

570

695

300

11.2

1065

440

300

11.2

400

310

150

9.1

750

440

300

11.2

580

810

400

12.6

1080

480

350

11.9

410

360

200

9.8

750

500

350

11.9

590

925

500

14

1095

215

100

8.4

390

420

250

10.5

755

75

400

12.6

600

1040

600

15.4

1110

240

125

8.7

395

480

300

11.2

760

610

450

13.3

610

595

200

9.8

1260

270

150

9.1

400

530

350

11.9

765

680

500

14

620

650

250

10.5

1170

330

200

9.8

410

600

400

12.6

775

770

600

15.4

630

705

300

11.2

1175

390

250

10.5

420

650

450

13.3

805

240

80

8.1

580

820

400

12.6

1190

445

300

11.2

430

700

500

14

810

260

100

8.4

590

940

500

14

1205

480

350

11.9

440

830

600

15.4

825

290

125

8.7

590

1055

600

15.4

1220

560

400

12.6

450

240

80

8.1

820

310

150

9.1

600

600

200

9.8

1270

190

80

8.1

415

260

100

8.4

820

350

200

9.8

605

660

250

10.5

1280

215

100

8.4

420

290

125

8.7

825

420

250

10.5

610

720

300

11.2

1290

240

125

8.7

425

310

150

9.1

830

480

300

11.2

620

835

400

12.6

1310

280

150

9.1

430

360

200

9.8

840

530

350

11.9

630

950

500

14

1325

330

200

9.8

440

420

250

10.5

850

580

400

12.6

640

1065

600

15.4

1330

380

250

10.5

450

480

300

11.2

860

640

450

13.3

650

440

300

11.2

460

530

350

11.9

870

490

350

11.9

470

590

400

12.6

880

565

400

12.6

480

650

450

13.3

890

600

450

13.3

490

710

500

14

870

195

80

8.1

475

840

600

15.4

885

200

100

8.4

480

340

80

8.1

905

240

125

8.7

485

420

100

8.4

905

260

150

9.1

490

450

125

8.7

910

1000

1100

1200

1400

21

22.4

23.8

26.6

Xinxing Ductile Iron Pipes Technical Manual

600

700

800

15.4

16.8

18.2

Xinxing Ductile Iron Pipes Technical Manual

1400

1600

1800

2000

26.6

29.4

32.2

35

205

(29)All Socket Level Invert Tees (Refer to Figure 29 and Table 29)
300

350

400

11.2

11.9

12.6

Figure 29 All Socket Level Invert Tees

Table 29 Technical Parameters for All Socket Level Invert Tees

Body

Body

DN

dn

e1

100

8.4

170

80

8.1

100

125

8.7

170

80

8.1

110

195

100

8.4

115

170

80

8.1

195

100

230

150

200

250

300

206

Branch

XINXING PIPES

9.1

9.8

10.5

11.2

Unit:mm

DN

150

9.1

180

240

80

8.1

535

320

200

9.8

185

260

100

8.4

540

375

250

10.5

215

290

125

8.7

540

180

80

8.1

200

310

150

9.1

545

200

100

8.4

200

360

200

9.8

550

250

150

9.1

205

420

250

10.5

555

300

200

9.8

210

480

300

11.2

560

360

250

10.5

240

530

350

11.9

565

420

300

11.2

265

590

400

12.6

570

170

80

8.1

225

640

450

13.3

575

190

100

8.4

225

690

500

14

580

220

125

8.7

250

800

600

15.4

590

250

150

9.1

230

230

80

8.1

595

310

200

9.8

235

260

100

8.4

600

360

250

10.5

245

280

125

8.7

605

420

300

11.2

270

310

150

9.1

610

480

350

11.9

295

370

200

9.8

610

180

80

8.1

250

430

250

10.5

615

200

100

8.4

250

490

300

11.2

620

225

125

8.7

255

540

350

11.9

625

260

150

9.1

255

600

400

12.6

630

310

200

9.8

260

640

450

13.3

630

1000

1100

21

22.4

dn

e1

590

400

12.6

470

640

450

13.3

475

370

250

10.5

270

690

500

14

635

690

500

14

480

430

300

11.2

275

810

600

15.4

640

120

800

600

15.4

495

480

350

11.9

300

240

80

8.1

635

8.4

120

240

80

8.1

485

540

400

12.6

325

260

100

8.4

640

125

8.7

130

260

100

8.4

490

200

80

8.1

275

290

125

8.7

640

175

80

8.1

125

290

125

8.7

490

230

100

8.4

275

310

150

9.1

645

200

100

8.4

125

310

150

9.1

495

225

125

8.7

275

360

200

9.8

650

255

150

9.1

130

360

200

9.8

500

280

150

9.1

280

420

250

10.5

655

180

80

8.1

150

420

250

10.5

505

330

200

9.8

285

480

300

11.2

660

200

100

8.4

150

480

300

11.2

510

380

250

10.5

295

530

350

11.9

665

260

150

9.1

155

530

350

11.9

515

440

300

11.2

300

590

400

12.6

670

315

200

9.8

160

590

400

12.6

520

490

350

11.9

305

650

450

13.3

675

190

80

8.1

175

640

450

13.3

525

540

400

12.6

330

710

500

14

680

205

100

8.4

175

690

500

14

530

600

450

13.3

355

820

600

15.4

695

215

125

8.7

200

800

600

15.4

545

180

80

8.1

325

250

80

8.1

745

800

900

Branch

260

18.2

19.6

Xinxing Ductile Iron Pipes Technical Manual

450

500

600

13.3

14

15.4

Xinxing Ductile Iron Pipes Technical Manual

1200

1400

23.8

26.6

207

600

700

800

15.4

16.8

18.2

(30)Socket Spigot Level Invert Tees with Flanged Branch (Refer to Figure 30 and Table 30)

200

100

8.4

325

270

100

8.4

745

230

125

8.7

325

300

125

8.7

755

260

150

9.1

330

330

150

9.1

755

320

200

9.8

335

390

200

9.8

760

380

250

10.5

345

440

250

10.5

765

430

300

11.2

350

490

300

11.2

770

490

350

11.9

355

530

350

11.9

775

550

400

12.6

360

590

400

12.6

780

610

450

13.3

385

650

450

13.3

785

670

500

14

390

700

500

14

790

210

80

8.1

385

820

600

15.4

800

230

100

8.4

390

1520

1200

23.8

870

250

125

8.7

390

400

200

9.8

885

280

150

9.1

395

455

250

10.5

885

330

200

9.8

400

515

300

11.2

890

390

250

10.5

405

630

400

12.6

900

440

300

11.2

410

745

500

14

910

500

350

11.9

415

860

600

15.4

920

560

400

12.6

420

410

200

9.8

990

610

450

13.3

425

470

250

10.5

990

680

500

14

430

530

300

11.2

990

770

600

15.4

445

640

400

12.6

1000

DN

Lu

dn

e1

Lu

240

80

8.1

435

760

500

14

1010

100

8.4

85

275

80

8.1

175

260

100

8.4

440

875

600

15.4

1020

275

80

8.1

210

125

8.7

440

420

200

9.8

1100

9.1

85

290

150

100

285

100

8.4

310

150

9.1

445

480

250

10.5

1100

90

275

80

360

200

9.8

450

540

300

11.2

1100

100

280

420

250

10.5

455

650

400

12.6

1100

130

480

300

11.2

460

770

500

14

1110

530

350

11.9

465

885

600

15.4

1120

1400

1600

1800

2000

26.6

29.4

32.2

35

Figure 30 Socket Spigot Level Invert Tees with Flanged Branch

able 30 Technical Parameters for Socket Spigot Level Invert Tees with Flanged Branch
Body

