OPERATING PRINCIPLE
Turbine flow sensors measure the flow rate of hydraulic fluid and
compatible liquids. As fluid flows through the sensor it turns the
turbine rotor, and as each turbine blade passes the magnetic pickup
an electrical signal is generated. This frequency signal is proportional
to the flow rate and can be transmitted to Flo-techs digital displays
or converted to a 4-20mA output. Optional sensors allow
measurement of pressure, temperature, and speed.
Rugged construction: Flow sensors are constructed in anodized
aluminum* with SAE, BSPP, Code 61 and Code 62, 4-bolt flanged
ports. The sensor arrays have a forward flow accuracy of +/-1% full
scale, fluid temperature range of -4 to 300F, and are available in
pressure ratings up to 6000 psi.
Bulletin #512
SPECIFICATIONS:
MATERIAL:
Housing: 6013-T651 Anodized aluminum Ball Bearings: 440 C Stainless steel
Adapters: 6061-T6 Anodized aluminum Hub Cones: 6061-T6 Aluminum alloy
Turbine Rotor: T416 Stainless steel
Retainer Rings: 6061-T6 Aluminum alloy
Rotor Supports: 6061-T6 Aluminum;
Seals: Buna N standard; Viton and
C360 Brass for models F6202-A
EPR optional
and F6222-A
Rotor Shaft: T303 Stainless steel
PORTS: SAE J1926/1, BSPP ISO1179
MAGNETIC PICK-UP: Body 12L14 steel, black oxide finish
Lock Nut 12L14 steel, zinc plate, dichromate finish
SIGNAL CONVERTER: Body Nickel-plated 6061-T6 aluminum
Connectors Nickel-plated brass
Electrical:
Circuit Power Requirement: Load + 7.0 mA
Excitation Range: 6 28 VDC
Accuracy: 0.5% of full scale span, plus
Output Current Range: 4 20 mA
accuracy of input source
Minimum Load Resistance: 10 ohms
Thermal Drift: 0.05% F.S. / F
Maximum Load Resistance:
Excitation Voltage 1V
.02
PERFORMANCE:
Forward flow accuracy: 1% of full scale
0.5% of rate when used with XLI display.
Repeatability: 0.2%
Pressure rating: 5800 psi (400 bar) maximum, 5000 psi (345 bar) maximum for
models F6208-A and F6228-A
Pressure drop: See P charts.
Turbine response: < 200 ms
Fluid temperature range: -4 to 300 F (-20 to 150 C)
Ambient temperature range: -4 to 131 F (-20 to 55 C)
BI-DIRECTIONAL FLOW: Optional calibration available
1 Common
2 4-20 mA output
3 +VDC
2
3
DIMENSIONS:
Signal
Converter
SERIES
Magnetic
Pickup
Pressure Port
Adapter
Housing
Temperature
Port Adapter
C
B
WIDTH
in (mm)
LENGTH
in (mm)
HEIGHT
in (mm)
W/MAG
in (mm)
WEIGHT
(lbs)
F6202-A
F6222-A 1.23 (31.2) 4.72 (120.0) 1.47 (37.3) 5.74 (145.6)
1.60
F6204-A
1.48 (37.6) 5.08 (129.0) 1.80 (45.7) 6.04 (153.0)
F6224-A
1.90
2.80
F6208-A
F6228-A 2.46 (62.5) 6.81 (173.0) 2.48 (63.0) 6.74 (171.0)
4.20
3 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S
FLOW RATE
0.4 - 7 GPM
2 - 40 GPM
4 - 80 GPM
8 - 160 GPM
1.5 - 26 LPM
7.5 - 151 LPM
15 - 302 LPM
30 - 605 LPM
MODEL
SEALS
F6202 A
F6204 A
F6206 A
F6208 A
F6222 A
F6224 A
F6226 A
F6228 A
B*
SENSOR PORTS
TEMPERATURE
PRESSURE
N*
S*
*Basic
Model
*Basic Model
The 4-20mA electronics can be set to either sink or source. If the load sink is
specified, the load sensing resistor is connected to the positive side of the excitation
voltage. If load source is specified, the load sensing resistor is connected to the
negative side of the excitation voltage. If ordered as part of a sensor array, the above
specification is sufficient. If not specified, the 4-20mA signal will be current
sourcing, using 600 ohms at 24 VDC.
Seals
B Buna N
V Viton
E EPR
When using Activa Sensor Array with Flo-techs XLI Digital Displays, use F6234-6,
6-ft. or F6234-15, 15-ft. connecting Cables on page 27.
T
N
S
G
D
Temperature
with Sensor
1/4 NPTF (F) Plugged
SAE #2 (J514) Plugged
G 1/4 (F) Plugged
SAE #4
1
3
5
6
N
S
F
Pressure
1000 psi (69 bar) Sensor
3000 psi (207 bar) Sensor
5000 psi (345 bar) Sensor
6000 psi (414 bar) Sensor
1/4 NPTF (F) Plugged
SAE #2 (J514) Plugged
G 1/4 (F) Plugged
100
F6202
F6204
F6206 F6208
F6222
F6224
F6226 F6228
1.0
10
.1
.01
.006
.1
.1
10
FLOW GPM
100
300
.3
10
100
1000
FLOW LPM
Bulletin #513
SPECIFICATIONS:
MATERIAL:
Housing: 6013-T651 Anodized aluminum
Adapters: 6061-T6 Anodized aluminum
Turbine Rotor: T416 Stainless steel
Rotor Supports: 6061-T6 Aluminum; C360 Brass for models F6202-A and F6222-A
Rotor Shaft: T303 Stainless steel
Ball Bearings: 440 C Stainless steel
Hub Cones: 6061-T6 Aluminum alloy
Retainer Rings: 6061-T6 Aluminum alloy
Seals: Buna N standard; Viton and EPR optional
PORTS: SAE J1926/1, BSPP ISO1179
MAGNETIC PICK-UP: Body 12L14 steel, black oxide finish
Nut 12L14 steel, zinc plate, dichromate finish
PERFORMANCE:
Electrical Output Signal: Self-generating alternating pulse, 100 mV RMS (100 Hz) min.
The F6202 / F6222 models have a 10 mV RMS (200 Hz) min.
Forward flow accuracy: 1% of full scale
0.5% of rate when used with XLF display.
Repeatability: 0.2%
Pressure rating: 5800 psi (400 bar) maximum, 5000 psi (345 bar) maximum for
models F6208-F and F6228-F
Pressure drop: See P charts.
