Anda di halaman 1dari 38

A

Katalog
Catalogue
01 04 09 04

Energetski
srednjenaponski
kabeli s XLPE
izolacijom za
napone do 36 kV
Medium voltage
power cables
with XLPE insulation
for rated voltage
up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

SADR@AJ:

Medium voltage power cables for rated voltage up to 36 kV

ELECTRIC

CABLE

WORKS

CONTENTS:

page:

stranica:
1. UVOD

1. GENERAL

2. PRIMJENJENI STANDARDI

2. APPLIED STANDARDS

3. OZNA^IVANJE KABELA

3. CABLE DESIGNATION

4. KONSTRUKCIJA KABELA

4. CABLE DESIGN

5. TIPOVI KABELA

5. CABLE TYPES

5.1. XHP 48, XHP 48-A


Energetski kabel za nazivni napon
U0/U=6/10 kV
5.2. XHP 84, XHP 84-A
Energetski kabel, armiran, za nazivni napon
U0/U=6/10 kV
5.3. XHP 49, XHE 49-A
Energetski kabel za nazivne napone
U0/U=12/20kV,18/30 kV i 20,8/36 kV
5.4. XHP 48/0-A
Energetski samonosivi kabelski snop za
nazivne napone
U0/U=6/10 kV, 12/20 kV i 20,8/36 kV
5.5. XLPE-Ay Tip 23, XLPE-Ay Tip 27
Izolirani nadzemni vod za nazivni napon
U0/U=12/20 kV
5.6. XHEh 91, XHEh 91-A
Energetski kabel s dodatnom elektri~nom
za{titom za nazivne napone
U0/U=6/10 kV, 12/20 kV i 20,8/36 kV
5.7. XHE 46/29
Energetski podmorski kabel, jedno`ilni, za
nazivne napone
U0/U=6/10kV, 12/20kV i 20,8/36 kV
5.8. XHE 49/24
Energetski podmorski kabel, tro`ilni, za
nazivne napone
U0/U=6/10kV, 12/20 kV i 20,8/36 kV

11

13

15

17

18

18

5.1. XHP 48, XHP 48-A


Power cable for nominal voltage
U0/U=6/10 kV
5.2. XHP 84, XHP 84-A
Power cable, armoured, for nominal voltage
U0/U=6/10 kV
5.3. XHE 49, XHE 49-A
Power cable for nominal voltages
U0/U=12/20 kV, 18/30 kV and 20,8/36 kV
5.4. XHP 48/0-A
Self-supporting cable bundle for
nominal voltages
U0/U=6/10 kV, 12/20 kV and 20,8/36 kV
5.5. XLPE-Ay Type 23, XLPE-Ay Type 27
Insulated overhead insulated conductor for
nominal voltage U0/U=12/20 kV
5.6. XHEh 91, XHEh 91-A
Power cable with additional electric protection
for nominal voltages
U0/U=6/10 kV, 12/20 kV and 20,8/36 kV
5.7. XHE 46/29
Submarine power cable, single-core,
for nominal voltages
U0/U=6/10 kV, 12/20 kV and 20,8/36 kV
5.8. XHE 49/24
Submarine power cable, three-core,
for nominal voltages
U0/U=6/10 kV, 12/20 kV and 20,8/36 kV

11

13

15

17

18

18

6. STRUJNA OPTERE]ENJA

19

6. CURRENT RATINGS

19

7. ELEKTRI^NI PODACI

25

7. ELECTRICAL DATA

25

8. ISPITIVANJE

27

8. TESTS

27

9. PAKIRANJE

28

9. PACKING

28

10. POLAGANJE I SPAJANJE KABELA

30

10. LAYING AND ASSEMBLY

39

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

1. UVOD

1. INTRODUCTION

ELKA je osnovana 1927. godine i danas je u Republici


Hrvatskoj jedini proizvo|a~ energetskih distribucijskih kabela
napona 1 kV do 36 kV. Elka je i proizvo|a~ XLPE i
elastomernih izolacijskih smjesa za izolacije niskonaponskih i
srednjenaponskih energetskih kabela s vi{e od 20 godina
iskustva na razli~itim proizvodima i komercijalnom plasmanu.
Srednjenaponski kabeli s XLPE izolacijom proizvode se
najsuvremenijom tehnologijom izoliranja u trostrukom
brizganju istovremenim nano{enjem poluvodljivih slojeva na
izolaciju (triplex extrusion).
Umre`enje izolacije je suhim postupkom (dry cured
vulcanisation) u neutralnom plinu du{iku. Ovim postupcima
dobiva se kvalitetan i ~vrst spoj izme|u izolacije i vodljivih
slojeva bez mogu}nosti odvajanja pri ciklusima grijanja i
hla|enja kabela u radu. Umre`enjem u du{iku pove}ana je
otpornost izolacije na nastajanje i {irenje "treeinga" a time i
pojava parcijalnog izbijanja, {to zna~ajno podi`e stupanj
dielektri~ke ~vrsto}e izolacije i produ`ava `ivotni vijek kabela.
Elka posjeduje vlastiti razvojni centar i ispitne laboratorije za
materijale i kabele sa suvremenom opremom i visoko stru~nim
osobljem {to garantira visoku kvalitetu finalnih proizvoda,
materijala i kabela.
Sustav osiguranja kvalitete (Quality Management System)
potvr|en je Certifikatom ISO 9001 izdanim 1997. godine, a
Sustav upravljanja okoliem certifikatom ISO 14001 izdanim
2002. godine od tvrtke SGS International Certification Services
AG, [vicarska.

ELKA was founded in 1927 and is currently the only producer


of distribution power cables of 1 kV to 36 kV voltage in the
Republic of Croatia. ELKA produces also XLPE and elastomere insulation compounds for insulation of low voltage and
medium voltage power cables, with more than 20 years of
experience in proper products and commercial sale.
Medium voltage cables with XLPE insulation are manufactured with most recent technology of insulation in triple extrusion under simultaneous application of semi-conductive layers
over insulation (triplex extrusion).
Cross-linking of insulation is done by dry cured vulcanisation
procedure in a neutral nitrogen gas. By those procedures we
obtain a high quality and tight connection between insulation
and conductive layers without the possibility of their separation
during the heating and cooling cycles of cables in operation.
Cross-linking in nitrogen increases the resistance of insulation
towards appearance and spreading of "treeing" and thereby
also of partial discharge, increasing thus considerably the grade
of dielectric strength of insulation and prolonging the life-time
of cables.
ELKA has got a proper development centre and test laboratories for materials and cables with up to date equipment and
high qualified staff, what guarantees a high quality of final
products, materials and cables.
The Quality Management (Insurance) System is confirmed by
ISO 9001 Certificate, issued in 1997, and Environmental
Management by ISO 14001 Certificate, issued in 2002 by the
firm SGS International Certification Services AG, Switzerland.

1
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

2. PRIMJENJENI STANDARDI

2. APPLIED STANDARDS

Svi materijali, konstrukcije kabela i ispitivanja na energetskim


distributivnim srednjenaponskim kabelima proizvodnje ELKA
u skladu su sa slijede}im me|unarodnim i nacionalnim
standardima:

All materials, cable construction and tests on distribution


medium voltage power cables of ELKA's production, comply
with the following international and national standards:

HRN HD 620 S1/2001: Distribucijski kabeli s brizganom izolacijom za nazivne napone od 3,6/6 kV do 20,8/36 kV

HRN HD 620 S1/2001: Distribution cables with spouted insulation for nominal voltages from 3,6/6 kV up to
20,8/36 kV
IEC 60 502-2/97: Power cables with extruded insulation and
their accessories for rated voltages from 1 kV (Um =
1,2 kV) up to 30 kV (Um = 36 kV)
Part 2: Cables for rated voltages from 6 kV up to
30 kV
IEC 60 287/82: Calculation of the continuous current rating
of cables (100 % load factor)
IEC 60 332-1/93: Tests on electric cables under fire conditions
Part 1: Test on a single vertical insulated wire or
cable
IEC 60 332-3/93: Tests on electric cables under fire conditions
Part 3: Test on bunched wires or cables
IEC 60 754-2/91: Determination of degree of acidity of gases
evolved during the combustion of materials taken
from electric cables by measuring pH and conductivity
SFS 5791/94: 12/20 kV overhead lines. XLPE-covered overhead conductors PAS
ELKA ISE-A-003/97: Power cables for nominal voltages from
1 kV up to 35 kV
ELKA ISE-A-004/99: Insulated overhead conductor for nominal voltage U0/U = 12/20 kV
HEP: Bilten number 100 : 2002
HRN N.CO.006/83: Designation of insulated conductors and
cables

IEC 60 502-2/97: Power cables with extruded insulation and


their accessories for rated voltages from 1 kV
(Um=1,2 kV up to 30 kV (Um=36 kV)
Part 2: Cables for rated voltages from 6 kV up to 30 kV
IEC 60 287/82: Calculation of the continuos current rating of
cables (100% load factor)
IEC 60 332-1/93: Tests on electric cables under fire conditions
Part 1: Test on a single vertical insulated wire or cable

IEC 60 332-3/92: Tests on electric cables under fire conditions


Part 3: Test on bunched wires or cables
IEC 60 754-2/91: Determination of degree of acidity of gases
evolved during the combustion of materials taken
from electric cables by measuring pH and conductivity.
SFS 5791/94: 12/20 kV overhead lines. XLPE-covered overhead conductors PAS
ELKA ISE-A-003/97: Energetski kabeli za nazivne napone od
1 kV do 35 kV
ELKA ISE-A-004/99: Izolirani nadzemni vod za nazivni napon U0/U=12/20 kV
HEP: Bilten broj 100 :2002
HRN N.CO.006/83: Ozna~ivanje izoliranih vodova i kabela

2
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

3. OZNA^IVANJE KABELA

3. CABLE DESIGNATION

U tehni~koj dokumentaciji i narud`bama kabeli su ozna~eni


prema oznakama iz Poglavlja 4 ovog kataloga u skladu s HRN
N.CO.006/1983 i ni`e danim zna~enjima:

In technical documentation and orders, cables are marked acc.


to designations of Chapter 4 of the present catalogue, pursuant
to HRN N.CO.006/1983 and below stated meanings:

3.1. Vrste materijala

3.1. Types of material

A - aluminij
Ay - aldrey (legura AlMgSi)
X - umre`eni polietilen
P - polivinilklorid-PVC
E - polietilen
O - poliolefin
H - poluvodljivi slojevi oko izolacije
h - poluvodljivi pla{t

A
Ay
X
P
E
O
H
h

3.2. Design features significant for application

3.2. Svojstva konstrukcije zna~ajne za primjenu


V
/O
HF
TG
U0/U/Um

-aluminium
-aldrey (AlMgSi alloy)
-cross-linked polyethylene
-polyvinyl chloride - PVC
-polyethylene
-polyolefine
-semi-conductive layers around insulation
-semi-conductive sheath

V
/O
HF
TG
U0/U/Um

- uzdu`na vodonepropusnost
- samonosiv
- bez halogenih materijala
- otporni na {irenje plamena
- oznaka naponskog nivoa kabela

-longitudinal water-impermeability
-self-supporting
-halogen free
-resistant to fire propagation
-designation of cable voltage level

3.3. Design features significant for elaboration

3.3. Svojstva konstrukcije zna~ajna za izvedbu

24 -armour of round galvanised steel wires with external


sheath made of thermoplastic high-density polyethylene
(PE-HD)
29 -armour of round nonmagnetic wires with external protective sheath made of thermoplastic high-density polyethylene (PE-HD)
36 -armour of special aluminium round wires
46 -electrical protection laid around each cable core in the
shape of wrappings of copper wires or copper strips,
wrappings of water-swelling strips for longitudinal waterimpermeability and longitudinally laid aluminium strip
coated with a layer of copolymer ethylene for transversal
water-impermeability.
48 -electric protection/screen around each separate core
49 -electric protection/screen around each separate core and
longitudinal water-tightness of cable
84 -electric protection around each separate core, armour of
steel galvanised round wires and coil of galvanised steel
tape
91 -additional electrical protection made of tinned copper
wires over the external protective sheath
94 -waterproof electric protection around each separate core,
armour of steel galvanised round wires and coil of
galvanised steel tape.

24 - armatura od pocin~anih okruglih ~eli~nih `ica s vanjskim


pla{tom od termoplasti~nog polietilena visoke gusto}e
(PE-HD)
29 - armatura od okruglih nemagnetskih `ica s vanjskim za{titnim pla{tom od termoplasti~nog polietilena visoke gusto}e (PE-HD)
36 - armatura od specijalnih aluminijskih okruglih `ica
46 - elektri~na za{tita postavljena oko svake `ile kabela u obliku omota bakrenih `ica ili bakrenih traka, omota od vodobubrivih traka za uzdu`nu vodonepropusnost i uzdu`no
postavljene aluminijske trake presvu~ene slojem kopolimer etilena za popre~nu vodonepropusnost
48 - elektri~na za{tita/ekran oko svake `ile pojedina~no
49 - elektri~na za{tita/ekran oko svake `ile pojedina~no i uzdu`na vodonepropusnost kabela
84 - elektri~na za{tita oko svake `ile pojedina~no, armatura
od pocin~anih ~eli~nih okruglih `ila i zavojnica od pocin~ane ~eli~ne trake
91 - dodatna elektri~na za{tita od bakrenih pokositrenih `ica
iznad vanjskog za{titnog pla{ta
94 - vodonepropusna elektri~na za{tita oko svake `ile pojedina~no, armatura od ~eli~nih pocin~anih okruglih `ica i zavojnica od pocin~ane ~eli~ne trake.

