OmniCom - Release Notes

Copyright Omni Flow Computers, Inc. (c)2004 - 2011, All Rights Reserved.
*******************************************************************************
Version 1.49 - November 17, 2011
Configure
Edit Sites
- a search was added to facilitate finding a site or unit to edit
The user can enter search string which can be part of a site
name, unit name, IP address, TCP port, etc...
- provides access to standalone Convert Site program which
allows users to convert the Site file to a comma separated file
and/or Modbus Tester file and to import a comma separated file
into a Site file.
Communications
Connect Screen
- a search feature was added to facilitate finding a site or unit
to connect to. The user can enter search string which can be part
of a site name, unit name, IP address, TCP port, etc...
Receive/Transmit All Configuration
- Configuration can now be read/written without reading/writing
the report templates.
*******************************************************************************
Version 1.48 - August 29, 2011
Configure
Ports - Ethernet - Printing
- a configurable time out for printer reponse was added for each
network printer. It ranges from 5 to 300 seconds with a default
of 10 seconds.
Meter K-Factor and Viscosity Linearization
- if Viscosity Linearization is in use, only one K-Factor entry
will be available. A note is displayed on the K-Factor screen
to indicate when Viscosity Linearization is in use.
Meter Setup - App 20/24, 22/26
- the text of the Upstream Prover checkbox in the Prove group
was changed to 'Use Upstream Prover Volume .
General
Folder Preferences
- fixed a problem on Vista and higher operating systems - the
folder preferences were reverted back to the defaults after use
(e.g save a configuration file, import/export a file).
*******************************************************************************
Version 1.47 - November 12, 2010
Configure
Meter Setup - App 23/27
- Added display of the product name next to the product selection.
- Fixed an issue when online with firmware version 27.75.06, the
transducer density k3 thermodynamic factor was not being
displayed correctly.
Fluid Setup - App 27
- Corrected an issue where the product's base temperature value was
being put into the neo-Pentane component percentage whenever
the viscosity, isentropic exponent, HV override, or SG override
was changed.
- Fixed an issue where the AGA-10 selection for products 2-4 were
being stored incorrectly in the file.
Configuration Print - App 23/27 - Added print of the product name next
to the product selection.
General

File Open - App 27 - corrected an issue where the neo-Pentane component


percent was being cleared when a file was opened.
Sample Templates - App 22 - Batch Template for 22.74.30 and higher The registers 4149, 4249, 4349, and 4449 (previous day meter
factor used in net/mass calc) were changed to 4139, 4239, 4339, and
4439 (current Meter Factor used in net/mass calc).
*******************************************************************************
Version 1.46 - October 1, 2010
Configure
Factors and Constants - Transmitter fail low and high setpoints were
added for 20.75.02, 23.75.02, and 27.75.06 and higher.
Meter Type
- The meter types have been grouped according to type.
- 'Turbine/PD meter' label was changed to 'Pulse Type'.
- 'Coriolis Meter' label was changed to 'Coriolis Mass Pulse'.
- 'DP Head Device' label was changed to 'DP Device'.
- The ultrasonic meters are no longer available for selection if
there are no SV modules in the system.
Meter Setup - App 23/27
- a Low Flow Cutoff selection based on flow rate was added for
DP and pulse type devices for 23.75.02 and 27.75.06 and higher.
- for DP meters, the low flow cutoff value was moved to this screen
from the DP Setup screen.
- The transducer density selections are expanded to include
Transducer Density Not Used, Use Upstream Transducer Density,
Use Downstream Transducer Density (Isentropic Correction), and
Use Downstream Transducer Density (Isenthalpic Correction) for
DP devices that are not V-Cone, that have NG using an AGA-8 1994
or 1992 density method selected as the product assigned to the
meter and a valid density I/O (1-98) for 23.75.02 and 27.75.06
and higher. The Use Downstream Transducer Density was removed
for pulse types.
- The 'Disable NIST14 calculation of flowing density' item in the
Density group is only shown if 'NIST14' is selected as the product
for the meter run and a valid density I/O (1-98) is entered for
the meter. It is enabled if an upstream or downstream transducer
density is selected.
- the SV port number for ultrasonic meters is now not cleared when
any changes are applied in the Meter Setup screen.
Physical Meter Screen - for 23.75.02 and 27.75.06 and higher
- Flow calculations API 14.3(AGA-3):1992 and API 14.3(AGA-3):2010
selections were added available with orifice flange taps.
- The upstream temperature calculations are now shown when
'Temperature Probe is located Upstream' is not checked.
- The upstream temperature calculation was expanded to include
Isentropic Correction, Simplified Joule-Thomson Isenthalpic
Correction, Joule-Thomson Isenthalpic Correction, and
Joule-Thomson using AGA-10 for 27.75.06 and higher.
- The upstream temperature calculation has been added and includes
Isentropic Correction and Simplified Joule-Thomson Isenthalpic
Correction for 23.75.02 and higher.
- For V-Cone DP device types, only the Isentropic Correction is
enabled.
- The Cmp and dZ/dT are not used for Joule-Thomson - Isenthalpic
correction when the product assigned to the meter is NIST14
for 27.75.06 and higher.
Ultrasonic Meter
- the AGA-10 VOS entry is only enabled when the product assigned
to the meter is Natural Gas using AGA-8 1994 density method and
AGA-10 calculation.

- FMC meter types now have the Primary Measurement Source of


Serial and Pulse with Serial as the default selection for
23.75.02 and 27.75.06 and higher.
Viscosity Linearization - App 20/24 - the LCF used in Gross setting is
now saved properly for all meters.
Station Setup - A single meter run number with a trailing operator can
be entered to total one meter run (i.e. 1+ or 1-).
Fluid Setup - Apps 23/27 - for 23.75.02 and 27.75.06 and higher
- Viscosity Calculation selection was added
- Isentropic Exponent Calculation selection was added
- Relative Density(SG) base temperature selection was added for
27.75.06 and higher.
- HV use override or calculate selection was added.
- The new HV calculation methods, AGA-5(2009) and GPA 2172(2009),
were added.
- All of the ISO 6976 entries are removed and a single 'ISO 6976'
entry is shown for the HV calculation method for 27.75.06 and
higher.
- The HV calculation method of 'ISO 6976 15/15C' is replaced by
'ISO 6976 60/60F' for 23.75.02 and higher.
- HV override combustion/volumetric base temperature selection was
added for 27.75.06 and higher.
- Base Conditions combustion/volumetric base temperature selection
was added for 27.75.06 and higher.
- Reference Density calculation selection was added for Natural Gas
for all density methods except Redlich-Kwong.
- Relative Density(SG) entry is only enabled for Natural Gas when
the Reference Density Calculation is 'Relative Density(SG) x Dry
Air'.
- Base temperature is forced to 15.556C for Natural Gas using HV
method AGA-5(1999) and for all AGA-8 1985 density methods for
27.75.06 and higher.
- Base pressure is either 101.325 or 101.56 kPa (or configured
units) for NG and density methods AGA-8 1994 and 1992 gross
methods (2 and 3) and SGerg methods 1-4 for 27.75.06 and higher.
- The ISO reference density checkbox and reference temperature
selections are replaced by the reference density radio buttons
and base temperature combo selections for 27.75.06 and higher.
It is not available when the HV calculation method is
AGA-5(1999).
- Reference Density for products other than Natural Gas now only
support positive values.
AGA-8 1985 Analysis - an entry for N2% has been added.
Current Assignments - now does not show the DP low, mid, or high I/O
points when it is not a DP Device application (20/24, 22/26).
Configuration Transmit
- Register 3098 (totalizer rollover digits) is no longer
transmitted to the OMNI as it is a read-only register.
Configuration Files - On new file opens, the default shown will be the
latest revision for the application (20-27) and version
(EPROM = 74 and FLASH >= 75) selected. The user may select a
specific revision different from the default. When opening an
existing file which has the default revision, the file will be set
to the latest revision for that application and version.
Report Template Editor
The user may now edit the Report Templates online without having to
read all of the configuration first from the unit.
General
OmniCom now supports the Windows 7 Operating System (32-bit).
Windows 2000 no longer supported.

Application 25 is no longer supported and all references removed.


Help File
Factors and Constants Screen - added Transmitter Fail Setpoints. Each
application now has its own help page.
Prover Operate Screen - App 20/24 - Run Repeatability w/LCF updated.
Fluid Products Screen - App 23 and App 27 now have separate help
pages and include all the updates made in this release
Meter Setup Screen - updated the transducer density section.
Station Setup Screen - updated for station total and flows.
Physical Meter Screen - updated for flow calculations and upstream
temperature calculations.
Online Data Synchronization - updated for the editing of templates
online without configuration synchronization.
*******************************************************************************
Version 1.45 - September 29, 2009
Configure
Equipment Flags - fixed a bug with the Switch Bar Temperature flag
getting unchecked on Apply.
Meter Factors
App 20/24 - the meter factors are defaulted to 1.0 on new and
imported DOS files.
The Product Screen no longer allows zero for meter factor.
App 22/26 - the first meter factor in the meter curve is set to
1.0 on new and imported files.
The Product - Meter Curve Screen no longer allows zero for
the first meter factor on the curve and for any meter factors
that have a corresponding non-zero flow rate.
App 23/27 and 21/25 - The Meter Setup Screen no longer allows zeros
for meter factor.
Terminal Block Diagram - the fuse information is no longer provided
with the diagrams (users are now encouraged to use Volume 1 of the
Omni 3000/6000 manuals for the fuse information).
The 3000 and 6000 back panel diagrams are now individually
displayed according to the card cage selection.
General
The Technical Bulletin compendium is no longer supported. Each
individual bulletin is now installed in a "Technical Bulletin"
folder under the installation folder Manual subfolder.
*******************************************************************************
Version 1.44 - September 17, 2009
Configure
HART Input Configuration - added for 23.75.01 and up.
Meter Setup
DP meters - if stacked DP transmitters are not used, enter the
single I/O point in the high I/O instead of in the low I/O
point for 23.75.01 and up.
Stacked DP transmitters - the alarm limits and override are taken
from the first valid I/O point found in this order:
high, low, then mid for 23.75.01 and up.
Support for MV stacked DPs for was added 23.75.01 and up.
The MV I/O point is configured in the high I/O point.
Low and mid range I/O points are available as analog inputs
and cannot be shared over multiple meter runs.
Meter and Station Setup - a Mass or Net low/high flow rate alarm
units selection has been added for 23.75.01 and up.
Flowmeter - K-Factor Curve - the K-Factor Linearization Frequency (Hz)
changed from 16-bit integer to IEEE floating point Format for
23.75.01 and up. Modbus registers move from 3n22-3n33 to
19n01-19n12 where n is Meter Run number. The user may enter any
float number up to 7 significant digits.

GC Setup - An Actual or Dry GC Heating Value selection has been added


for 23.75.01 and up.
Ethernet Configuration - Host Port - when changing the Host ID and/or
Modicon settings, the communications are no longer lost so that
the Ethernet configuration can be synchronized with the SE Module.
General
The User Notes are no longer overwritten during installation. **Note:
This change will be effective on the NEXT installation as the
uninstall that is run on THIS installation goes with the existing
installation that is being replaced.**
Check For Updates now looks at the new web page for the version.
Help File
Check For Updates now has the new web site listed.
*******************************************************************************
Version 1.43 - August 28, 2009
Configure
HART Input Configuration - added for 22.75.02 and 26.75.01 and up.
Prover Density - Sarasota Constants - A problem was fixed where the
configured constants were being displayed as zeros.
Operate
Historical Reports - initial record retrieval
Alarms - the initial display was increased from 5 to 25 alarms.
Audit - the initial display was increased from 5 to 10 entries.
Help File
Product Measurement Algorithm 24C/54C/6C help was changed to simplify
the chart for the Alpha Coefficient.
*******************************************************************************
Version 1.42 - July 31, 2009
Configure
Modules - Added a check for allocated I/O that is affected by module
changes for 20.75.01, 24.75.01, and 27.75.03 and up. The user has
an opportunity to have those allocated I/Os automatically cleared.
HART Input Configuration - added for 20.75.01 and 24.75.01 and up.
Ports - Ethernet Configuration - added a check to prevent the
encapsulated Modbus and Modbus/TCP ports from being the same.
Station Density Temperature and Pressure now accept HART inputs for
20.75.01 and 24.75.01 and up.
Prover Inlet Temperature, Outlet Temperature, Switch Bar Temperature,
Inlet Pressure, Outlet Pressure, Plenum Pressure, Density
Temperature, and Density Pressure now accept HART inputs for
20.75.01 and 24.75.01 and up.
Operate
Retrieve Archives - A problem was fixed where there was a folder error
when the Archive Folder preference was set to a read-only folder.
*******************************************************************************
Version 1.41 - July 23, 2009
Configure
HART Network Setup screen - added for HM modules which includes
point-to-point, multivariable, and multidrop network types
selections for 27.75.04 and up.
HART Inputs - Signal Type indicates the network type it is on.
Process Inputs
An issue where there were "phantom controls" displayed on the
screen has been resolved.
Once an input has been assigned to Pulse Fidelity Error Counts the
tag entry is no longer available as there is no corresponding
entry/storage in the Omni for it.
Meter Setup
DP meters - if stacked DP transmitters are not used, enter the
single I/O point in the high I/O instead of in the low I/O

point for 27.75.04 and up.


