Anda di halaman 1dari 52

YES Slim & YES Super Series

Commercial DC Inverter VRF Air-conDITIONERs You Can Trust

Table of Contents
Serving your needs since 1874

Product Benefits

Product Features

Product Functions

Product Technologies

11

Indoor Units

21

Smart Control

27

Fresh Air System

31

Product Nomenclature

33

Product Portfolio

34

Product Specifications

36

Serving Your Needs Since 1874.


A century of innovation
Established in 1874 in York, Pennsylvania, YORK has

Significant Milestones

helped our customers meet their temperature control

1935

needs for over a century.

First to develop a successful single-room air


conditioner

Now a Johnson Controls brand, YORK continues to


benefit customers through research that has gone on to
claim several significant firsts in design and innovation.
Johnson Controls is able to provide our customers with
the best temperature control solutions available around
the world today.

Pioneer in Inverter technology


Our customers can be assured that they will enjoy the
benefits of the latest technology when they choose a
Johnson Controls product, as YORK has always been
at the forefront of adopting new technologies for their
offerings.
From being the first to offer a low pressure VSD unit in

1954
First to offer year-round air-conditioning

1979
Launched the first Low Pressure VSD Driven
Centrifugal Chiller

2004
Launched the first VSD Driven Air Cooled
Screw Chiller

2005
Applied VSD in YORK Industrial Refrigeration
Screw Chiller

2011

century, YORK has demonstrated its pioneering spirit.

Launched the YES Mini Residential Inverter


VRF, Magnetic VSD Centrifugal Chiller, VSD
Driven Water Cooled Screw Chiller

Leader in reliability

2012

When constructing products, YORK places our

Launched the YES Slim Residential/


Commercial Inverter VRF, YES Super
Commercial Inverter VRF

1979 to introducing the inverter technology in the 21st

customers needs as the top priority of our design


process.
Our inverter VRF units are produced using state-ofthe-art lean manufacturing techniques, and rigorous
quality testing is implemented at every step of the
manufacturing process, before they are shipped to
customers.

YES Slim & YES Super | 1

Endorsed by Iconic Buildings.


YORKs HVAC systems have been installed in many of the worlds most famous landmarks. YORK makes systems for structures of all sizes that bring innovation, comfort and design wherever people live, work and play.

2 | YES Slim & YES Super

Product Benefits
YORK Variable Refrigerant Flow (VRF)
At Johnson Controls, we always seek to anticipate what customers are looking for and strive to provide the
temperature control systems that will meet their myriad of needs.
YORK VRF air-conditioners offer customers a range of benefits that is unparalleled in the air-conditioner
market.

Energy Efficient
Customers looking to save money will be delighted to know our air-conditioners can help
reduce costs as the highly energy-efficient VRF units will help you decrease the power
you use.

Wide Ambient Range


Customers can take comfort in knowing that our inverter VRF air-conditioners can
operate in extreme weather conditions, running safely even when ambient temperature is
up to 52C for cooling or -20C for heating.
48 to 52C cooling for YES Slim & YES super or -15 to -20C heating for YES Slim will be running at
intervals.

Smart Control
Customers can take more effective control of their air-conditioners with a variety of
technology tools available for our units. Our advanced suite of control solutions include:
three types of touch screen controllers, smart home connection and building automation
systems using the Metasys software.

Versatility
We understand that no two customers are the same. Thats why weve designed our
air-conditioning systems to be versatile enough to meet our customers differing needs.
From product selection to installation to commissioning, YORK YES Series offers
impressive flexibility.

Greater Comfort
We know that enjoying comfort at the right temperature is one of our customers
foremost desires. We have the technology to deliver that comfort, including a BLDC
(Brushless Direct Current) fan motor with adjustable speeds, anti-vibration and soundinsulation technology.

YES Slim & YES Super | 3

Product Features
Environmental Protection
Our highly energy efficient Inverter VRF units provide environmental protection by
using the eco-friendly R410A refrigerant.

Air Cooled Inverter Driver


They also carry the air cooled inverter driver, a core component which uses air-cooled
heat rejection technology for higher energy efficiency.

Independent Oil Circuit Design


The independent oil circuit design allows the oil balance system to be kept separate from the
cooling and heating operation, thereby avoiding the frequent switching of the compressor and improves sustainability and energy efficiency.
Outdoor unit

Outdoor unit

Oil transport distribution station


Oil balance pipe between units

Wide Ambient Range


52C

-20C

With wide ambient temperatures ranging from 52C in cooling mode to -20C in heating mode, the outdoor unit can work in any adverse environment

High ESP Discharge Air


The ESP discharge air of the system can reach up to 80 Pa, which guarantees stable
cooling and heating, making it suitable for any outdoor space or machine rooms of multistorey structures.

Touch Screen Wired Controller


Take control of your system with our touch screen wired controller that is available in
four different colours. It has a built-in wireless remote controller receiver to control the
indoor unit, as well as a real-time temperature sensor.

4 | YES Slim & YES Super

Multi-point Data Collection


Maintain and repair your outdoor units easily with a Service Controller, which allows to
be connected to any indoor unit in the same network to do multi-point data collection.

Decrease cutting surface


to reduce corrosion risk

Outdoor Unit Anti-Corrosion Fins

Water do not
accumulate in the
gap between fins
and can drip
down easily to
reduce corrosion
risk.

Our units also have outdoor unit anti-corrosion fins which are made from hydrophilic
aluminium and help the outdoor units defrost quickly and get rid of condensation. The

Wave-shaped Fin

Water does not accumulate


in the gap between fins
and can drip down easily
to reduce corrosion risk.

anti-corrosion coating and wave-shape reduces the cutting surfaces, thereby prolonging
the life of the fin significantly.

Combined Electronic Expansion Valves and


Check Valve Throttle Device
With a commitment to fine quality, our VRF units make use of the combined electronic
expansion valves and check valve throttle device which helps to prolong product
usage by reducing the working time of the electronic expansion valve. Our large capacity outdoor units are equipped with double electronic expansion valves, which increase the
response speed of the flow control and heating mode.

Complete System Protection for High Reliability


Our VRF air-conditioners come thoroughly equipped with a complete system protection for high reliability, which includes:
Communication Fault Protection

Inverter Fault Protection

Temperature Sensor Protection

Pressure Sensor Protection

Insufficient Refrigerant Protection

Compressor Fault Protection

Compressor Overcurrent Protection BLDC Fault Protection


Discharge Temperature Protection

Discharge Pressure Protection

Suction Pressure Protection

Low Pressure Switch Protection

Intelligent Debugging Operation


With an intelligent debugging operation, an alarm will be triggered if any communication errors are detected between the indoor and outdoor units. Automatic
alerts will also be sent when service stop valves are opened or closed.

YES Slim & YES Super | 5

Improved Indoor Air Quality


Nano-TiO2 sterilizers are also in place, which enables up to 95% completion of sterilization in 6 hours, allowing improved indoor air quality.
Ultraviolet Photo
Catalysis

Polluted Air

Nano-TiO2

Nano-TiO2

Polluted Air
Fresh Air

Moderate Height Difference Allowance


From installation to commissioning to product selection, YORK YES Series offers
unparalleled flexibility. For example, moderate height difference allowance enables
outdoor units with some height difference to be installed within the same system.

Refrigerant
Connect To Indoor
Units

Height Difference
Between Modular
Less Than 5m

Intelligent Weather-Proofing
You can now maximise comfort throughout the day with our inverter VRF air-conditioners as they come with intelligent weather-proofing that allows pressure and temperature sensors to collect pre/post-defrosting data to derive the optimal defrost setting,
maintaining a high performance in heating and cooling operations under strong winds.

6 | YES Slim & YES Super

Double Fan Design and Noise Reduction Technology


The double fan design, which enables a lower airflow volume as compared to a single
fan, and the noise reduction technology, made possible by DC Scroll inverter compressors, BLDC fan motor with adjustable speeds, anti-vibration and sound-insulation technology, ensures that the air-conditioners operate quietly by cutting down the operational
noise levels.

Non-stop Oil Return at Heating


Through the computation of accumulated operation time, real-time system partial loading, temperature and pressure data, the system can determine when to activate the nonstop oil return at heating without switching to cooling mode, thereby offering continuous heating to the users.

YES Slim & YES Super | 7

Product Functions
Optimization in Operation of Indoor Units
Our system can detect and promptly compare real-time pressure and temperature parameters, then optimizes the indoor unit operation by automatically adjusting the pressure and compressor running frequencies.

