Anda di halaman 1dari 32

www.eaton.

com

Photovoltaic
for commercial application

Aerospace

Powering business
worldwide

Truck

Aerospace
A leading global supplier to
commercial and military aviation and
aerospace industries. An extensive
technology portfolio includes hydraulic
systems, fuel systems, motion control
systems, propulsion sub-systems,
cockpit controls and displays and fluid
health monitoring systems. Our
products improve fuel economy,
aircraft performance, reliability and
safety.

Discover Eaton a leader in the power management field


Truck

Since 1911, when our company began trading as a small truck parts supplier,
Eaton Corporation has come a long way. Today, as a diversified power
management company, Eaton has sales of $13.7 billion USD (FY 2010),
employs 70,000 people and has customers in more than 150 countries.
Everyday, we help companies across the world to manage power, and do
more, while consuming less energy.

Eatons innovative products, solutions and technologies are designed


to help customers
manage power and conserve
resources while working more
productively, safely and sustainably.
Our integrated and diversified
business strategy ensures that
we remain at the forefront of our
industry, decade after decade.

A leader in the design, manufacturing


and marketing of complete line of
drivetrain systems and components
for medium- and heavy-duty
commercial vehicles. Under the
Roadranger brand, Eaton also
markets lubricants, safety products
and service tools. Eatons hybrid
power systems have earned the
company recognition as a global
leader in alternative power for
commercial vehicles.
Electrical
A global leader in electrical control,
power distribution, uninterruptible
power supply and industrial
automation products and services.
Our products provide customer-driven
PowerChain Management solutions
to serve the power system needs of
the industrial, institutional,
government, utility, commercial,
residential, IT, mission critical and
OEM markets worldwide.

Electrical

Automotive

Powering business
more sustainably
Sustainability smaller footprint in the world
The principle of sustainability means meeting the current needs of our own
society without compromising the needs or options of future generations. It is
a principle, which forms the very core of our design and production philosophy
and guides all our activities across the world. Our commitment to reducing our
own ecological footprint covers a wide range of green technologies, products
and services that help our customers utilise electrical power more efficiently,
while improving environmental performance.

Hydraulics

Automotive
A supplier of critical components
that reduce emissions and fuel
consumption and improve stability and
performance of cars, light trucks and
commercial vehicles. Principal
products include engine valves and
valve train components, transmission
and engine controls, supercharger,
locking and limited slip differentials,
cylinder heads, fluid conveyance
components, body mouldings and
spoilers.
Hydraulics
A worldwide leader in reliable,
high-efficiency hydraulic systems and
components for use in mobile and
industrial applications. Markets include
agriculture, construction, mining, forestry, utility, material handling, earth
moving, truck and bus, machine tools,
moulding, primary metals, automotive,
power generation, port machinery and
entertainment.

Eaton is known around the world


for its uncompromising approach
to ethical business practices and
every year since 2007 they have
been ranked by the Ethisphere
Institute as one of the worlds
most ethical companies.

Learn more about Eaton Green Solutions at


www.eaton.com/greensolutions
When you see this symbol, you know the
solution represents an Eaton bench-mark
for environmental performance.

An important step towards a reliable energy supply in the future


The sun provides life on
our planet. As a source of
energy, it holds unimaginable potential for supplying
energy in the future.
In view of the worlds
climate and energy goals,
as well as the catastrophic
events surrounding nuclear
power plants, solar power
is increasingly gaining
importance. The industry is
now experiencing increased
demand for industrial-sized
plants, such as solar roof
systems atop commercial
buildings, following enormous
interest in the residential
construction sector.
Did you know
... that such a system with an
output of 7.4 MW would
be capable of generating
approx. 7.3 million kWh of
energy every year, which
would correspond to the
annual requirements of
approx. 1,800 homes?
... that the worlds largest
photovoltaic system has
an output of 80 MW? It
is located in Sarnia, near
Ontario (Canada).
... that since the end of March
2011, more solar capacity
than nuclear-power- plant
output is found in the
power grid in Germany?
Photovoltaic systems with
a total nominal power of
approx. 17 gigawatts are
now outperforming nuclear
power plants with a total
of approx. 15 gigawatts
for the first time, since
the oldest German atomic
4

power plant was shut


down.
... that renewable energies
would not make electricity
more expensive, but rather
have a restraining effect on
prices?
... that the photovoltaic capacity installed worldwide
totals approx. 40 gigawatts
to date, and that approx.
16 gigawatts are added
every year?
In the meantime, the
renewable energy industry
has become an astounding
economic factor, revitalising
the employment market and
creating numerous green
jobs.
The choice of the right components for a PV system is of
fundamental importance. The
system will be in operation
for many years and all parts of
the system must satisfy the
highest standards. The appropriate quality and longevity,
as well as warranties and Service support are necessary in
order to guarantee long-term
success.
Here you can see the
industrial-size systems that
Eaton offers.

Leading the way


with safety
Eaton ensures the
reliable availability
of renewable
energies safe for
people and good for
the environment.

From solar module to


power grid
Solar power is becoming
increasingly more important
and safety plays a decisive
role. From the outset, it
pays to invest in the right
technology. Eaton delivers
all products needed to safely
transport energy from solar
panels to the power grid.
Reliable protection, separation
and control technology
provide for the safe operation
of photovoltaic systems,
using integrated or external
separation equipment for
automated and manual operation and for both direct and
alternate currents (DC/AC).

Safety from the startt


esign
Proper planning and design
are crucial to the safe and
reliable operation of a
photovoltaic plant, and
d ensure
trouble-free operation of all
switching, contacting, protection, separation, insulation
ation
and monitoring functions.
Through intensive cooperation
with system integrators,
manufacturers and switch
gear plant builders, Eaton
offers full peace of mind, right
from the start.

player and partner, Eaton


stands for high product
availability, outstanding quality
and exceptional service for
individual solutions.
It is this high level of
innovation combined with
environmentally proven
technology, that has
characterized the quality and
daily operational use of
Eaton products in the field
for many years.

As one of the leading


global energy management
companies, Eaton guarantees
know-how, proximity and
the dynamics you need to
successfully complete your
project. Moreover, as a global

Renewable energy is a part of the markets of the future.


Having Eaton as an experienced, reliable partner is a good thing:
High-quality circuit breaker series, especially for photovoltaic use
Reliable and fail-safe
Eaton has been a global player and reliable partner for more than
100 years, with decades-long experience in energy distribution

DC components

Quality and safety for the entire DC current requirements: Eaton DC components.