Stacked DP transmitters - the alarm limits and override are taken
from the first valid I/O point found in this order:
high, low, then mid for 27.75.04 and up.
If there is a tag assigned to the I/O for the pulse fidelity error
counts on Apply, an error message is displayed and the tag is
automatically cleared.
Physical Meter Setup - App 23 - no longer shows ISO5167 or Version 2003
as they are only applicable to App 27 (was incorrect in v1.40).
Fluid Products - The Base Temperature and Base Pressure entries will
only be available for Natural Gas and NIST14 for 27.75.19 and up.
Configuration Print
The Base Temperature and Base Pressure will only be printed for
Natural Gas and NIST14 for 27.75.19 and up.
The 'Ethernet Allocations' section was changed to be the 'Port
Allocation' section and now shows all S and SE Module ports and
their type, Serial or Ethernet, instead of just showing the port
s
for the SE Modules.
I/O points used for pulse fidelity error counts no longer have a
tag printed.
Diagnostics
HART Input Summary screen added for 27.75.04 and up.
*******************************************************************************
Version 1.40 - April 30, 2009
Configure
Modules - Added support for the HT (point-to-point) and HM (multidrop)
HART modules for 27.75.03 and up. Additionally, the user may
specify the actual module installed (A-2, B-4, S-1, SE-2...).
Configuration Tree - now shows actual modules installed (A-2, B-4...)
for 27.75.03 and up.
HART Inputs - a screen to configure the HART inputs (25 - 88) for
modules for 27.75.03 and up. Supports DP, temperature, pressure,
and auxiliary input types.
Meter Run Setup, Meter Temperature, Meter Pressure, Density
Temperature, Density Pressure, and Auxiliary Inputs all accept
HART inputs for 27.75.03 and up.
Meter Run Setup - for applications 20/24 and 22/26
The text "Use Meter Factor in Net" was be changed to "Use Meter
Factor in Net and Mass Calculations".
Meter Configuration for 27.75.03 and up - V-Cone
Text is "DP Head Device" instead of "Orifice" for selection (0)
V-Cone meter types (5) should now be configured as a DP Head
Device(0).
Physical Meter Setup for 27.75.03 and up - "Orifice Plate Taps" is now
"DP Head Device Type" and includes a selection for "V-Cone" (9).
Configuration Print - fixed a problem where the flow stable units
were printed as "hours" instead of "minutes".
DOS file imports - fixed a problem where the energy units were not
being set properly when importing a 27.71 file.
Diagnostics
I/O Overview - now shows actual modules installed (A-2, B-4...) for
27.75.03 and up.
Help Files
Updated for HART Inputs.
Updated for the V-Cone meter type changes.
*******************************************************************************
Version 1.39 - February 18, 2009
Configure
Meter Setup - support for MV stacked DPs for 27.75.02 was added.

The MV I/O point is configured in the high I/O point.


Low and mid range I/O points are available as analog inputs and
cannot be shared over multiple meter runs.
Alarm limits and override information come from the MV high point.
Process Inputs - the alarm limits and override information can only
be configured on the high point for MV Stacked DPs.
*******************************************************************************
Version 1.38 - January 30, 2009
Configure
General Setup - date format changes are now not allowed when the
Archive is running.
Ethernet Ports
Ethernet Printing - the print queue name can now be configured
for the network printers for Omni SE v1.56 and up.
Advanced - an entry has been added to configure the amount of time
in seconds the host waits before closing the socket connection
after the client device has powered down during active
communication for Omni SE v1.56 and up.
Meter and Station Setup - a Mass or Net low/high flow rate alarm units
selection has been added for 27.75.01 and up.
Station Definition - the definition was incorrectly being overwritten
during the connect sequence to a 68-6001 CPU board. This problem
occurred when the Omni unit's configuration did not match the
transmit configuration file's station definition. The file's
definition was overwritten before the file was transmitted. This
issue was introduced in OmniCom v1.34.
Terminal Block Diagram
Is now only available with command line switch "-TB". A note has
been added to the top of the screen regarding user
responsibility.
A problem of missing modules with configurations of more than
8 modules has been corrected.
Temperature and Pressure I/O for HV and SV meters - the temperature
and pressure are auto-assigned for these meter types so the I/O
entries are now disabled.
Product Setup - GPA TP 16 - an option was added for ASTM D1250 1952
edition table selection for 22.74.33 and 22.75.01.
Fluid Products
Water (K&K) now allows the user to select the Viscosity Calculate
option.
The GC entry is now only enabled if the GC equipment flag is
checked.
GC Setup - An Actual or Dry GC Heating Value selection has been added
for 27.75.01 and up.
File Save - App 24, 25 and 26 - the reference temperature for Products
1-8 were being overwritten.
Import DOS Configuration Files
Users are now able to select the firmware version and revision on
file save after a DOS file import.
Improvements have been made to clear values for new database
items added for firmware versions 74 and 75.
The serial port configurations are checked on import and any
"RTU Modem" protocol settings are changed to "RTU".
Receive All/Transmit All Configuration - App 27 - Fluid Prod 1-4 NIST14
basis selections had been mistakenly omitted.
Operate
Prove Control - App 22/26 - the Manual Implement Meter Factor Timer is
now available for display for 22.74.33 and 26.74.32.
Batch Stack Edit - the out of range error for the density/gravity
adjustment was changed to display the exclusive instead of the

inclusive range.
Diagnostics
Modbus Tester - the Custom Packets were not being configured correctly
when using the Register List.
General
Flowmeter Description - Apps 20/24 - the new file dialog and the
configuration tree now include the "Coriolis" meter.
Mass and Mass Flowrate units - Metric applications now show "Tonnes"
instead of "Tons" and "Tonnes/hr" instead of "Tons/hr".
New Sample templates were added for application 27 with 'Tons'
replaced by 'Tonnes'.
Help File
Analog Outputs - the correct help text for this topic was inserted.
Physical Meter Setup - a restructure and clarification was provided
for the ISO 5167 help.
Meter Density - the Solartron gas constant 'K5' was renamed to 'Cal
Gas Constant'.
Operate Batch Control - the word "increased" replaced the word
"incremented" and "decreased" replaced "decremented".
*******************************************************************************
Version 1.37 - October 13, 2008
Configure
General Setup - Equipment Flags - 2nd GC flag
The 2nd GC flag was sometimes being auto-set on screen entry for
pre-GC2 files (files under versions 23.74.10 and 27.74.11).
Omni I/O - Current Assignments - Terminal Block Diagram
A Card Cage option was added to select between a 3000 or 6000 card
cage which may be different from the Omni Type designation.
This option is stored with the file but is not stored in the
Omni's database.
Station Setup - Flow Low and High Limits
For applications 23/27 the screen displayed volume units instead
of mass units.
For applications 20/24 - the screen was changed to display mass
units if mass pulses are selected on the first meter in the
station definition.
GC Setup - Danalyzer Type - the label was changed from "UK" to "ISO".
Import DOS Configuration Files
The DOS file import has been extended to support the latest
releases of OmniCom for DOS versions 71, 72, and 73 for all
firmware applications v71 and up.
Several corrections had to be made to the DOS files in order for
them to be imported into the correct registers and in the
proper format for use with firmware versions 74 and up.
Operate
Retrieve Text Archive - Start Date
The retrieve start date format was always shown as MM/DD/YY even
if the data format was configured for DD/MM/YY.
General
New Sample templates were added for 22.74.30 and 26.74.30.
Help File
Prover - Auto Proving - a correction was made to the paragraph
concerning meter factor implementation.
Process I/O and Live Inputs for SG input types - more information was
provided regarding analog verses digital pulse (frequency) types.
GC Setup - help was added for Danalyzer Type
*******************************************************************************
Version 1.36 - August 28, 2008
Configure
Fluid Products Setup

The option to "Use Override" or "Calculate" was added for the


Viscosity and Isentropic Exponent fields for 23.75.00 and up.
Note that negative values are no longer allowed for the
overrides for 27.75.00 and up.
File Import DOS Config
When saving an imported DOS file, the user now has the option to
save the file for a 68-6001 CPU (v74) or 68-6201 CPU (v75 and
up).
Help File
Meter Setup - Prover - added clarification of the upstream and
downstream volumes for unidirectional compact provers.
*******************************************************************************
Version 1.35 - August 21, 2008
Configure
Meter Setup
App 21/25, 23/27 - HV and SV meter types - the DP I/O point is only
added to the selection list if there are valid I/O points
remaining for the auto-assignment of the temperature and
pressure I/O points.
App 21/25, 23/27 - SV meter types - if the DP I/O point is cleared,
clear the SV Port and SV Modbus ID for the meter.
App 23/27 - Disable NIST14 density calculation - the product
selected for the meter must be a NIST14 fluid type before the
"Disable NIST14 density calculation" selection is enabled.
Fluid Products - Setup
Density Method - there is a new NX-19 modified method added as
method 20 and labeled "NX-19 MOD - N2/CO2/SG" for 27.75.00 and
up. The current method 18 is now labeled
"NX-19 1962 - N2/CO2/SG".
Calculate Viscosity and Isentropic Exponent has been added when the
NX-19 MOD density method is selected for 27.75.00 and up. If
user selects to calculate viscosity, a reference viscosity is
requested in Pa.s.
Base Pressure - the base pressure units are now marked as absolute.
Neo-pentane selection - if the HV method was changed, the
neo-pentane selection would be displayed even if the density
method was not an AGA-8 detailed method.
Densitometer I/O
If the density I/O point is changed to an existing pulse type
density I/O that is assigned to a meter, station or prover and
Apply is pressed, the densitometer constants are copied from
the existing assignment to the particular meter, station or
prover densitometer that is being changed.
Densitometer Constants Setup (Solartron/Sarasota/UGC)
If the user changes the densitometer constants and presses
Apply, the densitometer constants are updated for the meters,
station, and prover that share that density I/O point.
Default Configuration File
Apps 20/24, 22/26, and 23/27 - Modules A-1, B-1, E-1, D-1, S-1, SE-2
(Ethernet on Port 4 with v1.50 and up checked).
Apps 21/25 stay the same as now with A-1, A-2, A-3, S-1 and S-2.
All apps - MR1, MR1 Temperature, MR1 Pressure equipment flags
checked
Apps 20/24, 22/26 - MR1 Density and MR1 Density Temperature
equipment flags checked
Apps 20/24, 22/26 - Prover, Prover Outlet Temperature and Prover
Outlet Pressure equipment flags checked.
Report Template Editor
Importing a template - pressing the Cancel button after a template
import did not restore the original template.

General
The method of determining an existing instance of OmniCom has been
changed to a faster method to prevent multiple simultaneous
instances.
Help File
Peer-to-Peer - Transactions - Points - added information regarding
ASCII registers read/write using the Modicon protocol.
Equipment Page - added hyperlinks to corresponding help for each flag.
*******************************************************************************
Version 1.34 - July 30, 2008
Configure
General Setup - Decimal Resolution - Apps 20/24 - the Meter Factors in
the file were not auto-adjusted if the Meter Factor decimal places
for the Batch Report were changed.
Process Inputs - the override codes for N2 (3881), HV (3882), and CO2
(3883) were all being written to the override code register for SG
(3880).
Virtual Inputs - virtual PID types should not have been allowed.
Meter Setup
The Meter ID, Model, Size and S/N entries were not limited to 8
alphanumerics so the user could enter more characters and find
them truncated to 8 when Apply was pressed.
App 21/25, 23/27 - HV and SV meter types should not have allowed
Remote 99 or Virtual (98-90) inputs for I/O points for the
Honeywell HV and Rosemount SV meter types. For Honeywell HV
types, the meter's temperature and pressure I/O selections
are now grayed out as they are auto-selected by the Omni.
Flowmeter - K-Factor Curve - the K-Factor Linearization Frequency (Hz)
changed from 16-bit integer to IEEE floating point Format for
27.75.00 and up. Modbus registers move from 3n22-3n33 to
19n01-19n12 where n is Meter Run number. The user may enter any
float number up to 7 significant digits.
Density screens fop Meter Run, Station, and Prover - if the density
type does not match the density I/O point type, a message is
displayed and the density type is auto-cleared to
"No Type Selected".
Fluid Products Setup
The option to "Use Override" or "Calculate" was added for the
Viscosity and Isentropic Exponent fields for 27.75.00 and up.
Note that negative values are no longer allowed for the
overrides for 27.75.00 and up.
Neo-Pentane option for HV Method
1) The HV method options for the neo-pentane should display for
any of the HV methods including AGA-5.
2) The HV Method options for neo-pentane should display if the
user selects Natural Gas only with an AGA-8 detailed density
method.
App 27 - HV method - ISO 6976 Base Temperature selection change
auto-corrected the Base Temperature to the new selection but
did not write the value to the Omni when the user pressed
Apply.
The density method group and corresponding radio buttons sometimes
displayed on the wrong page if multiple documents were opened.
Live Inputs - the full scale value was being displayed for the zero
scale value for SG, HV, N2, and CO2.
User Displays - Key Sequence - re-allowed one character key sequences.
(See release notes for v1.33)
Configuration Print
App 23/27 - The value for the AGA-10 Enable flag for Product 1 was
used to print for all four products instead of printing each

individual product's AGA-10 enable flag.


