Product Version
V100R008
Prepared by
Date
Reviewed by
Date
Approved by
Date
2009-07-20
INTERNAL
2015-3-9
Abbreviatio
ns
Explanation
BTS
MS
Mobile Station
BSC
Huawei Confidential
Page 2 of 129
INTERNAL
Contents
1 Introduction to the GBTS3900 IP Site...........................................13
1.1 HDLC Site.......................................................................................................................................................13
1.2 HDLC HUB Site..............................................................................................................................................14
1.3 IP Site...............................................................................................................................................................14
2015-3-9
Huawei Confidential
Page 3 of 129
INTERNAL
5 Troubleshooting........................................................................126
5.1 Basic Operations for Site Troubleshooting....................................................................................................126
5.1.1 Basic Operations for Troubleshooting an HDLC or HDLC HUB Site................................................126
5.1.2 Basic Operations for Troubleshooting an IP Site.................................................................................126
5.2 FAQ................................................................................................................................................................127
5.2.1 IP Site Problems...................................................................................................................................127
5.2.2 HDLC Site Problems............................................................................................................................127
6 Appendix.................................................................................. 128
6.1 LEDs on the TMU Board...............................................................................................................................128
6.2 References......................................................................................................................................................129
2015-3-9
Huawei Confidential
Page 4 of 129
INTERNAL
Figures
Figure 2-1 Network topology................................................................................................................................17
Figure 2-2 Network topology................................................................................................................................18
Figure 2-3 Layer 3 networking model..................................................................................................................20
Figure 2-4 Adding a route in layer 3 networking mode........................................................................................21
Figure 2-5 Network topology................................................................................................................................22
Figure 2-6 Layer 2 networking model..................................................................................................................24
Figure 2-7 Network topology................................................................................................................................25
Figure 2-8 Network topology................................................................................................................................26
Figure 2-9 PTN networking..................................................................................................................................28
Figure 2-10 Maintain Clock dialog box................................................................................................................29
Figure 2-11 Set Clock Information dialog box.....................................................................................................30
Figure 2-12 Site Attributes dialog box..................................................................................................................31
Figure 2-13 Set Clock Information dialog box.....................................................................................................32
Figure 2-14 Position of the clock server in a network..........................................................................................33
Figure 2-15 Configuring the clock on the BSC6000 LMT...................................................................................34
Figure 3-1 Adding a site........................................................................................................................................36
Figure 3-2 Add Site dialog box.............................................................................................................................36
Figure 3-3 Add New Site dialog box....................................................................................................................37
Figure 3-4 Add Cell dialog box.............................................................................................................................38
Figure 3-5 Add New Cell dialog box....................................................................................................................39
Figure 3-6 Configure Site Attributes dialog box...................................................................................................39
Figure 3-7 Adding the RXU chain........................................................................................................................40
Figure 3-8 Add RXU Chain dialog box................................................................................................................40
Figure 3-9 RXU chain added................................................................................................................................41
Figure 3-10 Adding the RXU................................................................................................................................41
Figure 3-11 Setting the RXU name and number...................................................................................................42
2015-3-9
Huawei Confidential
Page 5 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 6 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 7 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 8 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 9 of 129
Tables
Table 3-1 Comparison between the port IP address and the device IP address.....................................................83
Table 3-2 Network planning in the lab..................................................................................................................84
INTERNAL
the multiplexing mechanism. In downstream direction, the site needs to obtain its site
information from the HDLC channel. In upstream direction, the site needs to share the
resource sent through the HDLC channel.
1.3 IP Site
The IP site is different from the HDLC site. The transmission network between the BSC and
the IP site is carried over IP. The control plane and the service plane are carried according to
the optimized Abis transmission solution.
Compared with traditional networks, the IP network is competitive in new service support,
high bandwidth, and networking costs. The advantages are described as follows:
High performance, such as bandwidths of 100 Mbit/s and 1000 Mbit/s resolving the
bottleneck of 2 Mbit/s based transmission, high forwarding capabilities, and high
efficiency
Flexible maintenance, such as simple operation and maintenance over IP, flexible routing
configuration, and ease of disaster tolerance
Cost effectiveness, such as low costs of network building and maintenance, developed IP
technology, time-saving network building
Between the BSC and the BTS, the Abis interface uses IP over FE for transmission. The
DPTU transmission module implements the exchange of upstream packets from the GTMU to
the TRX over an OML, RSL, and TRAU. The transmission module also implements the
exchange of upstream packets to the Fast Ethernet (FE). In addition, the transmission module
implements BSC loopback and BTS loopback.
In IP transmission mode, the software version supports only the electrical-port communication instead of
the optical-port communication and IP over E1.
After obtaining the IP address through DHCP, the IP site automatically learns the gateway address. As
only one gateway address can be obtained, you must ensure that all the devices that communicate with
the BTS (for example, IPCLK Server) use the gateway address.
2015-3-9
Huawei Confidential
Page 14 of 129
INTERNAL
2.1 Concepts
2.1.1 IP Address and Mask
Device IP: Generally, the IP address identifies only one interface. If a device has multiple
interfaces, multiple IP addresses must be configured for the device. For the purpose of clear
management, the device IP address is introduced to logically identify a device, for example,
BTS. When the BTS communicates with the BSC, the device IP address is used to transmit
data.
Port IP: It refers to the IP address of the physical port on the BTS BBU.
Subnet mask: It is a 32-bit numeral corresponding to the IP address. Generally, the more
significant bits of the subnet mask are continuous 1s and the less significant bits are
continuous 0s. The subnet mask divides the IP address into two parts: subnet IP address and
host IP address. In the IP address and subnet mask, the part corresponding to bit 1 is the
subnet IP address and the part corresponding to other bits is the host IP address.
To check whether two IP addresses are on the same network segment, AND the two IP
addresses with their own subnet masks. If the operation results are the same, the two IP
addresses are on the same network segment.
For example:
192.168.1.0/255.255.255.0 is divided into two subnets as follows:
192.168.1.0/255.255.255.128 and 192.168.1.128/255.255.255.128
The 255.255.255.128 subnet mask is a 25-bit mask. The 192.168.1.0 network segment is
divided into two subnets, and each subnet has 126 IP addresses.
In practice, to save IP address resources, the customer requires a large subnet mask (for
example, 29-bit or 30-bit subnet mask) and about 10 IP addresses on each network segment.
Therefore, when configuring IP addresses, you must check whether they are on the same
network segment. As a route is required for communication between network segments, the IP
communication may fail due to no route configuration.
2015-3-9
Huawei Confidential
Page 15 of 129
INTERNAL
Subnet mask: The subnet mask, together with the destination address, identifies the
address of the network segment of the destination host or router. That is, the address of
the network segment of the destination host or router can be obtained by ADDing the
destination address with the subnet mask.
Outgoing port: It refers to the port of the router through which an IP packet is forwarded.
IP address of next hop: It indicates the next router that an IP packet reaches. The address
is called a gateway address on the BSC.
2015-3-9
Huawei Confidential
Page 16 of 129
INTERNAL
Networking description:
The BSC is directly connected to Router A and Router B with FE&GE cables. Router A
is a master router, and Router B is a slave router.
The FE/GE interface board of the BSC is FG2a, and the GE port is recommended.
The clock reference source of the BTS can be GPS, IPCLOCK, or MSTP.
VLAN tags are attached by the switching equipment on the access side (the versions
later than V100R008C11 support VLAN).
The transmission network between the L3 equipment and BTS requires VLAN, QoS, and
DHCP relay. The functions, together with wireless equipment, form a complete solution.