String circuit-breakers
PKZ-SOL

DC switch disconnectors

DC overvoltage protection

CI insulated enclosures

Switch-disconnectors NDC
in the special version for up
to 1500 V DC can be used on
1 or 2-poles. They comply
with the isolation properties
even for earthed IT networks.
Accessories, such as Bridge
kits, connection terminals and
door coupling rotary handles,
enable individual installation
in the most varied of distribution systems. Auxiliary
switches, voltage releases
and remote operators facilitate
signalling and automation.

The surge arrester SPPT2PA


has been developed especially for photovoltaic applications
and protects the installations
against transient overvoltages
that can be induced by indirect lightning strikes. Eaton
provides versions for both
earthed and unearthed installations, where spark gaps are
used to ensure galvanic isolation. Naturally, the units are
available as prewired ready-touse modules just install and
they are ready to go.

The weather-proof CI enclosures with the enhanced degree


of protection IP 65
are ideal for outdoor installation. Thus, you can safely and
cost-effectively protect and
install your switchgear. The
modular design simplifies the
adaptation to different application areas, such as generator connection enclosures for
direct protection of several
strings in a field.

The fuseless alternative for


protection against short circuit
currents with the string circuitbreaker PKZ-SOL. With their
variable trip range, they can
be optimally adjusted to the
actual short-circuit current of
a string. A thermal release
reacts at 1.05 1.3 fold
current, and the magnetic
release at 6-fold current.
Non-enclosed string circuitbreakers are intended for
installation in customized
generator connection
enclosures.

Power grid coupled photovoltaic systems feed the generated power directly into the electrical
grid without complex and costly intermediate storage. An installation of this kind mainly consists on the DC end of solar modules, cables and different switchgear for operation, maintenance and protection in the event of a fault. Eaton provides you with a complete product range
for protection, switching and isolation to safely and efficiently transport the solar energy from
the individual solar modules to the power inverter.

AC components

Quality and safety on the AC current level: Eaton AC components.

Contactors DIL

Circuit-breakers
NZM and IZM

Control and
monitoring

Medium-voltage systems
XIRIA

The circuit-breaker series


NZM offers optimum installation protection up to 1600 A
with four sizes. The air circuitbreaker IZM, also with four
sizes, covers the power range
up to 6300 A. Both series are
characterised by their high
switching capacities and
comprehensive range of
accessories and provide a
solution for every application.
Eight sizes allow you to
cost-effectively engineer the
required dimensions and
ratings of the switch.

Eaton panels are operating


and monitoring devices that
also can be used as control
devices. Modern touch
panels cater for clear, flexible
menu-guidance in every
desired language and allow
worldwide application
with just one hardware and
software solution. The optimum solution is available for
every application with touch
panels from 3.5 to 19.

XIRIA ring main units protect


applications up to 24 kV. They
operate with a combination
comprised of circuit-breakers
and electronic relays and
feature high level of operational safety and a compact
design. They are available in
three or four panel versions.

The contactors DIL H safely


switch the power inverters
onto the grid. The innovative
construction design using
vacuum tubes reduces the
holding power by up to 96 %.
Accordingly, not only is the
heat development in the
control panel reduced, but
also the day-to-day operating
costs. Seven sizes cover the
power range up to 2600 A.
Eaton also offers 4-pole
contactors up to 800 A.

Eaton also supplies everything on the AC level that you require for the safety and efficiency
of your photovoltaic installation. From the power inverter right up to the power grid, Eaton
components guarantee the best possible installation safety and assure reliable operation and
optimum power feed.

In the eld of renewable forms of energy, panel builders


put their trust in Eatons xEnergy switchgear system:

5 variants, X with maXimum benets

XP Power Sections

XF Fixed

XG General

Incoming supplies, outgoers and couplings


with circuit breakers
Internal separation up to form 4
Cable connection from the top or bottom
Incoming supply system for drill-free
cable connection

Power outgoers with circuit breakers and


fuse switch disconnectors up to 630 A
Internal separation up to form 4
Individual outgoers, such as controlgear,
motor starters, small power outgoers etc.

Power factor corrections


Fitting systems for sub-distribution
with devices for modular installation
Control technology with SASY 60i
and xStart
Individual fixed units on a mounting
plate

XR Removable

XW Withdrawable

Power outgoers with circuit breakers and


strip type switch-disconnector-fuse, up to
630 A
Empty modules for individual applications
Plug-in modules and strip type switchdisconnector-fuse can be replaced under
live-line working conditions
Internal separation up to form 4
Easy maintenance and reduced down times

Power outgoers with circuit breakers up to 630 A


Outgoers for motor starters up to 250 KW
Empty drawers for individual applications
Easy and uniform handling for all drawer sizes
Drawers can be replaced under live-line working conditions
Internal separation up to form 4
Unambiguous position indicator for operating,
test or de-energized status
Easy maintenance without the need of using any special tools
for replacement jobs
Minimum down times

Content
DC-Disconnectors to 1500 V
Selection Information
Page 10
Technical Data
Page 12

DC-Disconnectors
Selection Information
Technical Data

Page 15
Page 17

Surge Protection
Selection Information
Technical Data

Page 21
Page 22

CS Wall-Mounted Sheet Steel


Selection Information
Page 24
Technical Data
Page 25

CI insulated enclosures
Selection Information
Page 27
Technical Data
Page 28

Contactors DILM
Selection Information
Technical Data

Page 30
Page 31

Photovoltaic - Switch-disconnectors
Switch-disconnectors for 1000/1250/1500 V DC, 2 pole

wa_sg05309

IEC/EN 60947-3
Main switch characteristics including positive drive to IEC/EN 60204 and VDE 0113
Isolating characteristics to IEC/EN 60947 and VDE 0660
Busbar tag shroud to VDE0160Part100
Switch-disconnectors N can, in addition, be combined with voltage releases NZM...-XU, NZM...-XA
and auxiliary contacts as well as with remote operator NZM...-XR...
For 2 pole switching, series connection of two poles each is required. See accessories bridge kits
N2..: Can not be combined with early-make auxiliary contacts NZM-..XHIV or box terminal NZM2-4-XKC
at Ui > 1000 V DC
For non-earthed networks > 1000 V DC the installation must be configured such that the likelihood of
a double earth fault is negligibly small
Switches can not be combined with withdrawable units and/or connection on rear

Rated operational
current rated =
uninterrupted
current
In = Iu
A

Short-circuit
protective
device max.
fuse gRcharacteristic
A gR

Screw
connection

Fixed mounted
Designation
Article No.

Units per package

160

200

1 pcs.

200

200

250*

315

N2-4-160-S1-DC
127732
N2-4-200-S1-DC
127733
N2-4-250-S1-DC*
154940

N3-4-320-S1-DC
127734
N3-4-400-S1-DC
142267
N3-4-500-S1-DC
142268

1 pcs.