File Import of DOS configuration was not importing Serial Port 6
configuration and the Enable Meter Alarm inactive flags properly.
Operate
Prove Control
Manual Implement Button
App 20/24, 22/26 - the button was being enabled during a prove
if the user unchecked the Auto-implement Meter Factor checkbox.
App 23/27 - the button has been disabled as it does not apply.
Help File
Fluid Setup - Viscosity and Isentropic Exponent - the new calculate
selection has been added.
GC Setup and Ports - added a disclaimer about support of Applied
Automation's Gas Chromatograph.
FMC MPU 1200 - Alarm Limits - showed "Maximum Burst Percent" but should
have been "Minimum Burst Percent".
Instromet Ultrasonic Meter - Alarm Limits - Max Flow Deviation - added
the primary and secondary source information.
Ethernet Configuration - added some information on how to enter IP
address type fields.
Gas Chromatograph - added a reminder note about selecting the GC
protocol on Serial Port 3.
*******************************************************************************
Version 1.33 - June 12, 2008
Configure
Prover Characteristics - App 24/26 - the high range for the thermal
expansion was 0.00004 but should have been 0.00006.
User Displays - the Key Sequence field must be at least 2 characters
to prevent confusion with the major data displays and must not
contain any numerics.
Omni I/O - Current Assignments - An I/O Summary has been added which
displays the I/O number, tag, and description for the meters,
station, and prover.
Operate
Prove Control
App 20/24 - a message is displayed for the user when a Manual
Implement of the meter factor is performed.
If viewing a meter run and the Omni began a prove sequence for a
different meter run, the meter run number and transducer data
corresponded to the original meter run being viewed instead of
the proving meter.
Help File
User Displays - Key Sequence - updated regarding more than one
character entry.
Report Setup and Report Template Editor - added a note about the new
templates for 74.30.
Gas Chromatograph - Components - updated regarding entering the SG and
BTU.
Peer To Peer - Transaction Group - added a note about a zero point
count terminating the list.
Ports - added some specific information for ports 1-4.
Ports - Protocol - added a note regarding CRC should be on.
Operate Screens - noted which ones are only available ONLINE.
*******************************************************************************
Version 1.32 - May 15, 2008
Configure
General Setup - Setup - Location and Company Name have been adjusted
to 38 characters instead of 40.
Ports - Hardware - Serial Port 4 - Modbus ID vs Node ID label did not
match the protocol selection.

Product - Measurement Algorithm - Add API 11.1 MPMS (1980 edition)


Tables 5A/6A, 5B/6B, and 6C for 22.75.00 and up.
A Hydrometer Correction option was added for Tables 5A/5B for
22.75.00 and up.
Batch Setup - A Net Weight Calculation Method selection was added for
22.75.00 and up. The user may select the preferred method to
convert NSV to net weight.
Receive All/Transmit All Configuration - App 22 - The Prover
Volume Base Temperature and the Operational Setup Allowable Flow
Rate Change during sample time fields were not being read/written.
New Files - a CPU selection has been added. If 68-6201 is selected,
the firmware version is 75. If 68-6001 is selected, the firmware
version is defaulted to 74. If the CPU is a 68-6201, the CPU
Serial Number is displayed on the title bar.
Operate
Archive Maintenance - Apps 22/26 - hide the Archive Memory Status and
the Number of Files Allocated fields as they do not apply.
Batch Control
Labels were added to the headings.
App 22.74.06 and up - Net and NSV totals were using gross decimal
places instead of net decimal places. The Batch Remaining now
now uses the configured batch preset volume type (net or gross)
decimal places to format the value.
Batch Stack Edit
English applications - if you edited an existing batch stack
gravity adjustment and the adjustment method was API, the label
and units showed SG instead.
If you edited an existing adjustment and selected none for method,
the adjustment value cleared on the edit screen but did not
clear out on the batch schedule list.
Prove Control - App 22/26 - the Manual Implement Timer is now being
read and displayed after a prove is complete and shows the amount
of time the user has to manually implement the new meter factor.
Help File
Product Measurement Algorithms - Mass Calculation - the help was
re-written for this entry.
Prover Characteristics - the help was enhanced for the Thermal
Expansion and Linear Coefficient.
Prove - Auto Prove Setup - the help for "Auto prove at startup after
meter has been down more than" had the help for "Minimum amount
of flow".
Report Setup - Added some clarification and examples for the
"Checked/Proved For" string.
*******************************************************************************
Version 1.31 - April 10, 2008
Configure
General Setup - Setup - a "Status Screen Default?" check box has been
added for 23.74.30 and up.
Omni I/O
Virtual Inputs 98-90 are now available for 23.74.30 and up.
Process Inputs and Temperature I/O screens - the damping code
selections for temperature input types were incorrect for H and
HV modules.
Remote Input 99 - all limits, input scaling, overrides, and damping
codes are set to N/A to match the Omni.
Current Assignments - Terminal Block Diagram
The tag name is used for the terminal descriptions if one is
provided otherwise the description (ie. Meter 1 Temperature) or input number is used.
The Digital I/O type is shown if known as (Input) or (Output).

The Process Input signal type is shown after the tag or


description.
The A/O type has been added.
Ports
Ethernet - configuration of the Omni SE module has been added
for 23.74.30 with Ethernet firmware v1.50 and up.
Meter Setup
Expanded the upper limit of range of Max Counts field from 9999 to
9,999,999 for 23.74.30 and up.
Added a "Max Good Pulses" field to the Pulse Fidelity group for
23.74.30. The range is from 0 to 999,999,999 with a default of
zero.
FMC MPU 1200 Setup - A series selection was added where the user may
select Series A or Series B for 23.74.30. The default is Series A.
FLOWSIC Setup - Temperature and Pressure read/write options were added
for 23.74.30.
Fluid Product Setup
The GC Stream selection moved from the Meter Run Setup screen to
the Fluid Product Setup screen for 23.74.30.
Added a "Soave-Redlich-Kwong Equation of State" checkbox when the
user selects the Redlich-Kwong density method. If the users
checks the SRK box, they are prompted for the "Accentric
Factor" (the default value is zero).
HV Method - neo-Pentane addition for the ISO 6976-95 method - the
first option was changed to read: "Use neo-pentane component"
instead of "Disregard neo-pentane component".
Batch Setup - Add Option to Start Batch with Current Date/Time even if
Meter not Active for 23.74.30 and up.
Peer To Peer - to prevent contention when two Omnis are trying to be
the master when active redundancy mode is selected, the user can
now select which Omni is to be the master for 23.74.30 and up.
Report Template Editor
Sample Templates - there are new Batch and Daily Report Templates in
the sample templates folder for 23.74.30 and up.
Report View - no longer allows template imports when on the Report
View as it is not editable.
Operate
Prove Control
Corilolis Meters - display "Mass" and "kg" for the first column
heading. Level B access to meter type is enabled in 23.74.30.
The meter factor returned from the Omni was not compensating for
the Prove Report MF Decimal Resolution configuration. This
value is now auto-adjusted in OmniCom for firmware versions
before 23.74.30.
Communications - ASCII protocol would fail when reading or writing the
Ethernet configuration or Report Templates.
General - Help Menu - a "Check For Updates" utility has been added to allow
the user to see if there are updates available for OmniCom.
Help File
Help for the "Check For Updates" utility has been added and includes
a link to the Omni software updates web page.
*******************************************************************************
Version 1.30 - March 12, 2008
Configure
Omni I/O
Virtual Inputs - the override code was being set to "Always Use"
but now it is not used and displayed as N/A to match the Omni.
Current Assignments - Terminal Block Diagram
Added the display of the back panel or extended back panel
bitmap, AC Power selection, and a Save and Print button.

Some of the terminal descriptions were updated.


Batch Setup - Add Option to Start Batch with Current Date/Time even if
Meter not Active for 24.74.30 and up.
Meter Setup
Expanded the upper limit of range of Max Counts field from 9999 to
9,999,999 for 24.74.30 and up.
Added a "Max Good Pulses" field to the Pulse Fidelity group for
24.74.30. The range is from 0 to 999,999,999 with a default of
zero.
Prove
Switch Bar Temperature - has been added as a transducer input for
unidirectional pipe compact pulse interpolation type provers
for 24.74.30 and up.
Peer To Peer - to prevent contention when two Omnis are trying to be
the master when active redundancy mode is selected, the user can
now select which Omni is to be the master for 24.74.30 and up.
Configuration Print - compressed printing for unassigned or unused
items.
Report Template Editor
Sample Templates - there is a new Daily Report Template in the sample
templates folder for 24.74.30 and up.
Operate
Batch Control
The batch totalizers and batch size were changed to allow negative
numbers.
Batch Stack
The batch size was changed to allow negative numbers.
A Reference Density Adjustment Method and Adjustment Value columns
were added for 24.74.30. The user enters a reference density
based on the method selection. The methods are:
0 = No Reference Density Adjustment Required (default)
1 = Adjust Reference Density at Batch Stack Shift
General
After a connection to a unit whose software application was not set to
20-27, the user saw the message, "The application you are using
is not yet supported". The message would continue to appear each
time the user started OmniCom or tried to open a new file until a
new or existing file was opened or a connection was made with a
valid application. Now the user will see the message, "The
application, XX, is not a valid application" where XX is the
application read in from the Omni after a connection. The user
will no longer see it on OmniCom start or new file opens.
Help File
General Setup - Setup - Computer ID correction - the number of allowed
characters was 16 and was changed to 8.
Omni I/O - Process I/O - Analog Outputs - Remarks field - the number of
allowed characters was 32 and was changed to 16.
Ports - Serial - Hardware - help for the Modbus ID was added.
Meter Run/Prover/Station/Density Temperature and Pressure and Density
Setup - Alarm Limits - High Alarm - read "the low alarm activates"
and was changed to "the high alarm activates".
*******************************************************************************
Version 1.29 - February 14, 2008
Configure
Omni I/O - Current Assignments - a Terminal Diagram screen was added
to show a suggested terminal block diagram based on the
configuration.
FLOWSIC Setup - Temperature and Pressure read/write options were added
for 27.74.30.
Fluid Product Setup - the GC Stream selection moved from the Meter Run

Setup screen to the Fluid Product Setup screen for 27.74.30.


Batch Setup - Add Option to Start Batch with Current Date/Time even if
Meter not Active for 27.74.30 and up.
Report Template Editor
Sample Templates - there is a new Batch Report and Daily Report
Template in the sample templates folder for 27.74.30 and up.
*******************************************************************************
Version 1.28 - February 1, 2008
Configure
General Setup
Setup
A "Status Screen Default" check box has been added for
20.74.30 and 22.74.30 and up.
Daylight Savings - the daylight savings dates are now defaulted
to 00/00/00 instead of 01/01/02 for new files. OmniCom
displays the current value on the screen, however, if the
date read in from the Omni is invalid or 01/01/02, the
Apply button is enabled and when pressed a date of
00/00/00 is sent to the Omni. Select 01/01/02 on the
date picker and press Apply to disable daylight savings
in the Omni.
Equipment List - Prover - a Switch Bar Temperature I/O checkbox
has been added for 20.74.30, 22.74.30, and 26.74.30 and up.
Factors and Systems Constants - if any of the units are changed,
a message is displayed that the change may affect other
entries in the system.
Decimal Resolution - Batch and Prove Report Meter Factor decimal
places are now configurable for 22.74.30 and 26.74.30 and up.
Omni I/O
Virtual Inputs 98-90 are now available for 20.74.30 and 22.74.30
and up.
Ports
Ethernet - configuration of the Omni SE module has been added
for 20.74.30 and 22.74.30 with Ethernet firmware v1.50 and up.
Hardware Setup - Baud Rate of 57600 was removed.
Meter Setup
Pulse Fidelity checking was added for Instromet UFMs for 23.74.20.
Expanded the upper range limit of the Active Frequency field from
999 to 65535.
Expanded the upper range limit of the Error Counts field from 999
to 65535.
Expanded the upper limit of range of Max Counts field from 9999 to
9,999,999 for 20.74.30, 22.74.30 and 26.74.10.
Added a "Max Good Pulses" field to the Pulse Fidelity group for
20.74.30, 22.74.30 and 26.74.10. The range is from 0 to
999,999,999 with a default of zero.
The pulse fidelity max good pulses field upper limit was extended
from 999,999 to 999,999,999 for 27.74.21 and up.
Physical Meter - Orifice/VCone - Provide user with a pop-up warning
on Apply if orifice/cone inside/measured diameter is greater than
pipe size.
Prove
Operational Setup - a "Print Prove Passes" checkbox was added
for pulse interpolation provers for applications 20/24 and
22/26.
Switch Bar Temperature - has been added as a transducer input for
unidirectional pipe compact pulse interpolation type provers
for 20.74.30, 22.74.30, and 26.74.30 and up.
Product Screen - the density correction factors are now available to be
assigned for meter runs 1-4 and station for each product for

20.74.30 and 22.74.30 and up.