200

250

300

208

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

9.8

10.5

11.2

Branch

Unit:mm

Body
Lu

dn

e1

320

535

450

13.3

650

345

571

500

14

660

220

400

605

600

15.4

670

8.1

235

120

440

80

8.1

640

100

8.4

240

130

450

100

8.4

640

310

150

9.1

250

145

465

125

8.7

640

90

315

80

8.1

265

155

485

150

9.1

640

100

325

100

8.4

270

180

515

200

9.8

645

130

360

150

9.1

280

210

545

250

10.5

650

160

385

200

9.8

290

240

565

300

11.2

660

90

340

80

8.1

295

265

600

350

11.9

670

105

355

100

8.4

295

295

630

400

12.6

680

130

390

150

9.1

310

320

660

450

13.3

685

150

415

200

9.8

320

345

700

500

14

690

190

445

250

10.5

330

400

760

600

15.4

705

Xinxing Ductile Iron Pipes Technical Manual

DN

800

900

Branch

18.2

19.6

209

350

400

450

500

600

210

11.9

12.6

13.3

14

15.4

XINXING PIPES

95

345

80

8.1

325

120

450

80

8.1

680

130

390

150

9.1

490

210

535

100

8.4

910

100

355

100

8.4

330

130

460

100

8.4

700

170

415

200

9.8

500

225

550

125

8.7

920

115

360

125

8.7

335

145

475

125

8.7

700

190

445

250

10.5

510

240

570

150

9.1

925

135

390

150

9.1

340

155

495

150

9.1

705

215

475

300

11.2

520

270

595

200

9.8

935

160

415

200

9.8

350

180

525

200

9.8

710

245

500

350

11.9

530

280

625

250

10.5

940

190

445

250

10.5

360

210

555

250

10.5

720

285

530

400

12.6

540

325

655

300

11.2

945

210

475

300

11.2

370

240

575

300

11.2

730

305

555

450

13.3

550

355

685

350

11.9

955

95

355

80

8.1

355

265

610

350

11.9

740

335

580

500

14

560

385

715

400

12.6

965

105

355

100

8.4

360

295

640

400

12.6

750

105

345

80

8.1

520

415

745

450

13.3

975

115

360

125

8.7

365

320

670

450

13.3

750

115

345

100

8.4

540

440

785

500

14

985

135

390

150

9.1

370

345

710

500

14

750

125

361

125

8.7

540

500

845

600

15.4

990

160

415

200

9.8

380

405

770

600

15.4

765

140

370

150

9.1

550

290

730

200

9.8

1050

190

445

250

10.5

390

120

465

80

8.1

750

170

385

200

9.8

560

320

760

250

10.5

1060

220

475

300

11.2

400

130

475

100

8.4

750

195

430

250

10.5

570

345

790

300

11.2

1065

240

500

350

11.9

410

145

490

125

8.7

750

220

440

300

11.2

580

405

860

400

12.6

1080

95

355

80

8.1

385

155

510

150

9.1

755

250

475

350

11.9

590

465

895

500

14

1095

110

355

100

8.4

390

180

540

200

9.8

760

285

495

400

12.6

600

520

915

600

15.4

1110

115

360

125

8.7

395

210

570

250

10.5

765

305

525

450

13.3

610

300

730

200

9.8

1170

135

390

150

9.1

400

240

590

300

11.2

775

340

560

500

14

620

320

760

250

10.5

1170

165

415

200

9.8

410

265

625

350

11.9

820

385

595

600

15.4

630

350

790

300

11.2

1175

195

445

250

10.5

420

295

655

400

12.6

820

120

355

80

8.1

580

410

860

400

12.6

1190

220

475

300

11.2

430

325

685

450

13.3

805

130

355

100

8.4

580

470

915

500

14

1205

240

500

350

11.9

440

350

725

500

14

810

145

371

125

8.7

600

525

970

600

15.4

1220

280

530

400

12.6

450

410

785

600

15.4

825

155

381

150

9.1

605

300

730

200

9.8

1270

95

355

80

8.1

415

120

500

80

8.1

825

180

395

200

9.8

610

330

760

250

10.5

1280

110

355

100

8.4

420

130

510

100

8.4

830

210

441

250

10.5

620

360

790

300

11.2

1290

120

360

125

8.7

425

145

525

125

8.7

840

240

451

300

11.2

630

415

860

400

12.6

1310

140

390

150

9.1

430

155

545

150

9.1

850

265

485

350

11.9

630

475

915

500

14

1325

165

415

200

9.8

440

180

570

200

9.8

860

295

505

400

12.6

640

530

970

600

15.4

1330

190

445

250

10.5

450

210

600

250

10.5

870

220

475

300

11.2

460

240

630

300

11.2

880

245

500

350

11.9

470

265

660

350

11.9

890

280

530

400

12.6

480

295

690

400

12.6

905

300

555

450

13.3

490

325

720

450

13.3

905

100

355

80

8.1

475

355

760

500

14

910

100

355

100

8.4

480

410

820

600

15.4

910

120

360

125

8.7

485

170

525

80

8.1

910

1000

1100

1200

1400

21

22.4

23.8

26.6

Xinxing Ductile Iron Pipes Technical Manual

600

700

800

15.4

16.8

18.2

Xinxing Ductile Iron Pipes Technical Manual

1400

1600

1800

2000

26.6

29.4

32.2

35

211

(31)All Socket Eccentric Tees 45 (Refer to Figure 31 and Table 31)

250

300

350

Figure 31 All Socket Eccentric Tees 45

Table 31 Technical Parameters for All Socket Eccentric Tees 45

DN

dn

80

80

100

size
L

8.1

8.1

240

85

100

8.4

630

105

8.1

265

85

125

8.7

630

120

8.4

265

95

150

9.1

635

135

8.1

295

85

9.8

640

165

8.4

300

100

10.5

645

190

125

8.7

300

115

300

11.2

650

220

80

8.1

325

85

350

11.9

660

250

8.4

330

100

400

12.6

665

280

8.7

330

115

100

8.4

690

105

150

9.1

335

125

150

9.1

695

135

80

8.1

385

90

200

9.8

700

165

100

8.4

390

100

10.5

705

195

8.7

390

115

11.2

710

225

150

9.1

395

130

350

11.9

720

250

200

9.8

400

160

400

12.6

725

280

8.1

445

90

450

13.3

730

310

8.4

80
125

150

200

250

212

XINXING PIPES

100

100
125

125

80

8.7

9.1

9.8

10.5

400

450

200
250

250
300

8.4

450

100

100

8.4

750

110

125

8.7

450

115

150

9.1

755

140

9.1

455

130

200

9.8

760

145

200

9.8

460

160

250

10.5

770

195

250

10.5

465

190

11.2

775

225

80

8.1

505

90

350

11.9

780

255

100

8.4

510

100

400

12.6

785

280

125

8.7

510

115

450

13.3

790

310

9.1

515

130

500

14

795

340

200

9.8

520

160

100

8.4

870

110

250

10.5

525

190

150

9.1

880

140

300

11.2

530

220

200

9.8

885

170

100

8.4

570

105

250

10.5

890

200

125

8.7

570

120

11.2

895

225

150

9.1

575

135

11.9

900

255

9.8

580

160

400

12.6

905

285

250

10.5

585

190

450

13.3

910

315

300

11.2

590

220

500

14

915

345

350

11.9

595

250

600

15.4

930

400

150

150

200

10.5

11.2

11.9

500

600

300

300
350

14

15.4

size
L

100

e1

dn

e1

80

DN

Unit:mm

100

12.6

13.3

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

213

(32)All Flanged Eccentric Tees 45 (Refer to Figure 32 and Table 32))

200

250

300

Figure 32 All Flanged Eccentric Tees 45


350
Table 32 Technical Parameters for All Flanged Eccentric Tees 45

DN

dn

80

80

100

size
h

8.1

8.1

390

85

8.1

415

8.4

150

200

100

8.4

780

105

85

125

8.7

780

120

415

95

150

9.1

785

135

8.1

445

85

9.8

790

165

8.4

445

95

10.5

795

190

125

8.7

450

110

300

11.2

800

220

80

8.1

475

85

350

11.9

810

250

8.4

480

100

400

12.6

815

280

8.7

480

115

100

8.4

840

105

150

9.1

485

125

150

9.1

845

135

80

8.1

535

90

9.8

850

165

8.4

540

100

10.5

855

195

8.7

540

115

300

11.2

865

225

9.1

545

130

350

11.9

870

250

100

100
125

100
125
150

214

XINXING PIPES

dn

8.4

80
125

DN

100

e1

size
e1

80

Unit:mm

8.7

9.1

9.8

400

450

200
250

200
250

12.6

13.3

Xinxing Ductile Iron Pipes Technical Manual

200

9.8

550

160

12.6

875

280

80

8.1

595

90

13.3

880

310

100

8.4

600

100

100

8.4

900

110

8.7

600

115

150

9.1

915

140

9.1

605

130

200

9.8

915

165

200

9.8

610

160

250

10.5

920

195

250

10.5

615

190

11.2

925

225

80

8.1

655

90

350

11.9

930

245

100

8.4

660

100

400

12.6

935

280

125

8.7

660

115

450

13.3

940

310

9.1

665

130

500

14

945

340

200

9.8

670

160

100

8.4

1020

110

250

10.5

675

190

150

9.1

1030

140

300

11.2

680

220

200

9.8

1035

170

100

8.4

720

105

250

10.5

1040

200

125

8.7

720

120

11.2

1045

225

150

9.1

725

135

11.9

1050

255

9.8

730

160

400

12.6

1055

285

250

10.5

735

190

450

13.3

1060

315

300

11.2

740

220

500

14

1065

345

350

11.9

745

250

600

15.4

1080

400

125
150

150

200

9.8

10.5

11.2

11.9

Xinxing Ductile Iron Pipes Technical Manual

450

500

600

400
450

300

300
350

13.3

14

15.4

215

(33)All Socket Crosses (Refer to Figure 33 and Table 33)

250

300

10.5

11.2

Figure 33 All Socket Crosses


350

Table 33 Technical Parameters for All Socket Crosses


Body
e

dn

e1

80

8.1

85

80

8.1

100

8.4

85

80

95

150

200

XINXING PIPES

8.7

9.1

9.8

Unit:mm

Body

DN

125

216

Branch
DN

Branch
L

dn

e1

85

155

200

9.8

250

8.1

95

180

250

10.5

260

100

8.4

95

210

300

11.2

265

85

80

8.1

105

240

350

11.9

265

95

100

8.4

110

270

400

12.6

270

110

125

8.7

110

90

80

8.1

265

85

80

8.1

120

100

100

8.4

265

100

100

8.4

120

125

125

8.7

265

115

125

8.7

120

130

150

9.1

265

130

150

9.1

125

155

200

9.8

270

90

80

8.1

145

185

250

10.5

285

100

100

8.4

145

215

300

11.2

290

115

125

8.7

145

240

350

11.9

290

130

150

9.1

150

270

400

12.6

290

160

200

9.8

155

300

450

13.3

300

400

450

12.6

13.3

11.9

Xinxing Ductile Iron Pipes Technical Manual

400

12.6

90

80

8.1

170

100

80

8.1

295

100

100

8.4

170

115

100

8.4

295

115

125

8.7

170

125

125

8.7

295

130

150

9.1

175

140

150

9.1

295

160

200

9.8

180

165

200

9.8

300

190

250

10.5

190

190

250

10.5

310

95

80

8.1

190

220

300

11.2

315

105

100

8.4

195

245

350

11.9

315

120

125

8.7

225

270

400

12.6

315

130

150

9.1

200

300

450

13.3

315

160

200

9.8

205

330

500

14

330

190

250

10.5

210

90

80

8.1

345

220

300

11.2

220

100

100

8.4

345

90

80

8.1

215

125

125

8.7

345

100

100

8.4

215

130

150

9.1

345

125

150

9.1

215

160

200

9.8

350

150

200

9.8

220

190

250

10.5

360

180

250

10.5

235

215

300

11.2

365

210

300

11.2

235

245

350

11.9

365

240

350

11.9

240

275

400

12.6

365

85

80

8.1

240

305

450

13.3

365

95

100

8.4

240

335

500

14

375

120

125

8.7

250

390

600

15.4

390

125

150

9.1

250

Xinxing Ductile Iron Pipes Technical Manual

500

600

14

15.4

217

(34)All Flanged Crosses (Refer to Figure 34 and Table 34)