N4-4-800-S1-DC
119890
N4-4-1000-S1-DC
119891
N4-4-1250-S1-DC
119886
N4-4-1400-S1-DC
119887
N4-4-1600-S1-DC
152552

1 pcs.

1 pcs.
1 pcs.

*Estimated delivery date as of Jan. 2012

N3_3

320

500

400

500

500

500

800

1000

1250

1400

1600

1 pcs.
1 pcs.

wa_sg04609

10

1 pcs.
1 pcs.
1 pcs.
1 pcs.

Photovoltaic - Switch-disconnectors
Bridge kits NZM...-XKV

Model contains parts for upper switch side for 4 pole switches N...-S1-DC that are used as 2 pole switches for DC.
The links each connect two contacts in series
Incoming unit and outgoer at bottom or top, user-definable
N4-4-... > 1250 A: alternate connection at bottom through module plates NZM4-4-XKM2S-1600

Description

Rated operational current


In
A

For use with

No. Protecof tion

Designation
Article No.

Units per
package

Jumper kit
with cover

160 at 700C
200 at 650C

N2-4-...S1-DC

IP2X

NZM2-4-XKV2P
131730

1 pcs.

Jumber kit
with cover

400 at 700C

N3-320(400)-S1-DC 2

IP2X

NZM3-4-XKV2P
131731

1 pcs.

Jumper kit with


400 at 700C
insulating plates
500 at 500C
and phase isolator

N3-400(500)-S1-DC 2

IP00

NZM3-4-XKVI2P
142269

1 pcs.

Jumper kit
with cover
and heat sinks

400 at 700C
500 at 550C
500 at 400C

N3-400(500)-S1-DC 2

IP1X

NZM3-4-XKV2P-K
142271

1 pcs.

Jumper kit with


insulating plates,
phase isolator
and heat sinks

500 at 650C

N3-500-S1-DC

IP00

NZM3-4-XKVI2P-K
142270

1 pcs.

Jumper kit
with cover

1250 at 650C N4-4-800-...S1-DC 2


1400 at 400C N4-4-1000-...S1-DC
N4-4-1250-...S1-DC
N4-4-1400-...S1-DC

IP2X

NZM4-4-XKV2P
119888

1 pcs.

Jumper kit with


phase isolator
and heat sinks

1400 at 650C N4-4-1400-S1-DC


1500 at 650C N4-4-1600-S1-DC
1600 at 400C

IP00

NZM4-4-XKV2P-K
152553

1 pcs.

poles class

IP2X

11

Photovoltaic - Switch-disconnectors
Technical data
Switch-disconnectors 1000/1250/1500 V DC

N2-4..S1-DC
max. 200 A

N3-4..S1-DC
max. 500 A

N4-4..S1-DC
max. 1600 A

Rated operational voltage


Ue
VDC
1000 (1250*)
Rated uninterrupted current with terminal jumpers
Iu
A
200 (250*)
at 400C
Iu
A
200 (250*)
at 650C
Rated operating current
Ie
200 (DC-22A)
Rated short-time withstand current t = 0,1 s
Icw
kA
3
kA
t=1s
Icw
Rated conditional short-circuit current
Iq
kA
15
With back-up fuse up to 1000 V
A gR
200 (315*)
Maximum operating frequency
Ops/h
120
Lifespan
mechanical (of which max. 50 %
Operations
20000
trip by shunt/undervoltage release)
electrical
Operations
2500 (DC 22-A)
Rated insulation voltage
Ui
V DC
1250
For use in IT electrical power networks
V DC
1000
Notes:
N...S1-DC can not be combined with withdrawable units and/or connection on rear.
N2...: Can not be combined with early-make auxiliary contacts NZM-...XHIV
or box terminal
For 2 pole switches series connection of two poles each is required.

1250 (1500**)

1500

500
500
500 (DC-22A)
6
6
15
500
60

1600
1500
1500 (DC-22A)
25
25
20

15000

10000

2000 (DC 22-A)


1250 (1500**)
1000

500 (DC 22-A)


1500
1000

Estimated delivery date as of


Jan. 2012
** Estimated delivery date as of
July 2011

Temperature dependency
Basic devices

Bridge kits

Reduction of the rated operational current (derating) under particular ambient conditions
Busbar MountTemperature compensation coefficient
tag
ing
20 C
30 C
40 C
50 C
55 C
60 C
65 C
70 C
shroud position

Switch-disconnector
N2-4-160-S1-DC

+NZM2-4-XKV2P

IP2X

v
h

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

N2-4-200-S1-DC

+NZM2-4-XKV2P

IP2X

v
h

1
1

1
1

1
1

1
1

1
1

1
1

1
0,95

0,95
0,92

N3-4-320(400)-S1-DC

+NZM3-4-XKV2P

IP2X

v
h

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

+NZM3-4-XKVI2P

IP00

v
h

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

+NZM3-4-XKV2P-K

IP2X

v
h

1
1

1
1

1
0,98

0,95
0,93

0,92
0,9

0,89
0,87

0,86
0,84

0,83
0,81

+NZM3-4-XKV2P-K

IP1X

v
h

1
1

1
1

1
1

1
1

1
0,97

0,98
0,94

0,95
0,91

0,92
0,89

+NZM3-4-XKVI2P

IP00

v
h

1
1

1
1

1
1

1
0,97

0,97
0,95

0,95
0,92

0,92
0,89

0,89
0,87

+NZM3-4-XKVI2P-K

IP00

v
h

1
1

1
1

1
1

1
1

1
1

1
1

1
0,97

0,97
0,95

N4-4-800(1000)-S1-DC

+NZM4-4-XKV2P

IP2X

v
h

1
1

1
1

1
1

1
1

1
1

1
1

1
1

1
1

N4-4-1250-S1-DC

+NZM4-4-XKV2P

IP2X

v
h

1
1

1
1

1
1

1
1

1
1

1
1

1
0,97

0,97
0,95

N4-4-1400-S1-DC

+NZM4-4-XKV2P

IP2X

v
h

1
1

1
1

0,97

0,94
0,91

0,92

0,9

N3-4-500-S1-DC

N4-4-1600-S1-DC

+NZM4-4-XKV2P-K

IP00

v
h

1
1

1
1

1
1

1
1

11)
11)

11)
11)

11)
11)

0,97
0,97

+NZM4-4-XKV2P-K

IP00

v
h

1
1

1
1

1
1

0,98
0,98

0,961)
0,961)

0,941)
0,941)

0,931)
0,931)

0,911)
0,911)

Notes: Mounting position: v = vertical, h = horizontal


Incoming unit and outgoer at bottom or top, user-definable.
12

1)

Incoming unit from bottom only.