Turbine response: < 200 ms
Fluid temperature range: -4 to 300 F (-20 to 150 C)
Ambient temperature range: -4 to 131 F (-20 to 55 C)
BI-DIRECTIONAL FLOW: Optional calibration available
Magnetic Pickup
Pressure Port
Adapter
Temperature
Port Adapter
Housing
D
C
DIMENSIONS:
SERIES
WIDTH
in (mm)
LENGTH
in (mm)
HEIGHT
in (mm)
W/MAG
in (mm)
WEIGHT
(lbs)
F6202-F
F6222-F
1.23 (31.2)
4.72 (120.0)
1.47 (37.3)
3.72 (94.5)
1.55
F6204-F
F6224-F
1.48 (37.6)
5.08 (129.0)
1.80 (45.7)
4.05 (102.9)
1.75
F6206-F
F6226-F
1.98 (50.3)
4.46 (113.3)
2.75
F6208-F
F6228-F
2.46 (62.5)
6.81 (173.0)
4.75 (120.7)
4.10
2.48 (63.0)
5 TEL.1-800-433-5263 V I S I T O U R W E B S I T E F L O - T E C H . C O M
FLOW RATE
0.4 - 7 GPM
2 - 40 GPM
4 - 80 GPM
8 - 160 GPM
1.5 - 26 LPM
7.5 - 151 LPM
15 - 302 LPM
30 - 605 LPM
MODEL
SEALS
F6202 F
F6204 F
F6206 F
F6208 F
F6222 F
F6224 F
F6226 F
F6228 F
B*
N*
S*
*Basic
Model
*Basic Model
**Requires SWI-5, Square Wave Interface (F5130, page 25) to amplify
signal to be compatible with XLF digital display. Connecting cable
part numbers are F2836-6, 6-ft. or F2836-15, 15-ft. on page 27.
Seals
B Buna N
When using Ultima Sensor Array with Flo-techs XLF Digital Displays use
V Viton
F6234-6, 6-ft. or F6234-15, 15-ft. connecting cables on page 27.
E EPR
Five or Ten Point Calibration Certificates are available.
T
N
S
G
D
Flo-tech P.N.
Description
F001109
Five Point Calibration Certificate
F001110
Ten Point Calibration Certificate
These Certificates are traceable to NIST, ISO 9001/ANSI Z540-1
& MIL-STD 45662A
Ordering Example:
F6204 - F B-T6, SAE 16, 2-40 gpm with Buna N seals,
temperature sensor and 6000 psi pressure sensor
SENSOR PORTS
TEMPERATURE
PRESSURE
Temperature
with Sensor
1/4 NPTF (F) Plugged
SAE #2 (J514) Plugged
G 1/4 (F) Plugged
SAE #4
1
3
5
6
N
S
F
Pressure
1000 psi (69 bar) Sensor
3000 psi (207 bar) Sensor
5000 psi (345 bar) Sensor
6000 psi (414 bar) Sensor
1/4 NPTF (F) Plugged
SAE #2 (J514) Plugged
G 1/4 (F) Plugged
( Example ) F6204 F B - T 6
100
F6202
F6204
F6206 F6208
F6222
F6224
F6226 F6228
1.0
10
.1
.01
.006
.1
.1
10
100
300
FLOW GPM
PAGE 13
.3
10
100
1000
FLOW LPM
PRESSURE SENSORS
TEMPERATURE SENSORS
CABLES
PAGE 23
PAGE 26
PAGE 27
SPECIFICATIONS:
MATERIAL:
Housing: FSC, FSB 6013-T651 Anodized aluminum; FSD Stressproof steel,
zinc plated
Turbine Rotor: T416 Stainless Steel
Rotor Supports: FSC-375, 500, 750 Brass C360; FSC-1000, 1005; FSB 6061-T6,
Aluminum alloy; FSD, T303 Stainless steel
Rotor Shaft: FSC, FSB T303 Stainless steel; FSD, Tungsten carbide
Ball Bearings: FSC, FSB 440 C Stainless steel: FSD, Tungsten carbide
Hub Cones: FSC, FSB 6061-T6 Aluminum alloy
Retainer Rings: FSC-375 T303 Stainless steel: FSC-500, 750, 1000, 1005;
FSB, FSD zinc plated steel
Seals: Buna-N, standard; Viton and EPR, optional
PORTS: SAE J1926/1, Code 61 and Code 62: SAE J518
MAGNETIC PICKUP:
For the FSC, FSB, FSD:
Body 12L14 steel, black oxide finish
Nut 12L14 steel, zinc plate, dichromate finish
Fluid Connections
Turbine Flow Measurement
Flow Ranges from 0.4 to 350 GPM
Pressures up to 6000 PSI
Temperatures up to 300 F
Petroleum-based fluids
Classic Turbine Flow Sensors measure the flow
rate of hydraulic fluids and other compatible
liquids. As fluid flows through the sensor it turns
the turbine rotor and as each turbine blade
passes the magnetic pickup an electrical
signal is generated. This frequency signal is
proportional to flow rate and can be transmitted
to Flo-techs XLF digital displays to show gpm,
lpm, rpm and other common units of measure.
FSB
FSC
FSD
D
D
Magnetic Pickup
Magnetic Pickup
Magnetic Pickup
Housing
Housing
Housing
B
B
SERIES
FSC-375*
FSC-500
FSC-750
FSC-1000
FSC-1005
FSB-1250
FSB-1500
FSD-1250
FSD-1500
FSD-2000
MODEL
NUMBER
F2945-ASCM
F2082-ASCM
F2083-ASCM
F2084-ASCM
F2084-ASCM8
F2085-ASBM
F2086-ASBM
F2085-SCDM
F2086-SCDM
F2998-SCDM
A (WIDTH)
1.25 (32)
2.00 (51)
2.00 (51)
2.50 (64)
2.50 (64)
4.00 (102)
4.00 (102)
2.12 (54)
2.50 (64)
3.12 (79)
DIMENSIONS (mm)
B (LENGTH)
C (HEIGHT)
5.00 (127)
1.50 (38)
6.50 (165)
2.00 (51)
6.50 (165)
2.00 (51)
6.50 (165)
2.00 (51)
6.50 (165)
2.00 (51)
7.00 (178)
3.00 (76)
7.00 (178)
3.00 (76)
7.50 (190)
7.50 (190)
8.25 (209)
D (W/MAG)
3.91 (99)
4.16 (106)
4.25 (108)
4.34 (110)
4.34 (110)
4.94 (126)
5.10 (130)
4.50 (114)
4.85 (123)
5.39 (137)
WEIGHT
(LB)
1.25
2.75
2.87
3.25
3.25
7.75
7.40
6.12
6.75
8.55
ORDERING INFORMATION
SERIES
MODEL
NUMBER
NOMINAL
PORT SIZE
FLOW (LPM)
RATE
FSC-375*
FSC-500
FSC-750
FSC-1000
FSC-1005
FSB-1250
FSB-1500
FSD-1250
FSD-1500
FSD-2000
F2945-ASCM
F2082-ASCM
F2083-ASCM
F2084-ASCM
F2084-ASCM8
F2085-ASBM
F2086-ASBM
F2085-SCDM
F2086-SCDM
F2998-SCDM
0.4 - 7 (1.5-26)
1-15 (4-56)
2-25 (7.5-94)
3-60 (11.5-227)
4-85 (15-321)
5-100 (20-378)
7-200 (27-757)
5-100 (20-378)
7-200 (27-757)
10-350 (37-1324)
*Requires SWI-5, square wave interface (F5130, page 25) to amplify signal to be compatible with Flo-techs XLF Digital Display.
