Anda di halaman 1dari 48

Your Inspirations. Our Innovations.

UNINTERRUPTIBLE
POWER SUPPLY (UPS)
Protecting Your Data

CATALOGUE
Revision 2012

Table of Contents

Table of Contents
About Us - Company Profile

Online UPS

Professional Series (1P/1P) - Tower

Master Series (1P/1P) - Tower

Master Series (1P/1P) - Combo

10

Master Series (1P/1P) - 2-in-1 Rack/ Tower

12

Master Series (3P/1P) - Tower

16

Master Series (3P/1P) - Rack Mount

18

Master Series (3P/3P) - Tower

21

Power Series (3P/3P)

23

Line Interactive UPS

27

PRO Series

27

Inverter UPS

28

IPS Series

28

Solar UPS

31

PDC Series - DC UPS

31

PCC Series

32

PSI Hybrid Series

33

PSI On-Grid Series

34

PSI Off-Grid Series

35

PSS Series

36

Software & Accessories

37

Appendixz

41

About Us - Company Profile

Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufactured under the brand name PROLiNK since 1991. With more than two decades of professional experience in the
information communications sector, PROLiNK is now renowned as a specialist in its field, especially in area of Backup
UPS products.
Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the
South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its
current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide
the right solutions to meet the needs of both home and business users within each geographical location both
efficiently and effectively.
The companys quest for continuous improvement and quality assurance to its customers has earned us the ISO9001
quality certification since 1999. With its consistently strong commitment to quality, customers can be assured of they
are getting true value - superior quality products at affordable prices.

Our Mission
Accentuate The Best For The E-generation
PROLiNK aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of
modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming
more and more commonplace.
PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our
products are crafted to enhance performance whether you are at work or play our products work harder, while you
work smarter to achieve your desired results with less effort and better efficiency.
Providing value to our consumers whether home or business users, remains a firm commitment of PROLiNK. With
its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions
for their technological needs, while business users are assured of reliable and secure solutions for their network
infrastructure.

Our Vision
Ideas, Innovation and Information
PROLiNK aims to be the key driving force behind technological changes and improvements in both developing and
developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of
innovation, change and improvement so as to provide the next generation of users with products that are suitable for
their technology advanced environments.
The small i in PROLiNK represents ideas, innovation and information three key pillars of growth that drive us
towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries.

About Us - Company Profile

Core Values
Secured Information Management
With more than two decades of professional experience in providing backup power solutions to our customers, we are
able to support our customers with superior technological know-how and expertise, as well as advice on market
trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage
confidential information discreetly.

Innovative Design
Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With
the teams solid experience in the UPS market, customers can be certain that our designs are innovative yet functional,
and suitable for each dynamic market that we have a presence in.

Superior Service Standards


Strict and rigorous testing makes up a huge part of our quality control procedures. We ensure that every item meets
our strict standards from the individual components to the actual finished product.

Total Quality Assurance System


Our products go through careful planning and checks at every stage of the production cycle - from the beginning stages
of product design to the manufacturing and finally the actual delivery of the goods. This guarantees that our customers
receive only the best quality goods of high reliability and durability. Our total quality system has been audited and
approved by globally recognized bodies.

Range of UPS
The wide range of our products gives you an infinite range of solutions:
1. Online UPS
2. Line Interactive UPS
3. Inverter UPS
4. Solar UPS

Online UPS

Professional Series (1P/1P) - Tower

Online Professional Series 1KVA 6KVA


The Professional Series (1P/1P) - Tower is an advanced, affordable on-line double-conversion technology single-phase
UPS system. Professional Series is available with 1000VA to 6000VA models and these offer high reliability for
workstations, server and network equipment.
The Professional Series is designed to protect against power outages, disturbances and spikes. It also provides
high-efficient charger with PFC. High battery charging current and battery extension assembly is available for the long
run time application. In order to supply pure and clean power to sensitive devices, an optional of isolation transformer
can be attached to UPS unit without taking extra space.

True Double-Conversion Online UPS


Wide input voltage range (110~300VAC)
Input Power Factor correction 0.98
Output Power Factor 0.80
Generator compatible
LCD User Interface
RS-232 communication port or mini slot for USB / RS-232 /
AS400 / SNMP communication
Smart battery charger design for optimized battery
performance
Optional isolation transformer available

PRO901S/ L
PRO902S/ L

PRO903S/ L
PRO906S/ L
Small Computer
Network

Local Area
Network (LAN)

Work-Stations

Service

Rear Panel
For 1KVA to 6KVA model

6
9
4
3
2

PRO901S/
PRO902S

5
4
6
6

4
3
2
PRO901L/
PRO902L

8
9

9
1

5
4

8
9

PRO903S/
PRO906S

PRO903L/
PRO906L

1. Output receptacles
2. AC input
3. Input circuit breaker
4. Network/Fax Modem Surge Protection
5. RS-232 communication port /
SNMP intelligent slot
6. External battery connection
(only available for L model)
7. Output terminal
8. Output circuit breaker
9. Fan

Online UPS

Options

RS-232 Port for communication.


AS-400 Card for external alarm signal.
SNMP Card for data communication via network connection.
Output Isolation Transformer.
External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3KVA only)

Full Specifications
MODELS

PRO901S/ L

PRO902S/ L

PRO903S/ L

PRO906S/ L

Capacity

1000 VA/ 800 W

2000 VA/ 1600 W

3000 VA/ 2400 W

6000 VA/ 4800 W

INPUT
Nominal Voltage

208/ 220/ 230/ 240VAC

Voltage Range

110Vac < Vin < 290Vac @ 50% LOAD/ 168Vac < Vin < 300Vac @ 100% LOAD

Nominal Frequency

50 or 60Hz

Frequency Range

40 ~ 70Hz
0.98

Power Factor
OUTPUT
Output Voltage

200/ 208/ 220/ 230/ 240VAC

Static Regulation

3%

1%

Frequency

50Hz or 60Hz auto selection

Frequency Range

47 ~ 53 Hz or 57 ~ 63 Hz

Power Factor

0.8

Current Crest Ratio

3:1

Voltage Distortion

Liner Load

3% THD

Non-Liner Load

6% THD

4% THD
7% THD

Waveform

Pure Sinewave

EFFICIENCY
AC Mode

Up to 88%

BATTERY
Type
Standard Model

Valve regulated Lead Acid battery (Maintenance free batteries)

Capacity

9AH

Recharge Time (Typical)


Charging Current

Long-Run Model

10AH

4 hours recover to 90% capacity


1.0 A (max)

Type

Depending on the application

Capacity

Depending on the application

Charging Current

4.0 A or 8.0 A (max)

OVERLOAD
100% < Load < 110%

Overload warning only (No shutdown)

100% < Load < 130%

30 sec

>130%

1.5 sec

INDICATORS
LCD Display

Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

PHYSICAL
Standard Model
Long-Run Model

Dimension (mm) D x W H
Net Weight (kgs)

17.2
397145220

Dimension (mm) D W H
Net Weight (kgs)

421 190 318

397 x 145 x 220


9.3
4.8

426 190 318

28

35.3

421190318

426190318

13.5

14.3

8.9

ENVIRONMENT
Operation Humidity
Ambient Temperature

<90% non-condensing
0C - +40C

Noise Level

45dBA @ 1 Meter

Regulations

Safety: EN62040-1-1; EMI62040-2; EN62040-3

MANAGEMENT
USB

Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC

L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.

Online UPS

Master Series (1P/1P) - Tower

Online Master Series 1KVA 10KVA


Master Series (1P/1P) - Tower is a true on-line double-conversion technology single-phase UPS system which provides
clean, high level quality power for critical devices such as small computer centers, servers, telecom applications and
industrial applications. It is available from 1KVA to 10KVA capacities with wide input voltage range and high accuracy
output voltage to protect against the outages, disturbances and spikes.
Master Series (1P/1P) - Tower is designed with a smart battery charger to optimize battery performance. High battery
charging current and battery extension assembly is available for long run applications. Internal bypass to assure
continuous power to critical devices during UPS maintenance and parallel redundancy which will back up the load in
the event of critical component failure is available for the 6KVA and 10KVA models. An optional of isolation transformer
can be attached to UPS unit without taking extra space.

True Double-Conversion Online UPS


Wide input voltage range (110~300VAC)
Input Power Factor correction 0.99
Output Power Factor 0.80
Generator compatible
LCD User Interface
RS-232 communication port or mini slot for USB/ RS-232/
AS400/ SNMP communication
Smart battery charger design for optimized battery
performance
Optional isolation transformer available

PRO801S/ L PRO802S/ L
PRO8015S/ L PRO803S/ L

PRO806S/ L
PRO810S/ L
Small Computer
Network

Local Area
Network (LAN)

Work-Stations

Service

Rear Panel
For 1KVA to 3KVA model

7
7
6

5
13

7
6

3
PRO801S/
PRO8015S

5
13

1
2

4
3

9
10
1
2

PRO801L/
PRO8015L

7
5

13

13

13

13
2 1

4
3

PRO802S/
PRO803S

10

2 1

4
3

PRO802L/
PRO803L

1. Programmable outlets: connect to noncritical loads


2. Output receptacles: connect to missioncritical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector
(EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. External battery connection (only available
for L model)
11. Output terminal
12. Output circuit breaker
13. Fan

Online UPS

For 6KVA to 10KVA model


1

6
8

6
8

14

9
10

16

12 13 15

PRO806S/
PRO810S

11

10

16

12 13 15

11

PRO806L/
PRO810L

1. RS-232 communication port


2. USB communication port
3. Emergency power off function connector (EPO
connector)
4. Share current port (only available for parallel
model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance bypass switch
10. Input circuit breaker
11. Input/Output terminal
12. Output terminal 1
13. Output terminal 2
14. External battery terminal (only available for
Long-run model)
15. Utility input terminal
16. Output IEC Socket

Battery Pack
For 1KVA to 3KVA model
Capacity
Battery Type
Battery Number

2KVA/ 3KVA

1KVA/ 1.5KVA
12V7AH

12V9AH

12V7AH

12V9AH

12V7AH

12V9AH

6 pcs

6 pcs

12 pcs

12 pcs

18 pcs

18 pcs

Dimension (DxWxH)

397145220

Weight (kg)

18

535190318

421190318
20

36

40

55

61

For 6KVA to 10KVA model


Capacity

6KVA/ 10KVA

Battery Type

12V7AH

12V9AH

12V7AH

12V9AH

12V7AH

12V9AH

Battery Number

20 pcs

20 pcs

40 pcs

40 pcs

60 pcs

60 pcs

Dimension (DxWxH)

592250576

Weight (kg)

64

592250576
72

109

125

830250576
166

190

Online UPS

Options

AS-400 Card for external alarm signal.