2015-3-9
Huawei Confidential
Page 17 of 129
INTERNAL
Redundancy configuration: The BSC boards work in active/standby mode, and the
corresponding ports on the active and standby boards work in active/standby mode. It is
recommended that you directly connect the BSC to the routers for L3 networking.
IP address configuration: IP1 is the IP address of the BSC interface that is used to carry
services and signaling, and a 29-bit mask is used for the IP address.
Detection mechanism: The ARP detection is enabled on the active port. The gateway IP
address to be detected is VRRP Virtual IP and the expiry time is three seconds. If no ARP
packet is received successively three times, an alarm is reported. The interface addresses
from the active and standby ports to the routers are detected by physical ports.
Port1, Port2, Port3, Port4, Port5, and Port6 are configured to work in Portswitch mode
and belong to VLAN A. Port2, Port5, Port4, and Port6 are bound to a trunk and Permit
all VLAN is configured.
Port7 and Port8 are routing ports and the dynamic routing protocol is enabled.
Networking description:
2015-3-9
Huawei Confidential
Page 18 of 129
INTERNAL
The BSC is accessed to the transmission network through FE&GE. The FE&GE traffic is
converged to an OSN across two routers.
The VLAN configuration is recommended. VLAN tags are attached by the switching
equipment or transmission equipment, and the VLAN is transparent to wireless
equipment.
Redundancy configuration: The BSC boards work in active/standby mode, and the
corresponding ports on the active and standby boards work in active/standby mode. It is
recommended that you directly connect the BSC to the routers for L3 networking.
IP address configuration: IP1 is the IP address of the BSC interface that is used to carry
services and signaling.
Detection mechanism: The ARP detection is enabled on the active port. The gateway IP
address to be detected is VRRP Virtual IP and the expiry time is three seconds. If no ARP
packet is received successively three times, an alarm is reported. The interface addresses
from the active and standby ports to the routers are detected by physical ports.
Port configuration: The ports on Router A and Router B are routing ports, and the
dynamic routing protocol is enabled between Router A and Router B.
The router works with the MSTP equipment for BPS switchover. As only one port on the two
routers that are connected to the MSTP equipment is UP, one router in VRRP2 is a master
router and the other router is an initial router.
Configuration
Figure 1.1 shows the configurations of the port IP addresses and device IP address of the
BSC, and a BTS is to be created in the subnet that is separated by multiple routers from the
subnet of the BSC.
2015-3-9
Huawei Confidential
Page 19 of 129
INTERNAL
Figure 1.1 shows a typical layer 3 networking model. The cloud chart indicates multiple
subnets. To ensure that Router A can communicate with Router B, do as follows:
2015-3-9
Configure the IP address of the BTS as an IP address on the subnet segment of the BTS.
If the subnet segment of the BTS is 192.12.12.1/24, you can specify any idle IP address
in the range of 192.12.12.1 to 192.12.12.254 to the BTS.
Configure a route on the BSC. The destination IP address is the IP address of the BTS
and the next hop is the IP address of port A of Router B. The data sent by the BSC to the
BTS can be sent to Router B through the route. Figure 1.2 shows the route configuration
on the BSC.
Huawei Confidential
Page 20 of 129
INTERNAL
Configure a route on Router B. The destination IP address is the IP address of the BTS
and the next hop is the IP address of the equipment (port D) that is connected to port B of
Router B. The data sent by the BSC to the BTS can be sent from port B of Router B to
the next router through the route. The configuration procedure is as follows:
To add a route (the destination IP address is 192.12.12.1, the mask is a 24-bit mask, and
the next hop is 192.12.14.3), run the following command:
[Quidway]ip route-static 192.12.12.1 24 192.12.14.3
To delete a route, run the following command:
[Quidway]undo ip route-static 192.12.12.1 24 192.12.14.3
To query route information, run the following command:
[Quidway]dis ip routing-table
Routing Table: public net
Destination/Mask Protocol Pre Cost
192.12.12.1 /24
2015-3-9
STATIC 60 0
Nexthop
Interface
192.12.14.3 Vlan-interface2
Configure a route on the Router B. The destination IP address is the device IP address of
the BSC and the next hop is the port IP address of BSC. The data sent by the BTS to the
BSC can be sent from port B of Router B to the BSC through the route. The
configuration procedure is the same as the preceding one.
Configure a route on Router A. The destination IP address is the device IP address of the
BSC and the next hop is the IP address of the equipment (port C) that is connected to
port B of Router A. The data sent by the BTS to the BSC can be sent from port B of
Router A to the next router through the route. The configuration procedure is the same as
the preceding one.
Configure the DHCP relay on Router A (on the local BTS side). The IP address of the
DHCP server is the port IP address of the interface board on the BSC side. The BTS can
Huawei Confidential
Page 21 of 129
INTERNAL
obtain IP addresses from the BSC servers in different subnets only after the DHCP relay
is configured. The configuration procedure is as follows:
To enable the DHCP service, run the following command:
[Quidway] dhcp enable
To create a DHCP server with group number 1 (the IP address of the DHCP server is
192.19.19.19 (device IP address of the BSC)), run the following command:
[Quidway] dhcp-server 1 ip192.19.19.19
To enter the vlan1 view (port A of Router A belongs to VLAN 1), run the following
command:
[Quidway] interface vlan-interface 1
To add VLAN 1 to DHCP server group 1, run the following command:
[Quidway-Vlan-interface1] dhcp-server 1
To query the information on the DHCP server, run the following command:
[Quidway] display dhcp-server all
To query the mapping between the DHCP server and VLAN interfaces, run the following
command:
[Quidway] display dhcp-server interface Vlan-interface
Networking description:
2015-3-9
Huawei Confidential
Page 22 of 129
INTERNAL
The two-line bidirectional multiplex section protection ring can be used in MSTP
network to improve the reliability.
The VLAN configuration is recommended. VLAN tags are attached by the transmission
equipment to ports, and the VLAN is transparent to wireless equipment.
Redundancy configuration: The BSC uses the GE interface boards. The boards work in
active/standby mode, and the corresponding ports on the active and standby boards work
in active/standby mode (or link aggregation can be used to provide higher reliability).
IP address configuration: IP1 is the IP address of the BSC interface that is used to carry
services and signaling.
The MSTP equipment uses the GE (HUAWEI OSN: EMS4) interface board, and the port
PPS protection is configured.
When the port on the OSN is deactivated, the active and standby ports are simultaneously
deactivated. In this case, the transmission is disconnected. Therefore, you cannot deactivate
the port.
Configuration
Figure 1.1 shows the configurations of the port IP addresses and device IP address of the
BSC, and a BTS is to be created in the subnet of the BSC.
2015-3-9
Huawei Confidential
Page 23 of 129
INTERNAL
Figure 1.1 shows a typical layer 2 networking model. The dashed line indicates that there are
one or more switches between Switch A and Switch B. To ensure that Switch A can
communicate with Switch B, do as follows:
2015-3-9
Configure the IP address of the BTS as an IP address on the subnet segment of the port
IP address of the BSC. As the port IP address of the BSC is 192.12.15.1/24, you can
specify any idle IP address in the range of 192.12.15.1 to 192.12.15.254 to the BTS.
Huawei Confidential
Page 24 of 129
INTERNAL
Advantages:
A VLAN is configured for each BTS. As the VLANs are used to distinguish BTSs and
paths, the network structure is clear, the configuration is simple, and the internal faults
can be located easily.
On the BTS side, the transmission equipment divides VLANs for wireless services by
ports. On the BSC side, VLAN tags are attached for services by BTSs.