When using Classic Turbine Flow Sensors with Flo-techs XLF Digital Displays, use F2832-6, 6-ft. or F2832-15, 15ft. connecting cables, page 27.
Five or Ten Point Calibration Certificates are available.
Flo-tech P.N.
Description
F001109
Five Point Calibration Certificate
F001110
Ten Point Calibration Certificate
These Certificates are traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-STD 45662A
50
FSC-1000
FSC-1005
FSC-500
FSD-1250
10
FSC-750
FSC-1000
FSC-1005
FSB-1500
FSD-1500
FSD-2000
FSB-1250
FSD-1250
FSC-375
PRESSURE DROP BAR
FSC-375
FSB-1500
FSD-1500
FSD-2000
FSB-1250
FSC-500
1
FSC-750
0.1
0.07
1
1
10
100
500
FLOW GPM
PAGE 13
10
100
1000
2000
FLOW LPM
SWI-5 AMPLIFIER
PAGE 25
PAGE 3
CABLES
PAGE 27
SPECIFICATIONS:
MATERIAL:
Housing: FSC, 2024-T351 Anodized aluminum
Turbine Rotor: T416 Stainless Steel
Rotor Supports: FSC Brass C360
Rotor Shaft: FSC T303 Stainless steel
Ball Bearings: FSC 440 C Stainless steel
Hub Cones: FSC 6061-T6 Aluminum alloy
Retainer Rings: FSC zinc plated steel
Seals: Buna-N, standard; Viton and EPR, optional
PORTS: SAE J1926/1, Code 61 and Code 62: SAE J518
MAGNETIC PICKUP:
Body 12L14 steel, black oxide finish
Nut 12L14 steel, zinc plate, dichromate finish
QUAD
Magnetic Pickup (2)
Housing
D
C
SERIES
FSC-2005
FSC-2075
FSC-2100
FSC-2150
MODEL
NUMBER
F2082-ASCQ4
F2083-ASCQ4
F2084-ASCQ4
F2085-ASCQ4
A (WIDTH)
2.00 (51)
2.00 (51)
2.50 (64)
2.50 (64)
B (LENGTH)
6.50 (165)
6.50 (165)
6.50 (165)
6.50 (165)
DIMENSIONS (mm)
C (HEIGHT)
2.00 (51)
2.00 (51)
2.00 (51)
2.00 (51)
D (W/MAG)
4.16 (106)
4.25 (108)
4.34 (110)
4.34 (110)
9 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S
E
4.05 (102)
4.05 (102)
4.59 (117)
4.59 (117)
ORDERING INFORMATION
SERIES
MODEL
NUMBER
NOMINAL
PORT SIZE
FLOW (LPM)
RATE
FSC-500
FSC-750
FSC-1000
FSC-1005
F2082-ASCM
F2083-ASCM
F2084-ASCM
F2084-ASCM8
1-15 (4-60)
2-25 (7.5-94)
3-60 (11.5-227)
4-85 (15-321)
When using Quad Turbine Flow Sensors with Flo-techs XLF Digital Displays, use F2832-6, 6-ft. or F2832-15, 15ft. connecting cables, page 27.
Five or Ten Point Calibration Certificates are available.
Flo-tech P.N.
Description
F001109
Five Point Calibration Certificate
F001110
Ten Point Calibration Certificate
These Certificates are traceable to NIST, ISO 9001/ANSI Z540-1 & MIL-STD 45662A
FSC-2100
FSC-2150
50
FSC-2100
FSC-2150
FSC-2005
FSC-2075
10
FSC-2005
1
FSC-2075
0.1
0.07
1
1
10
100
500
PAGE 13
10
100
1000
2000
FLOW LPM
FLOW GPM
SWI-5 AMPLIFIER
PAGE 25
PAGE 3
CABLES
PAGE 27
Digital Display
Digital Display
Series F6700 (AC) and F6750 (DC) - Accepts standard 4-20 mA or 0-10 VDC analog signal
Applications
Remote flow meter monitoring
Totalizing
Alarm processing
Process control
Features
5-digit rate display
5-digit totalizer with
4-digit overcarry
Dual inputs, 4-20 mA or 0-10 VDC
Built-in transmitter power supply
Three plug-in card slots
Optional setpoint alarm cards
AC and DC powered versions
NEMA 4X / IP65 rated
CE compliant
MAX
MIN
TOT
Inches
( mm )
SP1
DSP
SP2
PAR
F1
SP3
SP4
F2
RST
The F6700/F6750 series digital display with integrated signal processor accepts a 4-20
mA signal from Flo-techs Activa Sensor Array as well as any other 4-20 mA or 0-10 VDC
source. These 5-digit displays can be scaled to most engineering units and are easily
programmed using the front panel buttons or available programming software. To meet your
specific requirements, each display accepts up to three optional plug-in cards. One card for each
of the following function types can be installed in each display:
Analog Outputs A linear DC output signal card will be set up to provide either a 4-20 mA, 0-20
mA or 0-10 VDC signal and can be scaled independent of the input range.
Communications Optional plug-in cards to facilitate digital communications include: RS232,
RS485, Modbus, Profibus and DeviceNet.
Setpoint Alarms Select from dual FORM-C relays (5 Amp), quad FORM-A relays (3 Amp) or
either sinking or sourcing quad open collector logic outputs.
The analog output and communication cards will be installed by the factory at time of order, or
they may be installed by the customer at a later date. The setpoint alarm cards are available for
customer installation and setup only.
SPECIFICATIONS:
Display:
Power:
AC
DC
A/D Converter:
A/D Conversion Rate:
Display Update Rate:
Sensor Inputs:
Transmitter Power:
Totalizer Time Base:
Total:
1.95
(49.5)
Linearization Data
Point Pairs:
Selectable from 2 to 16
Operating Temperature: 32 F to 122 F (0 C to 50 C)
( 32 F to 113 F with all three plug-in cards installed)
Power
0.10
(2.5)
AC
DC
1.75
(44.5)
Display
F6700
F6750
Analog Output
Communications
RS232 A
RS485 B
GPM
LPM
G
L
0-10 VDC C
Modbus C
RPM
None X
Profibus D
psi
None X
4.1
(104.1)
Note: Select one option from each category
Ordering Examples:
F6700-X-X-G = AC powered, displays GPM
F6700-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM
F6750-C-X-B = DC powered + 0-10 VDC Out, displays bars
2
TEL. 1-800-433-5263
Display Units
4-20 mA A
0-20 mA B
DeviceNet E
The F6600/F6650 series rate/counter digital display with integrated signal processor
accepts the frequency signal from Flo-techs Ultima and Classic Turbine Flow Sensors as
well as inputs from a variety of sources including switch contacts, outputs from CMOS or TTL
circuits and magnetic pickups. These meters provide six different display indications, including:
Counter A, Counter B, Counter C (slave display), Rate, Rate Maximum and Rate Minimum.