Photovoltaic - Switch-disconnectors
Dimensions
Switch-disconnectors, 4 pole, N2-4

Dimensions (mm)

Jumper kit, NZM2-4-XKVP

Blow out area, minimum clearance to other parts


Minimum clearance to adjacent parts

Switch-disconnectors, 4 pole, N3-4

Blow out area, minimum clearance to other parts


Minimum clearance to adjacent parts

Jumper kit, NZM3-4-XKV2P...

Jumper kit, NZM3-4-XKVI2P...

13

Photovoltaic - Switch-disconnectors
Dimensions

Dimensions (mm)

Switch-disconnectors, 4-polig, N4-4


Blow out area, minimum clearance to other parts
< 690 V: 100mm
< 1500 V: 200mm
Minimum clearance to adjacent parts
< 1000 V: 15mm
< 1500 V: 70mm

Jumper kit, NZM4-4-XKV2P

14

Jumper kit, NZM4-4-XKV2P-K

Photovoltaic - DC Disconnection

DC

DC switch-disconnector
DC switch-disconnector P-SOL 2-poles
Rated operational voltage 1000 VDC
Utilization category DC-21A
Rated op. current Ie

Type designation

Article No.

Units per package

20A
30A
63A

P-SOL20
P-SOL30
P-SOL60

120934
120935
120936

1
1
1

wa_sg05409, wa_sg04709

Connection diagrams:
PV array
Unearthed system

Earthed system

PV inverter

DC switch-disconnector
DC switch-disconnector SOL 2-poles as pre-wired unit with protection
class II, degree of protection IP65

Rated operational voltage 1000 VDC


Utilization category DC-21A
Rated operational current Ie of 20, 30 or 63 A
Several versions plugs MC4 or cable glands available
Versions for 2, 3 and 4 strings (INPUT) available

Ie

INPUT

OUTPUT

Type designation

Article No.

Units per package

1xMC4
1xMC4
1xMC4
1xMC4

SOL20/2MC4
SOL20/4MC4
SOL30/2MC4
SOL30/4MC4

120915
120916
120922
120923

1
1
1
1

120919
120926

1
1

wa_sg00110

MC4 version
20A
20A
30A
30A

2xMC4
4xMC4
2xMC4
4xMC4

Version with metric cable glands


20A
30A

2xM12
2xM12

1xM16
1xM16

SOL20/2MV
SOL30/2MV
SOL20/2MC4
SOL30/2MC4
SOL20/2MV
SOL30/2MV

SOL20/4MC4
SOL30/4MC4

15

Photovoltaic - DC String Protection

DC

DC string circuit-breaker
DC string circuit-breaker PKZ-SOL 2-poles
Rated operational voltage 900 VDC
Rated current In 4, 7, 12, 20, and 30 A
For permissible string short-circuit currents Isc of 5 up to 22 A
Ie

Isc

Type designation

Article No.

Units per package

4A
7A
12A
20A
30A

1,6-3A
2,6-5A
5-9A
9-15A
15-22A

PKZ-SOL4
PKZ-SOL7
PKZ-SOL12
PKZ-SOL20
PKZ-SOL30

144069
144120
120937
120938
120939

1
1
1
1
1

wa_sg05409

Connection diagrams:
PV string
Unearthed system

Earthed system

DC disconnection / PV inverter

16

Photovoltaic - DC String Protection

DC

DC Switch-disconnector P-SOL
Field of application:
DC-Disconnection in photovoltaic systems between
PV Array and Inverter to switch off the energy
No polarity
Any mounting position
Spring work contacts
Tested according to IEC/EN 60947-3, UL508
Certificate TV-Rheinland
Application acc. to IEC 60364-7-712 and IEC 62548

Connection diagram
Unearthed system

Earthed system

Technical Data
P-SOL20

P-SOL30

P-SOL60

2
1000 VDC
20 A
500 A
700 A
DC-21 A
III
8 kV
1500
6m

2
1000 VDC
30 A
500 A
700 A
DC-21 A
III
8 kV
1500
5m

2
1000 VDC
63 A
1500 A
1500 A
DC-21 A
III
8 kV
1500
3m

58
93
76
265 g
35 mm

58
93
76
265 g
35 mm

IP20
2x (1-6)
18-10
1,7 Nm
-25C to +60C
Damp heat, constant
Damp heat, cyclic
2
100.000
<120

IP20
2x (1-6)
18-10
1,7 Nm
-25C to +60C

55
140
160
920 g
35 mm
2xM4x18
IP20
2x (1-35)
14-2
3 Nm
-25C to +60C

2
100.000
<120

100.000
<120

Electrical
Number of poles
Rated operational voltage Ue
Rated operational current Ie
Rated short-circuit making capacity Icm
Rated short-time withstand current 1sec. Icw
Utilization category
Overvoltage category
Rated impulse withstand voltage Uimp
Operating cycles electrical at Ue and Ie
Internal resistance
Mechanical
Width
Height
Depth
Weight
Mounting quick fastening on DIN rail acc. to IEC/EN 60517
Screw fastening
Degree of protection
Terminal capacity Flexible with end sleeve
mm
AWG
Tightening torque of terminal screws
Ambient temperature range
Climatic resistance acc. to IEC 60068-2-78
acc. to IEC 60068-2-30
Pollution degree2
Operating cycles mechanical
Operating cycles mechanical per hour

Dimensions (mm)
P-SOL20
P-SOL30

P-SOL60

17

Photovoltaic - DC String Protection

DC

DC Switch-disconnector SOL as pre-wired unit


Field of application:
DC-Disconnection in photovoltaic systems between
PV Array and Inverter to switch off the energy
Pre-wired unit ready for connection
Lock-able in OFF-position with a padlock
Any mounting position
Spring work contacts
Tested according to IEC/EN 60947-3, UL508
Certificate TV-Rheinland

Connection diagram
Unearthed system

Earthed system

Technical Data
SOL20

SOL30

2
1000 VDC
20 A
500 A
700 A
DC-21 A
III
8 kV
1500
8m

2
1000 VDC
30 A
500 A
700 A
DC-21 A
III
8 kV
1500
5m

420 g
IP65
-25C to +60C
Damp heat, constant
Damp heat, cyclic
3
100.000
<120

420 g
IP65
-25C to +60C

Electrical
Number of poles
Rated operational voltage Ue
Rated operational current Ie
Rated short-circuit making capacity Icm
Rated short-time withstand current 1sec. Icw
Utilization category
Overvoltage category
Rated impulse withstand voltage Uimp
Operating cycles electrical at Ue and Ie
Internal resistance
Mechanical
Weight
Degree of protection
Ambient temperature range
Climatic resistance acc. to 60068-2-78
acc. to 60068-2-30
Pollution degree
Operating cycles mechanical
Operating cycles mechanical per hour