The VLAN isolation ensures network security and no broadcast storm occurs.
Disadvantages:
2015-3-9
Huawei Confidential
Page 25 of 129
INTERNAL
Too many VLANs are required. If independent VLANs are configured for the OM, the
consumption of VLAN resources is larger. In addition, the BSC is required to have
higher VLAN capability.
The VLAN ID must be unique. If the VLANs are reused between regions, the planning
and configuration are very difficult.
When the wireless side and transmission side are based on VLAN tight coupling, an
error easily occurs, the flexibility is poor, and the expansion and adjustment in the future
are very difficult.
Scenario 2: EVPLAN
Figure 1.1 Network topology
Advantages:
2015-3-9
Huawei Confidential
Page 26 of 129
INTERNAL
As the MAC address switching is used, the VLAN quantity is reduced. In this case, the
site launching and swapping are easier and the speed is quicker.
It is unnecessary to set up an end-to-end unique VLAN channel for each BTS. In this
case, manual configuration errors in the wireless and MSTP networks can be reduced.
Disadvantages:
When a packet is forwarded on the basis of the MAC address in the MSTP network, the
problem location and the maintenance are difficult.
To prevent the port loopback from affecting services, you need to disable the loopback
on any port (including Ethernet port and VCTRUNK optical cable) or upgrade the MSTP
network to support the Ethernet OAM feature that automatically blocks the port
loopback.
The EVPLAN solution is recommended to save VLAN resources and reduce the
configuration complexity. The networking details are as follows:
MSTP uses 2-level convergence, and the EVPLAN solution is used for both level 1 and
level 2. EGS4 is mapped on the basis of MAC and VC.
The OSN and CE use the BPS+VRRP networking mode. To prevent the network storm
and identify the L2 priority, you are advised to assign one VLAN ID to a maximum of 50
BTSs under a BSC.
The Ethernet port of the transmission equipment at the access layer is configured to work
in Hybrid mode for commissioning before site launching.
You are advised to configure one VLAN for the BTSs under two pairs of EGS4s in the
level 1 convergence (in the level 1 convergence, a pair of EGS4s support a maximum of
64 BTSs). The IP addresses are planned on the same network segment so that the CE
attaches VLAN tags based on the IP addresses.
In the level 2 convergence, one BSC is configured with a pair of EGS4s. In phase 1, each
pair of boards are configured with a pair of GE ports. For the later expansion, two pairs
of GE ports are configured.
The VLAN tags of downlink services on the BSC side are attached by the layer 3
equipment based on the destination IP address, and the VLAN tags of uplink services on
the BTS side are attached by the transmission equipment based on ports.
2015-3-9
Huawei Confidential
Page 27 of 129
INTERNAL
2.3 Clock
The clock synchronization solution of the GSM IP BSS is related to the networking solution.
The actual network involves the following clock modes:
IP clock: The IP clock server is connected to support a maximum of 512 clients.
Trace transport clock: The E1 line is connected.
External synchronization clock: The clock source is connected.
Trace GPS clock: The DGPS of the BSC is connected.
Method 1
Step 1 Right-click the GTMU of the BTS whose clock mode is to be changed, and then choose
Maintain Clock from the shortcut menu. In the Maintain Clock dialog box, right-click the
attribute list, and then choose Set Clock from the shortcut menu, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 28 of 129
INTERNAL
Step 2 In the Set Clock Information dialog box, select Clock Mode and Trace Mode, and then
click Set, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 29 of 129
INTERNAL
Internal clock: The BTS does not trace the external clock, and the internal high-precision
clock works in free-run mode.
External synchronization clock: The internal high-precision clock of the BTS traces the
external synchronization clock signals.
IP clock: The BTS synchronizes the clock with the IP clock server through the IP
network.
Trace GPS clock: The BTS extracts and synchronizes the clock from the GPS through
the DGPS.
Trace BSC clock: The internal high-precision clock signals of the BTS trace the clock
signals from the BSC.
2015-3-9
If the IP transmission mode is used, Trace Transport Clock can be configured and
Trace BSC Clock cannot be configured.
If the non-IP transmission mode is used, Trace BSC Clock can be configured and Trace
Transport Clock cannot be configured.
The BTS obtains the clock signals from the E1 port regardless of whether Trace BSC
Clock or Trace Transport Clock is configured.
When Trace BSC Clock is configured, you do not need to configure the E1 port from
which the clock signals are obtained.
When Trace Transport Clock is configured, you need to configure the E1 port from
which the clock signals are obtained.
Huawei Confidential
Page 30 of 129
INTERNAL
If Disable Trace Range Limit is selected, the BTS always traces the upper-level
reference clock.
If Enable Trace Range Limit is selected and |f| 2 Hz, the reference clock is traced. If
Enable Trace Range Limit is selected and |f| > 2 Hz, the internal clock works in freerun mode and the reference clock is not traced.
----End
Method 2
Step 1 On the LMT, right-click the target site in the navigation tree on the left, and then choose Site
Operation > Configure Site Attributes from the shortcut menu. In the Site Attributes
dialog box, click the Basic Information tab, and then change the setting of Reference Clock
Source Type, as shown in Figure 1.1.
Figure 1.1 Site Attributes dialog box
2015-3-9
Huawei Confidential
Page 31 of 129
INTERNAL
Both method 1 and method 2 can be used to set the clock mode of the BTS. If method 2 is
used, you can also change the setting of Clock Mode as described in method 1. See IStep
1Figure 1.1. If method 1 is used, the setting of Reference Clock Source Type cannot be
changed as described in method 2. Thus, if the settings of the two parameters are inconsistent,
the setting of Clock Mode is valid.
If the offset of the DA calibration value is high during the deployment, the lock time of the
clock is long. In this case, you need to adjust the DA calibration value on the LMT.
Step 2 Right-click the GTMU of the BTS whose DA value is to be changed, and then choose
Maintain Clock from the shortcut menu.
Step 3 In the Maintain Clock dialog box, right-click the attribute list, and then choose Set Clock
from the shortcut menu.
Step 4 Select Set Calibration Value in the Set Clock Information dialog box, as shown in Figure
1.1.
Figure 1.1 Set Clock Information dialog box
----End
2015-3-9
Huawei Confidential
Page 32 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 33 of 129
INTERNAL
----End
1.To ensure that the clock frequency output by the clock server is a standard reference source,
you must calibrate the clock server before using it.
2.The value of ShakeHandPeriodB must be greater than the values of ShakeHandPeriodA
and ShakeHandPeriodC.
2015-3-9
Huawei Confidential
Page 34 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 35 of 129
INTERNAL
Step 2 The Add Site dialog box is displayed, as shown in Figure 1.1. Click Add Site.
Figure 1.1 Add Site dialog box
Step 3 In the Add New Site dialog box, type Site Name, and set Site Type to BTS3900 GSM and
Service Mode to HDLC. Click OK to finish the configuration, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 36 of 129
INTERNAL
1.This dialog box may vary with different BSC versions, but the configuration process is the same.
2.The Cfg RFU by Slot check box is not selected when adding a new site. The future configuration
could be based on the RXU topological structure.
2015-3-9
Huawei Confidential
Page 37 of 129
INTERNAL
The following describes the meanings of the parameters in the Add New Site dialog box.
Ring Mode: The value of this parameter is either YES or NO. YES indicates that the
cascading of BTSs is supported and the ring network is established. Thus, if any BTS in
the cascaded BTSs is disconnected, all the other BTSs can still communicate with the BSC
properly. Abis By Pass Mode cannot be set regardless of whether Ring Mode is set.
