TWIN SCREW PUMP DATA SHEET

Applicable to
FOR
SITE
SERVICE

Proposal / Purchase / As Built


BLACK OIL FACILITY
UNIT
-BIHTA DEPOT
NO. OF PUMPS
3
WAGON UNLOADING
TYPE
TWIN SCREW
PUMPS
MANUFACTURER
*
SERIAL NO.
PARALLEL OPNS
YES
APPICABLE STD
API 676
GENERAL
1
PUMP ITEM NO
MOTOR MAKE
*
MOTOR DATA SHEET NO
*
GEAR MAKE
*
OPERATING CONDITIONS
LIQUID
CAPACITY (LPM)
5500
LIQUID HANDLED
FURNACE OIL
DIFF HEAD (M)
45M
PUMPING TEMP
20 DEG
DIFF PRESS(KG/CM2)
4.5
SPECIFIC GRAVITY
0.9369
NPSHa (M)
5.0
MAX /MIN TEMP(degC) 48 / 20
RV SET PRESS(KG/CM2)
6.0
VISCOSITY (MIN/MAX) 180 cST/1000 cST
LIQUID
TOXIC &
FLAMMABLE
PERFORMANCE
SITE DATA
RATED CAPACITY (LPM)
*
LOCATION
OUTDOOR/UNDER
ROOF
NPSH REQUIRED (M)
*
ELECTRICAL CLASS
GR.A/B DIV II
RATED SPEED
*
AMB TEMP RANGE
5 DEG 48 DEG
DISPLACEMENT (LPM)
*
OTHER CONDITIONS DUST
VOLUMETRIC EFF.
*
UTILITY CONDITION
3PH/415V/50Hz
MECHANICAL EFF.
*
HEAT TRACING
NO
OVERALL EFF.
*
KW AT MAX VISCOSITY
*
KW AT RV SETTING
*
CONSTRUCTION
CONNECTIONS
SIZE/RATING
FACING
POSITION
I) SUCTION
*
*
*
II) DISCHARGE
*
*
*
III) GLAND FLUSH
*
*
*
IV) DRAINS
*
*
*
V) VENTS
*
*
*
CASING
MATERIALS
I)MAWP (KG/CM2)
*
CASING
CS ASTM A 216 Gr.
WCB
II)HYDROTEST PRESS
*
SHAFT & SCREW
AISI 410 (INTEGRAL)
(KG/CM2)
TIMING GEAR
*
TIMING GEARS
EN 353 / BS 970
LUBRICATION TYPE
*
RV BODY
CS ASTM A 216 Gr.
WCB
LUBRICANT TYPE
*
RV INTERNAL
SS
MECH SEAL
DURA/EAGLE/
RV MAKE
Mekaster / Tyco /
MANUFACTURER
FLOWSERVE
Fainger Leser
MODEL AND CODE
*
COUPLING GUARD
NON SPARKING (AL)
DRIVE MECHANISM
LINER
CI IS 210 FG 260
DIRECT COUPLING
FLEXIBLE
WEIGHT Pump/Motor
*
METALLIC SPACER

DRIVERS
MOTOR MAKE AS PER *( Kirloskar / ABB/ GEC
IS-325
/Siemens/ Bharat Bijlee/
Greaves)
TYPE
FRAME NO
SPEED
KW
VOLTS
PHASE
Hz
PROTECTION
ENCLOSURE

MOTOR RATING
INSULATION
STARTING METHOD
MOUNTING
TERMINAL BOX

EARTHING
Painting
Inspection Notes

Documentation

Commissioning
Assistance
Additional Comments

SC INDUCTION MOTOR
*
*(MAX 1500 RPM)
*
415 +/- 10%
3
50 +/- 5%
TEFC IP-55 (IS:4691)
FLP (as per IS 2148
suitable for Class II,
Div I for Group IIA & IIB
gases
125%
OF
RATED
CAPACITY
CLASS F
STAR-DELTA
HORIZONTAL
FOOT
MOUNTED
IP 55 WITH CABLE
ENTRY
FOR
SP.
HEATER/ 2 RUNS OF
POWER CABLES WITH
DC FLP GLAND
2 NOS BOLTED TYPE

QA INSPECTION AND TEST


THIRD PARTY
DNV/BV/IRS/CEIL
AGENCY FOR MTC
REVIEW &
WITNESSING
INSPECTION
AS PER APPVD QAP
MANDATORY TEST
PUMP
PROCEDURES
AS PER API 576
HYDROSTEST
WITNESSING
PERFORMANCE
WITNESSING
NPSH
WITNESSING
SCREW
DYNAMIC BALANCING
MOTOR