SNMP Card for data communication via network connection.
Output Isolation Transformer.
External PDU & Maintenance Bypass Switch. (suitable for UPS up to 3KVA only)

Full Specifications
MODELS

PRO801S/ L

PRO8015S/ L

PRO802S/ L

PRO803S/ L

PRO806S/ L

PRO810S/ L

Capacity

1000 VA/ 800 W

1500 VA/ 1200 W

2000 VA/ 1600 W

3000 VA/ 2400 W

6000 VA/ 4800 W

10000 VA/ 8000 W

INPUT
Nominal Voltage

208/ 220/ 230/ 240VAC

Voltage Range

110Vac <Vin<290Vac @ 50% LOAD / 175Vac <Vin<300Vac @ 100% LOAD

Nominal Frequency

50 or 60Hz

Frequency Range

40 ~ 70Hz
0.99

Power Factor
OUTPUT
Output Voltage

200/ 208/ 220/ 230/ 240VAC

Static Regulation

1%

Frequency

50Hz or 60Hz auto selection or selectable

Frequency Range

47 ~ 53Hz or 57 ~ 63Hz

Power Factor

0.8

Current Crest Ratio

3:1

Voltage Distortion

Linear Load

3% THD

4% THD

3% THD

Non-Linear Load

6% THD

7% THD

6% THD

Waveform

Pure Sinewave

EFFICIENCY
AC Mode

Up to 89%

BATTERY
Type
Standard Model

Capacity

Valve regulated Lead Acid battery (Maintenance free batteries)


7AH

Recharge Time (Typical)

9AH

Charging Current

9AH

9AH

7AH

9 hours recover to 90% capacity

1.0 A (max)
Depending on the application

Type
Long-Run Model

7AH

4 hours recover to 90% capacity

Depending on the application

Capacity
Charging Current

8.0 A (max)

4.0 A (max)

OVERLOAD
100% < Load < 110%

Overload warning only (No shutdown)

100% < Load < 130%

30 sec

>130%

2.0 sec

INDICATORS
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

LCD Display
PHYSICAL
Standard Model
Long-Run Model

Dimension (mm) D x W H
Net Weight (kgs)

14

26

397145220

Dimension (mm) D W H
Net Weight (kgs)

421 190 318

397 x 145 x 220


13
7

592 x 250 x 576


28

81

421190318
13

83
592 x 250 x 576

13

25

27

ENVIRONMENT
Operation Humidity

<90% non-condensing

Ambient Temperature
Noise Level
Regulations

0C - +40C
45dBA @ 1 Meter
55dBA @ 1 Meter 58dBA @ 1 Meter
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3

MANAGEMENT
USB/ RS-232

Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC

Derate to 60% of capacity in Frequency converter mode and to 80% when the output valtage is adjusted to 208VAC.
If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.

Online UPS

True double-conversion Online UPS

Higher Accuracy For Output Voltage

A true double conversion UPS will provide clean, high


level quality power to fully protect mission-critical
devices such as sensitive networks, small computer
centers, servers, telecom applications, as well as for
industrial applications.

With advanced control firmware, Master Series (1P/1P)


provides high accuracy within +/- 1% for output voltage.
It can be applied to precious test & IT equipment.

Output Power Factor 0.8


Compared to the online UPSs in the current market,
Master Series (1P/1P) provides better output power
factor up to 0.8. It offers higher performance and
efficiency for critical applications.

Wide Input Voltage Range (110 V -300 V)


Master Series (1P/1P) can still provide stable power to
connected devices under unstable power environments.

Programmable Power Management Outlets


With programmable power management
outlets, users can easily and indepenntly
control load segments. During power
failure, this feature enables users to extend
battery time to missioncritical devices by
shutting down the non-critical devices.
Programmable Outlets (P1)
- connect to non-critical devices

50/60 Hz Frequency Converter Mode


Lock output frequency at 50Hz or 60Hz to suit power
sensitive equipments.

ECO Mode Operation For Energy Saving


Offers efciency as high as 97% to cut energy usage &
cost. UPS power application via static bypass, timely
returning to online double conversion when the need
arises.

Emergency Power Off (EPO) Function


This feature can secure the personnel and equipment in
case of fires or other emergencies.

SNMP + USB + RS-232 Multiple


Communications For 1-3KVA Models
This feature allows either USB or RS-232
communication port to work with SNMP interface
simultaneously.

Smart Battery Charger Design To Optimize


Battery Performance
Master Series (1P/1P) 1-3KVA is equipped with 2-stage
charger design to guarantee battery discharge time.
Besides, it will adjust charging voltage according to
outside temperature. This features will extend the
useful service life of batteries.
Master Series (1P/1P) 6KVA and above models are
equipped with 3-stage extendable charger for optimized
battery performance. This feature extends the useful
service life of batteries and optimizes battery recharge
time. Besides, the extendable charger design can be
stacked in numbers for large-capacity battery
charging.

DSP Technology Applied For 6KVA And Above


Models
A DSP controller provides an improved
cost-effective solution with high performance.

and

Maintenance Bypass Available For 6KVA And


Above Models
Internal bypass assures continuous power to critical
devices during UPS maintenance.

Optional Hot Standby Mode And N+X


Parallel Redundancy Available For 6KVA And
Above Models
For genuinely redundant power protection, Master
Series (1P/1P) (6KVA and above models) can either be
used in parallel operation with up to 3 units or hot
standby mode. Slave UPS will back up the load in the
event of critical component failure. It increases power
safety and availability.

Adjustable Battery Numbers For 6KVA And


Above Models
Master Series (1P/1P) (6KVA and above models) can still
normal operate well with only 18 or 19 internal
batteries.

Built-in Isolation Transformer (Option)


With built-in isolation transformer, the UPS will offer
full isolation and complete common mode noise
rejection for connected precious equipment. It become
an ideal power source with 100% protection against
unexpected AC power problems.

Online UPS

Master Series (1P/1P) - Combo

Online Master Series 6KVA 10KVA


Master Series (1P/1P) - Combo is designed with a very small footprint size to solve the problem of limited space with
the support of 6kVA and 10kVA UPS system. Master Series (1P/1P) Combo used true on-line double-conversion
technology single-phase UPS system which provides clean, high level quality power for critical devices such as small
computer centres, servers & telecom applications.
Master Series (1P/1P) - Combo is available from 6KVA and 10KVA capacities with wide input voltage range and high
accuracy output voltage to protect against the outages, disturbances and spikes. Smart battery charger design to
optimize battery performance and high battery charging current and battery extension assembly is available for long
run applications.
True double-conversion on line UPS
DSP technology guarantees high performance
Wide input voltage range (110-300 VAC)
Active input power factor correction 0.99
Output power factor 0.8
50Hz/60Hz frequency converter mode
Standard backup UPS and long backup UPS in one integrated unit
Adjustable battery number from 16 blocks to 20 blocks
Adjustable charging current can be changed via LCD or
software (1A~6A)
Emergency power off function (EPO)
USB and RS-232 communications port and mini slot for
AS400/ SNMP communication.
Maintenance bypass available

PRO806CL/
PRO810CL

PRO806C/
PRO810C
Small Computer
Network

Local Area
Network (LAN)

Work-Stations

Service

Rear Panel
1
5

For 6KVA to 10KVA model

1. RS-232 communication port


2. USB communication port
3. Emergency power off function connector
(EPO connector)
4. Intelligent slot
5. Power stage fan
6. Maintenance bypass switch
7. Input circuit breaker
8. Input/Output terminal
9. External battery terminal (only available
for Long-run model)
10. Battery Compartment (only available for
Standard model)

5
7

6
8
4

1
5

3
10

5
7
6
8

PRO806CL/
PRO810CL

PRO806C/
PRO810C

10

Online UPS

Options
AS-400 Card for external alarm signal.
SNMP Card for data communication via network connection.
Output Isolation Transformer.

Full Specifications
MODELS

PRO806C/ CL

PRO810C/ CL

Capacity

6000 VA/ 4800 W

10000 VA/ 8000 W

INPUT
Nominal Voltage

208/ 220/ 230/ 240VAC

Voltage Range

110Vac <Vin<290Vac @ 50% LOAD / 176Vac <Vin<300Vac @ 100% LOAD

Nominal Frequency

50 or 60Hz

Frequency Range

46 ~ 64Hz
0.99

Power Factor
OUTPUT
Output Voltage

200/ 208/ 220/ 230/ 240VAC

Static Regulation

1%

Frequency

50Hz or 60Hz auto selection or selectable

Frequency Range

46 ~ 54Hz or 56 ~ 64Hz

Power Factor

0.8

Current Crest Ratio

3:1

Voltage Distortion

3% THD

Linear Load

5% THD

Non-Linear Load

Waveform

Pure Sinewave

EFFICIENCY
AC Mode

Up to 90%

BATTERY
Type
Standard Model

Valve regulated Lead Acid battery (Maintenance free batteries)


9AH

Capacity

9 hours recover to 90% capacity

Recharge Time (Typical)

1.0 A (max)

Charging Current
Long-Run Model

Type

Depending on the application

Capacity

Depending on the application

Charging Current

6.0 A (max)

OVERLOAD
10 mins

100% < Load < 110%


100% < Load < 130%

1 min

>130%

1.0 sec

INDICATORS
LCD Display

Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

PHYSICAL
Standard Model
Long-Run Model

360 x 192 x 688

Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)

440 x 192 x 688

60

75

360 x 192 x 318

440 x 192 x 318

21

23

ENVIRONMENT
Operation Humidity

<95% non-condensing

Ambient Temperature
Noise Level

0C - +40C
55dBA @ 1 Meter

Regulations

58dBA @ 1 Meter

Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3

MANAGEMENT
USB/ RS-232

Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC

L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.

11

Online UPS

Master Series (1P/1P) - 2-in-1 Rack/ Tower

Online Master Series 1KVA 10KVA


Master Series (1P/1P) 2-in-1 Rack/Tower is a true on-line double-conversion technology single-phase UPS system
with 2U universal-mount case. It can be easily installed as a floor-standing tower or with a 19-inch rackmount bracket.
The Master Series was designed with a high density output power factor of 0.9 to provide higher performance and
efficiency to critical applications such as sensitive networks, small computer centers, servers and telecom
applications. It is available in capacities from 1KVA to 10KVA with wide input voltage range and high accuracy output
voltage to protect against the outages, disturbances and spikes.
Master Series (1P/1P) - 2-in-1 Rack/Tower has been designed with a hot-swappable battery to ensure clean and
uninterruptible power to protected equipment during battery replacement. A high battery charging current and battery
extension assembly is available for long run applications. Parallel redundancy which will back up the load in the event
of critical component failure is available for the 6kVA and 10kVA models. Front panel digital display can be easily
adjusted through LCD setting to suit the installation format, whether it is left vertically standing or at wall mounted.
True Double-Conversion Online UPS
Rack or Tower design
Wide input voltage range (110~300VAC)
Input Power Factor correction 0.99
Output Power Factor 0.90
50/60Hz frequency converter mode
Hot-Swappable battery design
Emergency Power Off (EPO) function
ECO Mode Operation for energy saving
General Compatible
Charger capacity expansion to 8A for long-run models
SNMP+USB+RS232 multiple communications
Smart battery charger design for optimized battery performance
Selectable output voltage via LCD panel

PRO801RS to PRO803RS/
PRO801RL to PRO803RL

PRO806RS/ PRO810RS/
PRO806RL/ PRO810RL
Small Computer
Network

Local Area
Network (LAN)

Work-Stations

Service

19 Rack
Mount

Rear Panel
7
5

12

6 10

1
9

For 1KVA to 3KVA model

3
4

PRO801RS/PRO8015RS/PRO802RS
7
5

12

6 10

1
9

3
4

PRO801RL/PRO8015RL/PRO802RL
7
5

12

12

10

9 6

11

3
4

PRO803RS
5

12

12

7
10 9 6
8

1
2

11

1. Programmable outlets:Connect to non-critical loads


2. Output receptacles: Connect to mission-critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. Battery Compartment (only available for Standard model)
11. Input terminal
12. Fan

