Instrumentation and Instrumentation Control Cables,


Thermocouple Extension and Compensating Cables

The Quality Connection

Table of contents

Part I

Preface

Page

Introduction

Page

1.1

The EN 50288-7 standard

Page

1.2

The advantages

Page

1.3

The product programme

Page

1.3.1 Customised types

Page

1.3.2 Standard types

Page

1.4

Structural summary

Page

The customised types

Page A3

2.1

Introduction

Page

2.2

General

Page A3

A3

2.2.1 Applications

Page

A3

2.2.2 Constructions

Page

A3

2.3

Design options and selection criteria for cable elements

Page

A4

2.3.1 Conductor

Page

A4

2.4

Insulation

Page A5

2.4.1 Insulation materials

Page A5

2.4.2 Radial thickness of insulation

Page A5

2.5

Cabling elements

Page

A6

2.6

Cabling assembling

Page

A5

2.7

Screening

Page

A7

2.7.1 Design

Page A7

2.7.2 Internal interference

Page A7

2.7.3 External interference

Page A8

- Screening in the LF-range

Page A8

- Screening in the HF-range

Page A9

2.8

Plastic sheath

Page A10

2.8.1 The different types

Page A10

2.8.2 Inner sheath and bedding

Page A10

2.8.3 Multi layer sheath

Page A10

2.8.4 Overall sheath

Page A10

2.8.5 Sheath Materials

Page A11

- Polyvinylchloride (PVC)

Page A11

- Halogenfree flame retardant compounds (LSZH)

Page A11

- Polyethylene (PE)

Page A12

2.9

Chemical and/or environmental protection

Page A13

2.10 Armour

Page A14

2.11 Chart EN 50288-7

Page A16

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

...

 

Table of contents

The standard types

Page BI3

3.1

Introduction

Page BI3

3.2

Structure of the product programme standard types

Page BI3

3.3

Presentation of product data

Page BI3

3.4

Product data sheets

Page BI3

Group 1: ICON instrumentation cables acc. to EN 50288-7

Page

B1

Common types
300 V and 500 V

Technical data


Construction: unarmoured/armoured types


Construction: lead-/multi layer- sheathed armoured types

Electrical data 300 V


Electrical data 500 V

Page
Page
Page
Page
Page
Page

B1
B2
B3
B4
B5
B6

Halogen-free, flame retardant types



Technical data

Construction

Electrical data 300 V

Electrical data 500 V

Page B7
Page B8
Page B9
Page B10
Page B11

300 V and 500 V





Fire resisting (CI), flame retardant types



Technical data

Construction

Electrical data

500 V


Page
Page
Page
Page

B13
B14
B15
B16

Common types
500 V

Technical data


Construction: unarmoured/armoured types


Construction: lead-/multi layer- sheathed armoured types

Electrical data

Page
Page
Page
Page
Page

C1
C2
C3
C4
C5

Halogen-free, flame retardant types



Technical data

Construction

Electrical data

Fire resisting (CI), flame retardant types

Technical data

Construction

Electrical data

500 V


Page B7
Page C8
Page C9
Page C10

500 V


Page
Page
Page
Page

C11
C12
C13
C14

Page
Page
Page
Page
page

D1
D2
D3
D4
D5

Group 2: ICON instrumentation control cables acc. to EN 50288-7

Group 3: ICON extension and compensating cables acc. to EN 50288-7


Common types
300 V

Technical data


Construction: unarmoured/armoured types


Construction: lead-/multi layer- sheathed armoured types

Electrical data



KERPEN GmbH & Co. KG

...

09.2006 Printing errors excepted. Subject to alterations

Table of contents

Halogen-free, flame-retardant types



Technical data

Construction

Electrical data

300 V


Page
Page
Page
Page

D7
D8
D9
D10

Appendix
I. Standards for thermocouple extension & compensating cables
Table 1: Temperature ranges and tolerances of conductors

Colour codes ofinsulations and outer sheaths

Page E2

Table 2: Electrical characteristics of conductors

Page E3

Table 3: Loop resistance of conductors at 20 C

Page F3


II. Colour codes

Colour codes of instrumentation


and instrumentation control cables acc. to EN 50288-7

Page

E4

III. Common test methods for cables under fire conditions


Reaction to fire

Page E5

Resistance to fire

Page

E5

IV. Identification of instrumentation, (instrumentation) control and


thermocouple extension and compensating cables

Indication

Page

E6

Abbreviation code

Page

E6

Type of cabling elements

Page

E7

Indication examples

Page

E7

E8


V. Tables
Table 4: Conversion of general units

Page

Table 5: Conductor comparison AWG - metric

Page E9

ICON instrumentation cable


Flame retardant, sunlight resistant
Multi-pair, PVC insulation, individual & overall screen,
Lead sheath, armour, PVC sheath

Page E10

Cable programme

Page E12

VI. Example of individual product documentation

Note: KERPEN GmbH & Co. KG can not be held responsible in any form whatsover for any information provided by this
publication.
Issue 20060926

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 



KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Preface

This is not just a catalogue. It is what you have been looking for - a
product guide to choosing the design you need for your project, plant or
application ....
... CREATED TO PROVIDE YOU with
the CABLE SOLUTION you need.
The European Standard EN 50288-7 is the first ever standard for instrumentation and control cables to address the entire range of demands
and reqirements of general and specific industrial cable applications.
In contrast to the existing official regulations and specifications, the new
standard covers the huge variety of cable designs used in todays global
business. The meaningful and comprehensive (but nevertheless standardized) range of different versions in terms of
design and materials used allows you to select
cable designs which comply with the standard
but still meet the requirements of the application.
The new standard will be complemented by European standards for materials and testing. These
standards do not exist as yet, so we shall refer to
IEC standards or national standards here.
On the solid basis of many years of experience
in international business (either project-oriented
or geared to the site requirements of the customers) in conjunction with the new standard, we have defined a
very wide product range designed to meet all your field-driven
product requirements.
We have selected and elaborated a product programme designed to cover all usual applications. The diversity of the environmental, electrical, mechanical, installation and safety requirements produces a need for an extensive
range of products. This first section covers all
necessary information on product families. Information on specific types will be provided on
request or via other media.
The extremely systematic organisation of this
guide to the various product families will allow
you to select your product to match your application and meet your requirements with maximum
efficiency.

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 

1. Introduction
1.1 The EN 50288-7 standard
The European standard EN 50288-7 published in September 2005 is
the first ever standard governing instrumentation cables for onshore
applications to have been prepared by an established international
standardisation body.

The following features distinguish this standard from the wide variety of existing product specifications:


it complements the relevant standards for materials and testing


it includes a wide range of design options
it effectively matches design regulations with test requirements

This standard thus enables the user to convert all demands with regard to systems, security, the environment, climate and installation
into appropriate products in an efficient way
The standard will have to be implemented in the form of national
standards by all Cenelec members (28 countries at present). Its
future significance is underlined by the fact that all present national
standards which conflict with the EN standard will have to be withdrawn after a certain transitional period (April 2008).
This standard also meets the requirements of the European Low
Voltage Directive.

1.2

The advantages

The application of this standard offers a number of advantages:


it was prepared by a recognized standardization body

it represents the state of the art throughout

it is available to everyone everywhere

it specifies products easily, quickly, clearly and without ambiguity

it includes a wide range of design options

It thus allows consultants, engineers, manufacturers and others to save time and money when

preparing specifications

dealing with inquiries, offers and orders

organizing product-programmes

Summary:
The application of this standard should become as logical and widespread as the application of the IEC 60502
standard for power cables.



KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Introduction
1.3 The product programme
The EN 50288-7 standard does not comprise specific products; instead it merely describes the individual cable
elements and their design (including options and the relevant rules), defines materials, dimensions and test requirements and cites the relevant standards.
On the basis of more than thirty years of experience in the international instrumentation cable business, KERPEN
has seized the opportunity and defined the EN 50288-7-based ICON product programme, which consists of two
sections:
Customised types and Standard types

1.3.1

Customised types

The Customized types section gives an overview of the entire range of design options covered by the standard
and adds explanations and selection criteria. It thus provides optimum support for selecting and specifying products required. Product documentations and quotations are available on request.

1.3.2

Standard types

The Standard types section is an extract from the Customized types section. It presents a comprehensive
range of products of the main types used in the market. A few thousand products are described in detail complete
with geometrical data and design data, information on mechanical, thermal and flame behaviour properties and
electrical data. For this information please see the attached CD-ROM.

1.4 Summary of the structure

Standard types

Customised types

- Thousands of conventionally used


products

- Technical basis for entire market


demand

- Complete technical documentation

- Allows specifications and products


to be tailor-made

- Available immediately

- Clear and unambiguous design rules

- Quotes provided rapidly

- Fast and flexible handling of products

- Cost-effective

- Documentation on request

- Short delivery time


- Modular design concept

Well-known quality from reliable project partners based on the international safety regulations

The ICON product programme also covers instrumentation cables complying with UL standards UL13, 2250 and
1277 as well as bus cables according to PNO and FFO.
KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 



KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

The Customised Types

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 A1

 A2

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

The customised types

2.1 Introduction
The Customized types section gives a summary of the entire range of design options and design rules concerning the EN 50288-7 standard. A summary of it is shown in chart form on the last page of this chapter.
The contents of the standard (text in italics) are complemented by explanations and selection criteria to help you
to find the best possible design solution.

2.2 General remarks


2.2.1

Applications

The standard covers instrumentation cables as well as thermocouple extension and compensating cables suitable
for connecting instruments and control systems for the purposes of analogue and digital transmission.
The cables are not designed for use with power supplies and should not be connected directly to the mains or to
other low-impedance power sources.
Valid local and national regulations must be taken into account during installation.
The standard must be used in connection with the referenced standards for materials and testing.

2.2.2 Designs
The cable can contain cores, pairs, triples or quads as cabling elements; they can have individual or overall
screening and optionally include armouring and/or additional layers for moisture resistance or environmental protection. The maximum rated voltages of the cables are 300 V and 500 V.

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 A3

The customised types


2.3 Design options and selection criteria for cable elements
2.3.1 Conductor
2.3.1.1 Conductor for instrumentation cable

Plain and metal coated copper conductors acc. to EN 60228 (IEC 60228)

Class 1 (solid), class 2 (stranded) and class 5 (flexible)

Sizes: 0.5 mm up to 2.5 mm

Criteria for the choice of conductor design and size are

the DC-resistance

the connection technology used


(including crimping, clamping, soldering, wire wrap and termi-point)

the flexibility requirements

the diameter

the environmental conditions

7-strands conductors are used in most cases.

2.3.1.2 Conductor for thermocouple extension and compensating cable


conductor material acc. to the requirements of the HD 446.1 (IEC 60584-3); 


see appendix 1, table 2

design: solid, stranded or flexible

sizes: 0.5 mm up to 1.5 mm

Criteria for the choice of type, design or size of conductor are:

the type of thermoelement used

the E.M.F-tolerances

the flexibility

Solid conductors are used in most cases.

 A4

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

The customised types


2.4 Insulation
2.4.1

Insulation materials

The insulating materials used include:






polyvinylchloride
polyethylene
polypropylene
halogen-free, flame retardant compound
cross-linked polyethylene

PVC
PE
PP
HFRC
XLPE

EN 50290-2-21
EN 50290-2-23
EN 50290-2-25
EN 50299-2-26
EN 50290-2-29

The most widely used insulating material today is polyethylene, followed by polyvinylchloride and cross-linked
polyethylene. Other materials such as materials resistant to high temperatures, polypropylene and foamed materials are used for special purposes only.
Selection criteria for insulation materials are

electrical transmission properties

limited operating temperatures

The following criteria can also be significant in certain special cases:


flame behaviour

suitability for special connection techniques

resistance to oil and gas

resistance to radiation

compatibility with filling compounds

Table 1: Properties of the most important insulating materials


Properties
Permittivity
Spec.volume resistance
at 20C

Polyvinylchloride
PVC

Cross linked
polyethylene

47

2.3

2.3

x cm

1014

1016

1016

70 C 1)

70 C 2)

90 C

stiff, tends to become brittle

good

good

self-extinguishing

inflammable

inflammable 3)

max. operating temperature


Behaviour at low temperature
Flammability
2)



3)

Heat resistant modified PVC for temperatures limited to 90 C and 105 C


80 C for high-density polyethylene HDPE
Also with self-extinguishing characteristic

2.4.2

Radial thickness of the insulation

1)

Polyethylene
PE

Two values must be considered with reference to the radial thickness of the insulation:

the minimum radial thickness

the nominal radial thickness

The minimum radial thickness of the insulation is defined in the standard. The measured radial thickness of the
insulation must not fall below the defined values at any point.
The nominal radial thickness of the insulation is a design value defined by the manufacturer to guarantee the
specified electrical transmission properties. The nominal thickness is thus a reference value only and will not be
dealt with here. Depending on the conductor size, the nominal thickness exceeds the minimum thickness by approx. 0.05 and 0.1 mm.
KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 A5

The customised types


2.5

Cabling elements

Cabling elements according to the standard are cores, pairs, triples and quads.
A core is an insulated conductor


A pair consists of two twisted cores which form a line
circuit

A triple consists of three twisted cores which form line
circuits with one another

A quad consists of four twisted cores in which the diametrically opposed cores form a line circuit

The length of lay of a part, triple or quad, must not exceed

150 mm for conductor size 2.5 mm

100 mm for conductor sizes 1.5 mm or

To keep internal interference of cabling elements pairs, triples or quads as low as possible, adjacent elements
have different lengths of lay.

2.6

Cable assembly

The cable elements must be assembled in concentric layers to form the cable core either

directly or

in the form of units

Units consist of a certain number of cores, pairs, triples or quads.


The direction of lay of successive layers of multi layer cables changes from layer to layer. This measure also contributes to the mutual decoupling of unScreened pairs, triples or quads from each other.

 A6

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

The customised types


2.7 Screening
2.7.1 Design
Screening can be either screening of individual cable elements and/or an overall screening. Screening measures
according to the standard are listed below:

plain or coated copper braid with 


a minimum filling factor of 0.6

a combination of plastic-laminated metal foil 


and a plain or coated copper braid with a
minimum filling factor of 0.3

plastic-laminated metal foil with 


a minimum overlap of 20 %, 
a drain wire in direct contact with the metallic side of the foil and a laminated sheath
(for overall screening only).

Screening measures must be provided in order to reduce or prevent possible interference such as

cross-talk from adjacent line circuit in the cable itself or

externally induced inference from sources outside the cable.

2.7.2

Internal interference

The only significant factor for Screening against internal interference is the capacitance (unbalanced) between the
cabling elements. Magnetic interference can be disregarded here.
Precautions used for reducing and to avoiding internal interference are

different length of lay of the various cabling elements (see 2.3) or

individual screening of the various cabling elements

Individual screening usually consists of plastic-laminated aluminium foil applied so as to overlap helically and a
copper drain wire in continuous contact with the metallic side of the foil.
An at least 20 % overlap of the foil guarantees 100 % coverage of the cabling element even in small bends.

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 A7

The customised types


2.7.3

External interference

Screening against external interference has to take the influence of both electric and magnetic interference into
account and make a distinction between LF and HF fields.
The design of the required screen depends on the type and strength of interference.

2.7.3.1 Screening in the LF-range


For screening in the LF-range - i.e. in the range of frequencies of up to 10 kHz - the influence of both electric and
magnetic interference can be examined separately. Interference from electric fields can be virtually disregarded if
conductive screens are used; the lower the dc resistance, the better the screening effect; however, care must be
taken to ensure a high degree of coverage as the electric field may otherwise affect the cable core.
Screening against LF magnetic interference requires the use of magnetic materials such as steel wires or (even
better) tapes.
Materials of high permeability should be used for high levels of screening.
The measure of the effect of the screening in the LF range is the reduction factor. This is the ratio of the interference voltage with a screen to the interference voltage without a screen and is calculated according to the following
formula:


r
=
c

RO

(RO + RE)2 + (LM + LE)

with
rc = reduction factor
The lower the rc the better the screening effect.