250

300

350

10.5

11.2

11.9

Figure 34 All Flanged Crosses

Table 34 Technical Parameters for All Flanged Crosses


Body

Body

DN

dn

e1

80

8.1

165

80

8.1

100

8.4

165

80

180

125

150

200

250

218

Branch

XINXING PIPES

8.7

9.1

9.8

10.5

Unit:mm

DN

Branch
L

dn

e1

165

235

150

9.1

355

8.1

175

450

200

9.8

350

100

8.4

180

250

250

10.5

345

200

80

8.1

190

275

300

11.2

370

200

100

8.4

195

450

350

11.9

360

200

125

8.7

200

330

400

12.6

390

220

80

8.1

205

360

100

8.4

400

220

100

8.4

210

380

125

8.7

390

220

125

8.7

215

450

150

9.1

450

220

150

9.1

220

235

200

9.8

370

260

80

8.1

235

475

250

10.5

375

260

100

8.4

240

265

300

11.2

375

220

125

8.7

240

285

350

11.9

400

260

150

9.1

250

475

400

12.6

375

260

200

9.8

260

345

450

13.3

420

200

80

8.1

265

370

100

8.4

430

400

450

500

400

12.6

13.3

14

Xinxing Ductile Iron Pipes Technical Manual

12.6

350

100

8.4

275

395

125

8.7

420

240

125

8.7

280

430

150

9.1

450

240

150

9.1

280

475

200

9.8

475

350

200

9.8

325

500

250

10.5

400

350

250

10.5

350

500

300

11.2

400

210

100

8.4

295

500

350

11.9

400

400

125

8.7

300

500

400

12.6

400

240

150

9.1

300

500

450

13.3

400

250

200

9.8

310

500

500

14

400

400

250

10.5

350

500

100

8.4

500

310

300

11.2

330

500

125

8.7

500

400

100

8.4

400

500

150

9.1

500

220

125

8.7

325

500

200

9.8

500

425

150

9.1

325

500

250

10.5

500

240

200

9.8

325

550

300

11.2

450

265

250

10.5

340

550

350

11.9

450

425

300

11.2

325

550

400

12.6

450

320

350

11.9

360

550

450

13.3

450

340

100

8.4

350

550

500

14

450

425

125

8.7

425

550

600

15.4

450

Xinxing Ductile Iron Pipes Technical Manual

500

600

14

15.4

219

(35)Socket Spigot Crosses with Double Socket (Refer to Figure 35 and Table 35)
300

400

500

11.2

12.6

14

Figure 35 Socket Spigot Crosses with Double Socket

Table 35 Technical Parameters for Socket Spigot Crosses with Double Socket

340

200

9.8

205

190

370

250

10.5

210

220

400

300

11.2

220

110

290

100

8.4

245

135

315

150

9.1

250

165

345

200

9.8

255

195

375

250

10.5

260

220

400

300

11.2

270

280

460

400

12.6

280

110

310

100

8.4

290

135

335

150

9.1

295

165

365

200

9.8

300

195

395

250

10.5

315

225

425

300

11.2

320

285

485

400

12.6

330

340

540

500

14

340

110

315

100

8.4

350

135

340

150

9.1

355

165

370

200

9.8

360

195

400

250

10.5

365

230

430

300

11.2

370

DN

e1

dn

e2

80

8.1

85

260

80

8.1

85

100

8.4

85

270

80

8.1

95

285

485

400

12.6

380

95

275

100

8.4

95

345

545

500

14

390

85

280

80

8.1

120

400

600

600

15.4

400

100

280

100

8.4

120

130

310

150

9.1

125

90

280

80

8.1

145

100

280

100

8.4

145

130

310

150

9.1

150

160

340

200

9.8

155

90

280

80

8.1

170

100

280

100

8.4

170

130

310

150

9.1

175

160

340

200

9.8

180

190

370

250

10.5

190

105

285

100

8.4

195

130

310

150

9.1

200

150

200

250

300

220

Unit:mm

160

XINXING PIPES

9.1

9.8

10.5

11.2

Xinxing Ductile Iron Pipes Technical Manual

600

15.4

Xinxing Ductile Iron Pipes Technical Manual

221

(36)T-Type Spigot Cap (Refer to Figure 36 and Table 36)

(37)T-Type Socket Plugs (Refer to Figure 36 and Table 36)

(a)DN300

(b)DN 300

(a)DN300

(b)DN 300
Figure 37 T-Type Socket Plugs

Figure 36 T-Type Spigot Cap

Table 36 Technical Parameters for T-Type Spigot Cap

222

Table 37 Technical Parameters for T-Type Socket Plugs


Unit:mm

Unit:mm

DN

DE

e1

K.R

80

98

16

190

100

118

18

7.2

200

125

144

18

7.5

212

150

170

18

7.8

225

200

222

18

7.2

250

250

274

19.5

9.0

250

300

326

23

9.6

275

350

378

24

10.2

315

275

DN

DN

80

18

600

29.5

565

100

18

700

31

665

125

18

800

33

760

150

18

900

35

860

200

18

1000

37

960

250

19.5

1100

39

1060

400

429

25

10.8

370

275

300

23

1200

41

1160

450

480

26

11.4

420

275

350

24

315

1400

43

1260

500

532

27

12

460

275

400

25

370

1500

44

2362

600

635

29.5

13.2

565

300

450

26

420

1600

45

2715

700

738

30

14.4

660

320

500

27

460

1800

48

3186

800

842

30

15.6

760

330

900

945

30

16.8

860

350

1000

1048

35

18

960

360

1100

1152

35

19.2

1060

380

1200

1255

35

20.4

1160

390

1400

1462

40

22.8

1260

410

1500

1565

40

24

1360

420

1600

1668

40

25.2

1460

450

1800

1875

45

27.6

1560

480

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

223

(38)Flexible Couplings (Refer to Figure 38 and Table 38)

(39)Flange Adaptors (Refer to Figure 39 and Table 39)

Figure 38 Flexible Couplings

Figure 39 Flange Adaptors

Table 38 Technical Parameters for Flexible Couplings

DN

224

Unit:mm

Table 39 Technical Parameters for Flange Adaptors

size

Bolts

DN

t1

d1

Unit:mm

No. of Bolts/n

Sizes of Bolts/ DIA

PN10

PN16

PN25

PN10

PN16

PN25

PN10

PN16

PN25

70

160

160

160

M16

M16

M16

100

70

180

180

190

M16

M16

M20

M20

150

75

240

240

250

M20

M20

M24

M20

200

75

295

295

310

M20

M20

M24

15

M24

250

90

350

355

370

M20

M24

M27

50

15

M24

300

90

400

410

430

M20

M24

M27

134

50

20

M24

350

100

460

470

490

M20

M24

M30

429

134

50

20

M27

400

100

515

525

550

M24

M27

M33

450

480

134

50

20

10

M27

450

100

565

585

600

10

10

10

M24

M27

M33

500

532

154

55

25

10

M30

500

114

620

650

660

10

10

10

M24

M30

M33

600

635

174

60

25

10

M33

600

114

725

770

770

10

10

10

M27

M33

M36

700

738

184

70

30

12

M33

700

130

840

840

875

12

12

12

M27

M33

M39

800

842

184

70

30

12

M36

800

130

950

950

990

12

12

12

M30

M36

M45

900

945

214

85

30

14

M36

900

130

1050

1050

1050

14

14

14

M30

M36

M45

1000

1048

244

92

30

14

M39

1000

130

1160

1170

1160

14

14

14

M33

M39

M52

1200

1255

274

107

30

16

M45

1200

130

1380

1390

1380

16

16

16

M36

M45

M52

1400

1462

360

96

15

18

M24

1400

150

1590

1590

1640

18

18

18

M39

M45

M56

1500

1565

470

118

25

18

M52

1500

170

1700

1710

18

18

M39

M52

1600

1668

485

120

30

20

M45

1600

180

1820

1820

20

20

M45

M52

d1

DIA

80

98

96

40

15

M16

80

100

118

96

40

15

M16

150

170

96

40

15

200

222

96

46

15

250

274

116

50

300

326

116

350

378

400

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

225

(40)Dismantling Joints (Refer to Figure 40 and Table 40)

(41)Flange Bellmouthes (Refer to Figure 41 and Table 41)

Figure 40 Dismantling Joints

Table 40 Technical Parameters for Dismantling Joints

Unit:mm

Table 41 Technical Parameters for Flange Bellmouthes

Unit:mm

DN

DN

PN10

PN16

PN25

PN40

80

170

120

800

980

380

80

200

200

210

210

100

190

130

900

1095

415

100

200

200

220

220

150

260

150

1000

1210

450

150

200

200

230

230

200

300

180

1200

1440

520

200

220

220

230

240

250

350

200

1400

1670

590

250

220

230

250

260

300

420

250

1600

1900

660

300

220

250

250

280

350

550

250

1800

2130

730

350

230

260

270

290

400

550

250

2000

2360

800

400

230

270

280

340

450

620

260

2200

2588

800

450

250

270

280

340

500

680

300

2400

2756

800

500

260

280

300

380

600

780

300

2600

3000

900

600

260

300

320

390

700

865

345

700

335

335

335

800

335

335

335

900

355

355

355

1000

355

355

355

1200

375

375

375

1400

380

380

1500

450

450

1600

450

450

DN

226

Figure 41 Flange Bellmouthes

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

227

(42)Flange

1400

1675

1590

1530

1462

46

32

20

43

M39

36

1500

1786

1700

1640

1565

47.5

33

20

43

M39

36

1600

1915

1820

1750

1668

49

34.5

20

49

M45

40

1800

2115

2020

1950

1875

52

36.5

20

49

M45

44

2000

2325

2230

2150

2082

55

38.5

20

49

M45

48

PN16 (Refer to Figure 42and Table 43)

Table 43 Technical Parameters for Flange PN16

Figure 40 Dismantling Joint

PN10 (Refer to Figure 42 and Table 42)