PRO803RL

12

Online UPS

For 6KVA to 10KVA model


1. Programmable outlets:Connect to non-critical loads
2. Output receptacles: Connect to mission-critical loads
3. AC input
4. Input circuit breaker
5. Network/Fax/Modem surge protection
6. Emergency power off function connector (EPO)
7. USB communication port
8. RS-232 communication port
9. SNMP intelligent slot
10. Battery Compartment (only available for Standard model)
11. Input terminal
12. Fan
13. Parallel port (only available for parallel model)
14. External maintenance by-pass switch connection
15. Output Terminal
16. Ground

13
9

6
7

14

12

10

11 16 15

PRO806RS/RL
PRO810RS/RL

Battery Pack
For 1KVA to 10KVA model
Capacity

1KVA

1.5KVA

Battery Type
Battery Number

3KVA

12V9AH
8 pcs

Dimension (DxWxH)
Weight (kg)

2KVA

6 pcs

8 pcs

48043888
31.1

29.1

31.1

6KVA

10KVA

12V7AH

12V9AH

12 pcs

20 pcs

60043888

580438133

43.3

57

63

Options
AS-400 Card for external alarm signal.
SNMP Card for data communication via network connection
MODBUS Card for communication
Universal Rackmount Slider for installation in rack cabinets
External PDU & Maintenance Bypass Switch (suitable for UPS up to 3KVA only)
Maintenance Bypass Switch [MBS] (for UPS 6 to 10KVA only)
External Automatic Transfer Switch (ATS)

MBS-rack-UK Schuko IEC NEMA

ATS-R

MBS - 6 to 10K

13

Online UPS

Full Specifications
PRO801RS/ RL

PRO8015RS/ RL

PRO802RS/ RL

PRO803RS/ RL

PRO806RS/ RL

PRO810RS/ RL

Apparent Power
Active Power (Standard Model)

1000 VA

1500 VA

2000 VA

3000 VA

6000 VA

10000 VA

900 VA

1350 VA

1800 VA

2700 VA

5400 VA

9000 VA

Active Power (Long-Run Model)

800 VA

1200 VA

1600 VA

2400 VA

4800 VA

8000 VA

MODELS
Capacity
INPUT
Nominal Voltage

208/ 220/ 230/ 240VAC

Voltage Range

120Vac <Vin<290Vac @ 50% LOAD / 170Vac <Vin<300Vac @ 100% LOAD

Nominal Frequency

50 or 60Hz

Frequency Range

40 ~ 70Hz
0.99

Power Factor
OUTPUT
Output Voltage

200/ 208/ 220/ 230/ 240VAC

Static Regulation

1%

Frequency

50Hz or 60Hz auto selection or selectable

Frequency Range

47 ~ 53Hz or 57 ~ 63Hz
0.9 @ Standard Model, 0.8 @ Long-Run Model

Power Factor
Current Crest Ratio
Voltage Distortion

5:1

3:1

5:1

3:1

2% THD

Linear Load
8% THD

Non-Linear Load

6% THD

Waveform

4% THD

Pure Sinewave

EFFICIENCY
AC Mode

Up to 90%

BATTERY
Type
Standard Model

Valve regulated Lead Acid battery (Maintenance free batteries)


9AH

Capacity
Recharge Time (Typical)
Charging Current

9 hours recover to 90% capacity

1.0 A (max)
Depending on the application

Type
Long-Run Model

9AH

7AH
4 hours recover to 90% capacity

Capacity

Depending on the application

Charging Current

4.0 A or 8.0 A (max)

4.0 A (max)

4.0 A (max)

OVERLOAD
100% < Load < 110%

Overload warning only (No shutdown)

10 mins

100% < Load < 130%

30 sec

1 min

>130%

2.0 sec

1 sec

INDICATORS
LCD Display

Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

PHYSICAL

Standard Model

Dimension (mm) D x W H

Net Weight (kgs)


Long-Run Model

Dimension (mm) D W H
Net Weight (kgs)

380x438x88 (2U)

12.9
380x438x88 (2U)
8.6

Battery Unit:
580x438x133 (3U)

Battery Unit:
580x438x133 (3U)

28

UPS Unit: 17
Battery Pack: 57

UPS Unit: 20
Battery Pack: 63

600x43x88(2U)

580x438x133 (3U)

668x438x133 (3U)

13.8

17

20

20.6

480x438x88 (2U)
10.7

UPS Unit:
688x438x133 (3U)

600x438x88 (2U)

480x438x88 (2U)

17.6

UPS Unit:
580x438x133 (3U)

11.3

ENVIRONMENT
Operation Humidity
Ambient Temperature
Noise Level
Regulations

<90% non-condensing
0C - +40C
50dBA @ 1 Meter
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3

MANAGEMENT
USB/ RS-232

Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC

L means Long-run model; S means Standard model.


Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.

14

Online UPS

True Double-conversion Online UPS

Output power factor 0.9

A true double conversion UPS will provide clean, high


level quality power to fully protect mission-critical
devices such as sensitive networks, small computer
centers, servers, telecom applications, as well as for
industrial applications.

Master (1P/1P) - 2-in-1 Rack/Tower Series is a highdensity UPS with output power factor 0.9 to provide
higher performance and efficiency to critical
applications.

User-friendly And Easy-shift LCD Display


The front panel digital display can be easily shifted
through LCD setting to suit the installation format, vertically stand or flat wall mount.

Programmable Power Management Outlets


With programmable power management outlets, users
can easily and independently control load segments.
During power failure, this feature enables users to
extend battery time to mission critical devices by
shutting down the non-critical devices.

Programmable Outlets (P1)


- connect to non-critical devices

Rack Display

Tower Display

Rack/ Tower Design


Master (1P/1P) - 2-in-1 Rack/Tower Series is designed
in true 2U universal-mount case. It can be easily
installed as floor-standing tower or in 19-inch rackmount bracket.

ECO And Advanced ECO Mode For Energy Saving


It allows UPS to operate in high efficiency up to 97%in
energy saving ECO mode and even up to 98%. In this
operation mode, load is supplied by the mains. In the
event of a mains failure, the inverter takes over the load
and provides supply continuity to the connected
systems.

Emergency Power Off Function (EPO)


This feature can secure the personnel and equipment in
case of fires or other emergencies.

Hot-swappable Battery Design


19 Rack-mounting

Floor-standing Tower

This design ensures clean and uninterruptible power to


protected equipment during battery replacement.

Higher Output Crest Radio Perfect For


Generator And Compressor
Compared to general online UPS, Master (1P/1P) 2-in-1 Rack/Tower Series provide higher current crest
ratio as 5:1. It can support not only precious IT
equipment, but also compressors and motor-type
devices.

Output Voltage Regulation < 1%


Master (1P/1P) - 2-in-1 Rack/ Tower Series offers better
output voltage regulation (+/-1%), which ensures higher
compatibility with even the most sensitive power
supplies.

Long-run Models Available


To provide longer backup time, we also offer long-run
models. If additional runtime is required, matching
external battery units is available.

15

Online UPS

Master Series (3P/1P) - Tower

Online Master Series 10KVA 20KVA


Master Series (3P/1P) - Tower is a true on-line double-conversion technology three-phase input / single-phase output
UPS system which ensure maximum protection and power quality for any type of load, especially for mission critical
applications such as data center systems, security systems, industrial processes and telecommunications. It is
available from 10KVA to 20KVA capacities with wide input voltage range and high accuracy output voltage to protect
against the outages, disturbances and spikes.
Master Series (3P/1P) - Tower with built in phase auto adapt function simplifies wire installation and single phase input
is acceptable. With IGBT technology, it provides generator compatible where handles frequency variations and other
power fluctuations that occur during generator operation. Internal bypass to assure continuous power to critical
devices during UPS maintenance and parallel redundancy which will back up the load in the event of critical component
failure is available. An optional of isolation transformer can be attached to UPS unit without taking extra space.
True Double-Conversion Online UPS
DSP technology guarantees high performance
Output Power Factor 0.80
Input Power Factor Correction 0.99
Wide input voltage range
Active power factor correction in all phases
50/60Hz frequency converter mode
Emergency Power Off (EPO) function
SNMP+USB+RS232 multiple communications
Adjustable battery numbers
Maintenance bypass available
Optional N+X parallel redundancy
Optional isolation transformer available

PRO83110S/L
PRO83115L/
PRO83120L

PRO83115S/
PRO83120S

Local Area Telecommunication


Network
Devices
(LAN)

Data
Centre

Electro-Medical
Device

Storage
PLCS

Emergency
Alarm
Devices

E-Business
(Server Farms,
ISP/ASP/POP)

Rear Panel
1 2 3

1 2 3 4

6
8

10

11

7
14

14

12

10

9
11

13

PRO83110S

12

13

PRO83110L

For 10KVA model


1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance by-pass switch
10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads
13. Input/Output terminal
14. External battery connector (only available for 10KL)

16

Online UPS

1 2 3

10
13

10

13

19 20

PRO83115L
PRO83120L

PRO83115S
PRO83120S

For 10K model

8
1 2 3

For 15KVA to 20KVA model


1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance by-pass switch
10. Input circuit breaker
11. Output circuit breaker for receptacles
12. Output receptacles: connect to mission-critical loads
13. Input/Output terminal
14. External battery connector (only available for 10KL)
15. Output terminal 1
16. Output terminal 2
17. External battery terminal (only available for Long-run model)
18. Utility input terminal
19. Non-isolated Neutral terminal (only available for parallel system)
20. Grounding terminal (only available for parallel system)

For 15K & 20K model

19 20
19 15 16

18

15 16 17

18

Options

AS-400 Card for external alarm signal.


SNMP Card for data communication via network connection
MODBUS Card for communication
Output Isolation Transformer

17

Online UPS

Full Specifications
MODELS

PRO83110S/ L

PRO83115S/ L

PRO83120S/ L

Capacity

10 KVA/ 8 KW

15 KVA/ 12 KW

20 KVA/ 16 KW

INPUT
Nominal Voltage

360/ 380/ 400/ 415VAC

Voltage Range

300Vac < Vin < 480Vac

Nominal Frequency

50 or 60Hz

Frequency Range

45 ~ 64Hz
0.99

Power Factor
OUTPUT
Output Voltage

200/ 208/ 220/ 230/ 240VAC

Static Regulation

1%
50Hz or 60Hz auto selection or selectable

Frequency
Frequency Range

46 ~ 54 Hz or 56 ~ 64 Hz

Power Factor

0.8

Current Crest Ratio

3:1

Voltage Distortion

2% THD

Liner Load
Non-Liner Load

6% THD

5% THD

Waveform

7% THD

Pure Sinewave

EFFICIENCY
AC Mode

Up to 89%

BATTERY
Type
Standard Model

Valve regulated Lead Acid battery (Maintenance free batteries)

Capacity

9AH

Recharge Time (Typical)


Charging Current

9 hours recover to 90% capacity


1.0 A (max)

Type
Long-Run Model

Capacity
Charging Current

2.0 A (max)
Depending on the application
Depending on the application

4.0 A (max)

8.0 A (max)

OVERLOAD
100% < Load < 110%

10 mins

100% < Load < 130%

1 min

>130%

1 sec

INDICATORS
LCD Display

Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

PHYSICAL
Standard Model
Long-Run Model

Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)

592 x 250 x 576

815 250 826

83

164

592 250 576

592 250 826

28

37

ENVIRONMENT
Protection

IP20

Operation Humidity

<95% non-condensing
0C - +40C

Ambient Temperature
Noise Level

58dBA @ 1 Meter

Regulations

60dBA @ 1 Meter
Safety: EN62040-1-1; EMI62040-2; EN62040-3

MANAGEMENT
USB

Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC

L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.