RO

dc resistance of screen in

/km

RE

dc resistance of earth loop in


(normally evaluated as 0.05 /km)

/km


LM

internal screen inductance in


(this value can be disregarded for non-magnetic screens)

H/km


LE

external inductance of the earth loop in


(the usual value is 0.002 H/km)

H/km

angular frequency (2 f) in Hz

 A8

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

The customised types

2.7.3.2 Screening in the HF-range


Screening in the HF range is based on energy losses due to electromagnetic interference caused by absorption
and reflection in or on the Screening material.
The measure for the effect of screening in the HF range is the coupling resistance, which is defined as follows


rc =

induced interference voltage in the disturbed system


rc

current in the disturbing system

coupling resistance

The lower the rc the better the screening effect.


The coupling resistance depends on the frequency. The typical curve of the coupling resistance is shown below.

rc ()

f (Hz)

Requirements for effective screening in the HF-range are basically a low DC resistance and maximum coverage
of the screen. Hre is a selection of screen designs (the screening effect increases from top to bottom):




plastic laminated aluminium foil


laminated aluminium tape overlapping longitudinally
optimized copper braid of high density
copper tape, lapped or overlapping longitudinally
copper tubing

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 A9

The customised types


2.8 Plastic sheaths
2.8.1

The different types

the outer sheath


providing the protection of the cable from outside

the inner sheath


applied under a metallic protection and - optional - under a lead sheath


 the multi layer sheath
a special type of inner sheath; an alternative possibility for a lead sheath 
as environmental and chemical protection

the bedding
a separation sheath applied between a lead sheath and a metallic protection 
(may also consists of plastic tapes)

The standard defines 4 different types of extruded plastic sheaths

The following materials can be used for the inner and outer sheath and for the bedding, :

PVC

acc. to EN 50290-2-22

polyethylene

acc. to EN 50290-2-24

halogen-free flame retardant compound

acc. to EN 50290-2-27

2.8.2

Inner sheath and bedding

maximum and minimum temperatures during operation

flame behaviour

halogen content

The main function of the bedding and/or an inner sheath is to protect the cable core from mechanical stress and
moisture. Here are some additional criteria which must be considered when the type of material is determined:

2.8.3 Multi layer sheath

A multi layer sheath consists of a longitudinal plastic-coated aluminium tape, a layer of high-density polyethylene
bonded to the aluminium tape and an additional layer of polyamide.
The high-density polyethylene must be in accordance with EN 50290-2-24, the material specification for polyamide
is in the discussion stage at present.

2.8.4

Overall sheath

way of laying i.e.

mechanical stress

environmental conditions

climatic conditions

demands made on fire behaviour and flame retardancy

demand made on colouring and marking

The conditions prevailling during transportation and storage, installation and operation determine the type of material to be used. The following criteria must be taken into account in the selection of a suitable sheath material:

 A10

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

The customised types


2.8.5

Sheathing materials

2.8.5.1 Polyvinylchloride (PVC)


As a result of its great value for money, PVC has been the
most widely used sheathing material for instrumentation cables up to now. Its great ability to be modified allows a selective adaptation of desired properties which makes it suitable
for a wide range of applications.
PVC is suited for indoor and outdoor laying in dry and wet
locations, in conduits and for direct burial.
Its maximum permissible temperature ranges from 70C for
standard types to 90C or 105C for special heat-resistant
types. The recommended minimum temperatures for these
types are-5C for installation and -0C for operation.
Special cold resistant types permit significantly lower temperature during operation and installation. The maximum
permissible temperature is 70C or 90C.
PVC is a flame-retardant, self-extinguishing material. Its flame retardancy can be imcreased to higher levels. The
emission of halogen acid gas and the smoke density in the event of fire can be reduced in the same way. Most
PVC-compounds are resistant to oil and solvents to a certain degree. Specially designed types are recommended
for more stringent requirements.
PVC can be supplied in a wide range of colours. When exposed to sunlight, the colours fade, but this has no effect
on the function. All sheathing compounds are resistant to sunlight.

2.8.5.2 Halogen-free flame retardant compound (LSZH)


Starting from a low level, the use of halogen-free flame-retardant compounds has increased steadily over the last
ten years as a result of the growing need for halogen-free flame-retardant cables as a special measure to protect
persons and/or important material assets.
In the event of fire, halogen-free flame-retardant compounds are distinguished by characteristics such as the following:

reduced flame propagation

reduced acidity and toxicity of gases

reduced smoke density

no halogen acid gases

Halogen-free flame-retardant compounds are suitable for indoor and outdoor application. Special compounds
with reduced water absorption are recommended for direct burial. The maximum temperature limits of the types
defined are 70C and 90C. The recommended minimum temperatures are -5C for installation and -30C for
operation.
Standard halogen-free flame-retardant compounds are only partly resistant to oils and solvents. Standard compounds meet the requirements of the oil resistance test according to ICEA S82-552. Special types must be used
for more stringent requirements.
Most halogen-free flame-retardant compounds can be supplied in a wide variety of colours. When exposed to
sunlight, the colours fade, but this has no effect on the function.
KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 A11

The customised types


2.8.5.3 Polyethylene (PE)
Polyethylene sheaths can be made of LDPE, MDPE and HDPE materials (low-density, medium-density and highdensity polyethylene).
The lack of flame-retardancy restricts the use of polyethylene sheathes to direct buried cables.
As a result of its excellent mechanical properties such as its high
tensile strength, its high resistance to abrasion, its hardness and
its extremely low water absorption, polyethylene is the ideal material for this application.
The maximum permissible temperature is 70C for LDPE and
MDPE and 80C for HDPE. As a result of its outstanding resistance to low tempeartures, cable insulated and sheathed with
polyethylene can be installed down to temperatures of -20C.
The material becomes harder in proportion to the temperature,
however. The bending resistance of the cable increases, with the
corresponding negative effects on handling during installation.
Polyethylene stands out through its high resistance to oil and
chemicals. This and the mechanical properties increase from
LDPE to HDPE.
As mentioned above, polyethylene is not flame-retardant. When ignited, it tends to drip and burn on after removal
of the flame. For this reason, polyethylene sheathing should not be used for indoor applications.
Polyethylene must stabilized against UV using soot. This is why the outer sheath is black in colour.

 A12

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

The customised types


2.9 Chemical and/or environmental protection
If there is a risk of oils and chemicals affecting cables after installation, protective measures must be taken.
The grading of the possible effects on the cables is determined by the nature, condition and quantity of the effecting medium, the duration of immersion and the temperature. In certain cases, plastic sheaths afford adequate
protection, but more stringent measures must usually be taken in order to avoid negative effects on the long-term
functioning of the cables involved.
For directly buried cables in particular, the EN standard recommends the following structural elements:
a) Lead sheath
Lead sheathes are the best protective measure against oils and chemicals. They are especially recommended
where soils are heavily polluted.
Lead alloy sheathed types should be used where there are high
mechanical loads due to vibration.

b) Multi layer sheath


Multilayer sheaths consist of a longitudinal plastic-coated aluminium foil, a layer of high-density polyethylene and an additional
covering of polyamide. The aluminium foil is bonded inside the
overlap and with the inner surface of the HDPE sheath.
Multilayer sheaths are an adequate alternative to lead sheaths
for a large number of applications. Compared to cables with lead
sheaths, those with multilayer sheaths are smaller and lighter,
thus allowing longer handling lengths.

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 A13

The customised types


2.10 Armour
If an armour is specified, it should be selected from the types listed below:

Galvanised round steel wire armour



The wire diameter depends on the cable diameter
under armour, min. diameter 0.9 mm


G
 alvanised flat steel wire armour

The minimum is wire diameter; this armour shall be
used for cables, where the diameter under armour is
> 15 mm

S
 ingle or double layer of steel or brass tapes

The minimum thickness of a tape shall be 0.2 mm 
for steel and 0.075 for brass.


M
 etal braid

The minimum filling factor must be 0.57 
(corresponding optical coverage 81.5 %), 
the minimum wire diameter 0.3 mm.

The choice of the most suitable type of armour depends on the demands of installation and operation. In addition,
local and legal regulations must be complied with.
The most important selection criteria are:

maximum expected tensile load


and minimum required load-bearing capacity during installation
and/or operation

maximum expected pressure and tensile load after laying

protection against attack by rodents

minimum required bending radius

protection against external interferences

 A14

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

The customised types

The types of armour listed above are characterized by the following features:
Galvanised metal wire braid
Lightweight armour of galvanised steel or plain or
tinned round copper wire; suited for small tensile
and pressure loads; permits the smallest bending
radii of all armour types; mainly used for small cable
diameters.
Galvanised steel tapes

Applied as single- or dual-layer armour with 100%
covering of the cable assembly; excellent protection
against pressure and impact loads; not suitable for
tensile loads; very good protection against rodents;
of all types of armour listed, they provide the best
inductive protection.
Brass tapes
These are applied in the same way as steel tapes;
especially recommended to prevent attack by rodents and termites.
Galvanised flat steel wires
Good protection against pressure and impact loads; suitable for high tensile loads; the least flexibile
of all types of armour listed.
Galvanised round steel wire
Coverage: more than 90 %; very good mechanical protection against pressure and impact loads,
suitable for high tensile loads, good protection against rodents; the type of armour used most frequently for direct buried cables.

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 A15

 A16

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Wet: petrojelly lling compound

Dry: swellable tapes, and/or cords,


swellable powder

Moisture barriers

With or without moisture barriers

Directly or in units in concentric layers

Assembling

Combination of a braid and a foil

Plain or coated metal braid

Plastic laminated metal foil with drain wire

Individual screen

Cores, pairs, triples, quads

Cabling elements

Additional materials under preparation

Multicore types

Assembling of
cabling elements
+/0 moisture barriers

Twisting of pairs,
triples and quads

Screening of
cabling elements

Overall screen

Petrojelly acc. to EN 50290-2-29

Moisture barriers

Wrappings of non hygroscopic tapes


interstitial llers, where neccessary

Assembling

Filling factor of the braid 0.6 and 0.3


resp. when combined with a foil

Overlapping of the foil: min. 20%

Individual screen

Identication: numbered cores or tapes


or acc. to IEC 60189-2 or IEC 60708-1

Max. length of lay:


up to 1.5 mm
100 mm
2.5 mm
150 mm

Cabling elements

Min. insulation thickness depending on


voltage rating and conductor size

Concentricity of insulation: min. 0.75

Acc. to EN 50290-2-21, 23, 25, 26 a. 29

PVC, PE (solid and foam), XLPE, PP (solid and


foam), Halogenfree, ame retardant compounds

Max. conductor resistance for multi-element


cables (beside cores):
Standard value + 2%
Insulation

Insulation

Conductor

Acc. to EN 60228, class 1, 2 or 5

Conductor

Construction Details
Reference Standards

Insulation

*(for thermocouple & extension cables see to IEC 60584-3)

Conductor shape: solid, stranded or exible

Conductor sizes: 0.5 mm up to 2.5 mm

Copper, plain or tinned

Conductor *

Design Options

Voltage rating 300 V; 500 V


Type Options

Multi-Element Metallic Cables for Analogue and Digital Communication and Control Systems

The European Standard EN 50288-7

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 A17

Screening of cable
element assembly

Bedding

Additional materials under preparation

PVC, PE, or halogenfree, ame retardant


compounds

Outer sheath

Metal braid (Q)

Single or double layer of steel or brass tapes (B)

Single layer of round steel wires (SWA)

Armour

Helically applied tape (s)

Armouring

Outer sheath

Thickness for armoured types:


0.028 x D + 1.1 mm (min. 1.3 mm)
D = diameter under outer sheath

Thickness for unarmoured types:


0.04 x D + 0.7 mm (min. 0.8 mm)

Acc. to EN 50290-2-22, 24 and 27

Outer sheath

Q: Filling factor: min. 0.57,


wire diameter min. 0.3. mm

B: min. thickness: 0.2 mm a. 0.075 mm resp.

SWA: acc. to EN 10257-1; min. 0.9 mm

Armour

Thickness: depending on diameter under


bedding; min.1.0 mm

Bedding
According to EN 50290-2-22, 24 and 27

Thickness of polyamid covering:


min. 0.3 mm

b) Multi layer sheath

Thickness: 0.03 x D + 0.7 mm (min. 0.8 mm)


D: Diameter under lead sheath

According to EN 50307

a) Lead sheath

Thickness: 0.04 x D + 0.7 mm (min. 0.8 mm)


D: Diameter under inner sheath

Optional under lead sheath

According to EN 50290-2-22 and 27

Extruded layer of PVC, PE or halogenfree,


ameretardant compounds or

Multilayer sheath

Lead sheath

Inner sheath

Inner sheath

Bedding

Laminated HDPE sheath and an


additional polyamid covering

b) Multi layer sheath

or

a) Lead sheath

Chemical and/or environmental protection

Additional materials under preparation

PVC, PE, halogenfree,


ame retardant compounds

Inner sheath

Laminated sheath

Combination of a braid and a foil

One or both side laminated aluminium tape


longitudinally overlapped, bonded to the inner
surface of an extruded sheath, thickness of
alum. tape: min. 0.15 mm without coating

Filling factor of the braid > 0.6 and > 0.3


resp. when combined with a foil

Plain or coated metal braid

Overlapping of the foil min. 20%

Plastic laminated metal foil with drain wire

Overall screen

Overall screen

 A18

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

The Standard Types

Please find current available data sheets for standard products on this CD-ROM.

System requirements: Windows 9x/Windows NT JavaScript enabled


optimised for 800 x 600 pixels, 256 colours, Internet Explorer 6.0
Insert disc to launch CD. The CD starts automatically.
No files will be installed at the local system.
For more information please visit www.KERPEN.com

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 BI1

 BI2

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

3 The standard types


3.1 Introduction
The part standard types presents the most customary types out of the customised types It is an excerpt of it.
The programme covers some thousands different cables, thorough described on the following pages and in detail
on the CDROM attached. The product information in this chapter are presented in a systematically structured
condensed form. So, you find an optimum overview and an optimal product selection guide.

3.2 Structure of the product programme standard types


The product programme is arranged within three main groups:


instrumentation cables


(instrumentation) control cables


thermocouple extension
& compensating cables

cabling elements: pair and triple


cabling element: core
cabling elements: pair

Pairs and triples may be with or without individual screen.

Each main group is derived into three subgroups:





common types (PVC-sheathed)

halogen-free, flame-retardant types (LSZH-sheathed)

fire-resisting, flame-retardant types (LSZH-sheathed)

Each sub-group describes different product-families (2 up to 4). Product-family stands for a product line with a certain insulation material, containing unarmoured and armoured products; and for the subgroups common types
armoured versions with chemical environmental protection (lead or multi-layer sheath) additionally. The miscellaneous insulation materials offers options for optimising electrical, thermic or other relevant product properties.

3.3 Presentation of product data


The product data are headed:



Technical data





Construction

Electrical data

Contains information on application range, laying, temperature


limitations, bending radius, flame behaviour, and others.
Describes the design of the cables
Contains the electrical properties of the described products.

3.4 Product data sheets


The product descriptions are completed by product data sheets recorded on the attached CD-ROM. An example
of a product data sheet is shown on page E10 ff. The data sheets also itemise the usual geometrical data of every
individual product.