3
100.000
<120

Dimensions (mm)
SOL20(30)

a
[mm]

MC4

234

MV

224

SOL20/2MC4
SOL30/2MC4

SOL20
SOL30

Input
+ Strings

- Strings

SOL20/2MV
SOL30/2MV

Input (M12)
+ Strings

- Strings

SOL20/4MC4
SOL30/4MC4

Input
+ Strings

Output (M16)
-

+
Output

18

- Strings

Photovoltaic - DC String Protection

DC

DC-String Circuit Breaker PKZ-SOL


Field of application:
DC-Circuit breaker for string protection
in photovoltaic systems
No polarity
Spring work contacts
Tested according to IEC/EN 60947-2
Certificate TV-Rheinland

Connection diagram
Unearthed system

Earthed system

Technical Data
PKZ-SOL4
PKZ-SOL7
PKZ-SOL12
PKZ-SOL20
PKZ-SOL30
Electrical
Number of poles
Rated operational voltage Ue
Rated current In
Thermal tripping characteristic
Electromagnetc tripping characteristic
Rated ultimate short-circuit breaking capacity Icu
Rated service short-circuit breaking capacity Ics
Overvoltage category
Rated impulse withstand voltage Uimp
Operating cycles electrical at Ue and In
Internal resistance

2
900 VDC
4 / 7 / 12 / 20 / 30 A
1.05 to 1.3 x In
6 x In
5 kA
1.5 kA
III
8 kV
1500
138 / 60 / 32 / 14 / 9 m

Mechanical
Width
Height
Depth
Weight
Mounting quick fastening on DIN rail acc. to IEC/EN 60517
Screw fastening
Degree of protection
Terminal capacity Flexible with end sleeve mm
AWG
Tightening torque of terminal screws
Ambient temperature range
Climatic resistance acc. to IEC 60068-2-78
acc. to IEC 60068-2-30
Pollution degree
Operating cycles mechanical
Operating cycles mechanical per hour

58
93
76
265 g
35 mm
IP20
2x (1-6)
18-10
1,7 Nm
-25C to +60C
Damp heat, constant
Damp heat, cyclic
2
100.000
<120

Mounting position
PKZ-SOL4
PKZ-SOL7
PKZ-SOL12
PKZ-SOL20
PKZ-SOL30

90

90

90

19

Photovoltaic - DC String Protection

DC

DC-String Circuit Breaker PKZ-SOL


Characteristic curve setting value - Short-circuit current
According to the design for IEC 62548-1, the tripping current for the circuit breaker must fall within a range of 1.4 to 2 times the value of the short-circuit current of the PV modules, in order to protect the PV modules.
Since only the current values for the built-in overload tripping device can be plotted on the setting scale of the circuit breaker1), the correlation between the
tripping current for the safety device and the short-circuit current for the PV modules must be properly indicated for every point of the scale.

Adjustment tool for string circuit breaker PKZ-SOL


35

30

SettingEinstellwert
value at the
circuit breaker
am Schutzschalter
[A][A]

tripping time

Tripping characteristic curve


String circuit breaker PKZ-SOL

PKZ-SOL30
25

20
PKZ-SOL20
15

PKZ-SOL12

10

PKZ-SOL7

PKZ-SOL4
0
0

10

15

20

25

Kurzschlussstrom
[A] [A]
Short-circuit
currentSolarmodul
solar module

1)

Norm IEC/EN 60947-2 (section 4.7.3) prohibits a direct specification


of the PV short-circuit current on the circuit breaker's setting scale,
whereby only the setting value for the response current may be
entered.

Dimensions (mm)
PKZ-SOL4
PKZ-SOL7
PKZ-SOL12
PKZ-SOL20
PKZ-SOL30

20

Photovoltaic - Surge Protection

AC

SPD-type T2 (Class C)
sg13309

Max. Cont. Op. Volt. UC In (8/20)s

Type Designation

Article No.

Units per package

131755
131756
131757
131758
131759
131760
131761
131762
131773
131774

12 / 120
1 / 60
1 / 40
1 / 30
12 / 120
1 / 60
1 / 40
1 / 30
1 / 60
1 / 30

SPMT2PA-280
SPMT2PA-335
SPMT2PA-NPE

131778
131779
131783

4 / 120
4 / 120
4 / 120

Type designation

Article No.

Units per package

ASAUXSC-SPM

131785

4 / 120

131784

12 / 120

Plug-in surge arrester SPMT2PA, 1- to 4-pole


1pole
2pole
3pole
4pole
1pole
2pole
3pole
4pole
1+1p
3+1p

SG13109

280VAC
280VAC
280VAC
280VAC
335VAC
335VAC
335VAC
335VAC

1x20kA
2x20kA
3x20kA
4x20kA
1x20kA
2x20kA
3x20kA
4x20kA

SPMT2PA-280/1
SPMT2PA-280/2
SPMT2PA-280/3
SPMT2PA-280/4
SPMT2PA-335/1
SPMT2PA-335/2
SPMT2PA-335/3
SPMT2PA-335/4
SPMT2PA-1+NPE
SPMT2PA-3+NPE

Inserts SPMT2PA for replacement


Insert 1-pole
Insert 280VAC
Insert 335VAC
Insert N-PE 260VAC

Description
SG12809

Auxiliary Switch
for SPMT2PA

SG12909

20kA
20kA
30kA

Lead-through terminal for SPMT2PA


ASLTT-63

21

Photovoltaic - Surge Protection

AC

SPD-Type T2 (Class C), Plug-In Surge Arresters SPMT2PA


Field of application:
For the protection of photovoltaic systems against transient overvoltage
caused by indirect lightning stroke and switching operations.
Test class II according to IEC 61643-1
SPD-type T2 according to EN 61643-11
Galvanic seperation in unearthed systems by means of a spark gap
Types SPPT2PA-...-AX for remote message transmission of defective inserts

Connection diagram

Technical Data
Inserts

SPMT2PA -280

-335

-NPE

T2

T2

Electrical
SPD-type
Mechanical coding
Responding time
Voltage protection level at nominal discharge current / Uoc
Voltage protection level at 5 kA (8/20) s
Maximum continuous operating voltage Uc
Temporary overvoltage test value UT
Rated frequency
Open circuit voltage Uoc
Nominal discharge current (8/20) s In
Charge Q at In
Specific energy at In
Maximum discharge current Imax
Follow current interrupt rating Ifi
100 Aeff
Permissible back-up fuse
Maximum short-circuit current