18

Online UPS

Master Series (3P/1P) - Rack Mount

Online Master Series 10kVA 20kVA


Master Series (3P/1P) - Rack mount is a true on-line double-conversion technology three-phase input / single-phase
outputUPS system with 3U to 6U universal-mount case. It is designed to ensure maximum protection and power quality
for any type of load, especially for mission critical applications such as data center systems, security systems and
telecommunications. It is available from 10kVA and 20kVA capacities with wide input voltage range and high accuracy
output voltage to protect against the outages, disturbances and spikes.
Master Series (3P/1P) - Rack mount with IGBT technology, it provides generator compatible where handles frequency
variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous
power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of
critical component failure is available.
True double-conversion
DSP technology guarantees high performance
Output Power Factor 0.8
Wide input voltage range
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
Eco mode operation for energy saving (ECO)
Emergency power off function (EPO)
Generator compatible
SNMP+USB+RS-232 multiple communications
Adjustable battery numbers
Optional N+X parallel redundancy

PRO83110RS/ RL

PRO83120RS/ RL

Local Area Telecommunication


Network
Devices
(LAN)

Data
Centre

19 Rack
Mount

Storage
PLCS

Emergency
Alarm
Devices

Rear Panel
4

5
11

4
7

1
6

2
3

9 12 10
PRO83110RS/ RL
5

1
6

12
10

2
3
4

For 10kVA to 20kVA model


1. RS-232 communication port
2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Parallel port (only available for parallel model)
5. Intelligent slot
6. Fan
7. External maintenance by-pass switch connection
8. Input circuit breaker
9. Input/Output terminal
10. Output terminal
11. Battery terminal
12. Input terminal

11
PRO83120RS/ RL

19

Online UPS

Options
AS-400 Card for external alarm signal.
SNMP Card for data communication via network connection
MODBUS Card for communication
Universal Rackmount Slider for installation in rack cabinets
External Maintenance Bypass Switch (10kVA only)

Full Specifications
MODELS

PRO83110RS/ RL

PRO83120RS/ RL

Capacity

10kVA/ 8kW

20kVA/ 16kW

INPUT
Nominal Voltage

360/ 380 /400/ 415VAC

Voltage Range

300Vac <Vin <480Vac

Nominal Frequency

50 or 60Hz

Frequency Range

46 ~ 64Hz
0.99

Power Factor
OUTPUT
Output Voltage

200/ 208/ 220/ 230/ 240VAC

Static Regulation

1%

Frequency

50Hz or 60Hz auto selection or selectable

Frequency Range

46 ~ 54Hz or 56 ~ 64Hz

Power Factor

0.8

Current Crest Ratio

3:1

Voltage Distortion

2% THD

Linear Load

5% THD

Non-Linear Load

Waveform

Pure Sinewave

EFFICIENCY
AC Mode

Up to 89%

BATTERY
Type
Standard Model

9AH

Recharge Time (Typical)


Charging Current

Long-Run Model

Valve regulated Lead Acid battery (Maintenance free batteries)

Capacity

9 hours recover to 90% capacity


1.0 A (max)

2.0A (max)

Type

Depending on the application

Capacity

Depending on the application

Charging Current

4.0 A (max)

OVERLOAD
10 mins

100% < Load < 110%


100% < Load < 130%

1 min

>130%

1.0 sec

INDICATORS
LCD Display

Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

PHYSICAL
Standard Model

Dimension (mm) D x W H
Net Weight (kgs)

Long-Run Model

Dimension (mm) D W H
Net Weight (kgs)

UPS Unit: 668 x 438 x 133 (3U)


Battery Pack: 580 x 438 x 133 (3U)

UPS Unit: 668 x 438 x 266 (6U)


BatteryPack: 580 x 438 x 133 (3U) x 2

UPS Unit: 23
Battery Pack: 63

UPS Unit: 23
Battery Pack: 63 x 2

668 x 438 x 133 (3U)

668 x 438 x 266 (6U)

23

38

ENVIRONMENT
Protection

IP20

Operation Humidity

<95% non-condensing

Ambient Temperature
Noise Level
Regulations

0C - +40C
58dBA @ 1 Meter

60dBA @ 1 Meter

Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3

MANAGEMENT
USB/ RS-232

Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC

L means Long-run model; S means Standard model.


Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.

20

Online UPS

Master Series (3P/3P) - Tower

Online Master Series 10kVA 20kVA


Master Series (3P/3P) - Tower is a true on-line double-conversion technology three-phase input/ three-phase output
UPS system, it is an ideal for protection and power quality for small server room, medical devices, industrial processes
and telecommunications facilities. It is available from 10kVA to 20kVA capacities with wide input voltage range and high
accuracy output voltage to protect against the outages, disturbances and spikes.
Master Series (3P/3P) - Tower with IGBT technology, it provides generator compatible where handles frequency
variations and other power fluctuations that occur during generator operation. Internal bypass to assure continuous
power to critical devices during UPS maintenance and parallel redundancy which will back up the load in the event of
critical component failure is available. An optional of isolation transformer can be attached to UPS unit without taking
extra space.
True double-conversion
DSP technology guarantees high performance
Wide input voltage range
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
Eco mode operation for energy saving (ECO)
Accepts dual power inputs
Emergency power off function (EPO)
Generator compatible
SNMP+USB+RS-232 multiple communications
Maintenance bypass available
Optional N+X parallel redundancy
Optional isolation transformer offers full isolation and
complete common mode noise

PRO83310S/L
PRO83320S/L
Local Area Telecommunication
Network
Devices
(LAN)

Rear Panel
1 2 3 4

8
9

7
7
11 10 14

13 16 15

Electro-Medical
Device

Storage
PLCS

Emergency
Alarm
Devices

E-Business
(Server Farms,
ISP/ASP/POP)

For 10kVA to 20kVA model

5
6

Data
Centre

12

PRO83310S/L
PRO83320S/L

1. RS-232 communication port


2. USB communication port
3. Emergency power off function connector (EPO connector)
4. Share current port (only available for parallel model)
5. Parallel port (only available for parallel model)
6. Intelligent slot
7. Charger fan
8. Power stage fan
9. Maintenance bypass switch
10. Bypass Input Circuit Breaker (Only available for dual input unit)
11. Input circuit breaker
12. Input/Output terminal
13. Output terminal
14. External battery terminal (only available for Long-run model)
15. Bypass input terminal (Only available for dual input)
16. Input terminal

21

Online UPS

Options
AS-400 Card for external alarm signal.
SNMP Card for data communication via network connection
MODBUS Card for communication
Output Isolation Transformer

Full Specifications
MODELS

PRO83310S/ L

PRO83320S/ L

Capacity

10kVA/ 8kW

20kVA/ 16kW

INPUT
Nominal Voltage

360/ 380 /400/ 415VAC

Voltage Range

300Vac <Vin <480Vac

Nominal Frequency

50 or 60Hz

Frequency Range

46 ~ 64Hz
0.99

Power Factor
OUTPUT
Output Voltage

360/ 380/ 400/ 415VAC

Static Regulation

1%

Frequency

50Hz or 60Hz auto selection or selectable

Frequency Range

46 ~ 54Hz or 56 ~ 64Hz

Power Factor

0.8

Current Crest Ratio

3:1

Voltage Distortion

2% THD

Linear Load

5% THD

Non-Linear Load

Waveform

Pure Sinewave

EFFICIENCY
AC Mode

Up to 89%

BATTERY
Type
Standard Model

Valve regulated Lead Acid battery (Maintenance free batteries)


9AH

Capacity
Recharge Time (Typical)

9 hours recover to 90% capacity


1.0 A (max)

Charging Current
Long-Run Model

2.0 A (max)

Type

Depending on the application

Capacity

Depending on the application

Charging Current

4.0 A (max)

OVERLOAD
100% < Load < 110%

10 mins

100% < Load < 130%

1 min

>130%

1 sec

INDICATORS
LCD Display

Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions

PHYSICAL
Standard Model
Long-Run Model

Dimension (mm) D x W H

815 x 250 x 826


109

Net Weight (kgs)

164

Dimension (mm) D W H

592 x 250 x 826

Net Weight (kgs)

38

40

ENVIRONMENT
Protection

IP20

Operation Humidity

<95% non-condensing
0C - +40C

Ambient Temperature
Noise Level

58dBA @ 1 Meter

Regulations

60dBA @ 1 Meter

Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3

MANAGEMENT
USB/ RS-232

Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC

L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Symbols: / meant for OR; meant for Multiply of.
Specification for Online UPS with Isolation Transformer to be provided upon request.
All specifications, designs and contents are subjected to changes without prior notice.

22

Online UPS

Power Series (3P/3P)

Online Power Series 15kVA 80kVA


Power Series (3P/3P) is a true on-line double-conversion technology three-phase input / three-phase output UPS
system, it is an ideal for protection and power quality where suitable for Data Center, Medical Equipments, and Call
Center. It is available from 15kVA to 80kVA capacities. Wide input voltage range and nearly equal to 1 high input power
factor and Harmonic Distortion to prevent over sizing cables, circuit breakers, and generator in lower total cost saving.
Power Series (3P/3P) design with front access concept easy for cable termination, trouble shooting, spares parts
replacement and preventative maintenances services. 5.7 LCD user friendly multilingual interface display monitoring
with all the information and alarms. Internal maintenance bypass to assure continuous power to critical devices during
UPS maintenance and parallel redundancy which will back up the load in the event of critical component failure is
available. An optional of isolation transformer can be attached to UPS unit without taking extra space.
Online double conversion technology with DSP control
Advanced control with Adaptive Feed Forward Cancellation
(AFC) technology for very low harmonic distortion
Very low input current distortion (THDi < 1%)
Input power factor 0.99 at 10%load
Output efciency up to 95%
Space-saving compact design
Front access makes maintenance and replacement easily
Control designed to withstand all kinds of loads
Variety of communication options available
Optional N+X parallel redundancy
Remaining backup time calculation
Optional isolation transformer

PRO73315S/SI PRO73330S/SI
PRO73320S/SI PRO73340S/SI
PRO73360S/SI
PRO73380S/SI

Local Area Telecommunication


Network
Devices
(LAN)

Data
Centre

Electro-Medical
Device

Storage
PLCS

Emergency
Alarm
Devices

E-Business
(Server Farms,
ISP/ASP/POP)

Front Panel (Internal)


For 15kVA to 80kVA model
1

10

10

3
10

6 7

5 6
5 6 7

PRO73315S/SI
PRO73320S/SI

PRO73330S/SI
PRO73340S/SI

PRO73360S/SI
PRO73380S/SI

1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel model)

23

Online UPS

Options
SNMP Card for data communication via network connection
MODBUS Card for communication
Output Isolation Transformer

Full Specifications
MODELS

PRO73315S/ SI

PRO73320S/ SI

PRO73330S/ SI

PRO73340S/ SI

PRO73360S/ SI

PRO73380S/ SI

Capacity

15KVA/ 12KW

20kVA/ 16KW

30kVA/ 24KW

40kVA/ 32KW

60kVA/ 48KW

80kVA/ 64KW

INPUT
Nominal Voltage

360/ 380 /400/ 415VAC

Voltage Range

300Vac <Vin <480Vac

Nominal Frequency

50 or 60Hz

Frequency Range

46 ~ 64Hz

Power Factor

1.0

THDi

<1.5%

OUTPUT
Output Voltage

360/ 380/ 400/ 415VAC

Static Regulation
Dynamic Stability

1%
5% in 10 ms

Frequency

50Hz or 60Hz auto selection or selectable

Frequency Stability

0.05%
0.8

Power Factor

3.2:1

Current Crest Ratio


Voltage Distortion
Phase
Displacement

Linear Load

0.5% THD

Non-Linear Load

1.5% THD
120 1%

Balanced Load

120 2%

Unbalanced Load

Waveform

Pure Sinewave

EFFICIENCY
Up to 94%

AC Mode
BATTERY
Type

Depending on the application

Capacity

Depending on the application


-18mV/C

Temperature Compensation
Charging Current

23 A (max)

47 A (max)

70 A (max)

OVERLOAD
100% < Load < 125%

10 mins

125% < Load < 135%

5 min

135% < Load < 150%

1 min

>150%

20 sec

PHYSICAL
Dimension (mm) D x W H
Net Weight (kgs)

700 x 450 x 1100


120

805 x 590 x 1320


190

200

300

ENVIRONMENT
Protection

IP20

Operation Humidity

<95% non-condensing
0C - +40C

Ambient Temperature
Noise Level

42 ~ 69dBA @ 1 Meter

Regulations

Safety: EN62040-1-1; EMI: EN62040-2; EN61000-1

MANAGEMENT
USB/ RS-232

Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC

If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specication for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specications, designs and contents are subjected to changes without prior notice.