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 BI3

 BI4

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Group 1:

Instrumentation Cable acc. to EN 50288-7

Common Types

300 V and 500 V

Instrumentation Cable

Common Types
300 V and 500 V

Halogen-free,
flame retardant types
300 V and 500 V

Fire resisting (CI),1)


flame retardant types
500 V

plain stranded copper conductor,


pairs and triples,
individual
and/or
overall static screen

plain stranded copper conductor,


pairs and triples,
individual
and/or
overall static screen

plain stranded copper conductor,


pairs and triples,
individual
and/or
overall static screen

PVC- or PVCw- or PE- or XLPE(70C) (105C) (70C) (90C)


insulated/PVC-sheathed

PE- or XLPE(70C) (90C)


insulated/LSZH-sheathed

Mica/XLPE- or Silicone(90C) (90C)


insulated/LSZH-sheathed

unarmoured

armoured

unarmoured

armoured

unarmoured

armoured

Lead sheathed or
Multi layer sheathed, armoured

1)

gen. to EN 50288-7

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 B1

Instrumentation Cable

acc. to EN 50288-7

Common Types

300 V and 500 V

Single & Multi pair and Multi triple, individual and/or overall screen, PVC-sheath
unarmoured
armoured,
with chemical protection, armoured

Technical Data
Type of insulation/
sheath
Type of cabling
elements

PVC/PVC

PVCw/PVCw

PE/PVC

XLPE/PVC

Pair, Triple, PiMF, TiMF

No. of cabling elements

1, 2, 4, 5, 6, 8, 10, 12, 16, 20, 24

Conductor sizes

0.5 mm, 0.75 mm, 1.0 mm, 1.3 mm, 1.5 mm

1. Unarmoured types

RE-Y(St)Y-fl

Laying

RE-Yw(St)Yw-fl

RE-2Y(St)Y-fl 1)

RE-2X (St)Y-fl

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations

Bending radius

7.5 x cable

2. Armoured types

RE-Y(St)YSWAY-fl

Laying

RE-Yw(St)YwSWAYw-fl

RE-2Y(St)YSWAY-fl

RE-2X(St)YSWAY-fl

Recommended for outdoor installation, on racks,


trays, in conduits, in dry and wet locations, for direct burial

Bending radius

10 x cable

3. Armoured types with


chemical protection
a)
Lead sheathed

RE-Y(St)YMYSWAY-fl

--

--

--

--

--

b)
Multi layer sheathed
Laying

RE-2X(L)2Y4YSWAY
2) 3)

Recommended for direct burial, especially in presence


of oil and aggressive chemical substances

Bending radius
Temperature range
during operation
during installation

RE-2X(St)YMYSWAY-fl

15 x cable

- 30 C up to 70 C
- 5 C up to 50 C

- 30 C up to 105 C
- 5 C up to 50 C

- 30 C up to 70 C
- 5 C up to 50 C

- 30 C up to 90 C
- 5 C up to 50 C

Reaction to fire

Flame propagation
a) Test on single cable
b) Test on bunched cables

IEC 60332-1-2
IEC 60332-3 part 24 (Cat. C), (excluded types with multi layer-sheath)

Sunlight resistance

UL 1581 Section 1200

Oil resistance
Application

ICEA S-82-552
For transmission of analogue and digital signals in instrument and control systems; allowed
for use in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for direct
connection to low impedance sources, e.g. public mains electricity supply

Also with increased thickness of outer sheath (Yv)


Also with HDPE outer sheath; in this case Tests Reaction to Fire are not passed
3)
Max. operating temperature 80 C
1)
2)

 B2

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Instrumentation Cable

acc. to EN 50288-7

Common Types

300 V and 500 V

Single & Multi pair and Multi triple, individual and/or overall screen, PVC-sheath
unarmoured
armoured,
with chemical protection, armoured

Construction
Product type

unarmoured types

Conductor
cross-section

armoured types

Plain annealed copper; 7 stranded acc. to EN 60228, Class 2


mm

0.5
7 x 0.3

conductor design mm

0.75
7 x 0.37

Insulation materials

Cabling element 2)
without ind. screen
with ind. screen

1.3
7 x 0.49

1.5
7 x 0.53

Cross linked polyethylene XLPE or


Polyethylene PE or
Polyvinylchloride PVC or
Polyvinylchloride heat resistant PVCw

Pair, Triple
PiMF, TiMF

Individual screen

1.0
7 x 0.43

Aluminium/plastic-tape over solid tinned copper drain wire, 0.6 mm


plastic tape under and above screen

Wrapping

at least one plastic tape above cable core

Overall screen

Aluminium/plastic-tape over tinned copper drain wire 0.5 mm / 7 x 0.3 mm

Inner sheath

--

PVC and PVCw resp. , black

Armouring

--

Galvanized steel wire armouring; wire


depending on cable- under armouring, at
least 0.9 mm

Outer sheath 1)
Colour

PVC and PVCw resp. ,


black or blue for intrinsically safe systems
ICON by KERPEN Instrumentation Cable EN 50288-7
Rated voltage RP3) CE Length Marking

Marking

Also with increased thickness of outer sheath (Yv) for PE-insulated, unarmoured types
Colour code of cabling elements: see appendix II
3)
RP = Reduced flame propagation
1)
2)

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 B3

Instrumentation Cable

acc. to EN 50288-7

Common Types

300 V and 500 V

Single & Multi pair and Multi triple, individual and/or overall screen, PVC-sheath
unarmoured
armoured,
with chemical protection, armoured

Construction
Product types

Lead sheathed, armoured types

Conductor
cross-section

Multi layer sheathed, armoured types

Plain annealed copper acc. to EN 60228, Class 2


0.5
7 x 0.3

mm

conductor design mm
Insulation materials

0.75
7 x 0.37

1.0
7 x 0.43

1.3
7 x 0.49
XLPE

PVC or XLPE

Cabling element 1)
without ind. screen

Pair, triple

with ind. screen

PiMF, TiMF

Individual screen

Aluminium/plastic-tape over tinned copper drain wire, 0.6 mm,


plastic-tape under and above screen

Wrapping
Overall screen

at least one plastic tape above cable core


Aluminium/plastic tape over tinned copper drain
wire 0.5 mm / 7 x 0.3 mm

see multi layer sheath

PVC

--

Lead sheath

--

PVC

--

--

Longitudinal one side plastic coated


aluminium foil over tinned copper drain
wire, 7 x 0,3 mm, high density polyethylene
sheath with an additional polyamide
covering. The aluminium foil is bonding
within the overlapping and with the inner
surface of the polyethylene sheath

Inner sheath

Metal sheath
Bedding

Multi layer-sheath

Galvanized steel wire; wire depending on cable- under armouring,


at least 0.9 mm

Armouring
Outer sheath
Colour
Marking

PVC
black

2)

 B4

PVC or PE (high density)


black

ICON by KERPEN Instrumentation Cable EN 50288-7 Rated Voltage RP2) CE Length


Marking

1)

1.5
7 x 0.53

Colour code of cabling elements: see appendix II


RP = Reduced flame propagation, excluded types with multi layer sheath

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Instrumentation Cable

acc. to EN 50288-7

Common Types

300 V

Single & Multi pair and Multi triple, individual and/or overall screen, PVC-sheath
unarmoured
armoured
with chemical protection, armoured

Electrical Data at 20 C
Properties

Character

Unit

nom.

mm

0.5

Conductor resistance

max.

/km

36.7

Insulation resistance
PVC / PVCw -insulation

min.

Mxkm

100

PE / XLPE -insulation

min.

Mxkm

5000

L/R Ratio

max.

H/

Inductance

max.

mH/km

Mutual capacitance
PVC / PVCw-insulation
Pair, Triple 1), 2)

max.

nF/km

150

160

max.

nF/km

190

200

max.

nF/km

75

85

max.

nF/km

115

115

max.

pF/
500m

500

V
V

1500
1500

300

Conductor sizes

PiMF, TiMF
PE / XLPE-insulation
Pair, Triple 1), 2)
PiMF, TiMF
Capacitance unbalanced 3)
Pair
Test voltage
Core/core
Core/screen

(Urms)
(Urms)

Operating voltage

(Urms)

max.

Values
0.75

25.0

1.0

18.5

25

1.3

1.5

14.2

12.3

40
1

1)

Values for cables with 1 element correspond to those for PiMF


and TiMF resp.
2)
Values for cables with 2 up to 4 elements + 20 %
3)
To apply only for PE, XLPE-insulated types
KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 B5

Instrumentation Cable

acc. to EN 50288-7

Common Types

500 V

Single & Multi pair and Multi triple, individual and/or overall screen, PVC-sheath
unarmoured
armoured
with chemical protection, armoured

Electrical Data at 20 C
Properties

Character

Unit

nom.

mm

0.5

Conductor resistance

max.

/km

36.7

Insulation resistance
PVC / PVCw -insulation

min.

Mxkm

100

PE / XLPE -insulation

min.

Mxkm

5000

L/R Ratio

max.

H/

Inductance

max.

mH/km

Mutual capacitance
PVC / PVCw-insulation
Pair, Triple 1), 2)

max.

nF/km

120

130

max.

nF/km

160

170

max.

nF/km

65

75

max.

nF/km

100

100

max.

pF/500m

500

V
V

2000
2000

500

Conductor sizes

PiMF, TiMF
PE / XLPE-insulation
Pair, Triple 1), 2)
PiMF, TiMF
Capacitance unbalanced 3)
Pair
Test voltage
Core/core
Core/screen

(Urms)
(Urms)

Operating voltage

(Urms)

max.

Values
0.75

25.0

1.0

18.5

25

1.3

1.5

14.2

12.3

40
1

1)

Values for cables with 1 element correspond to those for PiMF


and TiMF resp.
2)
Values for cables with 2 up to 4 elements + 20 %
3)
To apply only for PE, XLPE-insulated types

 B6

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Group 1:

Instrumentation Cable

acc. to EN 50288-7

Halogen-free, flame retardant types 300 V and 500 V

Instrumentation Cable

Common Types
300 V and 500 V

Halogen-free,
flame retardant types
300 V and 500 V

Fire resisting (CI),1)


flame retardant types
500 V

plain stranded copper conductor,


pairs and triples,
individual
and/or
overall static screen

plain stranded copper conductor,


pairs and triples,
individual
and/or
overall static screen

plain stranded copper conductor,


pairs and triples,
individual
and/or
overall static screen

PVC- or PVCw- or PE- or XLPE(70C) (105C) (70C) (90C)


insulated/PVC-sheathed

PE- or XLPE(70C) (90C)


insulated/LSZH-sheathed

Mica/XLPE- or Silicone(90C) (90C)


insulated/LSZH-sheathed

unarmoured

armoured

unarmoured

armoured

unarmoured

armoured

Lead sheathed or
Multi layer sheathed, armoured

1)

gen. to EN 50288-7

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 B7

Instrumentation Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

300 V and 500 V

Single & Multi pair and Multi triple, individual and/or overall screen, LSZH-sheath
unarmoured
armoured

Technical Data
Type of insulation/sheath

XLPE/LSZH

PE/LSZH

Types of cabling elements

Pair, Triple, PiMF, TiMF

No. of cabling elements

1, 2, 4, 5, 6, 8, 10, 12, 16, 20, 24

Conductor sizes

0.5 mm, 0.75 mm, 1.0 mm, 1.3 mm, 1.5 mm


RE-2Y(St)H

1. Unarmoured types
Laying

RE-2X(St)H

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations

Bending radius

7.5 x cable

2. Armoured types

RE-2Y(St)HSWAH

Laying

RE-2X(St)HSWAH

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations, for direct burial

Bending radius
Temperature range
during operation
during installation

10 x cable

- 30 C up to 70 C
- 5 C up to 50 C

Reaction to fire
Flame propagation
a) Test on single cable
b) Test on bunched cables
Test on gases evolved
during combustion:
a) amount of halogen acid
gas
b) degree of acidity of
gases
Measurement of smoke
density

IEC 60754-1 (0 %)
IEC 60754-2 (pH > 4.3, c < 10S/mm)
IEC 61034-2 (L.T.1) > 60 %)
ICEA S-82-552
For transmission of analogue and digital signals in instrument and control systems; allowed for use
in zone 1 and zone 2, group II, classified areas (IEC 79-14), not allowed for direct connection to low
impedance sources, e.g. public mains electricity supply.
Recommended for use as fire protection measure for people and important material assets.

1)

 B8

- 30 C up to 90 C
- 5 C up to 50 C

IEC 60332-1
IEC 60332-3 part 24 (Cat. C)

Oil resistance
Application

L.T. = Light Transmission


KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Instrumentation Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

300 V and 500 V

Single & Multi pair and Multi triple, individual and/or overall screen, LSZH-sheath
unarmoured
armoured

Construction
Product type

Unarmoured types

Conductor
cross-section

Armoured types

Plain annealed copper; 7 stranded acc. to EN 60228, Class 2


mm

0.5
7 x 0.3

conductor design mm

0.75
7 x 0.37

Insulation materials
Cabling element 1)
without ind. screen
with ind. screen

1.0
7 x 0.43

1.3
7 x 0.49

1.5
7 x 0.53

Polyethylene PE or
Cross linked polyethylene XLPE

Pair, Triple
PiMF, TiMF

Individual screen

Aluminium/plastic-tape over tinned copper drain wire, 0.6 mm


plastic-tape under and above screen

Wrapping

at least one plastic tape above cable core

Overall screen

Aluminium/plastic tape over tinned copper drain wire 0.5 mm / 7 x 0.3 mm

Inner sheath

--

LSZH , black

Armouring

--

Galvanized steel wire; wire depending on


cable- under armouring, at least 0.9 mm

Outer sheath
Colour

LSZH,
black or blue for intrinsically safe systems
ICON by KERPEN Instrumentation Cable EN 50288-7 Rated voltage
LSZH CE Length Marking

Marking

1)

Colour code of cabling elements: see appendix II

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 B9

Instrumentation Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

300 V

Single & Multi pair and Multi triple, individual and/or overall screen, LSZH-sheath
unarmoured
armoured
Electrical Data at 20 C
Properties

Character

Unit

Conductor sizes

nom.

mm

0.5

Conductor resistance

max.

/km

36.7

Insulation resistance
PE / XLPE -insulation

min.

Mxkm

L/R Ratio

max.

H/

Inductance

max.

mH/km

Mutual capacitance
PVC / PVCw-insulation
Pair, Triple 1), 2)

max.

nF/km

75

85

PiMF, TiMF

max.

nF/km

115

115

Capacitance unbalanced
Pair

max.

pF/500m

500

V
V

1500
1500

300

Test voltage
Core/core
Core/screen

(Urms)
(Urms)

Operating voltage

(Urms)

max.

Values
0.75

25.0

1.0

18.5

1.3

1.5

14.2

12.3

5000
25

40
1

Values for cables with 1 element correspond to those for PiMF and
TiMF resp.
2)
Values for cables with 2 up to 4 elements + 20 %
1)

 B10

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Instrumentation Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

500 V

Single & Multi pair and Multi triple, individual and/or overall screen, LSZH-sheath
unarmoured
armoured

Electrical Data at 20 C
Properties

Character

Unit

Conductor sizes

nom.

mm

0.5

Conductor resistance

max.

/km

36.7

Insulation resistance
PE / XLPE -insulation

min.

Mxkm

L/R Ratio

max.

H/

Inductance

max.

mH/km

Mutual capacitance
PVC / PVCw-insulation
Pair, Triple 1), 2)

max.

nF/km

65

75

max.

nF/km

100

100

max.

pF/500m

500

V
V

2000
2000

500

PiMF, TiMF
Capacitance unbalanced
Pair
Test voltage
Core/core
Core/screen

(Urms)
(Urms)

Operating voltage

(Urms)

max.