Step 4 Return to the Add Site dialog box and click Next. In the Add Cell dialog box, click Add
Cell, as shown in Figure 1.1.
If you click Add Site again when you return to the Add Site dialog box, a cascaded site of the
previously added site can be added.
Figure 1.1 Add Cell dialog box
Step 5 In the Add New Cell dialog box, set Cell Index (ranging from 0 to 2047, uniquely identifying
a cell in a BSC), Cell Name, and Frequency Band. Then click OK to finish the
configuration, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 38 of 129
INTERNAL
Step 6 Return to the Add Cell dialog box and click Next. In the Configure Site Attributes dialog
box, click Site Attributes, as shown in Figure 1.1.
Figure 1.1 Configure Site Attributes dialog box
Step 7 In the Site Device Attributes dialog box, right-click the icon under RXU topological
structure, and then choose Add RXU Chain from the shortcut menu, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 39 of 129
INTERNAL
Step 8 In the Add RXU Chain dialog box, set Chain Type and Chain Head Board Port. Chain
Head Board Port is the port number of the SFP where the TRX is connected, that is, the
CPRI port; Chain Type can be Chain or Ring depending on actual scenarios. The chain or
ring here indicates the topological structure of the TRX. Then, click OK. Figure 1.1 takes
adding a chain on SFP 0 of the GTMU as an example.
Figure 1.1 Add RXU Chain dialog box
2015-3-9
Huawei Confidential
Page 40 of 129
INTERNAL
Step 9 Return to the Site Device Attributes dialog box and right-click the added chain, and then
choose Add RXU > Add GRFU from the shortcut menu, as shown in Figure 1.1.
Figure 1.1 Adding the RXU
Step 10 In the Add GRFU dialog box, set RXU NAME and RXU No., as shown in Figure 1.1. Then,
click OK.
2015-3-9
Huawei Confidential
Page 41 of 129
INTERNAL
Step 11 Return to the Site Device Attributes dialog box and right-click the added RXU chain, and
then choose Binding logical TRX from the shortcut menu, as shown in Figure 1.1.
Figure 1.1 Binding logical TRXs
Step 12 In the Binding logical TRX dialog box, select Trx No. and set Assigned Cell.
2015-3-9
Select the logical TRX that you want to bind to the RXU board.
If you bind a logical TRX to the RXU board, you need to set a TRX number and select a
cell for it.
If you bind a GRRU logical TRX, you need to select a transmitting channel A or B.
Huawei Confidential
Page 42 of 129
INTERNAL
Step 13 Right-click the added chain, and then choose Configure RXU Attribute from the shortcut
menu. The Configure Site Board Attributes tab page is displayed, as shown in Figure 1.1.
Figure 1.1 Configure Site Board Attributes tab page
2015-3-9
Huawei Confidential
Page 43 of 129
INTERNAL
Step 14 If a new site board is to be cascaded with the new GRFU, right-click the GRFU, and then
choose Add RXU > Add GRFU, as shown in Figure 1.1. The parameter settings are the same
as those described in the preceding section.
Figure 1.1 Adding a cascaded GRFU
Step 15 To add a board over a different port, repeat Step 7 through Step 14. In RXU topological
structure, add all required RXU boards and logical TRXs. Then, in the Site Device
Attributes dialog box, click OK. When you add cells in batches, ensure that each cell is
configured with at least one carrier.
Step 16 In the Add Site dialog box. If you want to add a chain, click Configure Chain, as shown in
Figure 1.1. Otherwise, continue with Step 19.
2015-3-9
Huawei Confidential
Page 44 of 129
INTERNAL
Step 17 In the Add or Delete Site Chain dialog box, click Add Chain, as shown in Figure 1.1.
Figure 1.1 Add or Delete Site Chain dialog box
Step 18 In the Add Site Slave Chain dialog box, set a port. Then, click OK. See Figure 1.1. In the
Add or Delete Site Chain dialog box, click OK.
2015-3-9
Huawei Confidential
Page 45 of 129
INTERNAL
Step 19 After you set the site attributes, in the Add Site dialog box, click Next. Then, click Cell
Attributes, as shown in Figure 1.1.
Figure 1.1 Configuring cell attributes
Step 20 In the Set Cell Attributes dialog box, set the cell attributes as required, as shown in Figure
1.1.
2015-3-9
Huawei Confidential
Page 46 of 129
INTERNAL
Set parameters MCC, MNC, LAC, CI, NCC, and BCC to the same values as those on the
MSC side.
Figure 1.1 Set Cell Attributes dialog box
Step 21 In the Set Cell Attributes dialog box, double-click the TRX under Assigned TRXs or click
Frequency Config to configure required frequencies, as shown in Figure 1.1. In the Set Cell
Frequency dialog box, select the frequencies to be set, as shown in Figure 1.2.
2015-3-9
Huawei Confidential
Page 47 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 48 of 129
INTERNAL
When setting the frequencies of the GRFU, the bandwidth cannot exceed 15 MHz owing
to the limit of the frequency bandwidth. That is, there should be no greater than 74
frequencies between the highest frequency and the lowest frequency because the
difference between the two adjacent frequencies is 200 kbit/s.
When setting the frequencies of the GRRU, the bandwidth cannot exceed 12.5 MHz owing
to the limit of the frequency bandwidth. That is, there should be no greater than 61
frequencies between the highest frequency and the lowest frequency because the
difference between the two adjacent frequencies is 200 kbit/s.
There are no limitations for the frequencies of the DRRU and DRFU.
Step 22 Return to the Set Cell Attributes dialog box (as shown in Step 20Figure 1.1) to set the
frequency and attributes of the TRXs.
2015-3-9
Click the Frequency Attributes tab page to set the TRX frequency, as shown in Figure
1.1.
Click the Channel Attributes tab page to set the channel attributes of the TRXs, as
shown in Figure 1.2.
Click the Device Attributes tab page to set the parameters such as Power Level,
Receive Mode, and Send Mode, as shown in Figure 1.3.
Huawei Confidential
Page 49 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 50 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 51 of 129
INTERNAL
After the cell attributes are configured, click OK, as shown in Figure 1.4.
Figure 1.4 Set Cell Attributes dialog box
Step 23 Click Finish to complete the cell configuration, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 52 of 129
INTERNAL
----End
Huawei Confidential
Page 53 of 129
INTERNAL
For details about the LEDs on the TMU panel, see 6.1 "LEDs on the TMU Board."
2015-3-9
Huawei Confidential
Page 54 of 129
INTERNAL
In the Move Site dialog box, select the target site from the Site View area, and then click
Move Site, as shown in Figure 1.2.
Figure 1.2 Moving a site (2)
In the Move Site dialog box, select HDLC to change the TDM site to the HDLC site, as
shown in Figure 1.3. Click BSC Port. In the displayed dialog box, click YES. The Choice
Board&Port dialog box is displayed, as shown in Figure 1.4.
2015-3-9
Huawei Confidential
Page 55 of 129
INTERNAL
Set the parameters Dest SubRack No., Dest Slot No., and Dest Port No. to proper values
based on the GEHUB position. Then, click OK. In the displayed dialog box, click OK to
return to the Move Site dialog box, and then click Next, as shown in Figure 1.5.
2015-3-9
Huawei Confidential
Page 56 of 129
INTERNAL
In the displayed Move Site dialog box, the original connection of the site and the connection
after the site is moved are available in the Move Site Result area. Ensure that the current
connection of the site is correct, and then click Finish, as shown in Figure 1.6.