24

Online UPS

Power
Series,
applied
with
state-of-the-art
PWM-transformerless technology, can easily adapt to
all kinds of diverse and complicated loads, such as the
non-linear systems (IT systems), strongly inductive or
capacitive loads, discharge lamps, and induction
motors. Ranging from 15K-80kVA, Power Series is
designed in terms of criteria of maximum efciency and
energy savings with highly compact format. It
makes installation and operation easily and
eco-environmentally. Each unit also has a wide range of
communication possibilities and a large variety of
options to ll out customers diverse inquiries. To
facilitate expansion easily, this unit can be set up in
parallel-redundant systems without any need for
additional hardware in the near future.

Input Power Factor 0.99 At 10% Load


Lower power losses would result in reduced
consumption, lower operation and maintenance costs.
INPUT POWER FACTOR
1,20
1,00
0,80

PFin

The Most Versatile Solution For Power


Protection

0,60
0,40
0,20
0,00

0%

25%

50%

75%

100%

LOAD

Output Efficiency Up To 95%


Online Double Conversion Technology With
DSP Control
Power Series is applied online double conversion
technology to effectively insulate against network
disturbances and enable higher load uptime. A Digital
Signal Processor (DSP) control provides an improved
solution with high performance.

Applied with DSP controller and the forth generation


IGBT transistors, the UPS can achieve high efciency of
up to 95%. It will save consumed energy due to lower
heat losses and make a longer lifespan for the critical
components of the unit.
SERIES TIPICAL EFFICIENCY
100%

Advanced Control With Adaptive Feed


Forward Cancellation (AFC) Technology For
Very Low Harmonic Distortion
By cancelling input current and output voltage
harmonics, the harmful effects of harmonic injection
into the power network is eliminated and it will enhance
load integrity.

EFFICIENCY

75%

50%

25%

0%

0%

25%

50%

75%

100%

LOAD

Space-saving Compact Design


Very Low Input Current Distortion (THDi < 1%)
AFC cells are used to achieve extremely low distortion
values. Low input current distortion rat THDi < 1%at full
load and also THDi < 5%with very small load (10%of
load). This will avoid the distortion of the electrical
network upstream of the UPS, resulting in savings from
the optimal use of the cables and protection devices in
the electrical network.

The use of transformerless technology allows a


considerable reduction of the weight and volume of the
units.

25

Online UPS

Front Access Makes


Replacement Easily

Maintenance

And

An important consideration
has been given to allow
generous access to the units
electronic cards and power
components. All the boards
are accessible by front panel
for easily maintenance and
replacement.

Variety Of
Available

Communications

And

Option

The UPS has provided the following


communication selections:
Relay interface
RS-232/485 port
1SNMP slot
Modbus RTU / SEC protocol
2connectors for parallel connection

standard

Over 60% Materials Recyclable


The UPS uses more than 60%recyclable
materials for being more respectful of
the environment.

Highly Flexibility In Single Phase/ Threephase Set-UPS


The UPS is a unit with high exibility in adapting inputs
and outputs, and may easily be set up depending on the
requirements of the facility.
Three-phase input / Three-phase output (III/III)
Three-phase input / Single phase output (III/I)
Single phase input / Single phase output (I/I)
Single phase input / Three-phase output (I/III)

Remaining Backup Time Calculation


By using powerful algorithms, an estimated remaining
backup time can be calculated and help users for
further arrangement in the event of a prolonged power
outage.

Control Designed To Withstand All Kinds Of


Loads
In Power Series, the control is designed to be able to
withstand all kinds of loads: resistive, capacitive,
non-linear, discharge lamps, induction motors, speed
drivers, etc. It makes the UPS tremendously versatile
and exible in supplying power to different types of
electronics. To make it simple to adapt the UPS for
different environment, there are a large number off
parameters that can be programmed locally or
remotely.

N+1 Redundancy
Power Series UPS are thought and designed for its
connection in parallel up to 4 units. Redundant systems
are being load shared among at same percentage. So,
the fault of one will make that the damaged UPS is out of
the system and rest will be able to supply the load with
all guarantee. It increase the reliability and assures an
AC power supply of quality to critical loads.

26

Line Interactive UPS

PRO Series

Line Interactive Series 650VA 1000VA


PRO Series is a line-interactive technology single-phase input / single-phase output UPS system, it is an ideal for
protection in small and economic package and provide clean and stable power for any home or small ofce application.
Wide input voltage range feature of 2 boosts, 1 buck, where continuous supply output voltage to more acceptable levels
at input undervoltage brownouts and overvoltages surges. To consider that facilitate and can be used under various
circumstances, PROLiNK line-interactive UPS have adopted the universal socket outlet.

PRO700V/VU

Built-in super smart charger, shorten 50% of charging time


Excellent microprocessor control guarantees high reliability
Boost and buck AVR for voltage stabilization
Auto restart while AC is recovering
Simulated sine wave
Off-mode charging
Cold start function
Optional USB/RS-232 communication port and RJ-11/RJ-45
protection
Offering LED and LCD panels for selections

PRO850VU/SU

PC

Printer

Work-Stations

PRO1200SV/SVU

Rear Panel
For 650VA to 1000VA model
1.
2.
3.
4.
5.

AC Input
Backup Output
Bypass Output (without battery back up)
USB Port (Only available in VU and SVU series)
RJ11

4
4
4

5
1

1
2

3
2

2
2
PRO700V/ VU

PRO850VU

2
PRO850SU

PRO1200SV/ SVU

27

Line Interactive UPS

Full Specifications
MODELS
Capacity

PRO700V/ VU

PRO850VU/ SU

PRO1200SV/ SVU

VA

650

850

1200

Watt

360

480

600

INPUT
Nominal Voltage

220/ 230/ 240VAC

Voltage Range

25%

Nominal Frequency

50 or 60Hz (Auto Sensing)

OUTPUT
Output Voltage Regulation (Battery Mode)

10%

Frequency
Transfer Time (Typical)

50Hz or 60Hz 1Hz


2 - 8ms

2 - 6ms, 10ms (max)


Simulated Sinewave

Waveform
BATTERY
Number of Battery

1 x 12V8.2AH

Recharge Time (Typical)

1 x 12V10AH

1 x 12V7AH

4 - 6 hours recover to 80% capacity

PROTECTION
Full Protection

Short Circuit, Overload, Discharge and Overcharge Protection

INDICATION
AC Mode Green Lighting
Battery Mode Yellow Lighting
LED Display

Charging Mode Green Flashing every 2 second


Overload Red Flashing every 0.5 second
Fault Red Lighting

ALARM
Battery Mode Sounding every 10 seconds
Low Battery Sounding every second
Overload Sounding every 0.5 second

Sounding

Battery Replacement Alarm Sounding every 2 seconds


Fault Continuously Sounding
PHYSICAL
287 x 100 x 142

Dimension (mm) D x W H
Net Weight (kgs)

4.25

350 x 146 x 160


4.9

ENVIRONMENT
Humidity
Noise Level

0-90% relative Humidity, 0C - +40C


Less than 40dBA

MANAGEMENT
USB/ RS-232

Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC

All specications, designs and contents are subjected to changes without prior notice.

28

Inverter UPS

IPS Series

Inverter Series
IPS Series is a compact design of inverter system which converts DC power to AC power with high efciency conversion.
The system is an economic ideal for provide clean and stable power for any home or small ofce application such as
TVs, stereos, desktop or laptop computers and other. With built-in high dc charger current, it is suitable to charge up
to 100Ah battery. To consider that facilitate and can be used under various circumstances, PROLiNK IPS series have
design with a very compact size for locate and storage as well as adopted the universal socket outlet for capacity up to
2000VA.
Super efcient DC to AC conversion, minimizing charging
losses.
High frequency technology, provides critical overload
protection.
User selectable for accepting wider input voltage.
Full automatic start operation and silent operation.
Compact size for convenient use and storage.
Small scale and cost effective inverter for home appliances
and ofce equipment.
Eco-friendly and non-polluting (green device).

IPS500/
IPS1000/ IPS2000
IPS5000

IPS3000

Rear Panel
For 500VA to 2000VA model
5
1

IPS500/ IPS1000/ IPS2000

1.
2.
3.
4.
5.

Battery 12V, 24V, 48V, 96V


Input Protector
Input Socket
Output Socket
Narrow/ Wide Selector

For 3000VA to 5000VA model


1.
2.
3.
4.

2
3

4
1

Battery Terminal
Input Protector
Input Socket
Output Socket

IPS3000

4
1
IPS5000

29

Inverter UPS

Full Specifications
MODELS
Capacity

IPS500

IPS1000

IPS2000

IPS3000

IPS5000

VA

500

1000

2000

3000

5000

Watt

300

600

1200

2500

4200

INPUT
Nominal Voltage
Voltage Range

220/ 230/ 240VAC


Narrow Range

170 - 280VAC

Wide Range

90 - 280VAC

OUTPUT
Nominal Voltage

230VAC

Output Voltage Regulation (Battery Mode)


Frequency

+10%/ -18%
50Hz or 60Hz

Frequency Regulation (Battery Mode)

0.1Hz

Transfer Time

10 - 20ms Typical, 40ms (max)

Waveform

Modied Sinewave

BATTERY
Charging Current

8Amp

10Amp

20Amp

12V
15V

DC Voltage
Overcharge Protec

24V
30V

48V
60V

INDICATION
AC Mode - Green
Battery Mode - Yellow
N/A

Fault - Red
Charging Mode - Green Flashing

LED Display

Overload- Red Flashing


AC Mode, Inverter Mode,
Charger Mode, Load Level, Fault

N/A

LCD Display
Alarm

Overload - Sounding every 0.5 secound


Low Battery - Sounding every 2 secounds
Fault - Countinuously sounding

Sounding

Overload - Sounding every 0.5 secound


Low Battery - Sounding every 2 secounds
High DC Voltage - Continuously sounding
Fan Fault - Sounding 2 time every secound

EFFICIENCY
AC to AC

>95%

DC to AC

>80%

PHYSICAL
Dimension (mm) D x W H
Net Weight (kgs)

2.0

224 x 255 x 80
2.3

2.5

268 x 330 x 76
4.9

407 x 350 x 110


9.0

ENVIRONMENT
Humidity
Noise Level

0~95% Relative Humidity. 0~40C


Less than 50dBA

Less than 60dBA

Note:
Product specications are subject to change without prior notice.
Indications:
P represents 24VDC; R represents 48VDC; L represents 96VDC

30

Solar

PROLiNK DC UPS

PDC Series - DC UPS


PROLiNK DC Series is a compact design of DC UPS system which converts AC power to DC power with dynamic voltage
regulator; the UPS can ensure stable DC power to connected load as utility. This UPS system is an economic ideal for
communication devices such as switch, hub, router and modem.The built-in DC start function enables the UPS to be
started up without supply of AC power. To consider that facilitate and can be used under various circumstances,
PROLiNK DC series has design with a very compact size for locate and storage.