3
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

3.4. Primjeri ozna~ivanja

3.4. Examples of designation

a) XHP 48 3x95/16 mm2 6/10/12 kV


Kabel s izolacijom od umre`enog polietilena s poluvodljivim
slojem ispod i iznad izolacije, tro`ilni, s faznim vodi~ima od
bakra presjeka 95mm2, s elektri~nom za{titom od bakra
presjeka 16mm2 raspodjeljene oko svake `ile posebno, s PVC
pla{tom, za nazivni napon U0/U=6/10 kV i najvi{i napon mre`e
Um=12kV.

a) XHP 48 3 x 95/16 mm26/10/12 kV


Cable with insulation of cross-linked polyethylene, with semiconductive layer beneath and over insulation, three-core, with
copper phase conductors of 95 mm2 cross-section, copper
electric protection of 16 mm2 cross-section distributed around
each separate core, with PVC sheath, for nominal voltage U0/U
= 6/10 kV and highest network voltage Um = 12 kV.

b) XHE 49-A 1x185/25 mm2 12/20/24 kV


Kabel s izolacijom od umre`enog polietilena, s poluvodljivim
slojem ispod i iznad izolacije, jedno`ilni, s faznim vodi~em od
aluminija presjeka 185 mm2, s elektri~nom za{titom od bakra
presjeka 25 mm2, vodonepropusnom izvedbom eletri~ne za{tite, s PE pla{tom, za nazivni napon U0/U=12/20 kV i najvi{i
napon mre`e Um=24kV.

b) XHE 49-A 1x185/25 mm2 12/20/24 kV


Cable with insulation of cross-linked polyethylene, with semiconductive layer beneath and over insulation, single-core, with
aluminium phase conductor of 185 mm2 cross-section, copper
electric protection of 25 mm2 cross-section, longitudinally
executed watertight electric protection, PE sheath, for nominal
voltage U0/U=12/20 kV and highest network voltage Um=24
kV.

c) XHO 49-HFTG 1x150/25 mm2 20,8/36/42 kV


Kabel s izolacijom od umre`enog polietilena, s poluvodljivim
slojem ispod i iznad izolacije, jedno`ilni, s faznim vodi~em od
bakra presjeka 150 mm2, s elektri~nom za{titom od bakra
presjeka 25 mm2, s vodonepropusnom izvedbom elektri~ne
za{tite, s poliolefinskim pla{tom, za nazivni napon mre`e
U0/U=20,8/36 kV i najvi{i napon mre`e Um=42kV, bez halogenih materijala, te{ko goriv.

c) XHO 49-HFTG 1x150/25 mm2 20,8/36/42 kV


Cable with insulation of cross-linked polyethylene, with semiconductive layer beneath and over insulation, single-core, with
copper phase conductor of 150 mm2 cross-section, copper
electric protection of 25 mm2 cross-section, longitudinally
executed watertight electric protection, polyolefine sheath, for
nominal network voltage U0/U=20,8/36 kV and highest network voltage Um=42 kV, halogen free, flame-retardant.

d) XHP 48/36-A 1x400/35 mm2 20,8/36/42 kV


Kabel s izolacijom od umre`enog polietilena, s poluvodljivim
slojem ispod i iznad izolacije tro`ilni, s faznim vodi~ima od
aluminija presjeka 400 mm2, s elektri~nom za{titom od bakra
presjeka 35 mm2, s unutarnjim pla{tom od PVC, s armaturom od
aluminijske legure, s PVC pla{tom, za nazivni napon
U0/U=20,8/36 kV i najvi{i napon mre`e Um=42kV.

d) XHP 48/36-A 1x400/35 mm2 20,8/36/42 kV


Cable with insulation of cross-linked polyethylene, with semiconductive layer beneath and over insulation, single-core, with
aluminium phase conductor of 400 mm2 cross-section, copper
electric protection of 35 mm2 cross-section, inner PVC sheath,
armour of aluminium alloy, PVC sheath, for nominal voltage
U0/U=20,8/36 kV and highest network voltage Um=42 kV.

e) XHE 49/24 3x120/16 mm2 6/10/12 kV


Kabel s izolacijom od umre`enog polietilena, s poluvodljivim
slojem ispod i iznad izolacije, tro`ilni, s faznim vodi~ima
od bakra presjeka 120 mm2, s elektri~nom za{titom od bakra
presjeka 16 mm2 raspodjeljene oko svake `ile posebno s
vodonepropusnom izvedbom elektri~ne za{tite, s unutarnjim
pla{tom od PE, armaturom od pocin~anih ~eli~nih okruglih `ica
i vanjskim PE pla{tom, za nazivni napon U0/U=6/10kV i najvi{i
napon mre`e Um=12 kV.

e) XHE 49/24 3x120/16 mm2 6/10/12 kV


Cable with insulation of cross-linked polyethylene, with semiconductive layer beneath and over insulation, three-core, with
copper phase conductors of 120 mm2 cross-section, copper
electric protection of 16 mm2 cross-section, distributed around
each separate core, longitudinally executed watertight electric
protection, inner PE sheath, armour of galvanised steel round
wires, external PE sheath, for nominal voltage U0/U=6/10 kV
and highest network voltage Um=12 kV.

f) XHP 84-A 3x185/25 mm2 12/20/24 kV


Kabel s izolacijom od umre`enog polietilena, s poluvodljivim
slojem ispod i iznad izolacije, tro`ilni, s 3 fazna aluminijska
vodi~a presjeka 185 mm2, s elektri~nom za{titom od bakra
presjeka 25 mm2 raspodjeljene oko svake `ile posebno, s
unutarnjim omota~em od brizganog PVC, s armaturom od
pocin~anih ~eli~nih okruglih `ica i zavojnicom od pocin~ane

f) XHP 84-A 3x185/25 mm2 12/20/24 kV


Cable with insulation of cross-linked polyethylene, with semiconductive layer beneath and over insulation, three-core, with
three aluminium phase conductors of 185 mm2 cross-section,
copper electric protection of 25 mm2 cross-section, distributed
around each separate core, inner jacket of extruded PVC,
armour of galvanised steel round wires, coil of galvanised steel

4
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

~eli~ne vrpce, s PVC pla{tom, za nazivni napon U0/U=12/20 kV


i najvi{i napon mre`e Um=24kV.

tape, PVC sheath, for nominal voltage U0/U=12/20 kV and


highest network voltage Um=24 kV.

g) XHE 46/29 V 1x120/16 mm2 12/20/24 kV


Kabel s izolacijom od umre`enog polietilena, s poluvodljivim
slojem ispod i iznad izolacije, jedno`ilni s faznim uzdu`no
nepropusnim vodi~em od bakra presjeka 120 mm2, s uzdu`no i
popre~no vodonepropusnom elektri~nom za{titom presjeka 16
mm2, s unutarnjim pla{tom od PE-HD, armaturom od okruglih
aluminijskih (ili drugog nemagnetnog materijala) `ica i
vanjskim za{titnim pla{tom od PE-HD, za nazivni napon
U0/U=12/20 kV i najvi{i napon mre`e Um=24 kV.

2
g) XHE 46/29 V 1x120/16 mm 12/20/24 kV
Cable with cross-linked polyethylene insulation, with semi-conductive layer beneath and over the insulation, single-core with
longitudinally impenetrable copper phase conductor of crosssection 120 mm2, with longitudinally and transversally watertight electrical protection of cross-section 16 mm2, with inner
sheath of PE-HD, armour made of round aluminium (or of
another nonmagnetic material) wires, and the external protective sheath of PE-HD, for nominal voltage U0/U=12/20 kV and
the highest network voltage Um=24 kV.

h) XHEh 91 1x150/25/60 mm2 20,8/36/42 kV


Kabel s izolacijom od umre`enog polietilena, s poluvodljivim
slojem ispod i iznad izolacije, jedno`ilni, s faznim vodi~em od
bakra presjeka 150 mm2, s elektri~nom za{titom od bakra
presjeka 25 mm2, s vanjskim pla{tom od poluvodljivog PE i
dodatnom elektri~nom za{titom nazivnog presjeka 60 mm2
postavljenom koncentri~no preko vanjskog pla{ta, za nazivni
napon U0/U=20,8/36 kV i najvi{i napon mre`e Um=42 kV.

h) XHEh 91 1x150/25/60 mm2 20,8/36/42 kV


Cable with insulation of cross-linked polyethylene, with semiconductive layer beneath and over insulation, single-core, with
copper phase conductor of 150 mm2 cross-section, copper
electric protection of 25 mm2 cross-section, external sheath of
semi-conductive PE, additional electric protection of nominal
cross-section 60 mm2 deposited concentrically over external
sheath, for nominal voltage U0/U=20,8/36 kV and highest network voltage Um=42 kV.

i) XHP 48/O-A 3x1x95/16 mm2 6/10/12 kV


Kabelski snop koji se sastoji od tri jedno`ilna kabela tipa XHP
48-A s aluminijskim faznim vodi~em presjeka 95 mm2 i opisa
konstrukcije kao pod a), zajedno pou`ena oko nosivog PE
presvu~enog ~eli~nog u`eta, za nazivni napon U0/U=6/10 kV i
najvi{i napon mre`e Um=12 kV.

i) XHP 48/O-A 3x1x95/16 mm2 6/10/12 kV


Cable bundle consisting of three single-core cables of XHP 48A type, with aluminium phase conductor of 95 mm2 crosssection, and construction description as under a), stranded
together around supporting conductor of PE coated steel rope,
for nominal voltage U0/U=6/10 kV and highest network
voltage Um=12 kV.

j) XLPE-Ay TIP 27 95 mm2 12/20/24 kV


Izolirani vodi~ s XLPE izolacijom debljine 2,7 mm, s faznim
vodi~em od AlMgSi, za nazivni napon U0/U=12/20 kV i najvi{i
napon mre`e Um=24 kV.

j) XLPE-Ay Type 27 95 mm2 12/20/24 kV


Insulated conductor with XLPE insulation of 2,7 mm thickness, with phase conductor of AlMgSi, for nominal voltage
U0/U=12/20 kV and highest network voltage Um=24 kV.

3.5. Ozna~ivanje na pla{tu kabela

3.5. Cable sheath marking

Na svakoj proizvedenoj duljini kabela oznaka kabela prema 3.4.


dopunjava se sa:
1. ELKA ZAGREB
2. godina proizvodnje
3. IEC standardi
IEC 332-3, za te{kogorivi tip kabela
IEC 332-3 IEC 754, za te{kogorivi i bezhalogeni tip
kabela
4. metri~kom oznakom duljine

Each produced cable length designation acc. to 3.4 is supplemented by:


1. ELKA ZAGREB
2. Year of production
3. IEC standards:
IEC 332-3, for flame-retardant cable type
IEC 332-3, IEC 754, for flame-retardant and halogen
free cable type
4. Metrical length mark

5
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

4. KONSTRUKCIJA KABELA

4. CABLE DESIGN

4.1. Konstrukcije i tipovi jedno`ilnih kabela

4.1. Designs and types of single-core cables

XHP 48, XHP 48-A; XHE 49, XHE 49-A; XHO 49, XHO 49-A

XHP 48/36, XHP 48/36-A; XHE 49/29, XHE 49/29-A; XHO 49/36, XHO 49/36-A, XHE 46/29, XHE 46/29-A

1 - Vodi~, bakar ili aluminij, IEC 228 kl.2


2 - Ekran vodi~a, brizgana umre`ena poluvodljiva smjesa
3 - Izolacija, brizgani umre`eni polietilen - XLPE
4 - Ekran izolacije, brizgana umre`ena poluvodljiva smjesa
5 - Elektri~na za{tita/ekran, bakrene `ice + bakrena traka
Izvedba 48: poluvodljiva vrpca ispod, a izolacijska vrpca
iznad `ica
Izvedba 49: poluvodljiva bubriva vrpca ispod, a izolacijska
bubriva vrpca iznad `ica
6 - unutarnji pla{t: brizgani PVC ili PE
7 - Armatura: Specijalne aluminijske `ice (48/36 ili 46/29)
8 - Vanjski pla{t: brizgani PVC (XHP) ili PE (XHE) i PO (XHO)

1 - Conductor, copper or aluminium, class 2, IEC 228


2 - Conductor screen, extruded cross-linked semi-conductive
compound
3 - Insulation, extruded cross-linked polyethylene - XLPE
4 - Insulation screen, extruded cross-linked semi-conductive
compound
5 - Electric protection/screen, copper wires + copper tape
Construction 48: semi-conductive tape beneath and insulation one over the wires
Construction 49: semi-conductive swelling tape beneath
and insulation swelling tape over the wires
6 - Inner sheath, extruded PVC or PE
7 - Armour, special aluminium wires (48/36 or 46/29)
8 - External sheath, extruded PVC (XHP) or PE (XHE) and
PO (HXO)

6
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

4.2. Designs and types of three-core cables

4.2. Konstrukcija i tipovi tro`ilnog kabela

XHP 48, XHP 48-A; XHE 49, XHE 49-A; XHO 49, XHO 49-A

XHP 84, XHP 84-A; XHE 94, XHE 94-A; XHO 94, XHO 94-A, XHE 49/24

- Vodi~, bakar ili aluminij, zbijeno u`e kl. 2 IEC 228


- Ekran vodi~a, brizgana umre`ena poluvodljiva smjesa
- Izolacija, brizgani umre`eni polietilen - XLPE
- Ekran izolacije, brizgana umre`ena poluvodljiva smjesa
- Elektri~na za{tita/ekran: bakrene trake
Izvedba 48: poluvodljiva vrpca ispod bakrene trake, a specijalna ispuna oko pou`enih `ila
Izvedba 49: poluvodljiva bubriva vrpca ispod bakrene trake, a specijalna ispuna oko pou`enih `ila
6 - Unutarnji pla{t: brizgani PVC, PE ili PO
7 - Armatura: ~eli~ne pocin~ane okrugle `ice, sa ili bez ~eli~ne
pocin~ane trake kao protuzavojnice
8 - Vanjski pla{t: brizgani PVC (XHP), PE (XHE) ili PO (XHO)