Product Setup
A Base Pressure (Pe) setting was added for the API 11.1 (2004)
Commodity Types tables. It also applies to any of the API 11.1
(1980) tables whenever the user has selected "Use API 11.1(2004)
F factor for CPL". Applies to 22.74.30 and up.
Entry of a negative SG for the API 11.1 (2004) Commodity Types is
no longer allowed.
The Vapor Pressure units were shown as the configured units however
for firmware versions below 24.74.19, the vapor pressure units
are hard coded as kpa(abs).
Tables A, B, C, and D for liquid applications gave an Exception
Code 02 when online for firmware versions below 20.74.22,
22.74.06, 24.74.18, and 26.74.10.
Fluid Products Setup
An option was enabled to add the neo-Pentane component to the isoPentane component or disregard it for 23.74.20.
Instromet - added option for Primary Measurement Source for 23.74.20.
The options are Serial and Pulse. The default is Serial.
Batch Setup - Add Option to Start Batch with Current Date/Time even if
Meter not Active for 20.74.30, 22.74.30 and 26.74.30 and up.
Peer To Peer - to prevent contention when two Omnis are trying to be
the master when active redundancy mode is selected, the user can
now select which Omni is to be the master for 20.74.30,
22.74.30, 26.74.30, and 27.74.24.
Report Setup
Allow a Daily Report Time of 24:00 for 23.74.20 and up - allow the
daily and auto-batch end contract time to be set to 24:00 so
that the date on the reports show the date the batch ended. A
time of 24:00 shows it ended at the end of the date shown on
the report.
Configuration Print
If there were no Boolean Statements configured, the Variable
statements did not print.
Density/Gravity I/O units were either missing or incorrect.
Edit Serial Passwords did not work correctly when the port was set for
Modicon compatible protocol.
Import DOS Configuration Files - the Omni 3000/6000 Type designation
was not being interpreted correctly when the file was read in.
File Import/Export of configuration sections that are common to all the
applications is now allowed for advanced users. The following items
are available: Ethernet Configuration, User Displays,
Boolean/Variable Statemtents (cannot import while online),
Custom Modbus Packets, Archive Configuration, and Allen-Bradley
Packets. Please see the help file for each configuration item
for more information on how to employ this feature.
Transmit All Configuration/File Save
Daylight Savings - the daylight savings dates are now defaulted
to 00/00/00 instead of 01/01/02 for new files. When
transmitting the configuration to the Omni/file save, any
invalid or 01/01/02 daylight savings dates are automatically
converted to 00/00/00 before transfer/save.
Report Template Editor
Sample Templates - there is a new Daily Report Template in the sample
templates folder for firmware versions 20.74.30, 22.74.30 and
26.74.30 and up.
Operate
Reports
There is a new Preference screen under the Edit Menu which allows
you to set up your folder preference for where your reports are

stored and the file name preference (instead of requiring a


selection on each report save).
Report Printing - automatically asks if you would like to print
the report condensed if the report width exceeds the maximum
for the printer orientation setting.
Alarm Report - the number of alarm events has been increased from
150 to 500 for 22.74.30 and up.
Archives - there is a new Preference screen under the Edit Menu which
allows you to set up your folder preference for where your archive
data is stored which replaces selecting the folder via the "Archive
Path" item on the Operate tree.
Raw Archive
When reading the Raw Archive records (701-710), float values were
not being translated correctly when the port was set for
Modicon compatible.
Speed up of Raw Archive Retrieval - correct the check of the
firmware version when reading archives 701-712 for 22.74.06 and
26.74.10 and up.
Text Archive
The file extension was changed from ".arc" to ".arc.txt" to prevent
the file being opened with a popular zip file program.
The Text Archive retrieval process was improved. OmniCom would
sometimes time out and return "No records found" if the Omni
was very busy.
Batch Control - Batch Status - showing "In Progress" when actually
"Suspended" if the batch was suspended while in progress.
Batch Stack
A Gravity Adjustment Method and an Adjustment Value was added for
20.74.30 and 22.74.30. The user enters either an SG or API
based on the method selection. The methods are:
0 = No Gravity Adjustment Required (default)
1 = Adjust SG Gravity at Batch Stack Shift
2 = Adjust API at Batch Stack Shift
A Reference Density Adjustment Method and Adjustment Value columns
were added for 26.74.30. The user enters a reference density
based on the method selection. The methods are:
0 = No Reference Density Adjustment Required (default)
1 = Adjust Reference Density at Batch Stack Shift
Diagnostics
Modbus Tester
Custom Packets Data Type added - selectable for function codes 03,
06(Modicon only), and 16(Modicon only). The user then selects
a Modbus Address of "001", "201", or "401". If the Omni's
configuration has been read, the data can be formatted and
displayed according to the configuration for the packet.
Register List added - added the ability to transmit and maintain a
list of registers.
The connection type is verified against the transmission type
before sending. If they do not match, an message is displayed.
The data values displayed from the last good read were not being
cleared when there was an error on the next read.
Communications
Status Bar - added the Protocol type and Modicon compatible flag when
online.
View Menu
Comms Log - large logs take too long to view and clear
The comms log are now saved to disk every 20,000 logs. The user
can access and display each of the historical files using the Vi
ew
Menu Comms Log screen. A file of 20,000 logs takes about 13

seconds to display. The clearing of the current log in progress


is
now only a few seconds. The current log in progress can also be
saved to a file at any time.
Comms Statistics - added a feature to view some statistics on the
communications. See the Communications tab under Preferences
in the Edit menu to clear the stats on each new connection.
RS-485 connections - improved the speed of communications for firmware
versions 20.74.25, 22.74.30, and 26.74.30.
Modicon compatible protocol - the register count was incorrect when
writing ASCII strings.
A command line switch was added to enable a keep-alive poll for TCP-IP
connections. The switch is "-idleXXX" where XXX is the number of
seconds of idle time before a poll to a register common to all
applications is issued to maintain the connection. Use this
feature at your own risk because it could bypass the inactivity
time out configured in the Ethernet module.
General
New Files - the user is now allowed to select a revision for the
application specified. After selecting the application, press the
select button to see all the firmware versions OmniCom
supports. Only the features allowed for that revision are
enabled/shown on the screens. A revision of "--"
(i.e. 20.74.--) indicates all the fields supported by OmniCom
for that application are enabled/shown (currently the default).
There is a new Preferences screen under the Edit Menu. This screen
contains import/export folder and other preferences.
The Help menu About box now shows the PC ID that is used when
transmitting a configuration to the Omni.
The installation now supports the Windows 2003 Server Operating System.
Use the preferences to prevent file sharing issues.
The installation now supports the Vista operating system.
Help File
General Setup - daylight savings - notes were added on how to disable
daylight savings in the Omni.
Meter Setup - the help is now specific for the application.
Meter K-Factor Curve - App 27 - Nmi K-Factor - Added help for the
Accountable Alarm.
Product Tables - GPA TP27 and GPA TP15 extended have now been made
official by API and given Chapter 11.2.4 and 11.2.5 designations
respectively.
Boolean Statements - User Defined Alarm Messages - corrected the
register range for the different applications.
Variable Statements - added a clarification of the totalizing
examples.
Custom Data Packets - More examples for all the different data types
were added.
Raw Archive Retrival - added notes regarding the registers used,
Modicon, and the data formats.
Added a section on Exception Codes from the Omni in Trouble Shooting.
*******************************************************************************
Version 1.27 - June 21, 2007
Configure
General Setup
Setup - a "Status Screen Default?" check box has been added for
26.74.10 and up.
Factors and Systems Constants
Configurable pressure units were added for 26.74.10 and
include kPa, bar, and kg/cm2.
An Energy Units selection has been added for 27.74.21. The

selections are Gj and kWh.


Equipment Flags - equipment flag registers are now available in the
firmware for 26.74.10 and up.
Omni I/O
Digital I/O - Control Outputs - expand the assignment entry to
include values up to 18999 (was only allowing up to 17999).
Virtual Inputs 98-90 are now available for 26.74.10 and 27.74.21.
Ports - Ethernet - configuration of the Omni SE module has been added
for 26.74.10 and 27.74.21 with Ethernet firmware v1.50 and up.
Physical Meter Run - Orifice meters - Added a "Use Simplified
Joule-Thomson equation" checkbox when ISO5167 version selected is
Version 2003 (E) for 27.74.21 and up.
Fluid Products - Setup - Added a "Soave-Redlich-Kwong Equation of
State" checkbox when the user selects the Redlich-Kwong density
method. If the users checks the SRK box, they are prompted for the
"Accentric Factor" (the default value is zero).
Product Screen - the density correction factors are now available to be
assigned for meter runs 1-4 and station for each product for
26.74.10 and up.
Product Measurement Tables
GPA 27 23/24E tables were added for 26.74.10 and up.
API MPMS 11.1 (2004) tables were added for 26.74.10 and up.
Product Setup
An "API 11.1(2004) F factor for CPL" selection was added for the
API MPMS 11.1 (1980 edition) tables for 26.74.10 and up.
An "Use Separate CTL and CPL" selection was added for the API 11.1
(2004) Commodity Types tables for 26.74.10 and up.
The F-Factor entry is now grayed when the user selects the
Measurement Algorithm for API 11.1 (2004) Special Applications
as it is not used for application 26.
The F-Factor entry is now disabled when the user selects the
Measurement Algorithm for Table 24C and also selects "API 11.1
(2004) F factor for CPL" for application 26.
A Base Pressure (Pe) setting was added for the API 11.1 (2004)
Commodity Types tables. It also applies to any of the API 11.1
(1980) tables whenever the user has selected "Use API 11.1(2004)
F factor for CPL". Applies to 26.74.10 and up.
Report Setup
Four individual report template flags have been added for 26.74.10.
Allow a Daily Report Time of 24:00 for 26.74.10 and up - allow the
daily and auto-batch end contract time to be set to 24:00 so
that the date on the reports show the date the batch ended. A
time of 24:00 shows it ended at the end of the date shown on
the report.
Report Template Editor - expand the database point entry to include values
up to 18999 (was only allowing up to 17999).
Operate
Alarm Report - the number of alarm events has been increased from
150 to 500 for 26.74.10 and up.
Product Report - OmniCom was not retrieving enough of the report
from the Omni when four meter runs and eight products were
configured.
Archives 701-712 - Retrieval - the retrieval process was sped up for
26.74.10 and up.
Batch Control
Tree - there are now two selections: "Batch - Stack Shift" and
"Batch - No Stack Shift". The batches are ended with a shift
or no shift depending on the tree selection for 26.74.10.
Batch Stack - Enable editing for Level B users for 26.74.10 and up.
Level B Security - many registers necessary for the Operate functions

are now read-only allowed for Level B users in 26.74.10.


Help File
Temperature Configuration - the RTD DIN and American alpha values were
incorrectly listed as 0.0385 and 0.0392 instead of 0.00385 and
0.00392 respectively.
*******************************************************************************
Version 1.26 - June 18, 2007
Configure
Equipment Flags - equipment flag registers are now available in the
firmware for 22.74.06 and up.
Totalizers - added Totalizer Decimal Place settings for Gross, Net,
and Mass for 22.74.06 and up.
Physical Meter Setup - App 25 - Apply button not enabled when changing
ISO 5167 version selection.
Product Measurement Tables
GPA 27 23/24E tables were added for 22.74.06 and up.
API MPMS 11.1 (2004) tables were added for 22.74.06 and up.
Product Setup
An "API 11.1(2004) F factor for CPL" selection was added for the
API MPMS 11.1 (1980 edition) tables for 22.74.06 and up.
An "Use Separate CTL and CPL" selection was added for the API 11.1
(2004) Commodity Types tables for 22.74.06 and up.
The F-Factor entry is now grayed when the user selects the
Measurement Algorithm for API 11.1 (2004) Special Applications
as it is not used for applications 22 and 26.
The F-Factor entry is now disabled when the user selects the
Measurement Algorithm for Table 24C and also selects "API 11.1
(2004) F factor for CPL" for application 22 and 26.
Fluid Products - for the Ideal Gas Density Calculation Method, the
override compressibility, Z, was not being read or written to the
Omni from this screen.
Report Setup
Four individual report template flags have been added for 22.74.06
and up.
Allow a Daily Report Time of 24:00 for 22.74.06 and up - allow the
daily and auto-batch end contract time to be set to 24:00 so
that the date on the reports show the date the batch ended. A
time of 24:00 shows it ended at the end of the date shown on
the report.
App 24/25/26 - if the volume units are 'L', the mass units
automatically become "kg" in any applicable configuration screen.
Operate
Saving Reports - when the Save button is pressed and the user selects
their report name, if the file already exists on disk, the user is
now prompted if they would like to overwrite.
Archives 701-712 - Retrieval - the retrival process was sped up for
22.74.06 and up.
Batch Control
Tree - there are now two selections: "Batch - Stack Shift" and
"Batch - No Stack Shift". The batches are ended with a shift
or no shift depending on the tree selection for 22.74.06.
Batch Stack - Enable editing for Level B users for 22.74.06 and up.
Level B Security - many registers necessary for the Operate functions
are opened up for reading for Level B users in 22.74.06.
App 24/25/26 - if the volume units are 'L', the mass units
automatically become "kg"in any applicable operate screen.
Help File
Fluid Products - App 23/27 - added more information for AGA-10
calculated Isentropic Exponent
Reports - clarification on default report templates.