Table 42 Technical Parameters for Flange PN10

228

DN

D1

D2

D3

DE

80

200

160

132

98

19

15

100

220

180

156

118

19

150

285

240

211

170

19

200

340

295

266

222

250

400

350

319

300

455

400

350

505

400

Unit:mm
bolt holes
d

Specification

19

M16

15

19

M16

15

23

M20

20

16

23

M20

274

22

17.5

10

23

M20

12

370

326

24.5

19.5

10

23

M20

12

460

429

378

24.5

19.5

10

23

M20

16

565

515

480

429

24.5

19.5

10

28

M24

16

450

615

565

530

480

24.5

20.5

12

28

M24

20

500

670

620

582

532

26.5

21

12

28

M24

20

600

780

725

682

635

30

24

12

31

M27

20

700

895

840

794

738

32.5

23

16

31

M27

24

800

1015

950

901

842

35

24.5

16

34

M30

24

900

1115

1050

1001

945

37.5

26.5

16

34

M30

28

1000

1230

1160

1112

1048

40

28

16

37

M33

28

1100

1340

1270

1218

1152

42.5

30

20

37

M33

32

1200

1455

1380

1328

1255

45

31.5

20

40

M36

32

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

DN

D1

D2

D3

DE

80

200

160

132

98

19

15

100

220

180

156

118

19

150

285

240

211

170

19

200

340

295

266

222

250

400

355

319

300

455

410

350

520

400

Unit:mm
bolt holes
d

Specification

19

M16

15

19

M16

15

23

M20

20

16

23

M20

12

274

22

17.5

10

28

M24

12

370

326

24.5

19.5

10

28

M24

12

470

429

378

26.5

21

10

28

M24

16

580

525

480

429

28

22.5

10

31

M27

16

450

640

585

548

480

30

24

12

31

M27

20

500

715

650

609

532

31.5

25

12

34

M30

20

600

840

770

720

635

36

29

12

37

M33

20

700

910

840

794

738

39.5

27.5

16

37

M33

24

800

1025

950

901

842

43

30

16

40

M36

24

900

1125

1050

1001

945

46.5

32.5

16

40

M36

28

1000

1255

1170

1112

1048

50

35

16

43

M39

28

1100

1355

1270

1218

1152

53.5

37.5

20

43

M39

32

1200

1485

1390

1328

1255

57

40

20

49

M45

32

1400

1685

1590

1530

1462

60

42

20

49

M45

36

1500

1820

1710

1640

1565

62.5

43

20

56

M52

36

1600

1930

1820

1750

1668

65

45.5

20

56

M52

40

1800

2130

2020

1950

1875

70

49

20

56

M52

44

2000

2345

2230

2150

2082

75

52.5

20

62

M56

48

Xinxing Ductile Iron Pipes Technical Manual

229

PN25 (Refer to Figure 42 and Table 44)

PN40 (Refer to Figure 42 and Table 45)

Table 44 Technical Parameters for Flange PN25

DN

D1

D2

D3

DE

80

200

160

132

98

19

15

100

235

190

156

118

19

150

300

250

211

170

20

200

360

310

274

222

250

425

370

330

300

485

430

350

555

400

Table 45 Technical Parameters for PN40

Unit:mm

bolt holes
d

Specification

19

M16

15

23

M20

16

28

M24

22

17.5

28

M24

12

274

24.5

19.5

10

31

M27

12

389

326

27.5

22

10

31

M27

16

490

448

378

30

24

10

34

M30

16

620

550

503

429

32

25.5

10

37

M33

16

450

670

600

548

480

34.5

27.5

12

37

M33

20

500

730

660

609

532

36.5

29

12

37

M33

20

600

845

770

720

635

42

33.5

12

40

M36

20

700

960

875

820

738

46.5

32.5

16

43

M39

24

800

1085

990

928

842

51

35.5

16

49

M45

24

900

1185

1090

1028

945

55.5

39

16

49

M45

28

1000

1320

1210

1140

1048

60

42

16

56

M52

28

1100

1420

1310

1240

1152

64.5

45

20

56

M52

32

1200

1530

1420

1350

1255

69

48.5

20

56

M52

32

1400

1755

1640

1560

1462

74

52

20

62

M56

36

1600

1975

1860

1780

1668

81

56.5

20

62

M56

40

1800

2195

2070

1985

1875

88

61.5

20

70

M64

44

2000

2425

2300

2210

2082

95

66.5

20

70

M64

48

DN

D1

D2

D3

DE

80

200

160

132

98

19

15

100

235

190

156

118

19

150

300

250

211

170

26

200

375

320

284

222

250

450

385

345

300

515

450

350

580

400

Unit:mm
bolt holes
d

Specification

19

M16

15

23

M20

18

28

M24

30

21

31

M27

12

274

34.5

24

10

34

M30

12

409

326

39.5

27.5

10

34

M30

16

510

465

378

44

31

10

37

M33

16

660

585

535

429

48

33.5

10

40

M36

16

450

685

610

560

480

50

35

12

40

M36

20

500

755

670

615

532

52

36.5

12

43

M39

20

600

890

795

735

635

58

40.5

12

49

M45

20

(43)Welded-on Flange

Figure 43 Welded-on Flange

230

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

231

PN10 (Refer to Figure 43 and Table 46)

PN16 (Refer to Figure 43 and Table 47)

Table 46 Technical Parameters for Welded-on Flange PN10

232

Unit:mm

Table 47 Technical Parameters for Welded-on Flange PN16

Unit:mm

DN

D1

D2

D3

D4

D5

D6

DN

D1

D2

D3

D4

D5

D6

80

220

160

132

98

112

118

19

19

50

80

220

160

132

98

112

118

19

19

50

100

220

180

156

118

133

139

19

19

60

100

220

180

156

118

133

139

19

19

60

125

250

210

170

144

158

164

19

19

60

125

250

210

170

144

158

164

19

19

60

150

285

240

211

170

186

192

19

23

60

150

285

240

211

170

186

192

19

23

60

200

340

295

266

222

240

246

20

23

64

200

340

295

266

222

240

246

20

23

12

64

250

400

350

319

274

294

300

22

23

12

10

64

250

400

355

319

274

294

300

22

28

12

10

64

300

455

400

370

326

346

352

24.5

23

12

10

74

300

455

410

370

326

346

352

24.5

28

12

10

74

350

505

460

429

378

400

408

24.5

23

16

10

74

350

520

470

429

378

400

408

26.5

28

16

10

74

400

565

515

480

429

451

459

24.5

28

16

10

80

400

580

525

480

429

451

459

28

31

16

10

80

450

615

565

530

480

500

506

24.5

28

20

12

80

450

640

585

548

480

500

506

30

31

20

12

86

500

670

620

582

532

552

558

26.5

28

20

12

86

500

715

650

609

532

552

558

31.5

34

20

12

91

600

780

725

682

635

655

663

30

31

20

12

96

600

840

770

720

635

655

663

36

37

20

12

100

700

895

840

794

738

760

768

32.5

31

24

12

98

700

910

840

794

738

760

768

39.5

37

24

12

105

800

1015

950

901

842

866

876

35

34

24

12

100

800

1025

950

901

842

866

876

43

40

24

12

108

900

1115

1050

1001

945

971

981

37.5

34

28

12

103

900

1125

1050

1001

945

971

981

46.5

40

28

12

112

1000

1230

1160

1112

1048

1076

1086

40

37

28

12

120

1000

1255

1170

1112

1048

1076

1086

50

43

28

12

130

1100

1340

1270

1218

1152

1180

1190

42.5

37

32

12

123

1100

1355

1270

1218

1152

1180

1190

53.5

43

32

12

134

1200

1455

1380

1328

1255

1285

1295

45

40

32

15

128

1200

1485

1390

1328

1255

1285

1295

57

49

32

15

138

1400

1675

1590

1530

1462

1496

1512

46

43

36

15

138

1400

1685

1590

1530

1462

1496

1512

60

49

36

15

152

1500

1785

1700

1640

1565

1601

1617

47.5

43

36

15

140

1500

1820

1710

1640

1565

1601

1617

62.5

56

36

15

155

1600

1915

1820

1750

1668

1706

1722

49

49

40

15

142

1600

1930

1820

1750

1668

1706

1722

65

56

40

15

158

1800

2115

2020

1950

1875

1917

1933

52

49

44

15

145

1800

2130

2020

1950

1875

1917

1933

70

56

44

15

163

2000

2325

2230

2150

2082

2126

2136

55

49

48

15

148

2000

2345

2230

2150

2082

2126

2136

75

62

48

15

168

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

233

(44)Welded Puddle Flanges (Refer to Figure 44 and Table 49)

PN25 (Refer to Figure 43 and Table 48)


Table 48 Technical Parameters for Welded-on Flange PN25

234

Unit:mm

DN

D1

D2

D3

D4

D5

D6

80

220

160

132

98

112

118

19

19

50

100

235

190

156

118

133

139

19

23

60

125

270

220

184

144

158

164

19

28

60

150

300

250

211

170

186

192

20

28

60

200

360

310

274

222

239

245

22

28

12

62

250

425

370

330

274

294

300

24.5

31

12

10

63.5

300

485

430

389

326

346

352

27.5

31

16

10

73

350

555

490

448

378

398

408

30

34

16

10

76

400

620

550

503

429

449

459

32

37

16

10

78

450

670

600

548

480

500

510

34.5

37

20

12

81

500

730

660

609

532

552

562

36.5

37

20

12

83

600

845

770

720

635

655

665

42

40

20

12

90

700

960

875

820

738

760

776

46.5

43

24

12

95

800

1085

990

928

842

866

886

51

49

24

15

100

900

1185

1090

1028

945

971

991

55.5

49

28

15

105

1000

1320

1210

1140

1048

1076

1096

60

56

28

15

110

1100

1420

1310

1240

1152

1180

1200

64.5

56

32

15

115

1200

1530

1420

1350

1255

1285

1305

69

56

32

15

120

1400

1755

1640

1560

1462

1496

1516

74

62

36

15

125

1500

1865

1750

1678

1565

1601

1625

77.5

62

36

15

130

1600

1975

1860

1780

1668

1706

1726

81

62

40

15

132

1800

2195

2070

1985

1875

1917

1937

88

70

44

15

139

2000

2425

2300

2210

2082

2126

2150

95

70

48

15

188

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Figure 44 Welded Puddle Flanges

Table 49 Technical Parameters for Welded Puddle Flanges


Specification

PN10

Unit:mm

PN16

PN25

DN

D1

D2

D1

D2

D1

D2

80

220

98

16

220

98

16

220

98

16

100

220

118

16

220

118

16

235

118

16

125

250

144

16

250

144

16

270

144

16

150

285

170

16

285

170

16

300

170

17

200

340

222

17

340

222

17

360

222

19

250

400

274

19

400

274

19

425

274

21.5

300

455

326

20.5

455

326

20.5

485

326

23.5

350

505

378

20.5

520

378

22.5

555

378

26

400

565

429

20.5

580

429

24

620

429

28

450

615

480

20.5

640

480

26

670

480

30.5

500

670

532

22.5

715

532

27.5

730

532

32.5

600

780

635

25

840

635

31

845

635

37

700

895

738

27.5

910

738

34.5

960

738

41.5

800

1015

842

30

1025

842

38

1085

842

46

Xinxing Ductile Iron Pipes Technical Manual

235

900

1115

945

32.5

1125

945

41.5

1185

945

50.5

1000

1230

1048

35

1255

1048

45

1320

1048

55

1100

1340

1152

37.5

1355

1152

48.5

1420

1152

59.5

1200

1455

1255

40

1485

1255

52

1530

1255

64

1400

1675

1462

41

1685

1462

55

1755

1462

69

1500

1785

1565

42.5

1820

1565

57.5

1865

1565

72.5

1600

1915

1668

44

1930

1668

60

1975

1668

76

1800

2115

1875

47

2130

1875

65

2195

1875

83

2000

2325

2082

50

2345

2082

70

2425

2082

90

(45)Blank Flanges

Table 50 Technical Parameters for Blank Flange (PN10)

