Anda di halaman 1dari 3

10/100 Four Port Ethernet Magnetics Module

HB8xx-Schematic #1, Rev. H

16 Aug 01

(xx equals one of the circuit numbers in the table below the schematic.)
Other circuit schematics are available. Please contact us at (800) 511-7308 or visit
our web site at www.trans-power.com.
1.10 Max

0.004
40 Surfaces

0.050 Typ

0.015

0.230 Max

0.010

0.030

0.100
0.47 Max

0.625 Max

0.580

0.050(38X)
0.950
All dimensions are 0.005 unless otherwise noted.

Standard Features:

HB8xx 10/100
Schematic #1
Typical RX Circuit
1:1

Chip

Typical TX Circuit

Cable

-Four port interface for 10/100Mbps Ethernet applications


-Compliant with IEEE 802.3 and ANSI X3.263 Standards
-OCL of 350uH min. when biased at 8mA from 0o C to 70o C
-Surface mount package designed for reflow process
(240oC peak)
-Dielectric Isolation is 1500Vrms minimum
-Tube or Tape & Reel packaging available

See Table

Important

Part Number Table


Part
Number

Suggested Pad Layout

TX Turns Ratio
(Chip:Cable)

HB821

2:1

HB826

1:1

HB833

1.25:1

HB839

1.41:1

See next two pages to choose a signal routing and


complete the part number. If an alternate signal routing
is chosen, the part number will be a combination of the
part number chosen in the table to the left and a signal
routing number from one of the next two pages. See
next page for an example.
10/100 ETHERNET ELECTRICAL CHARACTERISTICS @ 25C
Inductance:

350uH Min with 8mA DC Bias, 0C - 70C

Rise time (10 - 90%):

2.5 nSec typical

Dielectric Isolation:

1500 Vrms minimum

Frequency

1401

Insertion Loss
(dB MAX) *

Return Loss
(dB MIN)

Crosstalk
Attenuation
(dB MIN)

TX CMRR
(dB MIN)

RX CMRR
(dB MIN)

.100 MHz - .999 MHz

1.0

18.0

43.0

46.0

1.0 MHz - 15.0 MHz

0.3

18.0

43.0

46.0

35.0
35.0

15.1 MHz - 60.0 MHz

0.6

18.0

43.0

46.0

35.0

60.1 MHz - 80.0 MHz

1.1

15.0

38.0

42.0

33.0

80.1 MHz - 100.0 MHz

1.1

12.0

38.0

42.0

33.0

* Indicated Insertion Loss refers to magnetic circuitry only.

2300

Transpower Technologies, Inc., Park Center West Building, 9805 Double R Blvd, Suite #100, Reno, NV 89511
(775) 852-0140 (800) 511-7308 FAX: (775) 852-0145
Page 1 of 3

10/100 Four Port Ethernet Magnetics Module


HB8xx-Schematic #1, Rev. H

16 Aug 01

(xx equals one of the circuit numbers in the table below the schematic.)
Other circuit schematics are available. Please contact us at (800) 511-7308 or visit
our web site at www.trans-power.com.