*******************************************************************************
Version 1.25 - May 4, 2007
Configure
General Setup - a "Status Screen Default?" check box has been added for
24.74.19 and up.
Omni I/O
Process Inputs - Input types were incorrectly being set to DP types
for non-orifice applications under certain circumstances.
Virtual Inputs 98-90 are now available for 24.74.19 and up.
Ports - Ethernet - configuration of the Omni SE module has been added
for 24.74.19 and up with Ethernet firmware v1.50 and up.
Meter Setup - Viscosity and Isentropic Exponent were incorrectly grayed
out for applications 21 and 25.
Physical Orifice Meter - removed the value check for the Disable
Isentropic Temperature Correction field in application 21 as it
does not apply.
Product Screen
An additional choice of Product DCF was added to the Density
Factor A and Factor B selection. A DCF for each meter
densitometer and the station densitometer was added for
24.74.19 and up.
Product Setup
Added pressure units to F Factor Override.
Corrected NGL Equilibrium Pressure units from absolute to gauge.
Configuration Print - Added a search feature so the user may search the
configuration print for certain items.
Operate
Prove Control
"Mass" and "kg" are now displayed for the first column heading for
Coriolis meters.
Level B access to meter type to determine if it is a Coriolis meter
is enabled in 27.74.20 and up.
The meter factor returned from the Omni was not compensating for
the Prove Report MF Decimal Resolution configuration. This
value is now auto-adjusted in OmniCom for firmware before
27.74.20 and up.
Batch Stack - Enable editing for Level B users for 21.74.02 and up.
WinPanel is disabled on the toolbar for the following operations:
Text Archive, Raw Archive, Prove Control, Batch Control, Batch
Stack, and Trapil Control as it was interferring with the
communications when closed.
Diagostics
Modbus Tester - Added an IP Address (IPv4) in dotted decimal data type
and added it to the convertor.
Help File
General Setup - corrected the help for Daylight Savings
Meter Type - clarified when the user may see the screen
Flowmeters
Turbine/PD - added information on Turbine/PD vs Coriolis meters.
Orifice - specified the revision of AGA 3.
Meter Setup - Added information on Turbine/PD vs Coriolis meters for
applications 20, 22, 24, and 26.
Prover Type - Added help on when compact provers are grayed out.
Auto Prove - Updates to auto prove introduction and flow rate change
% threshold.
Product - Measurement Algorithms
Ethylene API 11.3.2 - corrected the temperature range and other
minor corrections.
GPA TP27 - corrected the range limit and other minor corrections.
Fluid Products - Specify the Revisions of AGA3 and AGA5.

Boolean Statements - modified the User Defined Alarms section.


*******************************************************************************
Version 1.24 - March 6, 2007
Configure
Equipment List - GC checkbox - Apply was not disabled after pressed
if there was an Analyzer ID assigned but Port 3 was not configured
for an analyzer type and the GC checkbox equipment flag was not set.
Omni I/O - SV Setup - auto set SV meter types if known when opening a
file.
Meter Setup
Pulse Fidelity checking was added for Instromet UFMs for 27.74.20.
App 22/26 - Error Counts and Batch Warning were not being sent or
received for meter runs 2-4.
Instromet - added option for Primary Measurement Source for 27.74.20.
The options are Serial and Pulse. The default is Serial.
FMC MPU 1200 Setup - A series selection was added where the user may
select Series A or Series B for 27.74.30. The default is Series A.
Product Setup
An "API 11.1(2004) F factor for CPL" selection was added for the
API MPMS 11.1 (1980 edition) tables for 24.74.18 and up.
An "Use Separate CTL and CPL" selection was added for the API 11.1
(2004) Commodity Types tables for 24.74.18 and up.
The F-Factor entry is now grayed when the user selects the
Measurement Algorithm for API 11.1 (2004) Special Applications
as it is not used for application 24.
The F-Factor entry is now disabled when the user selects the
Measurement Algorithm for Table 24C and also selects "API 11.1
(2004) F factor for CPL" for application 24.
A Base Pressure (Pe) setting was added for the API 11.1 (2004)
Commodity Types tables. It also applies to any of the API 11.1
(1980) tables whenever the user has selected "Use API 11.1(2004)
F factor for CPL". Applies to 20.74.24 and 24.74.18 and up.
Fluid Products Setup
Add option to calculate Reference Density Using ISO 6976 for
27.74.20.
An option was enabled to add the neo-Pentane component to the
iso-Pentane or n-Pentane component or disregard it for 27.74.20.
- if one of the AGA-8 Detailed Methods for Natural Gas is selected,
this selection is available for the AGA-8 density calculations.
- if GPA2172 or any of the ISO6976 Heating Value Methods are
selected, this selection is available for the Heating Value
calculation.
- if a user selects fluid type NIST14, this selection is available
for the NIST14 density calculations.
SGERG Density Methods - "(1996)" was added to the Method
Descriptions for 27.74.20.
The fluid type for steam was incorrectly displayed as "Steam ASTM"
instead of "Steam ASME".
If the fluid type is Natural Gas with an ISO 6976 heating value
method selected, the base temperature is disabled. If you
switched to another fluid type, the base temperature was not
re-enabled.
If the user changed from Natural Gas which uses SG in SG units
(reg 17254), to another product which uses Ref Dens in kg/m3
(reg 17355), the register value was not being updated.
Analysis - GC Override mole percents - the screen always showed
Product 1's mole percents no matter which product you were on.
The database was updated only for Product 1 even if you were on
Product 2, 3, or 4. (The bug was introduced in v1.23.)
User Displays - the drop down for the resolution now shows the

corresponding number configured in the Omni. For example: "0.0"


was changed to "1 = 0.0".
Report Setup
Allow a Daily Report Time of 24:00 for 24.74.18 and 27.74.20 and up.
Allow the daily and auto-batch end contract time to be set to
24:00 so that the date on the reports show the date the batch
ended. A time of 24:00 shows it ended at the end of the date
shown on the report.
The Print Interval group was moved from Printer to Report Setup.
The "Checked/Proved For string" field for applications 22 and 26
was moved from the Printer to Report Setup.
Boolean and Variable Statements pages are now combined on one page.
Trapil Alarms and Training tab is now available in the Station
configuration for 24.74.18 and up.
Configuration Print - A line was added under the Omni version that
shows the version of OmniCom that was used when the file was saved.
Report Template Editor
Print and Save were added to the right-click menu when on the RAW view.
It prints or saves exactly what is on the view. The user may save
to any file name.
Operate
Batch Control
Tree - there are now two selections: "Batch - Stack Shift" and
"Batch - No Stack Shift". The batches are ended with a shift
or no shift depending on the tree selection for 24.74.18 and
up.
Batch Stack and Level B - Enable the Batch Stack editing for
Level B users for 24.74.18 and up.
Trapil Control is now available for 24.74.18 and up.
Prove Control
Corilolis Meters - display "Mass" and "kg" for the first column
heading. Level B access to meter type is enabled in 27.74.20.
The meter factor returned from the Omni was not compensating for
the Prove Report MF Decimal Resolution configuration. This
value is now auto-adjusted in OmniCom for firmware versions
before 27.74.20.
The Previous Prove data line not used in liquid curve applications
and was removed for applications 22 and 26.
Enabled for gas applications.
Diagostics
I/O Overview - Added limit checking on all physical inputs and outputs.
The program will not allow the process inputs to exceed 24 and the
analog outputs to exceed 12 for applications 20,22,24,26 and not
to exceed 18 for applications 21,23,25,27.
Modbus Tester - Allow a zero value for the register number.
The Data Values string for a User Defined message is now preserved
after a send even if it matches a known function code.
CRC selection Not Used - if the user provided CRC had an extra byte
at the end of the string - the program crashed.
CRC selection User Defined - it was not using the correct bytes for
the
CRC the user entered. For example: if the user entered a CRC of
"9E 5F" the program used "00 9E".
General
Press ALT-L on an edit field to display the range of the entry.
Checkboxes/Radios with integer registers - match the Omni firmware.
Only set checkboxes to 'Y' if set exactly to 1. Anything else is
'N'. Notify the user if the value is anything other than 0 or 1.
Communications
Connections via Ethernet - the ARP table is now deleted before

the connection is made to force an address resolution with the MAC


Address.
Help File
Meter - Flowmeter Type - the configuration settings in the Omni were
added for reference.
Product
- the content was clarified with regards to API@60 DegF, SG@60
DegF, and Reference Density overrides when using API 11.1 (1980)
versus API 11.1 (2004).
- NIST14 Reference Pressure was clarified with regards to entering
a positive or negative value.
- Measurement Algorithm corrections.
PID Loop - Tuning - Error Select setting - information was added on how
to make the best selection for the Error setting based on the user's
PID application.
Custom Data Packets
- added packet size limitations.
- added help for programming Boolean and Long registers for Modicon
compatible systems.
Peer-To-Peer - added packet size limitations.
*******************************************************************************
Version 1.23 - November 6, 2006
Configure
Omni I/O - Modules - Ethernet not match
Displaying an error message on Apply: "The ethernet setup serial
card types do not match the quantity of each serial card." It was
counting the modules that were hidden.
Ports - App 26 - Serial Port 4 - Protocol Type
Allen-Bradley should be at list top instead of at end:
0 - Allen-Bradley full duplex
1 - Allen-Bradley half duplex
2 - Modbus RTU
3 - Modbus ASCII
4 - Modbus RTU(Modem)
Meter Setup - range checking on Max Error Counts is only performed if
pulse fidelity is enabled.
Prod Setup - App 20 - F-Factor
The F-Factor entry is now grayed when the user selects the
Measurement Algorithm for API 11.1 (2004) Special Applications as
it is not used.
The F-Factor entry is now disabled when the user selects the
Measurement Algorithm for Table 24C and also selects
"API 11.1(2004) F factor for CPL".
Fluid Products - Setup - the fluid name was cleared when the user
changed the type selection. The order of the Fluid Type and Fluid
Name was swapped on the screen so the user first selects the Fluid
Type and then enters the Fluid Name.
I/O Selection - Invalid I/O assignment display
If an invalid I/O point assignment has been made OmniCom displays
"Invalid I/O - X" (where X is the assigned I/O point) and the entry
is colored red. (OmniCom used to set the assignment to zero and
display "Unassigned".) The following screens are affected: Aux
Inputs, Fluid Products Live Inputs, Meter Setup, PID Loop Config,
and all Density, Temperature, and Pressure screens where the user
selects an I/O point.
Receive All/Transmit All Configuration - App 27
The 2nd GC ID register 3877 and the C6 Distribution registers
7771-7775 were not being transmitted to or received from the Omni.
Operate
Control Tree - missing item/blank item on tree

If the equipment flag was not set for Meter Run 4, the text from
the last tree item was missing and the item was unusable.
Reports and Text Archive with VSAT comms
The communications were defaulting to a 500ms time out instead of
using the user defined time outs set in the Site file. For
Ethernet with VSAT communications 500ms was not long enough
and caused duplicate lines and garbage on the reports.
Batch Stack and Level B - App 20 - Enable the Batch Stack editing for
Level B users for 20.74.23.
General
Edit Serial Passwords - Log user on "internally" when Level A is
ammended. When a user modifies or assigns a new Level A password
in this screen, the Omni logs them on with that password. OmniCom
now also logs the user on internally so that they will be logged
off when the program ends or if they go offline.
Allow Level B users access to change their passwords.
Help File
Edit Serial Passwords - more help was added.
Boolean Statements - more help was added for the Rising Edge, Falling
Edge, and One-Shot operators.
Custom Data Packets - in the main Custom Packet help, the links to the
individual packets help (Modbus Packets 001, 201, and 401) were
added.
Archives 701-710 - a note was added regarding using momentary Boolean
Triggers.
Diagostics - Modbus Tester - Diagnostic Code - the help was clarified
when describing which entry is required (Data Register vs.
Diagnostic Code). Help was also added for the Omni 3000/6000
specific requirements for the Diagnostic Code and Diagnostic Value
fields.
Report Setup and Archive Configuration - clarified text on Detailed
Daily Report.
*******************************************************************************
Version 1.22 - September 8, 2006
Configure
General Setup - Factors and Systems Constants
Added a conversion factor for "g/cc to lb/ft3" for 20.74.22 and up.
Atmospheric Pressure for applications 22/26 was not being written
to the Omni on apply.
Product Measurement Algorithm - Addition of Anhydrous Ammonia for
20.74.22 and up. flow rate units become Tons/Hr, batch preset
warning is in Tons, prover volumes are in LBS and K-Factor is in
pulses/gallon.
Product Setup
An "API 11.1(2004) F factor for CPL" selection was added for the
API MPMS 11.1 (1980 edition) tables for 20.74.22 and up.
An "Use Separate CTL and CPL" selection was added for the API 11.1
(2004) Commodity Types tables for 20.74.22 and up.
Meter Setup
The Alarm Meter Inactive and the Active Frequency settings are no
longer available until a flow I/O point is assigned.
If the meter type is an ultrasonic, the Model, Size, and S/N are
enabled even if a flow I/O point is not assigned.
K-Factor & Meter Factor Resolution
The 12 K-factor curve entries for applications 20/24 and 23/27 are
now limited to 7 significant digits.
The single K-Factor entry for applications 22/26 is now limited to
7 significant digits maximum.
The meter factor on the Product page for applications 20/24 has
been modified to allow entry of 7 significant digits instead of

limiting the entry to the selected resolution of 4, 5,or 6.


