UNINTERRUPTIBLE
POWER SUPPLY (UPS)
Protecting Your Data
CATALOGUE
Revision 2012
Table of Contents
Table of Contents
About Us - Company Profile
Online UPS
10
12
16
18
21
23
27
PRO Series
27
Inverter UPS
28
IPS Series
28
Solar UPS
31
31
PCC Series
32
33
34
35
PSS Series
36
37
Appendixz
41
Fida International (S) Pte Ltd has been a provider of technologically innovative and user-friendly products manufactured under the brand name PROLiNK since 1991. With more than two decades of professional experience in the
information communications sector, PROLiNK is now renowned as a specialist in its field, especially in area of Backup
UPS products.
Over the years, PROLiNK has built its presence through a strong foundation of technological leadership within the
South Asian, South-east Asian and Middle Eastern regions and is continuing to build its presence worldwide. With its
current network of sales offices in more than 20 countries, customers can be assured that PROLiNK is able to provide
the right solutions to meet the needs of both home and business users within each geographical location both
efficiently and effectively.
The companys quest for continuous improvement and quality assurance to its customers has earned us the ISO9001
quality certification since 1999. With its consistently strong commitment to quality, customers can be assured of they
are getting true value - superior quality products at affordable prices.
Our Mission
Accentuate The Best For The E-generation
PROLiNK aspires to accentuate the best for the e-generation. With technology becoming an essential aspect of
modern living, the e-generation concept has gradually become ingrained in our lives and digital literacy is becoming
more and more commonplace.
PROLiNK products are designed to make technology work for the e-generation. Created with the end-user in mind, our
products are crafted to enhance performance whether you are at work or play our products work harder, while you
work smarter to achieve your desired results with less effort and better efficiency.
Providing value to our consumers whether home or business users, remains a firm commitment of PROLiNK. With
its wide range of quality products, PROLiNK makes it easy for home users to find user-friendly yet affordable solutions
for their technological needs, while business users are assured of reliable and secure solutions for their network
infrastructure.
Our Vision
Ideas, Innovation and Information
PROLiNK aims to be the key driving force behind technological changes and improvements in both developing and
developed countries. With its strong focus on technology, our team sets high standards for itself in the areas of
innovation, change and improvement so as to provide the next generation of users with products that are suitable for
their technology advanced environments.
The small i in PROLiNK represents ideas, innovation and information three key pillars of growth that drive us
towards achieving excellence in our field of expertise and challenges us to think beyond our usual boundaries.
Core Values
Secured Information Management
With more than two decades of professional experience in providing backup power solutions to our customers, we are
able to support our customers with superior technological know-how and expertise, as well as advice on market
trends. At the same time, we are also fully committed to protecting the privacy of our customers and to manage
confidential information discreetly.
Innovative Design
Our products are carefully thought out to ensure that each item is designed to meet the needs of our customers. With
the teams solid experience in the UPS market, customers can be certain that our designs are innovative yet functional,
and suitable for each dynamic market that we have a presence in.
Range of UPS
The wide range of our products gives you an infinite range of solutions:
1. Online UPS
2. Line Interactive UPS
3. Inverter UPS
4. Solar UPS
Online UPS
PRO901S/ L
PRO902S/ L
PRO903S/ L
PRO906S/ L
Small Computer
Network
Local Area
Network (LAN)
Work-Stations
Service
Rear Panel
For 1KVA to 6KVA model
6
9
4
3
2
PRO901S/
PRO902S
5
4
6
6
4
3
2
PRO901L/
PRO902L
8
9
9
1
5
4
8
9
PRO903S/
PRO906S
PRO903L/
PRO906L
1. Output receptacles
2. AC input
3. Input circuit breaker
4. Network/Fax Modem Surge Protection
5. RS-232 communication port /
SNMP intelligent slot
6. External battery connection
(only available for L model)
7. Output terminal
8. Output circuit breaker
9. Fan
Online UPS
Options
Full Specifications
MODELS
PRO901S/ L
PRO902S/ L
PRO903S/ L
PRO906S/ L
Capacity
INPUT
Nominal Voltage
Voltage Range
110Vac < Vin < 290Vac @ 50% LOAD/ 168Vac < Vin < 300Vac @ 100% LOAD
Nominal Frequency
50 or 60Hz
Frequency Range
40 ~ 70Hz
0.98
Power Factor
OUTPUT
Output Voltage
Static Regulation
3%
1%
Frequency
Frequency Range
47 ~ 53 Hz or 57 ~ 63 Hz
Power Factor
0.8
3:1