Values
0.75

25.0

1.0

18.5

1.3

1.5

14.2

12.3

5000
25

40
1

Values for cables with 1 element correspond to those for PiMF and
TiMF resp.
2)
Values for cables with 2 up to 4 elements + 20 %
1)

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 B11

 B12

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Group 1:

Instrumentation Cable

acc. to EN 50288-7

Fire resisting (CI), flame retardant types

500 V

Instrumentation Cable

Common Types
300 V and 500 V

Halogen-free,
flame retardant types
300 V and 500 V

Fire resisting (CI),1)


flame retardant types
500 V

plain stranded copper conductor,


pairs and triples,
individual
and/or
overall static screen

plain stranded copper conductor,


pairs and triples,
individual
and/or
overall static screen

plain stranded copper conductor,


pairs and triples,
individual
and/or
overall static screen

PVC- or PVCw- or PE- or XLPE(70C) (105C) (70C) (90C)


insulated/PVC-sheathed

PE- or XLPE(70C) (90C)


insulated/LSZH-sheathed

Mica/XLPE- or Silicone(90C) (90C)


insulated/LSZH-sheathed

unarmoured

armoured

unarmoured

armoured

unarmoured

armoured

Lead sheathed or
Multi layer sheathed, armoured

1)

gen. to EN 50288-7

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 B13

Instrumentation Cable

gen. to EN 50288-7

Fire resisting (CI), flame retardant Types

500 V

Single & Multi pair and Multi triple, individual and/or overall screen, LSZH-sheath
unarmoured,
armoured

Technical Data
Type of insulation/sheath

Mica tape + XLPE/LSZH

Type of cabling elements

Pair, Triple, PiMF, TiMF

No. of cabling elements

1, 2, 4, 5, 6, 8, 10, 12, 16, 20, 24

Conductor sizes

0.5 mm, 0.75 mm, 1.0 mm, 1.3 mm, 1.5 mm

1. Unarmoured types

Laying

Bending radius

RE-2X(St)H..CI

Laying

Bending radius

Temperature range
during operation
during installation

RE-2G(St)H..CI

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations
7.5 x cable

2. Armoured types

Silicone/LSZH

RE-2X(St)HSWAH 1)..CI

RE-2G(St)HSWAH 1)..CI

Recommended for outdoor installation, on racks,


trays, in conduits, in dry and wet locations, for direct burial
10 x cable

Resistance to fire
Circuit Integrity

- 30 C up to 90 C
- 5 C up to 50 C

- 30 C up to 90 C
- 5 C up to 50 C

a) IEC 60331-21, b) BS 6387 Cat. C, W, Z

Reaction to fire
Flame propagation
a) Test on single cable
b) Test on bunched cables
Test on gases evolved
during combustion
a) amount of halogen acid gases
b) degree of acidity of gases

IEC 60754-1 (0 %)
IEC 60754-2 (pH > 4.3, c < 10 S/mm)

Measurement of smoke density

IEC 61034-2 (L.T.2) > 60 %)

IEC 60332-1
IEC 60332-3 part 24 (Cat. C)

Oil resistance
Application

ICEA S-82-552
For transmission of analogue and digital signals in instrument and control systems,
where maintenance of circuit integrity in case of fire is required; allowed for use in
zone 1 and zone 2, group II, classified areas (IEC 60079-14); not allowed for direct
connection to low impedance sources, e.g. public mains electricity supply.

Alternative with outer sheath PVC; in this case tests Test on gases evolved during combustion
and Measurement of smoke density are not applicable
2)
L.T. = Light Transmission
1)

 B14

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Instrumentation Cable

gen. to EN 50288-7

Fire resisting (CI), flame retardant Types

500 V

Single & Multi pair and Multi triple, individual and/or overall screen, LSZH-sheath
unarmoured,
armoured

Construction
Product type

Unarmoured types

Conductor

Armoured types

Plain annealed copper; 7 stranded acc. to EN 60228, Class 2

cross-section
mm
conductor design mm

0.5
7 x 0.3

Insulation materials
Cabling element
without ind. screen
with ind. screen
1)

0.75
7 x 0.37

1.0
7 x 0.43

1.3
7 x 0.49

1.5
7 x 0.53

Mica tape + cross linked polyethylene XLPE or silicone


Pair, Triple
PiMF, TiMF

Individual screen

Aluminium/plastic-tape over tinned copper drain wire, 0.6 mm


plastic-tape under and above screen

Wrapping

at least one plastic tape above cable core

Overall screen

Aluminium/plastic tape over tinned copper drain wire 0.5 mm / 7 x 0.3 mm

Inner sheath

--

LSZH , black

Armouring

--

Galvanized steel wire; wire depending on


cable- under armouring, at least 0.9 mm

Outer sheath
Colour

LSZH1),
black or blue for intrinsically safe systems
ICON by KERPEN Instrumentation Cable gen. to EN 50288-7 Rated voltage
LSZH2) CE Length Marking

Marking

1)
2)

For armoured types also with outer sheath of PVC


The sign LSZH is not applicable, if an outer sheath of PVC is applied

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 B15

Instrumentation Cable

gen. to EN 50288-7

Fire resisting (CI), flame retardant Types

500 V

Single & Multi pair and Multi triple, individual and/or overall screen, LSZH-sheath
unarmoured,
armoured

Electrical Data at 20 C
Properties

Character

Unit

Conductor sizes

nom.

mm

0.5

Conductor resistance

max.

/km

36.7

Insulation resistance
Mica tape + XLPE-insulation
Silicone

min.
min.

Mxkm
Mxkm

L/R Ratio

max.

H/

Inductance

max.

mH/km

Mutual capacitance
Mica tape + XLPE-insulation
Pair, Triple 1), 2)

max.

nF/km

65

75

PiMF, TiMF

max.

nF/km

100

100

Silicone
Pair, Triple 1), 2)

max.

nF/km

110

110

PiMF, TiMF

max.

nF/km

150

150

Test voltage
Core/core
Core/core

(Urms)
(Urms)

Operating voltage

(Urms)

max.

Values
0.75

25.0

1.0

18.5

1.3

1.5

14.2

12.3

5000
300
25

40
1

V
V

2000
2000

500

Values for cables with 1 element correspond to those for PiMF and
TiMF resp.
2) Values for cables with 2 up to 4 elements + 20 %

1)

 B16

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Group 2:

Instrumentation Control Cable

acc. to EN 50288-7

Common Types

500 V

Instrumentation Control Cable

Common Types
500 V

plain stranded copper conductor,


cores,
overall static screen

PVC- or PVCw- or PE- or XLPE(70C) (105C) (70C) (90C)


insulated/PVC-sheathed

unarmoured

armoured

Halogen-free,
flame retardant types
500 V

plain stranded copper conductor


cores
overall static screen

PE- or XLPE-,
(70C) (90C)
insulated/LSZH-sheathed

unarmoured

armoured

Fire resisting (CI), 1)


flame retardant types
500 V

plain stranded copper conductor,


cores,
overall static screen

Mica/XLPE- or Silicone(90C) (90C)


insulated/LSZH-sheathed

unarmoured

armoured

Lead sheathed or
Multi layer sheathed, armoured

1)

gen. to EN 50288-7

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 C1

Instrumentation Control Cable

acc. to EN 50288-7

Common Types

500 V

Multi core, overall screen, PVC-sheath


unarmoured,
armoured
with chemical protection, armoured

Technical Data
Type of insulation/sheath

PVC/PVC

PVCw/PVCw

PE/PVC

Type of cabling elements

XLPE/PVC

Core

No. of cabling elements

2, 4, 5, 6, 8, 10, 12, 16, 20, 24, 36, 40

Conductor sizes

0.5 mm, 0.75 mm, 1.0 mm, 1.3 mm, 1.5 mm, 2.5 mm

1. Unarmoured types

RE-Yw(St)Yw-fl

RE-Y(St)Y-fl

Laying

RE-2Y(St)Y-fl 1)

RE-2X (St)Y-fl

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations

Bending radius

7.5 x cable

2. Armoured types
(Product code)
Laying

RE-Y(St)YSWAY-fl

RE-Yw(St)YwSWAYw-fl

RE-2Y(St)YSWAY-fl

RE-2X(St)YSWAY-fl

Recommended for outdoor installation, on racks,


trays, in conduits, in dry and wet locations, for direct burial

Bending radius

10 x cable

3. Armoured types with


chemical protection
a)
Lead sheathed

RE-Y(St)YMYSWAY-fl

--

--

RE-2X(St)YMYSWAY-fl

--

--

--

RE-2X(L)2Y4YSWAY 2) 3)

b)
Multi layer sheathed
Laying

Recommended for direct burial, especially in presence


of oil and aggressive chemical substances

Bending radius
Temperature range
during operation
during installation

15 x cable

- 30 C up to 70 C
- 5 C up to 50 C

Reaction to fire
Flame propagation
a) Test on single cable
b) Test on bunched cables

- 30 C up to 105 C
- 5 C up to 50 C

- 30 C up to 90 C
- 5 C up to 50 C

IEC 60332-1
IEC 60332-3 part 24 (Cat. C), (excluded types with multi layer-sheath)

Sunlight resistance

UL 1581 Section 1200

Oil resistance
Application

- 30 C up to 70 C
- 5 C up to 50 C

ICEA S-82-552
For control purposes, e.g. controlling of valves or engines; allowed for use in zone 1 and zone
2, group II, classified areas (IEC 60079-14); not allowed for direct connection to low impedance
sources, e.g. public mains electricity supply

Also with increased thickness of outer sheath


Also with HDPE outer sheath; in this case Test Reaction to Fire is not passed
3)
Max. operating temperature 80 C
1)
2)

 C2

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Instrumentation Control Cable

acc. to EN 50288-7

Common Types

500 V

Multi core, overall screen, PVC-sheath


unarmoured,
armoured
with chemical protection, armoured

Construction
Product type

Unarmoured types

Conductor

Plain annealed copper; 7 stranded acc. to EN 60228, Class 2

cross-section
mm
conductor design mm

0.5
7 x 0.3

0.75
7 x 0.37

Insulation materials

Cabling element 1)

Armoured types

1.0
7 x 0.43



1.3
7 x 0.49

1.5
7 x 0.53

2.5
7 x 0.67

Cross linked polyethylene XLPE or


Polyethylene PE or
Polyvinylchloride PVC or
Polyvinylchloride heat resistant PVCw
Core

Wrapping

at least one plastic tape above cable core

Overall screen

Aluminium/plastic tape over tinned copper drain wire 0.5 mm / 7 x 0.3 mm

Inner sheath

--

PVC and PVCw resp. , black

Armouring

--

Galvanized steel wire armouring; wire


depending on cable- under armouring, at
least 0.9 mm

Outer sheath 1)
Colour

PVC and PVCw resp. ,


black or blue for intrinsically safe systems
ICON by KERPEN Instrumentation Control Cable EN 50288-7
Rated voltage RP2) CE Length Marking

Marking

1)
2)

Colour code of cabling elements: see appendix II


RP = Reduced flame propagation; excluded types with multi-layer sheath

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 C3

Instrumentation Control Cable

acc. to EN 50288-7

Common Types

500 V

Multi core, overall screen, PVC-sheath


unarmoured,
armoured
with chemical protection, armoured

Construction
Product type

Lead sheathed, armoured types

Conductor

Plain annealed copper; 7 stranded acc. to EN 60228, class 2

cross-section
mm
conductor design mm

0.5
7 x 0.3

Insulation materials
Cabling element 1)

Multi layer sheathed, armoured types

0.75
7 x 0.37

1.0
7 x 0.43

1.3
7 x 0.49

1.5
7 x 0.53

PVC or XLPE

XLPE

Core

Wrapping

Plastic tape above cable core


Aluminium/plastic tape over tinned copper
drain wire 0.5 mm / 7 x 0.3 mm

see multi layer sheath

Inner sheath

PVC

--

Metal sheath

Lead sheath

--

PVC

--

Overall screen

Bedding

Longitudinal one side plastic coated aluminium


foil over tinned copper drain wire, 7 x 0.3 mm,
high density polyethylene sheath with an
additional polyamide covering. The aluminium
foil is bonding within the overlapping and with
the inner surface of the polyethylene sheath

Multi layer sheath

Armouring

Galvanized steel wire armouring; wire depending on cable- under armouring,


at least 0.9 mm

Outer sheath 1)
Colour

PVC
black or blue for intrinsically safe systems

1)
2)

 C4

PVC or PE (high density)


black or blue for intrinsically safe systems

ICON by KERPEN Instrumentation Control Cable EN 50288-7


Rated voltage RP2) CE Length Marking

Marking

2.5
7 x 0.67

Colour code of cabling elements: see appendix II


RP = Reduced flame propagation; excluded types with multi-layer sheath

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Instrumentation Control Cable

acc. to EN 50288-7

Common Types

500 V

Multi core, overall screen, PVC-sheath


unarmoured,
armoured
with chemical protection, armoured

Electrical Data at 20 C
Properties

Character

Unit

Conductor sizes

nom.

mm

0.5

Conductor resistance

max.

/km

36.0

Insulation resistance
PVC / PVCw -insulation

min.

Mxkm

100

PE / XLPE -insulation

min.

Mxkm

5000

L/R Ratio

max.

H/

Inductance

max.

mH/km

Mutual capacitance
PVC / PVCw-insulation

max.

nF/km

170

PE / XLPE-insulation

max.

nF/km

115

V
V

2000
2000

500

Test voltage
Core/core
Core/screen

(Urms)
(Urms)

Operating voltage

(Urms)

max.

Values
0.75
24.5

1.0

1.3

18.1

13.9

25

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

40

1.5

2.5

12.1

7.41

60

 C5

 C6

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Group 2:

Instrumentation Control Cable

acc. to EN 50288-7

Halogen-free, flame retardant types

500 V

Instrumentation Control Cable

Common Types
500 V

plain stranded copper conductor,


cores,
overall static screen

PVC- or PVCw- or PE- or XLPE(70C) (105C) (70C) (90C)


insulated/PVC-sheathed

unarmoured

armoured

Halogen-free,
flame retardant types
500 V

plain stranded copper conductor


cores
overall static screen

PE- or XLPE-,
(70C) (90C)
insulated/LSZH-sheathed

unarmoured

armoured

Fire resisting (CI), 1)


flame retardant types
500 V

plain stranded copper conductor,


cores,
overall static screen

Mica/XLPE- or Silicone(90C) (90C)


insulated/LSZH-sheathed

unarmoured

armoured

Lead sheathed or
Multi layer sheathed, armoured

1)

gen. to EN 50288-7

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 C7

Instrumentation Control Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

500 V

Multi core, overall screen, LSZH-sheath


unarmoured
armoured

Technical Data
Type of insulation/sheath

PE/LSZH

XLPE/LSZH

Types of cabling elements

Core

No. of cabling elements

2, 4, 5, 6, 8, 10, 12, 16, 20, 24, 36,40

Conductor sizes

0.5 mm, 0.75 mm, 1.0 mm, 1.3 mm, 1.5 mm, 2.5 mm

1. Unarmoured types

RE-2Y(St)H

Laying

RE-2X(St)H

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations

Bending radius

7.5 x cable

2. Armoured types

RE-2Y(St)HSWAH

Laying

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations, for direct burial

Bending radius
Temperature range
during operation
during installation

10 x cable

- 30 C up to 70 C
- 5 C up to 50 C

Reaction to fire
Flame propagation
a) Test on single cable
b) Test on bunched cables

IEC 61034-2 (L.T.1) > 60 %)

Oil resistance

ICEA S-82-552
For control purposes, e.g. controlling of valves or engines; allowed for use in zone 1 and
zone 2, group II, classified areas (IEC 60079-14); not allowed for direct connection to low
impedance sources, e.g. public mains electricity supply. Recommended for use as fire
protection measure for people and for important material assets

1)

 C8

- 30 C up to 90 C
- 5 C up to 50 C

IEC 60754-1 (0 %)
IEC 60754-2 (pH > 4.3, c < 10S/mm)

Measurement of smoke density

IEC 60332-1
IEC 60332-3 part 24 (Cat. C)

Test on gases evolved


during combustion:
a) amount of halogen acid gas
b) degree of acidity of gases

Application

RE-2X(St)HSWAH

L.T. = Light Transmission


KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Instrumentation Control Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

500 V

Multi core, overall screen, LSZH-sheath


unarmoured
armoured

Construction
Product type

Unarmoured types

Conductor
cross-section

Armoured types

Plain annealed copper; 7 stranded acc. to EN 60228, class 2


mm

0.5
7 x 0.3

conductor design mm

0.75
7 x 0.37

1.0
7 x 0.43

1.3
7 x 0.49

1.5
7 x 0.53

2.5
7 x 0.67

Polyethylene PE or
Cross linked polyethylene XLPE

Insulation materials

Cabling element

core

Wrapping

at least one plastic tape above cable core

Overall screen

Aluminium/plastic tape over tinned copper drain wire 0.5 mm / 7 x 0.3 mm

Inner sheath

--

LSZH , black

Armouring

--

Galvanized steel wire; wire depending on


cable- under armouring, at least 0.9 mm

Outer sheath
Colour 1)

LSZH,
black or blue for intrinsically safe systems
ICON by KERPEN Instrumentation Control Cable EN 50288-7
Rated voltage LSZH CE Length Marking

Marking

1)

Colour code of cabling elements: see appendix II

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 C9

Instrumentation Control Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

500 V

Multi core, overall screen, LSZH-sheath


unarmoured
armoured

Electrical Data at 20 C
Properties

Character

Unit

Conductor sizes

nom.

mm

0.5

Conductor resistance

max.