Unit:mm

DN

80

200

19

16

100

220

19

16

125

250

19

16

150

285

19

16

200

340

20

17

250

400

22

19

300

455

24.5

20.5

350

505

24.5

20.5

325

400

565

24.5

20.5

375

450

615

25.5

21.5

425

500

670

26.5

22.5

475

600

780

30

25

575

700

895

32.5

27.5

675

800

1015

35

30

775

900

1115

37.5

32.5

875

1000

1230

40

35

975

1100

1340

42.5

37.5

1075

1200

1455

45

40

1175

1400

1675

46

41

1375

1500

1786

47.5

42.5

1475

1600

1915

49

44

1575

1800

2115

52

47

1775

2000

2325

55

50

1975

PN16 (Refer to Figure 45 and Table 51)


Table 51 Technical Parameters for Blank Flange (PN16)

(a) DN300

(b) DN>300

Figure 45 Blank Flanges PN10

PN10 (Refer to Figure 45 and Table 50)

236

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Unit:mm

DN

80

200

19

16

100

220

19

16

125

250

19

16

150

285

19

16

200

340

20

17

250

400

22

19

300

455

24.5

20.5

350

520

26.5

22.5

325

Xinxing Ductile Iron Pipes Technical Manual

237

400

580

28

24

375

450

640

30

26

425

500

715

31.5

27.5

475

600

840

36

31

575

700

910

39.5

34.5

675

800

1025

43

38

775

900

1125

46.5

41.5

875

1000

1255

50

45

975

1100

1355

53.5

48.5

1075

1200

1485

57

52

1175

1400

1685

60

55

1375

1500

1820

62.5

57.5

1475

1600

1930

65

60

1575

1800

2130

70

65

1775

2000

2345

75

70

1975

(46)Reducing Flanges

Figure 46 Blank PN10

PN25 (Refer to Figure 45 and Table 52)


PN10 (Refer to Figure 46 and Table 53)
Table 52 Technical Parameters for Blank Flange(PN25)

Unit:mm
Table 53 Technical Parameters for Reducing Flanges (PN10)

238

Unit:mm

DN

80

200

19

16

DNdn

D1

D2

D3

D4

D5

D6

n1

n2

100

235

19

16

20080

340

295

118

84

160

200

23

16

39

125

270

19

16

200100

340

295

144

104

180

220

23

16

39

150

300

20

17

25080

400

350

118

84

160

200

12

23

16

41

200

360

22

19

250100

400

350

148

104

180

220

12

23

16

41

250

425

24.5

21.5

250150

400

350

200

154

240

285

12

23

20

43

300

485

27.5

23.5

350

555

30

26

325

30080

455

400

118

84

160

200

12

23

16

44

400

620

32

28

375

300100

455

400

148

104

180

220

12

23

16

44

450

670

34.5

30.5

425

300150

455

400

200

154

240

285

12

23

20

44

500

730

36.5

32.5

475

300200

455

400

250

205

295

340

12

23

20

45

600

845

42

37

575

35080

505

460

118

84

160

200

16

23

16

44

700

960

46.5

41.5

675

350100

505

460

148

104

180

220

16

23

16

44

800

1085

51

46

775

350150

505

460

203

155

240

285

16

23

20

44

900

1185

55.5

50.5

875

350200

505

460

250

205

295

340

16

23

20

44

1000

1320

60

55

975

350250

505

460

303

254

350

400

16

12

23

20

47

1200

1530

69

64

1075

40080

565

515

118

84

160

200

16

28

16

44

1400

1755

74

69

1175

400100

565

515

148

104

180

220

16

28

16

44

1600

1975

81

76

1375

1800

2195

88

83

1475

400150

565

515

205

155

240

285

16

28

20

44

2000

2425

95

90

1575

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

239

240

400200

565

515

270

205

295

340

16

28

20

45

400250

565

515

303

254

350

400

16

12

28

20

47

400300

565

515

354

309

400

455

16

12

28

20

49

50080

670

620

118

84

160

200

20

28

16

46

500100

670

620

148

104

180

220

20

28

16

46

500150

670

620

203

155

240

285

20

28

20

46

500200

670

620

250

205

295

340

20

28

20

47

500250

670

620

303

254

350

400

20

12

28

20

49

500300

670

620

354

309

400

455

20

12

28

20

51

500350

670

620

409

354

460

505

20

16

28

20

51

500400

670

620

464

409

515

565

20

16

28

24

51

60080

780

725

118

84

160

200

20

31

16

49

600100

780

725

148

104

180

220

20

31

16

49

600150

780

725

205

155

240

285

20

31

20

49

600200

780

725

250

205

295

340

20

31

20

50

600250

780

725

303

254

350

400

20

12

31

20

52

600300

780

725

354

309

400

455

20

12

31

20

55

600350

780

725

409

354

460

505

20

16

31

20

55

600400

780

725

464

409

515

565

20

16

31

24

55

600450

780

725

515

455

565

615

20

20

31

24

55

80080

1015

950

118

84

160

200

24

34

16

54

800100

1015

950

148

104

180

220

24

34

16

54

800150

1015

950

205

155

240

295

24

34

20

54

800200

1015

950

250

205

295

340

24

34

20

55

800250

1015

950

303

254

350

400

24

12

34

20

57

800300

1015

950

354

309

400

455

24

12

34

20

60

800350

1015

950

409

354

460

505

24

16

34

20

60

800400

1015

950

464

409

515

565

24

16

34

24

60

800450

1015

950

515

455

565

615

24

20

34

24

60

800500

1015

950

566

508

620

670

24

20

34

24

62

800600

1015

950

670

608

725

780

24

20

34

27

65

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

PN16 (Refer to Figure 46 and Table 54)

Table 54 Technical Parameters for Reducing Flanges (PN16)

Unit:mm

DNdn

D1

D2

D3

D4

D5

D6

n1

n2

20080

340

295

118

84

160

200

12

23

16

39

200100

340

295

144

104

180

220

12

23

16

39

25080

400

355

118

84

160

200

12

28

16

41

250100

400

355

148

104

180

220

12

28

16

41

250150

400

355

200

154

240

285

12

28

20

43

30080

455

410

118

84

160

200

12

28

16

44

300100

455

410

148

104

180

220

12

28

16

44

300150

455

410

200

154

240

285

12

28

20

44

300200

455

410

250

205

295

340

12

12

28

20

45

35080

520

470

118

84

160

200

16

28

16

45

350100

520

470

148

104

180

220

16

28

16

45

350150

520

470

203

155

240

285

16

28

20

45

350200

520

470

250

205

295

340

16

12

28

20

46

350250

520

470

303

254

355

400

16

12

28

24

48

40080

580

525

118

84

160

200

16

31

16

47

400100

580

525

148

104

180

220

16

31

16

47

400150

580

525

205

155

240

285

16

31

20

47

400200

580

525

270

205

295

340

16

12

31

20

48

400250

580

525

303

254

355

400

16

12

31

24

50

400300

580

525

354

309

410

455

16

12

31

24

52

50080

715

650

118

84

160

200

20

34

16

50

500100

715

650

148

104

180

220

20

34

16

50

500150

715

650

203

155

240

285

20

34

20

50

500200

715

650

250

205

295

340

20

12

34

20

50

500250

715

650

303

254

350

400

20

12

34

24

52

500300

715

650

354

309

400

455

20

12

34

24

56

500350

715

650

409

354

470

520

20

16

34

24

58

500400

715

650

464

409

525

580

20

16

34

27

60

60080

840

770

118

84

160

200

20

37

16

55

600100

840

770

148

104

180

220

20

37

16

55

600150

840

770

205

155

240

285

20

37

20

55

600200

840

770

250

205

295

340

20

12

37

20

56

Xinxing Ductile Iron Pipes Technical Manual

241

600250

840

770

303

254

355

400

20

12

37

24

58

400100

620

550

148

104

190

235

16

37

20

51

600300

840

770

354

309

410

455

20

12

37

24

60

400150

620

550

205

155

250

300

16

37

24

52

600350

840

770

409

354

470

520

20

16

37

24

62

400200

620

550

270

205

310

360

16

12

37

24

54

600400

840

770

464

409

525

580

20

16

37

27

64

400250

620

550

303

254

370

425

16

12

37

27

56

600450

840

770

515

455

585

640

20

20

37

27

66

400300

620

550

354

309

430

485

16

16

37

27

60

80080

1025

950

118

84

160

200

24

40

16

62

50080

730

660

118

84

160

200

20

37

16

55

800100

1025

950

148

104

180

220

24

40

16

62

500100

730

660

148

104

190

235

20

37

20

55

800150

1025

950

205

155

240

295

24

40

20

62

500150

730

660

203

155

250

300

20

37

24

56

800200

1025

950

250

205

295

340

24

12

40

20

63

500200

730

660

250

205

310

360

20

12

37

24

58

800250

1025

950

303

254

355

400

24

12

40

24

65

500250

730

660

303

254

370

425

20

12

37

27

61

800300

1025

950

354

309

410

455

24

12

40

24

67

500300

730

660

354

309

430

485

20

16

37

27

64

800350

1025

950

409

354

470

520

24

16

40

24

68

500350

730

660

409

354

490

555

20

16

37

30

66

800400

1025

950

464

409

525

580

24

16

40

27

70

500400

730

660

464

409

550

620

20

16

37

33

68

800450

1025

950

515

455

585

640

24

20

40

27

73

60080

845

770

118

84

160

200

20

40

16

61

800500

1025

950

566

508

650

715

24

20

40

30

74

600100

845

770

148

104

190

235

20

40

20

61

800600

1025

950

670

608

770

840

24

20

40

33

79

600150

845

770

205

155

250

300

20

40

24

62

600200

845

770

250

205

310

360

20

12

40

24

64

600250

845

770

303

254

370

425

20

12

40

27

66

600300

845

770

354

309

430

485

20

16

40

27

70

600350

845

770

409

354

490

555

20

16

40

30

72

600400

845

770

464

409

550

620

20

16

40

33

74

600450

845

770

515

455

600

670

20

20

40

33

76

80080

1085

990

118

84

160

200

24

49

16

70

800100

1085

990

148

104

190

235

24

49

20

70

800150

1085

990

205

155

250

300

24

49

24

71

800200

1085

990

250

205

310

360

24

12

49

24

73

800250

1085

990

303

254

370

425

24

12

49

27

75

800300

1085

990

354

309

430

485

24

12

49

27

78

800350

1085

990

409

354

490

555

24

16

49

30

81

800400

1085

990

464

409

550

620

24

16

49

33

83

800450

1085

990

515

455

600

670

24

20

49

33

85

800500

1085

990

566

508

660

730

24

20

49

33

87

800600

1085

990

670

608

770

845

24

20

49

36

93

PN25 (Refer to Figure 46 and Table 55)