The meter factor on the Meter Setup page for applications 21/25 and
23/27 is now limited to an entry of 6 significant digits.
The 12 meter factor entries on the MF Curve page under Products is
now limited to 7 significant digits instead of limiting the
entry to the selected resolution of 4, 5, or 6.
Batch Scheduling - added an option to disable the shift of the stack on
on auto-batch end for 20.74.22 and up.
Report Setup - allow a Daily Report Time of 24:00 for 20.74.22 and up.
Allow the daily and auto-batch end contract time to be set to 24:00
so that the date on the reports show the date the batch ended. A
time of 24:00 shows it ended at the end of the date shown on the
report.
Receive All/Transmit All Configuration
App 23 - for FLOWSIC meters, the measuerment status digital input
for Meter Run 1, register 3163, was not being read/written.
Operate
Batch Control
Tree - there are now two selections: "Batch - Stack Shift" and
"Batch - No Stack Shift". The batches are ended with a shift
or no shift depending on the tree selection for 20.74.22 and
up.
Anhydrous Ammonia - volume units are in Tons with two decimal
positions.
There was no decimal place showing for the Mass Totalizer for
application 22. It is now fixed at 3 places.
Prove Control
Added a display of the the proving meter's Net or Mass real time
flow rate depending on the pulse type. Also shows the Master
Meter's flowrate for Master Meter proves.
Anhydrous Ammonia - flow rate units are Tons/Hr with two decimal
places, volume units are LBS, and density units are lb/ft3.
Help File
Configuration
Product Measurement Algorithm - Added help for Anhydrous Ammonia.
Coriolis Metes - added additional help regarding flow pulse type
and K-factors.
Meter Types - FLOWSIC 6000 - updated the fields with more
information and added a note regarding the new FLOWSIC v2.0
hardware.
Meter Run Setup - applications 21/25 - Added help for Viscosity
and Isentropic Exponent.
Physical Meter - Orifice - added help for Venturi Pressure Loss %.
Station Setup - added help defining the meter runs that will be
part of the Station and how they impact the Station Common
Batch Stack and Station Batch end command.
Station Interface Detection - updated the help for gravity
"Rate of Change" and "Line Pack Delay".
Prover Characteristics - added help for the Linear Coefficient
(Invar).
Boolean Statements
The "Timer Compare" and "Exact Compare" were removed.
The "Timer Function", "Rising Edge", "Falling Edge" and "One
Shot" help and examples were upated.
Variable Statements
The "Rising Edge", "Falling Edge", "One Shot" and the
"Range Checking" examples were corrected.
Batch Scheduling - added additional help for setting up the batch
end time and a note regarding ending the batch for a station.
Reports - added help for the Daily Report Time of 24:00.

Operate
Batch Control
"Batch Schedule" tab title was changed to "Batch Stack".
Added help on Batch Stack Shift/No Shift option.
TroubleShooting - Troubleshooting Ethernet Connections - made
corrections to the interrupt settings (IRQ).
*******************************************************************************
Version 1.21 - June 6, 2006
Configure
Equipment List - Prover flag not checked - App 26
The prover equipment flags were not being auto set even though
there was a valid prover I/O for firmware 26.74.03.
Process Inputs - Density Pulse - Apps 23 and 27
When setting up the input channel for a gravitometer or a
densitometer for gas, the override option 5 (Use product override
on transmitter fail) should not have been allowed.
Meter Type and Setup
Added support for FLOWSIC 600 Ultrasonic Meter for 23.74.20 and up.
Meter Setup - Pulse Fidelity - Apps 22 and 26
The Apply button was not being enabled when the pulse fidelity
setting was changed. If other items were changed on the screen and
the Apply button was enabled because of the other changes, the
pulse fidelity change was not being saved or sent to the Omni.
Prover - Auto Prove Setup - incorrect Flow Stable Period Units
The flow stable period units are now minutes instead of hours.
Product Meas. Algorithm - Propylene Mole Fraction
Under the Olefins section, if the Propylene Table is selected, the
Mole Fraction of Propylene is now automatically set to a value of
1.0000 in the corresponding Modbus address for the product
(17235-17250 for Products 1-16 respectively). The Mole fraction
is displayed in the Product Setup tab.
Product Setup - Water - Correction for Dissolved Air
OmniCom was not in sync with the Omni when setting the flag to 'Y'
or 'N'. The Omni sets the flag to 'Y' only if the value is equal
to 1.0. OmniCom was setting to 'N' if value was equal to 0.0.
Fluid Products Setup - Heating Value Methods - app 27
Added support for additional ISO 6976 Heating Value Methods for
different Base Temperatures. Moved the single Base Temperature and
Pressure entry from the Factors and Systems Constants page to the
Fluid Products Setup page - one set for each product. Applies to
27.74.19 and up.
Receive All/Transmit All Configuration
Factors apps 22 and 26 - the Batch and Prover Report Correction
factors use the old registers of 13107 and 13106 respectively.
They were being handled OK in the Decimal Resolution page but
not being received or transmitted via configuration.
Default Templates - the single Default Template Flag from an older
version file was not being written to the four individual
Default Template flags before transmission to an Omni with a
newer firmware version that had the four individual flags.
Report Template Editor
Insert Printer Code - a new entry was added into the existing
right-click context menu to insert a user defined printer control
code. This is analogous to the "Ctrl-Q" feature in OmniCom for
DOS.
Form Feed Token - the <FF> token, as all other defined tokens, was
removed from the "Report" view.
Insert DBPoint/Boolen Block - it was defaulting to the previous insert
value preventing consecutive inserts of the same value even if the

user was on a different report. It now clears the value on insert.


Diagnostics
WinPanel - when Large Fonts Enabled on PC display, the Omni text
display was larger than picture of Omni panel.
Communications
Modem Disconnect Screen - if the serial cable to the modem was
disconnected, OmniCom exited, and the ESC key pressed on the
Disconnect Screen during the "Hanging Up Retry..." message there
was an abnormal program termination.
View Comms Log - occasionally comms were missed when viewing or
clearing a large log.
Edit Site List - added a message to notify the user if the configured
COM port does not exist and that the program is defaulting to the
first COM port in the drop down list.
Setup Units - increased the Direct comms default initial delay from
500ms to 1000ms and Modem comms from 1000ms to 1500ms.
Password dialog crashed program when TCP Password enabled for Ethernet
port configured for ASCII protocol.
Help File
Configuration
Orifice Physical Meter - Added some extra wording for the Cmp and
dZ/dT inputs on app 27 Orifice page regarding entering a
negative value.
Prover - Auto Prove Setup - added units to text for flow stability
time.
Product - Measurement Algorithm - Propylene table - added help
regarding the Propylene Mole Fraction auto set to 1.0000 when
table selected.
Fluid Products Setup
Added ISO 6976 additional Heating Methods with Base Temperature
and Pressure.
The reference to Solartron for the signal type was changed to
specify Solartron "3096/3098" so that the customer knows
that these models of Solartron are gravitometers and not
densitometers and can configure them correctly in the Omni.
Gas Chromatograph Setup - explained what happens when the option
"Use GC2 on GC1 Failure" and "Always use GC2" goes into effect.
Gas Chromatograph - Components - neo-Pentane 7005 - changed the
comment to "add this component in the GC to i-Pentane component
before it is read by the Omni. Neo-Pentane does not exist in
AGA 8 or AGA 5".
Report Template Editor
Added the Insert Printer Codes addition.
Clarify the Common Batch Stack variable in Station Setup, Batch Setup,
Op Batch Control, and Op Batch Schedule.
*******************************************************************************
Version 1.20 - March 15, 2006
Configure
Default configuration file creation - apps 24, 25, and 26.
Default the Product Reference Temperature to 15.0C for new files.
Equipment Page - GC checks re-appeared after Apply
If an ID was assigned to a GC in the GC Setup page, the Equipment
list checkbox check could not be removed without first going to
the GC Setup page and clearing the ID. Added the option to
auto-remove the assigned GC IDs if the user would like to
uncheck the boxes.
Meter Type and Setup
Added support for FLOWSIC 600 Ultrasonic Meter for 27.74.19 and up.
Meter Setup - units on flow rate limits were not correct.
Added a checkbox to disable NIST flowing density calculation. The

addition applies to 23.74.20, 24.74.18, and 27.74.19 and up.


The units on gas applications (23, 27) were volume instead of mass.
Liquid Turbine meter applications (20, 24) were always showing
volume units. Now it shows volume units unless the user has
checked "Use Mass Pulses" box and then it shows mass units.
Krohne VOS field was not displayed in the correct place.
Station Setup - Batch Preset Warning was removed for gas apps.
SV Setup - the SV port types were configured in the I/O section but
the ports were not availble in the Meter Type specific
configuration page. Additionally, if the SV ports were configured
in the Meter Type specific page they were not shown in the SV Setup
page. When online, after a read all config, it did not enable the
SV port types in the SV Setup for SV ports that were already
configured for a meter.
Variable Statements - item in selected box was copied when using mouse
wheel to scroll back up.
Report Template Editor
Crashed on Win 98 or NT 4.0 when a template was opened.
Operate
Reports
Save File Name - instead of saving two files, the user may now
select the save file name - Computer ID (DOS or Date/Time) or
File Name (DOS or Date/Time). The Reports File Viewer defaults
to last selected file name type.
Batch, Daily, and Prove - there are 8 reports stored in the Omni
for each of those items. OmniCom saved the reports with
"PVR1", PVR2"... "PVR8" in the name. The number was removed so
now the name is "PVR". (The reports saved with the DOS
extension still have the number in the extension.)
Tree Item "Alarms (500)" title not correct for apps 22 and 26 - the
title was changed to "Alarms (150)".
Archives View now uses WordPad instead of NotePad due to possible
size limitations of NotePad.
Help
Configuration
Meter Run - Added help for the FLOWSIC 600 Ultrasonic Meter.
Report Setup - now tells where to go to activate the Detailed Daily
Report
Batch Setup - added connection between common batch stack and
station.
Operate Reports - added information about the Save Reports File Name.
*******************************************************************************
Version 1.19 - February 7, 2006
Configure
Default Configuration - Liquid applications
Default the station and prover density factors to 1.0 on new files.
Process Inputs - Liquid Orifice applications - configuration of flow
pulse types are not allowed.
Ports
Hardware - if Port 5 is selected as Ethernet and Port 6 is serial,
baud rate 57600 for Port 6 is not allowed.
Meter
Meter Setup - Use Live Density checkbox for App 24
Added water to the title
Is visible only if density/gravity is selected in the Equipment
page for the meter.
Daniel Ultrasonic - App 27 - a DFI Retry Timer was added.
Prover
Prover Type - Two-Series Bi-Directional Pipe not allowed for
App 24.

Prover Operation
The maximum runs is limited to 5 for Two-Series Bi-Directional
provers.
Run Repeatability label was incorrect for apps 20 and 24. It
showed (Max - Min)/Avg and is now (Max - Min)/Min.
Products
Measurement Algorithms and Setup now support NIST14 and water for
app 24.
Fluid Products
NIST14 is now supported for App 27.
Gas Chromatograph Setup
App 27 - Added Danalyzer Type selection (USA or UK)
Anaylysis and Gas Chromatograph Components
Correction for formula for n-Octane C8H18 (was shown as C8H16).
Archives 701-710 - Detailed Daily Report
If the DDR box is checked while offline, auto-configure
Archives 701-705.
Transmit All Configuration
Current trigger values in the Omni were lost on transmit all when
archive configuration was disabled.
Operate
Archive Maintenance - screen not reflect changes
The delay after the archive is set to "running" has been increased
again to account for the extended RAM processing time.
Prover Control
Total Counts showing same value as Run Number. (Bug introduced
in v1.18)
Fixed determination of prover active.
Display the last proved/current meter on startup in the meter drop
down box.
Two-Series Bi-Directional provers - Show the set of runs for the
first series and then the set of runs for the second series.
Density label incorrect for App 24 - "Den@15C" should be "Den@Ref"
for meters running products with water or NIST14 product
algorithms.
Density decimal places should be 1 for App 24.
Zeros were showing for temperature, pressure, and density when the m
eter
run was changed and the prover mode was different for the meter
runs
(i.e. mass vs. volume).
Communications
Total message lengths limits were set according to Modbus standards:
256 bytes for RTU messages
256 + 6 bytes for Modbus/TCP messages
513 for ASCII messages
Modbus/TCP message length was incorrectly limited to 255 bytes instead
of 256 bytes (not including the Modbus/TCP header bytes) because it
was only using one out of the two bytes for length in the
Modbus/TCP header.
General
Applications 22.74.05, 26.74.02, and 25.74.00 and up are now supported
with OmniCom.
Edit Control Display for float numbers
Very small numbers were showing in exponential notation and
incorrectly.
Help File
Product Measurement Algorithm page - the Omni Table Select Values were
added for convenience.
Fluid Products - Setup - Fluid Properties - Viscosity - the units were

added for application 27.