PDC50

Dual DC Outputs
Microprocessor controlled guarantees high reliability
Compact size for standing and mounting exibility
Supports solar powered devices and communication applications
Auto restart while AC is recovering
Off-mode charging
Overload protection and short circuit protection

Full Specifications
MODELS

PDC50

Capacity

50W

INPUT
Nominal Voltage
Voltage Range
Frenquency

220VAC
160 - 280VAC
50 or 60Hz

OUTPUT
Nominal Voltage
Output Voltage Regulation
Transfer Time

12VDC
10V ~ 13.7V
0ms

EFFICIENCY
AC Mode
Battery Mode

>75% at Nominal Voltage (Battery Fully Charged)


>95% at Full Load

BATTERY
Battery Type
Charging Voltage
Charging Current
Typical Recharge Time

12V9AH x 1
13.7V 0.25V
2.8A or 2.3A at Nominal Voltage without Load
4 ~ 6 hours recover to 90% capacity

INDICATION
AC Mode

Green Lighting

Battery Mode

Yellow Lighting

Low Battery

Yellow Flashing

Fault
PROTECTION
Full Protection

Red Lighting
Short Circuit and Overload Protection

PHYSICAL
Dimension (mm) D x W H @ Vertically Stand
Net Weight (kgs)

228 x 82.5 x 207


3

ENVIRONMENT
Humidity
Temperature

0 ~ 90%
0C ~ 40C

All specications, designs and contents are subjected to changes without prior notice

31

Solar

PROLiNK Solar System

PCC Series
PCC Series is a combination of MPPT technology and DSP controller system, it will convert best voltage to charge battery
based on varied temperature. Compared to traditional solar charger controller, it allows your solar panels to operate at their
optimum power output voltage, providing higher efciency up to 97.7% with lower power loss.
PCC Series with inverter, solar panel, and external battery packs; it will become a standalone solar power system to generate
green power for your home application. PCC Series will convert solar power to charge external batteries, and then provide
power to home appliances via inverter. Its compatible to 4 different battery types, sealed lead acid, vented, gel and NiCd.

PCC300

PCC600

Intelligent Maximum Power Point Tracking technology


Built-in DSP controller with high performance
Automatic battery voltage detection
Three-stage charging optimizes battery performance
Auto load-detection
Multifunction LCD displays detailed information
Reverse polarity protection of solar panel and battery
Overcharge and overload protection
IP 43 protection for outdoor and harsh environment #1
IP 21 protection #2
Suitable for battery types of sealed lead acid, vented Gel, and NiCd
Standard RJ45 port or optional RS-485 communication port
for remote monitoring

PCC3000

Full Specifications
MODELS

PCC300

PCC600

PCC3000

Capacity

300W

600W

3000W

15 ~ 33V @ 12V

30 ~ 66V @ 24V

60 ~ 132VDC

50V

75V

150VDC

INPUT
MPPT Range @ Operating Voltage
Maximum PV Array Open Circuit Voltage
Maximum Current

18A

45A

OUTPUT
Nominal Battery Voltage

12V

Connected Battery Type


Maximum Charging Current

24V

48V

Sealed Lead Acid, Vented, Gel, MiCd Battery


25A

60A

Ripple Voltage

<1V

Maximum Efciency

97.8%

Stanby Power Consumption

98%

1W

Charging Method

2W
Three Stages: Bulk, Absorption & Floating

PROTECTIONS
Overload Protection

>110%: Audiable Alarm

INDICATION
LCD Panel

Yes
Yes
Yes

Overcharge Protection
Polarity Reversal Protection @ Solar Cell & Battery

LCD Panel indicating Solar Power, Output Power, Battery Voltage, Charging Current, and Fault Conditions

LED Display

Three indiators: Solar, Charging & Load Status

Three indiators: Solar, Battery &


Wiring Fault

PHYSICAL
Dimension (mm) D x W H
Net Weight (kgs)
Connector
Type of Mechanical Protection

135 x 170 x 57.5


0.92

220 x 170 x 57.5


1.85
Input or Output Terminal Block
IP43

180 x 210 x 80
1.28
IP21

ENVIRONMENT
Humidity
Operating Temperature
Storage Temperature
Altitude

0~90% Relative Humidity (non-condensing)


-20C to 55C
-40C to 75C
0 ~ 3000m

#1 Only applicable to Model with 50~300W. #2 Only applicable to Model with 3000W.
All specications, designs and contents are subjected to changes without prior notice.

32

Solar

PROLiNK Solar System

PSI Hybrid Series


PSI Hybride Series is a hybrid inverter which combines solar system, AC utility, and battery power source to supply continuous
power. It is suitable for the remote areas where the cost of utility is too high or emergency usage when utility is not stable. The
system will supply the load and feed power back to the utility grid when the PV energy output is available. When the PV energy
output is not sufcient for connected loads, the inverter will convert to the utility grid at the same time.

HYBRID 3K

Daytime or sunny day, works as an On Grid Inverter Night


time or rainy day, works as an Off Grid Inverter
Pure sine wave output
Multiple operations: Grid tie, Off grid, and grid-tie with
backup
Built-in MPPT solar charger
LCD display panel for comprehensive information
Multiple communication
Green substitution for generators

Full Specifications
MODELS

HYBRID 3K

Capacity

3000W

INPUT (DC)
Maximum DC Voltage

500VDC

MPP Voltage Range

250VDC ~ 450VDC

DC Nominal Voltage

360VDC

Maximum Input Current

13A

GRID/ UTILITY INPUT (AC)


Nominal AC Voltage/ Range
Maximum Input Current

208/ 220/ 230/ 240VAC / 175 ~ 280 VAC


20A

GRID OUTPUT (AC)


Nominal AC Voltage/ Range
AC Grid Frequency Range
Nominal Output Current
Power Factor
BATTERY MODE OUTPUT (AC)
Output Voltage

208/ 220/ 230/ 240VAC / 184 ~ 265VAC


47.5 ~ 50.2Hz
13A
>0.99
208/220/230/240 VAC

Output Frequency

50Hz

Output Waveform

Pure Sinewave

Efciency (DC to AC)

92%

BATTERY & CHARGE


Nominal DC Voltage
Maximum Charging Current
PHYSICAL
Dimension (mm) D x W H
Net Weight (kgs)

48VDC
25A
420 x 415 x 170
15.5

INTERFACE
Communication Port
Intelligent Slot
Wireless Connection

RS-485/ RS-232
Optional SNMP Card and Modbus Card available
Optional Zigbee Card and Wireless device available

ENVIRONMENT
Humidity
Operating Temperature
Altitude

0~90% Relative Humidity (non-condensing)


-25C to 60C
0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)

All specications, designs and contents are subjected to changes without prior notice.

33

Solar

PROLiNK Solar System

PSI On-Grid Series


PSI On-Grid Series can operate at their optimum power output voltage even under variety of weather conditions. Amnetz PV
inverters also allow a wide input voltage range to generate maximum 96% efciency. Besides, it also offers user-friendly
design and modulated electric design. Bundled with monitoring software, Amnetz PV inverters can monitor and calculate the
accurate saving energy.
1.5KW/2KW/3KW/5KW & 3-phase 10KW on-grid PV inverter
Advanced DSP control technology delivers accurate data
Smart MPPTs to enhance overall efciency
Modulized design for easy maintenance
Industrial-grade components used for robust operation
Data log up to 15 years
IP 65 protection for outdoor and harsh environment
Comprehensive LCD monitor for easy-reading
Free monitoring software

AMNETZ 1500
AMNETZ 2000
AMNETZ 3000

Full Specifications
MODELS

AMNETZ 1500

Capacity
Phase

1500W

AMNETZ 2000

AMNETZ 3000

AMNETZ 5000

AMNETZ 10K

5000W

10000W
3 Phase-In 3 Phase-Out
11000W

2000W
3000W
1 Phase-In 1 Phase-Out

INPUT (DC)
Maximum DC Power

1650W

2200W

3200W

5300W

Maximum DC Voltage

450VDC

500VDC

500VDC

500VDC

150 ~ 400VDC

200 ~ 450VDC

MPP Voltage Range


Nominal DC Voltage
Start-up Voltage/ Initial Feeding Voltage
Maximum Input Current/ Per String
OUTPUT (AC)
Nominal AC Voltage

900VDC
320 ~ 800VDC

360VDC

370VDC

600VDC

125/ 150VDC

116/ 150VDC

250/ 250VDC

11A
230VAC

230VAC

AC Voltage Range

10A

16A

17A

230VAC

230VAC

3/ N/ PE, 230/ 400VAC

21.7A

14.5A

-20% ~ +15%

AC Grid Frequency
Nominal Output Current

150 ~ 500VDC

50Hz / 60Hz
6.6A

8.7A

Power Factor

13A
>0.99

EFFICIENCY
Maximum Efciency

96.0%

96.5%

98.0%

PROTECTION
DC Reverse-Polarity Protection

Yes

Ground Fault Monitoring


Grid Monitoring

Yes
Yes

AC Short Circuit Protection

Yes

PHYSICAL
Dimension (mm) D x W H
Net Weight (kgs)

136.5 x 268.5 x 410

160 x 270 x 450

182 x 308 x 515

171.2 x 503.5 x 653.3

11.5

15

20

40

INTERFACE
Intelligent Slot
ENVIRONMENT
Humidity
Operating Temperature
Altitude

USB Card/ Optional: SNMP, RS-232, AS-400 and GPRS Cards


0 ~ 100% Relative Humidity (Non-condesing)
-25 ~ 60C

-25 ~ 55C

-25 ~ 60C

0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)

COMPLIANCE
Standard

CE, VDE 0126-1-1, IEC62109, ENEL Guide 2009, RD 1663, G83/ 1-1, AS3100/ AS4777

All specications, designs and contents are subjected to changes without prior notice.

34

Solar

PROLiNK Solar System

PSI Off-Grid Series


PSI Off-Grid Series is an off grid PV inverter which consists of three power sources such as PV modules, battery power, and
AC power sources. The AC power source could be supply by the generator or utility grid. Offnetz utilizes either sun energy or
self-generated AC source to convert stable power for house and commercial applications. Its perfect choice for long-term
power backup request in unstable power area and remote village.

OFFNETZ 2000
OFFNETZ 3000

DSP plus microprocessor redundant controllers.