Voltage Distortion
Liner Load
3% THD
Non-Liner Load
6% THD
4% THD
7% THD
Waveform
Pure Sinewave
EFFICIENCY
AC Mode
Up to 88%
BATTERY
Type
Standard Model
Capacity
9AH
Long-Run Model
10AH
Type
Capacity
Charging Current
OVERLOAD
100% < Load < 110%
30 sec
>130%
1.5 sec
INDICATORS
LCD Display
Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W H
Net Weight (kgs)
17.2
397145220
Dimension (mm) D W H
Net Weight (kgs)
28
35.3
421190318
426190318
13.5
14.3
8.9
ENVIRONMENT
Operation Humidity
Ambient Temperature
<90% non-condensing
0C - +40C
Noise Level
45dBA @ 1 Meter
Regulations
MANAGEMENT
USB
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
Online UPS
PRO801S/ L PRO802S/ L
PRO8015S/ L PRO803S/ L
PRO806S/ L
PRO810S/ L
Small Computer
Network
Local Area
Network (LAN)
Work-Stations
Service
Rear Panel
For 1KVA to 3KVA model
7
7
6
5
13
7
6
3
PRO801S/
PRO8015S
5
13
1
2
4
3
9
10
1
2
PRO801L/
PRO8015L
7
5
13
13
13
13
2 1
4
3
PRO802S/
PRO803S
10
2 1
4
3
PRO802L/
PRO803L
Online UPS
6
8
6
8
14
9
10
16
12 13 15
PRO806S/
PRO810S
11
10
16
12 13 15
11
PRO806L/
PRO810L
Battery Pack
For 1KVA to 3KVA model
Capacity
Battery Type
Battery Number
2KVA/ 3KVA
1KVA/ 1.5KVA
12V7AH
12V9AH
12V7AH
12V9AH
12V7AH
12V9AH
6 pcs
6 pcs
12 pcs
12 pcs
18 pcs
18 pcs
Dimension (DxWxH)
397145220
Weight (kg)
18
535190318
421190318
20
36
40
55
61
6KVA/ 10KVA
Battery Type
12V7AH
12V9AH
12V7AH
12V9AH
12V7AH
12V9AH
Battery Number
20 pcs
20 pcs
40 pcs
40 pcs
60 pcs
60 pcs
Dimension (DxWxH)
592250576
Weight (kg)
64
592250576
72
109
125
830250576
166
190
Online UPS
Options
Full Specifications
MODELS
PRO801S/ L
PRO8015S/ L
PRO802S/ L
PRO803S/ L
PRO806S/ L
PRO810S/ L
Capacity
INPUT
Nominal Voltage
Voltage Range
Nominal Frequency
50 or 60Hz
Frequency Range
40 ~ 70Hz
0.99
Power Factor
OUTPUT
Output Voltage
Static Regulation
1%
Frequency
Frequency Range
47 ~ 53Hz or 57 ~ 63Hz
Power Factor
0.8
3:1
Voltage Distortion
Linear Load
3% THD
4% THD
3% THD
Non-Linear Load
6% THD
7% THD
6% THD
Waveform
Pure Sinewave
EFFICIENCY
AC Mode
Up to 89%
BATTERY
Type
Standard Model
Capacity
9AH
Charging Current
9AH
9AH
7AH
1.0 A (max)
Depending on the application
Type
Long-Run Model
7AH
Capacity
Charging Current
8.0 A (max)
4.0 A (max)
OVERLOAD
100% < Load < 110%
30 sec
>130%
2.0 sec
INDICATORS
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
LCD Display
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W H
Net Weight (kgs)
14
26
397145220
Dimension (mm) D W H
Net Weight (kgs)
81
421190318
13
83
592 x 250 x 576
13
25
27
ENVIRONMENT
Operation Humidity
<90% non-condensing
Ambient Temperature
Noise Level
Regulations
0C - +40C
45dBA @ 1 Meter
55dBA @ 1 Meter 58dBA @ 1 Meter
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3
MANAGEMENT
USB/ RS-232
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC
Derate to 60% of capacity in Frequency converter mode and to 80% when the output valtage is adjusted to 208VAC.
If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
Online UPS
and
Online UPS
PRO806CL/
PRO810CL
PRO806C/
PRO810C
Small Computer
Network
Local Area
Network (LAN)
Work-Stations
Service
Rear Panel
1
5
5
7
6
8
4
1
5
3
10
5
7
6
8
PRO806CL/
PRO810CL
PRO806C/
PRO810C
10
Online UPS
Options
AS-400 Card for external alarm signal.
SNMP Card for data communication via network connection.
Output Isolation Transformer.
Full Specifications
MODELS
PRO806C/ CL
PRO810C/ CL
Capacity
INPUT
Nominal Voltage
Voltage Range
Nominal Frequency
50 or 60Hz
Frequency Range
46 ~ 64Hz
0.99
Power Factor
OUTPUT
Output Voltage
Static Regulation
1%
Frequency
Frequency Range
46 ~ 54Hz or 56 ~ 64Hz
Power Factor
0.8
3:1
Voltage Distortion
3% THD
Linear Load
5% THD
Non-Linear Load
Waveform
Pure Sinewave
EFFICIENCY
AC Mode
Up to 90%
BATTERY
Type
Standard Model
Capacity
1.0 A (max)
Charging Current
Long-Run Model
Type
Capacity
Charging Current
6.0 A (max)
OVERLOAD
10 mins
1 min
>130%
1.0 sec
INDICATORS
LCD Display
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
60
75
21
23
ENVIRONMENT
Operation Humidity
<95% non-condensing
Ambient Temperature
Noise Level
0C - +40C
55dBA @ 1 Meter
Regulations
58dBA @ 1 Meter
MANAGEMENT
USB/ RS-232
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
11
Online UPS
PRO801RS to PRO803RS/
PRO801RL to PRO803RL
PRO806RS/ PRO810RS/
PRO806RL/ PRO810RL
Small Computer
Network
Local Area
Network (LAN)
Work-Stations
Service
19 Rack
Mount
Rear Panel
7
5
12
6 10
1
9
3
4
PRO801RS/PRO8015RS/PRO802RS
7
5
12
6 10
1
9
3
4
PRO801RL/PRO8015RL/PRO802RL
7
5
12
12
10
9 6
11
3
4
PRO803RS
5
12
12
7
10 9 6
8
1
2
11
PRO803RL
12
Online UPS
13
9
6
7
14
12
10
11 16 15
PRO806RS/RL
PRO810RS/RL
Battery Pack
For 1KVA to 10KVA model
Capacity
1KVA
1.5KVA
Battery Type
Battery Number
3KVA
12V9AH
8 pcs
Dimension (DxWxH)
Weight (kg)
2KVA
6 pcs
8 pcs
48043888
31.1
29.1
31.1
6KVA
10KVA
12V7AH
12V9AH
12 pcs
20 pcs
60043888
580438133
43.3
57
63
Options
AS-400 Card for external alarm signal.