TYPE TEST CERT


REVIEW
INSULATION
RESISTANCE
HIGH VOLTAGE
NO LOAD RUNNING
LOCKED ROTOR
TEST

YES (IS-325)
AS PER IS-325/4029
AS PER IS-325/4029
AS PER IS-325/4029
AS PER IS-325/4029

REDUCED VOLT
AS PER IS-325/4029
RUNNING UP TEST
All pumps shall be painted with two coats of anti corrosive paint and three
coats with glossy finish as per the approved colour code.
Inspection Note, MTC and Type Test Certificate to be certified by TPIA before
Despatch. Acceptance of shop tests does shall not relieve the vendor of his
responsibilities whatsoever.
a. PERFORMANCE CURVES shall indicate efficiency, NPSHr and BHP as
functions of Head at various speeds and viscosities.
b. PRELIMINARY Outline & Arrangement drawings, schematic diagrams.
c. CROSS SECTIONAL DRAWING and literature (TWO sets of each pump)
d. Drawings for Installation
e Drawings showing dimensions and position of mechanical seal.
f Foundation plan.
g. Outline dimensional drawing with general arrangement.
h. Manual for Installation /operating /maintenance and overhauling.
i. Spare Parts book
Required. Refer Terms and Conditions
Matching flange for Suction and discharge to be supplied by the vendor along
with the pump. FLP Cable glands/plugs to be supplied with Terminal Box

TWIN SCREW PUMP DATA SHEET


Applicable to
FOR
SITE
SERVICE

Proposal / Purchase / As Built


BLACK OIL FACILITY
UNIT
-BIHTA DEPOT
NO. OF PUMPS
2
TANK TRUCK LOADING
TYPE
TWIN SCREW
PUMPS
MANUFACTURER
*
SERIAL NO.
PARALLEL OPNS
YES
APPICABLE STD
API 676
GENERAL
PUMP ITEM NO
2
MOTOR MAKE
*
MOTOR DATA SHEET NO
*
GEAR MAKE
*
OPERATING CONDITIONS
LIQUID
CAPACITY (LPM)
1200
LIQUID HANDLED
FURNACE OIL
DIFF HEAD (M)
40M
PUMPING TEMP
20 DEG
DIFF PRESS(KG/CM2)
4.0
SPECIFIC GRAVITY
0.9369
NPSHa (M)
5.0
MAX /MIN TEMP(degC) 45 / 20
RV SET PRESS(KG/CM2)
5.5
VISCOSITY (MIN/MAX) 180 cST/1000 cST
LIQUID
TOXIC &
FLAMMABLE
PERFORMANCE
SITE DATA
RATED CAPACITY (LPM)
*
LOCATION
OUTDOOR/UNDER
ROOF
NPSH REQUIRED (M)
*
ELECTRICAL CLASS
GR.A/B DIV II
RATED SPEED
*
AMB TEMP RANGE
5 DEG 48 DEG
DISPLACEMENT (LPM)
*
OTHER CONDITIONS DUST
VOLUMETRIC EFF.
*
UTILITY CONDITION
3PH/415V/50Hz
MECHANICAL EFF.
*
HEAT TRACING
NO
OVERALL EFF.
*
KW AT MAX VISCOSITY
*
KW AT RV SETTING
*
CONSTRUCTION
CONNECTIONS
SIZE/RATING
FACING
POSITION
I) SUCTION
*
*
*
II) DISCHARGE
*
*
*
III) GLAND FLUSH
*
*
*
IV) DRAINS
*
*
*
V) VENTS
*
*
*
CASING
MATERIALS
I)MAWP (KG/CM2)
*
CASING
CS ASTM A 216 Gr.
WCB
II)HYDROTEST PRESS
*
SHAFT & SCREW
AISI 410 (INTEGRAL)
(KG/CM2)
TIMING GEAR
*
TIMING GEARS
EN 353 / BS 970
LUBRICATION TYPE
*
RV BODY
CS ASTM A 216 Gr.
WCB
LUBRICANT TYPE
*
RV INTERNAL
SS
MECH SEAL
DURA/EAGLE/
RV MAKE
Mekaster / Tyco /
MANUFACTURER
FLOWSERVE
Fainger Leser
MODEL AND CODE
*
COUPLING GUARD
NON SPARKING (AL)
DRIVE MECHANISM
LINER
CI IS 210 FG 260
DIRECT COUPLING
FLEXIBLE
WEIGHT Pump/Motor
*
METALLIC SPACER