1 - Conductor, copper or aluminium, compacted rope, class 2,


IEC 228
2 - Conductor screen, extruded cross-linked semi-conductive
compound
3 - Insulation, extruded cross-linked polyethylene - XLPE
4 - Insulation screen, extruded cross-linked semi-conductive
compound
5 - Electric protection/screen, copper tapes
Construction 48: semi-conductive tape beneath copper
tape and special filler around stranded cores
Construction 49: semi-conductive swelling tape beneath
copper tape and special filler around stranded cores
6 - Inner sheath, extruded PVC, PE or PO
7 - Armour, galvanised steel round wires with or without steel
galvanised tape acting as counter-coil
8 - External sheath, extruded PVC (XHP), PE (XHE) or PO
(HXO)

1
2
3
4
5

7
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

5. TIPOVI KABELA

5. CABLE TYPES

5.1. XHP 48, XHP 48-A


Energetski kabel za nazivni napon U0/U=6/10 kV
5.2. XHP 84, XHP 84-A
Energetski kabel, armiran, za nazivni napon U0/U=6/10 kV
5.3. XHP 49, XHE 49-A
Energetski kabel za nazivne napone
U0/U=12/20kV, 18/30 kV i 20,8/36 kV
5.4. XHP 48/0-A
Energetski samonosivi kabelski snop za nazivne napone
U0/U=6/10 kV, 12/20 kV i 20,8/36 kV
5.5. XLPE-Ay Tip 23, XLPE-Ay Tip 27
Izolirani nadzemni vod za nazivni napon U0/U=12/20 kV

5.1. XHP 48, XHP 48-A


Power cable for nominal voltage U0/U=6/10 kV
5.2. XHP 84, XHP 84-A
Power cable, armoured, for nominal voltage U0/U=6/10 kV
5.3. XHE 49, XHE 49-A
Power cable for nominal voltages
U0/U=12/20 kV, 18/30 kV and 20,8/36 kV
5.4. XHP 48/0-A
Self-supporting cable bundle for nominal voltages
U0/U=6/10 kV, 12/20 kV and 20,8/36 kV
5.5. XLPE-Ay Type 23, XLPE-Ay Type 27
Insulated overhead insulated conductor for nominal voltage U0/U=12/20 kV
5.6. XHEh 91, XHEh 91-A
Power cable with additional electric protection for nominal
voltages U0/U=6/10 kV, 12/20 kV and 20,8/36 kV
5.7. XHE 49/24
Submarine power cable, single-core, for nominal voltages
U0/U=6/10 kV, 12/20 kV and 20,8/36 kV

5.6. XHEh 91, XHEh 91-A


Energetski kabel s dodatnom elektri~nom za{titom za nazivne napone U0/U=6/10 kV, 12/20 kV i 20,8/36 kV
5.7. XHE 49/24
Energetski podmorski kabel, jedno`ilni, za nazivne napone
U0/U=6/10kV, 12/20kV i 20,8/36 kV
5.8. XHE 46/29
Energetski podmorski kabel, jedno`ilni, za nazivne napone
U0/U=6/10kV, 12/20 kV i 20,8/36 kV

5.8. XHE 46/29


Submarine power cable, single-core, for nominal voltages
U0/U=6/10 kV, 12/20 kV and 20,8/36 kV

8
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

XHP 48, XHP 48-A

5.1. ENERGETSKI KABEL S XLPE IZOLACIJOM I PVC


PLA[TOM

5.1. POWER CABLE WITH XLPE INSULATION AND PVC


SHEATH

Tipska oznaka po HRN HD: N2XSY, NA2XSY


Tipska oznaka po DIN VDE: N2XSY, NA2XSY

Type coded acc. to HRN HD: N2XSY, NA2XSY


Type coded acc. to DIN VDE: N2XSY, NA2XSY

Standardi i norme: HRN HD 620 S1 Part 5 C-2


IEC 60 502-2
DIN VDE 0276T 620

Standards and norms: HRN HD 620 S1 Part 5 C-2


IEC 60502-2
DIN VDE 0276T 620

Nazivni napon: U0/U=6/10 kV


Najvi{i napon mre`e: Um=12 kV
Ispitni napon: Ui=15 kV

Nominal voltage: U0/U=6/10 kV


Max.network voltage: Um=12 kV
Test voltage: Ui=15 kV

OPIS KONSTRUKCIJE

CONSTRUCTION DESCRIPTION

Vodi~: bakreno ili aluminijsko u`e, zbijeno


Ekran vodi~a: Poluvodljivi sloj na vodi~u
Izolacija: XLPE
Ekran izolacije: Poluvodljivi sloj na izolaciji
Elektri~na za{tita/ekran: od bakrene `ice (jedno`ilni) ili
bakrene trake (tro`ilni)
6. Separator: poliesterska vrpca
7. Ispuna: PVC
8. Vanjski pla{t: PVC

1.
2.
3.
4.
5.

Conductor: copper or aluminium rope, compacted


Conductor screen: semi-conductive layer over conductor
Insulation: XLPE
Insulation screen: semi-conductive layer over insulation
Electric protection/screen: of copper wire (single-core) or
copper tape (three-core)
6. Separator: polyester tape
7. Filler: PVC
8. External sheath: PVC

1.
2.
3.
4.
5.

MJESTO I PODRU^JE UPORABE

PLACE AND FIELD OF APPLICATION

U zemlju, kanale, na konzole, gdje se ne o~ekuju mehani~ka


o{te}enja ni mehani~ka vla~na naprezanja.
Kao distributivni kabel u gradskim i ruralnim mre`ama. Kao
spojni kabel za industrijske pogone.

In earth, ducts, on cable trays, where no mechanical damages


nor mechanical tensile strains are expected.
As distributive cable in urbane and rural networks. As
connecting cable for industrial plants.

9
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

5.1.1. Izmjere i te`ine XHP 48, XHP 48-A

ELECTRIC

CABLE

WORKS

5.1.1. Sizes and weights XHP 48, XHP 48-A

6/10/12 kV

Presjek vodi~a i el.


za{tite / Cross-section
of Conductor and
Electric Protection

Promjer
vodi~a /
Conductor
Cross-section

Debljina
izolacije /
Insulation
Thickness

Promjer preko
izolacije /
Diameter over
Insulation

Promjer
kabela cca /
Cable Diameter
approx.

nxmm2/mm2

mm

mm

mm

mm

kg/km

kg/km

mm

1x25/16
1x35/16
1x50/16
1x70/16
1x95/16
1x120/16
1x150/25
1x185/25
1x240/25
1x300/25
1x400/35
1x500/35

6,1
7,2
8,3
10,3
11,3
12,7
14,1
15,7
18,0
20,0
23,8
26,7

3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4

15,1
16,2
17,3
19,3
20,3
21,7
23,1
24,7
27,2
29,2
33,2
36,1

22
23
25
27
28
30
32
35
37
39
41
44

750
890
1020
1210
1520
1770
2150
2570
3100
3750
4750
5880

610
660
750
850
950
1060
1250
1430
1600
1850
2300
2550

330
340
370
400
420
450
480
520
550
580
610
660

5.1.2. Izmjere i te`ine XHP 48, XHP 48-A

Te`ina kabela cca /


Cable Weight approx.
bakar /
aluminij /
copper
aluminium

6/10/12 kV

Najmanji polumjer
savijanja /
Minimal Bending
Radius

5.1.2. Sizes and weights XHP 48, XHP 48-A

6/10/12 kV

Te`ina kabela cca /


Cable Weight approx.
bakar /
aluminij /
copper
aluminium

6/10/12 kV

Presjek vodi~a i el.


za{tite / Cross-section
of Conductor and
Electric Protection

Promjer
vodi~a /
Conductor
Cross-section

Debljina
izolacije /
Insulation
Thickness

Promjer preko
izolacije /
Diameter over
Insulation

Promjer
kabela cca /
Cable Diameter
approx.

Najmanji polumjer
savijanja /
Minimal Bending
Radius

nxmm2/mm2

mm

mm

mm

mm

kg/km

kg/km

mm

3x25/16
3x35/16
3x50/16
3x70/16
3x95/16
3x120/16
3x150/25
3x185/25
3x240/25
3x300/25

6,1
7,2
8,3
10,3
11,3
12,7
14,1
15,7
18,0
20,0

3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4

15,1
16,2
17,3
19,3
20,3
21,7
23,1
24,7
27,2
29,2

44
46
48
51
55
60
64
66
71
76

2850
3200
3750
4500
5500
6800
8000
9200
10700
13100

2350
2550
2800
3200
3750
4600
5200
5750
6200
7500

520
550
570
610
660
720
760
790
850
910

10
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

XHP 84, XHP 84-A

5.2. ENERGETSKI KABELI S XLPE IZOLACIJOM I PVC


PLA[TOM ARMIRANI S OKRUGLIM ^ELI^NIM
@ICAMA

5.2. POWER CABLES WITH XLPE INSULATION AND PVC


SHEATH ARMOURED WITH ROUND STEEL WIRES

Tipska oznaka po HRN HD: E-2XHCEYRY,


E-A2XHCEYRY
Tipska oznaka po DIN VDE: N2XSEYRY,
NA2XSEYRY

Type coded acc. to HRN HD: E-2XHCEYRY,


E-2AXHCEYRY
Type coded acc. to DIN VDE: N2XSEYRY,
NA2XSEYRY

Standardi i norme: HD 620 S1 Part 6 A-2


IEC 60 502-2

Standards and norms: HD 620 S1 Part 6 A-2


IEC 60502-2

Nazivni napon: U0/U=6/10 kV


Najvi{i napon mre`e: Um=12 kV
Ispitni napon: Ui=15 kV

Nominal voltage: U0/U=6/10 kV


Max.network voltage: Um=12 kV
Test voltage: Ui=15 kV

OPIS KONSTRUKCIJE

CONSTRUCTION DESCRIPTION

Vodi~: bakreno ili aluminijsko u`e, zbijeno


Ekran vodi~a: Poluvodljivi sloj na vodi~u
Izolacija: XLPE
Ekran izolacije: Poluvodljivi sloj na izolaciji
Elektri~na za{tita/ekran: od bakrene trake
Unutarnji pla{t: PVC
Armatura: ~eli~ne pocin~ane okrugle `ice i zavojnica od
pocin~ane ~eli~ne trake
8. Vanjski pla{t: PVC

1. Conductor: copper or aluminium rope, compacted


2. Conductor screen: semi-conductive layer over conductor
3. Insulation: XLPE
4. Insulation screen: semi-conductive layer over insulation
5. Electric protection/screen: of copper tape
6. Inner sheath: PVC
7. Armour: galvanised steel round wires and coils of galvanised
steel tape
8. External sheath: PVC

1.
2.
3.
4.
5.
6.
7.

MJESTO I PODRU^JE UPORABE

PLACE AND FIELD OF APPLICATION

U zemlju, kanale, na konzole, gdje se o~ekuju mehani~ka


o{te}enja i velika mehani~ka vla~na naprezanja, za polaganje na
kosim terenima. Kao distributivni kabel u gradskim i ruralnim
mre`ama. Kao spojni kabel za industrijske pogone.

In earth, ducts, on cable trays, where mechanical damages and


severe mechanical tensile strains are expected, for laying on
sloping grounds.
As distributive cable in urbane and rural networks. As connecting cable for industrial plants.

11
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

5.2.1. Sizes and weights XHP 84, XHP 84-A

5.2.1. Izmjere i te`ine XHP 84, XHP 84-A 6/10/12 kV

Te`ina kabela cca /


Cable Weight approx.
bakar /
aluminij /
copper
aluminium

6/10/12 kV

Presjek vodi~a i el.


za{tite / Cross-section
of Conductor and
Electric Protection

Promjer
vodi~a /
Conductor
Cross-section

Debljina
izolacije /
Insulation
Thickness

Promjer preko
izolacije /
Diameter over
Insulation

Promjer
kabela cca /
Cable Diameter
approx.

Najmanji polumjer
savijanja /
Minimal Bending
Radius

nxmm2/mm2

mm

mm

mm

mm

kg/km

kg/km

mm

3x25/16
3x35/16
3x50/16
3x70/16
3x95/16
3x120/16
3x150/25
3x185/25
3x240/25
3x300/25

6,1
7,2
8,3
10,3
11,3
12,7
14,1
15,7
18,0
20,0

3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4
3,4

15,1
16,2
17,3
19,3
20,3
21,7
23,1
24,7
27,2
29,2

50
52
54
57
61
66
71
73
78
83

4900
5400
6000
6900
8100
9700
11600
12900
14700
17400

4400
4750
5050
5600
6400
7500
8800
9500
10200
11800

600
620
650
680
730
790
850
870
930
1000

12
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

XHE 49, XHE 49-A

5.3. ENERGETSKI KABELI S XLPE IZOLACIJOM I PE


PLA[TOM S VODONEPROPUSTNOM IZVEDBOM
ELEKTRI^NE ZA[TITE

5.3. POWER CABLES WITH XLPE INSULATION AND PVC


SHEATH AND WATERTIGHT CONSTRUCTION OF
ELECTRIC PROTECTION

Tipska oznaka po HRN HD: N2XS(F)2Y, NA2XS(F)2Y


Tipska oznaka po DIN VDE: N2XS(F)2Y, NA2XS(F)2Y

Type coded acc. to HRN HD: N2XS(F)2Y, NA2XS(F)2Y


Type coded acc. to DIN VDE: N2XS(F)2Y, NA2XS(F)2Y

Standardi i norme: HRN HD 620 S1 Part 5C-1


IEC 60 502-2
DIN VDE 0276 T 620

Standards and norms: HRN HD 620 S1 Part 5C-1


IEC 60 502-2
DIN VDE 0276 T 620

Nazivni napon: U0/U=12/20 kV, 18/30 kV, 20,8/36 kV


Najvi{i napon mre`e: Um=2 4 kV, 36 kV, 42 kV
Ispitni napon: Ui=30 kV, 45 kV, 52 kV

Nominal voltage: U0/U=12/20 kV, 18/30 kV, 20,8/36 kV


Max.network voltage: Um=24 kV, 36 kV, 42 kV
Test voltage: Ui=30 kV, 45 kV, 52 kV

OPIS KONSTRUKCIJE

CONSTRUCTION DESCRIPTION

1.
2.
3.
4.
5.
6.
7.
8.