SNMP Card for data communication via network connection
MODBUS Card for communication
Universal Rackmount Slider for installation in rack cabinets
External PDU & Maintenance Bypass Switch (suitable for UPS up to 3KVA only)
Maintenance Bypass Switch [MBS] (for UPS 6 to 10KVA only)
External Automatic Transfer Switch (ATS)
ATS-R
MBS - 6 to 10K
13
Online UPS
Full Specifications
PRO801RS/ RL
PRO8015RS/ RL
PRO802RS/ RL
PRO803RS/ RL
PRO806RS/ RL
PRO810RS/ RL
Apparent Power
Active Power (Standard Model)
1000 VA
1500 VA
2000 VA
3000 VA
6000 VA
10000 VA
900 VA
1350 VA
1800 VA
2700 VA
5400 VA
9000 VA
800 VA
1200 VA
1600 VA
2400 VA
4800 VA
8000 VA
MODELS
Capacity
INPUT
Nominal Voltage
Voltage Range
Nominal Frequency
50 or 60Hz
Frequency Range
40 ~ 70Hz
0.99
Power Factor
OUTPUT
Output Voltage
Static Regulation
1%
Frequency
Frequency Range
47 ~ 53Hz or 57 ~ 63Hz
0.9 @ Standard Model, 0.8 @ Long-Run Model
Power Factor
Current Crest Ratio
Voltage Distortion
5:1
3:1
5:1
3:1
2% THD
Linear Load
8% THD
Non-Linear Load
6% THD
Waveform
4% THD
Pure Sinewave
EFFICIENCY
AC Mode
Up to 90%
BATTERY
Type
Standard Model
Capacity
Recharge Time (Typical)
Charging Current
1.0 A (max)
Depending on the application
Type
Long-Run Model
9AH
7AH
4 hours recover to 90% capacity
Capacity
Charging Current
4.0 A (max)
4.0 A (max)
OVERLOAD
100% < Load < 110%
10 mins
30 sec
1 min
>130%
2.0 sec
1 sec
INDICATORS
LCD Display
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
PHYSICAL
Standard Model
Dimension (mm) D x W H
Dimension (mm) D W H
Net Weight (kgs)
380x438x88 (2U)
12.9
380x438x88 (2U)
8.6
Battery Unit:
580x438x133 (3U)
Battery Unit:
580x438x133 (3U)
28
UPS Unit: 17
Battery Pack: 57
UPS Unit: 20
Battery Pack: 63
600x43x88(2U)
580x438x133 (3U)
668x438x133 (3U)
13.8
17
20
20.6
480x438x88 (2U)
10.7
UPS Unit:
688x438x133 (3U)
600x438x88 (2U)
480x438x88 (2U)
17.6
UPS Unit:
580x438x133 (3U)
11.3
ENVIRONMENT
Operation Humidity
Ambient Temperature
Noise Level
Regulations
<90% non-condensing
0C - +40C
50dBA @ 1 Meter
Safety: EN62040-1-1; EMI: EN62040-2; EN62040-3
MANAGEMENT
USB/ RS-232
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC
14
Online UPS
Master (1P/1P) - 2-in-1 Rack/Tower Series is a highdensity UPS with output power factor 0.9 to provide
higher performance and efficiency to critical
applications.
Rack Display
Tower Display
Floor-standing Tower
15
Online UPS
PRO83110S/L
PRO83115L/
PRO83120L
PRO83115S/
PRO83120S
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
Rear Panel
1 2 3
1 2 3 4
6
8
10
11
7
14
14
12
10
9
11
13
PRO83110S
12
13
PRO83110L
16
Online UPS
1 2 3
10
13
10
13
19 20
PRO83115L
PRO83120L
PRO83115S
PRO83120S
8
1 2 3
19 20
19 15 16
18
15 16 17
18
Options
17
Online UPS
Full Specifications
MODELS
PRO83110S/ L
PRO83115S/ L
PRO83120S/ L
Capacity
10 KVA/ 8 KW
15 KVA/ 12 KW
20 KVA/ 16 KW
INPUT
Nominal Voltage
Voltage Range
Nominal Frequency
50 or 60Hz
Frequency Range
45 ~ 64Hz
0.99
Power Factor
OUTPUT
Output Voltage
Static Regulation
1%
50Hz or 60Hz auto selection or selectable
Frequency
Frequency Range
46 ~ 54 Hz or 56 ~ 64 Hz
Power Factor
0.8
3:1
Voltage Distortion
2% THD
Liner Load
Non-Liner Load
6% THD
5% THD
Waveform
7% THD
Pure Sinewave
EFFICIENCY
AC Mode
Up to 89%
BATTERY
Type
Standard Model
Capacity
9AH
Type
Long-Run Model
Capacity
Charging Current
2.0 A (max)
Depending on the application
Depending on the application
4.0 A (max)
8.0 A (max)
OVERLOAD
100% < Load < 110%
10 mins
1 min
>130%
1 sec
INDICATORS
LCD Display
Input / Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W H
Net Weight (kgs)
Dimension (mm) D W H
Net Weight (kgs)
83
164
28
37
ENVIRONMENT
Protection
IP20
Operation Humidity
<95% non-condensing
0C - +40C
Ambient Temperature
Noise Level
58dBA @ 1 Meter
Regulations
60dBA @ 1 Meter
Safety: EN62040-1-1; EMI62040-2; EN62040-3
MANAGEMENT
USB
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specification for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specifications, designs and contents are subjected to changes without prior notice.
18
Online UPS
PRO83110RS/ RL
PRO83120RS/ RL
Data
Centre
19 Rack
Mount
Storage
PLCS
Emergency
Alarm
Devices
Rear Panel
4
5
11
4
7
1
6
2
3
9 12 10
PRO83110RS/ RL
5
1
6
12
10
2
3
4
11
PRO83120RS/ RL
19
Online UPS
Options
AS-400 Card for external alarm signal.
SNMP Card for data communication via network connection
MODBUS Card for communication
Universal Rackmount Slider for installation in rack cabinets
External Maintenance Bypass Switch (10kVA only)
Full Specifications
MODELS
PRO83110RS/ RL
PRO83120RS/ RL
Capacity
10kVA/ 8kW
20kVA/ 16kW
INPUT
Nominal Voltage
Voltage Range
Nominal Frequency
50 or 60Hz
Frequency Range
46 ~ 64Hz
0.99
Power Factor
OUTPUT
Output Voltage
Static Regulation
1%
Frequency
Frequency Range
46 ~ 54Hz or 56 ~ 64Hz
Power Factor
0.8
3:1
Voltage Distortion
2% THD
Linear Load
5% THD
Non-Linear Load
Waveform
Pure Sinewave
EFFICIENCY
AC Mode
Up to 89%
BATTERY
Type
Standard Model
9AH
Long-Run Model
Capacity
2.0A (max)
Type
Capacity
Charging Current
4.0 A (max)
OVERLOAD
10 mins
1 min
>130%
1.0 sec
INDICATORS
LCD Display
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
PHYSICAL
Standard Model
Dimension (mm) D x W H
Net Weight (kgs)
Long-Run Model
Dimension (mm) D W H
Net Weight (kgs)
UPS Unit: 23
Battery Pack: 63
UPS Unit: 23
Battery Pack: 63 x 2
23
38
ENVIRONMENT
Protection
IP20
Operation Humidity
<95% non-condensing
Ambient Temperature
Noise Level
Regulations
0C - +40C
58dBA @ 1 Meter
60dBA @ 1 Meter
MANAGEMENT
USB/ RS-232
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC
20
Online UPS
PRO83310S/L
PRO83320S/L
Local Area Telecommunication
Network
Devices
(LAN)
Rear Panel
1 2 3 4
8
9
7
7
11 10 14
13 16 15
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
5
6
Data
Centre
12
PRO83310S/L
PRO83320S/L
21
Online UPS
Options
AS-400 Card for external alarm signal.