/km

36.0

Insulation resistance
PE / XLPE -insulation

min.

Mxkm

L/R Ratio

max.

H/

Inductance

max.

mH/km

Mutual capacitance

max.

nF/km

115

V
V

2000
2000

500

Test voltage
Core/core
Core/screen

(Urms)
(Urms)

Operating voltage

(Urms)

 C10

max.

Values
0.75

24.5

1.0

1.3

18.1

13.9

1.5

2.5

12.1

7.41

5000
25

KERPEN GmbH & Co. KG

40

60

09.2006 Printing errors excepted. Subject to alterations

Group 2:

Instrumentation Control Cable

acc. to EN 50288-7

Fire resisting (CI), flame retardant types

500 V

Instrumentation Control Cable

Common Types
500 V

plain stranded copper conductor,


cores,
overall static screen

PVC- or PVCw- or PE- or XLPE(70C) (105C) (70C) (90C)


insulated/PVC-sheathed

unarmoured

armoured

Halogen-free,
flame retardant types
500 V

plain stranded copper conductor


cores
overall static screen

PE- or XLPE-,
(70C) (90C)
insulated/LSZH-sheathed

unarmoured

armoured

Fire resisting (CI), 1)


flame retardant types
500 V

plain stranded copper conductor,


cores,
overall static screen

Mica/XLPE- or Silicone(90C) (90C)


insulated/LSZH-sheathed

unarmoured

armoured

Lead sheathed or
Multi layer sheathed, armoured

1)

gen. to EN 50288-7

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 C11

Instrumentation Control Cable

gen. to EN 50288-7

Fire resisting (CI), flame retardant Types

500 V

Multi core, overall screen, LSZH-sheath


unarmoured
armoured

Technical Data
Type of insulation/sheath

Mica tape + XLPE/LSZH

Type of cabling elements

Core

No. of cabling elements

2, 4, 5, 6, 8, 10, 12, 16, 20, 24, 36, 40

Conductor sizes

0.5 mm, 0.75 mm, 1.0 mm, 1.3 mm, 1.5 mm , 2.5 mm

1. Unarmoured types

RE-2X(St)H..CI

Laying

RE-2G(St)H..CI

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations

Bending radius

7.5 x cable

2. Armoured types

RE-2X(St)HSWAH 1)..CI

Laying

10 x cable

Resistance to fire
Circuit Integrity

- 30 C up to 70 C
- 5 C up to 50 C

- 30 C up to 90 C
- 5 C up to 50 C

a) IEC 60331-21, b) BS 6387 Cat. C, W, Z

Reaction to fire
Flame propagation
a) Test on single cable
b) Test on bunched cables
Test on gases evolved
during combustion
a) amount of halogen acid gases
b) degree of acidity of gases
Measurement of
smoke density

IEC 60332-1
IEC 60332-3 part 24 (Cat. C)
IEC 60754-1 (0 %)
IEC 60754-2 (pH > 4.3, c < 10 S/mm)
IEC 61034-2 (L.T.2) > 60 %)

Oil resistance
Application

RE-2G(St)HSWAH 1)..CI

Recommended for outdoor installation, on racks,


trays, in conduits, in dry and wet locations, for direct burial

Bending radius
Temperature range
during operation
during installation

Silicone/LSZH

ICEA S-82-552
For control purposes, e.g. controlling of valves or engines where maintenance of circuit
integrity in case of fire is required; allowed for use in zone 1 and zone 2, group II,
classified areas (IEC 60079-14); not allowed for direct connection to low impedance
sources, e.g. public mains electricity supply

Alternative with outer sheath PVC; in this case tests Test on gases evolved during combustion
and Measurement of smoke density are not applicable
2)
L.T. = Light Transmission
1)

 C12

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Instrumentation Control Cable

gen. to EN 50288-7

Fire resisting (CI), flame retardant Types

500 V

Multi core, overall screen, LSZH-sheath


unarmoured
armoured

Construction
Product type

Unarmoured types

Conductor

Armoured types

Plain annealed copper; 7 stranded acc. to EN 60228, class 2

cross-section
mm
conductor design mm

0.5
7 x 0.3

Insulation materials

0.75
7 x 0.37

1.0
7 x 0.43

1.3
7 x 0.49

1.5
7 x 0.53

2.5
7 x 0.67

Mica tape + Cross linked polyethylene XLPE or silicone

Cabling element 1)

Core

Wrapping

at least one plastic tape above cable core

Overall screen

Aluminium/plastic tape over tinned copper drain wire 0.5 mm / 7 x 0.3 mm

Inner sheath

--

LSZH, black

Armouring

--

Galvanized steel wire armouring; wire


depending on cable- under armouring, at
least 0.9 mm

Outer sheath 1)
Colour

LSZH,
blue for intrinsically safe systems
ICON by KERPEN Instrumentation Control Cable EN 50288-7
Rated voltage LSZH CI CE Length Marking

Marking

1)

The sign LSZH is not applicable, if a outer sheath of PVC is applied.

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 C13

Instrumentation Control Cable

gen. to EN 50288-7

Fire resisting (CI), flame retardant Types

500 V

Multi core, overall screen, LSZH-sheath


unarmoured
armoured

Electrical Data at 20 C
Properties

Character

Unit

Conductor sizes

nom.

mm

0.5

Conductor resistance

max.

/km

36.7

Insulation resistance
Mica tape + XLPE-insulation

min.

M x km

5000

Silicone

min.

M x km

150

L/R Ratio

max.

H/

Inductance

max.

mH/km

Mutual capacitance
Mica tape + XLPE-insulation

max.

nF/km

100

Silicone

max.

nF/km

150

V
V

2000
2000

500

Test voltage
Core/core
Core/screen

(Urms)
(Urms)

Operating voltage

(Urms)

 C14

max.

Values
0.75
25.0

1.0

1.3

18.5

14.2

25

KERPEN GmbH & Co. KG

40

1.5

2.5

12.3

7.41

60

09.2006 Printing errors excepted. Subject to alterations

Group 3:

Extension and Compensating Cable

acc. to EN 50288-7

Common types

300 V

Extension and Compensating Cable

Common Types
300 V

Halogen-free,
flame retardant types
300 V

solid conductors,
pairs,
individual
and/or
overall static screen

solid conductors,
pairs,
individual
and/or
overall static screen

PVC- or PVCw- or PE- or XLPE(70C) (105C) (70C) (90C)


insulated/PVC-sheathed

PE- or XLPE(70C) (90C)


insulated/LSZH-sheathed

unarmoured

armoured

unarmoured

Fire resisting (CI), 1)


flame retardant types
500 V 2)

armoured

Lead sheathed or
Multi layer sheathed, armoured

1)
2)

gen. to EN 50288-7
on request

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 D1

Extension and Compensating Cable

acc. to EN 50288-7

Common Types

300 V

Single & Multi pair, individual and/or overall screen, PVC-sheath


unarmoured,
armoured
with chemical protection, armoured

Technical Data
Type of insulation/sheath

PVC/PVC

PVCw/PVCw

Type of cabling elements

PE/PVC

XLPE/PVC

Pair, PiMF

No. of cabling elements

1, 2, 4, 5, 6, 8, 10, 12, 16, 20, 24

Conductor material

Extension or compensating material acc. to IEC 60584-3 / see appendix I

Conductor sizes

0.8 mm, 1.02 mm, 1.13 mm, 1.29 mm, 1.38 mm

1. Unarmoured types

RT-Y(St)Y-fl

Laying

RT-Yw(St)Yw-fl

RT-2Y(St)Y-fl

RT-2X (St)Y-fl

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations

Bending radius

7.5 x cable

2. Armoured types

RT-Y(St)YSWAY-fl

Laying

RT-Yw(St)YwSWAYw-fl

RT-2Y(St)YSWAY-fl

RT-2X(St)YSWAY-fl

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations, for direct burial

Bending radius

10 x cable

3. Armoured types with


chemical protection
a) Lead sheathed

RT-Y(St)YMYSWAY-fl

--

--

RT-2X(St)YMYSWAY-fl

--

--

--

RT-2X(L)2Y4YSWAY1) 2)

b) Multi layer sheathed


Laying

Recommended for direct burial, especially in presence


of oil and aggressive chemical substances

Bending radius
Temperature range
during operation
during installation

15 x cable

- 30 C up to 70 C
- 5 C up to 50 C

Reaction to fire
Flame propagation
a) Test on single cable
b) Test on bunched cables

- 30 C up to 105 C
- 5 C up to 50 C

UL 1581 Section 1200

Oil resistance

ICEA S-82-552
For transmission of thermoelectric voltage from measuring junction to reference junction;
allowed for use in zone 1 and zone 2, group II (IEC 60079-14)

1)
2)

 D2

- 30 C up to 90 C
- 5 C up to 50 C

IEC 60332-1
IEC 60332-3 part 24 (Cat. C), (excluded types with multi layer-sheath)

Sunlight resistance

Application

- 30 C up to 70 C
- 5 C up to 50 C

Also with HDPE outer sheath; in this case Tests Reaction to Fire are not passed
max. operating temperature 80 C

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Extension and Compensating Cable

acc. to EN 50288-7

Common Types

300 V

Single & Multi pair, individual and/or overall screen, PVC-sheath


unarmoured,
armoured
with chemical protection, armoured

Construction
Product type

Unarmoured types

Conductor

Extension or compensating material acc. to IEC 60584-3

cross-section
mm
conductor design mm

0.5
1 x 0.8

0.75
1 x 1.02

Insulation materials

Cabling element 1)
without ind. screen
with ind. screen

Armoured types

1.0
1 x 1.13

1.3
1 x 1.29

1.5
1 x 1.38

Cross linked polyethylene XLPE or


Polyethylene PE or
Polyvinylchloride PVC or
Polyvinylchloride heat resistant PVCw

Pair
PiMF

Aluminium/plastic-tape over solid tinned copper drain wire, 0.6 mm


plastic-tape under and above screen

Individual screen
Wrapping

at least one plastic tape above cable core

Overall screen

Aluminium/plastic tape over tinned copper drain wire 0.5 mm / 7 x 0.3 mm

Inner sheath

--

PVC and PVCw resp. , black

Armouring

--

Galvanized steel wire armouring;


wire depending on cable- under
armouring, at least 0.9 mm

Outer sheath
Colour

PVC and PVCw resp. ,


see appendix I, Table 1 or blue for intrinsically safe systems
ICON by KERPEN Extension or Compensating Cable EN 50288-7
Rated voltage RP2) CE Length Marking

Marking

1)
2)

Colour code of cabling elements: see appendix I, Table 1


RP = Reduced flame propagation

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 D3

Extension and Compensating Cable

acc. to EN 50288-7

Common Types

300 V

Single & Multi pair, individual and/or overall screen, PVC-sheath


unarmoured,
armoured
with chemical protection, armoured

Construction
Product types

Lead sheathed, armoured types

Multi layer sheathed, armoured types

Extension and compensating material acc. to IEC 60584-3

Conductor
cross-section
mm
conductor design mm

0.5
1 x 0.8

Insulation materials

0.75
1 x 1.02

1.0
1 x 1.13

1.3
1 x 1.29
XLPE

PVC or XLPE

Cabling element 1)
without ind. screen

Pair

with ind. screen

PiMF

Individual screen

Aluminium/plastic-tape over tinned copper drain wire, 0.6 mm,


plastic-tape under and above screen

Wrapping

Plastic tape above cable core

Overall screen

Inner sheath

Metal sheath
Bedding

Multi layer-sheath

Aluminium/plastic tape over tinned copper


drain wire 0.5 mm / 7 x 0.3 mm

see multi layer sheath

PVC

--

Lead sheath

--

PVC

--

--

Longitudinal one side plastic coated


aluminium foil over tinned copper drain wire,
7 x 0,3 mm, high density polyethylene sheath
with an additional polyamide covering.
The aluminium foil is bonding within the
overlapping and with the inner surface of the
polyethylene sheath

Armouring

Galvanized steel wire; wire depending on cable- under armouring,


at least 0.9 mm

Outer sheath
Colour

PVC
see appendix I, Table 1

Marking

2)

 D4

PVC or PE (high density)


see appendix I, Table 1

ICON by KERPEN Extension or Compensating Cable


EN 50288-7 Rated Voltage RP2) CE Length Marking

1)

1.5
1 x 1.38

Colour code of cabling elements: see appendix I, Table 1


RP = Reduced flame propagation, excluded types with multi layer sheath

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Extension and Compensating Cable

acc. to EN 50288-7

Common Types

300 V

Single & Multi pair, individual and/or overall screen, PVC-sheath


unarmoured,
armoured
with chemical protection, armoured

Electrical Data at 20 C
Properties

Character

Unit

Conductor sizes

nom.

mm

Conductor resistance (Loop)

max.

/km

see appendix I, table 2

Insulation resistance
PVC / PVCw -insulation

min.

Mxkm

100

PE / XLPE -insulation

min.

Mxkm

5000

approx.

mH/km

see appendix I, table 2

max.

nF/km

150

160

max.

nF/km

190

200

max.

nF/km

75

85

max.

nF/km

115

115

Inductance
Mutual capacitance
PVC / PVCw-insulation
Pair1), 2)

PiMF

PE / XLPE-insulation
Pair 1), 2)

PiMF

Test voltage
Core/core
Core/screen

(Urms)
(Urms)

Operating voltage

(Urms)

max.