Vodi~: bakreno ili aluminijsko u`e, zbijeno


Ekran vodi~a: Poluvodljivi sloj na vodi~u
Izolacija: XLPE
Ekran izolacije: Poluvodljivi sloj na izolaciji
Separator: bubriva vrpca, poluvodljiva
Elektri~na za{tita/ekran: od bakrenih `ica
Separator: bubriva vrpca
Vanjski pla{t: PE-HD

1.
2.
3.
4.
5.
6.
7.
8.

Conductor: copper or aluminium rope, compacted


Conductor screen: semi-conductive layer over conductor
Insulation: XLPE
Insulation screen: semi-conductive layer over insulation
Separator: swelling tape, semi-conductive
Electric protection/screen: of copper wire
Separator: swelling tape
External sheath: PE-HD

MJESTO I PODRU^JE UPORABE

PLACE AND FIELD OF APPLICATION

U zemlju, vla`ne terene, kanale, na konzole, gdje se ne o~ekuju


mehani~ka o{te}enja ni mehani~ka vla~na naprezanja.
Kao distributivni kabel u gradskim i ruralnim mre`ama.

In earth, wet grounds, ducts, on cable trays, where no mechanical damages or mechanical tensile strains are expected.
As distributive cable in urbane and rural networks.

13
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

5.3.1. Sizes and weights XHE 49, XHE 49-A

5.3.1. Izmjere i te`ine XHE 49, XHE 49-A 12/20/24 kV


Promjer
vodi~a /
Conductor
Cross-section

Debljina
izolacije /
Insulation
Thickness

Promjer preko
izolacije /
Diameter over
Insulation

Promjer
kabela cca /
Cable Diameter
approx.

mm2

mm

mm

mm

mm

kg/km

kg/km

mm

1x25/16
1x35/16
1x50/16
1x70/16
1x95/16
1x120/16
1x150/25
1x185/25
1x240/25
1x300/25
1x400/35
1x500/35

6,1
7,2
8,3
10,3
11,3
12,7
14,1
15,7
18,0
20,0
23,8
26,7

5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5
5,5

19,2
20,3
21,4
23,4
24,4
25,8
27,2
28,8
31,1
33,1
36,9
39,8

29
30
31
33
34
36
37
39
42
45
48
50

950
1050
1200
1450
1700
2000
2250
2700
3300
3950
4900
6000

790
840
900
1000
1100
1200
1400
1550
1800
2100
2500
2900

430
450
460
490
500
540
550
580
630
670
720
750

5.3.2. Izmjere i te`ine XHE 49, XHE 49-A 18/30/36 kV

Te`ina kabela cca /


Cable Weight approx.
bakar /
aluminij /
copper
aluminium

12/20/24 kV

Presjek vodi~a i el.


za{tite / Cross-section
of Conductor and
Electric Protection

Najmanji polumjer
savijanja /
Minimal Bending
Radius

5.3.2. Sizes and weights XHE 49, XHE 49-A


Te`ina kabela cca /
Cable Weight approx.
bakar /
aluminij /
copper
aluminium

18/30/36 kV

Presjek vodi~a i el.


za{tite / Cross-section
of Conductor and
Electric Protection

Promjer
vodi~a /
Conductor
Cross-section

Debljina
izolacije /
Insulation
Thickness

Promjer preko
izolacije /
Diameter over
Insulation

Promjer
kabela cca /
Cable Diameter
approx.

Najmanji polumjer
savijanja /
Minimal Bending
Radius

mm2

mm

mm

mm

mm

kg/km

kg/km

mm

1x35/16
1x50/16
1x70/16
1x95/16
1x120/16
1x150/25
1x185/25
1x240/25
1x300/25
1x400/35
1x500/35

7,2
8,3
10,3
11,3
12,7
14,1
15,7
18,0
20,0
23,8
26,7

8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0
8,0

25,8
26,9
28,9
29,9
31,3
32,7
34,3
36,6
38,6
42,4
45,3

34
35
37
39
41
43
45
47
50
54
56

1250
1450
1700
2050
2300
2700
3000
3700
4300
5300
6400

1050
1150
1300
1400
1500
1750
1900
2200
2400
2900
3400

500
520
550
580
610
640
670
700
750
810
840

5.3.3. Izmjere i te`ine XHE 49, XHE 49-A 20,8/36/42 kV

5.3.3. Sizes and weights XHE 49, XHE 49-A 20,8/36/42 kV

Presjek vodi~a i el.


za{tite / Cross-section
of Conductor and
Electric Protection

Promjer
vodi~a /
Conductor
Cross-section

Debljina
izolacije /
Insulation
Thickness

Promjer preko
izolacije /
Diameter over
Insulation

Promjer
kabela cca /
Cable Diameter
approx.

mm2

mm

mm

mm

mm

kg/km

kg/km

mm

1x35/16
1x50/16
1x70/16
1x95/16
1x120/16
1x150/25
1x185/25
1x240/25
1x300/25
1x400/35
1x500/35

7,2
8,3
10,3
11,3
12,7
14,1
15,7
18,0
20,0
23,8
26,7

8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8
8,8

27,8
28,9
30,9
31,9
33,3
34,7
36,3
38,6
40,6
44,4
47,3

36
37
39
41
43
45
47
49
52
56
58

1400
1650
1900
2200
2500
3000
3300
4000
4700
5700
6600

1180
1350
1450
1600
1750
2050
2150
2500
2850
3200
3500

540
550
580
610
640
670
700
730
780
840
870

Te`ina kabela cca /


Cable Weight approx.
bakar /
aluminij /
copper
aluminium

Najmanji polumjer
savijanja /
Minimal Bending
Radius

14
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

XHP 48/0-A

5.4. ENERGETSKI SAMONOSIVI KABELSKI SNOP S


XLPE IZOLACIJOM

5.4. SELF-SUPPORTING POWER CABLE BUNDLE WITH


XLPE INSULATION

Standardi: HRN HD 620 S1 Part 5C-2


IEC 60 502-2

Standards: HRN HD 620 S1 Part 5C-2


IEC 60 502-2

Nazivni napon: U0/U=6/10 kV, 12/20 kV, 20,8/36 kV


Najvi{i napon mre`e: Um=12 kV, 24 kV, 42 kV
Ispitni napon: Ui=15 kV, 30 kV, 52 kV

Nominal voltage: U0/U=6/10 kV, 12/20 kV, 20,8/36 kV


Max.network voltage: Um=12 kV, 24 kV, 42 kV
Test voltage: Ui=15 kV, 30 kV, 52 kV

OPIS KONSTRUKCIJE

CONSTRUCTION DESCRIPTION

1.
2.
3.
4.
5.
6.
7.
8.

Vodi~: aluminijsko u`e, zbijeno


Ekran vodi~a: Poluvodljivi sloj na vodi~u
Izolacija: XLPE
Ekran izolacije: Poluvodljivi sloj na izolaciji
Elektri~na za{tita/ekran: od bakrenih `ica
Separator: toplinska izolacija, poliesterska vrpca
Vanjski pla{t: PVC
Nosivo u`e: ^eli~no pocin~ano u`e 50 mm2,
za{ti}eno s PE oblogom

1.
2.
3.
4.
5.
6.
7.
8.

Conductor: aluminium rope, compacted


Conductor screen: semi-conductive layer over conductor
Insulation: XLPE
Insulation screen: semi-conductive layer over insulation
Electric protection/screen: of copper wire
Separator: thermal insulation, polyester tape
External sheath: PVC
Supporting rope: Galvanised steel rope 50 mm2,
protected with PE jacket

1
8

MJESTO I PODRU^JE UPORABE

PLACE AND FIELD OF APPLICATION

Na stupove zra~ne mre`e. Djelomi~no u zemlju, kanale ili na


konzole kod prijelaza sa ili na zra~nu mre`u.
Kao distribucijski kabel u ruralnim mre`ama. Kao spojni kabel
za industrijske pogone.

On overhead network pillars. Partially in earth, ducts or on


cable trays when transferring from or to overhead network.
As distributive cable in urbane networks. As connective cable
for industrial plants.

15
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

Promjer
kabela /
Cable
Diameter

Promjer nosivog
u`eta /
Supporting
Rope Diameter

Promjer
snopa /
Bundle
Diameter

Te`ina
snopa /
Bundle
Weight

Najmanji polumjer
savijanja /
Minimal Bending
Radius

mm

kg/km

mm

58
60
62
66
69
72
76

2200
2400
2550
2900
3300
3650
4450

690
720
740
790
830
860
910

mm

mm

mm

mm/mm

3x1x25/16+1x50
3x1x35/16+1x50
3x1x50/16+1x50
3x1x70/16+1x50
3x1x95/16+1x50
3x1x120/16+1x50
3x1x150/25+1x50

6,1
7,2
8,3
10,3
11,3
12,7
14,1

3,4
3,4
3,4
3,4
3,4
3,4
3,4

22
23
25
27
28
30
32

9/12
9/12
9/12
9/12
9/12
9/12
9/12

5.4.2. Izmjere i te`ine XHP 48/0-A 12/20/24 kV

5.4.2. Sizes and weights XHP 48/0-A


Promjer
kabela /
Cable
Diameter

Promjer nosivog
u`eta /
Supporting
Rope Diameter

Promjer
snopa /
Bundle
Diameter

Te`ina
snopa /
Bundle
Weight

Najmanji polumjer
savijanja /
Minimal Bending
Radius

mm

kg/km

mm

69
71
75
78
81
85

2800
2900
3400
3800
4300
5100

830
850
900
930
970
1000

mm

mm

mm

mm/mm

3x1x35/16+1x50
3x1x50/16+1x50
3x1x70/16+1x50
3x1x95/16+1x50
3x1x120/16+1x50
3x1x150/25+1x50

7,2
8,3
10,3
11,3
12,7
14,1

5,5
5,5
5,5
5,5
5,5
5,5

28
29
31
32
33
35

9/12
9/12
9/12
9/12
9/12
9/12

3x1x50/16+1x50
3x1x70/16+1x50
3x1x95/16+1x50
3x1x120/16+1x50
3x1x150/25+1x50

5.4.3. Sizes and weights XHP 48/0-A

20,8/36/42 kV

Nazivni presjek
Promjer
kabelskog snopa /
vodi~a /
Nominal Cross-section Diameter of
of Cable Bundle
Cable Conductor
mm2
mm

8,3
10,3
11,3
12,7
14,1

12/20/24 kV

Debljina
izolacije /
Insulation
Thickness

mm2

5.4.3. Izmjere i te`ine XHP 48/0-A

6/10/12 kV

Debljina
izolacije /
Insulation
Thickness

mm2

Nazivni presjek
Promjer
kabelskog snopa /
vodi~a /
Nominal Cross-section Diameter of
of Cable Bundle
Cable Conductor

WORKS

5.4.1. Sizes and weights XHP 48/0-A

5.4.1. Izmjere i te`ine XHP 48/0-A 6/10/12 kV


Nazivni presjek
Promjer
kabelskog snopa /
vodi~a /
Nominal Cross-section Diameter of
of Cable Bundle
Cable Conductor

CABLE

20,8/36/42 kV

Debljina
izolacije /
Insulation
Thickness
mm

Promjer
kabela /
Cable
Diameter
mm

Promjer nosivog
u`eta /
Supporting
Rope Diameter
mm/mm

Promjer
snopa /
Bundle
Diameter
mm

Te`ina
snopa /
Bundle
Weight
kg/km

Najmanji polumjer
savijanja /
Minimal Bending
Radius
mm

8,8
8,8
8,8
8,8
8,8

35
37
38
39
41

9/12
9/12
9/12
9/12
9/12

86
92
93
96
100

4300
4750
5100
5500
6250

990
1050
1080
1100
1150

Napomena:
1. Nosivo ~eli~no pocin~ano u`e je prekidne ~vrsto}e od
najmanje 72,11 kN modula elasti~nosti 17500
daN/mm2.
2. Kabeli mogu biti izra|eni s vodonepropustnom
izvedbom elektri~ne za{tite, a kabelski snop ima oznaku XHE 49/0-A (EB-AXCeWnp St).

Remark:
1. Supporting galvanised steel rope of minimal tensile
strength 72,11 kN, and elasticity module 1750 daN/mm2.
2. Cables can be manufactured with watertight construction of electric protection, and cable bundle designation is XHE 49/0-A (EB-AXCeWnp St).

16
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

XLPE-Ay TIP 23, XLPE-Ay TIP 27

5.5. IZOLIRANI SREDNJENAPONSKI NADZEMNI VOD

5.5. INSULATED MEDIUM VOLTAGE OVERHEAD INSULATED CONDUCTOR

Standardi: SFS 5791

Standards: SFS 5791

Nazivni napon: U0/U=12/20 kV


Najvi{i napon mre`e: Um=24 kV
Ispitni napon: Ui=24 kV

Nominal voltage: U0/U=12/20 kV


Max.network voltage: Um=24 kV
Test voltage: Ui=24 kV

OPIS KONSTRUKCIJE

CONSTRUCTION DESCRIPTION

1. Vodi~: u`e iz aluminijske legure AlMgSi


2. Izolacija: XLPE, otporan na atmosferilije

1. Conductor: rope of aluminium alloy, AlMgSi


2. Insulation: XLPE, resistant to weathering factors

MJESTO I PODRU^JE UPORABE

PLACE AND FIELD OF APPLICATION

Za izvedbu nadzemnih izoliranih distribucijskih mre`a nazivnih


napona 6/10 kV i 12/20 kV najvi{eg napona mre`e 24 kV.
Osobito prihvatljivo rje{enje izvedbe zra~ne mre`e kroz
{umovita podru~ja radi umanjene {irine prosjeka {ume i ni`ih
tro{kova izgradnje i odr`avanja nadzemne mre`e u odnosu na
mre`u s golim vodi~ima.