SNMP Card for data communication via network connection
MODBUS Card for communication
Output Isolation Transformer
Full Specifications
MODELS
PRO83310S/ L
PRO83320S/ L
Capacity
10kVA/ 8kW
20kVA/ 16kW
INPUT
Nominal Voltage
Voltage Range
Nominal Frequency
50 or 60Hz
Frequency Range
46 ~ 64Hz
0.99
Power Factor
OUTPUT
Output Voltage
Static Regulation
1%
Frequency
Frequency Range
46 ~ 54Hz or 56 ~ 64Hz
Power Factor
0.8
3:1
Voltage Distortion
2% THD
Linear Load
5% THD
Non-Linear Load
Waveform
Pure Sinewave
EFFICIENCY
AC Mode
Up to 89%
BATTERY
Type
Standard Model
Capacity
Recharge Time (Typical)
Charging Current
Long-Run Model
2.0 A (max)
Type
Capacity
Charging Current
4.0 A (max)
OVERLOAD
100% < Load < 110%
10 mins
1 min
>130%
1 sec
INDICATORS
LCD Display
Input/ Output Voltage, Load Level, Batt Level, UPS Status, Fault Conditions
PHYSICAL
Standard Model
Long-Run Model
Dimension (mm) D x W H
164
Dimension (mm) D W H
38
40
ENVIRONMENT
Protection
IP20
Operation Humidity
<95% non-condensing
0C - +40C
Ambient Temperature
Noise Level
58dBA @ 1 Meter
Regulations
60dBA @ 1 Meter
MANAGEMENT
USB/ RS-232
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Symbols: / meant for OR; meant for Multiply of.
Specification for Online UPS with Isolation Transformer to be provided upon request.
All specifications, designs and contents are subjected to changes without prior notice.
22
Online UPS
PRO73315S/SI PRO73330S/SI
PRO73320S/SI PRO73340S/SI
PRO73360S/SI
PRO73380S/SI
Data
Centre
Electro-Medical
Device
Storage
PLCS
Emergency
Alarm
Devices
E-Business
(Server Farms,
ISP/ASP/POP)
10
10
3
10
6 7
5 6
5 6 7
PRO73315S/SI
PRO73320S/SI
PRO73330S/SI
PRO73340S/SI
PRO73360S/SI
PRO73380S/SI
1. Relay interface
2. Emergency Power Off (EPO)
3. RS-232 COM ports
4. Intelligent Slow
5. Input circuit breaker
6. Maintenance bypass switch
7. Output switch
8. Battery switch
9. System Terminal
10. Parallel port (only available for parallel model)
23
Online UPS
Options
SNMP Card for data communication via network connection
MODBUS Card for communication
Output Isolation Transformer
Full Specifications
MODELS
PRO73315S/ SI
PRO73320S/ SI
PRO73330S/ SI
PRO73340S/ SI
PRO73360S/ SI
PRO73380S/ SI
Capacity
15KVA/ 12KW
20kVA/ 16KW
30kVA/ 24KW
40kVA/ 32KW
60kVA/ 48KW
80kVA/ 64KW
INPUT
Nominal Voltage
Voltage Range
Nominal Frequency
50 or 60Hz
Frequency Range
46 ~ 64Hz
Power Factor
1.0
THDi
<1.5%
OUTPUT
Output Voltage
Static Regulation
Dynamic Stability
1%
5% in 10 ms
Frequency
Frequency Stability
0.05%
0.8
Power Factor
3.2:1
Linear Load
0.5% THD
Non-Linear Load
1.5% THD
120 1%
Balanced Load
120 2%
Unbalanced Load
Waveform
Pure Sinewave
EFFICIENCY
Up to 94%
AC Mode
BATTERY
Type
Capacity
Temperature Compensation
Charging Current
23 A (max)
47 A (max)
70 A (max)
OVERLOAD
100% < Load < 125%
10 mins
5 min
1 min
>150%
20 sec
PHYSICAL
Dimension (mm) D x W H
Net Weight (kgs)
200
300
ENVIRONMENT
Protection
IP20
Operation Humidity
<95% non-condensing
0C - +40C
Ambient Temperature
Noise Level
42 ~ 69dBA @ 1 Meter
Regulations
MANAGEMENT
USB/ RS-232
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC
If the UPS is installed or used in a place where the altitude is above than 1000m, the output power must be derated one percent per 100m.
L means Long-run model; S means Standard model; I means Isolation Transformer available (optional).
Specication for Online UPS with Isolation Transformer to be provided upon request.
Symbols: / meant for OR; meant for Multiply of.
All specications, designs and contents are subjected to changes without prior notice.
24
Online UPS
Power
Series,
applied
with
state-of-the-art
PWM-transformerless technology, can easily adapt to
all kinds of diverse and complicated loads, such as the
non-linear systems (IT systems), strongly inductive or
capacitive loads, discharge lamps, and induction
motors. Ranging from 15K-80kVA, Power Series is
designed in terms of criteria of maximum efciency and
energy savings with highly compact format. It
makes installation and operation easily and
eco-environmentally. Each unit also has a wide range of
communication possibilities and a large variety of
options to ll out customers diverse inquiries. To
facilitate expansion easily, this unit can be set up in
parallel-redundant systems without any need for
additional hardware in the near future.
PFin
0,60
0,40
0,20
0,00
0%
25%
50%
75%
100%
LOAD
EFFICIENCY
75%
50%
25%
0%
0%
25%
50%
75%
100%
LOAD
25
Online UPS
Maintenance
And
An important consideration
has been given to allow
generous access to the units
electronic cards and power
components. All the boards
are accessible by front panel
for easily maintenance and
replacement.
Variety Of
Available
Communications
And
Option
standard
N+1 Redundancy
Power Series UPS are thought and designed for its
connection in parallel up to 4 units. Redundant systems
are being load shared among at same percentage. So,
the fault of one will make that the damaged UPS is out of
the system and rest will be able to supply the load with
all guarantee. It increase the reliability and assures an
AC power supply of quality to critical loads.