Table 55 Technical Parameters for Reducing Flanges (PN25)

242

Unit:mm

DNdn

D1

D2

D3

D4

D5

D6

n1

n2

20080

360

310

118

84

160

200

12

28

16

41

200100

360

310

144

104

190

235

12

28

20

41

25080

425

370

118

84

160

200

12

31

16

43

250100

425

370

148

104

190

235

12

31

20

43

250150

425

370

200

154

250

300

12

31

24

44

30080

485

430

118

84

160

200

16

31

16

46

300100

485

430

148

104

190

235

16

31

20

46

300150

485

430

200

154

250

300

16

31

24

47

300200

485

430

250

205

310

360

16

12

31

24

50

35080

555

490

118

84

160

200

16

34

16

49

350100

555

490

148

104

190

235

16

34

20

49

350150

555

490

203

155

250

300

16

34

24

50

350200

555

490

250

205

310

360

16

12

34

24

52

350250

555

490

303

254

370

425

16

12

34

27

54

40080

620

550

118

84

160

200

16

37

16

51

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

243

(48)Bolts for Flange Connection (Refer to Figure 48 and Table 57)

(47)Flexible Puddle Flanges (Refer to Figure 47 and Table 56)

L
Figure 48 Bolts for Flange Connection

Table 57 Technical Parameters for Bolts for Flange Connection


Figure 47 Flexible Puddle Flanges
DN
Table 56 Technical Parameters for Flexible Puddle Flanges

244

Unit:mm

PN10

PN16

Unit:mm

PN25

PN40

Quantity

ML

Quanti

ML

Quanti

ML

Quanti

ML

80

M1665

M1665

M1665

M1665

1OO

M1665

M1665

M2070

M2070

125

M1665

M1665

M2480

M2480

150

M2070

M2070

M2480

M2490

200

M2070

12

M2070

12

M2480

12

M27100

250

12

M2080

l2

M2490

12

M2790

12

M30110

300

12

M2080

12

M2490

16

M2790

16

M3O120

DN

MK

80

110

260

100

M16

80

100

110

306

120

M16

80

150

130

390

172

M20

90

200

130

430

224

M20

90

250

130

490

276

M20

90

350

16

M2080

l6

M2490

16

M30110

16

M33130

300

130

555

329

M20

100

400

l6

M2490

16

M27100

16

M33120

16

M36140

350

130

610

381

M20

100

450

20

M2490

20

M27100

20

M33120

20

M36150

400

150

660

432

M24

110

500

20

M2490

20

M30110

20

M33120

20

M39150

450

150

725

483

M24

110

600

20

M27l00

20

M33120

20

M36140

20

M45170

500

160

790

535

M24

110

700

24

M27100

24

M33120

24

M39l40

600

165

900

10

638

M27

120

800

24

M30110

24

M36140

24

M45160

700

182

970

10

742

M27

120

900

28

M30120

28

M36140

28

M45170

800

194

1086

10

742

M30

120

1000

28

M33130

28

M39150

28

M52180

900

194

1188

10

949

M30

120

1100

32

M33130

32

M39160

32

M52180

1000

208

1310

10

1053

M33

130

1200

32

M36140

32

M45170

32

M52200

1200

220

1536

10

1260

M36

130

l400

36

M39150

36

M45180

36

M56220

1500

36

M39150

36

M52190

36

M56230

1400

240

1752

10

1468

M39

130

1600

40

M45160

40

M52190

40

M56230

1800

44

M45160

44

M52200

44

M64260

2000

48

M45l70

48

M56220

48

M64270

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

245

(49)Bolts for K-Joint Connection (Refer to Figure 49 and Table 58)

Figure 49 Bolts for K-Joint Connection

Table 58 Technical Parameters for Bolts for K-Joint Connection


DN

Diameter of
Thread

Unit:mm

65

40

30

16

75

55

36

21.5

75

46

25.6

95
100~600

M20

100
110

700~800

M24

900

120
130

1000
1100

140

1200

85

1400
1500
1600
1800
2000
2200
2400
2600

246

XINXING PIPES

M30

150

160

170
180

90

100

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

247

Chapter VII
Valves for
Water Supply
and Drainage
Pipeline

248

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

249

Chapter VII
Valves for
Water Supply
and Drainage
Pipeline

250

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

7.1 Brief Introduction to Valves 252


7.1.1 Rubber Sealed Gate Valve
7.1.2 butterfly valve (Long body)
7.1.3 butterfly valve (Short body
7.1.4 butterfly valve internally sealed with rubber
7.1.5 eccentric ball valve
7.1.6 Rubber Flap Check Valve
7.2 Before Purchasing 272

Xinxing Ductile Iron Pipes Technical Manual

251

In the water supply and drainage piping system, the valve is control element, its main function is to isolate

Executive Standard.

the equipment from the piping system, regulate the flow, prevent the backflow, adjust the pressure, etc.

To BS5150/BS5163 btype A

Therefore, whether these functions of valves can be normally realized will influence the normal and safe

Face to face dimension to BS 5163

water supply of pipeline. When the pipeline is in normal state of water supply, the valve shall be open, so as

Flanges and drilling to ISO7005-2(EN1093-2),DIN 2501

to reduce the water head loss; Once the pipeline need to cut off the water flow, the valve should be turned

Structure and Technical Parameter

off rapidly, to realize sound flow-cut. Therefore, valve quality will play a key role in normal operation of
pipeline.
Besides ductile cast iron pipes, fittings and relevant technical services, Xinxing would also provides the
customers with the products required for water supply and drainage piping engineering, such as valves.
Should there be any requirements, please contact with our sales staff.

7.1 Brief Introduction to Valves


The valves most commonly-used include gate valve, butterfly valve, ball valve, check valve etc. With the
ongoing research and development, product materials and specifications are always under change, which
might not be companied with further notice. The following dimensions and technical parameters of valves
are for reference only; specific parameters are subject to the actual contract.

7.1.1 Rubber Sealed Gate Valve

Component List
Sr-no.

Part name

Material

Body

Ductile iron

Wedge

Ductile iron+EPDM or NBR

Stem

Stainless steel +Al-Bronze

Bonnet

Ductile iron

Bearing

Environmenral protection steel base

Gland

Ductile oiron

Product technical parameters


PN

0.6

1.0

1.6

2.0

2.5

4.0

DN

50-500

50-500

50-500

50-350

50-300

50-300

Seal test

0.66

1.10

1.76

2.20

2.75

4.40

Seal test

0.90

1.50

2.40

3.00

3.75

6.00

Suotable temperature:-10~80oC
Suotable medium:water, oil, air and weak corrosive fluid etc.
Operation type:Square head or handwreel,wormgear,pneumatic,electric

252

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

253

Form and Dimensions

DN

PN

D1

D2

D3

0.6

320

280

n-d

254

22

8-19

340

295

266

20

345

298.5

270

28.5

8-22

2.5

360

310

274

22

12-28

375

320

284

30

12-31

0.6

375

335

309

24

12-19

395

350

319

22

12-23

355

319

22

12-28

362

324

30

12-26

24.5

12-31

34.5

12-34

1
200

250

DN

PN

D1

D2

D3

0.6

140

110

88

165

125

99

1
50

1.6
2
2.5
4
0.6
1

80

1.6
2
2.5
4
0.6
1

100

1.6
2
2.5
4
0.6
1

150

1.6
2
2.5
4

254

XINXING PIPES

178

n-d

16

4-14

19

4-19

155

12.5

92

16

4-18

165

125

99

19

4-19

190

150

124

18

4-19

200

160

132

190

152.5

127

200

160

132

210

170

144

220

180

156

4230

190.5

235

216

19

8-19

19

4-19

19

8-19

18

4-19

19

8-19

157

24

8-18

190

156

19

8-23

265

225

199

20

8-19

285

240

211

19

8-23

280
300

241.5
250

216
211

203

283

229

305
267

267

25.5
20

403

26

8-22

H1

82

H2

210

300

1.6

1.6
2

105

260

400

450
115

305

500

292

419

330

12-23

425

370

330

450

385

345

0.6

440

395

363

24

12-23

445

400

370

24.5

12-23

1.6

460

410

370

24.5

12-28

432

381

32

12-26

430

389

27.5

18-01

39.5

16-34

26

12-23

24.5

16-23

26.5

16-28

485

457

356

502

515

450

409

0.6

490

445

413

505

460

429

1.6

520

470

429

535

476

413

35

12-29.5

0.0

540

495

403

26

16-23

565

515

480

24.5

16-28

1.6

580

525

480

28

16-31

0.0

595

550

518

26

16-23

615

565

530

25.5

20-28

1.6

640

585

548

30

20-31

0.6

645

600

568

30

20-23

670

620

582

26.5

20-28

1.6

715

650

609

31.5

20-34

381

406

432

457

H1

H2

175

485

200

575

230

650

260

750

290

845

315

930

345

100

8-23

2.5

2.5

350

405

Remarks:The dimension with in the form is only for your reference.


148

390

The detailed dimen sion will be based on the actual Product.


If there is any request for larger sizes,please contact us indetail.

8-28

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

255

7.1.2 butterfly valve (Long body)

Component list
Sr.no

Parts name

Material

Upper shaft

SS420

Shaft bearing

Al-bronze

Body

Ductile iron

Seat ring

EPDM/NBR/VITON

Disc

Ductile iron

Retainer ring

SS304

Body seal ring

SS304

Lower shaft

SS420

(Cther materials are available on request)


Size:DN100-DN4000

Executive Standard.

Pressure:PN6-PN40

Double flanged type

Coating:fusion bonded epoxy coating min.thickness250micron


Suitable medium:water and low-corrosive liquid etc.