Annunciators indicate which display is being shown.
Similar to the F6700/F6750 series, these units can be customized to meet individual specificaitons
through the addition of three types of optional plug-in cards: analog outputs, communications
and setpoint alarms. The analog output and communication cards can be installed by the factory
at the time of order, or they may be installed by the customer at a later date. The setpoint alarm
cards are available for customer installation and setup only.
SPECIFICATIONS:
Display:
Rate
Counter
Power:
AC
DC
Sensor Power:
Inputs:
Frequency Range
Trigger Sensitivity
Over Voltage Protected
Operating Temperature:
Ordering Information:
3.80
( 96.5 )
Series F6600 (AC) and F6650 (DC) - Accepts standard frequency signal
bars
B
2
kg/cm
MPa
Display
Analog Output
by Hedland
Communications
Display Units
Inches
( mm )
A
B
C
SP1
DSP
AC
DC
F6600
F6650
4-20 mA A
0-20 mA B
RS232 A
RS485 B
GPM
LPM
G
L
Modbus C
RPM
None X
Profibus D
0-10 VDC
SP2
PAR
F1
SP3
SP4
F2
RST
1.95
(49.5)
3.80
( 96.5 )
0.10
(2.5)
DeviceNet E
None X
1.75
(44.5)
A K-Factor Scaler, F5140, must be used between turbine sensor models FSC-375,
F6202-F, F6222-F and the F6600/F6650 series displays.
Form C Relay Plug-in Option Card - Part Number F6542
This optional plug-in card requires customer installation and setup. To facilitate
setup, it is recommended that this feature be utilized with a display that includes a serial
communication card (RS232 or RS485) and programming software.
Note: For additional setpoint alarm options, consult factory for information.
4.1
(104.1)
Ordering Examples:
F6600-X-X-G = AC powered, displays GPM
F6600-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM
F6650-C-X-G = DC powered + 0-10 VDC Out, displays GPM
Note: For additional setpoint alarm options, consult factory for information.
www.flo-tech.com
Features
6-digit display
Count, rate and slave display
Built-in sensor power supply
Three plug-in card slots
Optional setpoint alarm cards
AC and DC powered versions
NEMA 4X / IP65 rated
CE compliant
Ordering Information:
Power
Applications
Remote flow meter monitoring
Rate comparisons
Alarm processing
Process control
by Hedland
www.flo-tech.com
FAX 1-800-245-3569
Digital Display
Digital Display
Series F6700 (AC) and F6750 (DC) - Accepts standard 4-20 mA or 0-10 VDC analog signal
Applications
Remote flow meter monitoring
Totalizing
Alarm processing
Process control
Features
5-digit rate display
5-digit totalizer with
4-digit overcarry
Dual inputs, 4-20 mA or 0-10 VDC
Built-in transmitter power supply
Three plug-in card slots
Optional setpoint alarm cards
AC and DC powered versions
NEMA 4X / IP65 rated
CE compliant
MAX
MIN
TOT
Inches
( mm )
SP1
DSP
SP2
PAR
F1
SP3
SP4
F2
RST
The F6700/F6750 series digital display with integrated signal processor accepts a 4-20
mA signal from Flo-techs Activa Sensor Array as well as any other 4-20 mA or 0-10 VDC
source. These 5-digit displays can be scaled to most engineering units and are easily
programmed using the front panel buttons or available programming software. To meet your
specific requirements, each display accepts up to three optional plug-in cards. One card for each
of the following function types can be installed in each display:
Analog Outputs A linear DC output signal card will be set up to provide either a 4-20 mA, 0-20
mA or 0-10 VDC signal and can be scaled independent of the input range.
Communications Optional plug-in cards to facilitate digital communications include: RS232,
RS485, Modbus, Profibus and DeviceNet.
Setpoint Alarms Select from dual FORM-C relays (5 Amp), quad FORM-A relays (3 Amp) or
either sinking or sourcing quad open collector logic outputs.
The analog output and communication cards will be installed by the factory at time of order, or
they may be installed by the customer at a later date. The setpoint alarm cards are available for
customer installation and setup only.
SPECIFICATIONS:
Display:
Power:
AC
DC
A/D Converter:
A/D Conversion Rate:
Display Update Rate:
Sensor Inputs:
Transmitter Power:
Totalizer Time Base:
Total:
1.95
(49.5)
Linearization Data
Point Pairs:
Selectable from 2 to 16
Operating Temperature: 32 F to 122 F (0 C to 50 C)
( 32 F to 113 F with all three plug-in cards installed)
Power
0.10
(2.5)
AC
DC
1.75
(44.5)
Display
F6700
F6750
Analog Output
Communications
RS232 A
RS485 B
GPM
LPM
G
L
0-10 VDC C
Modbus C
RPM
None X
Profibus D
psi
None X
4.1
(104.1)
Note: Select one option from each category
Ordering Examples:
F6700-X-X-G = AC powered, displays GPM
F6700-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM
F6750-C-X-B = DC powered + 0-10 VDC Out, displays bars
2
TEL. 1-800-433-5263
Display Units
4-20 mA A
0-20 mA B
DeviceNet E
The F6600/F6650 series rate/counter digital display with integrated signal processor
accepts the frequency signal from Flo-techs Ultima and Classic Turbine Flow Sensors as
well as inputs from a variety of sources including switch contacts, outputs from CMOS or TTL
circuits and magnetic pickups. These meters provide six different display indications, including:
Counter A, Counter B, Counter C (slave display), Rate, Rate Maximum and Rate Minimum.
Annunciators indicate which display is being shown.
Similar to the F6700/F6750 series, these units can be customized to meet individual specificaitons
through the addition of three types of optional plug-in cards: analog outputs, communications
and setpoint alarms. The analog output and communication cards can be installed by the factory
at the time of order, or they may be installed by the customer at a later date. The setpoint alarm
cards are available for customer installation and setup only.
