Anda di halaman 1dari 7

Code: LLM18-QP-04.

14/FU
Rev.: 0
Date :
Total Page: 1

FIT-UP DIMENSIONAL INSPECTION


REPORT
Report No.: FU-007
Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-FU-007 (attached)

Item: TAPPING AREA LOCAL SUCTION DUCT

Drawing No.: AJ-2431-Z30-012

No.

Location

Drawing Dim.

Actual Dim.

Deviation

Tolerance

L1

1200

L2

2850

L3

1325

L4

2850

L5

1325

L6

2803

L7

2803

L8

1400

Result

Note: Application standard EN ISO 13920:1996 class B.


Measurement implement: Metal tape.
LILAMA 18
Prepared

VKS

Inspected/Reviewed

Reviewed/Approved

Sign:

Sign:

Name:

Name:
Page 1/7

Remarks

FIT-UP DIMENSIONAL INSPECTION


REPORT
Report No.: FU-007

Code: LLM18-QP-04.14/FU
Rev.: 0
Date :
Total Page: 1

Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-FU-007 (attached)

Item: TAPPING AREA LOCAL SUCTION DUCT

Drawing No.: AJ-2431-Z30-012

No.
Date:

Location

Drawing Dim.

Actual Dim.

Deviation
Date:

Page 2/7

Tolerance

Result

Remarks

Code: LLM18-QP-04.14/DI
Rev.: 0
Date:
Total Page: 1

FINAL DIMENSIONAL INSPECTION


REPORT
Report No.:DI - 007
Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-DI-007 (attached)

Item: TAPPING AREA LOCAL SUCTION DUCT

Drawing No.: AJ-2431-Z30-012

No.

Location

Drawing Dim.

Actual Dim.

Deviation

Tolerance

L1

1200

L2

2850

L3

1325

L4

2850

L5

1325

L6

2803

L7

2803

L8

1400

Result

Note: Application standard EN ISO 13920:1996 class B.


Measurement implement: Metal tape.
LILAMA 18
Prepared

VKS

Inspected/Reviewed

Reviewed/Approved

Sign:

Sign:

Name:

Name:

Page 3/7

Remarks

FINAL DIMENSIONAL INSPECTION


REPORT
Report No.:DI - 007

Code: LLM18-QP-04.14/DI
Rev.: 0
Date:
Total Page: 1

Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Sketch: VKS-LM18-DI-007 (attached)

Item: TAPPING AREA LOCAL SUCTION DUCT

Drawing No.: AJ-2431-Z30-012

No.
Date:

Location

Drawing Dim.

Actual Dim.

Deviation
Date:

Page 4/7

Tolerance

Result

Remarks

Code: LLM18-QP-04.14/VI

VISUAL INSPECTION RECORD


Record No.: VI-007

Rev: 0
Date:
Total page: 2

Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Drawing No.: AJ-2431-Z30-012

Item: TAPPING AREA LOCAL SUCTION DUCT

Weld joint: AJ-2431-Z30-012-J1..J8 (att.)

Test & Inspection


procedure

Item
No.
A

VISUAL CHECK FOR WELD


Fillet weld (leg length or throat
depth)

Acceptance criteria

Intermittent weld
a) Intermittent pitch
b) Weld length

Linear misalignment in
butt weld

Leg length and throat depth shall not be


less than design dimensions on drawing.
When not specified on drawing, throat
depth shall be minimum 0.7t. Where t:
thickness of a thinner plate at welded
plates.
Intermittent pitch shall be between +/-10
mm of design values on drawing.
Weld length shall be between -5 and +10
mm of design values on drawing.
Linear misalignment shall be not excess
10% of plate thickness at welds, but
maximum 3.0mm.

Unevenness in bead surface


Depth D shall be 2 mm or less for
50mm long weld.

4
Irregularity in bead width
5

Difference in bead widths (a - b) shall be


5 mm
or less for 50 mm long weld.
a b < 3 mm

Overlap
Overlap shall be 1.5 mm. or less per 100
mm long in bead direction.

6
Undercut

Depth of undercut shall be 1.0 mm or


less.

7
Crater treatment
8

Craters shall have been treated.

Pit

No pits shall exist.

10

Slag inclusion

No included slag shall exist.

11

Crack

No cracks shall exist.

12

Spatter

Spatters shall be removed.

Acc.

Rej.

Remark

Code: LLM18-QP-04.14/VI

VISUAL INSPECTION RECORD

Rev: 0
Date:
Total page: 2

Record No.: VI-007


Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Drawing No.: AJ-2431-Z30-012

Item: TAPPING AREA LOCAL SUCTION DUCT

Weld joint: AJ-2431-Z30-012-J1..J8 (att.)

Item
No.

Test & Inspection


procedure

Acceptance criteria

Acc.

Accepted

Conclusion
B

VISUAL CHECK FOR SHAPE/SIZE

Contused wound, hammer


wound, irregularity, etc.

These wounds shall be ground for


inconspicuous and smooth surfaces.

Finished conditions after


removing temporary jigs used
during manufacture.

Smoothing shall reach the base


metal. Concave portions shall
be repaired

Contamination, stuck foreign


Cleaning has been done. No foreign
materials, and foreign materials
materials shall exist.
left in equipment.

Inclination, bend and deflection.

These defects shall not been visually


detected.

Matching marks:
1) Orientation marks
(00,900,1800,2700)
2) Center line mark

Marking shall be made.

Finished conditions at convex


and corner portions (for lined
products).

Finish shall be smooth (min. 2R).

Finished conditions at concave


and corner portions (for lined Finish shall be smooth (min. 5R).
products).

Corners in bolt holes mounting


strainers for water collecting
plates, lining attaching internal Parts to be lined shall have corners
parts, external surfaces of
chamfered (min. 1C).
flanges, and bolt holes in
flanges.
Conclusion
LILAMA 18
Prepared/Inspected

Sign

Inspected/Reviewed

Accepted

Rej.

Rejected

Rejected

VKS
Reviewed/Approved

Remark

Code: LLM18-QP-04.14/VI

VISUAL INSPECTION RECORD


Record No.: VI-007

Rev: 0
Date:
Total page: 2

Client: VINA KYOEI STEEL LTD.

Job No.: LLM18-QP-04.14

Project: VINA KYOEI EXPANSION PLAN

Drawing No.: AJ-2431-Z30-012

Item: TAPPING AREA LOCAL SUCTION DUCT

Weld joint: AJ-2431-Z30-012-J1..J8 (att.)

Item
No.
Name:
Date:

Test & Inspection


procedure

Acceptance criteria

Acc.

Rej.

Remark

Anda mungkin juga menyukai