Figure 1.6 Result of moving a site (1)
2015-3-9
Huawei Confidential
Page 57 of 129
INTERNAL
Click Continue, as shown in Figure 1.7. After the timeslots in the TDM site are arranged, a
message is displayed to prompt you to confirm the operation. Then, click OK.
Figure 1.7 Result of moving a site (2)
Step 3 Remove the E1 cable that connects the TDM site to the GEIUB. Then, insert the E1 cable into
the GEHUB in the BSC rack. (Remove the original E1 cable that connects the TDM site to
the GEIUB in the BSC rack, and then insert the cable into the corresponding port on the
GEHUB that is connected to the added HDLC site.) The OML is established after two
minutes and the RSL is established after five minutes.
Step 4 After the previous operations, the site still runs properly. The services processed on the site
are disrupted for about 15 minutes during the entire process.
----End
Method 2: Upgrade a TDM site on the existing network to an HDLC site by directly
building an HDLC site
If the existing TDM site is attached to the GEIUB board, you can perform the following
operations on the BSC LMT:
Configuring an HDLC Site (For details, see 3.2.1 "Adding an HDLC Site on the BSC6000
LMT.") > Preparing the E1 Line from the BSC to the Site > Loading the Latest Version of the
TMU > Disconnecting the Existing Network Cable from the TDM Site and Inserting the E1
Line into the Subrack > Activating the TMU Version > Loading the Latest Version of the TRX
> Activating the TRX Version
For details on how to connect the hardware and the transmission network, see 3.2.2
"Configuring Hardware and the Transmission Network."
2015-3-9
Huawei Confidential
Page 58 of 129
INTERNAL
Step 2 The Add Site dialog box is displayed, as shown in Figure 1.1. Click Add Site.
2015-3-9
Huawei Confidential
Page 59 of 129
INTERNAL
Step 3 In the Add New Site dialog box, type Site Name, and set Site Type to BTS3900 GSM and
Service Mode to HubBTS. Click OK to finish the configuration, as shown in Figure 1.1.
1.This dialog box may vary with different BSC versions, but the configuration process is the same.
2.The Cfg RFU by Slot check box is not selected when adding a new site. The future configuration
could be based on the RXU topological structure.
2015-3-9
Huawei Confidential
Page 60 of 129
INTERNAL
Step 4 Return to the Add Site dialog box and click Next. In the Add Cell dialog box, click Add
Cell, as shown in Figure 1.1.
If you click Add Site again when you return to the Add Site dialog box, a cascaded site of the
previously added site can be added.
2015-3-9
Huawei Confidential
Page 61 of 129
INTERNAL
Step 5 In the Add New Cell dialog box, set Cell Index (ranging from 0 to 2047, uniquely identifying
a cell in a BSC), Cell Name, and Frequency Band. Then click OK to finish the
configuration, as shown in Figure 1.1.
Figure 1.1 Add New Cell dialog box
Step 6 Return to the Add Cell dialog box and click Next. In the Configure Site Attributes dialog
box, click Site Attributes, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 62 of 129
INTERNAL
Step 7 In the Site Device Attributes dialog box, right-click the icon under RXU topological
structure, and then choose Add RXU Chain from the shortcut menu, as shown in Figure 1.1.
Figure 1.1 Adding the RXU chain
Step 8 In the Add RXU Chain dialog box, set Chain Type and Chain Head Board Port. Chain
Head Board Port is the port number of the SFP where the TRX is connected, that is, the
CPRI port; Chain Type can be Chain or Ring depending on actual scenarios. The chain or
ring here indicates the topological structure of the TRX. Then, click OK. Figure 1.1 takes
adding a chain on SFP 0 of the GTMU as an example.
2015-3-9
Huawei Confidential
Page 63 of 129
INTERNAL
Step 9 Return to the Site Device Attributes dialog box and right-click the added chain, and then
choose Add RXU > Add GRFU from the shortcut menu, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 64 of 129
INTERNAL
Step 10 In the Add GRFU dialog box, set RXU NAME and RXU No., as shown in Figure 1.1. Then,
click OK.
Figure 1.1 Setting the RXU name and number
Step 11 Return to the Site Device Attributes dialog box and right-click the added RXU chain, and
then choose Binding logical TRX from the shortcut menu, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 65 of 129
INTERNAL
Step 12 In the Binding logical TRX dialog box, select Trx No. and set Assigned Cell.
Select the logical TRX that you want to bind to the RXU board.
If you bind a logical TRX to the RXU board, you need to set a TRX number and select a
cell for it.
If you bind a GRRU logical TRX, you need to select a transmitting channel A or B.
Then, click OK, as shown in Figure 1.1.
Step 13 Right-click the added chain, and then choose Configure RXU Attribute from the shortcut
menu. The Configure Site Board Attributes tab page is displayed, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 66 of 129
INTERNAL
Step 14 If a new site board is to be cascaded with the new GRFU, right-click the GRFU, and then
choose Add RXU > Add GRFU, as shown in Figure 1.1. The parameter settings are the same
as those described in the preceding section.
Figure 1.1 Adding a cascaded GRFU
2015-3-9
Huawei Confidential
Page 67 of 129
INTERNAL
Step 15 To add a board over a different port, repeat Step 7 through Step 14. In RXU topological
structure, add all required RXU boards and logical TRXs. Then, in the Site Device
Attributes dialog box, click OK. When you add cells in batches, ensure that each cell is
configured with at least one carrier.
Step 16 In the Add Site dialog box. If you want to add a chain, click Configure Chain, as shown in
Figure 1.1. Otherwise, continue with Step 19.
Figure 1.1 Configuring a chain
Step 17 In the Add or Delete Site Chain dialog box, click Add Chain, as shown in Figure 1.1.
Figure 1.1 Add or Delete Site Chain dialog box
Step 18 In the Add Site Slave Chain dialog box, set a port. Then, click OK. See Figure 1.1. In the
Add or Delete Site Chain dialog box, click OK.
2015-3-9
Huawei Confidential
Page 68 of 129
INTERNAL
Step 19 After you set the site attributes, in the Add Site dialog box, click Next. Then, click Cell
Attributes, as shown in Figure 1.1.
Figure 1.1 Configuring cell attributes
Step 20 In the Set Cell Attributes dialog box, set the cell attributes as required, as shown in Figure
1.1.
2015-3-9
Huawei Confidential
Page 69 of 129
INTERNAL
Set parameters MCC, MNC, LAC, CI, NCC, and BCC to the same values as those on the
MSC side.
Figure 1.1 Set Cell Attributes dialog box
Step 21 In the Set Cell Attributes dialog box, double-click the TRX under Assigned TRXs or click
Frequency Config to configure required frequencies, as shown in Figure 1.1. In the Set Cell
Frequency dialog box, select the frequencies to be set, as shown in Figure 1.2.
2015-3-9
Huawei Confidential
Page 70 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 71 of 129
INTERNAL
When setting the frequencies of the GRFU, the bandwidth cannot exceed 15 MHz owing
to the limit of the frequency bandwidth. That is, there should be no greater than 74
frequencies between the highest frequency and the lowest frequency because the
difference between the two adjacent frequencies is 200 kbit/s.
When setting the frequencies of the GRRU, the bandwidth cannot exceed 12.5 MHz owing
to the limit of the frequency bandwidth. That is, there should be no greater than 61
frequencies between the highest frequency and the lowest frequency because the
difference between the two adjacent frequencies is 200 kbit/s.
There are no limitations for the frequencies of the DRRU and DRFU.
Step 22 Return to the Set Cell Attributes dialog box (as shown in Step 20Figure 1.1) to set the
frequency and attributes of the TRXs.
