Tunnel convergence monitoring system (ACE-TCS)

Applications
Tunnel convergence monitoring system generally works
in....
Monitoring by two-dimensional displacement of the
tunnels or underground excavation work
Measuring the tilted wall of adjacent area in the
urbanizing construction work of underground excavation
Measuring displacement to check for the safety,
construction periods and decide excavation speed and
proportion

Features
Description
Model ACE-TCS Tunnel convergence monitoring system
conveniently measures any transformational scale, inclination or
proportion of tunnel or underground excavation work.
It consists of an inclinometer with X & Y at both ends of
tunnel, a displacement sensor, mounting bracket and an
extension tube as a kit.
Its gage is installed along with internal wall of tunnel by 1
2m (In case of single line, kit is 8~10ea. In case of double
line, kit is 14~16ea.) not to hinder transportation service.
With any transformational change inside a tunnel, the
displacement value makes angular inclinometer as much as
the value of X-axis. It also makes length displacement in
Y-axis to be output into electrical signals, calculated easily
and accurately with provided conversion factor. The first
absolute place is made by X, Y-axis, and the displacement
value can be conversed through present and first value.

High resolution by 0.01mm unit


High precision without errors caused by refraction
change on account of light emitting measuring system
Two-dimensional diagram of measured data
Minimized impact from construction work
Easy control & analysis of measured data
Semipermanent measurement by contrast with electronic
type
Automatic measurement
Rare impact from magnetic fields or noises

Ordering Information
Installing sites
Kind of tunnel
Circumference and point of tunnel

Ancillary Equipments
Universal terminal box (Model 7012/7024)

Our VW Tunnel convergence monitoring system semi


automatically operates after contacting signal cables of
inclinometer and displacement sensor to the terminal box.
Or you can control and automatically measure in long
distance with data logger or automatic data acquisition
system.
The measured data can be showed in 0.01mm unit in twodimensional graphic through our own analyzing program of
TCS-PRO.
The system has a built-in lightning protector and
temperature sensor to keep regular temperature. It has no
influence from magnetic fields or noises in underground
system to measure perfectly and semi-permanently.

[ACE-TCS in Seoul subway]

The products contained in this catalogue can be changed without any notification for improving the products.

www.aceinstrument.com / acens@naver.com

Tunnel convergence monitoring system (ACE-TCS)

Model

ACE-TCS

Part

VW Inclinometer

VW Displacement sensor

Sensor element

VW Type

Range

20 mm

Resolution

0.025% FSR (3 arc seconds)

0.025% FSR (0.005mm)

Accuracy

0.1 FSR

Nonlinearity

0.5 FSR

Coefficient of linear expansion

Less than 0.001% FSR /

Operating temperature

-40105

Built-in temperature device

Standard : Thermistor (3k)

Temperature device accuracy


Temperature device range

Less than 0.03 FSR /

Optional : RTD (2k)

Thermistor : -3080

RTD : -45100

Thermistor : 1

RTD : 0.7

Built-in lightning protection

Gas tube arrester (Frequency output lines)

Materials

Special stainless steel, Fluorinate series O ring, High grade silicone potting

Accessories

Mounting bracket (SPCC Plate, Zn Plating)


Anchor plate (AL Anodizing)
Extension rod (STS 304 series)
3/8" Set anchor bolt
Connection bolt

The Readout

Recommendation

This system is connected to the system such as the VW


readout units, data loggers to be data logging and data
acquisition system to monitor readings.

When setting the VW Tunnel convergence monitoring


system, the gage length about 1 point isnt exceeding
1.5m. If it exceeds 1.5m, the sensor error went on
accumulating and then the shake of profile is big
occurring, even if you put in high precision sensor.

Ace's Readout unit


ACE-800 (VW readout)
ACE-1000 (VW data recorder)
Ace's data acquisition system
ACE-1100 (VW mini logger)
ARF-100 (RF Data acquisition system)
We provide other companys data acquisition system
(CR-10, DT515 etc.) after consulting the kind, amount
of sensor, installing sites, operating manual or system.

Bracket

When installing the VW Tunnel convergence monitoring


system, you must revise the metal coefficient of linear
expansion according to the temperature change.
It is all right that you disregard the coefficient of sensor
itself. But the extension tube acts on large variable
because the extension tube is stainless.

Ball Joint Bearing

Extension Tube

Extension Connector

VW Convergencemeter

VW Tiltmeter

[Installation of ACE-TCS]

[ACE-TCS PROFILE]

The products contained in this catalogue can be changed without any notification for improving the products.