For overhead insulated distributive networks of nominal


voltages 6/10 kV and 12/20 kV and maximal network voltage
24 kV.
Specially suitable solution for construction of overhead
networks in woody areas due to reduced width of cutting
through the wood and lower costs of construction and
maintenance as related to the networks with bare conductors.

17
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

5.5.1. Izmjere i te`ine XLPE-Ay TIP 23, XLPE-Ay TIP 27

CABLE

WORKS

5.5.1. Sizes and weights XLPE-Ay Type 23, XLPE-Ay Type 27

Nazivni presjek /Najmanji broj `ica / Promjer vodi~a /


Debljina izolacije /
Promjer preko izolacije /
Te`ina izoliranog vodi~a /
Nominal
Minimal
Conductor
Insulation Thickness
Diameter over Insulation
Insulated Conductor Weight
TIP 23 / Type 23 TIP 27 / Type 27 TIP 23 / Type 23 TIP 27 / Type 27 TIP 23 / Type 23 TIP 27 / Type 27
Cross-section
Number of Wires
Diameter
mm2

mm

mm

mm

mm

mm

kg/km

kg/km

35
50
70
95
120
150
185

7
7
7
7
19
34
34

6,9
8,0
9,6
11,3
12,7
14,1
15,7

2,3
2,3
2,3
2,3
2,3
2,3
2,3

2,7
2,7
2,7
2,7
2,7
2,7
2,7

11,9
13,0
14,7
16,3
17,7
19,1
20,7

12,7
13,8
15,4
17,1
18,5
19,9
21,5

190
230
300
385
465
560
670

200
245
325
410
490
580
700

5.5.2. Technical data XLPE-Ay Type 23, XLPE-Ay Type 27

5.5.2. Tehni~ki podaci XLPE-Ay TIP 23, XLPE-Ay TIP 27

Nazivni presjek / Modul elasti~nosti / Najmanja prekidna sila / Otpor vodi~a na 200C / Nazivno stujno optere}enje1 / Struja kratkog spoja2 /
Nominal
Elasticity
Minimal
Conductor
Nominal
Short
Cross-section
Module
Tensile Strength
Resistance at 20C
Current ratings1
Circuit Current2

mm2

N/mm2

kN

Ohm/km

kA

35
50
70
95
120
150
185

60 000
60 000
60 000
60 000
57 000
57 000
57 000

9,6
13,5
18,4
26,0
32,7
41,1
50,7

0,986
0,720
0,493
0,363
0,288
0,236
0,187

195
245
300
370
425
495
570

3,20
4,35
6,85
8,90
11,70
14,50
18,00

Strujno optere}enje izra~unato je na osnovu:


spec. topl. otpor XLPE 3,50Km/W
temp. okoline 300C
najvi{a temp. vodi~a 900C
2
Dozvoljena struja kratkog spoja izra~unata na osnovu:
temp. vodi~a na po~etku kratkog spoja 300C
temp. vodi~a u kratkom spoju najvi{e 2000C
trajanje kratkog spoja 1 sek
za drugo vrijeme kratkog spoja vrijedi
Ik=Ik1x1/ t (sek)
gdje je:
Ik1 - struja kratkog spoja prema tablici 5.5.2.
t - trajanje kratkog spoja u sekundama

Current ratings calculation based upon:


spec.thermal resistance XLPE 3,5K.m/W
ambient temperature 30C
max.conductor temperature 90C
Permissible short circuit current calculation based upon:
conductor temperature at short circuit start 30C
conductor temperature at short circuit max.200C
short circuit duration 1 sec.
for different short circuit duration is valid
Ik = Ik1x1/t (sec)
where:
Ik1 - short circuit current for 1 second acc. to
Table 5.5.2
t
- duration of short circuit in seconds

18
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

XHEh 91, XHEh 91-A

5.6. ENERGETSKI KABELI S XLPE IZOLACIJOM, DODATNOM ELEKTRI^NOM ZA[TITOM I VANJSKIM


POLUVODLJIVIM PLA[TOM

5.6. POWER CABLES WITH XLPE INSULATION, ADDITIONAL ELECTRIC PROTECTION AND EXTERNAL SEMICONDUCTIVE SHEATH

Standardi: HRN HD 620 S1


IEC 60 502-2

Standards: HRN HD 620 S1


IEC 60 502-2

Nazivni napon: U0/U=6/10 kV 12/20 kV 20,8/36 kV


Najvi{i napon mre`e: Um=12 kV 24 kV 42 kV
Ispitni napon: Ui=15 kV 30 kV 52 kV

Nominal voltage: U0/U=6/10 kV 12/20 kV 20,8/36 kV


Max.network voltage: Um=12 kV 24 kV 42 kV
Test voltage: Ui=15 kV 30 kV 52 kV

OPIS KONSTRUKCIJE

CONSTRUCTION DESCRIPTION

Vodi~: bakreno ili aluminijsko u`e, zbijeno


Ekran vodi~a: Poluvodljivi sloj na vodi~u
Izolacija: XLPE
Ekran izolacije: Poluvodljivi sloj na izolaciji
Elektri~na za{tita/ekran: od bakrenih `ica, vodonepropusna izvedba
6. Pla{t: poluvodljivi PE
7. Dodatna elektri~na za{tita: od pokositrenih bakrenih `ica
(1 ili 2 sloja)

1.
2.
3.
4.
5.

Conductor: copper or aluminium rope, compacted


Conductor screen: semi-conductive layer over conductor
Insulation: XLPE
Insulation screen: semi-conductive layer over insulation
Electric protection/screen: of copper wires, watertight
construction
6. Sheath: semi-conductive PE
7. Additional electric protection: of tinned copper wires
(1 or 2 layers)

1.
2.
3.
4.
5.

MJESTO I PODRU^JE UPORABE

PLACE AND FIELD OF APPLICATION

U zemlju, kanale, na konzole, gdje se ne o~ekuju mehani~ka


o{te}enja. Konstruiran za umjerena mehani~ka vla~na
naprezanja. Kao podzemni distributivni ili spojni kabel u
podru~jima s vrlo lo{om vodljivo{}u zemlji{ta, za za{titu
elektroenergetskih postrojenja od prenapona izazvanih
udarima groma ili drugim kvarovima na visokonaponskoj
prijenosnoj mre`i.

In earth, ducts, on cable trays, where no mechanical damages


are expected. Constructed for moderate mechanical tensile
strains.
As underground distributive or connecting cable in areas with
very low ground conductivity, for protection of electric power
plants from over-voltages caused by lightning or other failures
at high-voltage transmission network.

TEHNI^KI I DRUGI PODACI


Dodatna elektri~na za{tita dimenzionira se ovisno o zahtjevima
naru~itelja. Svi ostali podaci kao za kabele tipa XHE 49 i XHE
49-A.

TECHNICAL AND OTHER DATA


Additional electric protection is rated in dependence on the
request of the client. All other data are the same as for cable
types XHE 49 and XHE 49-A.

19
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

XHE 49/24, XHE 46/29

5.7. ENERGETSKI PODMORSKI KABEL S XLPE IZOLACIJOM, TRO@ILNI S ARMATUROM OD ^ELI^NIH


@ICA, VODONEPROPUSNE IZVEDBE

5.7. SUBMARINE POWER CABLE WITH XLPE INSULATION, THREE-CORE, WITH ARMOUR OF STEEL WIRES,
IN WATERTIGHT CONSTRUCTION

5.8. ENERGETSKI PODMORSKI KABEL S XLPE IZOLACIJOM, JEDNO@ILNI S ARMATUROM OD ALUMINIJSKE LEGURE AlMgSi, VODONEPROPUSNE IZVEDBE

5.8. SUBMARINE POWER CABLE WITH XLPE INSULATION, SINGLE-CORE, WITH ARMOUR OF ALUMINIUM
ALLOY AlMgSi IN WATERTIGHT CONSTRUCTION

Standardi: HEP - Bilten broj 100


HRN HD 620 S1
IEC 60 502-2
Nazivni napon: U0/U=6/10 kV 12/20 kV 20,8/36 kV
Najvi{i napon mre`e: Um=12 kV 24 kV
Ispitni napon: Ui=15 kV 30 kV 52 kV

Standards: HEP - Bilten number 100


HRN HD 620 S1
IEC 60 502-2
Nominal voltage: U0/U=6/10 kV 12/20 kV 20,8/36 kV
Max.network voltage: Um=12 kV 24 kV
Test voltage: Ui=15 kV 30 kV 523 kV

OPIS KONSTRUKCIJE

CONSTRUCTION DESCRIPTION

Vodi~: bakreno u`e, zbijeno, vodonepropusno


Ekran vodi~a: Poluvodljivi sloj na vodi~u
Izolacija: XLPE
Ekran izolacije: Poluvodljivi sloj na izolaciji
Elektri~na za{tita/ekran: od bakrenih `ica (jedno`ilni) ili
bakrene trake (tro`ilni), uzdu`no vodonepropusni
(XHE 49/...) ili uzdu`no i popre~no vodonepropusni
(XHE 46/...)
6. Unutarnji pla{t: PE-HD
7. Armatura: spec. Al okrugla (XHE 46/29) ili ~eli~na okrugla
`ica (XHE 49/24) vodonepropustne izvedbe
8. Vanjski pla{t: PE-HD

1.
2.
3.
4.
5.

Conductor: copper rope, compacted, watertight


Conductor screen: semi-conductive layer over conductor
Insulation: XLPE
Insulation screen: semi-conductive layer over insulation
Electric protection/screen: made of copper wires (single-core)
or of copper strips (three-core), longitudinally
watertight (XHE 49/...) or longitudinally and
transversally watertight (XHE 46/...)
6. Inner sheath: PE-HD
7. Armour: special aluminium (XHE 46/29) or steel (XHE
49/24) round wire, in watertight construction
8. External sheath: PE-HD

1.
2.
3.
4.
5.

MJESTO I PODRU^JE UPORABE

PLACE AND FIELD OF APPLICATION

Kao podmorski distributivni ili spojni kabel.

As submarine distributive or connecting cable.

TEHNI^KI I DRUGI PODACI


Ovisno o zahtjevima naru~itelja i uvjetima primjene, kao posebna tehni~ka specifikacija.

TECHNICAL AND OTHER DATA


In dependence on the buyer's requests and application conditions, as separate Technical specification.

20
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

6. STRUJNA OPTERE]ENJA

6. CURRENT RATINGS

6.1. STRUJNO OPTERE]ENJE KABELA

6.1. CURRENT RATINGS OF CABLES

Elektri~na struja protjecanjem kroz vodi~e kabela razvija


toplinu {to uzrokuje isu{enje okolnog zemlji{ta te dovodi do
mogu}eg toplinskog kolapsa kabela. S tog razloga potrebno je
ograni~iti veli~inu struje protjecanu kabelom ovisno o uvjetima
pogona u kojem kabel radi. Dopu{teno strujno optere}enje
kabela izra~unato je prema IEC 287 pri ~emu je uva`eno
slijede}e:
temperatura zemlje 200C
temperatura zraka 300C
temperatura vodi~a 900C

The temperature developed by electric current streaming


through cable conductors, causing exsiccation of surrounding
ground, may be the reason of a possible thermal collapse of
cables. Because of that, it is necessary to limit the amount of
current streaming through the cable, in dependence on the
operating plant conditions of cable. Permitted current ratings
of cables is calculated acc. to IEC 287, considering the
following data:
ground temperature 20C
air temperature 30C
max. conductor temperature 90C

specifi~ni
specifi~ni
specifi~ni
specifi~ni

toplinski
toplinski
toplinski
toplinski

otpor
otpor
otpor
otpor

zemlje
XLPE
PVC
PE

1,0 K x m/W
3,5 K x m/W
6,0 K x m/W
3,5 K x m/W

dubina polaganja u zemlju


razmak kabela u zemlji
razmak kabela u zraku

specific
specific
specific
specific

0,7m
0,07m
promjer kabela

ground laying depth


cable spacing in ground
cable spacing in air

6.1.1. Strujno optere}enje 6/10 kV kabela


Mjesto polaganja i
vrsta vodi~a / Place of laying
and conductor type

resistance of ground
thermal resistance of XLPE
thermal resistance of PVC
thermal resistance of PE

1,0
3,5
6,0
3,5

K x m/W
K x m/W
K x m/W
K x m/W

0,7 m
0,07 m
cable diameter

6.1.1. Current ratings 6/10 kV cables

Zemlja / Ground
Bakar /
Aluminij /
Copper
Aluminium

Zrak / Air
Bakar /
Aluminij /
Copper
Aluminium

Zemlja / Ground
Bakar / Aluminij /
Copper Aluminium

Zrak / Air
Bakar / Aluminij /
Copper Aluminium

Na~in polaganja / Way of laying


Presjek vodi~a /
Conductor cross-section
mm2

25
35
50
70
95
120
150
185
240
300
400
500

Strujno optere}enje / Current ratings


A

180
215
250
310
370
420
460
530
610
690
780
890

165
200
235
290
345
395
440
500
580
650
750
840

140
165
195
240
290
325
360
410
480
545
625
700

130
155
180
225
270
305
340
385
455
510
590
670

175
210
255
320
385
440
500
580
680
780
890
990

160
190
230
285
345
400
455
525
625
725
850
940

130
170
205
255
305
350
390
450
530
615
710
805

125
150
180
220
270
310
355
410
490
560
665
750

Te l . :

(01)

150
180
215
265
315
360
400
455
525
600

115
140
165
205
245
280
315
355
415
470

135
165
200
250
305
350
400
460
550
630

110
130
155
195
240
275
315
360
425
480

21
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

WORKS

6.1.2. Current ratings 12/20 kV cables

6.1.2. Strujno opere}enje 12/20 kV kabela


Mjesto polaganja i
vrsta vodi~a / Place of laying
and conductor type

CABLE

Bakar /
Copper

Zemlja / Ground
Aluminij /
Aluminium

Zrak / Air
Bakar /
Copper

Aluminij /
Aluminium

Na~in polaganja / Way of laying


Presjek vodi~a /
Conductor cross-section
mm2

25
35
50
70
95
120
150
185
240
300
400
500

Strujno optere}enje / Current ratings


A

170
220
255
310
370
415
450
505
575
640
700
770

160
200
240
295
350
400
440
505
585
650
750
810

135
170
195
240
385
320
360
400
460
510
580
640

125
160
185
230
270
310
345
390
455
510
600
660

Bakar /
Copper

170
200
245
300
370
420
475
550
645
730
840
930

150
175
210
255
310
360
400
455
525
590
680
845

130
155
190
235
285
330
375
430
505
570
670
755

6.1.3. Current ratings 18/30 kV and 20/35 kV cables

6.1.3. Strujno optere}enje 18/30 kV i 20/35 kV kabela


Mjesto polaganja i
vrsta vodi~a / Place of laying
and conductor type

190
220
260
320
390
450
500
570
660
760
880
1025

Zemlja / Ground
Aluminij /
Aluminium

Zrak / Air
Bakar /
Copper

Aluminij /
Aluminium

Na~in polaganja / Way of laying


Presjek vodi~a /
Conductor cross-section
mm2

35
50
70
95
120
150
185
240
300
400
500

Strujno optere}enje / Current ratings


A

200
245
305
760
415
445
490
565
630
720
805

195
230
290
350
390
430
490
570
640
730
830

155
195
235
280
315
355
390
455
510
580
650

150
185
225
270
300
335
385
450
510
585
655

230
280
350
400
470
530
595
695
780
910
1025

205
250
310
370
425
490
555
655
730
860
935

170
220
270
330
370
420
470
545
630
710
860

160
195
240
290
330
380
435
515
590
700
790

22
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

6.2. KOREKCIONI FAKTORI

6.2. CORRECTION FACTORS

Strujno optere}enje kabela u normalnom radu kroz du`e


vremensko razdoblje dano je u tablicama 6.1.1.-6.1.3.. Radi li
kabel u uvjetima koji se razlikuju od datih u 6.1. nazivno strujno
optere}enje kabela se mno`i korekcionim faktorima prema
tablicama 6.2.1. - 6.2.6.