2015-3-9
Click the Frequency Attributes tab page to set the TRX frequency, as shown in Figure
1.1.
Click the Channel Attributes tab page to set the channel attributes of the TRXs, as
shown in Figure 1.2.
Click the Device Attributes tab page to set the parameters such as Power Level,
Receive Mode, and Send Mode, as shown in Figure 1.3.
Huawei Confidential
Page 72 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 73 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 74 of 129
INTERNAL
2015-3-9
Huawei Confidential
Page 75 of 129
INTERNAL
Step 23 Click Finish to complete the cell configuration, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 76 of 129
INTERNAL
----End
Huawei Confidential
Page 77 of 129
INTERNAL
For details about the LEDs on the TMU panel, see 6.1 "LEDs on the TMU Board."
2015-3-9
Huawei Confidential
Page 78 of 129
INTERNAL
In the Move Site dialog box, select the target site from the Site View area, and then click
Move Site, as shown in Figure 1.2.
Figure 1.2 Moving a site (2)
In the Move Site dialog box, select HDLC Hub to change the TDM site to the HDLC site, as
shown in Figure 1.3. Click BSC Port. In the displayed dialog box, click YES. The Choice
Board&Port dialog box is displayed, as shown in Figure 1.4.
2015-3-9
Huawei Confidential
Page 79 of 129
INTERNAL
Set the parameters Dest SubRack No., Dest Slot No., and Dest Port No. to proper values
based on the GEHUB position. Then, click OK.
In the displayed dialog box, click OK to return to the Move Site dialog box, and then click
Next, as shown in Figure 1.5.
2015-3-9
Huawei Confidential
Page 80 of 129
INTERNAL
In the displayed Move Site dialog box, the original connection of the site and the connection
after the site is moved are available in the Move Site Result area. Ensure that the current
connection of the site is correct, and then click Finish, as shown in Figure 1.6.
Figure 1.6 Result of moving a site (1)
Click Continue, as shown in Figure 1.7. After the timeslots in the TDM site are arranged, a
message is displayed to prompt you to confirm the operation. Then, click OK.
2015-3-9
Huawei Confidential
Page 81 of 129
INTERNAL
Step 3 To complete the configuration of the lower-level site to the HDLC HUB site after the site is
moved, you need add the lower-level site by referring to 3.3.1 "Adding an HDLC HUB Site
on the BSC6000 LMT" after moving the BTS.
Step 4 Remove the E1 cable that connects the TDM site to the GEIUB. Then, insert the E1 cable into
the GEHUB in the BSC rack. (Remove the original E1 cable that connects the TDM site to
the GEIUB in the BSC rack, and then insert the cable into the corresponding port on the
GEHUB that is connected to the added HDLC site.) The OML is established after two
minutes and the RSL is established after five minutes.
Step 5 After the previous operations, the site still runs properly. The services processed on the site
are disrupted for about 18 to 20 minutes during the entire process.
----End
Method 2: Upgrade a TDM site on the existing network to an HDLC HUB site by
directly building an HDLC HUB site
To reduce the time of service interruption, you can upgrade a TDM site to an HDLC HUB site
as follows:
Configuring an HDLC HUB Site on the BSC6000 LMT > Preparing the E1 Line from the
BSC to the Site > Loading the Latest Version of the TMU > Loading the Latest Version of the
TRX > Activating the Latest Version of the TMU (Supporting the PTU) > Disconnecting the
Existing Network Cable from the TDM Site and Inserting the E1 Line into the Subrack
The operations for configuring the HDLC HUB site on the BSC6000 LMT are the same as
those for adding an HDLC HUB site. For details, see 3.3.1 "Adding an HDLC HUB Site on
the BSC6000 LMT."
The operations for configuring hardware and the transmission network are the same as those
for adding an HDLC HUB site. For details, see 3.3.1 "Adding an HDLC HUB Site on the
BSC6000 LMT."
2015-3-9
Huawei Confidential
Page 82 of 129
INTERNAL
Advantage
Port IP Address
Device IP Address
2015-3-9
Huawei Confidential
Page 83 of 129
INTERNAL
2015-3-9
Parameter
Configuration
4.4.4.4
255.255.255.0
Device IP address
GFGUB port
Port 5
Port IP address
12.13.11.10
12.13.11.11
255.255.255.0
12345678901234567890
TRX type
GRFU TRX
Huawei Confidential
Page 84 of 129
INTERNAL
When the BSC6000 communicates with the BTS through the device IP address or the port IP address,
the configurations on the BTS side are the same.
When the active and standby GFGUBs are used, a switch must be configured between the BSC and BTS
(that is, the ports with the same number on the active and standby GFGUBs are connected to the switch).
Generally, the data configuration is performed for the active board, and the BSC automatically backs up
the data to the standby board.
Step 1 Configure the device IP address (skip this step if you have set the device IP address of the
BSC). On the BSC6000 LMT, right-click a GFGUB board and choose Configure Device IP,
as shown in Figure 1.1.
Figure 1.1 Setting the device IP address
In the Configure Device IP dialog box, click Add. Set the logical IP address and the subnet
mask. Then, click OK, as shown in Figure 1.2.
2015-3-9
Huawei Confidential
Page 85 of 129
INTERNAL
Step 2 Set port IP addresses. On the BSC6000 LMT, right-click a GFGUB board and choose
Configure Ethernet Port Ip, as shown in Figure 1.1.
Figure 1.1 Setting port IP addresses
The Configure Ethernet Port IP dialog box is displayed, as shown in Figure 1.2.
2015-3-9
Huawei Confidential
Page 86 of 129
INTERNAL
Select a port that is not in use, for example, port 5. Set the port number, host IP address, and
subnet mask, and then click OK, as shown in Figure 1.3.
Figure 1.3 Setting the IP address for port 5
2015-3-9
Huawei Confidential
Page 87 of 129
INTERNAL
Step 3 Configure the router between the BSC and the BTS. For layer 2 networking, skip this step. On
the BSC6000 LMT, right-click the GFGUB board and choose Configure BSC router, as
shown in Figure 1.1.
Figure 1.1 Configuring a BSC router
The Configure BSC router dialog box is displayed, as shown in Figure 1.2.
2015-3-9
Huawei Confidential
Page 88 of 129
INTERNAL
In the Configure BSC Router dialog box, click Add to add a BSC router, as shown in Figure
1.3.
Figure 1.3 Adding a BSC router
The destination IP address of the route is the network segment where the IP address of the
BTS is located. The next hop is the IP address of the port of the router that is connected to the
2015-3-9
Huawei Confidential
Page 89 of 129
INTERNAL
BSC. The DHCP relay is configured on the router that is connected to the BTS and not
configured on the port of the BSC.
In layer 3 networking, the IP address and the subnet mask of the site should be changed to the
IP address and the subnet mask of the corresponding destination network segment.
Step 4 On the BSC6000 LMT, right-click a GFHUB and choose Add Site from the shortcut menu, as
shown in Figure 1.1.
Figure 1.1 Adding a site
Step 5 The Add Site dialog box is displayed, as shown in Figure 1.1. Click Add Site.
2015-3-9
Huawei Confidential
Page 90 of 129
INTERNAL
Step 6 In the Add New Site dialog box, set the parameters as required. Set Site Type to BTS3900
GSM to Service Mode to IP. Then, click OK to finish the configuration, as shown in Figure
1.1.
1.This dialog box may vary with different BSC versions, but the configuration process is the same.