DRIVERS
MOTOR MAKE AS PER *( Kirloskar / ABB/ GEC
IS-325
/Siemens/ Bharat Bijlee/
Greaves)
TYPE
FRAME NO
SPEED
KW
VOLTS
PHASE
Hz
PROTECTION
ENCLOSURE

MOTOR RATING
INSULATION
STARTING METHOD
MOUNTING
TERMINAL BOX

EARTHING
Painting
Inspection Notes

Documentation

Commissioning
Assistance
Additional Comments

SC INDUCTION MOTOR
*
*(MAX 1500 RPM)
*
415 +/- 10%
3
50 +/- 5%
TEFC IP-55 (IS:4691)
FLP (as per IS 2148
suitable for Class II,
Div I for Group IIA & IIB
gases
125%
OF
RATED
CAPACITY
CLASS F
STAR-DELTA
HORIZONTAL
FOOT
MOUNTED
IP 55 WITH CABLE
ENTRY
FOR
SP.
HEATER/ 2 RUNS OF
POWER CABLES WITH
DC FLP GLAND
2 NOS BOLTED TYPE

QA INSPECTION AND TEST


THIRD PARTY
DNV/BV/IRS/CEIL
AGENCY FOR MTC
REVIEW &
WITNESSING
INSPECTION
AS PER APPVD QAP
MANDATORY TEST
PUMP
PROCEDURES
AS PER API 576
HYDROSTEST
WITNESSING
PERFORMANCE
WITNESSING
NPSH
WITNESSING
SCREW
DYNAMIC BALANCING
MOTOR

TYPE TEST CERT


REVIEW
INSULATION
RESISTANCE
HIGH VOLTAGE
NO LOAD RUNNING
LOCKED ROTOR
TEST

YES (IS-325)
AS PER IS-325/4029
AS PER IS-325/4029
AS PER IS-325/4029
AS PER IS-325/4029

REDUCED VOLT
AS PER IS-325/4029
RUNNING UP TEST
All pumps shall be painted with two coats of anti corrosive paint and three
coats with glossy finish as per the approved colour code.
Inspection Note, MTC and Type Test Certificate to be certified by TPIA before
Despatch. Acceptance of shop tests does shall not relieve the vendor of his
responsibilities whatsoever.
a. PERFORMANCE CURVES shall indicate efficiency, NPSHr and BHP as
functions of Head at various speeds and viscosities.
b. PRELIMINARY Outline & Arrangement drawings, schematic diagrams.
c. CROSS SECTIONAL DRAWING and literature (TWO sets of each pump)
d. Drawings for Installation
e Drawings showing dimensions and position of mechanical seal.
f Foundation plan.
g. Outline dimensional drawing with general arrangement.
h. Manual for Installation /operating /maintenance and overhauling.
i. Spare Parts book
Required. Refer Terms and Conditions
Matching flange for Suction and discharge to be supplied by the vendor along
with the pump. FLP Cable glands/plugs to be supplied with Terminal Box