Current ratings of cables in normal operation over a longer


time period is stated in Tables 6.1.1 - 6.1.3. If operating
conditions of a cable differ from those stated in Table 6.1, the
nominal current ratings of cables is multiplied by correction
factors acc. to Tables 6.2.1. - 6.2.6.

6.2.1. Korekcioni faktor za razli~ite temperature okoline

6.2.1. Correction factor for different ambient temperatures

Temperatura okoline, C /
Ambient temperature, C
Polaganje u zemlju / Laying in ground
Polaganje u zraku / Laying in air

10

15

20

25

30

35

40

45

50

55

60

65

70

1,07
1,15

1,04
1,12

1,00
1,08

0,96
1,04

0,93
1,00

0,89
0,96

0,85
0,91

0,80
0,87

0,76
0,82

0,71
0,76

0,65
0,71

0,60
0,65

0,53
0,58

6.2.2. Correction factor for different cable laying depths

6.2.2. Korekcioni faktor za razli~ite dubine polaganja kabela


Dubina polaganja, m / Depth of laying, m
Korekcioni faktor / Correction factor

0,50 do 0,70
1,00

0,71 do 0,90
0,90

1,11 do 1,30
0,96

1,31 do 1,50
0,95

6.2.3. Correction factor for different specific thermal


resistances of ground

6.2.3. Korekcioni faktori za razli~ite spec. toplinske


otpornosti tla
Presjek vodi~a / Conductor cross-section
mm2

0,91 do 1,10
0,98

Spec. toplinski otpor tla / Specific thermal resistance of ground


K x m/W

0,70
1,11
1,13
1,14
1,15

25
35 do 95
120 do 240
300 do 500

1,00
1,00
1,00
1,00
1,00

1,20
0,94
0,93
0,93
0,92

2
0,79
0,85
0,86
0,87

Broj kabela (sistema) / Number of cables (systems)


polo`enih u zemlju /
Spacing between cables (system)
laid in ground

2,0
0,78
0,76
0,76
0,75

2,0
0,72
0,70
0,69
0,68

3,0
0,67
0,64
0,63
0,63

6.2.4. Correction factor for different number of cables or


systems of the same cutting

6.2.4. Korekcioni faktor za razli~iti broj kabela ili sistema u


istom prokopu
Razmak izme|u kabela (sistema)

1,50
0,87
0,86
0,85
0,85

Dodir / Touch
7 cm
15 cm
25 cm

3
0,69
0,75
0,77
0,78

4
0,63
0,68
0,72
0,74

5
0,58
0,64
0,68
0,71

6
0,55
0,60
0,64
0,67

8
0,50
0,56
0,61
0,64

10
0,46
0,53
0,58
0,62

23
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

WORKS

6.2.5. Correction factors for three-core cables in air

6.2.5. Korekcioni faktori za tro`ilne kabele u zraku


Broj kabela / Number of cables

CABLE

9
2 cm

Faktori za prera~unavanje:
Kabeli polo`eni na zemlji

0,95

0,90

0,88

0,85

0,84

0,95

0,90

0,88

0,85

0,84

0,90

0,85

0,83

0,81

0,80

0,88

0,83

0,81

0,79

0,78

0,86

0,81

0,79

0,77

0,76

Conversion factor:
Cables laying on the ground

Faktor za prera~unavanje:
Kabeli polo`eni u pregradama
(cirkulacija zraka sprije~ena)
Conversion factor:
Cables laying in racks
(prevented air circulation)

= 20 cm

Broj pregrada /
Number of racks

2 cm

Conversion factor:
Cables laying on trays

1,0

0,98

0,96

0,93

0,92

1,0

0,95

0,93

0,90

0,89

1,0

0,94

0,92

0,89

0,88

1,0

0,93

0,90

0,87

0,86

1,0

0,93

0,90

0,87

0,86

2 cm

Faktor za prera~unavanje:
Kabeli polo`eni na nosa~ima ili
su pri~vr{}eni uza zid

Conversion factor:
Cables laying on supports or fastened
against wall

Faktor za prera~unavanje:
Kabeli polo`eni na policama

= 20 cm

Broj polica /
Number of trays

2 cm

Faktori za prera~unavanje:
Kabeli polo`eni na zemlji
0,90

0,84

0,80

0,75

0,73

Conversion factor:
Cables laying on the ground

Faktor za prera~unavanje:
Kabeli polo`eni u pregradama
(cirkulacija zraka sprije~ena)
Conversion factor:
Cables laying in racks
(prevented air circulation)

0,95

0,84

0,80

0,75

0,73

0,95

0,80

0,76

0,71

0,69

0,95

0,78

0,74

0,70

0,68

0,95

0,76

0,72

0,68

0,66

= 20 cm

Broj pregrada /
Number of racks

Faktor za prera~unavanje:
Kabeli polo`eni na policama
Conversion factor:
Cables laying on trays

0,95

0,84

0,80

0,75

0,73

0,95

0,80

0,76

0,71

0,69

0,95

0,78

0,74

0,70

0,68

0,95

0,76

0,72

0,68

0,66

0,95

0,78

0,73

0,68

0,66

Faktor za prera~unavanje:
Kabeli polo`eni na nosa~ima ili
su pri~vr{}eni uza zid
Conversion factor:
Cables laying on supports or fastened
against wall

= 20 cm

Broj polica /
Number of trays

24
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

6.2.6. Korekcioni faktori za jedno`ilne kabele u zraku


Broj sistema / Number of cables

CABLE

WORKS

6.2.6. Correction factors for single-core cables in air

3
2 cm

Faktori za prera~unavanje:
Kabeli polo`eni na zemlji

2 d

0,95

0,90

2 d

0,88

Conversion factor:
Cables laying on the ground
2 cm

Faktor za prera~unavanje:
Kabeli polo`eni u pregradama
(cirkulacija zraka sprije~ena)
Conversion factor:
Cables laying in racks
(prevented air circulation)

0,95

0,90

0,88

0,90

0,85

0,83

0,88

0,83

0,81

0,86

0,81

0,79
2 cm

Conversion factor:
Cables laying on trays

1,0

0,98

0,96

1,0

0,95

0,93

1,0

0,94

0,92

1,0

0,93

0,90

2 d

2 d

2 d

= 20 cm

Broj polica /
Number of trays
Faktor za prera~unavanje:
Kabeli polo`eni na policama

2 d

= 20 cm

Broj pregrada /
Number of racks

2 cm

Faktor za prera~unavanje:
Kabeli polo`eni na zemlji

Broj pregrada /
Faktori za prera~unavanje:
Number of racks
Kabeli polo`eni u pregradama
1
(cirkulacija zraka sprije~ena)
2
Conversion factor:
3
Cables laying in racks
(prevented air circulation)
6

0,92

0,89

0,88

0,92

0,89

0,88

0,87

0,84

0,83

0,84

0,82

0,81

0,82

0,80

0,79

= 20 cm

Conversion factor:
Cables laying on the ground

2 cm

1,0

0,97

0,96

0,97

0,94

0,93

0,96

0,93

0,92

0,94

0,91

0,90

0,94

0,91

0,89

Faktor za prera~unavanje:
Kabeli polo`eni na nosa~ima ili
su pri~vr{}eni uza zid

2 cm

Conversion factor:
Cables laying on supports or fastened
against wall

Conversion factor:
Cables laying on supports or fastened
against wall

2 cm

0,89

0,86

0,84

Faktor za prera~unavanje:
Kabeli polo`eni na nosa~ima ili
su pri~vr{}eni uza zid

Conversion factor:
Cables laying on trays

1
2

Faktor za prera~unavanje:
Kabeli polo`eni na policama

= 20 cm

Broj polica /
Number of trays

25
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

6.3. DOPUSTIVE STRUJE KRATKOG SPOJA

6.3. PERMITTED SHORT CIRCUIT CURRENTS

Otpornost izolacije na visoki toplinski u~inak struje kratkog


spoja odre|ena je grani~nom temperaturom vodi~a koja za
XLPE izolaciju iznosi 2500C.
Dopu{tena struja kratkog spoja faznog vodi~a kabela dodatno
je uvjetovana temperaturom vodi~a na po~etku kratkog spoja, u
pravilu 900C, i trajanjem kratkog spoja najvi{e 5 sekundi.
Dopu{tena struja kratkog spoja elektri~ne za{tite kabela
uvjetovana je temperaturom elektri~ne za{tite na po~etku
kratkog spoja, pretpostavljeno 700C, i najvi{om dozvoljenom
temperaturom bakrenih `ica ili vrpci elektri~ne za{tite,
pretpostavljeno 3500C, uz trajanje kratkog spoja najvi{e 5
sekundi.

Insulation resistance to high thermal impact of short circuit


current is determined by a limit conductor temperature, which
amount to 250C for XLPE insulation.
Permitted short circuit current of cable phase conductor is
additionally conditioned by conductor temperature at the short
circuit beginning, regularly 90C and by short circuit duration,
but not more than 5 seconds.
Permitted short circuit current of cable electric protection is
conditioned by electric protection temperature at the short
circuit beginning, of anticipated value 70C, and the highest
permitted temperature of copper wires or tapes, electric
protection, anticipated 350C, and short circuit duration of
max. 5 seconds.

6.3.1. Dopu{tena struja kratkog spoja za vodi~e kabela

6.3.1. Permitted short circuit currents for cable conductors

Presjek vodi~a /
Conductor
cross-section

Vrijeme trajanja katkog spoja (sekunde) / Short circuit duration (seconds)

0,1

0,5

0,1

Struja kratkog spoja za bakrene vodi~e /


Short circuit current for copper conductors
kA

mm2

25
35
50
70
95
120
150
185
240
300
400
500

0,2

11,4
15,9
22,7
31,8
43,1
54,5
68,1
84,0
109,0
136,2
181,6
227,0

8,2
11,2
16,1
22,5
30,5
38,5
48,1
59,4
77,0
96,3
128,4
160,5

5,1
7,1
10,2
14,2
19,3
24,4
30,5
37,6
48,7
60,9
81,2
101,0

3,6
5,1
7,2
10,1
13,7
17,3
21,6
26,6
34,6
43,2
57,6
720,0

2,5
3,5
5,0
7,0
9,6
12,1
15,2
18,7
24,2
30,3
40,4
50,5

0,2

0,5

Struja kratkog spoja za aluminijske vodi~e /


Short circuit current for aluminium conductors
kA

1,6
2,2
3,2
4,5
6,1
7,7
9,6
11,8
15,4
19,2
25,6
32,0

Za vrijeme trajanja kratkog spoja razli~itog od vrijednosti


navedenih u tablici, vrijednosti struje kratkog spoja za 1 sekundu potrebno je pomno`iti s faktorom 1/t, gdje je t vrijeme trajanja kratkog spoja u sekundama.

7,3
10,2
14,7
20,5
27,8
35,2
44,0
54,2
70,3
87,9
117,2
146,5

5,2
7,2
10,4
14,5
19,7
24,8
31,1
38,3
49,7
62,1
82,8
103,5

3,3
4,6
6,7
9,2
12,4
15,7
19,7
24,2
31,4
39,3
52,4
65,5

2,3
3,2
4,6
6,5
8,8
11,1
13,9
17,1
22,2
27,8
37,0
46,3

1,64
2,3
3,3
4,6
6,2
7,8
9,8
12,1
15,7
19,6
26,2
32,7

1,04
1,5
2,1
2,9
3,9
5,0
6,2
7,7
9,9
12,4
16,6
20,7

During short circuit duration differing from in the upper Table


stated values, the short circuit current values for 1 second are
to be multiplied by 1/t factor, where t denotes short circuit
duration in seconds.