Values
0.5

0.75

1.0

V
V

1500
1500

300

1)
2)

1.3

1.5

Values for cables with 1 element correspond to those for PiMF


Values for cables with 2 up to 4 elements + 20 %

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 D5

 D6

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Group 3:

Extension and Compensating Cable

acc. to EN 50288-7

Halogen-free, flame retardant types

300 V

Extension and Compensating Cable

Common Types
300 V

Halogen-free,
flame retardant types
300 V

solid conductors,
pairs,
individual
and/or
overall static screen

solid conductors,
pairs,
individual
and/or
overall static screen

PVC- or PVCw- or PE- or XLPE(70C) (105C) (70C) (90C)


insulated/PVC-sheathed

PE- or XLPE(70C) (90C)


insulated/LSZH-sheathed

unarmoured

armoured

unarmoured

Fire resisting (CI), 1)


flame retardant types
500 V 2)

armoured

Lead sheathed or
Multi layer sheathed, armoured

1)
2)

gen. to EN 50288-7
on request

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 D7

Extension and Compensating Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

300 V

Single & Multi pair, individual and/or overall screen, PVC-sheath


unarmoured,
armoured

Technical Data
Type of insulation/sheath

XLPE/LSZH

PE/LSZH

Types of cabling elements

Pair, PiMF

No. of cabling elements

1, 2, 4, 5, 6, 8, 10, 12, 16, 20, 24

Conductor material

Extension or compensating material acc. to IEC 60584-3 /see appendix I, Table 2

Conductor sizes

0.5 mm, 0.75 mm, 1.0 mm, 1.3 mm, 1.5 mm

1. Unarmoured types

Laying

Bending radius

RT-2Y(St)H

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations
7.5 x cable

2. Armoured types

Laying

Bending radius

Temperature range
during operation
during installation

RT-2Y(St)HSWAH

10 x cable

- 30 C up to 70 C
- 5 C up to 50 C

IEC 61034-2 (L.T.1) > 60 %)


ICEA S-82-552
For transmission of thermoelectric voltage from measuring junction to reference junction;
allowed for use in zone 1 and zone 2, groupII, classified areas (IEC 79-14)

1)

 D8

- 30 C up to 90 C
- 5 C up to 50 C

IEC 60754-1 (0 %)
IEC 60754-2 (pH > 4.3, c < 10S/mm)

Oil resistance

IEC 60332-1
IEC 60332-3 part 24 (Cat. C)

Measurement of smoke density

Application

RT-2X(St)HSWAH

Recommended for indoor and outdoor installation, on racks,


trays, in conduits, in dry and wet locations, for direct burial

Reaction to fire
Flame propagation
a) Test on single cable
b) Test on bunched cables
Test on gases evolved during
combustion:
a) amount of halogen acid gas
b) degree of acidity of gases

RE-2X(St)H

L.T. = Light transmission

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Extension and Compensating Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

300 V

Single & Multi pair, individual and/or overall screen, PVC-sheath


unarmoured,
armoured

Construction
Product type

Unarmoured types

Conductor

Extension or compensating material acc. to IEC 60584-3

cross-section
mm
conductor design mm

0.5
1 x 0.8

0.75
1 x 1.02

Insulation materials
Cabling element 1)
without ind. screen
with ind. screen

Armoured types

1.0
1 x 1.13

1.3
1 x 1.29

1.5
1 x 1.38

Polyethylene PE or
Cross linked Polyethylene XLPE

Pair
PiMF

Individual screen

Aluminium/plastic-tape over tinned copper drain wire, 0.6 mm


plastic-tape under and above screen

Wrapping

at least one plastic tape above cable core

Overall screen

Aluminium/plastic tape over tinned copper drain wire 0.5 mm / 7 x 0.3 mm

Inner sheath

--

LSZH, black

Armouring

--

Galvanized steel wire; wire depending on


cable- under armouring, at least 0.9 mm

Outer sheath
Colour

LSZH,
see appendix I, Table 1 or blue for intrinsically safe systems
ICON by KERPEN Extension or Compensating Cable
EN 50288-7 Rated voltage LSZH CE Length Marking

Marking

1)

Colour code of cabling elements: see appendix I

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 D9

Extension and Compensating Cable

acc. to EN 50288-7

Halogen-free, flame retardant Types

300 V

Single & Multi pair, individual and/or overall screen, PVC-sheath


unarmoured,
armoured

Electrical Data at 20 C
Properties

Character

Unit

Conductor sizes

nom.

mm

Conductor resistance (Loop)

max.

/km

see appendix I, Table 2

Insulation resistance
PE / XLPE -insulation

min.

Mxkm

5000

approx.

mH/km

see appendix I, Table 2

max.

nF/km

75

85

max.

nF/km

115

115

Inductance
Mutual capacitance
PE / XLPE-insulation
Pair 1), 2)

PiMF

Test voltage
Core/core
Core/screen

(Urms)
(Urms)

Operating voltage

(Urms)

max.

Values
0.5

 D10

1.0

V
V

1500
1500

300

1)

0.75

2)

1.3

1.5

Values for cables with 1 element correspond to those for PiMF


Values
for cables with 2 up to 4 elements + 20 %

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Appendix

ouple
thermoc

g
ensatin

n & comp

extensio

cables

tors
conduc
nces of
eaths
d tolera
ges an
outer sh
ture ran ulations and
Tempera
of ins
1) 2)
s
de
84
co
IEC 605
Colour

rds for
Standa
Table 1

ASTM

E 230

1)

l
l
r-Nicke
r-Nicke
-)
/Coppe
/Coppe
Copper ---------------Copper 57V/ 5 C)
(
2.5C)
1:-----(Class 2: 30 V/
+200 C
l SX
Cu
(Class
Fla
r-Nicke 0 C up to
/Coppe
---)
me
CuNi
Copper ---------------Mu
Re
ss 1:-- 60 V/ 5 C)
(Cla
lt
CB
2:
tar
opper)
RCB/S to + 200 C
Cu
(Class
pper/C
RE i-Pair
da
per (Co V/ + 0 C)
0 C up
-Y
CuNi
nt,
(+ 0.0 V/-3.7 C)
-alloy/Cop
(S , PVC
Copper 0 C
Ap
t)Y
(-33
Su
BX
Ins
+10
r
p
MY
y (Cu)
nli
/Coppe
C up to
Fo lica
Cu-allo (Cu)
SW ulati
Copper 3.5 C) 0
ti
r
gh
IUM
Cu
o
tr
II c an
on
n
AY
% RHOD
tR
( 40 V/
, In
UM-13
-
su lass smis
l
es
icke
C
p
i
+ PLATIN UM
r-N
PiM divid
BC
Cu
ppe
ist
Re ply. ed sion
to + 100
Iron/Co l: 1.1 C)
- PLATIN
are of
0 C up
co
ua
F
Cu
an
m
(specia 2.2 C)
Co
l&
as an
t
rd:
C
ns men
(IE alo
IUM
Co
(standa
l JX up to + 200
gu
tr
C
RHOD IUM
d
Fe
C
icke
%
lle
e
u
o
r-N
d
0 C
60 e a
nd
ppe
cti
UM-30
cti
RHOD
CuN
07
Iron/CoV/ 1.5 C)
uc
nd
on for d
ve
+ PLATIN UM- 6 %
9
to
85
C)
TIN
d

ir
-1
2.5
Sc
1:
r ....
Ins
ec
- PLA
4); igita
(Class 140 V/
ree
ickel
tb
ula
....
no l sig
pper-N C)
u
JX
Fe
+ 200 C (Class 2:
C
..
/Co
ti
n,
to
ri
t
o
..
up
per
al,
lou on ..
....
all na
Cop
l: 0.5
Le
- 25 C
CuNi
ow ls
es
....
(specia 1.0 C)
rc
....
ad
in
p
..
rd:
e
o
..
e
C
nda
d
de
..
Sh
Ind
cia
(sta
pla
for instr
to + 100
l TX
.... ........
ea
lly
ivid
in
r-Nicke 0 C up
dir um
....
th,
Cu
in
ua
/Coppe
ec
e
.... ..... 1.0m ann
pre
+ IRON ER-NICKEL
Copper V/ 0.5 C)
Arm
ls
t c nt a
Wra
....
CuNi
C)
30
hie
se
on
nd
... poly m, 1 ealed
- COPP
ss 1: 60 V/ 1.0
ou
n
p
ld
n
(Cla
ce
Co
p
ec con
C
.3
....
bla viny
r, P
2:
TX
of
lle ing ..
tio
to + 100
l ch mm copp
....
(Class
tro
ck
VC
ickel
c
n
o
Cu
m
..
..
r-N
ti
e
l
25 C up
il
,
lo
/
..
ppe
...
to
ve
ult
s
r,
w
an
ri
1
Sh
ium/Co ( 1.7 C)
low yste
Inn
CuNi
sc ........
da
24 ipair hite de P .5m stra
Chrom
ea
ree
m
e
,
70
..
n
s
Nickelg
im
m
V

r
c
s
de
th
gre
Me
C
wir m
s
on

n .. ......
pe ; all
C
C
d,
EX
tinu
alu
ss
e,
tal heath
.
....
da
ow
NiCr
ickel 0 C up to + 200
s
B
iv
/
a
m
r-N
..
0
iz
n
s
o
ER
e
t
e
e
ppe
...
h
.6
ce
us
es
in
..
le
d
d
Ni
ch
+ COPP ER-NICKEL
ium/Co 1.5 C)
ly
: 0
so for
Arm ding eath ......
24 ast 1 mm ium
em
V/
Chrom
nu
u
..
.5
..
- COPP
u
Nickel- ss 1: 120 V/ 2.5C)
/

..
rc
..

ic
..
m
s
m
lay
....
m
, p PE
d
e
ium
Ou our .. ...... ....
e,
al
be
m,
C (Cla ss 2: 200
Alumin
su
e.g in z
red
ter
.... ...... .. p rain w alum er o lasti TP
EX
....
NiCr
(Cla
to + 200
/Nickel- ( 2.2 C)
b
o
C
up
f
0
ium
..
.
c
..
ta
..
C
s
s
o
p
ir
.75
on
ab
..
in
the ne
tan
- 25
Chrom
CuNi
le heath ........ ...... .. le lyvin e, 0.5 ium lastic tape pe o
m
Nickel- C
wh
ce
pu 1 an
yl c
ma
...
ad
..
m
u
v
s
it
/
..
KX
m
200
ta
e
..
b
n
.
+
e
d
,
PE
de r s
lic
rkin ...... ....
hlo
p
po
co
minium 0 C up to
r a olid
TP e
ma zone
rid m
lyv
OMIUM
re
kel-Alu
g .. ...... ...
nd
NiCr
eP
L-CHR
in
ins
ium/Nic60 V/ 1.5 C)
g
(1,
tap
2
....
Te
ab tinn
Chrom
C)
Ni
+ NICKEER-NICKEL
VC
.... .... p alvan yl ch
eo
2..
ele grou
ch
ov ed
Nickel- (Class 1:
V/ 2.5
,b
....
) fo
- COPP
ize lori
es
ctr
nic
ve
oly
l
Fla
lac
.
200 C (Class 2: 100
l
r7
KX
icit p
r
cre copp
al
r-Nicke
ICO viny d rou de P
up to +
k
me
r-Nicke
-str
y
/Coppe 2.2 C)
en er
- 25 C
/Coppe
Te
---)
pro data
Copper
(
an
dra
E N b l chlo nd s VC, b
Copper ---------------s
de
pa
N 5 y K rid
in
te
la
Te t on
1:-----d ti
2.5 C)
st
sin gati
02 ER e P el w ck
(Class 2: 100V/
VX
n
l
C
B
o
1.1
V
88
ir
ne
on
icke ISA RP
KC
n b gle
(Class
to + 100
100 C
-7 PEN C, b es
pper-N
dc
:
Cu
ca
un
0 C up
Iron/Co --------------) 0 C up to +
C
la

o
b
c
IN
p
c
i
---E
le
he
pe
k
CuN
2.5 C)
1:-----dc :
r
Le STR ; blu
(Class 2: 100V/
ab
e fo
U
n
A
C
A
KC
g
KC
ss
IUM
M
150
les
IEC
th
(Cla
OM
Su
to +
KCB
L-CHR
M
Fe
:
ma ENT r intr
0C up
n
KX
+ NICKEL-ALUMINIU
IEC 603
Oil light
Cu
rkin ATIO insic
CuNi
NiCr
res
re
- NICKE
60 32-1
g
N C ally
CuNi
ista sista
33
Ni
AB safe
icone
2-3 -2
nc
nc
ium-Sil
LE
e
s
e:
-24
e:
Chrom
Silicon
3 yste
NickelNickel- 1.5 C)
(C
Ele
00
m

at.
ctr
V s
60 V/ 2.5 C)
UL
C)
NX
ic
T
ss 1:

RP
e
(Cla
V/
al
m
IC 1581
da
200 C
2: 100
l
EA
Co
(Class
- 3 pera
up to +
ta
s
r-Nicke
e
ppe
n
tu
- 25 C
0
S-8
at
c
/Co
re
(du C
Co ducto
20
Copper ------------------)
2-5 tion
ran
up
n
1
ri
---C
C)
r
5
d
1:-2
n
2.5
g
siz

-5
ss
2
to
uc
00
g
e
Ins
e
C (Class 2: 100V/
C ope + 7 :
ula tor res not
NC
(d
ONE NC up to + 150
A
0
ra
(Cla
u
ILIC
doe
ti
M
b
u
sis ing
0C
NX
rin p to tion C
bre
Cu
u of ANoSI
MIUM-S
n
satta
g in
RE
-CHRO
)
systemtual comrepen
+
via
nc
CuCrSi
sis
cation Indion and
CuNi
ca
+ NICKELL-SILICONE
sta 50
Min
ti
identi
ens u
2Y
pda X. tanc e
C
lla
NiSi
Ins ons
84. The r between extL/R arectama
- NICKE
tio
e ce
15 . be n
ncrke cita toleran
tr
IEC 605
als (r
(S
n)
diffe
xc
ces to
d
ins ume
t)
all materi
areti ranege and nce-user
Te atu
toleran
ab ing ra
u
n
cables;
o)
Y
s
n end
Ch
ges and
per
le-
co latio tatio
s to
diu
the tem t vupo
ara
olt n betwee
ature ran
ll
n
M
er sheath
For BX
s:
ag
Temper
ou ectiv of P n Ca
cte
1989.
and out
be agreedr.
e
July
to
n
te
.f.
ble
tors
e
e
3,
r
t
Y
om
c
duc
hav
par
she r sh scre E
basic e.m ple
for con
nufacture ore
rds the
cou
coding 3, July 1989
ma .
ath eath en
:c
S
and maO
rmocou
nda
rmo
our
c
the
sta
W
b
the
Col
t
p
ore
the
ore
x
e
era
84. par
1) In all of the same
Un
letter of
by X
Y A s ddin of lea of P
:s
min .
tin
IEC 605
cation
ntied
it
values
al
te
dnti
ide
VC
d
c
g
g
ide
ntic
pon
are
re
e
ide
-
les
mm
s the
vo
corres
en
ma .
ou l wir of PV
type are
Beside extension cab C
lta
rds are
U

ea
ter
x.
ording
ge
C
P
e,
by
Standa ndard 60584

acc
typ
les
(rm
ing
is
iM
ple
/k
ma
cab
low
NC
-Sta
F with re shea rmou
U s)
sating
2) Fol
M m
NX and
x
the IEC
r
pa
compen
th
(rm
of BC,
Da
ing with
ma .
xk
ir in duce
of
0.5
ur coding
U s)
22
x.
m
Up te of
nF
The colo 22.
(rm
me d a PVC
DIN 437
da
/k
+ 30
36
s)

437
m
tal
te: issue
.7
mH m
7 part 20
to DIN
File
KE
:
xx
foil e pro
0.7
BS 493
Va
: 7E
/k
.xx xx.x
RP
pa
5
lue
01
.xx x.x
32-424
H m
EN
ga
03
25
s
1
xx
xx
00
NFC
19
tion
/
.0
Gm
00
x
0 section
0
1
_R
161
.0
C
E_Y
bH
JIS

Type

LE

COUP
THERMO
L
MATERIA

%
UM-13
+ PLATIN UM
- PLATIN

S
B

IUM

RHOD

CA
RCA/S to + 100 C
0 C up

Ins

tru
m

en
tat

ion

Ca

ble

EN

50
28
8
30

-7

0V

+N

(S

&

t)Y

MY
S

WAY

_P

IM
F_

V
Tra Co.
25
KG
ns
V
fer
to

thir
V
d
Ph
Pri part
on
EV
nti
_0
e:
ng ies o
0.do
+
n
err
49
c
ors ly by
2
ex auth 4 02
ce
17
pte ority
30
d.
Su of K
7
bje ER