*******************************************************************************
Version 1.18 - November 16, 2005
Configure
Equipment Flags
For firmware revisions that do not have the equipment flag
registers, the Prover Equipment Flag will be auto set if any
of the prover I/O are configured.
The prover tree item was not visisble when the Enable Prove box
was checked for gas applications.
Ports - Protocol
Apply had to be pressed twice before changes to the CRC Detection
checkbox took effect when online.
Archives 701-705
Detailed Daily Report can be configured in Archive 701 with
firmware 23.74.19 and up.
Import DOS Configuration
If the DOS Omni configuration file being imported had a lower case
extension (*.omi), the DOS configuration file was copied into
the new templates.
Transmit All Configuration
Serial Port 1 Port Type (Printer/Modbus) was not being written to
the Omni.
Report Template Editor
The file filter on the Open File dialog was not defaulting to the
correct application in the template extension when importing a
template.
Operate
Batch Control
Flowing Density for liquid applications was the incorrect register
(displaying register 7107 instead of 7109).
Level B security
There were some new registers being used that were not yet Level B
enabled in the firmware. Those new registers are skipped
for the older versions of firmware for Level B users.
The Batch Schedule page was removed from the Batch Control for
Level B users.
Diagnostics
I/O Overview
Density Pulse type Process Inputs are now divided by 1000 before
display.
Process Inputs on H, HV, and SV cards first have 8,000,000
subtracted and it is divided by 100 and displayed as a
percentage.
The size of the display field was increased as some Process Input
values were cut off.
General
Help File updates.
*******************************************************************************
Version 1.17 - October 7, 2005
Configure
System Date and Time
In the offline mode, the date and time of the last received
configuration is displayed.
Editing System Date and Time might not reflect change. The Omni
needs at least one second to process date and time changes.
OmniCom was reading too soon and sometimes it appeared as if
the Omni had not accepted the change.
Modules - One serial port
If online and there is only one Serial or SE Module, the program

uses the "live port" (the port the connection is made on)
to determine if ports 1&2, 3&4, or 5&6 should be enabled in
the configuration tree. (If in offline mode, the user may add
additional Serial or SE Modules in the Modules page to enable
the ports to configure in the configuration tree.)
Process Inputs
Density Units for non-pulse types - if adding a density process
input that is not yet assigned a 'type', the units are now
blank until the type is known. A message is displayed in red
guiding the user to the Help file for information on the units.
SV Module Process Inputs allocation - OmniCom always counted 12
process inputs per SV Module. This has been changed such that
the process input is only allocated if one of the ports on the
SV Module is configured for the Rosemount protocol. The user
in now able to configure any SV Port for an SV Process Input
that has the Rosemount protocol regardless of whether the
Process Input is shown under the tree for that module
(SV-1 or SV-2) that contains that port.
SV Setup Page - The SV Port Protocol types are automatically set based
on the meter types and SV Ports configured for the meters.
Ports - Ethernet Setup - Modicon Compatiblity was added for 23.74.19,
24.74.17, and 27.74.18.
Meter Setup
Added Krohne VOS as Aux 'n' for Krohne Ethylene fluid types for
application 27. This field is only displayed if the user
selects a product which is a Krohne Ethylene fluid type.
K-Factor Curve page - Changes made to the first frequency while
online were not getting written to the Omni if that was the
only frequency changed before Apply was pressed.
V-Cone for application 23 - V-Cone Reynold's numbers and Flow
Coefficients were not written to the unit when a file was
transmitted to it.
Density Setup - type and source checks
If a Density I/O point is assigned to one that is already used
elsewhere, the density type and source are carried over from that
previously used I/O point. If the density type or source is
changed, the type and source are changed whereever else the I/O
point is used.
Product
Measurement Algorithm - 20.74.14 and up - added NGL table
select 40 for Product 1 & 2 only.
Product Setup - if NGL table 40 is selected, added entries for K0,
K1, and Equilibrium Pressure.
PID Tuning - Response - Gain Factor - range checking - low end range
value was incorrect. It was 0.1 to 99.99 and now is 0.01 - 99.99.
Archive 701-705 configuration - Application 23.74.10 and up - if the
Detailed Daily Report is activated, configuration of Archives
701-705 is disabled except for the max records, and text is shown
in red indicating archive memory is being used for the detailed
daily report.
Printer Setup - The HP Laserjet default normal mode string was set to
an HP Reset string (1B45) instead of the HP Single spaced mode
(1B266B3053).
User Displays - Added Import/Export to file
The user can right click on a any User Display page and a menu
appears with the following utilities:
Import User Displays...
Export User Displays...
Transmit All User Displays...(only if online)
Configuration Print causes OmniCom to crash

A resolution in the User Displays was out of range and the program
crashed when it tried to format the resolution. The reslolution
range is now checked before displaying.
Report Template Editor
Report Template Editor Tree - added a context menu
The user can right click on a template in the tree and a menu
appears with the following template utilities from the File menu:
Import Template...
Export Template As...
Import an OmniCom DOS Template File...
Added support for the 'E' format specifier set in the precision field.
Importing OmniCom DOS Template - crashed when width out of range.
Added range checking on width and precision. Notifies user of
point number and error.
Operate
Reports
The Product and Status Reports were moved from Historical Reports
to Current Reports on the tree list.
When viewing a report that has been retrieved by the unit, the
form feed control code now appears as a page break.
Added a "View Saved Report" button. The reports are now available
offline in the Operate tree. When offline, it automatically goe
s
into the View report mode (as that is the only button available
offline).
The Abort button was added when communicating online so the user can
terminate the automatic report retrieve.
Included more information for the user when there are errors.
Archive Data Retrieval
Now uses Computer ID for file name instead of using configuration
file name.
Better file and folder error reporting have been added.
Better communication error processing has been added along with a
chance to continue with the retrieval.
Text Archive retreival - Sometimes came back with records when there
were no records.
Archives 701-712 - Retrieval
Sped up the retrival process for applications 20, 21, 23, 24, 25,
and 27.
The current record number being read is shown on the Apply status
message.
The "Abort" button is enabled when reading browser date and time
stamps and when retrieving archive records.
Not appending file data correctly - if the box for "Append to
existing file" is selected, only records that do not already
exist are added to the file in the proper position using the
date/time stamp. For Alarms (711) and Audit (712) there may
be records with the same date and time so an additional field
is added to the check. For Alarms (711), it uses the Modbus
ID, for Audit (712), it is the event number.
The blank line at the top of the file was eliminated.
Archive Maintenance - screen not reflect changes
The delay after the archive is set to "running" has been increased
to account for the extended RAM processing time.
Batch Control
The current batch meter factor is displayed next to the current
batch product.
Batch units now match batch preset units reg 3099 (gross, net,
mass).
Batch Remaining

Units were missing.


The value was not going negative after passing zero resulting
in huge numbers on the display.
Metric apps only - the value should have the same resolution
as the totalizer that matches the selection made for the
batch preset units (gross, net, mass).
Prove Control - "Density At" units
For 24.74.17 and up, for products that use the API 11.1 2004
table, the "density at" units are "60F" instead of the usual "15C".
Diagnostics
Modbus Tester
Allow Broadcast messages - the user may temporarily change the
Modbus ID to zero for broadcast messages. Broadcast messages
are only for function codes that do not require a response.
Processing of 8-bit data types were not being processed correctly
for function codes Reads (03 and 04) and Writes (06 and 16).
Communications
Receive All/Transmit All Configuration - the Omni unit's
application, version, revision, and/or checksum is re-checked
before every RX or TX all configuration to make sure it has not
changed.
General
Application 21.74.00 and up is now supported with OmniCom.
Importing DOS Configuration files the corresponding DOS templates are
also imported automatically.
The last folders used are now saved for the following actions:
Config Open or Save as, Import Template, Export Template,
Import DOS Config, Import DOS Template. Each time the
user does one of those actions, the file path returns to the last
used folder.
New Files - set default values on creation
The default values the Omni sets on RAM reset are now set for
OmniCom when a new file is created. Note: There are some values
that are still under discussion: Base Temperature, Base Pressure,
Prover number of runs to average and Prover Overtravel.
Opening incompatible files
If a normal file open is performed on a DOS configuration file, or
while in the Config tree a normal file open on a DOS template
file, the Child window closed and it was left with just the Main
Frame window. It now comes up with an informative file format
error message and leaves the Child window in place. The error
messages were also changed for opening incompatible files while in
the template tree.
Help file updated.
*******************************************************************************
Version 1.16 - May 31, 2005
Configure
Ethernet Setup - Modicon Compatible checkbox added. SE firmware 2.0
temporarily disabled.
Fluid Products Setup - Density Method for Ideal Gas Calculation added
and NIST14 fluid type and component analysis basis added for app
23.74.19 and up.
NIST14 Component Analysis page added.
Prover Operational Setup - giving a range check error on gas apps for
unused density stability time.
Printer Setup - Removed the "$" delimeters in the printer codes.
Orifice and VCone Physical Meter Run - Expansion Coefficient could have
two radios buttons on at the same time causing confusion.
General
Help file updated.

*******************************************************************************
Version 1.15 - April 25, 2005
Configure
Prover Operation - An "Archive all reports" flag was added.
Reports - The single "Use default report template" configuration item
from a configuration file did not import properly into the new
multiple "Use default" for each report configuration items.
Digital I/O - Pulse Outputs - if the pulse width or pulse per unit was
changed, the pulse width or pulse per unit field was cleared by
the Omni.
Peer To Peer Setup - if redundancy is selected, the Next and Last
Masters fields are disabled. The Configuration Print was modified
so those fields do not show when redundancy selected.
Process Inputs, Current Assignments, and the Configuration Print - DP
Mid Range I/O points display in applications that don't support
stacked DPs if a prover density temperature I/O point is assigned.
Meter Setup Screen - range error on the pulse fidelity related fields
when pulse fidelity is not enabled. The Configuration Print was
modified so those fields do not show when pulse fidelity is not
selected.
Reports Template Editor
Copy/Cut/Paste/Undo functionality is available in the FORMATTED and
RAW views. The toolbar and context menu for Copy, Cut, Paste, and
Undo is enabled. The Control-C, Control-X, Control-V, and Control-Z
edit keystrokes are enabled.
File import error display has been added to the status bar (left side).
Import error message boxes now indicate the report type.
Operate
Operate Prove Control - total counts column was expanded because it was
truncating large values.
General
DOS Configuraton Import - Text fields can contain garbage.
Processing added to filter out unprintable characters during a
configuration import. Unprintable characters are replaced with a
SPACE character.
Save As - Changed to use the current path. Removed the setting of a
fixed save file path to the installation directory for file saves.
Help file has been updated.
Communications
Connect Screen - the Connect button is disabled when the user is on a
site.
LEDs - Sometimes the red or green LED would not blink.
*******************************************************************************
Version 1.14 - January 19, 2005
Report Template Editor - Added the "Text Files (*.txt)" file filter item
to the "Import OmniCom DOS Report Template" file open dialog for all
template editors.
Transmit All - Audit log wasn't being recorded.
Communications
Comm ports were always truncated to 1 digit on connect. For example if COM41 was configured for a site it would try to open COM4.
Modem not initializing - Dell Latitude D600 - Conexant D480 MDC 4.9x
modem - always gave "Invalid Response" message.
Modem Connect Screen - Allow modem connection even if the modem connect
baud rate doesn't match the baud rate configured for the modem
serial port.
Modem Disconnect Screen - sometimes hung if the phone was physically
disconnected before disconnecting via the Disconnect Screen and
modem echo was enabled. If the user pressed the ENTER key
sometimes it would abnormally terminate the program.

