Document No. : DEMO-U2-UDS-13 Rev.0

SPECIFICATION
a)

b)

c)

Installation Site
1) Location
:
Rayong, Thailand
2) Jurisdictional authority
:
3) Environmental conditions
i)
Wind design loads including relevant factors
:
ii)
Earthquake design loads
:
iii) Snow loads
:
iiii) Lowest one day mean temperature for location
:

Need not consider


No
No
No

Vessel identification
1) Vessel number or identification
2) Service fluid
i)
Proprietary fluids specific properties
ii)
Specific gravity

:
:
:
:

SD-001
Steam
N/A
N/A

:
:

Yes
Horizontal

Vessel configuration and controlling dimension


1) Outline drawings
2) Type of vessel
3) Opening
Reference line for bottom TL.
Mark
Q'ty
Size
1
DN 600
M1
DN 50
1
N1
DN 150
1
N2
1
N3
DN 50
DN 80
1
N4
4)
5)

d)

e)

Volume
Support

:
:

Flange type
HB. RF. Class 600
LWN. RF. Class 600
LWN. RF. Class 600
LWN. RF. Class 600
LWN. RF. Class 600
6.66
Skirt

No

Service
MANHOLE
STEAM INLET
STEAM OUTLET
DRAIN
SAFETY VALVE

m3

Design conditions
1) Design pressure at the top of the vessel
2) Design temperature
3) Minimum Design Metal Temperature (MDMT)
4) Dead load, live load

:
:
:
:

5,000
250
0
Yes

Operating conditions
1) Operation pressure
2) Operation temperation
3) Fluid transients and flow and sufficient properties

:
:
:

2500-4000
C
200
N/A

kPa (g)
C
C

(exclude static head)

kPa (g)

f)

Design fatigue life


Based on expirience with comparable equipment operating under similar condition, a Fatigue Analysis is not
not required in accordance with paragraph 5.5.2.2

g)

Material of construction
1) Materials
Shell / Head
Nozzle Pipe
Flange
Support
Stus bolt / Nut
2) Corrosion and/or erosion allowance

:
:
:
:
:
:

SA-516 M 485
SA-105M
SA-105M
SA-516 M 485
SA-193M Gr.B7 / SA-194M Gr.2H
3
mm

Page

3 of 4

Document No. : DEMO-U2-UDS-13 Rev.0


h)

Loads and Load cases


Yes No

Internal allowable working pressure


External allowable working pressure

Weight of vessel
Weight of vessel contents under operating and test conditions
Refractory linings, insulation
Static reactions from the weight of attached equipment, such as motors, machinery.
Appurtenance live loading.
Effect of fluid flow
Earthquake loads
Wind loads
Snow loads

i)

Overpressure protection
1) Pressure relief valve is the responsibility of the user. It will be installed on the piping system.
2) Jurisdictional acceptance is not required prior to operating of the vessel.

Additional Requirements
a)
b)
c)
d)
e)
f)
g)
h)

Additional requirements such as non-destructive examination,


restricted chemistry, or heat treatments
Type of weld joints and extent of required non-destructive examinations
Non-mandatory or optional provisions of this division that are considered
to be mandatory for the subject vessel
Any special requirement for marking and their location
Requirements for seals and/or bolting for closures and covers
Additional requirements relating to erection loadings
Any agreements which resolve the problems of operation
and maintenance control unique to the particular pressure vessel.
Specific additional requirements relating to pressure testing such as:
1) Fluid properties and test temperature limits
2) Position of vessel and support/foundation adequacy
if field hydrostatic testing is required
3) Location: Manufacturer's facility or on-site
4) Cleaning and drying
5) Selection of pressure test method
6) Application of paints, coatings and linings for all external steel surface

:
:

N/A
N/A

:
:
:
:

N/A
N/A
N/A
N/A

N/A

N/A

:
:
:
:
:

N/A
Rayong, Thailand
N/A
Hydrostatic Testing