SPECIFICATIONS:
Display:
Rate
Counter
Power:
AC
DC
Sensor Power:
Inputs:
Frequency Range
Trigger Sensitivity
Over Voltage Protected
Operating Temperature:
Ordering Information:
3.80
( 96.5 )
Series F6600 (AC) and F6650 (DC) - Accepts standard frequency signal
bars
B
2
kg/cm
MPa
Display
Analog Output
by Hedland
Communications
Display Units
Inches
( mm )
A
B
C
SP1
DSP
AC
DC
F6600
F6650
4-20 mA A
0-20 mA B
RS232 A
RS485 B
GPM
LPM
G
L
Modbus C
RPM
None X
Profibus D
0-10 VDC
SP2
PAR
F1
SP3
SP4
F2
RST
1.95
(49.5)
3.80
( 96.5 )
0.10
(2.5)
DeviceNet E
None X
1.75
(44.5)
A K-Factor Scaler, F5140, must be used between turbine sensor models FSC-375,
F6202-F, F6222-F and the F6600/F6650 series displays.
Form C Relay Plug-in Option Card - Part Number F6542
This optional plug-in card requires customer installation and setup. To facilitate
setup, it is recommended that this feature be utilized with a display that includes a serial
communication card (RS232 or RS485) and programming software.
Note: For additional setpoint alarm options, consult factory for information.
4.1
(104.1)
Ordering Examples:
F6600-X-X-G = AC powered, displays GPM
F6600-A-A-L = AC powered + 4-20 mA Out + RS232, displays LPM
F6650-C-X-G = DC powered + 0-10 VDC Out, displays GPM
Note: For additional setpoint alarm options, consult factory for information.
www.flo-tech.com
Features
6-digit display
Count, rate and slave display
Built-in sensor power supply
Three plug-in card slots
Optional setpoint alarm cards
AC and DC powered versions
NEMA 4X / IP65 rated
CE compliant
Ordering Information:
Power
Applications
Remote flow meter monitoring
Rate comparisons
Alarm processing
Process control
by Hedland
www.flo-tech.com
FAX 1-800-245-3569
PFM6BD
Flo-check
Bi-Directional
Hydraulic Test Unit
PFM8
Flo-check Digital
Hydraulic Test Unit
& Dynamometer
or metric readings
Large easy-to-use
membrane switch selects
flow, temperature, pressure
or power
Low noise input circuitry
provides steadier readings
when flow is pulsating or
cavitating
Auto/OFF automatically
turns power off after 5
minutes with no flow signal
All-digital, compact, lightweight, selfcontained portable hydraulic tester and
dynamometer. Designed for fast diagnostic
troubleshooting of all types of hydraulic
systems and components, including
engine-pump combinations. Makes
all flow, pressure, temperature and power
measurements simultaneously from
one point, in either U.S. or metric units
(switchable). Silicon strain gauge pressure
sensor. Offers other standard features of
PFM6 model.
DIMENSIONS
SERIES
INCHES
PFM6-15
PFM6-30
PFM6-60
PFM6-85
PFM6-200
PFM6BD-60
PFM6BD-85
PFM6BD-200
PFM8-15
PFM8-30
PFM8-60
PFM8-85
PFM8-200
DIMENSIONS (L x D x H)
LBS (KG)
WEIGHT
LBS (KG)
287 X 279 X 89
287 X 279 X 89
292 X 279 X 89
292 X 279 X 89
311 X 298 X 101
287 X 279 X 101
287 X 279 X 101
300 X 292 X 114
287 X 279 X 89
287 X 279 X 89
292 X 279 X 89
292 X 279 X 89
311 X 298 X 101
13.85 (6.3)
13.85 (6.3)
16.50 (7.5)
16.50 (7.5)
20.00 (9.1)
16.50 (7.5)
16.50 (7.5)
19.50 (9.0)
13.85 (6.3)
13.85 (6.3)
16.50 (7.5)
16.50 (7.5)
20.00 (9.1)
ORDERING INFORMATION
SERIES
MODEL
NUMBER
PFM6-15
F5080 (CE)-XXX
PFM6-30
F5079 (CE)-XXX
PFM6-60
F5078 (CE)-XXX
PFM6-85
F5077 (CE)-XXX
PFM6-200
F5076 (CE)-XXX
PFM6-15
F5110 (CE)-XXX
PFM6-30
F5111 (CE)-XXX
PFM6-60
F5112 (CE)-XXX
PFM6-85
F5113 (CE)-XXX
PFM6-200
F5114 (CE)-XXX
PFM6BD-60 F5082 (CE)-XXX
PFM6BD-85 F5083 (CE)-XXX
PFM6BD-200 F5084 (CE)-XXX
PFM8-15
F5061
PFM8-30
F5058
PFM8-60
F5052
PFM8-85
F5053
PFM8-200
F5054
NOMINAL
PORT SIZE
SAE 12
SAE 12
SAE 16
SAE 16
SAE 24
G 3/4
G 3/4
G1
G1
G 1-1/2
SAE 16
SAE 16
SAE 24
SAE 12
SAE 12
SAE 16
SAE 16
SAE 24
FLOW
RATE
1-15 GPM
2-30 GPM
3-60 GPM
4-85 GPM
7-199.9 GPM
4-56 LPM
7.5-113.6 LPM
12-227 LPM
15-321 LPM
26-757 LPM
3-60 GPM / 12-227 LPM
4-85 GPM / 15-321 LPM
7-199.9 GPM / 26-757 LPM
1-15 GPM / 4-56 LPM
2-30 GPM / 7.5-113.6 LPM
3-60 GPM / 12-227 LPM
4-85 GPM / 15-321 LPM
7-199.9 GPM / 26-757 LPM
POWER
HP (kW)
52.5 (39)
105 (78)
210 (157)
298 (222)
700 (522)
ACCESSORIES
MODEL
NUMBER
F4934-1530
F4934-6085
F4934-200
F1614-6000
F1614-7500
F001109
F001110
NOMINAL
PORT SIZE
Carrying
Cases
Safety Disc
Calibration
Certificates
FLOW
RATE
15 & 30 GPM / 60 & 113.6 LPM
60 & 85 GPM / 200 & 321 LPM
200 GPM / 757 LPM
0-6000 PSI
0-7500 PSI
Five Point
Ten Point
The Sensor Array is used for diagnostic evaluation of hydraulic motors, pumps, valves,
hydrostatic drives and cylinders. When performed as part of a routine preventative
maintenance program, catastrophic or untimely repairs are minimized. All that is
required is to make quick and easy fluid line connections between the sensing array
and appropriate locations in the hydraulic circuit. The load valve is used to create a
restriction so that a relief valve setting or internal leakage of a valve or hydraulic
cylinder can be determined. The efficiency of a hydraulic pump or motor can be
similarly established and compared to factory specifications.
F6100 series sensor arrays are turbine flow meters equipped with auxiliary pressure
and temperature sensors and an internal loading valve. The sensor arrays measure
flow, pressure, and temperature simultaneously. Each sensor has a self-contained
conditioning circuit that converts raw sensor input to a 4-20 mA output signal suitable
for use with Flo-techs SIM-Check system analyzers and XLI and XLF readouts. They
are also suitable for use with data loggers, strip chart recorders, and control/monitoring
devices such as PCs and PLCs. An optional pulse output for flow measurement is
also available.