Pure sine wave output
Isolation design between inverter and battery.
LCD display and recorded up to 15 years
Provides multiple communication ports for remote
monitoring with software.
Optional Modbus, SNMP, GPRS communication and AS400
dry contact.
Option: On-Grid

Full Specifications
MODELS

OFFNETZ 2000

OFFNETZ 3000

Capacity

2000W

3000W

PV INPUT (DC)
Maximum DC Voltage
Full Load MPP Voltage Range

500VDC

500VDC

170 ~ 450VDC

250 ~ 450VDC

Maximum Input Current


AC INPUT
Nominal AC Voltage

13A
100/ 110/ 120/ 127VAC

208/ 220/ 230/ 240VAC

Acceptable Voltage Range

85 ~ 145VAC

175 ~ 265VAC/ 175 ~ 280VAC

Acceptable Frequency Range

57.5 ~ 62.5Hz

47.5 ~ 52.2Hz

31A

20A

100/ 110/ 120/ 127VAC

208/ 220VAC or 230/ 240VAC

Maximum Input Current


BATTERY MODE OUTPUT (AC)
Output Voltage
Output Frequency

60Hz

Output Waveform
THDv

<3% @ Linear Load

Power Factor
Efciency (DC to AC)
Overload Capability
BATTERY & CHARGER
Nominal DC Voltage
Maximum Charging Current

50Hz
Pure Sinewave
>0.99

90%

92%
>110%: 5mins; >150%: 1min, 200%: Immediately
48VDC
25A

PHYSICAL
Dimension (mm) D x W H (Without Wheels)
Net Weight (kgs)

420 x 415 x 170


15.5

INTERFACE
Communication Port
Intelligent Slot

RS-232/ USB
Optional SNMP Card, ModBus Card, GPRS, And AS-400 Card Available

ENVIROMENT
Humidity
Operating Temperature
Altitude

0 ~ 90% Relative Humidity (non-condensing)


0 ~ 40C
0 ~ 1000m (Power derating 1% every 100m when altitude is over 1000m)

All specications, designs and contents are subjected to changes without prior notice.

35

Solar

PROLiNK Solar System

PSS Series
PSS Series is standalone solar power station consists of a solar charge controller, inverter, and a battery pack. This
solar power station provides clean power and cheaper operation cost to home and commercial application. To consider
that facilitate and can be used under various circumstances, Sonnensys is design for easy installation and limited space
requirement.
Easy installation: No technician need
Low cost
Unlimited and clean power source from sun
Expandable based on project need

SONNENSYS 850 SONNENSYS 150/


SONNENSYS 15PRO

Full Specifications
MODELS
Capacity

850VA/ 480W

INPUT (AC)
Voltage
Selectable
Voltage Range

SONNENSYS 1500

SONNENSYS 850
Volt-Amp/ Watt

SONNENSYS 1500 PRO


1500VA/ 1050W

120VAC or 230VAC

230VAC

For PCs

95 ~ 145VAC or 180 ~ 260VAC

180 ~ 260VAC

For Home Appliances

50 ~ 160VAC or 100 ~ 300VAC

100 ~ 300VAC

Ferquency Range

50/ 60Hz (Auto-Sensing)

OUTPUT (AC)
AC Voltage Regulation (Battery Mode)

100 ~ 120VAC 5% or 200 ~ 2300VAC 5%

200 ~ 230VAC 5%

Transfer Time

230VAC 5%

20ms Typical

Waveform (Battery Mode)

Simulated Sinawave

Pure Sinewave

31A

SOLAR CHARGER
MPPT Range @ Operating Voltage
Maximum PV Array Open Circuit Voltage
Maximum PV Array Power

20A

15 ~ 33VDC
50VDC

30 ~ 66V
75VDC

300W

600W
18A

Maximum Charging Current


BATTERY
Number & Type of Battery

1 x 12V100AH

2 x 12V100AH

Battery Voltage
Floating Charge Voltage

12VDC
13.7VDC 2%

24VDC
27.4VDC 2%

Maximum Charging Current

35A (10A AC Charger + 25A Solar Charger) or 45A (20A AC Charger + 25A Solar Charger)

PROTECTION
Full Protection

Overload & Short Circuit Protection

ALARM
Low Battery

Sounding every secound

Overload

Sounding every 0.5 secound

Battery Replacement

Sounding every 2 secound

Fault

Continuously Sounding

PHYSICAL
Dimension (mm) D x W x H (Without Wheels)
Net Weight (kgs)

53

OPERATING EBVIRONMENT
Humidity
Temperature

480 x 250 x 450

Operating
Storage

480 x 420 x 420


92

94

0 ~ 90% Relative Humidity (Non-condensing)


0 ~ 50C
-15 ~ 70C

All specications, designs and contents are subjected to changes without prior notice.

36

Software & Accessories

PROLiNK Online UPS Accessories

Automatic Transfer Switch


PROLiNK Automatic Transfer Switch (ATS) allow with two independent power input to supply power to the load from a primary
power source. In the even primary power source fails, it will automatically transfer the backup connection to the secondary
equipment without any interruption. The transfer time from one line to another is seamless to the connected equipment. The
Switch will transfer back to the primary input once it restored.
16A max. input current
Powered by two separately independent power sources
Dual power supply for redundancy
Provides seamless power switch for IT equipment
Preferred source selection on front panel
Highly reliablity 19" rack design (1U) to t into a diverse
working environment
Built-in USB and RS-232 communications

Full Specifications
MODELS

ATS

Current Rating

16A

INPUT
Input Voltage
Acceptable Input Voltage
Input Frequency

230VAC
207 ~ 253VAC
50Hz/ 60Hz

OUTPUT
Output Voltage
Maximum Output Current

230VAC
10A for IEC-C13 Outlets; 16A for IEC-C19 Outlets

CONNECTION
Input
Output
Communication
Transfer Time
PHYSICAL
Dimension (mm) D x W x H
Net Weight (kgs)

2xIEC-C20 Inlets
8xIEC-C13; 1xIEC-C19
USB/ RS-232
9 ~ 12ms (Typical)
310 x 430 x 44
3.65

ENVIRONMENT
Operating Temperature

20 ~ 95% Relative Humidity @ -5C ~ 45C (non-condensing)

All specications, designs and contents are subjected to changes without prior notice.

37

Software & Accessories

PROLiNK Online UPS Accessories

PDU & Maintenance Bypass Switch


PDU & Maintenance Bypass Switch is an external power distribution unit in conjunction with UPS systems or large-scale
voltage regulators. It allows to manually transferring the connected loads to utility power via a bypass switch, permitting
scheduled maintenance or UPS replacement without power interruption. Combined power distribution feature and the
master-controlled design, it provides maintenance bypass function and power saving within a compact mechanism.

Rack Type

Tower Type

16A for 208/220/230/240 VAC, 20A for 110/115/120/127 VAC


Provides continuous power to connected equipment during
UPS maintenance
Easy operation with simple rotary switch and indicators
Master-slave function for energy saving
Provides a large number of sockets for extended usage
Provides rack and tower designs to t into a diverse working
environment
Simple installation with plug-and-play socket type
Suitable for all UPSs up to 3KVA

IEC

UK

Schuko

NEMA

Full Specifications
MODELS

Rack Type

Current Rating

Tower Type

16A Max. for 208/ 220/ 230/ 240VAC; 20A Max. for 110/ 115/ 120/ 127VAC

Voltage Rating

208/ 220/ 230/ 240/VAC or 110/ 115/ 120/ 127VAC

Master/ Slave Function

Yes. When power consumption in Master Outlet is lower


than 20W (5W), it will shut off the power for slave outlets.

NA

CONNECTION
1 x IEC (16A) Connector & 1 x Customized Plug Cable

AC Power
Input

UPS Input
UPS Output
IEC

Output

1 x IEC (16A) Connector & 1 x Cable (16A ~ 10A IEC Cable for 1k/ 2k, 16A ~ 16A IEC cable for 3k)
5 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers)

Schuko

8 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers)

4 x Schuko 16A Sockets


4 x UK 13A Sockets

UK
5 x NEMA 20A Sockets

6 x NEMA 20A Sockets

IEC

80 x 438 x 50

180 x 160 x 50

Schuko
UK

80 x 438 x 60

180 x 200 x 50

NEMA

80 x 438 x 50

180 x 160 x 50

1.50

1.30

NEMA
PHYSICAL
Dimension (mm)
DxWxH
Net Weight (kgs)
ENVIRONMENT
Operating Temperature

20 ~ 95% Relative Humidity @ -0C ~ 40C (non-condensing)

All specications, designs and contents are subjected to changes without prior notice.

38

Software & Accessories

PROLiNK Online UPS Accessories

SNMP Card
Integrated with ViewPower software, SNMP Manager works as an enhanced communication solution for UPS monitoring and
management from anywhere with internet access. ViewPower software will leverage internet capability of SNMP manager to
remotely program or shut down UPSs.

(Integrated with ViewPower Pro software)

Allows control and monitoring of multiple UPSs through


RJ-45 network connection
Real-time dynamic graphs of UPS data (voltage, frequency,
load level, battery level)
Warning notications via audible alarm, broadcast, mobile
messenger, e-mail and SNMP traps
Historic data log stored in centralized PC database
Simple rmware upgrade with one click
Password security protection and remote access management
Supports optional environmental monitoring detector for
temperature, humidity and smoke

Modbus Card
The ModBus Card provides UPS and PV inverter systems with the functionality of communication with PCs through ModBus Protocol.
Implements ModBus RTU Protocol
Provides ModBus functions including read Holding
Registers and write Registers
Provides RS232 and RS485 interface

AS-400 Card
AS400 communication card provides contact closures for remote monitoring the UPS. To meet different application
requirement, the AS400 card is capable of selection the status of the dry-contact signal (normally close or normally open) by
setting jumper.
Capable of selection the status of the dry-contact signal by
setting jumper to meet different application requirements.
Suitable applications: IBM Server, Personal PC &
Workstations equipments, Auto-controlled industrial
equipment & communication applications

Rack Mount Slider


PROLiNK offers a ball bearing rack mounting slider kit for installing PROLiNK UPS system into 19 server rack enclosure. It
consists of a pair of heavy duty slides for the left and right side, with front and rear mounting brackets and mounting hard
ware.
Simple installation.
Suitable for PROLiNK Rack Mount Online UPS system.
Available at 700mm and 11100mm length slider for
difference type of cabinet.
All specications, designs and contents are subjected to changes without prior notice.

39

Software & Accessories

PROLiNK Online UPS Software

Viewpower UPS Management Software


ViewPower is advanced UPS management software. It allows remote monitor and manage from one to multiple UPSs in a
networked environment, either LAN or INTERNET. It is not only prevent data loss from power outage and safely shutdown
systems, but also store programming data and scheduled shutdown UPSs.
Allows control and monitoring of multiple UPSs via LAN and INTERNET
User-friendly power analysis graphs
Real-time dynamic graphs of UPS data
Safely OS shutdown and protection from data loss during power
failure
Warning notications via audible alarm, broadcast, mobile
messenger, and e-mail
Scheduled UPS on/off, battery test, programmable outlet control,
and audible alarm control
Password security protection and remote access management
Supports multiple OS and local languages

Solar Power Management Software


SolarPower Pro is a solar inverter monitoring software to monitor up to 247 devices via modbus interface. It also provides web
browser capability in a networked environment. The major functions of SolarPower Pro monitoring software include data log
for device, power generation statistics, alarm messages, fault messages, and parameter setting for devices.
Allows control and monitoring of multiple devices via LAN and
INTERNET
Automatic and real-time data acquisition of devices and secured
data log saving
Graphic display of device data for quick and easy reading
Warning notications or fault alarms via audible alarm, pop-up
screen, broadcast, mobile messenger, tray message and e-mail
Easy diagnosis from event statistics and amount calculation for
energy saving
Maximum data log up to 10 billion records
Supports online upgrade and manually upgrade
Supports multiple languages: English, Chinese, French, German,
Spanish, Russian, Portuguese, Ukrainian, Italian, Polish

All specications, designs and contents are subjected to changes without prior notice.