T2

T3

x
< 25 ns
< 1,4 kV
1000 V
280 VAC
350 VAC (5s)
50/60 Hz
10 kV
20 kA
0,57 As
5,7 kJ/
40 kA

T3

x
< 25 ns
< 1,6 kV
1200 V
335 VAC
415 VAC (5s)
50/60 Hz
10 kV
20 kA
0,57 As
5,7 kJ/
40 kA

160 AgL
50 kAeff

T3

y
< 100 ns
< 1,5 kV
260 VAC
12000 VAC (200ms)
50/60 Hz
5 kV
40 kA
1,14 As
22,8 kJ/
60 kA

mMCT-C100
20 kAeff

Connection diagram

Mechanical
Frame size
Device height
Device width
Weight Base 1P, 1+1P, 2P, 3P, 3+1P, 4P
Weight Complete Devices 1P, 1+1P, 2P, 3P, 3+1P, 4P
Permitted ambient temperature
Degree of protection (built-in)
Upper and lower lift terminal capacity
Upper and lower open mouthed terminals
for busbar thickness up to
Tightening torque of terminal screws
Quick fastening on DIN rail according to

Dimensions (mm)

1.5 mm
2.4 - 3 Nm
IEC/EN 60715

Application Examples SPMT2PA according to IEC 60364-5-53 Clause 534

SPMT2PA280/3

22

45 mm
80 mm
17,5 mm per pole
53/120/120/180/240/240 g
110/201/220/330/412/440 g
-40C to +70C
IP40
4 - 25 mm2

SPMT2PA-280/4

SPMT2PA-3+NPE

SPMT2PA1+NPE

ASLT
T-63

Photovoltaic - Surge Protection

AC

SPD-type 2 (Class C), Surge Arresters SPMT2PA-1+NPE, SPMT2PA-3+NPE


Field of application:
For the protection of low voltage distribution systems against transient
overvoltage caused by indirect lightning stroke and switching operations.
Test class II according to IEC 61643-1
SPD-type T2 according to EN 61643-11
Auxiliary switch ASAUXSC-SPM for remote message transmission can be
mounted onto the device
Suitable for busbar connection to EATON switchgear
Type SPMT2PA-3+NPE:
consists of 1 base,
1 insert SPMT2PA-NPE and 3 inserts SPMT2PA-335
Type SPMT2PA-1+NPE:
consists of 1 base,
1 insert SPMT2PA-NPE and 1 insert SPMT2PA-335

Technical Data
SPMT2PA-1+NPE

SPMT2PA-3+NPE

Electrical
SPD-type
Mechanical coding
Responding time
Maximum continuous operating voltage UC
Temporary overvoltage test value UT (5 s)
(200 ms)
Rated frequency
Nominal discharge current In
Voltage protection level Up at In
Maximum discharge current Imax
Follow current interrupt rating Ifi
Permissible back-up fuse
Maximum short-circuit current

T2

L-N/N-PE/L-PE
L-N/N-PE
L-N
N-PE
L-N/N-PE/L-PE
L-N/N-PE/L-PE
L-N/N-PE/L-PE
N-PE

T3

T2

yx
< 25ns/< 100ns/< 100ns
335VAC/260VAC
415 VAC
1200 VAC
50/60 Hz
20 kA (8/20)s
1600V/1500V/2050V
40 kA (8/20)s
100 Ar.m.s.

160 AgL
50 kAr.m.s.

T3

yxxx
< 25ns/< 100ns/< 100ns
335VAC/260VAC
415 VAC
1200 VAC
50/60 Hz
20 kA (8/20)s
1600V/1500V/1900V
40 kA (8/20)s
100 Ar.m.s.

mMCT-C100
20 kAr.m.s.

Connection diagram

L1

L2

L3

Mechanical
Mechanical coding of base
Frame size
Device height
Device width
Weight
Upper and lower lift terminal capacity
Open-mouthed terminals at both sides for busbar thickness up to
Tightening torque of terminal screws
Permitted ambient temperature
Mounting
Degree of protection (built-in)

yx
yxxx
45 mm
45 mm
80 mm
80 mm
35 mm
70 mm
201 g
412 g
1 - 25 mm2
1 - 25 mm2
1.5 mm
1.5 mm
2.4 - 3 Nm
2.4 - 3 Nm
-40C to +70C
-40C to +70C
quick fastening on DIN rail IEC/EN 60715
IP40
IP40

Dimensions (mm)

Application Examples

SPMT2PA-1+NPE

SPMT2PA-1+NPE

SPMT2PA-3+NPE

SPMT2PA-3+NPE

SPMT2PA-NPE

SPMT2PA-NPE

SPMT2PA-335

SPMT2PA-335

23

CS Wall-Mounted Sheet Steel Enclosures with Mounting Plate


CS Wall-Mounted Sheet Steel Enclosures with Mounting Plate, IP66
Dimensions (mm)
Height A Width B

Depth C

300
300
300
400
400
400
400
400
400
400
500
500
500
500
600
600
600
600
600
600

150
200
200
150
200
150
200
200
250
300
150
200
250
250
150
200
250
150
200
250

Designation

Article No.

Units per package

CS-33/150
CS-33/200
CS-34/200
CS-43/150
CS-43/200
CS-44/150
CS-44/200
CS-46/200
CS-46/250
CS-46/300
CS-54/150
CS-54/200
CS-54/250
CS-55/250
CS-64/150
CS-64/200
CS-64/250
CS-65/150
CS-65/200
CS-65/250

111648
111649
111680
111681
111682
111683
111684
111685
111686
111687
111688
111689
111690
111691
111692
111693
111694
111695
111696
111697

1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.
1 pcs.

Designation

Article No.

Units per package

133104

VT28910

VT21110

300
300
400
300
300
400
400
600
600
600
400
400
400
500
400
400
400
500
500
500

Universal Locks
Description
VT12010

Identical locking, lock cylinder LC-ZSBIT-CS


with 2 keys

Ease-of-use Rotary Handle


Description

Designation

Article No.

Units per package

Retro-fitting set

PHZ-A-ADD-ON

133106

VT12110

Profile Half-Cylinder for Ease-of-use Handles


Description

Designation

Article No.

Units per package

Identical locking
Different locking

PHZ-E10/30-GS
PHZ-E10/30-VS

138574
138575

1
1

VT33610

Material for Fixing on a Mast


Dimensions Enclosure Width (mm)

Designation

Article No.