TWIN SCREW PUMP DATA SHEET


Applicable to
FOR
SITE
SERVICE
MANUFACTURER
PARALLEL OPNS

Proposal / Purchase / As Built


BLACK OIL FACILITY
UNIT
-BIHTA DEPOT
NO. OF PUMPS 3
Tank Truck Loading/ Unloading
TYPE
TWIN SCREW
*
SERIAL NO.
YES
APPICABLE
API 676
STD
GENERAL
PUMP ITEM NO
3
MOTOR MAKE
*
MOTOR DATA SHEET NO
*
GEAR MAKE
*
OPERATING CONDITIONS
LIQUID
CAPACITY (LPM)
1200
LIQUID HANDLED
BITUMEN 60/70 &
80/100 GRADE
DIFF HEAD (M)
40M
PUMPING TEMP
135 DEG
DIFF PRESS(KG/CM2)
4.0
SPECIFIC GRAVITY
1.035
NPSHa (M)
5.0
DESIGN TEMP (DegC) 175
RV SET PRESS(KG/CM2)
5.5
VISCOSITY (MIN/MAX) 258/517 cST
LIQUID
TOXIC & FLAMMABLE
PERFORMANCE
SITE DATA
RATED CAPACITY (LPM)
*
LOCATION
OUTDOOR/UNDER
ROOF
NPSH REQUIRED (M)
*
ELECTRICAL CLASS
GR.A/B DIV II
RATED SPEED
*
AMB TEMP RANGE
5 DEG 48 DEG
DISPLACEMENT (LPM)
*
OTHER CONDITIONS DUST
VOLUMETRIC EFF.
*
UTILITY CONDITION
3PH/415V/50Hz
MECHANICAL EFF.
*
HEAT TRACING
YES
OVERALL EFF.
*
KW AT MAX VISCOSITY
*
KW AT RV SETTING
*
CONSTRUCTION
CONNECTIONS
SIZE/RATING
FACING
POSITION
I) SUCTION
*
*
*
II) DISCHARGE
*
*
*
III) GLAND FLUSH
*
*
*
IV) DRAINS
*
*
*
V) VENTS
*
*
*
CASING
MATERIALS
I)MAWP (KG/CM2)
*
CASING
CS ASTM A 216 Gr.
WCB
II)HYDROTEST PRESS
*
SHAFT & SCREW
AISI 410 (INTEGRAL)
(KG/CM2)
TIMING GEAR
*
TIMING GEARS
EN 353 / BS 970
LUBRICATION TYPE
*
RV BODY
CS ASTM A 216 Gr.
WCB
LUBRICANT TYPE
*
RV INTERNAL
SS
MECH SEAL
DURA/EAGLE/
RV MAKE
Mekaster / Tyco / Fainger
MANUFACTURER
FLOWSERVE
Leser
MODEL AND CODE
*
COUPLING GUARD
NON SPARKING (AL)
DRIVE MECHANISM
LINER
CI IS 210 FG 260
DIRECT COUPLING
FLEXIBLE
WEIGHT Pump/Motor *
METALLIC SPACER

DRIVERS
MOTOR MAKE AS PER *( Kirloskar / ABB/ GEC
IS-325
/Siemens/ Bharat Bijlee/
Greaves)
TYPE
FRAME NO
SPEED
KW
VOLTS
PHASE
Hz
PROTECTION
ENCLOSURE

MOTOR RATING
INSULATION
STARTING METHOD
MOUNTING
TERMINAL BOX

EARTHING
Painting
Inspection Notes

Documentation

Commissioning
Assistance
Additional Comments

SC INDUCTION MOTOR
*
*(MAX 1500 RPM)
*
415 +/- 10%
3
50 +/- 5%
TEFC IP-55 (IS:4691)
FLP (as per IS 2148
suitable for Class II,
Div I for Group IIA & IIB
gases
125%
OF
RATED
CAPACITY
CLASS F
STAR-DELTA
HORIZONTAL
FOOT
MOUNTED
IP 55 WITH CABLE
ENTRY
FOR
SP.
HEATER/ 2 RUNS OF
POWER CABLES WITH
DC FLP GLAND
2 NOS BOLTED TYPE

QA INSPECTION AND TEST


THIRD PARTY
DNV/BV/IRS/CEIL
AGENCY FOR MTC
REVIEW &
WITNESSING
INSPECTION
AS PER APPVD QAP
MANDATORY TEST
PUMP
PROCEDURES
AS PER API 576
HYDROSTEST
WITNESSING
PERFORMANCE
WITNESSING
NPSH
WITNESSING
SCREW
DYNAMIC BALANCING
MOTOR

TYPE TEST CERT


REVIEW
INSULATION
RESISTANCE
HIGH VOLTAGE
NO LOAD RUNNING
LOCKED ROTOR
TEST

YES (IS-325)
AS PER IS-325/4029
AS PER IS-325/4029
AS PER IS-325/4029
AS PER IS-325/4029

REDUCED VOLT
AS PER IS-325/4029
RUNNING UP TEST
All pumps shall be painted with two coats of anti corrosive paint and three
coats with glossy finish as per the approved colour code.
Inspection Note, MTC and Type Test Certificate to be certified by TPIA before
Despatch. Acceptance of shop tests does shall not relieve the vendor of his
responsibilities whatsoever.
a. PERFORMANCE CURVES shall indicate efficiency, NPSHr and BHP as
functions of Head at various speeds and viscosities.
b. PRELIMINARY Outline & Arrangement drawings, schematic diagrams.
c. CROSS SECTIONAL DRAWING and literature (TWO sets of each pump)
d. Drawings for Installation
e Drawings showing dimensions and position of mechanical seal.
f Foundation plan.
g. Outline dimensional drawing with general arrangement.
h. Manual for Installation /operating /maintenance and overhauling.
i. Spare Parts book
Required. Refer Terms and Conditions
Matching flange for Suction and discharge to be supplied by the vendor along
with the pump. FLP Cable glands/plugs to be supplied with Terminal Box