40

Appendix

PROLiNK UPS Battery Backup Configuration List

1. Professional Series (1P/1P) - Tower


POWER
RATING

BACK UP
TIME

BATTERY
GROUP

DC BUS
(VDC)

30 MINUTES

1 HOUR

2 HOUR

3 HOURS

4 HOURS

QUANTITY

QUANTITY

QUANTITY

QUANTITY

QUANTITY

PRO901L

2/24VDC

C1*1
12V18AH*4

C2*1
12V65AH*2

C3*1
12V100AH*2

C6*1
12V65AH*6

C8*1
12V65AH*8

PRO902L

4/48VDC

C2*1
12V18AH*8

C4*1
12V65AH*4

C4*1
12V100AH*4

C12*1
12V65AH*12

C16*1
12V65AH*16

PRO903L

6/72VDC

C3*1
12V18AH*12

C6*1
12V65AH*6

C6*1
12V100AH*6

C20*1
12V65AH*18

C24*1
12V65AH*24

PRO906L

8/96VDC

C8*1
12V26AH*16

C8*1
12V100AH*8

C24*1
12V65AH*24

C32*1
12V65AH*32

C20*2
12V65AH*40

REMARK

1. Without cable
from UPS
system to battery
bank.
2. All batteries
supply are
without battery
cables.

2. Master Series (1P/1P) - Tower


POWER
RATING

BACK UP
TIME

BATTERY
GROUP

DC BUS
(VDC)

30 MINUTES

1 HOUR

2 HOURS

3 HOURS

4 HOURS

QUANTITY

QUANTITY

QUANTITY

QUANTITY

QUANTITY

PRO801L

3/36VDC

C1*1
12V26AH*3

C3*1
12V26AH*6

C3*1
12V65AH*3

C6*1
12V65AH*6

C6*1
12V100AH*6

PRO8015L

3/36VDC

C2*1
12V18AH*6

C3*1
12V65AH*3

C3*1
12V100AH*3

C6*1
12V100AH*6

C12*1
12V65AH*12

PRO802L

6/72VDC

C3*1
12V26AH*6

C6*1
12V65AH*12

C6*1
12V65AH*6

C20*1
12V26AH*36

C12*1
12V100AH*12

PRO803L

6/72VDC

C3*1
12V18AH*12

C6*1
12V65AH*6

C6*1
12V100AH*6

C12*1
12V100AH*12

C20*1
12V65AH*18

PRO806L

20/240VDC

C12*1
12V26AH*20

C4*2
12V18AH*40

C20*1
12V26AH*40

C20*1
12V100AH*20

C20*2
12V65AH*40

PRO810L

20/240VDC

C4*2
12V18AH*40

C20*1
12V65AH*20

C20*1
12V100AH*20

C20*3
12V65AH*60

C20*2
12V100AH*40

REMARK

1. Without cable
from UPS
system to battery
bank.
2. All batteries
supply are
without battery
cables.

3. Master Series (1P/1P) - Combo


POWER
RATING

BACK UP
TIME

BATTERY
GROUP

DC BUS
(VDC)

30 MINUTES

1 HOUR

2 HOURS

3 HOURS

4 HOURS

QUANTITY

QUANTITY

QUANTITY

QUANTITY

QUANTITY

PRO806CL

20/240VDC

C12*1
12V26AH*20

C4*2
12V18AH*40

C20*1
12V26AH*40

C20*1
12V100AH*20

C20*2
12V65AH*40

PRO810CL

20/240VDC

C4*2
12V18AH*40

C20*1
12V65AH*20

C20*1
12V100AH*20

C20*3
12V65AH*60

C20*2
12V100AH*60

REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.

The battery backup conguration list above are applicable for isolation transformer version of UPS system.
All specications, designs and contents are subjected to changes without prior notice.

41

Appendix

PROLiNK UPS Battery Backup Configuration List

4. Master Series (1P/1P) - 2-in-1 Rack/ Tower


POWER
RATING

BACK UP
TIME

BATTERY
GROUP

DC BUS
(VDC)

30 MINUTES

1 HOUR

2 HOURS

3 HOURS

4 HOURS

QUANTITY

QUANTITY

QUANTITY

QUANTITY

QUANTITY

PRO801RL

2/24VDC

C1*1
12V18AH*4

C2*1
12V65AH*2

C3*1
12V100AH*2

C6*1
12V65AH*6

C8*1
12V65AH*8

PRO8015RL

3/36VDC

C2*1
12V18AH*6

C3*1
12V65AH*3

C3*1
12V100AH*3

C6*1
12V100AH*6

C12*1
12V65AH*12

PRO802RL

4/48VDC

C2*1
12V18AH*8

C4*1
12V65AH*4

C4*1
12V100AH*4

C12*1
12V65AH*12

C16*1
12V65AH*16

PRO803RL

6/72VDC

C3*1
12V18AH*12

C6*1
12V65AH*6

C6*1
12V100AH*6

C20*1
12V65AH*18

C24*1
12V65AH*24

PRO806RL

20/240VDC

C12*1
12V26AH*20

C20*1
12V26AH*40

C20*1
12V65AH*20

C20*2
12V65AH*40

C20*3
12V65AH*60

PRO810RL

20/240VDC

C20*1
12V26AH*40

C20*1
12V100AH*20

C20*2
12V65AH*40

C20*2
12V100AH*40

C20*4
12V65AH*80

REMARK

1. Without cable
from UPS
system to battery
bank.
2. All batteries
supply are
without battery
cables.

5. Master Series (3P/1P) - Tower


POWER
RATING

BACK UP
TIME

BATTERY
GROUP

DC BUS
(VDC)

30 MINUTES

1 HOUR

2 HOURS

3 HOURS

4 HOURS

QUANTITY

QUANTITY

QUANTITY

QUANTITY

QUANTITY

PRO83110L

20

C4*2
12V18AH*40

C20*1
12V65AH*20

C20*1
12V100AH*20

C20*3
12V65AH*60

C20*2
12V100AH*40

PRO83115L

20

C20*1
12V26AH*40

C20*1
12V100AH*20

C20*2
12V100AH*40

C20*4
12V65AH*80

C20*3
12V100AH*60

PRO83120L

20

C12*3
12V26AH*60

C20*2
12V65AH*40

C20*2
12V100AH*40

C20*6
12V65AH*120

C20*4
12V100AH*80

REMARK

1. Without cable from


UPS system to
battery bank.
2. All batteries supply
are without battery
cables.

6. Master Series (3P/1P) - Rack Mount


POWER
RATING

BACK UP
TIME

BATTERY
GROUP

DC BUS
(VDC)

30 MINUTES

1 HOUR

2 HOURS

3 HOURS

4 HOURS

QUANTITY

QUANTITY

QUANTITY

QUANTITY

QUANTITY

PRO83110RL

20

C4*2
12V18AH*40

C20*1
12V65AH*20

C20*1
12V100AH*20

C20*3
12V65AH*60

C20*2
12V100AH*40

PRO83120RL

20

C12*3
12V26AH*60

C20*2
12V65AH*40

C20*2
12V100AH*40

C20*6
12V65AH*120

C20*4
12V100AH*80

REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.

7. Master Series (3P/3P) - Tower


POWER
RATING

BACK UP
TIME

BATTERY
GROUP

DC BUS
(VDC)

30 MINUTES

1 HOUR

2 HOURS

3 HOURS

4 HOURS

QUANTITY

QUANTITY

QUANTITY

QUANTITY

QUANTITY

PRO83310L

20

C4*2
12V18AH*40

C20*1
12V65AH*20

C20*1
12V100AH*20

C20*3
12V65AH*60

C20*2
12V100AH*40

PRO83315L

20

C20*1
12V26AH*40

C20*1
12V100AH*20

C20*2
12V100AH*40

C20*4
12V65AH*80

C20*3
12V100AH*60

PRO83320L

20

C12*3
12V26AH*60

C20*2
12V65AH*40

C20*2
12V100AH*40

C20*6
12V65AH*120

C20*4
12V100AH*80

REMARK

1. Without cable from


UPS system to
battery bank.
2. All batteries supply
are without battery
cables.

The battery backup conguration list above are applicable for isolation transformer version of UPS system.
All specications, designs and contents are subjected to changes without prior notice.

42

Appendix

PROLiNK UPS Battery Backup Configuration List

8. Power Series (3P/3P)


POWER
RATING

BACK UP
TIME

BATTERY
GROUP

DC BUS
(VDC)

30 MINUTES

1 HOUR

2 HOURS

3 HOURS

4 HOURS

QUANTITY

QUANTITY

QUANTITY

QUANTITY

QUANTITY

PRO73315S

62

C16*1
12V18AH*62

C16*2
12V18AH*124

C32*2
12V26AH*124

C32*2
12V100AH*62

C32*4
12V65AH*124

PRO73320S

62

C32*1
12V26AH*62

C16*2
12V18AH*124

C32*2
12V65AH*62

C32*2
12V100AH*62

C32*4
12V65AH*124

PRO73330S

62

C16*2
12V18AH*124

C32*2
12V65AH*62

C32*2
12V100AH*62

C32*6
12V65AH*186

C32*4
12V100AH*124

PRO73340S

62

C32*2
12V26AH*124

C32*2
12V100AH*62

C32*4
12V65AH*124

C32*4
12V100AH*124

C32*8
12V65AH*248

PRO73360S

62

C32*2
12V65AH*62

C32*4
12V65AH*124

C32*4
12V100AH*124

C32*6
12V100AH*186

C32*8
12V100AH*248

PRO73380S

62

C32*2
12V100AH*62

C32*6
12V65AH*186

C32*8
12V65AH*248

C32*8
12V100AH*248

C32*10
12V100AH*310

REMARK

1. Without cable
from UPS
system to battery
bank.
2. All batteries
supply are
without battery
cables.

Battery Configurations
MODEL NO

CABINET
DIMENSION

CI
C2

CABINET WEIGHT

Available Battery Quantity


100AH

65AH

40AH

26AH

18AH

435*210*270
450*470*320

1
1

1
2

2
4

3
4

5
10

12V7AH or
12V9AH or 10Ah
/
/

C3

585*470*320

14

8kg

C4
C6

450*470*615
585*470*615

4
6

4
6

8
12

8
12

20
28

/
/

18kg
22kg

C8

780*470*615

16

16

36

25kg

C12
C16

780*470*900
780*470*1190

12
16

12
16

24
32

24
32

/
62

/
/

32kg
45kg

C20

950*470*1190

20

20

40

40

45kg

C24
C32

1150*470*1190
780*880*1190

24
32

24
32

/
62

/
62

/
/

/
/

75kg
95kg

REMARK

3.5kg
6kg

1. Option for DC
switch/protection
2. Option for battery
cable inter
connection.

G6

Completed assembled

G12

12

Completed assembled

G18
G60

18
60

Completed assembled
completed assembled

G8R

Completed assembled

G12R

12

Completed assembled

G20R

20

Completed assembled

The battery backup conguration list above are applicable for isolation transformer version of UPS system.
All specications, designs and contents are subjected to changes without prior notice.

43

Note

44

SINGAPORE
FIDA INTERNATIONAL (S) PTE LTD
Block 16 Kallang Place
#06-02, Singapore 339156
Tel: (65) 6357 0668
MALAYSIA
FIDA SYSTEMS (M) SDN BHD
Tel: (60) 3 8024 9151
INDONESIA
PROLiNK INDONESIA
Tel: (62) 21 3483 1777
Technical Support Hotline:
Singapore (65) 6357 0666
Malaysia (60) 3 8023 9151
Indonesia (62) 21 3482 1717
Operating Hours
Monday - Friday: 9.00am - 6.00pm
Closed on Saturday, Sunday & Public Holiday

Anda mungkin juga menyukai