Units per package

300
400
500
600
800

MAST-FIT-CS

140478

VT33510

For more products, please refer to our Industry main catalogue


24

Technical Specifications
Technical Data
General information
Standards and regulations
RoHS
Climatic resistance
Ambient temperature
Degree of protection
Degree of protection with ventilation panels
Set-up locations
Incorporation grid

mm

IEC/EN 60529, IEC 62262, IEC/EN 62208


According to Directive 2002/95/EG of the European Parliament and Council
Moist heat, constant according to IEC 60068-2-78,
Moist heat, periodic according to IEC 60068-2-30
-40 to +70
IP66
IP23
Indoor/outdoor
25

Dissipated power loss

See separate table

Material
Material
Surface finish
Colour
Surface
Degree of gloss
Body
Mounting plate
Door
Bottom panel

Sheet steel
Structured powder-coating on Polyester base
RAL 7035, light grey
Slightly structured
Glossy
CS-65/...: 1.2; CS-66/...: 1.5
2; as of height 800 x width 400mm: 3
CS-43/...: 1.0; CS-64/...: 1.2; CS-88/...: 1.5; CS-1212/...: 2.0
1.5

mm
mm
mm
mm

Material properties
Mechanical
Shock-resistance rating
Assembly weight - entire cabinet
Assembly weight - door
Assembly weight - mounting plate
Assembly weight - wall-mounting brackets

IK09 according to EN 62262


See separate table
See separate table
See separate table
See separate table

Description/Basic equipment
Type of construction
conductor
Rear panel
Side panels
Top panel
Bottom panel

Folded and seam-welded, 2 M6 threaded bolts are included for protective


connection inside the enclosure
9 mm holes for wall-fixing
No holes
No holes
No holes, foam sealant, removable for F3A-... flanges or for customized
solutions
Basic equipment, sheet steel, sendzimir zinc-plated. 15 mm clearance to rear
panel. Mounted onto M8 copper thread-welding bolt. Therefore an additio-

Mounting plate
nal
Door

Door hinges
Door opening angle
Locking system
Locks

Number

protective conductor connection is not compulsory.


1 M6 thread-welding bolt for protective conductor connections in the door.
Where electrical operating material needs to be integrated in the
door, a consistent and permanent protective conductor connection
needs to be established by means of a protective conductor cable.
Please use the thread-welding bolts on the door and on the side
panel of the body as connecting points.
Right side, can be reversed on-site
120
Metal turnbuckle. standard lock. 3 mm two-way key-bit.
See Ordering Section

Fixing on a mast
MAST-FIT-CS

25

Dimensions
Dimensions Enclosure

Type
CS-33/150
CS-33/200
CS-34/200
CS-43/150
CS-43/200
CS-44/150
CS-44/200
CS-46/200
CS-46/250
CS-46/300
CS-54/150
CS-54/200
CS-54/250
CS-55/250
CS-64/150
CS-64/200
CS-64/250
CS-65/150
CS-65/200
CS-65/250

a
300
300
300
400
400
400
400
400
400
400
500
500
500
500
600
600
600
600
600
600

Mounting Plates

b
300
300
400
300
300
400
400
600
600
600
400
400
400
500
400
400
400
500
500
500

Dimensions Doors

c
150
200
200
150
200
150
200
200
250
300
150
200
250
250
150
200
250
150
200
250

Type

MPP, MPL
CS-33/150
CS-33/200
CS-34/200
CS-43/150
CS-43/200
CS-44/150
CS-44/200
CS-46/200
CS-46/250
CS-46/300

t1
112
172
172
112
172
112
172
172
172
172
112
172
172
172
112
172
172
112
172
172

t2
232
262
332
232
262
332
332
532
532
532
332
332
332
432
332
332
332
332
432
432

t3
80
140
140
140
140
140
140
140
140
140
80
140
140
140
80
140
140
80
140
140

Mounting Plate
Height Width
270
250
270
250
270
350
370
250
370
250
370
350
370
350
370
550
370
550
370
550

a, b = Gehusemae

CS Wall-mounted Enclosure with door and blind flanges

26

Type

t4
200
230
300
200
230
300
300
500
500
500
300
300
300
400
300
300
300
300
400
400

Enclosure
Height Width
250
200
300
200
300
300
300
400
400
300
400
400
400
600
500
400
500
500
600
400
600
500

Mounting Plate
Height Width
CS-54/150 470
350
CS-54/200 470
350
CS-54/250 470
350
CS-55/250 470
450
CS-64/150 570
350
CS-64/200 570
350
CS-64/250 570
350
CS-65/150 570
450
CS-65/200 570
450
CS-65/250 570
450

Door
Height
248
298
298
298
398
398
398
498
498
598
598

Width
197,5
197,5
297,5
397,5
297,5
397,5
597,5
397,5
497,5
397,5
497,5

CI Insulated Enclosures
Basic enclosures, IP65 (Apertures and Bases)
Lockable enclosure covers without openings
Two or four lockable cover fasteners, diagonal with cylinder lock
Cylindrical locks, uniformly locking
Two diagonal lead-sealable cover locks. When also replacing all DV...-CI
with DVZ...-CI, the sealing function is not avaliable
Equipment supplied: gasket, key
Dimensions
Width
Height
mm
mm

Mounting
depth
mm

For use
with

Number
Cylindrical
locks

Designation
Article No.

Units per
package

D125-CI23-RAL7032-DVZ
138526
D150-CI23-RAL7032-DVZ
138527
D125-CI43-RAL7032-DVZ
138528
D150-CI43-RAL7032-DVZ
138529
D200-CI43-RAL7032-DVZ
138530
D125-CI44-RAL7032-DVZ
138531
D150-CI44-RAL7032-DVZ
138532
D200-CI44-RAL7032-DVZ
138533
D250-CI44-RAL7032-DVZ
138534
D200-CI45-RAL7032-DVZ
138535
D200-CI48-RAL7032-DVZ
138536
D250-CI48-RAL7032-DVZ
138537

Tansparent cover RAL7032


0423_00329185.eps

187,5

375

250

125

U-CI23... 2

250

150

U-CI23... 2

250

125

U-CI43... 2

150

U-CI43... 2

200

U-CI43... 2

125

U-CI44... 2

150

U-CI44... 2

200

U-CI44... 2

250

U-CI44... 2

500

200

U-CI45... 2

750

200

U-CI48... 4

750

250

U-CI48... 4

375

4
2
2
2
2
2
2
2
2
2
2

Individual Enclosures Bases X


Seitenwnde glatt, ohne Vorprgungen
Dimensions
Width
mm

187,5
375
375
375

Designation

Article No.

Units per package

U-CI23X
U-CI43X
U-CI44X
U-CI45X

057909
062655
067401
098470

1
1
1
1

Designation

Article No.