P
ct
to EN
In
alt
era Gmb tern
et:
tio H &
n
ww
Co
.K
w.k
G
e

19

18
.5
10
0
19
0

25

RM
_R

25
15

30

rp

en

15
00

14
20

1.3

.2
12

0
20

40

00

1.5
.3

40

.co

Cre

ato

r: P

M-I
/D

Pa
ge
1

/3

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 E1

Appendix
Appendix I: Standards for thermocouple extension & compensating cables

Standards for thermocouple extension & compensating cables


Table 1
Temperature ranges and tolerances of conductors
Table 1 Temperature ranges and tolerances of conductors

Colour codes of insulations and outer sheaths
Colour codes of insulations and outer sheaths

Type

IEC 60584 1)

THERMOCOUPLE
MATERIAL

+ PLATINUM-13 % RHODIUM
- PLATINUM

ASTM E 230 1)

2)

RCA/SCA
0 C up to + 100 C
RCB/SCB
0 C up to + 200 C

Copper/Copper-Nickel
(Class 1:-----------------------)
(Class 2: 30 V/ 2.5C)
Copper/Copper-Nickel SX
(Class 1:---------------------) 0 C up to +200 C
(Class 2: 60 V/ 5 C)

+ PLATINUM-13 % RHODIUM
- PLATINUM

S
B

+ PLATINUM-30 % RHODIUM
- PLATINUM- 6 % RHODIUM

+ IRON
- COPPER-NICKEL

+ COPPER
- COPPER-NICKEL

+ NICKEL-CHROMIUM
- COPPER-NICKEL

Cu
CuNi
BC
0 C up to + 100 C

Cu
CuNi

Copper/Copper BX
Copper-alloy/Copper (Copper/Copper)
( 40 V/ 3.5 C) 0 C up to +100 C
(+ 0.0 V/ + 0 C)
(-33 V/-3.7 C)
Cu
Cu

JX
- 25 C up to + 200 C

Copper/Copper-Nickel
( 57V/ 5 C)

Cu-alloy (Cu)
Cu (Cu)

Iron/Copper-Nickel JX
(Class 1: 85 V/ 1.5 C) 0 C up to + 200 C
(Class 2: 140 V/ 2.5C)
Fe
CuNi

Iron/Copper-Nickel
(special: 1.1 C)
(standard: 2.2 C)
Fe
CuN

TX
Copper/Copper-Nickel TX
25 C up to + 100 C (Class 1: 30 V/ 0.5 C) 0 C up to + 100 C
(Class 2: 60 V/ 1.0 C)
Cu
CuNi

Copper/Copper-Nickel
(special: 0.5 C)
(standard: 1.0 C)
Cu
CuNi

EX
Nickel-Chromium/Copper-Nickel EX
Nickel-Chromium/Copper-Nickel
- 25C up to + 200 C (Class 1: 120 V/ 1.5 C) 0 C up to + 200 C
( 1.7 C)
(Class 2: 200 V/ 2.5C)
NiCr
CuNi

NiCr
Ni

KX
Nickel-Chromium/Nickel-Aluminium KX
Nickel-Chromium/Nickel-Aluminium
- 25 C up to + 200 C (Class 1: 60 V/ 1.5 C) 0 C up to + 200 C
( 2.2 C)
(Class 2: 100 V/ 2.5 C)

+N

+ NICKEL-CHROMIUM
- NICKEL-ALUMINIUM

+ NICKEL-CHROMIUM-SILICONE
- NICKEL-SILICONE

1) In all standards the basic e.m.f.


values of the same thermocouple
type are identical
2) Following Standards are corresponding with the IEC-Standard 60584
DIN 43722
BS 4937 part 20 + 30
NFC 32-424
JIS C 1610 section 1

 E2

KCB
Copper/Copper-Nickel
0 C up to + 100 C (Class 1:-------------------------)
(Class 2: 100V/ 2.5 C)
Iron/Copper-Nickel VX
KCA
0C up to + 150 C (Class 1:------------------------) ISA RP 1.1
(Class 2: 100V/ 2.5 C) 0 C up to + 100 C
KX
KCB
KCA
NiCr
Cu
Fe
Ni
CuNi CuNi
NX
Nickel-Chromium-Silicone
Nickel-Silicone
- 25 C up to + 200 C (Class 1: 60 V/ 1.5 C)
(Class 2: 100 V/ 2.5 C)

NiCr
Ni
Copper/Copper-Nickel
( 2.2 C)
Cu
CuNi

NC
0C up to + 150 C

Copper/Copper-Nickel
(Class 1:------------------------)
(Class 2: 100V/ 2.5 C)
NX
NC
CuCrSi
Cu
NiSi
CuNi
Temperature ranges and tolerances to IEC 60584. The identication system of ANSI does not
part 3, July 1989.
differ between extension and compensating
Colour coding for conductors and outer sheaths to cables; all materials are marked X.
IEC 60584. part 3, July 1989

Besides the identication letter of the thermocouple type, extension cables are identied by X
compensating cables by C

For BX the temperature range and tolerance


have to be agreed upon between end-user
and manufacturer.

The colour coding of BC, NX and NC is according


to DIN 43722.

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Appendix
Table 2:

Electrical characteristics of conductors (approx. values)


Code

Standard

x mm
m

Volume resistivity

(+) leg

(-) leg

(+) leg

Loop inductance
mH/km

(-) leg

IEC

RPCA/SPCA

RNCA/SNCA

0.017

0.12

IEC

RPCB/SPCB

RNCA/SNCA

0.017

0.12

ANSI

SPX

SNX

0.017

0.12

IEC

BPC

BNC

0.017

0.017

ANSI

BPX

BNX

0.125

0.017

IEC

JPX

JNX

0.12

0.49

ANSI

JPX

JNX

0.12

0.49

IEC

TPC

TNC

0.017

0.49

ANSI

TPX

TNX

0.017

0.49

IEC

EPX

ENX

0.72

0.49

ANSI

EPX

ENX

0.72

0.49

IEC

KPX

KNX

0.72

0.27

IEC

KPCB

KNCB

0.017

0.49

IEC

KPCA

KNCA

0.12

0.51

ANSI

KPX

KNX

0.72

0.27

ISA

VPX

VNX

0.017

0.49

IEC

NPX

NNX

0.98

0.34

IEC

NPC

NNC

0.017

0.52

ANSI

NPX

NNX

0.98

0.34

Table 3: Loop resistance at 20 C (nominal value in /km)


Thermocouple

Conductor material
IEC 60584

ANSI MC 96.1
solid

Conductor size
0.5 mm
0.8 mm

0.8 mm

1.0 mm

1.3 mm

1.5 mm

1.02 mm 1.13 mm 1.29 mm 1.38 mm

R/S

RC/SC

SX

282

173

141

109

94

...

BX

293

179

148

112

98

BC

...

70

43

35

27

23

JX

JX

1257

769

628

483

418

TX

TX

1044

639

522

402

348

EX

Ex

2493

155

1246

958

831

KX

KX

2039

1248

1020

785

680

KCB

VX*

1044

639

522

402

348

KCA

...

1298

794

649

499

433

NX

...

2719

1663

1359

1046

906

NC

...

1106

677

553

425

369

* VX acc. to ISA RP 1.1


KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 E3

Appendix
Appendix II: Colour Codes
1 Colour code of instrumentation and instrumentation control cables acc. to EN 50288-7
1.2

Colour code of standardized product programme


Cabling element
Core 1)

Pair 2)

Triple 2)

--

black/white

black/white/red

Rated voltage

300 V

continuously numbered on white core 1, 2, 3..


for multi-element cables,
starting with 1 in the centre
black

500 V

1)
2)

black/blue

continuously numbered 1, 2, 3 ..
for multi-core cables,
starting with 1 in the centre

black/blue/red

continuously numbered on blue core 1, 2, 3..


for multi-element cables,
starting with 1 in the centre

If specified green-yellow core principally applied as last element in the outer layer
Identification scheme for elements with and without individual screen

1.3

Other colour codes

Other colour codes on request

 E4

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Appendix
Appendix III: Common test methods for cables under fire conditions
1 Reaction to Fire - IEC and corresponding European Standards
IEC Standard
Cenelec Standard
No.
IEC 60332

Title
Test on electric and optical cables under fire
conditions

No.
EN 60332-

-1-1

-1-2
-1-3

Test on a single vertical insulated wire or cable


- Apparatus
- Procedure

- Procedure for determination of flaming

droplets / particles

1-1
1-2
1-3

IEC 60332

Tests on electric cables under fire conditions

EN 60332-

-2-1

-2-2

Test on a single vertical insulated wire or


cable - Apparatus
Test on a single vertical insulated wire or
cable - Procedure
Tests on bunched wires or cables
Apparatus
Procedures Category A F/R
Procedures Category A
Procedures Category B
Procedures Category C
Procedures - small cables Tests on gases evolved during combustion
of materials from cables
Determination of amount of halogen acid gas
Determination of degree of acidity of gases
evolved during the combustion of materials
taken from electric cables by measuring pH
and conductivity


-1

-2-1

-2-2

-2-3

-2-4

-2-5
EN 50267

IEC 60332-

3

-10

-21

-22

-23

-24

-25
IEC 60754

-1
-2

IEC 61034

-1
-2

Measurement of smoke density of cables


burning under defined conditions
Test apparatus
Test procedure and requirements

2-1
2-2

EN 50266

-1
-2-1

-2-2

-2.3

EN 61034

-1
-2

Title
Test on electrical and optical cables under
fire conditions
Test for vertical flame propagation for a
single insulated wire or cable
- Apparatus
- Procedure for 1 kV pre-mixed flame
- Procedure for determination of flaming
droplets / particles
Test for vertical flame propagation for a
single small insulated wire or cable
- Apparatus
- Procedure for diffusion flame
Test for vertical flame spread of vertically
mounted bunched wires o. cables
Apparatus
Procedures - Category A F/R
Procedures - Category A
Procedures - Category B
Procedures - Category C
Procedures - small cables Tests on gases evolved during combustion of
materials from cables
Apparatus
Procedures - Determination of the amount of
halogen acid gas
Procedures - Determination of degree of acidity
of gases for materials by measuring pH and
conductivity
Procedures - Determination of degree of acidity
of gases for cables by determination of the
weighted average of pH and conductivity
Measurement of smoke density of cables burning
under defined conditions
Apparatus
Test procedure and requirements

2 Resistance to fire (IEC 60 331)


IEC 60331

-11

-21

-22

-23
-25

IEC Standard

Tests for electric cables under fire


(under
consideration)
conditions Circuit Integrity
Apparatus Fire alone at temperature of at
least 750 C
Procedures and requirements Cables of
rated voltage up to and including 0,6/1 kV
Procedures and requirements Cables
of rated voltage greater than 1 kV (under
consideration)
Proc. and requirements Electric data cables
Proc. and requirements Optical fibres
cables

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

CENELEC Standard

(under consideration)

 E5

Appendix
Appendix IV: Identification of instrumentation and thermocouple cables
1

The type designations of KERPENs instrumentation- and thermocouple cables


are read as follows:
type abbreviation
number of cabling elements
type of cabling element
conductor size in mm (stranded conductors) or conductor diameter in mm (solid conductors)
followed by (when and where applicable):
type of conductor material (for thermocouple cable only, see table 1)
abbreviation for cables with circuit integrity properties
Individual screening of pairs and triples
rated voltage
standard

Abbreviation code
Cable type
RE-
RT-

Instrumentation and instrumentation control cable


Thermocouple extension or compensating cable

Metal cladding of conductor


-v
Copper conductor, tinned
Insulation and/or sheath materials
Y
Insulation, inner or outer sheath of polyvinylchloride (PVC)

Yw

Insulation, inner or outer sheath made of heat resistant polyvinylchloride (PVCw)

Yv
2Y
2X
H
2G
4Y

Outer sheath made of polyvinylchloride of increased thickness


Insulation, inner or outer sheath made of polyethylene (PE)
Insulation made of cross linked polyethylene (XLPE)
Inner or outer sheath made of halogen-free, flame retardant compound (LSZH)
Insulation made of silicone (Sil)
Covering made of polyamide (nylon)

Screening
(ST)
(L)
C
K
PiMF
TiMF
(C)

Static screen made of laminated plastic tape laminated with aluminium


Longitudinally applied aluminium foil, one or both sides plastic-coated
Braid made of tinned or untinned copper wires over the cable core
Wrapping made of copper foil
Pair in Metal Foil
Triple in Metal Foil
Braid of tinned or untinned copper wires over a single cabling element

Metal sheath
M
Sheath made of lead
Mz
Sheath made of lead alloy

 E6

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Appendix
Armour
SWA
RG
FG
B
Q

Galvanized round steel wires


Galvanized round steel wires with counter helix made of galvanized steel tape
Galvanized flat steel wires with counter helix made of galvanized steel tape
Double layer made of galvanized steel tapes
Braid made of galvanized round steel wires

Other properties
CI
Circuit Integrity (resistance to fire)

-fl

Increased flame retardancy; meeds requirements for IEC 60332-3-24 (cat. C) fulfilled

Cable core filled with petrojelly

1)

Type of cabling elements


The type of cabling elements used are indicated by figures or by figures with additional information for
individual screened cabling elements

Core

no figure

Pair

Triple

Individual screened pair

2 PiMF

Individual screened triple

3 TiMF

Examples:
Instrumentation cable RE, 24 triples 3, conductor size 1.3 mm, insulation of PE 2Y, individual TiMF
and overall screen (St), inner sheath of PVC Y, lead sheath M, inner sheath made of PVC Y, steel
wire armour SWA, outer sheath of PVC Y-fl, rated voltage 300 V, standard EN 50288-7

RE-2Y(St)YMYSWAY-fl 24 x 3 x 1.3 mm TiMF 300 V EN 50288-7

Thermocouple extension RT-, 8 pairs 2, conductor diameter 0,8 mm, conductor material KX, insulation
of heat resistant PVC Yw, overall screen (St), inner sheath made of heat resistant PVC Yw, steel wire
armour SWA, outer sheath made of heat resistant PVC Yw, rated voltage 300 V, standard EN 50288-7

RT-Yw(St)YwSWAYw-fl 8 x 2 x 0.8 mm KX 300 V EN 50288-7

Instrumentation control cable RE-, halogen-free with Circuit Integrity CI, 8 cores, conductor size 2.5
mm, insulation of XLPE 2X, overall screen (St), outer sheath made of halogen-free, flame retardant
compound H, rated voltage 500 V, standard EN 50288-7

RE-2X(St)H 8 x 2.5 mm CI 500 V EN 50288-7

Instrumentation cable RE, 12 pairs 2, conductor size 1.5 mm, insulation made of XLPE 2X, individual
screen PiMF, multi layer sheath (L)2Y, steel wire armour SWA, outer sheath made of PE 2Y, rated voltage 300 V, standard EN 50288-7

1)

RE-2X(L)2Y4YSWA2Y 12 x 2 x 1.5 mm PiMF 300 V EN 50288-7


This property is indicated on the outer sheath of PVC-sheathed cables via the marking RP

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 E7

Appendix
Appendix V: Tables
Table 4:
Length

Conversion of general units

1 mil

1 inch (in)

1 foot (ft.)

1 yard (yd)

0.0254

Area
mm

1 circ. mil (CM)

mm

1 MCM

0.305

1 square inch (in )

0.914

1 square foot (ft2)

0.0929

m2

1 mile (mi.)

1.61

km

1 square yard (yd )

0.836

m2

1 statute mile (mi.)

1.61

km

1 square mile (sq.mi.)