*******************************************************************************
Version 1.13 - November 16, 2004
Meter Configuration - AGA 11 for mass meters - added Coriolis Meter type
for gas applications.
Meter Setup, DP Setup, and Process Inputs Screens - added Stacked DPs for
gas apps - DP Mid range I/O added.
Serial Port Protocol and Ethernet Setup Screens - added Live Port
indication.
Operate Report File Save - now saved twice - one with OmniCom for DOS file
extension in "install folder\Reports" and the OmniCom for Windows file
in "install folder\Reports\Archive".
Operate Text Archive - reworked the retrieval process to support both Omni
firmware revisions up to 2x.70 and revision 2x.71 & later.
Added an initialization step to zero the Days register prior to each
retrieval to initialize the flow computer firmware for the retrieval.
Updated help file.
*******************************************************************************
Version 1.12 - October 15, 2004
Process Inputs screen - Honeywell DE signal type for H and HV boards is now
Analog Input/Honeywell DE" type and allow input scaling fields to be
entered and viewed throughout the system.
When opening an existing file made with a previous version of OmniCom,
it will change the Honeywell DE signal types to Analog Input type.
Meter Setup screen would only allow H and HV board DP I/Os for Honeywell
meters (meter type = 3). Now it allows H board DP I/Os for Orifice and
V-Cone meter types and only HV board DP I/Os for Honeywell meters.
Auxiliary Inputs Screen - Aux inputs 2-4 were only writing the new I/O
point and not the rest of the information that goes with the new I/O
such as tag and type, etc...
Configuration Print - if an I/O point is zero or out of range it just shows
"unassigned" and no more information.
Transmit Check screen - items that don't match before a file is transmitted
to an Omni is now highlighted in red for easy detection.
Level B and C passwords - Updated the firmware revision levels checks so
OmniCom can determine if level B and C changes are applied or if it is
a previous version of firmware.
*******************************************************************************
Version 1.11 - September 3, 2004
A right-click context menu for Cut/Copy/Paste/Select All was added to the
Archive Configuration, Custom Packets, Allen Bradley Packets,
Boolean Statements, and Variable Statements.
Disabled the Drag/Drop and Cut/Copy/Paste functionality whenever the
edit mode is disabled (i.e. Archive Configuration when the Archive
is running).
Density - Solartron Setup - firmware 23.74.17 and up and 27.74.16 and up.
New Cal Gas Offset Data. Constant K5 becomes the Cal Gas Constant.
A new field, SP. Heat Ratio, has been added.
Importing OmniCom DOS Files
The product meter factors for apps 20 and 24 were not being imported
correctly.
The Batch Preset Warnings for all apps (except 23 and 27) were not
being imported correctly.
File open and connecting to a unit with a different app.
If you have a file open and you are connecting to a unit with a
different application than the file, a message has been added to allow
you to close the file and continue with the connection or go offline
and continue with editing the file.
Operate - Batch Control
The Batch Adjust for station when common batch stack was not updating
correctly. Also, when common batch stack, batch adjust was removed for

the meter run screens.


Operate - Batch Control and Prove Control
The Apply and Cancel buttons were being enabled and resulting in the
message "Would you like to apply your changes" coming up. Those
buttons have been removed as they are not used.
Operate - Text Archive Retrieval
The user was asked if they would like to apply changes but the Apply
button doesn't apply to that screen.
Level B and C passwords - requires a corresponding firmware update.
OmniCom uses more registers for the report template and operate
functions than the DOS version did. OmniCom was getting stuck in the
communications when it tried to access a register that required
password entry.
Edit Serial Passwords - Added a checkbox for each level to allow blanks
to be entered to clear the password.
Edit Sites
You can now double click on a unit to edit the unit directly instead of
first going to the Edit Comms screen. After the edit complete, the
edited site is expanded and the edited unit is selected.
Connect Screen - double click on a site or select a site and press Connect,
the site is expanded or collapsed instead of a message displayed.
Archive Configuration - the Record Size/File Size was not being
updated upon a data Drop or Paste operation.
The configuration was changed so that the Record Size and File Size are
updated as data is entered into Point No. or Point Count.
Meter Run - Flowmeter - Setup
Fixed the Apply button enable logic for the "Active Frequency". For
example, if the "Alarm Meter Inactive" checkbox is unchecked, entering
a zero (assuming it was previously non-zero) did not enable the
Apply button.
Meter Run - Physical Meter - Orifice DP
Apply button still enabled after Apply pressed when the Disable
Isentropic Temperature Correction flag was changed.
*******************************************************************************
Version 1.10 - July 26, 2004
Configure
Process Inputs - if offline and had set up a DP low and high I/O,
assigned to a meter run and then edited the high I/O via the
Process Inputs page, the DP Low Override code and value and the DP
Low alarm low and high values were cleared.
Damping units were not being shown.
Fluid Products - Setup - Water Content value not shown for
Redlich & Kwong density method - app 23.
Meter Setup Rosemount meter types - only allow DP I/O points from an SV module.
Honeywell meter types - only allow DP I/O points from H or HV module
s.
Checks meter type before allowing pulse fidelity.
Low and High alarm limits were always blue - now only if configurabl
e
as in app 24, 25 or 26.
Rosemount and Honeywell meter types - missing the DP Setup and
Physical meter run pages.
Orifice - pointing to orifice diameter in database instead of reference
orifice diameter. Inside diameter label was "Expansion Coefficient"
.
Expansion Coefficients incorrect for metric applications 25 & 27.
FMC Setup - flow direction was not being saved on Apply.
Prover - Operational Setup - Gas apps - if a mass prover, flow rate
units were volume instead of mass.

Reports - Added four new "Use Default Template" flags.


Boolean and Variable Statements - a row drag/drop cut, copy, paste
facility was added.
Allen-Bradley not showing register on ALT-M press when individual item
selected.
Archive Configuration - the Apply button was re-enabled when either the
Boolean Trigger or Max Records edit box was updated while the size
limit was exceeded.
Reports - the apply button was re-enabled after an I/O error.
Null bytes were terminating the report retrival process.
Premium Billing - station register address in database was incorrect.
A Configuration Print utility was added to the Configuration Tree.
Operate
Archive Maintenance - if the archive was started, a delay is
invoked to allow time for the flow computer to finish allocating
the archive memory prior to reading and displaying the allocation
results. A status message is presented on the apply bar during the
delay time.
Text Archive Retrieve - Fixed problems in the retrieve logic such that
whole day records are now retrieved and saved. Other retrieval
problems have been resolved.
Historical Report Retrieval - Some problems with data retrieval have
been resolved.
*******************************************************************************
Version 1.09 - June 23, 2004
Configure
General Setup - Equipment List - when flags set for MR 2-4 it would
assign their meter I/O points to the DP I/O points of MR 1-3
causing invalid DP Process Input assignments.
Sometimes the Apply button was continuously enabled even after
Apply was pressed.
Process Inputs and DP Setup - The incorrect DP unit was showing for
Metric applications.
Meter Run
Flowmeter
Instromet - using incorrect register for AGA 10 VOS for app 27.
FMC Setup - using incorrect register for AGA 10 VOS for app 27.
Density Setup - removed Denisty Factor B.
Prover - Operational Setup - increased range check on number of passes
from 1 to 10 to 1 to 25.
Product Setup - Added Use Observed Density flag for Special Application
for applications 20 and 24.
Fluid Products - Setup - Critical Pressure units now in blue for metric
apps.
Range limitations on the Critical Temperature and Critical Pressure
entries for Redlich && Kwong Method have been removed.
Added show of register number on ALT-M press for display only fields on:
Process Inputs - for the first assigned item in the list.
Aux Inputs
Meter Run - Setup, DP Setup, Temperature, Pressure, Density,
Density Setup, Density Temperature, and Density Pressure.
Station - Density, Density Setup, Density Temperature, and
Density Pressure.
Prover - Inlet/Outlet Temperature, Inlet/Outlet/Plenum Pressure,
Density, Density Setup Density Temperature, and Density Pres.
Fluid Products - Live Inputs SG, HV, N2 and CO2.
Archive configuration not showing register on ALT-M press when
individual item selected.
Operate
Text Archive - sometimes would complete reading but not report back

status and all buttons remained grayed.


General
Removed the request of the revision number for new file opens.
If have a file opened for one application and connect to a unit of a
different application, the board types of the file were being
applied to the connected unit's data.
*******************************************************************************
Version 1.08 - June 2, 2004
Configure
General Setup - Factors and System Constants Added MJ/m3 to Btu/cf (reg 7855) for 23.74.13 and up.
Station - Configuration and Setup - Setup - blank station definition
was not allowed.
Prover Characteristics - Modulus of Elasticity - was using English
range for metric apps.
Report Template Editor
Prove Report Templates not being read/written for gas apps 23 & 27.
General
File Import for v74 files saved with OmniCom DOS has a different format
for "application.version.revision". Now saves checksum, too.
Default Settings file (OmniSettings.dat) that comes with the install
was opening with a default 20.73 (now it is 20.74.12).
Help file
Test Communications - Added help on ASCII strings.
*******************************************************************************
Version 1.07 - May 19, 2004
General
New file saves - default to executable path.
Tree item - Meter Runs 2-4 - Configuration item was being shown on
the tree for non-orifice applications.
Windows 98 installations - help file, settings file, Release Notes,
User Notes path corrupted.
*******************************************************************************
Version 1.06 - May 14, 2004
Configure
Process Inputs Inputs configured as temperature type and assigned to meter runs
2-4 temperatures or meter runs 2-4 density temperature were not
reading/writing to the correct register numbers. This caused
the temperature type codes to be corrupted.
Changes in fields gave Modbus ID range error. Modbus ID should
only be checked for SV/Rosemount DP input types.
Ethernet Setup - Modbus ID had incorrect register.
Diagnostics
WinPanel - Key presses typed fast at the PC keypad were interpreted at
the OMNI as lower case.
Communications
Set the default direct default intercharacter time out to be 100ms and
modem intercharacter time out to be 150.
*******************************************************************************
Version 1.05 - May 13, 2004
Configure
Digital I/O page now has type selection.
Fluid Products for 27.74.11 and up
AGA-10 added.
ISO5167 Version 2003(E) selection added.
Orifice and V-Cone Meters - App 27 - changed "Disable Isentropic
Temperature" label to "Use Upstream Temperature".
V-Cone Meters - App 27 - Physical Meter Run - removed ISO5167 selection
as does not apply.

File Revisions now show in latest to oldest order.


Tab and enter keys didn't work inside pages. Introduced when Security
added in v1.04.
Communications
Corrected invalid CRC messages.
Original data wasn't being restored if data not sync'd when go
offline if there was no file associated with the document.
Help file
Updated for Digital I/O assignments.
*******************************************************************************
Version 1.04 - April 28, 2004
Configure
File Revision screen added when opening new files.
Last application, version, and revision used updated on file open.
Revision only shows on caption bar with versions 74 and up.
Allows for version 74 with revisions less than 10.
Process Inputs - SV cards - don't allow unassigned type.
Daniel, FMC, Instromet - AGA 10 VOS added.
Fluid Products - Setup - if density method AGA 8 1994 selected
AGA 10 calculation select added.
Phyical Meter Orifice - ISO5167 version had incorrect register number
and was giving Exception code 04 on writes. Was not applying
changes properly.
Product Setup - App 21 - crashed when reading registers for meter facto
r
decimal places because they do not exist.
Security added. Use when online in Configuration or Report Template Editor.
New default templates were added to the installation.
Updated help file.
Can only run one instance of the program. Settings file getting
overrwritten by last instance to close.
*******************************************************************************
Version 1.03 - April 16, 2004
Configure
Meter Run tree changed for orifice applications. There is a
separate "Configuration" entry that brings up the Meter Type page.
The Meter Setup page is now on the "Flowmeter" tree entry.
If there are any meter specific pages they go with "Flowmeter".
For Orifice, Instromet, and V-Cone there is a new "Physical Meter
Run" tree entry to set up the physical characteristics.
Meter specific screens have all been re-worked to fill in missing
fields and database entries.
Orifice and V-Cone meter types have a new DP Setup page under
"Flowmeter".
Omni I/O - Process Input tree changes:
HV - the "Process Inputs" tree entry has been replaced by
"MV-1" through "MV-4" tree entries. The DP, T, and P process
inputs are grouped according to each MV set.
SV - there is a new SV Setup page for each SV module.
The "Process Inputs" tree entry has been replaced by
"MV-1" through "MV-4" tree entries. The DP, T, and P process
inputs are grouped according to each MV set. The MV tree
entries are only shown if a Rosemount 3095FB meter type is
selected in the SV Setup page.
Process Inputs:
Removed alarm limits for flowmeters and moved to Meter Setup.
Inputs configured as an Aux Input type were not reading/writing
to the correct register numbers. This caused limits, input
scaling, overide value, and damping codes to be corrupted.
Factors and System Contants

Added Molecular Weight for gas apps.


Ft3 to Gallons - increased significant figures to 7.
General
Files - incorrect extension on file save when closing down frame or
closing all frames using the X in the top right hand corner.
If you opened a file, connected to a unit and then saved the file, the
first PI tag was corrupted.
Before transmit when checking file verses unit, only check and show
the maximum number of ports (file or unit).
*******************************************************************************
Version 1.02 - April 1, 2004
Configuration
General Setup:
Equipment List Added 2nd GC checkbox
Flags are auto checked if valid I/O exists even for v74 and up
enable prove flag added for gas apps
Active Options - tab removed
Factors and Constants - added nuisance alarm timer
Ports - Serial Port 3 - Hardware Setup - removed Modbus ID entry if
protocol type is GC.
Gas Chromatograph
GC Setup - 2nd GC added, Fail to 2nd GC fail code added
GC Components - C6 Distribution Percent added.
Operate
Archives - date browse function added.
Omni Flow Computers standard heading applied to Configuration files.
*******************************************************************************
Version 1.01 - March 18, 2004
Initial release