26
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

6.3.2. Permitted short circuit current for electric protection of


cable

6.3.2. Dopu{tena struja kratkog spoja za elektri~nu za{titu


kabela

Vrijeme trajanja kratkog spoja (sekunde) / Short circuit duration (seconds)

Presjek el. za{tite / Electric protection cross-section

0,1

0,2

mm2

0,5

Struja kratkog spoja (kA) / Short circuit current (kA)

6
10
16
25
35
50

4,2
7,0
11,1
17,4
24,3
34,8

2,9
4,9
7,9
12,3
17,2
24,6

1,9
3,1
5,0
7,8
10,9
15,6

1,3
2,2
3,5
5,5
7,7
11,0

0,9
1,6
2,5
3,9
5,4
7,8

0,6
1,0
1,6
2,5
3,4
4,9

Za vrijeme trajanja kratkog spoja razli~itog od vrijednosti u


tablici, vrijednosti struje kratkog spoja za 1 sekundu potrebno je
pomno`iti s faktorom 1/t, gdje je t vrijeme trajanja kratkog spoja
u sekundama.

During short circuit duration differing from in the upper Table


stated values, the short circuit current values for 1 second is to
be multiplied by 1/t factor, where t denotes short circuit
duration in seconds.

7. ELEKTRI^NI PODACI

7. ELECTRICAL DATA

7.1. Elektri~ni otpor vodi~a

7.1. Electric resistance of conductor

Presjek vodi~a /
Conductor cross-section
Istosmjerni otpor na 200C /
Direct resistance at 20C

mm2
Ohm/km

25
Cu
Al

35

50

70

0,727 0,524 0,387


1,20 0,868 0,641

95

120

150

185

240

300

400

500

0,268 0,193 0,153 0,124 0,0991 0,0754 0,0601 0,0470 0,0366


0,443 0,320 0,253 0,206 0,164 0,125 0,100 0,0778 0,0605
Direct resistance of conductor at temperature J different from
20C is calculated acc. to equation:

Istosmjerni otpor vodi~a na temperaturi J razli~itoj od 200C


izra~unava se prema izrazu:

RJ=R20 1+a20(J-20) Ohm/km

RJ=R201+a20(J-20) Ohm/km
gdje je:

where:

R20 - vrijednost otpora vodi~a iz Tablice 7.1.


a20 - temperaturni koeficijent otpora
a20 = 3,93 x 10-3 za bakar (Cu)
a20 = 4,03 x 10 -3 za aluminij (Al)

R20 - value of conductor resistance of Table 7.1


a20 - temperature coefficient of resistance
a20= 3,93 x 10-3 for copper (Cu)
a20=4,03 x 10-3 for aluminium (Al)
7.2. Operating Capacity

7.2. Pogonski kapacitet

Nazivni napon kabela U0/U / Nominal voltage of cables, U0/U

Presjek vodi~a /
Conductor cross-section
mm2

6/10 kV

25
35
50
70
95
120
150
185
240
300
400
500

0,208
0,236
0,246
0,284
0,365
0,342
0,371
0,401
0,450
0,492
0,551
0,629

12/20 kV

18/30 kV

20/35 kV

Kapacitet (mF/km) / Capacity (mF/km)

0,149
0,161
0,175
0,202
0,215
0,233
0,251
0,272
0,302
0,327
0,376
0,413

0,126
0,137
0,156
0,166
0,178
0,190
0,205
0,226
0,243
0,277
0,303

0,118
0,127
0,144
0,153
0,164
0,175
0,188
0,207
0,223
0,253
0,276

27
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

Radni kapacitet kabela ovisi o geometrijskim veli~inama kabela


i relativnoj konstanti izolacije tj:
CR =

WORKS

Operating capacity of cables depends on cable geometric size


and insulation constant, i.e.:

mF/km

18ln D
d

CABLE

CR =

gdje je:

18ln D
d

mF/km

where:

e =2,5 for XLPE

r =2,5 za XLPE
D =promjer preko izolacije (mm)
d =promjer preko vodi~a uklju~ivo poluvodljivi sloj (mm)

D=diameter over insulation (mm)


d=diameter over conductor, incl. semi-conductive layer (mm)
7.3. Operating inductance

7.3. Pogonski induktivitet

Nazivni napon kabela U0/U / Nominal voltage of cables, U0/U

Presjek vodi~a /

6/10 kV

Conductor cross-section

12/20 kV

mm2

18/30 kV

20/35 kV

Induktivitet (mH/km) / Inductance (mH/km)

25
35
50
70
95
120
150
185
240
300
400
500

0,44
0,42
0,40
0,38
0,37
0,36
0,35
0,34
0,33
0,33
0,32
0,32

0,65
0,63
0,61
0,59
0,57
0,55
0,54
0,53
0,52
0,51
0,49
0,8

0,46
0,45
0,43
0,41
0,39
0,37
0,36
0,35
0,34
0,33
0,31
0,30

0,68
0,66
0,64
0,61
0,59
0,58
0,56
0,55
0,53
0,52
0,50
0,49

0,51
0,49
0,46
0,43
0,41
0,40
0,39
0,39
0,36
0,35
0,34
0,33

0,69
0,66
0,63
0,61
0,52
0,57
0,56
0,54
0,53
0,51
0,50

0,51
0,49
0,47
0,44
0,43
0,42
0,40
0,38
0,37
0,36
0,34

0,76
0,73
0,69
0,67
0,65
0,63
0,61
0,59
0,58
0,55
0,52

0,53
0,50
0,47
0,45
0,44
0,43
0,41
0,39
0,38
0,37
0,36

Podaci u Tablici 7.3. dati su za nearmirane kabele. Za armirane


tro`ilne kabele 6/10 kV potrebno je vrijednosti iz stupca
pomno`iti s faktorom 1,30.

Data in Table 7.2 are stated for unarmoured cables. For


armoured three-core cables 6/10 kV, values of column
are
to be multiplied by 1,30 factor.

7.4. KAPACITIVNA STRUJA KABELA

7.4. CAPACITIVE CURRENT OF CABLES

Odre|uje se prema izrazu:


Ic=U0 x w x C x 10-3 A/km/fazi
gdje je:
U0 - fazni napon (kV)
w - kru`na frekvencija (1/s)
C - kapacitet kabela (mF/km) prema Tablici 7.2.

It is determined by equation:
Ic=U0 x w x C x 10-3 A/km/phase
where:
U0 -phase voltage (kV)
w -angular frequency (1/s)
C -cable capacity ((F/km) acc. to Table 7.2.

7.5. IMPEDANCIJA KABELA

7.5. CABLE IMPEDANCE

Impedancija kabela je kompleksna veli~ina i ovisi o otporu


vodi~a, induktivnom i kapacitivnom otporu kabela. Op}enito
mo`e se dati izrazom:
/Z/=R2+(wL)2 W/km
gdje je:
R - otpor vodi~a (W/km)
w - kru`na frekvencija (1/s)
L - induktivitet kabela (m H/km) prema tablici 7.3.

Cable impedance is a complex value depending on conductor


resistance, inductive and capacitive resistance of cable.
Generally, it could be expressed by equation:
/Z/=R2+(wL)2 W/km
where:
R -conductor resistance ((/km)
w -angular frequency (1/s)
L -cable inductance (mH/km)acc. to Table 7.3.

28
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

8. ISPITIVANJE

8. TESTS

Kabeli se ispituju prema normi HRN HD 620 S1 ili standardu


IEC 60502-2 uva`avaju}i:

Cables are tested in accordance with the standard HRN HD


620 S1 or the standard IEC 60502-2 respecting) also:

8.1. RUTINSKO ISPITIVANJE

8.1. ROUTINE TESTS

Mjerenje otpora vodi~a


Naponsko ispitivanje: 2,5 U0/5 minuta
Ispitivanje parcijalnih izboja: 2
pC/2 U0
Rutinsko ispitivanje provodi se na svakoj duljini kabela

Measuring of conductor resistance


Voltage test: 2,5 U0/5 min.
Partial discharge test:2 pC/2 U0
Routine tests are performed at each cable length.

8.2. SPECIJALNO ISPITIVANJE

8.2. SPECIAL TESTS

Provjera vodi~a
Provjera debljine izolacije, poluvodljivih slojeva i pla{ta
Mjerenje `ice i/ili vrpce u el. za{titi i armaturi
Mjerenje vanjskog promjera
Provjera umre`enja istezanjem
Specijalno ispitivanje provodi se na jednoj duljini kabela iz
svake proizvodne serije istog tipa i presjeka kabela ali ne vi{e od
10% ukupnog broja duljina.

Conductor check
Insulation thickness, semi-conductive layers and sheath check
Measuring of wire and/or tape in electric protection and
armour
Measuring of outer diameter
Cross-linking check by elongation
Special tests are performed at one cable length of each production series of the same type and cross-section of a cable,
but not more than 10 % of a total lengths number.

8.3. TIPSKO ISPITIVANJE

8.3. TYPE TESTS

8.3.1. Elektri~na ispitivanja


Ispitivanje parcijalnih izbijanja
Ispitivanje savijanjem nakon ~ega slijedi ispitivanje parcijalnih
izbijanja
Mjerenje tg d
Ispitivanje cikli~kim grijanjem nakon ~ega slijedi ispitivanje
parcijalnih izbijanja
Ispitivanje udarnim naponom nakon ~ega slijedi naponsko
ispitivanje
Naponsko ispitivanje 3U0, 4 sata

8.3.1. Electric tests


Partial discharge test
Bending test followed by partial discharge test
Measuring of tg d
Cyclic heating test followed by partial discharge test
Impulse voltage test followed by voltage test
Voltage test 3 U0, 4 hours

8.3.2. Neelektri~na ispitivanja


Mjerenje mehani~kih svojstava izolacije i pla{teva prije i nakon starenja
Termoplasti~nost pla{teva
Ispitivanje otpornosti na savijanje pri niskim temperaturama
Starenje na uzorku kompletnog kabela
Ispitivanje uzdu`ne vodonepropusnosti
Ispitivanje otpornosti na {irenje plamena (za kabele tipa TG)
prema IEC 60332-3
Ostala ispitivanja na izolaciji i pla{tu kabela: gubitak mase,
toplotni udar, umre`enje, upijanje vode, skupljanje na povi{enoj temperaturi, sadr`aj ~a|e, odvajanje poluvodljivih slojeva
od izolacije

8.3.2. Unelectric tests


Measuring of mechanical properties of insulation and sheaths before and after ageing
Thermoplasticity of sheaths
Bending resistance test at low temperatures
Ageing at complete cable sample
Longitudinal watertightness test
Test of resistance to fire propagation (for cable types TG)
acc. to IEC 60332-3
Other tests at cable insulation and sheath: mass loss, thermal
impact, cross-linking, water absorption, shrinking at higher
temperature, soot contents, separation of semi-conductive
layers from insulation

8.4. ISPITIVANJE POSLIJE POLAGANJA

8.4. TESTS AFTER LAYING

Ispitivanje kabela nakon polaganja izvodi se na potpuno


instaliranom kabelu zajedno sa svim spojnim i zavr{nim
ure|ajima na novoj instalaciji, pri ~emu se provodi:

Testing of cables after laying is performed at fully installed


cable, complete with all connecting and final devices at new
installation, including:

29
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

8.4.1. Naponsko ispitivanje izolacije


Istosmjernim naponom 4U0/15 minuta izme|u vodi~a i elektri~ne za{tite kabela
ili
Izmjeni~nim naponom industrijske frekvencije 2U0/60 minuta
ili
Izmjeni~nim naponom 0,1 Hz visine 3U0/60 minuta

8.4.1. Voltage test of insulation


By direct voltage 4U0/15 minutes between the conductor and
the electrical protection of the cable
or
By alternating voltage of industrial frequency 2U0/60 minutes
or
By alternating voltage 0,1 Hz level 3U0/60 minutes

8.4.2. Naponsko ispitivanje pla{ta


Istosmjernim naponom 5 kV/15 minuta
Naponsko ispitivanje pla{ta izvodi se radi provjere o{te}enosti
pla{ta nastale pri skladi{tenju ili polaganju.

8.4.2. Voltage test of sheath


By direct voltage 5 kV/15 minutes
Voltage test of a sheath is performed by way of checking the
possible cable damage during storage or laying.

30
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

9.1. DIMENZIJE BUBNJEVA ZA PAKIRANJE

9.1. SIZES OF PACKING DRUMS

Kabeli se namataju na drvene ili metalne bubnjeve u


standardnim duljinama 1000 m ili prema zahtjevu. Nazivni broj
bubnja ujedno je i promjer stranice iskazan u dm.
Osnovni podaci bubnjeva su u skladu s njema~kom normom
DIN 46 391.

Cables are wound at wooden or metal drums in standard


lengths of 1000 m or upon request. Nominal drum number is
at the same time the side diameter expressed in dm.
Basic drum data are in accordance with German standard
DIN 46391.