26
PRO Series
PRO700V/VU
PRO850VU/SU
PC
Printer
Work-Stations
PRO1200SV/SVU
Rear Panel
For 650VA to 1000VA model
1.
2.
3.
4.
5.
AC Input
Backup Output
Bypass Output (without battery back up)
USB Port (Only available in VU and SVU series)
RJ11
4
4
4
5
1
1
2
3
2
2
2
PRO700V/ VU
PRO850VU
2
PRO850SU
PRO1200SV/ SVU
27
Full Specifications
MODELS
Capacity
PRO700V/ VU
PRO850VU/ SU
PRO1200SV/ SVU
VA
650
850
1200
Watt
360
480
600
INPUT
Nominal Voltage
Voltage Range
25%
Nominal Frequency
OUTPUT
Output Voltage Regulation (Battery Mode)
10%
Frequency
Transfer Time (Typical)
Waveform
BATTERY
Number of Battery
1 x 12V8.2AH
1 x 12V10AH
1 x 12V7AH
PROTECTION
Full Protection
INDICATION
AC Mode Green Lighting
Battery Mode Yellow Lighting
LED Display
ALARM
Battery Mode Sounding every 10 seconds
Low Battery Sounding every second
Overload Sounding every 0.5 second
Sounding
Dimension (mm) D x W H
Net Weight (kgs)
4.25
ENVIRONMENT
Humidity
Noise Level
MANAGEMENT
USB/ RS-232
Support Windows 2000/ 2003/ XP/ Vista/ 2008/ 7, Linux, Unix and MAC
All specications, designs and contents are subjected to changes without prior notice.
28
Inverter UPS
IPS Series
Inverter Series
IPS Series is a compact design of inverter system which converts DC power to AC power with high efciency conversion.
The system is an economic ideal for provide clean and stable power for any home or small ofce application such as
TVs, stereos, desktop or laptop computers and other. With built-in high dc charger current, it is suitable to charge up
to 100Ah battery. To consider that facilitate and can be used under various circumstances, PROLiNK IPS series have
design with a very compact size for locate and storage as well as adopted the universal socket outlet for capacity up to
2000VA.
Super efcient DC to AC conversion, minimizing charging
losses.
High frequency technology, provides critical overload
protection.
User selectable for accepting wider input voltage.
Full automatic start operation and silent operation.
Compact size for convenient use and storage.
Small scale and cost effective inverter for home appliances
and ofce equipment.
Eco-friendly and non-polluting (green device).
IPS500/
IPS1000/ IPS2000
IPS5000
IPS3000
Rear Panel
For 500VA to 2000VA model
5
1
1.
2.
3.
4.
5.
2
3
4
1
Battery Terminal
Input Protector
Input Socket
Output Socket
IPS3000
4
1
IPS5000
29
Inverter UPS
Full Specifications
MODELS
Capacity
IPS500
IPS1000
IPS2000
IPS3000
IPS5000
VA
500
1000
2000
3000
5000
Watt
300
600
1200
2500
4200
INPUT
Nominal Voltage
Voltage Range
170 - 280VAC
Wide Range
90 - 280VAC
OUTPUT
Nominal Voltage
230VAC
+10%/ -18%
50Hz or 60Hz
0.1Hz
Transfer Time
Waveform
Modied Sinewave
BATTERY
Charging Current
8Amp
10Amp
20Amp
12V
15V
DC Voltage
Overcharge Protec
24V
30V
48V
60V
INDICATION
AC Mode - Green
Battery Mode - Yellow
N/A
Fault - Red
Charging Mode - Green Flashing
LED Display
N/A
LCD Display
Alarm
Sounding
EFFICIENCY
AC to AC
>95%
DC to AC
>80%
PHYSICAL
Dimension (mm) D x W H
Net Weight (kgs)
2.0
224 x 255 x 80
2.3
2.5
268 x 330 x 76
4.9
ENVIRONMENT
Humidity
Noise Level
Note:
Product specications are subject to change without prior notice.
Indications:
P represents 24VDC; R represents 48VDC; L represents 96VDC
30
Solar
PROLiNK DC UPS
PDC50
Dual DC Outputs
Microprocessor controlled guarantees high reliability
Compact size for standing and mounting exibility
Supports solar powered devices and communication applications
Auto restart while AC is recovering
Off-mode charging
Overload protection and short circuit protection
Full Specifications
MODELS
PDC50
Capacity
50W
INPUT
Nominal Voltage
Voltage Range
Frenquency
220VAC
160 - 280VAC
50 or 60Hz
OUTPUT
Nominal Voltage
Output Voltage Regulation
Transfer Time
12VDC
10V ~ 13.7V
0ms
EFFICIENCY
AC Mode
Battery Mode
BATTERY
Battery Type
Charging Voltage
Charging Current
Typical Recharge Time
12V9AH x 1
13.7V 0.25V
2.8A or 2.3A at Nominal Voltage without Load
4 ~ 6 hours recover to 90% capacity
INDICATION
AC Mode
Green Lighting
Battery Mode
Yellow Lighting
Low Battery
Yellow Flashing
Fault
PROTECTION
Full Protection
Red Lighting
Short Circuit and Overload Protection
PHYSICAL
Dimension (mm) D x W H @ Vertically Stand
Net Weight (kgs)
ENVIRONMENT
Humidity
Temperature
0 ~ 90%
0C ~ 40C
All specications, designs and contents are subjected to changes without prior notice
31
Solar
PCC Series
PCC Series is a combination of MPPT technology and DSP controller system, it will convert best voltage to charge battery
based on varied temperature. Compared to traditional solar charger controller, it allows your solar panels to operate at their
optimum power output voltage, providing higher efciency up to 97.7% with lower power loss.
PCC Series with inverter, solar panel, and external battery packs; it will become a standalone solar power system to generate
green power for your home application. PCC Series will convert solar power to charge external batteries, and then provide
power to home appliances via inverter. Its compatible to 4 different battery types, sealed lead acid, vented, gel and NiCd.