RD1+

RD1-

TD1-

TD1CT

TD1+

1:1

TX

1:1

1:1

TX

40

RX1+

TD4+

40

TX4+

39

RX1-

TD4-

39

TX4-

38

TX1CT

D4CT

38

X4CT

37

TX1+

RD4+

37

RX4+

36

TX1-

RD4-

36

RX4-

35

RX3-

40

RX1+

RD1+

39

RX1-

RD1-

38

TX1-

TD1CT

37

TX1CT

TD1+

36

TX1+

TD1-

TX

1:1

1:1

35

TX2-

RD3-

34

TX2+

RD3+

34

RX3+

TD2CT

33

TX2CT

D3CT

33

X3CT

TX2CT

RD2-

32

RX2-

TD3-

32

TX3-

31

TX2+

RD2+ 10

31

RX2+

TD3+ 10

31

TX3+

30

RX3+

RD3+ 11

30

RX3+

TD2+ 11

30

TX2+

29

RX3-

RD3- 12

29

RX3-

TD2- 12

29

TX2-

28

TX3-

TD3CT 13

28

TX3CT

D2CT 13

28

X2CT

TD3CT 14

27

TX3CT

TD3+ 14

27

TX3+

RD2+ 14

27

RX2+

TD3+ 15

26

TX3+

TD3- 15

26

TX3-

RD2- 15

26

RX2-

25

RX4+

TD4- 16

25

TX4-

RD1- 16

25

RX1-

24

RX4-

TD4+ 17

24

TX4+

RD1+ 17

24

RX1+

23

TX4-

TD4CT 18

23

TX4CT

D1CT 18

23

X1CT

TD4CT 19

22

TX4CT

RD4- 19

22

RX4-

TD1- 19

22

TX1-

TD4+ 20

21

TX4+

RD4+ 20

21

RX4+

TD1+ 20

21

TX1+

35

RX2+

TD2-

34

RX2-

TD2+

33

TX2-

32

TD2+ 10

RD2+

RD2-

TD2-

TD2CT

TX

1:1

RD3+ 11
RD3- 12
TD3- 13

TX

1:1

RD4+ 16
RD4- 17
TD4- 18

TX

TD1+

40

TX1+

RD1+

TD1CT

39

TX1CT

RD1-

TD1-

38

TX1-

TD1-

RD1+

37

RX1+

TD1CT

RD1-

36

RX1-

TD2+

35

TX2+

TD2CT

34

TX2CT

TD2-

33

TX2-

1:1

TX

1:1

TX2CT

TX2CT

TD2+

34

TX2+

TX2+

TD2-

TX1+

TD2-

35

TX2-

TD2CT

34

TD2+

33

RD3- 12

TX3-

TD3- 13

27

RX3+

26

RD3- 20

35

36

TX3CT

RD4+ 19

28

1:1

TX1CT

TD2CT

TD1+

29

TD4- 18

36

TD1-

TD3- 13

TD4CT 17

TX1CT

TD3CT 12

TX

TX1-

TD1CT

37

RD2- 10

TD4+ 16

37

RD3+ 11

RD4- 15

TX1+

32

RX2+

RD2+

31

RX2-

RD2- 10

RX3+

RD3+ 11

29

RX3-

RD3- 12

28

TX3-

TD3+ 13

TD3CT 14

27

TX3CT

RX3-

TD3+ 15

26

25

TX4+

TD4- 16

24

TX4CT

23

TX4-

TX

TD4CT 17
TD4+ 18

22

RX4+

RD4+ 19

21

RX4-

RD4- 20

HB8xx-3 Schematic

TX

1:1

TX

TX

1:1

30

1:1

1:1

RX1-

TD1+

RD2+

TX

38

TX1-

1:1

1:1

RX1+

38

TX

1:1

39

TX

TX

40

RD1-

TX3+

1:1

1:1

TX

HB8xx-2 Schematic
(Note position of CMCs)

RD1+

RX2-

RD3+ 14

1:1

RX1-

30

TX

TX

RX1+

31

RD2- 10
TD3+ 11

TX

39

RX2+

1:1

40

32

RD2+

1:1

HB8xx-1 Schematic

HB8xx Schematic

TX

TX

33

TX2-

32

RX2+

31

RX2-

30

RX3+

29

RX3-

28

TX3+

TD3- 14

27

TX3-

TX3+

TD3CT 15

26

TX3CT

25

TX4-

TD4CT 16

25

TX4CT

24

TX4CT

TD4+ 17

24

TX4+

23

TX4+

TD4- 18

22

RX4+

RD4+ 19

21

RX4-

RD4- 20

HB8xx-4 Schematic

1:1

TX

TX

1:1

23

TX4-

22

RX4+

21

RX4-

HB8xx-5 Schematic

Important: If you chose the HB821 part number from the table on the prior page and
want the HB8xx-3 signal routing, the part number would be HB821-3.
Transpower Technologies, Inc., Park Center West Building, 9805 Double R Blvd, Suite #100, Reno, NV 89511
(775) 852-0140 (800) 511-7308 FAX: (775) 852-0145
Page 2 of 3

10/100 Four Port Ethernet Magnetics Module


HB8xx-Schematic #1, Rev. H

16 Aug 01

(xx equals one of the circuit numbers in the table below the schematic.)
Other circuit schematics are available. Please contact us at (800) 511-7308 or visit
our web site at www.trans-power.com.