Slika 1. Oblik drvenih bubnjeva "BD"

Picture 1. Shape of wooden drums "BD"

9. PACKING

9. PAKIRANJE

b
B

9.1.1. Osnovne zna~ajke drvenih bubnjeva


Veli~ina bubnja
Size of drum

9.1.1. Basic features of wooden drums

Promjer bubnja "D" Promjer jezgre bubnja "d" [irina bubnja "B" [irina izme|u stranica "b" Te`ina bubnja (pribli`no)
Drum weight (approx.)
Diameter of drum "D" Diameter of drum core "d" Width of drum "B" Width between sides "b"
mm
mm
mm
mm
kg

6
7
8
9
10
12
14
16
18
20
201
22
221
25
251
28
30

630
710
800
900
1000
1250
1400
1600
1800
2000
2000
2240
2240
2500
2500
2800
3000

315
355
400
450
500
630
710
900
1120
1000
1250
1120
1400
1250
1500
1800
1800

440
525
575
575
685
810
940
1090
1355
1355
1355
1355
1355
1355
1355
1635
1635

315
400
450
450
560
630
750
900
1120
1120
1120
1120
1120
1120
1120
1400
1400

24
30
38
45
56
102
195
255
433
462
513
664
733
833
869
1141
1241

31
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

9.2. Pakiranje u ovisnosti o polumjeru savijanja kabela


Promjer kabela /
Cable diameter

SD
12

SD
14

SD
16

WORKS

9.2. Packing in dependence to cable bending radius

Tip i veli~ina bubnja / Type and size of drum


SD
SD
SD
SD
SD
SD
18
20
201
22
221
25

mm

SD
251

SD
28

SD
30

Duljina pakiranja (m) / Packing lenght (m)


1554
1457
1301
1115
1091
953
929
904
777
753
729
615
620
597
493
497
476
480
485
389
370

2100
1840
1811
1567
1538
1311
1282
1112
1084
1055
900
873
846
852
711
686
691
665
541
544
522
525
501
504
419
399
401
380
382
384

2135
2056
1807
1734
1659
1435
1405
135
1134
1106
1078
1049
900
874
849
822
796
800
643
646
623
600
602
578
581
448
450
451
431
433
413
414
416
395
397
305
299
290
291
275
275
270

2123
2031
1992
1741
1704
1617
1391
1355
1319
1153
1120
1087
1054
1020
874
845
848
818
788
791
632
635
608
611
613
586
588
561
453
455
432
434
435
412
413
415
392
393
394
395
285
286
286
286

2226
2185
2081
1850
1809
1592
1605
1565
1361
1323
1283
1293
1107
1115
1078
1040
913
879
885
850
855
738
707
711
679
683
687
655

2412
2359
205
2124
1880
1830
1779
1556
1568
1519
1366
1321
1274
1283
1092
1098
1058
1062
1068
892
897
857
862
867
826
712
716
680
683
687
649
653

/
D
2x
1 xD
Rs 12
a s
nj R
ja s
vi iu
sa rad
r
je g
m in
lu end
Po B

963
798
775
671
648
552
559
537
448
453
432
353
356
337
340
269

/
xD
9 D
Rs 9x
a s
nj R
ja s
vi iu
sa rad
r
je g
m in
lu end
Po B

20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79

CABLE

2092
1985
1937
1684
1639
1649
1413
1371
1329
1287
1293
1085
1090
1051
1012
1017
833
836
801
804
808
772
775
615
617
619
589
591
593
562
563
565
429
431
432
433
407
408
409
411
412
374
375
376
377
378
270
270
271

2116
2053
2069
1820
1833
1773
1541
1552
1494
1504
1290
1298
1306
1251
1112
1062
1068
1074
1023
1029
901
856
860
864
817
821
826
711
670
673
676
679
682

2157
1889
1834
1845
1789
1543
1551
1500
1447
1280
1232
1238
1190
1196
994
998
955
959
963
918
784
746
748
751
712
715
717
720
564
566
568
570
536
537
539
541
506
493
494
397
398
371
372
373
374
375

2162
1855
1862
1808
1752
1759
1482
1432
1437
1387
1392
1341
1149
1153
1108
1112
1067
1070
1074
1028
859
821
823
825
827
788
790
792
753
732
734
593
562
563
564
565
533
535

2059
2061
2007
1948
1952
1895
1654
1597
1603
1558
1559
1508
1510
1511
1245
1249
1252
1204
1207
1128
1131
1130
1089
1091
907
908
874
875

32
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

10. POLAGANJE I SPAJANJE KABELA

10. LAYING AND CONNECTING OF CABLES

10.1. OP]ENITO O POLAGANJU

10.1. GENERALLY ON LAYING

Polaganje kabela mora biti pa`ljivo da ne do|e do o{te}enja


kabela ni za vrijeme polaganja niti kasnije u pogonskom radu. S
tog razloga preporu~uje se pridr`avati slijede}eg:
Polagati kod temperature koja ne}e uzrokovati o{te}enje
kabela ni ugroziti sigurnost ljudi i opreme
Razvla~enje kabela izvoditi ure|ajem za razvla~enje s
kontrolom vu~ne sile
Kabel kod polaganja u zemlju polagati uvijek na pripremljenu
posteljicu; ne smije se vu}i po zemlji, pogotovo ne po kamenitom tlu
Materijali za posteljicu ne smiju imati agresivni utjecaj na pla{t
kabela
Kabel ne savijati ispod najmanjeg dozvoljenog polumjera
savijanja
Kabelski rov ne zatrpavati grubim kamenjem
Iznad kabela postaviti {titnike i upozoravaju}u vrpcu
Krajeve kabela obavezno zatvoriti vodonepropusnim kapama

Cables are to be laid carefully, to avoid cable damage either


during laying or later in operating conditions. Because of that,
one should respect the following:
Cables are to be laid at the temperature which won't cause
cable damage nor endanger the safety of people or equipment
Cable stretching should be performed by a stretching device
equipped by tensile strength control
When laid into the ground, the cable is always to be laid at
prepared bedding; it must not be pulled over the ground,
specially not over stony terrain
Bedding material shouldn't act aggressively upon cable sheath
Permitted bending radius to be respected.
Cable trench must not be covered up with rough stones
Protections and warning tapes should be put over the cables
Cable ends should be obligatorily closed by watertight caps.

10.2. TEMPERATURA POLAGANJA

10.2. LAYING TEMPERATURE

Kabeli s PVC pla{tom mogu se polagati na temperaturi okoline


do -50C, dok se kabeli s PE pla{tom mogu polagati i kod temperatura do -200C.
Za polaganje kod temperatura ni`ih od navedenih potrebno je
provesti zagrijavanje kabela na temperaturu iznad +50C, jednom od za to poznatih metoda i odr`avati tu temperaturu najmanje 24 sata prije polaganja.

PVC sheathed cables could be laid at ambient temperature up


to -5C, whereupon the PE sheathed cables could be laid even
at -20C temperature.
When laying at lower temperatures than those stated, cables
should be warmed up to the temperature of over +5C
applying one of the adequate known methods and that
temperature is to be maintained for at least 24 hours before
laying.

10.3. POLUMJER SAVIJANJA

10.3. BENDING RADIUS

Kod polaganja potrebno je pridr`avati se slijede}ih vrijednosti:


tijekom polaganja
jedno`ilni kabel Rs1
5D
tro`ilni kabel Rs1
2D
kabel polo`en, savijen preko forme
jedno`ilni Rs1
2D
tro`ilni Rs9
D
gdje je:
D - vanjski promjer kabela /mm/

The following values are to be respected at laying:


during laying

single-core cable Rs15D

three-core cable Rs12D


laid cable, bended over the form

single-core cable Rs12D

three-core cable Rs9D


where:
D -outer cable diameter /mm/

10.4. SILA RAZVLA^ENJA

10.4. TRACTIVE FORCE

Dopu{tena sila razvla~enja kabela ne smije prije}i kod


primjene vu~ne ~arapice
Pd 5 D2 kN
primjene vu~ne stezaljke
vodi~ Cu
Pd n x q x 50 kN
vodi~ Al
Pd n x q x 30 kN
gdje je:
D - promjer kabela (mm)
n - broj vodi~a u kabelu (ili broj kabela)
q - presjek vodi~a (mm2)

Permitted tractive force of a cable must not exceed at


cable stocking application
Pd 5 D2 kN
cable grip application
x q x 50 kN
Conductor Cu
Pdn
x q x 30 kN
Conductor Al
Pdn
where:
D -cable diameter (mm)
n -number of conductors in cable (or number of cables)
q -conductor cross-section (mm2)

33
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

CABLE

WORKS

Preporu~a se razvla~enje kabela vu~nom ~arapicom. Dio kabela


obuhva}en vu~nom ~arapicom nakon zavr{enog razvla~enja
obavezno odsje}i.

It is recommended to pull the cables by using a cable stocking.


The part of the cable covered by the cable stocking should be
obligatorily cut off after completed traction.

10.5. SPAJANJE I ZAVR[AVANJE KABELA

10.5. CONNECTING AND TERMINATING OF CABLES

Najpoznatiji na~ini spajanja i zavr{avanja srednjenaponskih


kabela s XLPE izolacijom su:
primjena predoblikovanih spojnica i kabelskih zavr{etaka
omatanje vrpcama posebno izra|enim za ove namjene
Potrebno je po{tivati upute proizvo|a~a kod izvedbe spojnica i
kabelskih zavr{etaka.
Elka, na zahtjev, uz isporuku kabela osigurava i:
isporuku spojnica i kabelskih zavr{etaka za sve tipove kabela iz
svog proizvodnog programa,
monta`u spojnica i kabelskih zavr{etaka,
isporuku i monta`u spojnog, zateznog i ovjesnog pribora za
nadzemne izolirane vodi~e i samonosive kabele,
obuku (treninge) za rad na spojnom priboru razli~itih
proizvo|a~a.

The best known ways of connecting and terminating of medium voltage cables with XLPE insulation are:
application of prefabricated junctions and cable terminations
wrapping by specially designed tapes
Producer's instructions are to be respected at junction and cable termination execution.
At request, along with the cable delivery, ELKA can secure:
delivery of junctions and cable terminations for all cable types of its production program
assembly of junctions and cable terminations
delivery and assembly of connecting, straining and suspension
accessories for overhead insulated conductors and self-supporting cables
training for operation with connecting accessory of different
producers.

34
ELKA kabeli d.o.o.,

Koledov~ina 1,

HR - 10 001

ZAGREB,

CROATIA,

Te l . :

(01)

24

82

600,

Fax.:

(01)

24

04

898

Medium voltage power cables for rated voltage up to 36 kV

Energetski srednjenaponski kabeli za napone do 36 kV

TVORNICA ELEKTRI^NIH KABELA

ELECTRIC

- 1 kV s PVC i XLPE izolacijom


- 6 kV do 36 kV s XLPE i EPDM izolacijom
- 1 kV do 36 kV s XLPE izolacijom u samonosivoj izvedbi

SAVITLJIVI I INSTALACIJSKI VODOVI I KABELI


IZOLIRANI TERMOPLASTIMA
- energetski vodovi i kabeli
- automobilski vodovi

WORKS

MANUFACTORING RANGE

PROIZVODNI PROGRAM

ENERGETSKI KABELI

CABLE

POWER CABLES
- 1 kV insulated with PVC and XLPE
- 6 kV to 36 kV insulated with XLPE and EPDM
- 1 kV to 36 kV selfsupporting cables with XLPE insulation

THERMOPLASTIC INSULATED WIRING CABLES AND WIRES


- power cables and wires
- automotive wires

SAVITLJIVI I INSTALACIJSKI VODOVI I KABELI


IZOLIRANI ELASTOMERIMA

RUBBER INSULATED WIRING CABLES AND WIRES

BRODSKI KABELI

SHIPBOARD CABLES

- s EPDM izolacijom i CR pla{tom


- te{ko gorivi, s izolacijom i pla{tom bez halogenih materijala
- vatrootporni, s izolacijom i platom bez halogenih materijala

- insulated with EPDM and sheathed with CR


- flame retardant halogen free cables
- fire-resistant halogen free cables

KABELI I KONEKTORI ZA AERODROMSKE


INSTALACIJE

CABLES AND CONNECTORS FOR AIRPORT INSTALLATIONS

TELEKOMUNIKACIJSKI KABELI

TELECOMMUNICATION CABLES

- telefonski kabeli s PE izolacijom


- telefonski kabeli s PVC izolacijom

- telephone cables with PE insulation


- telephone cables with PVC insulation

SVJETLOVODNI KABELI

FIBREOPTIC CABLES

SIGNALNO-UPRAVLJA^KI, MJERNI I KABELI ZA


INFORMATI^KE MRE@E

CONTROL, INSTRUMENT AND COMPUTER CABLES

- signalno-upravlja~ki s PVC izolacijom za napone do 1 kV


- mjerni s PE i XLPE izolacijom i PVC pla{tom
- kabeli sa svjetlovodnim i Cu vodi~em kategorije 5 za lokalne informati~ke
mre`e (LAN)

- control cables 1 kV with PVC insulation


- instrument cables insulated with PE and XLPE and PVC sheathing
- fibreoptic and copper LAN cables in cat. 5

RUDARSKI KABELI

MINING CABLES

KABELI ZA ZAVARIVANJE

WELDING CABLES

SPECIJALNI VODOVI I KABELI

SPECIAL CABLES AND WIRES

- za radne temperature od +70 C do + 160 C

- for operating temperature +70 C to +160 C

LAKIRANA @ICA

ENAMELLED WIRE

ALUMINIJSKA, ALU-^ELI^NA I U@AD OD


ALUMINIJSKIH LEGURA

ALUMINIUM, STEEL REINFORCED ALUMINIUM ROPES AND


Al-ALLOY ROPES

ZA[TITNA U@AD SA SVJETLOVODNIM NITIMA (OPGW)

OPTICAL POWER GROUND WIRE (OPGW)

^ELI^NA U@AD I PRIVEZNICE ZA DIZALICE, BRODOVE I


DRUGE NAMJENE

STEEL ROPES FOR LIFTS, CRANES, SHIPS AND OTHER


APPLICATIONS

IZOLACIJSKI MATERIJALI

INSULATION MATERIALS

gumene mje{avine
umre`ivi polietilen (XLPE)
bezhalogeni te{kogorivi poliolofini
PVC

rubber compounds
crosslinked polyethylene (XLPE)
halogenfree flameretardant polyolefine
PVC

Utemeljena 1927.

Founded in 1927

TUGONICA

ZAGREB

ZADAR

CENTAR

[UBI]EVA

KAKO NAS NAI?


HOW TO FIND US?

BRANIMIROVA ULICA

VUKOVARSKA AVENIJA

INDU
STRIJ
SKA
ZONA

ZAGREB istok

LJUBLJANA

SLAVONSKI BROD

ZAGREB zapad

eka
R ij

SAVA
INDUSTRIJSKA ZONA
AVA
r S
Rive

V
A
[

Y
O
U
R

H
R
V
A
T
S
K
I

C
R
O
A
T
I
A
N

P
A
R
T
N
E
R

P
A
R
T
N
E
R

Energija - komunikacije / Energy - Communication


Koledov~ina 1, P.O.Box 150, HR-10001 ZAGREB, CROATIA
Tel.: (++385-1) 24 82 600; Fax: (++385-1) 24 04 898
http://www.elka.hr
e-mail: elka-marketing@elka.hr

Anda mungkin juga menyukai