PCC300
PCC600
PCC3000
Full Specifications
MODELS
PCC300
PCC600
PCC3000
Capacity
300W
600W
3000W
15 ~ 33V @ 12V
30 ~ 66V @ 24V
60 ~ 132VDC
50V
75V
150VDC
INPUT
MPPT Range @ Operating Voltage
Maximum PV Array Open Circuit Voltage
Maximum Current
18A
45A
OUTPUT
Nominal Battery Voltage
12V
24V
48V
60A
Ripple Voltage
<1V
Maximum Efciency
97.8%
98%
1W
Charging Method
2W
Three Stages: Bulk, Absorption & Floating
PROTECTIONS
Overload Protection
INDICATION
LCD Panel
Yes
Yes
Yes
Overcharge Protection
Polarity Reversal Protection @ Solar Cell & Battery
LCD Panel indicating Solar Power, Output Power, Battery Voltage, Charging Current, and Fault Conditions
LED Display
PHYSICAL
Dimension (mm) D x W H
Net Weight (kgs)
Connector
Type of Mechanical Protection
180 x 210 x 80
1.28
IP21
ENVIRONMENT
Humidity
Operating Temperature
Storage Temperature
Altitude
#1 Only applicable to Model with 50~300W. #2 Only applicable to Model with 3000W.
All specications, designs and contents are subjected to changes without prior notice.
32
Solar
HYBRID 3K
Full Specifications
MODELS
HYBRID 3K
Capacity
3000W
INPUT (DC)
Maximum DC Voltage
500VDC
250VDC ~ 450VDC
DC Nominal Voltage
360VDC
13A
Output Frequency
50Hz
Output Waveform
Pure Sinewave
92%
48VDC
25A
420 x 415 x 170
15.5
INTERFACE
Communication Port
Intelligent Slot
Wireless Connection
RS-485/ RS-232
Optional SNMP Card and Modbus Card available
Optional Zigbee Card and Wireless device available
ENVIRONMENT
Humidity
Operating Temperature
Altitude
All specications, designs and contents are subjected to changes without prior notice.
33
Solar
AMNETZ 1500
AMNETZ 2000
AMNETZ 3000
Full Specifications
MODELS
AMNETZ 1500
Capacity
Phase
1500W
AMNETZ 2000
AMNETZ 3000
AMNETZ 5000
AMNETZ 10K
5000W
10000W
3 Phase-In 3 Phase-Out
11000W
2000W
3000W
1 Phase-In 1 Phase-Out
INPUT (DC)
Maximum DC Power
1650W
2200W
3200W
5300W
Maximum DC Voltage
450VDC
500VDC
500VDC
500VDC
150 ~ 400VDC
200 ~ 450VDC
900VDC
320 ~ 800VDC
360VDC
370VDC
600VDC
125/ 150VDC
116/ 150VDC
250/ 250VDC
11A
230VAC
230VAC
AC Voltage Range
10A
16A
17A
230VAC
230VAC
21.7A
14.5A
-20% ~ +15%
AC Grid Frequency
Nominal Output Current
150 ~ 500VDC
50Hz / 60Hz
6.6A
8.7A
Power Factor
13A
>0.99
EFFICIENCY
Maximum Efciency
96.0%
96.5%
98.0%
PROTECTION
DC Reverse-Polarity Protection
Yes
Yes
Yes
Yes
PHYSICAL
Dimension (mm) D x W H
Net Weight (kgs)
11.5
15
20
40
INTERFACE
Intelligent Slot
ENVIRONMENT
Humidity
Operating Temperature
Altitude
-25 ~ 55C
-25 ~ 60C
COMPLIANCE
Standard
CE, VDE 0126-1-1, IEC62109, ENEL Guide 2009, RD 1663, G83/ 1-1, AS3100/ AS4777
All specications, designs and contents are subjected to changes without prior notice.
34
Solar
OFFNETZ 2000
OFFNETZ 3000
Full Specifications
MODELS
OFFNETZ 2000
OFFNETZ 3000
Capacity
2000W
3000W
PV INPUT (DC)
Maximum DC Voltage
Full Load MPP Voltage Range
500VDC
500VDC
170 ~ 450VDC
250 ~ 450VDC
13A
100/ 110/ 120/ 127VAC
85 ~ 145VAC
57.5 ~ 62.5Hz
47.5 ~ 52.2Hz
31A
20A
60Hz
Output Waveform
THDv
Power Factor
Efciency (DC to AC)
Overload Capability
BATTERY & CHARGER
Nominal DC Voltage
Maximum Charging Current
50Hz
Pure Sinewave
>0.99
90%
92%
>110%: 5mins; >150%: 1min, 200%: Immediately
48VDC
25A
PHYSICAL
Dimension (mm) D x W H (Without Wheels)
Net Weight (kgs)
INTERFACE
Communication Port
Intelligent Slot
RS-232/ USB
Optional SNMP Card, ModBus Card, GPRS, And AS-400 Card Available
ENVIROMENT
Humidity
Operating Temperature
Altitude
All specications, designs and contents are subjected to changes without prior notice.
35
Solar
PSS Series
PSS Series is standalone solar power station consists of a solar charge controller, inverter, and a battery pack. This
solar power station provides clean power and cheaper operation cost to home and commercial application. To consider
that facilitate and can be used under various circumstances, Sonnensys is design for easy installation and limited space
requirement.
Easy installation: No technician need
Low cost
Unlimited and clean power source from sun
Expandable based on project need
Full Specifications
MODELS
Capacity
850VA/ 480W
INPUT (AC)
Voltage
Selectable
Voltage Range
SONNENSYS 1500
SONNENSYS 850
Volt-Amp/ Watt
120VAC or 230VAC
230VAC
For PCs
180 ~ 260VAC
100 ~ 300VAC
Ferquency Range
OUTPUT (AC)
AC Voltage Regulation (Battery Mode)
200 ~ 230VAC 5%
Transfer Time
230VAC 5%
20ms Typical
Simulated Sinawave
Pure Sinewave
31A
SOLAR CHARGER
MPPT Range @ Operating Voltage
Maximum PV Array Open Circuit Voltage
Maximum PV Array Power
20A
15 ~ 33VDC
50VDC
30 ~ 66V
75VDC
300W
600W
18A
1 x 12V100AH
2 x 12V100AH
Battery Voltage
Floating Charge Voltage
12VDC
13.7VDC 2%
24VDC
27.4VDC 2%
35A (10A AC Charger + 25A Solar Charger) or 45A (20A AC Charger + 25A Solar Charger)
PROTECTION
Full Protection
ALARM
Low Battery
Overload
Battery Replacement
Fault
Continuously Sounding
PHYSICAL
Dimension (mm) D x W x H (Without Wheels)
Net Weight (kgs)
53
OPERATING EBVIRONMENT
Humidity
Temperature
Operating
Storage
94
All specications, designs and contents are subjected to changes without prior notice.