2.The Cfg RFU by Slot check box is not selected when adding a new site. The future configuration
could be based on the RXU topological structure (for details, see Step 9).
2015-3-9
Huawei Confidential
Page 91 of 129
INTERNAL
The following describes the meanings of the parameters in the Add New Site dialog box.
Site IP and IP Mask: Currently, the BTS can communicate with the BSC through the IP
network. Therefore, Site IP and IP Mask should be set. In layer 2 networking mode, the
IP address of the BTS should be on the same network segment as that of port 5 on the
BSC.
Step 7 In the Add Site dialog box, click Next. In the Add Cell dialog box, click Add Cell, as shown
in Figure 1.1.
2015-3-9
Huawei Confidential
Page 92 of 129
INTERNAL
In the Add New Cell dialog box, set Cell Name and Frequency Band. Then click OK to
finish the configuration, as shown in Figure 1.2.
Figure 1.2 Add New Cell dialog box
Step 8 Return to the Add Site dialog box, and then click Next. In the Configure Site Attributes
dialog box, click Site Attributes, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 93 of 129
INTERNAL
Step 9 In the Site Device Attributes dialog box, right-click the icon
under RXU topological
structure. Choose Add RXU Chain from the shortcut menu, as shown in Figure 1.1.
Figure 1.1 Adding the RXU chain
In the Add RXU Chain dialog box, set Chain Type and Chain Head Board Port. Chain
Head Board Port is the port number of the SFP where the TRX is connected, that is, the
CPRI port; Chain Type can be Chain or Ring depending on actual scenarios. The chain or
ring here indicates the topological structure of the TRX. Then, click OK. Figure 1.2 takes
adding a chain on SFP 0 of the GTMU as an example.
2015-3-9
Huawei Confidential
Page 94 of 129
INTERNAL
Step 10 Return to the Site Device Attributes dialog box and right-click the added chain, and then
choose Add RXU > Add GRFU from the shortcut menu, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 95 of 129
INTERNAL
In the Add GRFU dialog box, set RXU NAME and RXU No., as shown in Figure 1.2. Then,
click OK.
Figure 1.2 Setting the RXU name and number
Step 11 Return to the Site Device Attributes dialog box and right-click the added RXU chain, and
then choose Binding logical TRX from the shortcut menu, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 96 of 129
INTERNAL
In the Binding logical TRX dialog box, select Trx No. and set Assigned Cell.
Select the logical TRX that you want to bind to the RXU board.
If you bind a logical TRX to the RXU board, you need to set a TRX number and select a
cell for it.
If you bind a GRRU logical TRX, you need to select a transmitting channel A or B.
Step 12 Right-click the added chain, and then choose Configure RXU Attribute from the shortcut
menu to set board attributes as planned, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
Page 97 of 129
INTERNAL
Step 13 If a new site board is to be cascaded with the GRFU, right-click the GRFU, and then choose
Add RXU > Add GRFU from the shortcut menu, as shown in Figure 1.1.
Figure 1.1 Adding a cascaded GRFU
2015-3-9
Huawei Confidential
Page 98 of 129
INTERNAL
To add a board over a different port, repeat Step 9 through Step 13. In RXU topological
structure, add all required RXU boards and logical TRXs. When you add cells in batches,
ensure that each cell is configured with at least one carrier.
Step 14 In the Site Device Attributes dialog box, right-click a GTMU board and choose Configure
Board Attributes, as shown in Figure 1.1.
Figure 1.1 Setting an electronic label
In the Basic Attributes of Site Board dialog box, click the IP Interface Board Parameter
of BTS tab. According to the bar code of the BBU, set BTS Interface Board Bar Code 1.
Then, click the FE port parameter of BTS tab to set port parameters. After you set the port
parameters, click OK, as shown in Figure 1.2 and Figure 1.3.
Figure 1.2 Setting a bar code of the electronic label
2015-3-9
Huawei Confidential
Page 99 of 129
INTERNAL
The current version supports only 100 Mbit/s full duplex. It does not support 10 Mbit/s full
duplex, 10 Mbit/s half duplex, or 100 Mbit/s half duplex.
Step 15 After you set the site attributes, in the Add Site dialog box, click Next. Then, click Cell
Attributes, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
INTERNAL
In the Set Cell Attributes dialog box, set the cell attributes as required, as shown in Figure
1.2.
Set parameters MCC, MNC, LAC, CI, NCC, and BCC to the same values as those on the
MSC side.
2015-3-9
Huawei Confidential
INTERNAL
In the Set Cell Attributes dialog box, double-click the TRX under Assigned TRXs or click
Frequency Config to configure required frequencies, as shown in Figure 1.3. In the Set Cell
Frequency dialog box, select the frequencies to be set, as shown in Figure 1.4.
2015-3-9
Huawei Confidential
INTERNAL
2015-3-9
Huawei Confidential
INTERNAL
When setting the frequencies of the GRFU, the bandwidth cannot exceed 15 MHz owing
to the limit of the frequency bandwidth. That is, there should be no greater than 75
frequencies between the highest frequency and the lowest frequency because the
difference between the two adjacent frequencies is 200 kbit/s.
When setting the frequencies of the GRRU, the bandwidth cannot exceed 12.5 MHz owing
to the limit of the frequency bandwidth. That is, there should be no greater than 62
frequencies between the highest frequency and the lowest frequency because the
difference between the two adjacent frequencies is 200 kbit/s.
There are no limitations for the frequencies of the DRRU and DRFU.
Return to the Set Cell Attributes dialog box (as shown in Figure 1.2) to set the frequency and
attributes of the TRXs.
2015-3-9
Click the Frequency Attributes tab page to set the TRX frequency, as shown in Figure
1.5.
Click the Channel Attributes tab page to set the channel attributes of the TRXs, as
shown in Figure 1.6.
Click the Device Attributes tab page to set the parameters such as Power Level,
Receive Mode, and Send Mode, as shown in Figure 1.7.
Huawei Confidential
INTERNAL
2015-3-9
Huawei Confidential
INTERNAL
2015-3-9
Huawei Confidential
INTERNAL
2015-3-9
Huawei Confidential
INTERNAL
2015-3-9
Huawei Confidential
INTERNAL
----End
2015-3-9
Huawei Confidential
INTERNAL
2015-3-9
Huawei Confidential
INTERNAL
----End
1.To ensure that the clock frequency output by the clock server is a standard reference source,
you must calibrate the clock server before using it.
2.The value of ShakeHandPeriodB must be greater than the values of ShakeHandPeriodA
and ShakeHandPeriodC.
2015-3-9
Huawei Confidential
INTERNAL
slot 20 and uses #5 upper-level port. (The numbering of ports starts with 0.) Therefore, you
should connect the sixth port of the GFGUB board from top down to the port of the IP site.
Check the continuity between the BSC and the BTS when the optical interface board of
the BSC is used.
The optical signals from the optical interface board of the BSC can be accessed to the
optical transmission network of the customer in two modes: direct access or access
through optical switching. As the BTS3900 does not support an optical transmission
connection currently, there must be an optical and electrical switch on the BTS side.
To check whether the transmission link is normal, do as follows:
(1) Connect a PC to the switch that is accessed by the BTS.
(2) Ping the interface board of the BSC.
(3) Ping the PC on the BSC.
If the preceding ping operations are successful, it indicates that two interfaces of the
BSC and the BTS on the transmission network can communicate with each other. If a
link cannot be set up on the site, you need to check the BSC configuration, physical
connections of the BTS, and board status. You can capture packets on the switch on the
BTS side and feed them back to the R&D personnel for analysis.