SPECIFICATIONS:
MATERIAL:
Housing: 2024-T351 Anodized aluminum
Turbine Rotor: T416 Stainless steel
Rotor Supports: 6061-T6 Aluminum
Rotor Shaft: T303 Stainless steel
Seals: Buna N standard; Viton and EPR optional
Ball Bearings: 440 C Stainless steel
Hub Cones: 6061-T6 Aluminum alloy
Temperature Probe: 12L14 Steel
F6100 SERIES SENSORS
Valve Body for 15/30s: cold rolled steel; 60/85/200 Body:12L14 Steel Stem
303 Stainless steel
Poppet: 12L14 Steel, Hardened
Straightening section: for 15/30 (60/113.5 GPM) is CA360 Brass;
for 60/85/200 (199.9/350/750 LPM) is 6061-T6 Aluminum
Cones: 2024-T4 Aluminum
200 GPM: Sleeve D.O.M. steel tube
PORTS: SAE Straight Thread O-RingBoss, Female, J1926/1;
BSPP ISO1179
MAGNETIC PICK-UP: Body 12L14 steel, black oxide finish;
Nut 12L14 steel, zinc plate, dichromate finish
PERFORMANCE:
Electrical Output Signal: Self-generating alternating pulse, 100 mV RMS (100 Hz) min.
Flow accuracy: 1% of full scale
Repeatability: 0.2%
Pressure rating: 6000 psi (414 bar) maximum
Turbine response: 200 MS
Fluid temperature range: -4 to 300 F (-20 to 150 C)
Ambient temperature range: -4 to 131 F (-20 to 55 C)
For pressure drop information, refer to page 22.
17 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S
MODEL
NUMBER
F6150
F6153
F6156
F6159
F6161
F6163
F6165
F6167
FLOW RATE
1 - 15 GPM
2 - 30 GPM
4 - 85 GPM
7 - 199.9 GPM
4 - 56 LPM
7.5 - 113.6 LPM
15 - 321 LPM
26 - 757 LPM
Ordering Example:
F6154-AB-T6, SAE #16, 3-60 GPM with
4-20 mA flow transducer, 4-20 mA
temperature transducer & 6000 psi pressure
sensor with 4-20 mA electrical output.
FLOW
TRANSDUCER
SEALS
Flow
Seals
Transducer
B Buna N
A 4-20 mA Output V Viton
F Frequency Output E EPR
F6150-AB-T1
F6150-AB-T3
F6150-AB-T6
F6153-AB-T1
F6153-AB-T3
F6153-AB-T6
F6156-AB-T1
F6156-AB-T3
F6156-AB-T6
F6159-AB-T1
F6159-AB-T3
F6159-AB-T6
F6161-AB-T1
F6161-AB-T3
F6161-AB-T3
F6163-AB-T1
F6163-AB-T3
F6163-AB-T6
F6165-AB-T1
F6165-AB-T3
F6165-AB-T6
F6167-AB-T1
F6167-AB-T3
F6167-AB-T6
F6162
F6233
F1614-6000
F1614-7500
ITEM
DESCRIPTION
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Turbine-type Flow Block with Active Magnetic (Flow)
Transducer, Active Pressure Transducer and
Active Temperature Sensor
Cable, Sensor Array (with 3 Female Connectors) 30 ft.
Cable Auxiliary (with single Female Connector) 30 ft.
Safety Disc, 6000 PSI
Safety Disc, 7500 PSI
Temperature
Transducer Output:
4-20 mA
T with Sensor
G G 1/4 (F) Plugged
O SAE #2 (J514) Plugged
1
3
6
G
O
Pressure Transducer
Output: 4-20 mA
1000 psi (69 bar) Sensor
3000 psi (207 bar) Sensor
6000 psi (414 bar) Sensor
G 1/4 (F) Plugged
1/4 NPTF (J514) Plugged
( Example ) F6154 A B - T 6
ACTIVA AUXILIARY
PRESSURE SENSORS WITH 4-20mA
SENSOR PORTS
TEMPERATURE
PRESSURE
PORTS
FLOW
PRESSURE
SAE 12
SAE 12
SAE 12
SAE 12
SAE 12
SAE 12
SAE 16
SAE 16
SAE 16
SAE 24
SAE 24
SAE 24
G 3/4
G 3/4
G 3/4
G 3/4
G 3/4
G 3/4
G1
G1
G1
G 1-1/2
G 1-1/2
G 1-1/2
1-15 GPM
1-15 GPM
1-15 GPM
2-30 GPM
2-30 GPM
2-30 GPM
4-85 GPM
4-85 GPM
4-85 GPM
7-199.9 GPM
7-199.9 GPM
7-199.9 GPM
4-56 LPM
4-56 LPM
4-56 LPM
7.5-113.6 LPM
7.5-113.6 LPM
7.5-113.6 LPM
15-321 LPM
15-321 LPM
15-321 LPM
26-757 LPM
26-757 LPM
26-757 LPM
0-1K PSI
0-3K PSI
0-6K PSI
0-1K PSI
0-3K PSI
0-6K PSI
0-1K PSI
0-3K PSI
0-6K PSI
0-1K PSI
0-3K PSI
0-6K PSI
0-69 BAR
0-207 BAR
0-414 BAR
0-69 BAR
0-207 BAR
0-414 BAR
0-69 BAR
0-207 BAR
0-414 BAR
0-69 BAR
0-207 BAR
0-414 BAR
PART
NUMBER
F6301-15
F6301-30
F6301-60
F6301-100
F6301-150
F6301-200
F6301-300
F6301-500
PRESSURE
PSI
BAR
0-15
0-30
0-60
0-100
0-150
0-199
0-300
0-500
0-1.035
0-2.07
0-4.14
0-6.9
0-10.35
0-13.80
0-20.70
0-34.5
PORTS
PART
NUMBER
1/4
NPT
Male
F6301-750
F6301-1K
F6301-2K
F6301-3K
F6301-5K
F6301-7.5K
F6301-10K
F6301-15K
PRESSURE
PSI
BAR
0-750
0-1000
0-2000
0-3000
0-5000
0-7500
0-10,000
0-15,000
0-51.75
0-69
0-138
0-207
0-345
0-517.5
0-690
0-1035
PORTS
1/4
NPT
Male
ITEM DESCRIPTION
Temperature Sensor, -40 to 350 F, Thread-5/16-24 UNF-2B, suitable for
SAE J1926-2 O-Ring Boss (SAE #2)
Cable, Auxiliary (with Female Connector) 30 ft.