36
Full Specifications
MODELS
ATS
Current Rating
16A
INPUT
Input Voltage
Acceptable Input Voltage
Input Frequency
230VAC
207 ~ 253VAC
50Hz/ 60Hz
OUTPUT
Output Voltage
Maximum Output Current
230VAC
10A for IEC-C13 Outlets; 16A for IEC-C19 Outlets
CONNECTION
Input
Output
Communication
Transfer Time
PHYSICAL
Dimension (mm) D x W x H
Net Weight (kgs)
2xIEC-C20 Inlets
8xIEC-C13; 1xIEC-C19
USB/ RS-232
9 ~ 12ms (Typical)
310 x 430 x 44
3.65
ENVIRONMENT
Operating Temperature
All specications, designs and contents are subjected to changes without prior notice.
37
Rack Type
Tower Type
IEC
UK
Schuko
NEMA
Full Specifications
MODELS
Rack Type
Current Rating
Tower Type
16A Max. for 208/ 220/ 230/ 240VAC; 20A Max. for 110/ 115/ 120/ 127VAC
Voltage Rating
NA
CONNECTION
1 x IEC (16A) Connector & 1 x Customized Plug Cable
AC Power
Input
UPS Input
UPS Output
IEC
Output
1 x IEC (16A) Connector & 1 x Cable (16A ~ 10A IEC Cable for 1k/ 2k, 16A ~ 16A IEC cable for 3k)
5 x IEC 10A Socket + 1 x IEC 16A Socket (with 2 circuit breakers)
Schuko
UK
5 x NEMA 20A Sockets
IEC
80 x 438 x 50
180 x 160 x 50
Schuko
UK
80 x 438 x 60
180 x 200 x 50
NEMA
80 x 438 x 50
180 x 160 x 50
1.50
1.30
NEMA
PHYSICAL
Dimension (mm)
DxWxH
Net Weight (kgs)
ENVIRONMENT
Operating Temperature
All specications, designs and contents are subjected to changes without prior notice.
38
SNMP Card
Integrated with ViewPower software, SNMP Manager works as an enhanced communication solution for UPS monitoring and
management from anywhere with internet access. ViewPower software will leverage internet capability of SNMP manager to
remotely program or shut down UPSs.
Modbus Card
The ModBus Card provides UPS and PV inverter systems with the functionality of communication with PCs through ModBus Protocol.
Implements ModBus RTU Protocol
Provides ModBus functions including read Holding
Registers and write Registers
Provides RS232 and RS485 interface
AS-400 Card
AS400 communication card provides contact closures for remote monitoring the UPS. To meet different application
requirement, the AS400 card is capable of selection the status of the dry-contact signal (normally close or normally open) by
setting jumper.
Capable of selection the status of the dry-contact signal by
setting jumper to meet different application requirements.
Suitable applications: IBM Server, Personal PC &
Workstations equipments, Auto-controlled industrial
equipment & communication applications
39
All specications, designs and contents are subjected to changes without prior notice.
40
Appendix
BACK UP
TIME
BATTERY
GROUP
DC BUS
(VDC)
30 MINUTES
1 HOUR
2 HOUR
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO901L
2/24VDC
C1*1
12V18AH*4
C2*1
12V65AH*2
C3*1
12V100AH*2
C6*1
12V65AH*6
C8*1
12V65AH*8
PRO902L
4/48VDC
C2*1
12V18AH*8
C4*1
12V65AH*4
C4*1
12V100AH*4
C12*1
12V65AH*12
C16*1
12V65AH*16
PRO903L
6/72VDC
C3*1
12V18AH*12
C6*1
12V65AH*6
C6*1
12V100AH*6
C20*1
12V65AH*18
C24*1
12V65AH*24
PRO906L
8/96VDC
C8*1
12V26AH*16
C8*1
12V100AH*8
C24*1
12V65AH*24
C32*1
12V65AH*32
C20*2
12V65AH*40
REMARK
1. Without cable
from UPS
system to battery
bank.
2. All batteries
supply are
without battery
cables.
BACK UP
TIME
BATTERY
GROUP
DC BUS
(VDC)
30 MINUTES
1 HOUR
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO801L
3/36VDC
C1*1
12V26AH*3
C3*1
12V26AH*6
C3*1
12V65AH*3
C6*1
12V65AH*6
C6*1
12V100AH*6
PRO8015L
3/36VDC
C2*1
12V18AH*6
C3*1
12V65AH*3
C3*1
12V100AH*3
C6*1
12V100AH*6
C12*1
12V65AH*12
PRO802L
6/72VDC
C3*1
12V26AH*6
C6*1
12V65AH*12
C6*1
12V65AH*6
C20*1
12V26AH*36
C12*1
12V100AH*12
PRO803L
6/72VDC
C3*1
12V18AH*12
C6*1
12V65AH*6
C6*1
12V100AH*6
C12*1
12V100AH*12
C20*1
12V65AH*18
PRO806L
20/240VDC
C12*1
12V26AH*20
C4*2
12V18AH*40
C20*1
12V26AH*40
C20*1
12V100AH*20
C20*2
12V65AH*40
PRO810L
20/240VDC
C4*2
12V18AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
C20*3
12V65AH*60
C20*2
12V100AH*40
REMARK
1. Without cable
from UPS
system to battery
bank.
2. All batteries
supply are
without battery
cables.
BACK UP
TIME
BATTERY
GROUP
DC BUS
(VDC)
30 MINUTES
1 HOUR
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO806CL
20/240VDC
C12*1
12V26AH*20
C4*2
12V18AH*40
C20*1
12V26AH*40
C20*1
12V100AH*20
C20*2
12V65AH*40
PRO810CL
20/240VDC
C4*2
12V18AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
C20*3
12V65AH*60
C20*2
12V100AH*60
REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
The battery backup conguration list above are applicable for isolation transformer version of UPS system.
All specications, designs and contents are subjected to changes without prior notice.