2015-3-9
Huawei Confidential
INTERNAL
If the ping operations are failed, you can add a switch on the BSC side and connect a PC
to the switch. Then, ping the PCs on the BTS side and the BSC side. If the ping
operation is successful, you need to check the physical connections of the BSC. If the
ping operation is still failed, you can request the network engineer of the customer to
check whether the transmission network properly allocates resources.
Check the continuity between the BSC and the BTS when the electrical interface board
of the BSC is used.
The check method is basically the same as that for the optical transmission.
Note: If the transmission network is abnormal, an optical and electrical switch may be
required so that a PC is connected to the switch for pinging and packet capturing.
The transmission network is very complex and may contain NEs of multiple vendors.
Currently, there is no effective and accurate location method for a transmission link fault.
In practice, if the transmission link is faulty, you can only perform loopback tests for the
entire transmission network section by section to find faulty nodes.
The IP functions of the BTS3900 are supported in V100R008 and later versions. If the current
version does not support the IP functions, you must upgrade the current version to the version that
supports the IP functions in TDM mode.
If the BSC corresponding to the TDM site and the BSC corresponding to the target IP site are
located in different places, method 1 cannot be used because that different BSC racks are involved.
In this case, only method 2 can be used.
Generally, the BTS and BSC are placed in different places. For convenient construction, the upgrade
procedure consists of the operations on the BTS side and those on the BSC side. The operations on
the BTS side are mainly to connect network cables. The operations on the BSC side are to upgrade
the software version of the BTS on the BSC6000 LMT, configure the BSC GFGUB and
corresponding ports, and move the BTS on the BSC6000 LMT.
If an external PCU is configured for GPRS services in a cell under the TDM site, you must disable
the GPRS services under the site. Otherwise, the configuration for site movement fails.
Method 1: Upgrade a TDM site on the existing network to an IP site by the site
movement function
Step 1 Select the GFGUB of the BSC corresponding to the target IP site and the available port of the
GFGUB, and then configure related IP addresses for the BSC. For details, see Step 1 through
Step 3 in 3.4.2 "Adding an IP Site on the BSC6000 LMT."
Step 2 Connect the transmission cable between the BSC and the BTS (for details, see 3.4.4
"Configuring Hardware and the Transmission Network").
2015-3-9
Huawei Confidential
INTERNAL
Step 3 Right-click the TDM site to be upgraded and choose Site Operation > Configure Site
Attributes from the shortcut menu. Then, set CRC4 Check Switch to ON on the Basic
Information tab page in the displayed Site Attributes dialog box, as shown in Figure 1.1.
Figure 1.1 Setting the CRC4 check switch
Step 4 Deactivate the TDM site (optional). Right-click the TDM site to be upgraded and choose Site
Operation > Set Site Active State from the shortcut menu. Then, set Site Active State to Not
Activated.
After the TDM site is deactivated, the operations in Step 6 cannot be performed because that the
operation time of the IP site is long.
2015-3-9
Huawei Confidential
INTERNAL
2015-3-9
Huawei Confidential
INTERNAL
In the Move Site dialog box, select the target site from the Site View area, and then click
Move Site, as shown in Figure 1.2.
2015-3-9
Huawei Confidential
INTERNAL
In the Move Site dialog box, select IP to change the TDM site to the IP site, as shown in
Figure 1.3.Click BSC Port. In the displayed dialog box, click YES. The Choice Board&Port
dialog box is displayed, as shown in Figure 1.4.
2015-3-9
Huawei Confidential
INTERNAL
Set the parameters Dest SubRack No., Dest Slot No., and Dest Port No. to proper values
based on the GFGUB position. Then, click OK.
In the displayed dialog box, click OK to return to the Move Site dialog box, and then click
Next, as shown in Figure 1.5.
The bar code of the BBU and the IP information of the site are not configured when the site is
moved. In this case, a dialog box is displayed, prompting you to confirm the settings. You can
click OK to ignore this message. (The attributes of the BBU are separately configured after
the site is moved.)
2015-3-9
Huawei Confidential
INTERNAL
In the displayed Move Site dialog box, the original connection of the site and the connection
after the site is moved are available in the Move Site Result area. Ensure that the current
connection of the site is correct, and then click Finish, as shown in Figure 1.6.
Figure 1.6 Result of moving a site (1)
Click Continue, as shown in Figure 1.7. After the timeslots in the TDM site are arranged, a
message is displayed to prompt you to confirm the operation. Then, click OK.
2015-3-9
Huawei Confidential
INTERNAL
2015-3-9
Huawei Confidential
INTERNAL
Step 3 Reset the site so that the site works in probe state to reduce the interruption duration
(optional).
Step 4 On the BSC6000 LMT, right-click the IP site to be switched in the navigation tree, and then
choose Site Operation > Move Site from the shortcut menu, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
INTERNAL
Step 5 In the Move Site dialog box, select the target site from the Site View area, and then click
Move Site, as shown in Figure 1.1.
Figure 1.1 Moving a site (2)
Step 6 In the Move Site dialog box, select TDM to change the IP site to the TDM site, as shown in
Figure 1.1.Click BSC Port. In the displayed dialog box, click YES. The Choice Board&Port
dialog box is displayed, as shown in Figure 1.2.Set the parameters Dest SubRack No., Dest
Slot No., and Dest Port No. to proper values based on the GEIUB position. Then, click OK.
2015-3-9
Huawei Confidential
INTERNAL
Step 7 In the displayed dialog box, click OK to return to the Move Site dialog box, and then click
Next, as shown in Figure 1.1.
2015-3-9
Huawei Confidential
INTERNAL
Step 8 In the displayed Move Site dialog box, the original connection of the site and the connection
after the site is moved are available in the Move Site Result area. Ensure that the current
connection of the site is correct, and then click Finish. After the timeslots in the TDM site are
arranged, a message is displayed to prompt you to confirm the operation. Then, click OK.
Check the operation status of the site 20 minutes after the operations are complete.
----End
2015-3-9
Huawei Confidential
INTERNAL
2015-3-9
Huawei Confidential
INTERNAL
Troubleshooting
Huawei Confidential
INTERNAL
3. Check whether the bar code for the site is correct. For details, see 3.4.2 "Adding an IP Site
on the BSC6000 LMT."
Step 3 Check the LEDs on the TMU board for alarms.
If the problem still persists, check the LEDs on the TMU board and view the related alarm
information. (For details, see 6.1 "LEDs on the TMU Board.") Then, correct the problem
according to the solution to the alarm.
----End
5.2 FAQ
5.2.1 IP Site Problems
Problem Description
After an IP site is set up, it does not work for a long time.
Network management software indicates that the port of the optical transceiver for the IP site
is not connected.
Cause Analysis
The network cable between the optical transceiver and the IP site is probably faulty.
Solution
Take a new network cable and tools to the site. The on-site survey indicates that the
construction teams failed to prepare a quality network cable. Replace the existing network
cable with a new one. The connection is normal.
Cause Analysis
A check on the BSC6000 LMT indicates that the HDLC site is attached to port 4 of the BSC
PIU board whereas the E1 line is inserted to port 5 of the PIU board.
Solution
Insert the E1 line to port 4.
2015-3-9
Huawei Confidential
INTERNAL
Appendix
Color
Status
Description
RUN
Green
ON
Green
OFF
Green
Green
Green
Red
ON
OFF
No fault occurs.
ON
OFF
ON
OFF
Green
ON
Red
ON
ALM
ACT
LIU0-LIU3
CPRI0-CPRI5
2015-3-9
Green
Green
Huawei Confidential
INTERNAL
6.2 References