Face to face length acc.to ISO 5752 series 14(DIN3202 F4)

Suitable temperature:-10-120

Flange dimensions and drilling acc. to ISO7005-2(EN 1092-2,DIM2501)


Structure and Technical Parameter

Form and Dimensions


Dimensions/PN10

256

DN

150

210

170

200

40

22

70

200

230

197

233

45

30

250

250

223

261

60

30

300

270

251

295

70

350

290

294

330

400

310

329

450

330

500

unit:mm
top works
bot hole dia

holes nes

ISO5211

90

F07

102

125

12

F10

102

125

12

F10

40

12

125

150

14

F12

80

40

12

125

150

14

F12

386

90

50

14

140

175

18

F14

365

411

100

50

14

140

175

18

F14

350

394

445

90

65

18

165

210

22

F16

Sr.no

Component

Sr.no

Component

600

390

454

519

120

65

18

165

210

22

F16

Top flange

Retainer ring

700

430

537

585

100

85

22

254

300

18

F25

Upper shaft

Disc

800

470

593

641

120

85

22

254

300

18

F25

O ring

10

Shaft bearing

900

510

657

706

125

90

25

254

300

18

F25

Shaft bearing

11

O ring

1000

550

722

771

125

100

28

254

300

18

F25

O ring

12

Shaft cover

120

630

845

893

155

120

32

298

350

22

F30

Body

13

Body seal ring

1400

710

967

1019

155

120

32

356

415

33

F35

Seat

14

Key

1600

790

1113

1111

198

150

36

406

475

39

F40

1800

870

1251

1244

333

128

32

406

475

39

12

F48

2000

950

1340

1330

400

170

40

483

560

39

12

F48

2200

1000

1420

1450

400

200

45

483

560

39

12

F48

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

257

Dimensions/PN16
DN

150

210

167

200

40

22

70

200

230

197

233

55

30

250

250

224

282

60

40

300

270

267

313

80

350

290

303

357

400

310

339

450

330

500

unit:mm
top works

DN

bot hole dia

holes nes

ISO5211

90

F07

150

210

186

225

60

40

12

136

102

125

12

F10

200

230

235

260

55

40

12

12

125

150

14

F12

250

250

260

307

70

50

40

12

125

150

14

F12

300

270

285

340

95

90

50

14

140

175

18

F14

350

290

320

382

396

110

50

14

140

175

18

F14

400

310

402

379

443

100

65

18

165

210

22

F16

450

330

350

404

469

120

65

18

165

210

22

F16

500

600

390

486

545

120

85

22

254

300

18

F25

700

430

537

590

120

85

22

254

300

18

F25

800

470

606

655

140

90

25

254

300

18

F25

900

510

699

711

150

100

28

298

350

22

F30

1000

550

776

791

170

110

28

298

350

22

1200

630

874

921

240

128

32

356

415

33

1400

710

1034

1038

290

170

40

406

475

1600

790

1175

1118

400

170

40

483

1800

820

1320

1335

400

170

40

2000

950

1460

1475

400

200

2200

1000

1650

1665

400

200

ISO5211

160

14

F10

125

150

14

F12

14

140

175

18

F14

50

14

140

175

18

F14

90

65

18

165

210

22

F16

435

140

65

18

210

260

22

F25

390

470

105

85

22

254

300

18

F25

350

476

496

170

95

25

298

350

22

F30

600

390

517

599

155

100

28

298

350

22

F30

700

430

661

615

244

128

32

406

475

39

F40

800

470

710

780

250

128

32

406

475

39

F40

900

510

760

880

280

128

32

406

475

39

F40

F30

1000

550

820

920

280

185

45

483

560

39

12

F48

F35

1200

630

1077

1174

303

185

45

483

560

39

12

F48

39

F40

1400

710

1100

1220

480

200

45

603

686

39

20

F60

560

39

12

F48

483

560

39

12

F48

45

483

560

39

12

F48

45

483

560

39

12

F48

150

210

188

219

50

30

102

200

230

221

245

80

40

12

250

250

265

280

80

40

300

270

298

312

110

350

290

318

365

400

310

369

450

330

500

7.1.3 butterfly valve (Short body)

unit:mm
top works
bot hole dia

holes nes

ISO5211

125

12

F10

140

175

18

F14

12

140

175

18

F14

50

14

165

210

18

F16

120

55

16

165

210

18

F16

416

120

65

18

165

210

88

F16

375

458

120

65

18

165

210

22

F16

350

420

484

150

85

22

254

300

18

F25

600

390

499

555

170

85

22

254

300

18

F25

Executive Standard.

700

430

601

615

230

100

28

298

350

18

F30

800

470

668

697

230

100

28

356

415

33

F35

Double flanged type

900

510

730

750

200

125

32

356

415

33

F35

1000

550

819

828

321

140

36

406

475

39

F40

1200

630

995

1004

260

170

40

483

560

39

12

F48

1400

710

1150

1124

279

170

40

483

560

39

12

F4

XINXING PIPES

top works
holes nes

DN

unit:mm

bot hole dia

Dimensions/PN25

258

Dimensions/PN40

Xinxing Ductile Iron Pipes Technical Manual

Face to face length acc.to ISO 5752 series 13(EN558-1 series 13)
Flange dimensions and drilling acc. to ISO7005-2(EN 1092-2,DIM2501)

Xinxing Ductile Iron Pipes Technical Manual

259

Form and Dimensions

Structure and Technical Parameter

Dimensions/PN10

Component List
Sr.no

Parts name

Material

Upper shaft

SS420

Shaft bearing

Al-bronze

Body

Ductile iron

Seat ring

EPDM/NBR/VITON

Disc

Ductile iron

Retainer ring

SS304

Lower Shaft

SS420

DN

150

140

156

232

40

22

70

200

152

190

280

45

30

250

165

210

308

60

30

300

178

240

355

70

350

190

274

390

400

216

308

450

222

500

unit:mm
top works
bolt hole dia.

holes nos

ISO5211

100

F07

102

125

12

F10

102

125

12

F10

40

12

125

150

14

F12

80

40

12

125

150

14

F12

446

90

50

14

140

175

18

F14

333

476

100

50

14

140

175

18

F14

229

358

506

90

65

18

165

210

22

F16

600

267

424

586

120

65

18

170

210

22

F16

700

292

480

646

100

85

22

254

300

18

F25

800

318

544

730

12

85

22

254

300

18

F25

900

330

594

790

125

90

25

254

300

18

F25

1000

410

654

880

125

100

28

254

300

18

F25

1200

470

786

1000

155

120

32

298

350

22

F30

1400

530

916

1160

155

128

32

356

415

33

F35

1600

600

1040

1291

198

150

36

406

475

39

F40

1800

670

1160

1450

333

128

32

483

560

39

12

F48

2000

760

1312

1604

400

170

40

483

560

39

12

F48

2200

800

1388

1730

400

200

45

483

560

39

12

F48

2400

900

1620

1924

480

200

45

603

686

39

200

F60

If there is any request for larger sizes,please contact us in detail.

(Other materials are available on request)


Size:DN100-DN400
Pressure:PN6-PN40
Coating:fusion bonded epoxy coating min.thickness250micron
Suitable medium:water and low-corrosive liquid etc.
Suitable temperature:-10-120

260

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

261

Dimensions/PN16
DN

150

140

156

232

40

22

70

200

152

190

280

55

30

250

165

220

330

60

40

300

178

248

360

80

350

190

280

420

400

216

312

450

222

500

unit:mm

7.1.4 butterfly valve internally sealed with rubber

top works
bolt hole dia.

holes nos

ISO5211

100

F07

102

125

12

F10

12

125

150

14

F12

40

12

125

150

14

F12

90

50

14

140

175

18

F14

454

110

50

14

140

175

18

F14

345

510

100

65

18

165

210

22

F16

229

384

550

120

65

18

165

210

22

F16

600

267

450

620

120

85

22

254

300

18

F25

700

292

494

685

130

85

22

254

300

18

F25

800

318

564

750

140

90

25

254

300

18

F25

900

330

617

846

165

100

28

298

350

22

F30

1000

410

715

915

165

125

32

356

415

33

F35

1200

470

841

1086

240

125

32

356

415

33

F35

1400

530

973

1240

235

160

40

406

475

39

F40

1600

600

1170

1404

400

170

40

483

560

39

12

F48

1800

670

1320

1590

400

170

40

483

560

39

12

F48

2000

760

1460

1730

400

200

45

483

560

39

12

F48

Executive Standard.
Double flanged type
Face to face length acc.to ISO 5752 series 13(EN558-1 series 13)
Flange dimensions and drilling acc. to ISO7005-2(EN 1092-2,DIM2501)
Structure and Technical Parameter

If there is any request for larger sizes,please contact us in detail.

262

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Sr.no

Component

Sr.no

Component

Upper shaft

Disc

Top flange

Body

Packing gland

10

Shaft bearing

Shaft bearing

11

O ring

O ring

12

Lower shaft

Seat

13

Key

Retainer ring

Xinxing Ductile Iron Pipes Technical Manual

263

Component List

Dimensions/PN16

Sr.no

Parts name

Material

Upper shaft

SS420

Shaft bearing

DN

Al-bronze

150

210

167

200

40

22

70

Body

Dl+rubber

200

230

197

233

55

30

Seat ring

EPDM/NBR/VITON

250

250

224

282

60

40

Disc

Dl+rubber

300

270

267

313

80

Retainer ring

SS 316/duplex st.st.

350

290

303

357

Lower Shaft

SS420

400

310

339

450

330

Size:DN100-DN400

500

Pressure:PN6-PN40
Coating:epoxy painting min.thickness200micron

(Other materials are available on request)

Suitable medium:water and low-corrosive liquid etc.