RD1+

RD1-

TD1CT

TD1+

TD1-

TD2+

TD2-

TD2CT

RD2+

1:1

TX

TX

1:1

RD2- 10
RD3+ 11

1:1

RD3- 12
TD3CT 13

TX

TD3+ 14
TD3- 15
TD4+ 16

TX

TD4- 17
TD4CT 18
RD4+ 19

1:1

RD4- 20

40

TX1-

RD1+

39

TX1+

RD1-

38

TX1CT

TD1CT

37

RX1-

TD1+

36

RX1+

TD1-

35

TX2-

TD2-

34

TX2+

TD2+

33

TX2CT

TD2CT

32

RX2-

RD2-

31

RX2+

RD2+ 10

TX3-

RD3+ 11

29

TX3+

RD3- 12

28

TX3CT

27

RX3-

TD3+ 14

26

RX3+

TD3- 15

TX4-

TD4- 16

24

TX4+

TD4+ 17

23

TX4CT
RX4-

RD4- 19

21

RX4+

RD4+ 20

RX1+
RX1-

TD1+

38

TX1+

RD1-

RD1+

TD2-

6
7

TD2+

RD2-

1:1

TD3- 11

TX

12
TD3+ 13
RD3- 14

1:1

RD3+ 15

RX2+

34

RX2-

33

TX2+

RX3+

29

RX3-

28

TX3+

27
26

TX3RX4+

24

RX4-

TD4+ 18

23

TX4+

RD4- 19
RD4+ 20

1:1

38

TX1CT

TD1-

37

TX1-

TD1CT

36

TX1+

TD1+

35

RX2-

TD2-

34

RX2+

TD2CT

33

TX2CT

TD2+

32

TX2-

RD2+

1:1

TX

TX

1:1

31

TX2+

RD2- 10

30

RX3-

RD3+ 11

29

RX3+

RD3- 12

28

TX3CT

TD3- 13

27

TX3-

TD3CT 14

26

TX3+

TD3+ 15

25

RX4-

TD4- 16

24

RX4+

TD4CT 17

23

TX4CT

1:1

TX

TX

TD4+ 18

22

TX4-

RD4+ 19

21

TX4+

RD4- 20

1:1

40

TX1-

39

TX1CT

38

TX1+

37

RX1+

36

RX1-

35

TX2-

34

TX2CT

33

TX2+

32

RX2+

31

RX2-

30

TX3-

29

TX3CT

28

TX3+

27

RX3+

26

RX3-

25

TX4-

24

TX4CT

23

TX4+

22

RX4+

21

RX4-

HB8xx-11 Schematic

TX2-

30

25

TX

1:1

RD1-

32

17

TD4- 16

TX

RD1+

RX1+

TX1-

35

31

RD2+ 10

TX

RX1-

39

37
36

TX

1:1

40

HB8xx-10 Schematic

39

1:1

1:1

TD4CT 18

22

40

TX

TX

TD3CT 13

25

TD1-

TX

30

HB8xx-9 Schematic

1:1

HB826-2 and HB826-13 are designed to


accomodate Auto-MDIX applications.

22
21

HB8xx-13 Schematic
(Note position of CMCs)

TX4-

1401

Important: If you chose the HB821 part number from the table on the prior page and
want the HB8xx-9 signal routing, the part number would be HB821-9.
Transpower Technologies, Inc., Park Center West Building, 9805 Double R Blvd, Suite #100, Reno, NV 89511
(775) 852-0140 (800) 511-7308 FAX: (775) 852-0145
Page 3 of 3

Anda mungkin juga menyukai