41
Appendix
BACK UP
TIME
BATTERY
GROUP
DC BUS
(VDC)
30 MINUTES
1 HOUR
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO801RL
2/24VDC
C1*1
12V18AH*4
C2*1
12V65AH*2
C3*1
12V100AH*2
C6*1
12V65AH*6
C8*1
12V65AH*8
PRO8015RL
3/36VDC
C2*1
12V18AH*6
C3*1
12V65AH*3
C3*1
12V100AH*3
C6*1
12V100AH*6
C12*1
12V65AH*12
PRO802RL
4/48VDC
C2*1
12V18AH*8
C4*1
12V65AH*4
C4*1
12V100AH*4
C12*1
12V65AH*12
C16*1
12V65AH*16
PRO803RL
6/72VDC
C3*1
12V18AH*12
C6*1
12V65AH*6
C6*1
12V100AH*6
C20*1
12V65AH*18
C24*1
12V65AH*24
PRO806RL
20/240VDC
C12*1
12V26AH*20
C20*1
12V26AH*40
C20*1
12V65AH*20
C20*2
12V65AH*40
C20*3
12V65AH*60
PRO810RL
20/240VDC
C20*1
12V26AH*40
C20*1
12V100AH*20
C20*2
12V65AH*40
C20*2
12V100AH*40
C20*4
12V65AH*80
REMARK
1. Without cable
from UPS
system to battery
bank.
2. All batteries
supply are
without battery
cables.
BACK UP
TIME
BATTERY
GROUP
DC BUS
(VDC)
30 MINUTES
1 HOUR
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO83110L
20
C4*2
12V18AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
C20*3
12V65AH*60
C20*2
12V100AH*40
PRO83115L
20
C20*1
12V26AH*40
C20*1
12V100AH*20
C20*2
12V100AH*40
C20*4
12V65AH*80
C20*3
12V100AH*60
PRO83120L
20
C12*3
12V26AH*60
C20*2
12V65AH*40
C20*2
12V100AH*40
C20*6
12V65AH*120
C20*4
12V100AH*80
REMARK
BACK UP
TIME
BATTERY
GROUP
DC BUS
(VDC)
30 MINUTES
1 HOUR
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO83110RL
20
C4*2
12V18AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
C20*3
12V65AH*60
C20*2
12V100AH*40
PRO83120RL
20
C12*3
12V26AH*60
C20*2
12V65AH*40
C20*2
12V100AH*40
C20*6
12V65AH*120
C20*4
12V100AH*80
REMARK
1. Without cable from
UPS system to
battery bank.
2. All batteries supply
are without battery
cables.
BACK UP
TIME
BATTERY
GROUP
DC BUS
(VDC)
30 MINUTES
1 HOUR
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO83310L
20
C4*2
12V18AH*40
C20*1
12V65AH*20
C20*1
12V100AH*20
C20*3
12V65AH*60
C20*2
12V100AH*40
PRO83315L
20
C20*1
12V26AH*40
C20*1
12V100AH*20
C20*2
12V100AH*40
C20*4
12V65AH*80
C20*3
12V100AH*60
PRO83320L
20
C12*3
12V26AH*60
C20*2
12V65AH*40
C20*2
12V100AH*40
C20*6
12V65AH*120
C20*4
12V100AH*80
REMARK
The battery backup conguration list above are applicable for isolation transformer version of UPS system.
All specications, designs and contents are subjected to changes without prior notice.
42
Appendix
BACK UP
TIME
BATTERY
GROUP
DC BUS
(VDC)
30 MINUTES
1 HOUR
2 HOURS
3 HOURS
4 HOURS
QUANTITY
QUANTITY
QUANTITY
QUANTITY
QUANTITY
PRO73315S
62
C16*1
12V18AH*62
C16*2
12V18AH*124
C32*2
12V26AH*124
C32*2
12V100AH*62
C32*4
12V65AH*124
PRO73320S
62
C32*1
12V26AH*62
C16*2
12V18AH*124
C32*2
12V65AH*62
C32*2
12V100AH*62
C32*4
12V65AH*124
PRO73330S
62
C16*2
12V18AH*124
C32*2
12V65AH*62
C32*2
12V100AH*62
C32*6
12V65AH*186
C32*4
12V100AH*124
PRO73340S
62
C32*2
12V26AH*124
C32*2
12V100AH*62
C32*4
12V65AH*124
C32*4
12V100AH*124
C32*8
12V65AH*248
PRO73360S
62
C32*2
12V65AH*62
C32*4
12V65AH*124
C32*4
12V100AH*124
C32*6
12V100AH*186
C32*8
12V100AH*248
PRO73380S
62
C32*2
12V100AH*62
C32*6
12V65AH*186
C32*8
12V65AH*248
C32*8
12V100AH*248
C32*10
12V100AH*310
REMARK
1. Without cable
from UPS
system to battery
bank.
2. All batteries
supply are
without battery
cables.
Battery Configurations
MODEL NO
CABINET
DIMENSION
CI
C2
CABINET WEIGHT
65AH
40AH
26AH
18AH
435*210*270
450*470*320
1
1
1
2
2
4
3
4
5
10
12V7AH or
12V9AH or 10Ah
/
/
C3
585*470*320
14
8kg
C4
C6
450*470*615
585*470*615
4
6
4
6
8
12
8
12
20
28
/
/
18kg
22kg
C8
780*470*615
16
16
36
25kg
C12
C16
780*470*900
780*470*1190
12
16
12
16
24
32
24
32
/
62
/
/
32kg
45kg
C20
950*470*1190
20
20
40
40
45kg
C24
C32
1150*470*1190
780*880*1190
24
32
24
32
/
62
/
62
/
/
/
/
75kg
95kg
REMARK
3.5kg
6kg
1. Option for DC
switch/protection
2. Option for battery
cable inter
connection.
G6
Completed assembled
G12
12
Completed assembled
G18
G60
18
60
Completed assembled
completed assembled
G8R
Completed assembled
G12R
12
Completed assembled
G20R
20
Completed assembled
The battery backup conguration list above are applicable for isolation transformer version of UPS system.
All specications, designs and contents are subjected to changes without prior notice.
43
Note
44
SINGAPORE
FIDA INTERNATIONAL (S) PTE LTD
Block 16 Kallang Place
#06-02, Singapore 339156
Tel: (65) 6357 0668
MALAYSIA
FIDA SYSTEMS (M) SDN BHD
Tel: (60) 3 8024 9151
INDONESIA
PROLiNK INDONESIA
Tel: (62) 21 3483 1777
Technical Support Hotline:
Singapore (65) 6357 0666
Malaysia (60) 3 8023 9151
Indonesia (62) 21 3482 1717
Operating Hours
Monday - Friday: 9.00am - 6.00pm