Units per package

U-CI48

083880

Height
mm

250
250
375
500

Distribution board enclosure - Bases


Sides closed, but with full area knockout
Open top and bottom
Dimensions
Width
mm

375

Height
mm

750

A wider range of different enclosure covers, locking mechanisms


for the covers and any accessories you may need are presented in
our Industry main catalogue.
27

CI Insulated Enclosures
Technical data
CI23...
General
Standards

Climatic proofing
Ambient temperature
Protection type
Radiated heat dissipation

Material properties
Material
Base
cover
Surface treatment
Color
Base
Cover
Material properties
Electrical
Creepage resistance to IEC 60112
Base
Cover
Surface treatment to IEC 60093
Dielectric strength to IEC 60243-1
Thermal
Continuous thermal stability
Housing
Enclosure bolt
Sealing
Mechanical
IK code to EN 50102
Load bearing capacity
Chemical resistance
Resistant
Partially resistant
Non-resistant
Atmospheric
Saline spray
UV resistance
Water absorption to DIN EN ISO 62
Flammability characteristics
Glow wire to VDE 0471 Part 2
UL
Base
Cover
Halogen free

28

CI43...

CI44...

CI45...

CI48...

IEC/EN 60529
EN 50262
DIN 43656
DIN 43660
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
-40 at +80
IP65
next page

Glass-fibre reinforced polycarbonate


Non-reinforced polycarbonate
Corrosion-resistant
RAL 7032, pebble grey
Transparent, opaque or RAL 7032, pebble grey

x 1013
kV/mm

KB160, KC175
KB100, KC200
>1
30

C
C
C

-40 120
85
80

kg/m2

Please enquire
5
10

20

30

40

Acids < 10 %, mineral oil, alcohol, petrol, grease, saline solution


Acids > 10 %
Alkalis, paraffin

IEC 60068-2-11
Beneath protective canopy
0.29

960
UL94V1
UL94V2
yes (lower section and cover)

CI Insulated Enclosures
Dimensions

Dimensions (mm)

Enclosures CI43...

25

25

27

162.5

177

92

375

92

92

27

t = 150/175 mm

t = 150/175/225 mm

84.5

272

114.5

302

147

Enclosures CI45...

500

475

302

272

375

350

25

25

Enclosures CI44...

177

27

27

350

92

187.5

147

225
250

177

147

250

225

25

25

Enclosures CI23...

27

25

92

350
t

375

27

25
350

92

375

27

272

272

302

302

92

t = 225 mm

92

27

t = 150/175/225/275 mm

375

750

725

92

27

302

272

25

Enclosures CI48...

272
302

t = 225/275 mm

27

25

92

350
375

29

Controlling & Switching


Contactors DILM
Basic devices up to 170 A
Conventional
thermal
current Ith = Ie
open
AC-1 at 60oC
Ith=Ie
A

Can be combined
with auxiliary
contact

AC operation
Designation
Article No.

DC operation
Designation
Article No.

20

DILM32-XHI...
DILA-XHI(V)..

DILM12-10(230V50HZ)
276830

DILM12-10(24VDC)
276845

40

DILM32-XHI...
DILA-XHI(V)..
DILM32-XHI11-S

DILM32-10(230V50HZ)
277260

DILM32-10(RDC24)
277274

80

DILM150-XHI(V)...
DILM1000XHI(V)..

DILM65(230V50HZ)
277894

DILM65(RDC24)
277908

160

DILM150-XHI(V)...
DILM1000XHI(V)..

DILM150(RAC240)
239588

DILM150(RDC24)
239591

0389_00178013_0

Contactors DILM, DILH


Comfort devices greater than 150 A
Conventional
thermal
current Ith = Ie
open
AC-1 at 60oC
Ith=Ie
A

Designation
Article No.

Article No.

315

DILM225A/22(RAC240)

139547

350

DILM300A/22(RA250)

139556

700

DILM500/22(RA250)

208213

1400

DILH1400/22(RAW250)

272441

0389_00178013_0

30

Controlling & Switching


Contactors DILM
IEC60947-4-1
Contacts according to EN50012

Technical data
DILM12

DILM32 DILM65 DILM150 DILM225 DILM300

DILM500 DILH1400

x106
x106

10
10

10
10

C
C
C

-25 - 60
-25 - 40
-40 - 80

VA
VA
W
W

24
3.4
4.5
4.5

General
Lifespan, mechanical
AC operated
DC operated
Ambient temperature
open
enclosed
storage
Magnet systems
Power consumption of the coil
in a cold state and 1.0 x Uc
50HZ
50Hz
DC operated
DC operated

Operations
Operations

Pick-up
Sealing
Pick-up
Sealing

10
10

10
10

10
10

7
7

5
5

-25 - 60 -25 - 60 -25 - 60


-25 - 40 -25 - 40 -25 - 40
-40 - 80 -40 - 80 -40 - 80

-25 - 60
-25 - 40
-40 - 80

-25 - 60
-25 - 40
-40 - 80

-25 - 60
-25 - 40
-40 - 80

-25 - 60
-25 - 40
-40 - 80

52
7.1
12
0.5

210
2.6
180
2.1

380
4.3
250
3.3

450
4.3
350
3.3

800
7.5
700
6.5

149
16
24
0.5

10
10

180
3.1
149
2.1

31

Energy from sun

Helios, the power of the sun,


drove his four-horse chariot across
the sky, from east to west, every day.
With his enormous power, he granted
warmth and light to ensure life on
Earth.

Energy from wind

Aiolos, the power of the wind,


determined the fate of seamen. In a
favorable mood, he sent a favorable
wind. But when angered, he would
blow ships in the wrong direction.
Aiolos also played and important role
in the journey of Odysseus.

Energy from water


Poseidon, the power of the sea,
known to seafarers in search of
a peaceful journey by ship. In an
agreeable mood, he left the
sea calm. But when Poseidon grew
angry, he would strike the water
with his trident and use his power
to sink ships.

Energy from Earth


Gaia the power of the Earth
and creator of all life. The force of
elemental power deciding the destiny
of all life on Earth.
With her maternal warmth, Gaia both
protected the Earth and personified
the consciousness
of the natural planet.

Eaton is a diversified and globally active


technology leader and service company
in the business fields of Electrical, Fluid Power,
Truck und Automotive.
Eatons Electrical Sector is a global leader
in distributing, controlling and switching power,
and a global supplier of products and services
for uninterrupted power supply and industrial
automation.
Eatons Electrical Sector includes brands such as
Cutler-Hammer, MGE Office Protection SystemsTM,
Powerware, Holec, MEM, Santak and Moeller.

Published by: Eaton GmbH


Scheydgasse 42
1215 Vienna
2011 by Eaton GmbH, Austria
Subject to technical modifications. No responsibility is taken for misprints or errata.
Printed in Austria (05/11)
Graphic design: SRA
Print: Rabl, Schrems
BR01601001Z-EN
Article No. 156893