2.59

km2

1 intern. naut. mile (sm)

1.852

km

25.4

0.0005067

mm2

0.5067

mm2

645.16

mm2

Volume
1 cubic inch (m3)

1 cubic foot (ft )

0.0283

m3

1 cubic yard (yd3)

0.765

m3

1 barrel

1 US gallon (US gal)

3.79

1 UK gallon (UK gal)

4.55

Force
1 poundal (pdl)

16.39

cm3

159

0.1 38

Mass
1 ounce (oz)

0.0284

kg

1 pound-force (lbf)

4.448

1 pound (lb)

0.454

kg

1 Brit. ton-force

1 Brit. ton (long ton)

1016

kg

1 US ton (short ton)

907

kg

1 Brit. therm. unit (B U)

1055

1 Brit. therm. unit

9964

Power

Energy

1 horsepower (H.P.)

0.746

kW

0.000293

kWh

Pressure
1 bf/in2 (psi)

0.06895

bar

1 lbf/ft2

0.000479

bar

0.0000532 bar

5.32

0.703

kp/cm2

0.0703 at

1 lbf/yd

1 lbf/in2 (psi)

6.895
47.9

N/m2
N/m2
N/m2

Electrical Unit per Length


1 f per mile

0.62

F/km

1 M per mile

1.61

M x km

1 decibel per mile

0.62

dB/km

1 pf per foot

3.28

pF/m

1 decibel per 1000 ft.

3.28

dB/km

1 per 1000 ft.

3.28

/km

Abbreviations for multiples and submultiples


prefix

abridged
multiple
mark
power name

prefix

abridged
mark

sub multiple
power
name

Tera

1012 billion *

Piko

1012

billionth *

Giga

109

milliard *

Nano

109

milliardth *

Mega

10

million

Mikro

10

millionth

Kilo

103

thousand

Milli

103

thousanth

Hekto

10

hundred

Zenti

10

hundredth

Deka

da

101

ten

Dezi

101

tenth

*In USA 109 indicates a billion and 1012 indicates a trillion

 E8

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Appendix
Table 5: Conductor comparison AWG - metric
Solid plain annealed copper conductors
Conductor size

Conductor-
(mm)

AWG

1)

Metric (mm)

No. of wires

30

0.051

0.254

---

---

361

28

0.081

0.320

---

---

228

69.3

26

0.128

0.404

---

---

154

46.9

24

0.205

0.511

---

---

97.6

29.7

22

0.324

0.643

---

---

56.3

17.2

---

0.5

0.8

36.8

11.2

---

---

20

0.517

0.813

---

---

35.2

10.7

---

0.75

1.0

25.0

7.6

---

---

18

0.82

1.02

---

---

22.3

6.8

---

1.13

18.5

5.6

---

---

16

1.3

1.29

---

---

14.0

4.3

---

1.5

1.37

12.3

3.76

---

---

14

2.1

1.63

---

---

8.79

2.67

---

2.5

1.76

7.56

2.31

---

---

12

3.3

2.05

---

---

5.52

1.68

---

2.26

4.70

1.43

---

---

Stranded plain annealed copper conductors


Conductor size



3)

4)

1)
2)

Electrical resistance2)
EN 50288-73)
UL 134)
(/km)
(/1000 ft.)
(/km)
(/1000 ft.)

Conductor-
(mm)

110

Electrical resistance2)
EN 50288-73)
UL 134)
(/km)
(/1000 ft.)
(/km)
(/1000 ft.)

AWG

Metric1) (mm)

No. of wires

24

0.205

0.579

---

---

91.1

27.8

22

0.327

0.729

---

---

57.6

17.6

---

0.5

0.9

36.8

11.2

---

---

20

0.517

0.919

---

---

35.8

11.0

---

0.75

1.11

25.0

7.6

---

---

18

0.82

1.16

---

---

22.8

6.9

---

1.29

18.5

5.6

---

---

16

1.3

1.46

---

---

14.2

4.36

---

1.5

1.59

12.3

3.76

---

---

14

2.1

1.85

---

---

8.94

2.72

---

2.5

2.01

7.56

2.31

---

---

12

3.3

2.32

---

---

5.63

1.72

---

2.58

4.70

1.43

---

---

Sizes acc. to EN 50288-7 printed in bold and italic letters


The value for the electrical resistance is given for 20 C (68.0 F)
The value for the electrical resistance acc. to EN 50288-7 is for the finished cables with multi pairs/triples
The value for the electrical resistance acc. to UL 13 is calculated for one pair/triple and an assembly of pairs/triples

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 E9

Appendix

Instrumentation Cable

EN 50288-7

Sa

Flame Retardant, Sunlight Resistant

70C / 300 V

Multi-Pair, PVC Insulation , Individual & Collective Screen, Lead Sheath, Armour, PVC Sheath
RE-Y(St)YMYSWAY- PiMF

Application
For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group
II classied areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity
supply.
Recommended for direct burial, especially in presence of oil and aggressive chemical substances.
Construction
Conductor ...................... plain annealed copper, stranded, sizes: 0.5mm, 0.75mm,
1.0mm, 1.3mm, 1.5mm
Insulation ....................... polyvinyl chloride PVC
Colour code ................... black / white, continuously numbered on white core (1, 2..) for
multipairs
Individual shield ............. 24 m aluminium / PETP tape over solid tinned copper drain
wire, 0.6 mm , plastic tape under and above screen
Wrapping ....................... at least 1 layer of plastic tape
Collective screen ........... 24 m aluminium / PETP tape over 7-stranded tinned copper
drain wire, 0.5mm
Inner sheath .................. polyvinyl chloride PVC, black
Metal sheath .................. lead
Bedding ......................... polyvinyl chloride PVC, black
Armour ........................... galvanized round steel wires
Outer sheath .................. polyvinyl chloride PVC, black; blue for intrinsically safe systems
Cable marking ............... ICON by KERPEN INSTRUMENTATION CABLE 300 V RP
EN 50288-7 CE Length marking

Technical data

ple
Abbreviations

Flame propagation:
Test on single cable:
IEC 60332-1-2
Test on bunched cables: IEC 60332-3-24 (Cat. C)

Temperature range:
- 30 C up to + 70 C
(during operation)
- 5 C up to + 50 C
(during installation)

Sunlight resistance:
Oil resistance:

Min. bending radius:


15 x cable-

UL 1581 section 1200


ICEA S-82-552

Electrical data at 20 C

RE2Y
(St)
Y
M
Y
SWA
Y
-
PiMF

Instrumentation Cable
insulation of PE
collective screen
outer sheath of PVC
sheath of lead
bedding of PVC
steel wire armour
outer sheath of PVC
with reduced ame propagation
pair in metal foil

Character

Unit

Conductor size

nom.

mm

0.5

0.75

1.0

1.3

1.5

Conductor resistance

max.

/km

36.7

25.0

18.5

14.2

12.3

Insulation resistance

min.

M x km

Mutual capacitance

max.

nF/km

190

190

190

200

200

Inductance

max.

mH/km

L/R (ratio)

max.

H/

25

25

25

40

40

Test voltage
core : core
core : screen
Operating voltage

 E10

U(rms)

1500

U(rms)

300

Phone: +49 24 02 17 307

1500

Internet: www.kerpen.com

Transfer to third parties only by authority of KERPEN GmbH & Co. KG


Printing errors excepted. Subject to alteration

Creator: PM-I/DU
Page 1/3

File: 7E01030000_RE_Y(St)YMYSWAY__PIMF_RM_REV_00.doc

100

U(rms)

KERPEN GmbH & Co. KG

Date of issue: xx.xx.xxxx


Update: xx.xx.xxxx

Values

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Appendix

Instrumentation Cable

Sa

EN 50288-7

Flame Retardant, Sunlight Resistant

70C / 300 V

Multi-Pair, PVC Insulation , Individual & Collective Screen, Lead Sheath, Armour, PVC Sheath
RE-Y(St)YMYSWAY- PiMF
Geometrical data
No. of
RT of inpairs
sulation
nom.
(mm)

RT of
inner
sheath

RT of
lead
sheath

over
lead
sheath

RT of
bedding

of
armour
wire

RT of
outer
sheath

Overall

Weight

Part No.

nom.
(mm)

nom.
(mm)

approx.
(mm)

nom.
(mm)

nom.
(mm)

nom.
(mm)

approx.
(mm)

approx.
kg/km

outer sheath
black

0.5 mm/7

0.35

1.00

1.00

11.0

1.00

0.90

1.50

17.8

826

7800E166

0.35

1.00

1.00

12.3

1.00

0.90

1.60

19.3

959

7800E169

0.35

1.00

1.00

13.3

1.00

1.25

1.60

21.0

1160

7800E172

0.35

1.00

1.10

14.5

1.00

1.25

1.60

22.2

1302

7800E175

0.35

1.00

1.10

15.2

1.00

1.25

1.70

23.1

1409

7800E178

10

0.35

1.00

1.10

17.0

1.00

1.25

1.70

24.9

1598

7800E181

12

0.35

1.00

1.20

17.9

1.00

1.25

1.70

25.8

1746

7800E184

16

0.35

1.00

1.20

19.9

1.00

1.25

1.80

28.0

2007

7800E187

20

0.35

1.00

1.30

21.9

1.00

1.25

1.80

30.0

2299

7800E190

24

0.35

1.00

1.30

23.5

1.00

1.60

1.90

32.5

2711

7800E193

0.38

1.00

1.00

11.8

1.00

0.90

1.50

18.6

894

7800E196

0.38

1.00

1.00

13.3

1.00

1.25

1.60

21.0

1158

7800E199

0.38

1.00

1.10

14.6

1.00

1.25

1.60

22.3

1326

7800E202

0.38

1.00

1.10

15.7

1.00

1.25

1.70

23.6

1456

7800E205

0.38

1.00

1.10

16.6

1.00

1.25

1.70

24.5

1553

7800E208

10

0.38

1.00

1.20

18.7

1.00

1.25

1.80

26.8

1852

7800E211

12

0.38

1.00

1.20

19.5

1.00

1.25

1.80

27.6

1952

7800E214

16

0.38

1.00

1.30

21.9

1.00

1.25

1.80

30.0

2324

7800E217

20

0.38

1.00

1.30

24.0

1.00

1.60

1.90

33.0

2767

7800E220

24

0.38

1.00

1.40

26.0

1.20

1.60

2.00

35.6

3191

7800E223

0.40

1.00

1.00

12.5

1.00

0.90

1.60

19.5

964

7800E226

0.40

1.00

1.10

14.4

1.00

1.25

1.60

22.1

1304

7800E229

0.40

1.00

1.10

15.6

1.00

1.25

1.70

23.5

1447

7800E232

0.40

1.00

1.10

16.8

1.00

1.25

1.70

24.7

1577

7800E235

0.40

1.00

1.20

18.0

1.00

1.25

1.70

25.9

1778

7800E238

10

0.40

1.00

1.20

20.1

1.00

1.25

1.80

28.2

2033

7800E241

12

0.40

1.00

1.30

21.2

1.00

1.25

1.80

29.3

2240

7800E244

16

0.40

1.00

1.30

23.7

1.00

1.60

1.90

32.7

2764

7800E247

20

0.40

1.00

1.40

26.1

1.20

1.60

2.00

35.7

3251

7800E250

24

0.40

1.00

1.50

28.3

1.20

1.60

2.10

38.1

3666

7800E253

0.75 mm/7

1.0 mm/7

ple

RT = Radial Thickness

KERPEN GmbH & Co. KG

Date of issue: xx.xx.xxxx


Update: xx.xx.xxxx

Phone: +49 24 02 17 307

Internet: www.kerpen.com

Transfer to third parties only by authority of KERPEN GmbH & Co. KG


Printing errors excepted. Subject to alteration

File: 7E01030000_RE_Y(St)YMYSWAY__PIMF_RM_REV_00.doc

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

Creator: PM-I/DU
Page 2/3

 E11

Appendix

Instrumentation Cable

Sa

EN 50288-7

Flame Retardant, Sunlight Resistant

70C / 300 V

Multi-Pair, PVC Insulation , Individual & Collective Screen, Lead Sheath, Armour, PVC Sheath
RE-Y(St)YMYSWAY- PiMF
Geometrical data
No. of
RT of inpairs
sulation

RT of
inner
sheath

RT of
lead
sheath

over
lead
sheath

RT of
bedding

of
armour
wire

RT
of outer
sheath

Overall

Weight

Part No.

nom.
(mm)

nom.
(mm)

nom.
(mm)

approx.
(mm)

nom.
(mm)

nom.
(mm)

nom.
(mm)

approx.
(mm)

approx.
kg/km

outer sheath
black

0.45

1.00

1.10

14.1

1.00

1.25

1.60

21.8

1180

7800E256

0.45

1.00

1.10

15.6

1.00

1.25

1.70

23.5

1461

7800E259

0.45

1.00

1.10

16.9

1.00

1.25

1.70

24.8

1614

7800E262

0.45

1.00

1.20

18.4

1.00

1.25

1.70

26.3

1838

7800E265

0.45

1.00

1.20

19.5

1.00

1.25

1.80

27.6

2019

7800E268

10

0.45

1.00

1.30

22.1

1.00

1.25

1.80

30.2

2388

7800E271

12

0.45

1.00

1.30

23.1

1.00

1.60

1.90

32.1

2542

7800E274

16

0.45

1.00

1.40

26.0

1.20

1.60

2.00

35.6

3350

7800E277

20

0.45

1.00

1.50

28.7

1.20

1.60

2.10

38.5

3875

7800E280

24

0.45

1.20

1.60

31.5

1.20

1.60

2.10

41.3

4302

7800E283

0.45

1.00

1.10

14.5

1.00

1.25

1.60

22.2

1283

7800E286

0.45

1.00

1.10

16.1

1.00

1.25

1.70

24.0

1510

7800E289

0.45

1.00

1.20

17.6

1.00

1.25

1.70

25.5

1743

7800E292

0.45

1.00

1.20

19.0

1.00

1.25

1.80

27.1

1923

7800E295

0.45

1.00

1.20

20.2

1.00

1.25

1.80

28.3

2088

7800E298

10

0.45

1.00

1.30

22.9

1.00

1.25

1.90

31.2

2504

7800E301

12

0.45

1.00

1.30

23.9

1.00

1.60

1.90

32.9

2864

7800E304

16

0.45

1.00

1.40

27.0

1.20

1.60

2.00

36.6

3493

7800E307

20

0.45

1.00

1.50

29.8

1.20

1.60

2.10

39.6

4077

7800E310

24

0.45

1.20

1.60

32.7

1.20

2.00

2.20

43.5

4551

7800E313

1.3 mm/7

1.5 mm/7

ple

RT = Radial Thickness

KERPEN GmbH & Co. KG

Date of issue: xx.xx.xxxx


Update: xx.xx.xxxx

Phone: +49 24 02 17 307

 E12

Internet: www.kerpen.com
Creator: PM-I/DU
Page 3/3

File: 7E01030000_RE_Y(St)YMYSWAY__PIMF_RM_REV_00.doc

Transfer to third parties only by authority of KERPEN GmbH & Co. KG


Printing errors excepted. Subject to alteration

KERPEN GmbH & Co. KG

09.2006 Printing errors excepted. Subject to alterations

Appendix
Notes:

KERPEN GmbH & Co. KG 09.2006 Printing errors excepted. Subject to alterations

 E13

CABLE PROGRAMME

Instrumentation and control

cables

Thermocouple extension and

compensating cables

Power cables

(Low and Medium


Voltage)

Telecommunication cables

Data and Bus cables

COPPER AND FIBRE OPTIC

Mining Cables

KERPEN GmbH & Co. KG


A Member of the LEONI Group
Zweifaller Str. 275-287 D-52224 Stolberg, Germany

www.kerpen-industrial.com email: industrial@kerpen.com


Tel: +49 24 02 / 17 307 Fax: +49 24 02 / 7 55 90

 E14

KERPEN GmbH & Co. KG

PM Industrial/en/Rev.03/2006

cables for special applications

09.2006 Printing errors excepted. Subject to alterations