F6100Pressure
& PFM
Series
Drop Information
FLOW VS PRESSURE DROP
120
100
100
80
80
PSI
PSI
60
60
PFM6-15
F6150
F6161
PFM6-30
F6153
F6163
40
40
20
20
10
GPM
15
20
10
20
GPM
40
120
100
100
80
80
PSI
PSI
30
60
60
PFM6-85
F6156
F6165
PFM6-60
40
40
20
20
0
0
20
10
30
40
50
60
70
10
20
30
40
GPM
50
60
70
80
90
100
GPM
80
PSI
PSI
140
60
PFM6-200
F6159
F6167
120
FORWARD
100
REVERSE
80
40
60
40
20
20
0
0
0
20
40
60
80
100
120
GPM
140
160
180
200
220
10
20
30
40
50
60
70
GPM
120
150
135
100
120
105
80
PSI
PSI
90
FORWARD
60
FORWARD
75
REVERSE
REVERSE
60
40
45
30
20
15
0
0
0
10
20
30
40
50
GPM
60
70
80
90
100
10 20 30 40 50 60 70 80 90 100 110 120 130 140 150 160 170 180 190 200 210 220
GPM
F6301
Pressure
Sensor
With 4-20 mA Output
Bulletin #514
SPECIFICATIONS:
OVERPRESSURE: Full scale in PSI
0-15 to
0-3000 to
0-7500 to
0-2000
0-5000
0-15,000
Proof
200%
150%
120%
Burst
800%
300%
150%
ACCURACY: 1% of full scale
Non-Linearity: 0.7%
Hysteresis: 0.2%
Non-repeatability: 0.07%
DURABILITY: 10 8 cycles 20/80% full scale with negligible performance change
RESPONSE TIME: < 5ms
ENVIRONMENTAL EFFECTS:
Humidity: No performance effect at 95% relative humidity-noncondensing
Position Effect: < 0.01% full scale
TEMPERATURE:
Storage: -65 to +250 F (-54 to 121 C)
Operating: -20 to +180 F (-29 to 82 C)
Compensating: -20 to +160 F (-29 to 71 C)
PRESSURE RANGES
Part No.
F6301-15
F6301-30
F6301-60
F6301-100
F6301-150
F6301-200
F6301-300
F6301-500
F6301-750
F6301-1K
F6301-2K
F6301-3K
F6301-5K
F6301-6K
F6301-7.5K
F6301-10K
F6301-15K
PSI
0 - 15.00
0 - 30.0
0 - 60.0
0 - 100.0
0 - 150.0
0 - 200
0 - 300
0 - 500
0 - 750
0 - 1000
0 - 2000
0 - 3000
0 - 5000
0 - 6000
0 - 7500
0 - 10,000
0 - 15,000
BAR
0 - 1.034
0 - 1.999
0 - 4.13
0 - 6.89
0 - 10.34
0 - 13.78
0 - 19.99
0 - 34.5
0 - 51.7
0 - 68.9
0 - 137.8
0 - 199.9
0 - 345
0 - 414
0 - 517
0 - 689
0 - 1034
23 TEL.1-800-433-5263 L E A R N A B O U T O U R C A L I B R AT I O N S E R V I C E S
kg/cm2
0 - 1.055
0 - 1.999
0 - 4.22
0 - 7.03
0 - 10.55
0 - 14.06
0 - 19.99
0 - 35.1
0 - 52.7
0 - 70.3
0 - 140.6
0 - 199.9
0 - 351
0 - 422
0 - 527
0 - 703
0 - 1055
Ports
1/4
NPT
Male
F6301 Pressure
Sensor
With 4-20 mA Output
SPECIFICATIONS (cont.):
THERMAL COEFFICIENTS (68 F ref.) % full scale / F
Standard:
Zero: 0.04%
Span: 0.04%
VIBRATION SWEEP: < 0.1% full-scale effect for 0-2000 Hz at
20 gs in any axis
SHOCK: < 0.5% full-scale effect for 100 gs, 20 ms shock in any axis
ELECTRICAL:
Output Signal: 4-20 mA (2 wire)
Load Limitations 4-20mA Output Only
(R LOOP)
1182
1000
750
500
250
0
0
10
20
30
36
2.70"
(69mm)
.85"
(22mm)
2
3
1 - N/C
2 - SIGNAL OUTPUT
3 - +VDC
5/8" Hex
4.00"
(102mm)
TEMPERATURE SENSORS
CABLES
PAGE 11
3
PAGE 21
26
PAGE 34
27
PAGE 32
K-Factor Scaler
Frequency Divider
SPECIFICATIONS
External Power:
Input Voltage
Maximum
Current Draw
Inputs:
Magnetic pick-up
Frequency Range 0-4000 Hz
Trigger Sensitivity 30 mV p-p to 30 V p-p
Output Signal:
Internal Pull-up
Resistor:
Operating
Temperature:
Enclosure:
ORDERING INFORMATION
MODEL
PART NUMBER
K-Factor Scaler
F5140
F5141
Fax 800-245-3569
25
F6310
Temperature Sensors
With 4-20 mA Output
Bulletin #515
SPECIFICATIONS:
TEMPERATURE RANGE:
Ambient: -40 to +350 F (-40 to +177 C)
Fluid: -4 to +350 F (-20 to +177 C)
Dedicated Input and Span Range: -40 to +350 F (-40 to +177 C)
ACCURACY: Chart A
CURRENT SPAN RANGE: 4-20 mA
RESPONSE TIME: 3 seconds
MAXIMUM PRESSURE: 6000 PSI (414 Bar, 422 kg/cm2)
OPERATING LOOP VOLTAGE:
Minimum: 9V + Voltage of load resistor at 20 mA
Maximum: 28V
Minimum Load Resistance: 10 ohms
Maximum Load Resistance: Loop Voltage 9V
Ohms
(including wiring losses)
20 mA
Compatible with Flo-tech XLI Digital display (page 11) and connecting cable,
F6234-15, 15-ft. cable (page 27)
CHART A
Combined
Celsius
Celsius/Fahrenheit
Only
Temperature
Accuracy Temp. Accuracy
-40 C -40 F 0.8 C -40 C 0.8 C
0 C +32 F 0.6 C
0 C 0.6 C
+100 C +212 F 1.2 C +50 C 0.9 C
+176 C +350 F 1.7 C +100 C 1.2 C
+150 C 1.5 C
+176 C 1.7 C
Fahrenheit
Only
Temp. Accuracy
-40 F 1.4 F
0 F 1.2 F
+50 F 1.2 F
+100 F 1.5 F
+200 F 2.1 F
+300 F 2.7 F
+350 F 3.0 F
.85"
(22mm)
5/16-24 UNF-2B
Suitable for
SAE J1926-2
O-Ring Boss
(SAE #2)
2.81"
(72mm)
3.41"
(87mm)
Pin Configuration
1 Case Ground
2 Signal
3 + Voltage
0.25" (6.4mm)
PAGE 3
PRESSURE SENSORS
CABLES
PAGE 23
PAGE 11
PAGE 27
Cables
Flo-tech offers a complete selection of mating cables to
complete your hydraulic measurement system.