Suitable temperature:-10-120

Form and Dimensions


Dimensions/PN10
DN

150

210

170

200

40

22

70

200

230

197

233

45

30

250

250

223

261

60

30

300

270

251

295

70

350

290

294

330

400

310

329

450

330

500

unit:mm
top works
bolt hole dia.

holes nos

ISO5211

90

F07

102

125

12

F10

102

125

12

F10

40

12

125

150

14

F12

80

40

12

125

150

14

F12

386

90

50

14

140

175

18

F14

365

411

100

50

14

140

175

18

F14

350

394

445

90

65

18

165

210

22

F16

600

390

454

519

120

65

18

165

210

22

F16

700

430

537

585

100

85

22

254

300

18

F25

800

470

593

641

120

85

22

254

300

18

F25

900

510

657

706

125

90

25

254

300

18

F25

1000

550

722

771

125

100

28

254

300

18

F25

1200

630

845

893

155

120

32

298

350

22

F30

1400

710

967

1019

155

120

32

356

415

33

F35

1600

790

1113

1111

198

150

36

406

475

39

F40

1800

870

1251

1244

333

128

32

406

475

39

12

F48

2000

950

1340

1330

400

170

40

483

560

39

12

F48

2200

1000

1420

1450

400

200

45

483

560

39

12

F48

unit:mm
top works
bolt hole dia.

holes nos

ISO5211

90

F07

102

125

12

F10

12

125

150

14

F12

40

12

125

150

14

F12

90

50

14

140

175

18

F14

396

110

50

14

140

175

18

F14

379

443

100

65

18

165

210

22

F16

350

404

469

120

65

18

165

210

22

F16

600

390

486

545

120

85

22

254

300

18

F25

700

430

537

590

120

85

22

254

300

18

F25

800

470

606

655

140

90

25

254

300

18

F25

900

510

699

711

150

100

28

298

350

22

F30

1000

550

776

791

170

110

28

298

350

22

F30

1200

630

874

921

240

128

32

356

415

33

F35

1400

710

1034

1038

290

170

40

406

475

39

F40

1600

790

1175

1188

400

170

40

483

560

39

12

F48

1800

820

1320

1335

400

170

40

483

560

39

12

F48

2000

950

1460

1475

400

200

45

483

560

39

12

F48

2200

1000

1650

1665

400

200

45

483

560

39

12

F48

7.1.5 eccentric ball valve

If there is any request for larger sizes,please contact us in detail.

264

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

265

Executive Standard.

Component List

Double flanged type


Face to face length acc.to ISO 5752/EN558-1 series 3( DN300,enterprise standard)

Sr.no

Parts name

Material

Upper shaft

SS420

Packing

Flexible graphite/O ring

Shaft bearing

Al-bronze

Body

Ductile iron or WCB

Seat

Hard alloy

Disc

WCB

Lower Shaft

SS420

Flange dimensions and drilling acc. to ISO7005-2/EN 1092-2/ DIn 2501)


Structure and Technical Parameter

Other materials are available on request)


Coating:epoxy painting min.thickness200micron
Suitable medium:water,waste water,oil,grained slurry,and weak-corrosive liquid
etc.
Suitable temperature:-29-425

Form and Dimensions


Dimensions/PN10

Sr.no

Component

Sr.no

Component

Key

Disc

Upper shaft

Body

Top flange

10

Retainer ring

Packing gland

11

Seat

Packing

12

Shaft bearing

Gasket

13

LOWER SHAFT

Shaft bearing

14

Shaft cover

DN

100

229

130

225

70

30

102

125

254

148

245

75

30

150

267

173

276

95

40

200

292

195

320

98.5

250

330

225

362

300

356

260

350

440

400

unit:mm
top works
bolt hole dia.

holes nos

ISO5211

125

11

F10

102

125

11

F10

12

125

150

14

F12

40

12

125

150

14

F12

121

50

14

140

175

18

F14

400

123

50

14

140

175

18

F14

300

455

130

65

18

165

210

23

F16

500

332

490

130

65

18

165

210

23

F16

450

560

360

540

130

65

18

165

210

23

F16

500

620

400

610

180

80

22

254

300

18

F25

600

800

519

582

178

80

22

254

300

18

F25

700

850

579

632

180

80

22

298

350

23

F30

800

900

640

675

215

100

28

298

350

23

F30

900

1050

704

770

215

100

28

356

415

33

F35

1000

1200

818

895

310

128

32

356

415

33

F35

1200

1500

978

1055

310

128

32

406

475

39

F40

1400

1650

1147

1200

410

170

40

483

560

39

12

F48

1600

1850

1300

1380

460

210

50

603

686

39

20

F60

If there is any request for larger sizes,please contact us in detail.

266

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

267

Dimensions/PN16
DN

100

229

130

225

70

30

102

125

254

148

245

75

30

150

267

173

276

95

40

200

292

195

320

98.5

250

330

225

362

300

356

260

350

440

400

unit:mm
top works

DN

bolt hole dia.

holes nos

ISO5211

125

11

F10

100

229

130

225

70

30

102

102

125

11

F10

125

254

148

245

75

30

12

125

150

14

F12

150

267

173

276

95

40

40

12

125

150

14

F12

200

292

195

320

98.5

121

50

14

140

175

18

F14

250

330

225

362

400

123

50

14

140

175

18

F14

300

356

260

300

455

130

65

18

165

210

23

F16

350

440

500

332

490

130

65

18

165

210

23

F16

400

450

560

360

540

130

65

18

254

300

18

F25

500

620

400

610

180

80

22

254

300

18

F25

600

800

519

582

214

100

28

298

350

23

F30

700

850

579

786

210

100

28

356

415

33

800

900

790

880

310

128

32

356

415

33

900

1050

805

895

310

128

32

356

415

1000

1200

975

1050

310

128

32

406

1200

1500

1125

1185

410

170

40

1400

1650

1140

1200

410

170

1600

1850

1290

1370

460

210

XINXING PIPES

unit:mm
top works
bolt hole dia.

holes nos

ISO5211

125

11

F10

102

125

11

F10

12

125

150

14

F12

40

12

125

150

14

F12

121

50

14

165

210

23

F16

400

123

50

14

165

210

23

F16

300

455

130

65

18

254

300

18

F25

500

332

490

130

65

18

254

300

18

F25

450

560

365

563

179

80

22

298

350

23

F30

500

620

422

454

175

80

22

298

350

23

F30

600

800

519

582

214

100

28

298

350

23

F30

F35

700

850

579

786

210

100

28

356

415

33

F35

F35

800

900

790

880

310

128

32

356

415

33

F35

33

F35

900

1050

960

1030

310

128

32

406

475

39

F40

475

39

F40

1000

1200

1120

1175

410

170

40

406

475

39

F40

406

475

39

F40

1200

1500

1140

1200

410

170

40

483

560

39

12

F48

40

483

560

39

12

F48

50

603

686

39

20

F60

If there is any request for larger sizes,please contact us in detail.

268

Dimensions/PN25

Xinxing Ductile Iron Pipes Technical Manual

Dimensions/PN40
DN

100

229

130

225

70

30

102

125

254

148

245

75

30

150

267

173

276

95

40

200

292

195

320

98.5

250

330

225

362

300

356

260

350

440

400

unit:mm
top works
bolt hole dia.

holes nos

ISO5211

125

11

F10

102

125

11

F10

12

125

150

14

F12

40

12

125

150

14

F12

121

50

14

165

210

23

F16

400

123

50

14

165

210

23

F16

300

455

130

65

18

254

300

18

F25

500

350

545

180

80

22

298

350

23

F30

450

560

365

563

180

80

22

298

350

23

F30

500

620

460

520

210

100

28

298

350

23

F30

600

800

565

770

210

100

28

356

415

33

F35

700

850

780

865

310

128

32

356

415

33

F35

800

900

945

1015

310

128

32

406

475

39

F40

900

1050

1100

1155

410

170

40

406

475

39

F40

1000

1200

1140

1200

410

170

40

483

560

39

12

F48

1200

1500

1290

1370

460

210

50

603

686

39

20

F60

Xinxing Ductile Iron Pipes Technical Manual

269

7.1.6 Rubber Flap Check Valve


Check valve is mainly used for exit of pipeline pump for water supply and drainage system, petroleum,
chemical industry and other industrial fields, aiming to prevent the backflow of transmitted medium.
Since the product sealing adopts inclined design, closing time is shorter, can reduce the pressure of water
hammer. Valve clack is made through high-temperature pressing of butyronitrile oil resistant rubber and
steel plate; washing-out resistance, good sealing performance, simple product structure; maintenance,
repair and transportation are convenient.

Form and Dimensions

DN
(mm)

D
PN10

D1
PN16

PN10

D2
PN16

PN10

b
PN16

PN10

PN16

Z-d
PN10

PN16

Executive Standard

50

203

190

165

125

99

19

4-19

Design and manufacturing: GB/T 13932

65

216

210

185

145

118

19

4-19

Flange Dimension: BS EN 1092-2

80

241

230

200

160

132

19

8-9

Structural length: BS EN 558-1

100

292

250

220

180

156

19

8-19

Testing and inspection: EN 12226

125

330

280

250

210

184

19

8-19

150

356

315

285

240

211

19

8-23

200

495

370

340

295

266

20

8-23

12-23

250

622

430

395

405

350

355

319

22

12-23

12-28

24.5

12-23

12-28

Product structure and technical parameters

270

size(mm)

Valve Body Valve Cap

Ductile Cast Iron

300

698

475

445

460

400

410

370

Valve Clack

Rubber Assembly

350

787

550

505

520

460

470

429

24.5

26.5

16-23

16-28

400

914

600

565

580

515

525

480

24.5

28

16-28

16-31

450

978

615

640

565

585

530

548

25.5

30

20-28

20-31

500

978

670

715

620

650

582

609

26.5

31.5

20-28

20-34

Nominal Pressure (MPa)

1.0

1.6

600

1295

780

840

725

770

682

720

30

36

20-31

20-37

Shell test Pressure (MPa)

1.5

2.4

800

1956

1015

1025

950

950

901

901

35

43

24-34

24-40

Sealing Test Pressure (MPa)

1.1

1.76

Working Temperature ( )

80

Working Medium

Water, Oil Product, and etc.

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

271

7.2 Before Purchasing


Selected Valve Type: Select the type according to use requirements (select the butterfly valve for
regulation, select the ball valve or gate valve for the switch);
Select the valve pressure grade; Select the valve pressure grade according to pipeline design
pressure. (PN10 PN16 PN25 PN40);
Select the valve diameter;
Select the temperature range Operating temperature of medium determines the valve sealing type;
selecting good temperature grade can postpone the service life of valve;
Select the valve material: Select according to medium condition, whether determine the valve material
according to corrosivity;
Select the valve sealing type: Rubber sealing, fluorine rubber sealing, graphite sealing, hard alloy
sealing, and etc. (with different sealing types, service life of valve is different; sealing type also determines
the valve leakage);

272

XINXING PIPES

Xinxing Ductile Iron Pipes Technical Manual

Xinxing Ductile Iron Pipes Technical Manual

273

Anda mungkin juga menyukai