High Pressure
Sensor

Far end indoor units


refrigerant flow increased

a
m
de
onm
Defrost
te
&
pressure

Heat storage

an
d

n
d
by
tu r
e

sure

a
m
de
n
o
em
Defrost
&t
pressure

an
d

nd
by
ure

at

st
fro
de

lt r
m id
tu
i
ex t y d e f ro s t a
t ra
u re
t
-low
a
te m p er

pe
r

Silent Operation Function

Hu

Far end indoor units


refrigerant flow increased

Our intelligent defrost system ensures comfort at heating.

ra

Intelligent Defrost

st
fro
de

pe

Low Pressure
Sensor

After 1hr

Heat storage

The outdoor unit also automatically detects real-time changes in environmental temperature and operation pressure, and adjusts to silent mode accordingly.

Auto-restart Function

Operation mode
before power cut off

Hu

lt r
m id
tu
i
ex t y d e f ro s t a
e
t ra
t ur
-low
t e m p e ra

Automatic restart and


Recovery recover to the
operation mode before
power cut off

In case of accidental power failure, the system auto-restarts and recovers to the former
operation mode.

After 1hr

Operation modemode
before
Operation
power cut off
before power cut off

8 | YES Slim & YES Super

Automatic restart
and recovery
Automatic
restart
and
to the operation
mode
Recovery
recover
to the
operation mode before
power cut off

LED Display
The diagnosis and display of LED error codes helps shorten service time by technicians.

Refrigerant Recovery
If the indoor unit or outdoor unit fails in the system, the refrigerant can be recovered to
reduce its wastage.

Max Operating Frequency Setting Function


When there is a limited capacity of power distribution, users have the option to set a
maximum compressor frequency ratio, ensuring economical returns and stability.

Can set max compressor frequency


Tackles the lack of power distribution
in renovation of buildings
More economical and stable
Better performance in case
of a power shortage

Maximum Frequency Limit


Operation

Compressor Rotation Operation


The compressor rotation operation effectively spreads the operation time of each
compressor,extending the unit life.

1st Circle:
2nd Circle:
3rd Circle:

YES Slim & YES Super | 9

1st Circle:
2nd Circle:
3rd Circle:

Double Backup Operation


If one compressor fails, the other compressor(s) can keep running if no oil contamination
occurs.
If one outdoor unit fails, the other outdoor unit(s) can keep running if no oil contamination occurs.

Single Modular

Combination Units

Failed
Failed

Stop Running Backup Running

10 | YES Slim & YES Super

Backup Running

Product Technologies
Stepless Inverter Technology
Our system adopts advanced DC inverter drivers with higher sensitivity, lower power
consumption and lower heat loss. It keeps a good balance between the accuracy of adjustment and response time, thereby ensuring a fast response and enough accuracy. The
accuracy of adjustment can reach 0.01HZ, and the capacity can be adjusted steplessly.

Precision

Fast Step Jump

Traditional Inverter
Technology

YORK Inverter
Technology

Precision

Fast Step Jump

180DC Inverter Driver Control Technology

YES S Series adopts the advanced phase voltage signal sampling method, and can measure the force trends of the motor speed and rotor, improving the running efficiency of
the motor through having the DC inverter driver
transmit
sine-curve
waves.
Traditional
Inverter regular
YORK
Inverter
Technology

Technology

There are three groups of terminals in the inverter compressor electric box, providing the
DC inverter driver access to the terminal to drive the stator coil of the DC brushless motor within the compressor. The connected circuit, under a certain time order, has the DC
motor generate a 360 magnetic field.
A 180 DC inverter control enables the stator coil to always have current steadily running
through to make it stable.

Normal 120Communication Square


Wave Drive Mode

YORK 180Communication Sine


Wave Drive Mode

Phase Current

Phase Current

ombination Units

U Phase

U Phase

V Phase

V Phase

W Phase

W Phase

Backup Running

YES Slim & YES Super | 11

High Performance Mainboard Chip


Our outdoor units use the ARM CORTEX-M3, which has the 32Bit
72Mhz high-speed chip.
This chip has the highest performance in the industry, and improves the calculation efficiency of the DC inverter while reducing
the power consumption of the transformer or other system parts.

Powerful Permanent Magnets


Our compressor motor rotors use powerful permanent magnets
made from rare earth. Compared with the normal ferrite magnets, it has stronger magnetic and heat resistance, which provides
greater torque, lower power consumption, with higher reliability
and energy efficiency.
Strong Magnetic Rotor
of Compressor Motor

Traditional Compressor
Motor

DC Inverter Technology
Our YES-S Series outdoor units feature the DC inverter compressor and DC fan motor,
which enable more efficient and quiet operations.

DC Brushless Fan Motor

DC Brushless Fan Motor


Compressor Inverter Driver

12 | YES Slim & YES Super

Soft Start
Variable frequency soft start technology can achieve the required capacity output of
indoor units within a short period.
Capacity HP

Capacity HP

Time Min

12

16

20

Time Min

4
8
12
16
20
High Pressure
Chamber
Scroll
Compressor

24

24

28

28

32

32

High pressure chamber scroll compressors directly gets the suction refrigerant from the
indoor unit back to the compression cylinder. The refrigerant is not heated by the mo20

16

24

28

32

tor, so it can get a better compression ratio and a relatively high energy efficiency. The
pressure of the refrigerant with high temperature and pressure in the crank case can be
adjusted automatically. and then discharged from the exhaust, which has a similar function as the static pressure box, and allows the noise to be effectively controlled.
High Pressure Chamber
System Refrigerant Circulation Diagram (Pressure-Enthalpy)

lg pSystem Refrigerant Circulation Diagram (Pressure-Enthalpy)

sure-Enthalpy)

High Pressure Chamber


Scroll Compressor

lg p

3 3
c

,
3 3
4

refrigerant system diagram

YORK high pressure cell


refrigerant system diagram

High Pressure Chamber


Scroll Compressor

,
2
2

2
2

YORK high pressure cell


refrigerant system diagram

,
1
a

Scroll Compressor

Other refrigerant system diagram

Other refrigerant system diagram

High-efficiency Oil Separator


The cover of the oil separator uses a centrifugal rotary steering design. Refrigerant gas
goes into the oil separators and then immediately gains a high rotating speed. This,
together with the centrifugal force separates the heavier oil gas from the refrigerant. The
oil gas is liquefied and finally drops to the storage device across the walls of the separator, thereby finishing the separation process.

YES Slim & YES Super | 13

Non-stop Compressor, Cross Oil Balance Protection Technology


Through reasonable oil control logic, with the large volume of accumulator (with oil
storage function), and the specific tubing, the system can complete the cross oil balance protection process. The compressor does not need to stop throughout the whole
process, making the operation of the air-conditioning system more reliable and efficient
while without affecting the indoor effect.
Application of Oil balance on Single Unit
Oil balance between the unit inside compressors: After the oil in the second compressor is separated in the oil separator, it will enter the crank case oil groove in the first compressor by oil pipe, and
after the oil in the first compressor is separated in the oil separator, it will enter the accumulator oil
groove by pipe. Oil will be transported to two compressors by suction pipe, so the compressor does
not need to stop and ensure that two compressors can gain lubrication by oil at the same time.

Suction

Discharge

Application of Oil balance on combined units


Oil balance between modules uses the pressure-difference method. After separation in the oil
seperator, the oil is divided into two branches, with one of them flowing to the liquid separator
and the other one going into another module. The oil pressure in oil separator is high and the oil
pressure in liquid is low. When the solenoid valve in branch to another module (1) is open, and the
solenoid valve in liquid separator pipe of another module (2) is open, the differential pressure will
automatically engage the oil from oil separator of the first module to liquid separator of the second
module, thus completing the oil balance between modules.

2
ON

OFF
OFF

ON

SV Close

14 | YES Slim & YES Super

SV Open

Double Oil Separation Technology


This technology ensures the compressor is neither in short nor excessive supply of oil,
thereby guaranteeing high reliability and efficiency. Since deep oil separation technology
has been in application on large variable frequency chillers for many years, inverter VRF
also refers to the experience of large systems, using double oil cleaning technology. The
compressor has an oil separation function, and a newly added high-efficiency oil separator to do double oil separation at the same time.

Compressor

Discharge pipe
Inside oil
separation

Oilseparator
separator
Oil

Compressor
Compressor
discharge
discharge

System
System discharge
discharge
Evaporator

Double
Double oil
oil separation
separation

Ref. route
Oil route

Compressor
discharge

Nozzle with injector


Filter

System discharge

Double oil separation


System suction (liquid)
Oil return
Compressor suction

Oil separator
in condenser
Liquid supply line

System
System suction
suction (liquid)
(liquid)

Accumulator

Ref.
Ref. route
route
Oil
Oil route
route

Evaporator oil
return pipe

Suction pipe

Double oil
YORK
separation pipeline
YORK Inverter
Inverter VRF
VRF Double
Double Oil
Oil Separating
Separating
Technology
Triple
oil
separation
pipeline
Technology

YORK Inverter VRF Double Oil Separating


Technology

Oil separator

YORK Chiller Multiple Deep Oil Separating


Technology

Compressor, with
oil separation
function inside
First oil separation

Oil
Oil return
return

Accumulator
Accumulator

Compressor
Compressor suction
suction

Over Compression Prevention Technology

Compressor,
Compressor, with
with
oil
oil separation
separation
function
inside
function inside

The load and requirement of refrigerant in VRF systems are changing. As the load volume

First
First oil
oil separation
separation

can influence frequency, whether the system is intelligent makes


High a big difference.
pressure
sensor

1. The system uses a high-pressure sensor to detect the


discharge pressure, then adjusts the fan motor to ensure the
discharge pressure does not exceed the allowable range.
High
High
pressure
pressure
sensor
sensor

2. Pressure relief vents are available in the compressor cylinder.


When over-compression happens, the corresponding

Flow of refrigerant

pressure-relief vents will be automatically pushed against the


linked spring to release pressure and refrigerant gas,
thereby
High pressure
preventing over compression.
The formation
of continuous
oil film
Pressure-difference
oil pipe

discharge chamber

Connected to low
pressure suction end of
asymmetric vortex plate

Flow
Flow of
of refrigerant
refrigerant

YES Slim & YES Super | 15


High
High pressure
pressure
discharge
discharge chamber
chamber

Continuous Oil Film Lubricating


Technology
Flow of refrigerant

The oil supply in the compressor is powered by the pressure difference in the highpressure chamber and creates consistently
stable oil film adherent to the wall, pro-

High pressure
discharge chamber

moting the effective lubrication between


the moving and fixed scrolls, sealing of

The formation
of continuous
oil film

compression chamber, cooling of the wall


Connected to low
pressure suction end of
asymmetric vortex plate

Pressure-difference
oil pipe

of the cavity, etc and reducing the friction


loss and noise in the operation.

Intelligent Refrigerant Storage Technology


1. Through the high and low pressure sensors which control the amount of compression and discharge of the compressor, the excess refrigerant is stored in the pipeline
of the system.
2. The accumulator provides storage space required for both defrosting and oil return,
thus preventing the compressor from operating with liquid slugging. This ensures that
the system runs with higher reliability and stability.

Powerful Permanent Magnets


Outdoor dual fans are configured with high efficient, low noise BLDC motor and up to
40-step air-flow adjustment, enabling more accurate unit capacity output.

BLDC Motor

Efficiency%

100
080

AC Motor

060
040
020
0

100

200

300

400

500

600

SpeedRPM

16 | YES Slim & YES Super

700

800

900

1000

BLDC Motor

Efficiency%

100
080

AC Motor

060
040
020
0

100

200

300

400

500

600

700

800

900

1000

SpeedRPM

Integral Design of Axial-flow Fan & Fan Guide Technology


According to our research, reduction of the axial-flow fan blades and fan guide space can
enhance the aerodynamic performance. When the ratio of tip clearance and fan diameter
decreases from 3% to 1%, air flow can increase by 10%, thus improving the efficiency of
the fan motor and reducing noise.

High-efficiency Heat Exchanger


1. For large-capacity units, it uses 3-row

3-row
heat-exchanger

heat-exchangers to improve heat


emission in summer and endothermic
ability in winter to ensure the heat
exchange effect.

2. The pipe is processed with internal tread piping that can add more turbulence to the
flow of the refrigerant and enlarge the heat-exchanging surface. Also, it adopts corrugated expansion-connected fins to add air passageway and heat transmission of
the gas on the air-cooling side.

Internal tread piping

Internal tread piping

Ref.
Ref.

3. The advanced 2-in and 1-out circuit design can increase the proportion of liquid
refrigerant and the heat exchanging rate of the refrigerant, thereby enhancing heat
exchanging effect and efficiency.
Traditional ref. circuit design
Gas refrigerant

Liquid refrigerant

Traditional ref. circuit design

Liquid refrigerant

Gas refrigerant

New-type ref. circuit design


New-type ref. circuit design

Gas refrigerant

Liquid refrigerant
Liquid refrigerant

Gas refrigerant

Increase liquid status


to improve heat

Gas

Gas refrigerant
Gas refrigerant

Gas

Gas-liquid

Gas-liquid mixture
Liquid
mixture

Increase liquid status


exchange efficient
to improve heat
exchange efficient

Liquid

Liquid refrigerant
Liquid refrigerant

YES Slim & YES Super | 17

Increase liquid status


to improve heat
exchange efficient
Gas refrigerant

Gas

Gas-liquid
mixture

Liquid

Liquid refrigerant

High-efficiency Plate Heat Exchanger Sub-cooling Technology


In order to ensure long piping's performance, a plate-type heat exchanger is used as a
sub-cooler to achieve up to 20C sub-cooling temperature.

Up to 20C
sub-cooling

er

Intelligent Piping Length Adaption Technology


The system mainly uses high and low pressure as data for control. As for long piping,
indoor electronic expansion valve and outdoor sub-cooling can self-adapt in accordance
with the target low pressure, which can not only ensure long-distance delivery of cooling
capacity, but also solve the problem of bias indoor flow, sparing human setting codes for
pipe length, increasing integral comfort of the room and considerably saving debugging
work during installation.

Automatically close to target pressure

Target pressure

Automatically determine pressure loss

Long piping
installation

Automatically improve capacity correction

18 | YES Slim & YES Super

Automatically determine pressure loss

Target pressure

Long piping installation

Automatically improve capacity correction

Intelligent Defrost Technology


1. YORKs unique heat storage defrost technology
Before entering the defrost operation, the system will store an amount of heat for
defrost later. (This operation does not compromise the indoor comfort).
So it can reduce the liquid refrigerant return flow while defrosting, and can let the
refrigerant carry more calories and evaporate faster. This results in faster defrosting
by 50% compared to regular systematic defrosting.
It can also speed up the the heating after defrosting for better comfort. By contributing to the normal operation of compressors, it can ensure the system running stably
and reliably, increasing the defrost efficiency and the actual energy efficiency of the
whole system.

Outdoor coil
Adjust electronic
expansion valve

Accumulator
Indoor unit begins
heat storage
Reduce low temperature
refrigerant

Indoor unit

2. Defrost on demand
Our outdoor unit design has highaccuracy pressure and temperature
sensors. Through close cooperation,
they can detect the changes in
system data caused by outdoor
unit frosting, such as the pressure,

Frosting reaches a
certain level,
defrosting

temperature, duration of time, etc. and

No frost, no
need to defrost

then calculate the thickness of frost


intelligently.
Only when the thickness gets up to a certain level will the unit begin to defrost,

Frosting probability
Chronic freezing probability

ow

De

f ro

B el

-3

Chronic freezing,
intelligent extra low
temperature defrost

Intelligen
t

st

-3

st
fro
De

Ov
er

tackling problems like "frequent defrosting" or "incomplete defrosting".

I n t e lli g e n

YES Slim & YES Super | 19

-2

-4

-6

-8

-10

Environmental temperature

3. Extra low temperature intelligent defrost


When the outdoor temperature is below -3C, the outdoor humidity is very low,
and the air conditioning is generally not easy to frost, but easy to chronically form a
sheet of ice. After some time, this will cause ice accumulation.
In such circumstances, the system will enable extra low temperature intelligent
defrost mode, which can solve the problems of chronic icing and avoid frost free
defrost.

Frosting probability
Chronic freezing probability

Chronic freezing,
intelligent extra low
temperature defrost

-2

-4

-6

-8

-10

Environmental temperature

4. For high-humidity environments, it can run through varieddefrost cycles with


different strengths.

Pressure & Temperature Combined Control


Our system has a full range of sensors including high pressure, low pressure, discharge
temperature, heat exchanger temperature, environmental temperature, suction temperature, coil outlet temperature, and liquid pipe temperature sensors. Comprehensive
safeguards can make the system more efficient, stable, reliable and comfortable.

20 | YES Slim & YES Super

Indoor Units
Round-way Cassette
Fresh air Intake

360 degree circulation


Room temperature, airflow, and noise control are
regulated and maintained throughout the room.
Blind angles of air distribution

Minified blind angles

Oblique view

Oblique view

360good air distribution

Elevation view

Elevation view

Different height setting


Normal ceiling mode or high ceiling mode can be set
by wired controllers to achieve effectiveness and comfort ability at the same time.

Oblique view

Elevation view

Fresh air intake


Fresh air can be introduced directly.

Fresh air Intake

Fresh air Intake

Brushless Direct Current (BLDC) fan motor


With BLDC motor, the fan speed can be adjusted to
reduce the noise and improve the efficiency.

r distribution

Fresh air Intake

High efficiency drainage pump


The drainage pump is available with 750mm head.

YES Slim & YES Super | 21

Compact Ducted Indoor Unit


Compact design
45

mm

0
70

0m

With a height of just 200mm and depth of 450mm,

Part ceiling
Narrow corridor
installation

its compact size makes installation ideal for narrow


spaces such as corridor of bedrooms or hotel rooms.

Flexible air return


The air return baffle is detachable. The direction of
air return can be adjusted during installation, either
downward or backward.

ESP adjustable
The external static pressure of the ceiling-packaged
indoor unit is adjustable, supporting different installations and delivering optimal airflow.

0~30Pa

1.8kW~7.1kW

Sleep mode
Sleep mode can be selected via a wired controller.

Optional drainage pump


0~30Pa

2.0kW~5.3kW

15~80Pa

Ceiling
6.6kW~11.5kW

15~100Pa

14kW~17.5kW

22 | YES Slim & YES Super

The ceiling-packaged indoor unit fits in the narrowest


of spaces where the drainage pump is not required.
However, if there is enough room in the ceiling and the

(Unit: mm)

drainage distance is long, a drainage pump is available.

Ceiling-packaged Duct (Low Static)


Compact design
m

0m

70

With a height of just 200mm and depth of 450mm,

Part ceiling
Narrow corridor
installation

its compact size makes installation ideal for narrow


spaces such as corridor of bedrooms or hotel rooms.

Flexible air return


0~30Pa

1.8kW~5.3kW

15~80Pa

6.6kW~11.5kW

15~100Pa

14kW~17.5kW

The air return baffle is detachable. The direction of


air return can be adjusted during installation, either
downward or backward.

ESP adjustable
The external static pressure of the ceiling-packaged
indoor unit is adjustable, supporting different installations and delivering optimal airflow.

0~30Pa

2.0kW~5.3kW

15~80Pa

6.6kW~11.5kW

15~100Pa

14kW~17.5kW

Sleep mode
Sleep mode can be selected via a wired controller.

Optional drainage pump


The ceiling-packaged indoor unit fits in the narrowest
of spaces where the drainage pump is not required.

Ceiling

However, if there is enough room in the ceiling and the


(Unit: mm)

drainage distance is long, a drainage pump is available.

YES Slim & YES Super | 23

Floor-concealed Indoor Unit


Complete product line
Four models ranging from 2.8kW to 7.1kW are available for selection.

Better air distribution


Top air outlet

Side air outlet

York air outlet

Our special 45-degree angle design for the air outlets


helps to optimize air distribution for both cooling &
heating.

Compact design
A compact design with a uniform 230mm depth &
600mm height is adopted for all models, and is suit600mm

able for floor-concealed installations in cabinets


730~1334mm

230mm

0~30Pa

1.8kW~5.3kW

15~80Pa

6.6kW~11.5kW

15~100Pa

14kW~17.5kW

Medium Static Duct


ESP adjustable
The external static pressure of the ceiling-concealed
indoor unit is adjustable, supporting different installa-

eiling packaged indoor


ds up the pace at
n the air-conditioner.

tions and delivering optimal airflow.


0~30Pa

2.0kW~5.3kW

15~80Pa

6.6kW~11.5kW

15~100Pa

14kW~17.5kW

Sleep mode

indoor unit is ideal for

Sleep mode can be selected via a wired controller.

edrooms. Sleep mode can

24 | YES Slim & YES Super

tra- slim and fits in the

pump is not required.

ceiling and the drainage

Ceiling

2-Way Cassette
Complete product line
Seven models ranging from 2.8kW to 11.2kW are available for selection.

520mm

Compact design
A compact design with uniform 520mm depth and
310mm height is adopted for all models, making in-

310mm

stallations easier.
840~1440mm

Max=500mm

Standard drainage pump


The unit has a standard drainage pump capable of
draining water up to 500mm, and is ideal for draining
condensation over longer distances.

Standard

High Wall Indoor Unit


Complete product line
Five models ranging from 2.2kW to 7.1kW are available for selection. Suitable for residential & light commercial
applications with their compact sizes and attractive design.

Whole Package Design


Electronic Expansion Valve (EEV) fitted inside the unit
chamber makes it a package design, doing away with
the need for external installations.

Low noise
High efficiency/low noise motors and fan impellers are
adopted to enable quiet operation down to 28dB(A). In
addition, there is a standard filter for a healthier use.

YES Slim & YES Super | 25

Floor/Ceiling
Complete product line
Eight models ranging from 2.8kW to 11.2kW are available for selection. Floor and
ceiling installations are convertible for job sites.

Compact design
A compact design with uniform 240mm depth and
680mm height is adopted for all models, making installations easier.

680mm
240mm

1245~1670mm

Optional drainage pump


Max=500mm

An optional drainage pump for a ceiling installation is


available. It is capable of draining water up to 500mm,
and is ideal for draining condensation over longer
distances.

Option

26 | YES Slim & YES Super

Smart Control
Individual & group control
Every indoor unit in the YES system can be controlled via the wired and wireless controllers. Whats more, the wired controller has a group control function and can connect up
to four indoor units.

Wired
Controller

Wireless
Controller

Group
Control

Group
Control

Individual
Control

Our touch screen wired controllers come in multiple color options, and are equipped with
TiO2 control and wireless controller receivers.

Gray

Sky blue

Green

Brown

YES Slim & YES Super | 27

On/Off Controller
Our touch screen on/off controllers can connect up to 256 indoor units or 4 VRF systems.
It can turn on or off the indoor units within the same zone at the same time.
** YDHW/YDCC can't connect to on/off controller.

ON/OFF controller which can support Modbus or BACnet


protocol for different application (need to choose the
corresponding type of the controller).

Central on/off control


at the entrance/exit

Central Controller
Our 7-inch touch screen central controller can be mounted on the wall easily. It can
connect up to 1,024 indoor units/512 groups/128 zones/16 VRF systems, and can achieve
the same control functions as the wired controller. In addition, it has a weekly schedule
function.
** YDHW/YDCC cant connect to central controller.
Central controller can
support Modbus or BACnet
protocol for different application (need to select
the protocol mode).

28 | YES Slim & YES Super

Door Card Function


A door card on/off signal function is available on the YES indoor unit control board and
features two selection modes. Users can choose one of the two functions shown below
by using the door card and signal interface communication.
Mode 1
The system returns to the last operation mode automatically when the card is inserted.

Door Card
Door Card

Insert the
door card

Pull out the


door card

Mode 2
The system has to be switched on manually when the card is inserted, so as to reduce
any wastage of electricity.

Door Card

Door Card

Insert the
door card

Door Card

Pull out
the door
card

YES Slim & YES Super | 29

BAS Connection
Our YES Series can be connected to the Building Automation System for an integrated
smart control solution.
** YDHW/YDCC cant connect to BAS connection.

Metasys/Other
BAS System

NAE Converter (JCI)

BACnet

BACnet/IP

30 | YES Slim & YES Super

BACnet
communication
board

Fresh Air System


Complete Product Line
There are 10 models ranging from 510m3/h to 6000m3/h available and are suitable for
residential and commercial applications.

LOW

HIGH

High ESP (External Static Pressure)


The maximum ESP is up to 300Pa for long duct design of large space applications.

Wide Ambient Range


YORK Fresh Air Units can work in conditions with ambient temperatures from -7 to
46C, capable of running all year round.

Energy-saving Mode
Under auto mode, fresh air units can switch to ventilation automatically at mild ambient,
thus reducing energy consumption.

Hot ambient

Mild ambient

Cold ambient

Three Connection Types


For all models, 1 fresh air indoor unit can be connected to 1 outdoor unit.
For models 0510/1080 /1680/2100, multi indoor units (all fresh air type or mixed types)
are allowed to connect to 1 outdoor unit.

Single-Connection

Multi-Connection with Mixed Types


(Fresh air & standard type indoor)

Multi-Connection
with All Fresh Air Type Indoor

YES Slim & YES Super | 31

Connection conditions:
1. For all models: the capacity ratio of indoor units (including fresh air) must be 80%
100% .
2. For multi-connection with mixed types, the capacity ratio of fresh air units must be
below 30%.
3. For single-connection type, the outdoor model is fixed (and cannot be changed).

Filter Cleaning Alarm


There are six time interval options and three air pollution levels for filter cleaning alarm
setting.

150
hours

Default
2500
hours

1250
hours

5000
hours
Unlimited

32 | YES Slim & YES Super

9000
hours

Default
Mild
pollution
Medium
pollution
Heavy
pollution

Product Nomenclature
Outdoor Units
0 A 1

100

Condition 1: Export T1
Design Series No.
Design Code
Power Supply M: 380-415V/3-50Hz E:380V/3-50Hz
Refrigerant E:R410A
Outdoor Unit Type S:Single Unit V: Modular Unit
Structure H:Horizoatal Discharge V: Top Discharge
Cooling Capacity Code
H: Heat Pump
O: Outdoor Unit
V: DC Inverter
Y: YORK

E Series Indoor Units


0 E 3
Condition, 1: Export T1; 3: Export T3
Design Series Number: E Series(R410A)
Design Code
Power Supply A: 220V/1PH-50Hz, E: 380V/3PH-50Hz
Expansion Device, N: Internal EXV No Drainage Pump, P: Interal EXV With Drainage Pump
Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater
Mode of Operation, C: Cooling Only, H: Heat Pump
Cooling Capacity Code in 100W Air Flow Rate (M3/h) for YDCF
Indoor Unit Type,
CD: Compact Ducted, CP: Ceiling Packaged Ducted (Low Static), CK: Round-way Ceiling Cassette,
DK: 2-way Ceiling Cassette, EC: Floor/Ceiling, VC: Floor Conceal , HW: High Wall, CF: Fresh Air
D:Variable Refrigerant Flow(VRF) Air Conditioner
Y:YORK

C Series Indoor Units


H

F L E

2 C 3
Condition, 3: Export T3
Design Series Number: C Series(R410A)
Design Code
Power Supply, A: 220V/1PH-50Hz
Expansion Device, E: Internal
Piping, L:Left, R: Rightl
Return Plenum, F: With Back Return Plenum and Filter
Auxiliary Electric Heater 0: No Heater, 2: With 2# Heater, 4: With 4# Heater
Mode of Operation, C: Cooling Only, H: Heat Pump
Cooling Capacity Code in 100W
Indoor Unit Type, CC: Medium Static Ducted
D: Variable Refrigerant Flow(VRF) Air Conditioner
Y:YORK

YES Slim & YES Super | 33

Product Portfolio
Indoor
Cooling Capacities kW
Types

1.8

2.2

2.5

2.8

3.2

3.6

4.5

5.6

Compact Ducted

Low Static Duct (YDCP)

Medium Static Ducted (YDCC)*

High Wall (YDHW)

Y
Y

Floor/Ceiling (YDEC)

Floor-Concealed (YDVC)

2-Way Cassette (YDDK)

Round Way Cassette (YDCK)

Cooling Capacities kW
Types

6.3

7.1

Compact Ducted

Low Static Duct (YDCP)

Medium Static Ducted (YDCC)*

Y
Y

Floor/Ceiling (YDEC)

Floor-Concealed (YDVC)

2-Way Cassette (YDDK)

Y
Y

10

11.2

High Wall (YDHW)

Round Way Cassette (YDCK)

12.5

14

17.5

*approximate data

YES Slim Outdoor Unit Line-up


Capacity

Model

Cooling Capacity

Heating Capacity

8 HP

YVOH080HSEM

22.4kW

25.0kW

10HP

YVOH100HSEM

28.0kW

31.5kW

12 HP

YVOH120HSEM

33.5kW

35.0kW

34 | YES Slim & YES Super

Appearance

YES Super Outdoor Unit Line-up


Outdoor single modular consists of two types:
Single-fan and double-fan models are available.
With 2 HP increments, the outdoor unit can meet various capacity requirements.
Capacity

Model

Cooling Capacity

Heating Capacity

8 HP

YVOH080VVEE

25.2kW

28.0kW

10HP

YVOH100VVEE

28.0kW

31.5kW

12 HP

YVOH120VVEE

33.5kW

37.5kW

14HP

YVOH140VVEE

40.0kW

45.0kW

16HP

YVOH160VVEE

45.0kW

50.0kW

18HP

YVOH180VVEE

50.0kW

56.0kW

Product

Recommended Combination of Outdoor Units


Capacity

Cooling Capacity
YVOH
080VVEE

YVOH
100VVEE

YVOH
120VVEE

YVOH
140VVEE

YVOH
160VVEE

YVOH
180VVEE

20HP

22HP

24HP

26HP

28HP

30HP

32HP

34HP

36HP

38HP

40HP

42HP

44HP

46HP

48HP

50HP

52HP

54HP

YES Slim & YES Super | 35

Product Specifications
YES Slim Outdoor
Outdoor Unit Model

YVOH
080HSEM

YVOH
100HSEM

YVOH
120HSEM

HP

8HP

10HP

12HP

Power Supply (V/Ph/Hz)

380415/3/50

380415/3/50

380415/3/50

Cooling

22.4

28.0

33.5

Heating

25.0

31.5

35.0

Cooling

6.19

7.36

9.74

Heating

5.71

7.34

8.75

Nominal

4.80

6.00

7.20

Air Flow (m3/h)

9000

9000

10 000

Dimensions (mm)

HWD

1600 1100 400

1600 1100 400

1600 1100 400

Weight (kg)

Net Weight

180

200

200

Type

R410A

R410A

R410A

Charge (kg)

6.0

6.6

6.6

Anechoic Sound Level

53

56

58

Semi-Anechoic Sound Level

56

59

61

Liquid

9.52

9.52

12.70

Gas

19.05

22.23

25.40

Max Current

20.50

23.00

26.00

Breaker Current

25.00

32.00

32.00

Cooling nominal current

10.11

12.02

15.91

Heating nominal current

9.33

11.99

14.30

Capacity (kW)

Power (kW)
Compressor Output
(kW)

Refrigerant

Noise (dB(A))

Piping (mm)

Current (A)

Note:
1.

Cooling conditions: indoor 27CDB/ 19CWB, outdoor 35CDB, equivalent length 10m, IU/OU height difference 0m.

2.

Heating conditions: indoor 20CDB, outdoor 7CDB/6CWB, equivalent length 10m, IU/OU height difference 0m.

3.

Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per different installation and working conditions.

36 | YES Slim & YES Super

YES Super Basic


Outdoor Unit Model

YVOH
080VVEE

YVOH
100VVEE

YVOH
120VVEE

YVOH
140VVEE

YVOH
160VVEE

YVOH
180VVEE

HP

8HP

10HP

12HP

14HP

16HP

18HP

Power Supply (V/Ph/Hz)

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

Cooling

25.2

28.0

33.5

40.0

45.0

50.0

Heating

28.0

31.5

37.5

45.0

50.0

56.0

Cooling

6.59

7.51

9.50

10.77

11.57

15.25

Heating

6.65

7.79

10.4

10.96

12.43

14.86

Nominal

5.25

6.00

7.20

9.10

10.2

11.6

Air Flow (m3/h)

Cooling/Heating

10 500

10 500

10 500

17 500

17 500

17 500

Dimensions (mm)

HWD

Weight (kg)

Net Weight

Capacity (kW)

Power (kW)
Compressor Output
(kW)

1700 1000 760


210

210

1700 1300 760


225

Type

295

310

315

R410A

Refrigerant

Noise (dB(A))

Charge (kg)

8.0

8.0

8.5

10.0

10.0

10.5

Anechoic Sound Level

57

58

59

60

60

61

60

61

62

63

63

64

Liquid

9.52

9.52

12.7

12.7

12.7

15.88

Gas

19.05

22.23

25.4

25.4

28.58

28.58

Max Current

17.0

19.0

23.0

28.0

31.0

33.0

Breaker Current

25.0

25.0

32.0

40.0

40.0

50.0

Cooling nominal current

10.6

12.0

15.2

17.2

18.4

24.1

Heating nominal current

10.7

12.5

16.6

17.6

19.8

23.6

Semi-Anechoic Sound
Level

Piping (mm)

Current (A)

YES Slim & YES Super | 37

Recommended Combination Unit


Outdoor Unit Model

YVOH100
+
YVOH100

YVOH100
+
YVOH120

YVOH120
+
YVOH120

YVOH120
+
YVOH140

YVOH120
+
YVOH160

YVOH140
+
YVOH160

HP

20HP

22HP

24HP

26HP

28HP

30HP

Power Supply (V/Ph/Hz)

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

Cooling

56.0

61.5

67.0

73.5

78.5

85.0

Heating

63.0

69.0

75.0

82.5

87.5

95.0

Cooling

15.02

17.01

19.00

20.27

21.07

22.34

Heating

15.58

18.19

20.80

21.36

22.83

23.39

Nominal

12.0

13.2

14.4

16.3

17.4

19.3

Cooling/Heating

21 000

21 000

21 000

28 000

28 000

35 000

(1700 1000

(1700 1000

(1700 1000

760)

760)

760)

(1700 1300

(1700 1300

(1700 1300

760)

760)

760)

Capacity (kW)

Power (kW)
Compressor Output
(kW)
Air Flow (m3/h)

Dimensions (mm)

HWD

Weight (kg)

(1700 1000

760) 2

760) 2

760) 2

420

435

450

520

535

605

Type

R410A

R410A

R410A

R410A

R410A

R410A

Charge (kg)

16.0

16.5

17.0

18.5

18.5

20

Anechoic Sound Level

61

61

62

62

62

63

64

64

65

65

65

66

Liquid

15.88

15.88

15.88

19.05

19.05

19.05

Gas

28.58

28.58

28.58

34.9

34.9

34.9

Oil Balance

6.35

6.35

6.35

6.35

6.35

6.35

Max Current

38.0

42.0

46.0

51.0

54.0

59.0

Breaker Current

50.0

63.0

63.0

63.0

80.0

80.0

Cooling nominal current

24.0

27.2

30.4

32.4

33.6

35.6

Heating nominal current

25.0

29.1

33.2

34.2

36.4

37.4

Semi-Anechoic Sound
Level

Piping (mm)

Current (A)

(1700 1000

Net Weight

Refrigerant

Noise (dB(A))

(1700 1000

38 | YES Slim & YES Super

Recommended Combination Unit

Outdoor Unit Model

YVOH160
+
YVOH160

YVOH160
+
YVOH180

YVOH180
+
YVOH180

YVOH120
+
YVOH120
+
YVOH140

YVOH120
+
YVOH120
+
YVOH160

YVOH120
+
YVOH140
+
YVOH160

HP

32HP

34HP

36HP

38HP

40HP

42HP

Power Supply (V/Ph/Hz)

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

Cooling

90.0

95.0

100.0

107.0

112.0

118.5

Heating

100.0

106.0

112.0

120.0

125.0

132.5

Cooling

23.14

26.82

30.50

29.77

30.57

31.84

Heating

24.86

27.29

29.72

31.76

33.23

33.79

Compressor Output (kW)

Nominal

20.4

21.8

23.2

23.5

24.6

26.5

Air Flow (m3/h)

Cooling/Heating

35 000

35 000

35 000

38 500

38 500

45 500

(1700 1000

(1700 1000

(1700 1000

760) 2

760)

760)

2+

+2

(1700 1300

(1700 1300

(1700 1300

760)

760)

760)

Capacity (kW)

Power (kW)

Dimensions (mm)

Weight (kg)
Refrigerant

Noise (dB(A))

HWD

Current (A)

(1700 1300

(1700 1300

760) 2

760) 2

760) 2

Net Weight

620

625

630

745

760

830

Type

R410A

R410A

R410A

R410A

R410A

R410A

Charge (kg)

20.0

20.5

21.0

27.0

27.0

28.5

Anechoic Sound Level

63

63

64

64

64

64

66

66

67

67

67

67

Liquid

19.05

19.05

19.05

19.05

19.05

19.05

Gas

34.9

34.9

38.1

38.1

38.1

38.1

Oil Balance

6.35

6.35

6.35

6.35

6.35

6.35

Max Current

62.0

64.0

66.0

74.0

77.0

82.0

Breaker Current

80.0

80.0

100.0

100

100

100

Cooling nominal current

36.8

42.5

48.2

47.6

48.8

50.8

Heating nominal current

39.6

43.4

47.2

50.8

53.0

54.0

Semi-Anechoic Sound
Level

Piping (mm)

(1700 1300

YES Slim & YES Super | 39

Outdoor Unit Model

YVOH120
+
YVOH160
+
YVOH160

YVOH140
+
YVOH160
+
YVOH160

YVOH160
+
YVOH160
+
YVOH160

YVOH160
+
YVOH160
+
YVOH180

YVOH160
+
YVOH180
+
YVOH180

YVOH180
+
YVOH180
+
YVOH180

HP

44HP

46HP

48HP

50HP

52HP

54HP

Power Supply (V/Ph/Hz)

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

Cooling

123.5

130.0

135.0

140.0

145.0

150.0

Heating

137.5

145.0

150.0

156.0

162.0

168.0

Cooling

32.64

33.91

34.71

38.39

42.07

45.75

Heating

35.26

35.82

37.29

39.72

42.15

44.58

Nominal

27.6

29.5

30.6

32.0

33.4

34.8

Cooling/Heating

45 500

52 500

52 500

52 500

52 500

52 500

760)

(1700 1300

(1700 1300

(1700 1300

(1700 1300

(1700 1300

760)

760)

760)

760)

760)

2 (1700

Capacity (kW)

Power (kW)
Compressor Output
(kW)
Air Flow (m3/h)

(1700 1000
Dimensions (mm)

HWD

1300 760)
Weight (kg)

Net Weight

845

915

930

935

940

945

Type

R410A

R410A

R410A

R410A

R410A

R410A

Charge (kg)

28.5

30.0

30.0

30.5

31.0

31.5

Anechoic Sound Level

64

65

65

65

65

66

67

68

68

68

68

69

Liquid

19.05

19.05

19.05

19.05

19.05

19.05

Gas

38.1

38.1

38.1

38.1

38.1

38.1

Oil Balance

6.35

6.35

6.35

6.35

6.35

6.35

Max Current

85.0

90.0

93.0

95.0

97.0

99.0

Breaker Current

100

125.0

125.0

125.0

125.0

125.0

Cooling nominal current

52.0

54.0

55.2

60.9

66.6

72.3

Heating nominal current

56.2

57.2

59.4

63.2

67.0

70.8

Refrigerant

Noise (dB(A))

Semi-Anechoic Sound
Level

Piping (mm)

Current (A)

Note:
1.

Cooling conditions: indoor 27CDB/ 19CWB, outdoor 35CDB, equivalent length 10m, IU/OU height difference 0m.

2.

Heating conditions: indoor 20CDB, outdoor 7CDB/6CWB, equivalent length 10m, IU/OU height difference 0m.

3.

Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per different installation and working conditions.

4.

For combined models, clrcult breaker should be installed for not only the main power supply, but also the power supply of each module.

40 | YES Slim & YES Super

Compact Ducted Indoor Unit


Indoor Unit Model

YDCD
018
H0NA

YDCD
022
H0NA

YDCD
025
H0NA

YDCD
028
H0NA

YDCD
032
H0NA

YDCD
036
H0NA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

1.8

2.2

2.5

2.8

3.2

3.6

Heating

2.2

2.5

2.8

3.2

3.6

4.0

37

37

46

46

48

50

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.16

0.16

0.2

0.2

0.21

0.22

Air Flow (m3/h)

350

350

450

450

480

480

0(0-30)

0(0-30)

0(0-30)

0(0-30)

0(0-30)

0(0-30)

ESP (Pa)

Standard
(min-max)

Dimensions (mm)

HWD

200X700
X450

200X700
X450

200X700
X450

200X700
X450

200X700
X450

200X700
X450

Weight (kg)

Net Weight

23

23

23

23

23

25

Noise (dB(A))

H/M/L

29/25/23

29/25/23

31/27/25

31/27/25

32/29/27

32/29/27

Liquid/Gas

6.35/9.52

6.35/9.52

6.35/9.52

6.35/9.52

6.35/12.70

6.35/12.70

Drainage

DN25

DN25

DN25

DN25

DN25

DN25

Indoor Unit Model

YDCD
040
H0NA

YDCD
045
H0NA

YDCD
050
H0NA

YDCD
056
H0NA

YDCD
063
H0NA

YDCD
071
H0NA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

4.0

4.5

5.0

5.6

6.3

7.1

Heating

4.5

5.0

5.6

6.3

7.1

8.0

70

70

76

106

106

110

Piping (mm)

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.3

0.3

0.33

0.46

0.48

0.48

Air Flow (m3/h)

560

560

750

900

900

990

0(0-30)

0(0-30)

0(0-30)

0(0-30)

0(0-30)

0(0-30)

ESP (Pa)

Standard
(min-max)

Dimensions (mm)

HWD

200X700
X450

200X900
X450

200X900
X450

200X900
X450

200X1100
X450

200X1100
X450

Weight (kg)

Net Weight

25

30

34

34

34

34

Noise (dB(A))

H/M/L

38/35/32

35/32/29

35/32/29

39/36/32

37/34/31

37/35/32

Liquid/Gas

6.35/12.70

6.35/12.70

6.35/12.70

6.35/12.70

9.52/15.88

9.52/15.88

Drainage

DN25

DN25

DN25

DN25

DN25

DN25

Piping (mm)

YES Slim & YES Super | 41

Ceiling Packaged Duct (Low Static)


Indoor Unit Model

YDCP018H0NA

YDCP022H0NA

YDCP025H0NA

YDCP028H0NA

YDCP032H0NA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

1.8

2.2

2.5

2.8

3.2

Heating

2.2

2.5

2.8

3.2

3.6

37

37

46

46

48

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.16

0.16

0.20

0.20

0.21

Air Flow (m3/h)

Cooling/Heating

350

350

450

450

480

0 (030)

0 (030)

0 (030)

0 (030)

0 (030)

ESP (Pa)

Standard (min
max)

Dimensions (mm)

HWD

200 700 620

200 700 620

200 700 620

200 700 620

200 700 620

Weight (kg)

Net Weight

23

23

23

23

23

Noise (dB(A))

H/M/L

27/25/23

27/25/23

28/26/24

28/26/24

30/27/25

Liquid/Gas

6.35/9.52

6.35/9.52

6.35/9.52

6.35/9.52

6.35/12.7

Piping (mm)

Drainage

DN25

Indoor Unit Model

YDCP
036H0NA

YDCP
040H0NA

YDCP
045H0NA

YDCP
050H0NA

YDCP
056H0NA

YDCP
063H0NA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

3.6

4.0

4.5

5.0

5.6

6.3

Heating

4.0

4.5

5.0

5.6

6.3

7.1

Capacity (kW)

50

70

70

76

106

106

Current (A)

Power Input (W)


Nominal

0.22

0.3

0.3

0.33

0.46

0.48

Air Flow (m3/h)

Cooling/Heating

480

560

560

750

900

900

0 (030)

0 (030)

0 (030)

0 (030)

0 (030)

0 (030)

ESP (Pa)

Standard (min
max)

Dimensions (mm)

HWD

Weight (kg)

Net Weight

Noise (dB(A))
Piping (mm)

200 700 620


25

200900620

25

25

30

2001100620
34

34

H/M/L

30/27/25

35/32/29

35/32/29

33/31/28

37/34/30

35/33/29

Liquid/Gas

6.35/12.7

6.35/12.7

6.35/12.7

6.35/12.7

6.35/12.7

9.52/15.88

Drainage

DN25

Indoor Unit Model

YDCP071H0NA

YDCP080H0NA

YDCP090H0NA

YDCP100H0NA

YDCP112H0NA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

7.1

8.0

9.0

10.0

11.2

Heating

8.0

9.0

10.0

11.2

12.5

110

138

206

260

260

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.48

0.60

0.90

1.25

1.25

Air Flow (m3/h)

Cooling/Heating

990

1200

1500

1700

1700

0 (030)

15 (040)

15 (040)

15 (040)

15 (040)

2001100620

2001100620

ESP (Pa)

Standard (min
max)

Dimensions (mm)

HWD

Weight (kg)

Net Weight

34

34

48

48

48

Noise (dB(A))

H/M/L

36/33/30

39/36/31

39/36/31

41/37/33

41/37/33

Liquid/Gas

9.52/15.88

9.52/15.88

9.52/15.88

9.52/15.88

9.52/15.88

Piping (mm)

Drainage

42 | YES Slim & YES Super

220 1450 620

DN25

Medium Static Duct


Indoor Unit Model

YDCC
020H0FLEA

YDCC
025H0FLEA

YDCC
034H0FLEA

YDCC
045H0FLEA

YDCC
053H0FLEA

YDCC
066H0FLEA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

2.0

2.5

3.4

4.5

5.3

6.6

Heating

2.2

3.0

3.9

4.95

5.8

6.8

40

55

75

100

110

185

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.35

0.35

0.40

0.46

0.52

0.96

Air Flow (m3/h)

Standard

380

450

600

800

930

1200

15 (0/15/30)

15 (0/15/30)

15 (0/15/30)

15 (0/15/30)

15 (0/15/30)

15 (15/40/80)

226 1055

226 1175

226 1175

245 1475

602

602

602

576

ESP (Pa)

Standard (min
max)

Dimensions (mm)

HWD

226 855 602

226 855 602

Weight (kg)

Net Weight

20

20

23

25

25

32

Piping (mm)

Liquid/Gas

6.35/9.52

6.35/9.52

6.35/12.7

6.35/12.7

6.35/12.7

9.52/15.88

Drainage Piping (mm)

DN25

Indoor Unit Model

YDCC
078H0FLEA

YDCC
095H0FLEA

YDCC
115H0FLEA

YDCC
140H0FLEA

YDCC
175H0FLEA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

7.8

9.5

11.5

14.0

17.5

Heating

8.2

11.0

13.0

16.5

19.0

215

270

300

420

510

Capacity (kW)

Power Input (W)


Current (A)

Nominal

1.08

1.29

1.30

1.90

2.11

Air Flow (m3/h)

Standard

1360

1600

1900

2200

2700

15 (15/40/80)

15 (15/40/80)

15 (15/40/80)

15 (15/50/100)

15 (15/50/100)

ESP (Pa)

Standard (min
max)

Dimensions (mm)

HWD

245 1475 576

245 1805 576

245 1805 576

430 1563 655

430 1563 655

Weight (kg)

Net Weight

33

41

41

58

65

Piping (mm)

Liquid/Gas

9.52/15.88

9.52/15.88

9.52/15.88

9.52/15.88

9.52/15.88

Drainage Piping (mm)

DN25

YES Slim & YES Super | 43

Round-way Cassette
Indoor Unit Model

YDCK
028H0PA

YDCK
036H0PA

YDCK
040H0PA

YDCK
045H0PA

YDCK
050H0PA

YDCK
056H0PA

YDCK
063H0PA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

2.8

3.6

4.0

4.5

5.0

5.6

6.3

Heating

3.2

4.0

4.5

5.0

5.6

6.3

7.1

17

19

19

19

26

27

42

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.13

0.15

0.15

0.15

0.22

0.28

0.37

Air Flow (m3/h)

Standard

780

810

810

810

900

960

1100

246 840

246 840

246 840

246 840

246 840

246 840

246 840

840

840

840

840

840

840

840

50 950

50 950

50 950

50 950

50 950

50 950

50 950

950

950

950

950

950

950

950

Unit

23

23

23

23

26

26

26

Panel

5.5

5.5

5.5

5.5

5.5

5.5

5.5

H/M/L

28/27/25

29/28/26

29/28/26

29/28/26

31/29/27

32/31/28

32/31/28

Liquid/Gas

6.35/9.52

6.35/12.7

6.35/12.7

6.35/12.7

6.35/12.7

6.35/12.7

9.52/15.88

Unit (HWD)
Dimensions (mm)
Panel (HWD)

Weight (kg)

Noise (dB(A))

Piping (mm)
Drainage

DN25

Indoor Unit Model

YDCK
071H0PA

YDCK
080H0PA

YDCK
090H0PA

YDCK
100H0PA

YDCK
112H0PA

YDCK
125H0PA

YDCK
140H0PA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

7.1

8.0

9.0

10.0

11.2

12.5

14.0

Heating

8.0

9.0

10.0

11.2

12.5

14.0

16.0

42

63

63

129

129

142

171

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.37

0.54

0.54

1.07

1.07

1.17

1.39

Air Flow (m3/h)

Standard

1100

1500

1500

1900

1900

2010

2010

246 840

288 840

288 840

288 840

288 840

288 840

288 840

840

840

840

840

840

840

840

50 950

50 950

50 950

50 950

50 950

50 950

50 950

950

950

950

950

950

950

950

Unit

26

29

29

29

29

29

32

Panel

5.5

5.5

5.5

5.5

5.5

5.5

5.5

H/M/L

35/31/28

38/35/32

38/35/32

45/39/36

45/39/36

47/43/38

48/45/42

Liquid/Gas

9.52/15.88

9.52/15.88

9.52/15.88

9.52/15.88

9.52/15.88

9.52/15.88

9.52/15.88

Unit (HWD)
Dimensions (mm)
Panel (HWD)

Weight (kg)

Noise (dB(A))

Piping (mm)
Drainage

44 | YES Slim & YES Super

DN25

High Wall
Indoor Unit Model

YDHW
022H0NA

YDHW
028H0NA

YDHW
036H0NA

YDHW
056H0NA

YDHW
071H0NA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

2.2

2.8

3.6

5.6

7.1

Heating

2.8

3.2

4.0

6.3

7.15

35

35

40

50

70

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.18

0.18

0.23

0.25

0.35

Air Flow (m3/h)

Standard

450

450

570

730

1050

Dimensions (mm)

HWD

295 890 215

295 890 215

295 890 215

302 1070 220

302 1070 220

Weight (kg)

Net Weight

14

14

14

16

16

Noise (dB(A))

H/M/L

34/30/26

34/30/26

38/35/31

44/41/39

44/41/39

Liquid/Gas

6.35/9.52

6.35/9.52

6.35/12.7

6.35/12.7

9.52/15.88

Piping (mm)
Drainage

DN20

2-way Cassette
Indoor Unit Model

YDDK
028H0PA

YDDK
036H0PA

YDDK
045H0PA

YDDK
056H0PA

YDDK
071H0PA

YDDK
090H0PA

YDDK
112H0PA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

2.8

3.6

4.5

5.6

7.1

9.0

11.2

Heating

3.2

4.0

5.0

6.3

8.0

10.0

12.5

60

62

68

85

94

129

175

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.27

0.28

0.31

0.39

0.43

0.59

0.80

Air Flow (m3/h)

Standard

500

600

770

900

1160

1500

1700

310 840

310 840

310 960

310 960

310 1200

310 1440

310 1440

520

520

520

520

520

520

520

30 1083

30 1083

30 1203

30 1203

30 1443

30 1683

30 1683

630

630

630

630

630

630

630

Unit

41

41

47

47

53

65

65

Panel

H/M/L

34/28/22

35/32/27

38/33/28

40/36/34

42/38/35

42/38/35

46/43/38

Liquid/Gas

6.35/9.52

6.35/12.7

6.35/12.7

6.35/12.7

9.52/15.88

9.52/15.88

9.52/15.88

Unit (HWD)
Dimensions (mm)
Panel (HWD)

Weight (kg)

Noise (dB(A))

Piping (mm)
Drainage

DN25

YES Slim & YES Super | 45

Floor/Ceiling
Indoor Unit Model

YDEC
028H0NA

YDEC
036H0NA

YDEC
045H0NA

YDEC
056H0NA

YDEC
071H0NA

YDEC
080H0NA

YDEC
090H0NA

YDEC
112H0NA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

2.8

3.6

4.5

5.6

7.1

8.0

9.0

11.2

Heating

3.2

4.0

5.0

6.3

8.0

9.0

10.0

12.5

110

110

130

130

180

210

210

210

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.55

0.55

0.65

0.65

0.83

0.97

0.97

1.20

Air Flow (m3/h)

Standard

600

600

950

950

1250

1550

1550

1950

680 1245

680 1245

680 1245

680 1245

680 1245

680 1245

680 1245

680 1670

240

240

240

240

240

240

240

240

36

36

36

36

36

38

38

51

H/M/L

37/33/30

37/33/30

46/44/41

46/44/42

47/45/42

52/48/46

52/48/46

52/48/46

Liquid/Gas

6.35/9.52

6.35/12.7

6.35/12.7

6.35/12.7

9.52/15.88

9.52/15.88

9.52/15.88

9.52/15.88

Dimensions
(mm)
Weight (kg)
Noise (dB(A))

HWD
Net
Weight

Piping (mm)
Drainage

DN25

Floor-concealed
Indoor Unit Model

YDVC
028H0NA

YDVC
045H0NA

YDVC
056H0NA

YDVC
071H0NA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

Cooling

2.8

4.5

5.6

7.1

Heating

3.2

5.0

6.3

8.0

41

50

60

71

Capacity (kW)

Power Input (W)


Current (A)

Nominal

0.18

0.23

0.27

0.32

Air Flow (m3/h)

Standard

420

680

900

1000

Dimensions (mm)

HWD

600 730 230

600 980 230

600 1334 230

600 1334 230

Weight (kg)

Net Weight

20

24

30

31

Noise (dB(A))

H/M/L

35/32/30

35/32/30

36/33/31

37/34/32

Liquid/Gas

6.35/9.52

6.35/12.7

6.35/12.7

9.52/15.88

Piping (mm)
Drainage

DN25

Note:
1.

Cooling conditions: indoor 27CDB/ 19CWB, outdoor 35CDB, equivalent length 10m, IU/OU height difference 0m.

2.

Heating conditions: indoor 20CDB, outdoor 7CDB/6CWB, equivalent length 10m, IU/OU height difference 0m.

3.

Noise data is tested in semi-anechoic chamber and converted to equivalent anechoic chamber data. The actual noise data could vary per different installation and working conditions.

46 | YES Slim & YES Super

Fresh Air Indoor


Indoor Unit Model

YDCF0510
H0NA

YDCF1080
H0NA

YDCF1680
H0NA

YDCF2100
H0NA

YDCF2500
H0NA

Power Supply (V/Ph/Hz)

220/1/50

220/1/50

220/1/50

220/1/50

380/3/50

7.1

14.0

22.4

28.0

28.0

Cooling
Capacity (kW)

Heating

3.5

7.5

10.0

12.0

14.0

Heating*

4.4

9.3

12.8

15.4

18.2

110

250

390

530

740

Power Input (W)


Current (A)

Nominal

0.5

1.1

1.9

2.3

2.0

Air Flow (m3/h)

Standard

510

1080

1680

2100

2500

ESP (Pa)

Standard/High

50/100

100/200

150/220

150/220

150/200/300

Dimensions (mm)

HWD

1105 650 220

820 850 480

1406 850 480

1406 850 480

1406 850 508

Weight (kg)

Net Weight

34

70

110

110

110

Noise (dB(A))

Standard/High

34/40

36/41

43/46

44/47

40/50/51

Liquid/Gas (mm)

9.52/15.88

9.52/15.88

9.52/22.23

9.52/22.23

9.52/22.23

Drainage (mm)

DN25

DN25

DN32

DN32

DN32

Connect to YES outdoor unit (HP)

854

854

854

1054

10

Indoor Unit Model

YDCF3000
H0NE

YDCF3500
H0NE

YDCF4000
H0NE

YDCF5000
H0NE

YDCF6000
H0NE

Power Supply (V/Ph/Hz)

380/3/50

380/3/50

380/3/50

380/3/50

380/3/50

28.0

40.0

45.0

56.0

56.0

Heating

16.0

20.0

21.0

26.0

32.0

Heating*

21.0

26.3

27.6

34.1

42.0

1050

950

1260

1580

2310

Piping

Cooling
Capacity (kW)

Power Input (W)


Current (A)

Nominal

2.3

2.5

2.7

3.6

4.3

Air Flow (m3/h)

Standard

3000

3500

4000

5000

6000

ESP (Pa)

Standard/High

200/300

200/300

200/300

200/300

200/300

Dimensions (mm)

HWD

1406 850 508

1680 850 670

1680 850 670

2000 850 670

2000 850 670

Weight (kg)

Net Weight

110

170

170

210

210

Noise (dB(A))
Piping

Standard/High

51/54

51/54

53/55

54/56

56/57

Liquid/Gas (mm)

9.52/22.23

12.7/25.4

12.7/28.6

15.88/28.6

15.88/28.6

Drainage (mm)

DN32

20

20

Connect to YES outdoor unit (HP)

10

DN40
14

16

Note:
1. Cooling capacity is based on ambient temperature 33C DB, 28C WB.
2. Heating capacity is based on ambient temperature 7C DB, 6C WB; model with open * mark is based on ambient temperature 0C DB, -3C
WB;
3. Cooling default temperature is set as 18C, heating default temperature is set as 25C (0510-2100) or 22C (2500-6000);
4. Outdoor ambient temperature range is -7C46C DB;
5. Models below 2100m3/h can adopt mixed connection with indoor units, but the capacity of fresh air unit cannot be over 30% of the outdoor
capacity;
6. Models below 2100m3/h can adopt multiple connections to YES outdoor unit (all fresh air system), but the capacity ratio should be between
80%100%;
7.

Models over 2500m3/h cannot use multi-connection and mixed connection type. They can only use one-to-one connection to the outdoor unit.

YES Slim & YES Super | 47

Notes

48 | YES Slim & YES Super

Notes

2013 Johnson Controls, Inc.

www. johnsoncontrols.com

PUBL-6969

Anda mungkin juga menyukai