To select the appropriate cable for your application, refer
to the Connecting Cable Charts shown below and on the
next page.
Connecting Cable
Connecting Ends
Signal
Amplifier
Digital Display
F2832-6, 6 ft or
F2832-15, 15 ft
MS female to
tinned leads
F5140
K-Factor Scaler
F2832-6, 6 ft or
F2832-15, 15 ft
F6234-6, 6 ft or
F6234-15, 15 ft
3-Pin female to
tinned leads
F5140
K-Factor Scaler
F6234-6, 6 ft or
F6234-15, 15 ft
3-Pin female to
tinned leads
F6557-6, 6 ft or
F6557-15, 15 ft
5-Pin female to
tinned leads
F6557-6, 6 ft or
F6557-15, 15 ft
5-Pin female to
tinned leads
F6301-X
(Pressure Sensors)
F6234-6, 6 ft or
F6234-15, 15 ft
3-Pin female to
tinned leads
F6310
(Temperature Sensor)
F6234-6, 6 ft or
F6234-15, 15 ft
3-Pin female to
tinned leads
Sensor Model
FSC-375
FREQUENCY
FSC-500
FSC-750
FSC-1000
FSC-1005
FSB-1250
FSB-1500
FSD-1250
FSD-1500
FSD-2000
F6202-F / F6222-F
F6204-F / F6224-F
F6206-F / F6226-F
F6208-F / F6228-F
FSC-375 with IFC
FSC-500 with IFC
FSC-750 with IFC
FSC-1000 with IFC
FSC-1005 with IFC
FSB-1250 with IFC
ANALOG
28
Tel 800-433-5263
Common Conversions
To Convert
Barrel (U.S. liquid)
Bars
Bars
Centigrade
Cubic centimeters
Cubic centimeters
Cubic centimeters
Cubic centimeters
Cubic centimeters
Cubic feet
Cubic feet
Cubic feet
Cubic feet
Cubic feet
Cubic feet
Cubic feet/min
Cubic feet/min
Cubic feet/min
Cubic feet/sec
Cubic inches
Cubic inches
Cubic inches
Cubic inches
Cubic inches
Cubic inches
Cubic meters
Cubic meters
Cubic meters
Cubic meters
Cubic meters
Degree Fahrenheit
Feet/min
Into
Gallons
Kgs/sq meter
Pounds/sq in
Fahrenheit
Cu feet
Cu inches
Cu meters
Gallons (U.S. liquid)
Liters
Cu cms
Cu inches
Cu meters
Gallons (U.S. liquid)
Imperial gallons
Liters
Cu cms/min
Gallons/min
Liters/min
Gallons/min
Cu cms
Cu feet
Cu meters
Gallons (U.S. liquid)
Imperial gallons
Liters
Cu cms
Cu feet
Cu inches
Gallons (U.S. liquid)
Liters
Degree Celsius
Cms/sec
Multiply by
31.5
10,200
14.50
(C x 9.5) +32
.00003521
0.06102
.000001
.0002642
0.001
28,320
1,728
0.02832
7.48052
6.23210
28.317
28,317
7.481
28.32
448.83
16.39
.0005787
.00001639
.004329
.0036065
0.01639
1,000,000
35.31
61,023
264.2
1,000
t C = (t F 32)/1.8
0.5080
To Convert
Feet/min
Gallons/min
Gallons/min
Gallons/min
Imperial gallons
Imperial gallons
Imperial gallons
Imperial gallons
Kilograms/sq cm
Kilograms/sq cm
Kilograms/sq meter
Kilograms/sq meter
Liters
Liters
Liters
Liters
Liters
Liters
Liters/min
Liters/min
Liters/min
Pascal (Pa)
Pascal (Pa)
Pounds/sq inch
Pounds/sq inch
Pounds/sq inch
U.S. gallons
U.S. gallons
U.S. gallons
U.S. gallons
U.S. gallons
U.S. gallons
Into
Meters/min
Cu cms/min
Cu feet/min
Liters/min
Cu feet
Cu inches
Liters
U.S. gallons
Pounds/sq ft
Pounds/sq in
Bars
Pounds/sq in
Cu cm
Cu feet
Cu inches
Cu meters
Gallons (U.S. liquid)
Imperial gallons
Cu cms/min
Cu feet/min
Gallons/min
Bar
Pounds/sq in
Kgs/sq meter
Pascal (Pa)
Bar
Imperial gallons
Cu cms
Cu feet
Cu inches
Cu meters
Liters
Multiply by
0.3048
3,785.412
.1337
3.785
.160459
277.274
4.54374
1.20032
2,048
14.22
.00009807
.001422
1,000
0.0353145
61.0234
0.001
0.264170
.220083
1000
.035
.264
.00001
.000145
703.1
6,895
.069
.83267
3785
.133681
231
.3785
3.785
40
5
4.2
3.68
45
5/7
5.9
5.17
50
7
7.5
6.57
Kerosene
55
7/10
8.8
7.71
Atlantic Richfield/Duro 55 Hyd. Oil
60
10
10.5
9.20
Monsanto/Skydrol - 500 A
70
10/15
13.2
11.56
Mobil/Aero HFA Hydraulic Oil
80
15
15.7
13.75
No 4 Fuel Oil
90
22
18.2
15.94
Stauffer Chemical/Fyrquel 90
100
22
20.6
18.05
Conoco/Syncon Synthetic AW Hyd. Oil
150
32
32.0
28.03
Mobile/DTE 24 Hydraulic Oil
200
46
43.2
37.84
Citco/Glycol FR-40XD (Oil in Water)
300
68
65.0
56.94
SAE 20 Crankcase Oil
400
68/100
86.0
75.34
Sunoco/Sunvis 41 Hydraulic Oil
500
100
108
94.61
SAE 30 Crankcase Oil
750
150
162
141.91
SAE 40 Crankcase Oil
1000
220
216
189.22
Mobil/Paper Machine Oil - Type K
1500
320
323
282.95
SAE 50 Crankcase Oil
2000
460
431
377.56
Amoco/American Industrial Oil - No. 460
3000
680
648
567.65
SAE 140 Gear Oil
4000
1000
862
755.11
SAE 250 Gear Oil
* Centipoise are given for oil of 0.876 specific gravity. Relationship: centistokes X specific gravity = centipoise
Notes
Flo-tech
by
30
Flo-tech
by
MAILING ADDRESS
P.O. BOX 1405
RACINE, WI 53401
SHIPPING ADDRESS
2200 SOUTH STREET
RACINE, WI 53404
TELEPHONE:
(262) 639-6770
FAX:
(262) 639-2267
DISTRIBUTED BY: