Anda di halaman 1dari 13

APPENDIX A - MOTOR DATA SHEETS

JOB NO.

INDUCTION MOTOR
API 547 1st Edition -- DATA SHEETS
U.S. CUSTOMARY UNITS

ITEM / TAG NO.

PURCHASE ORDER NO.


REQ. / SPEC. NO.
REVISION NO.

DATE
PAGE

FOR/USER

DRIVEN EQUIPMENT

SITE/LOCATION

QUANTITY

SUPPLIER

SUPPLIER PROJECT NO.

Applicable To:

Proposal

NOTE:
(Excel code)

TO BE COMPLETED BY
PURCHASER (m or l)

Purchase

As-built

BY MANUFACTURER
WITH PROPOSAL (o or n)

BY MANUFACTURER
AFTER ORDER (s or q)

BY MANUFACT
PURCHASER (

MOTOR BASIC DATA


6

Applicable Standards (1.4.2):

Nameplate Rating (1.1):

hp

8
9

Motor Power Source:

11

Ambient Temperature

12

Motor Location:

14

Mounting:

15

Other:

Dust

Area Classification:

m
Connection to load:

19

Sound Pressure Level (2.1.2):

20

Enclosure (2.4.1.1):

Bearings (2.4.7):

23

Main Terminal Box (3.1.1):

27
28
29

Site Elevation:

Outdoor

m
m

Outdoor with roof

Chemicals

Foot Mounted

Flange Mounted

m
m

Group

Offshore
Corrosive Agents

Flange details

Division

or

Zone

Autoignition Temp

Other:

Weather-protected Type II (WPII) (2.4.1.3)

HYDRODYNAMIC (2.4.7.1.1)

WPII AIR FILTERS (2.4.1.3.f)

Pressure switch

NEMA MG 1 PART 20 TYPE II


Conductor Size

Space Heaters (3.1.5.f):

Temp. Code

T3C

Qty. Per Phase


or

mT

Type/Insulation

Volts:

Cable Entry:

Phase:

ACROSS-THE-LINE STARTING AT 80% OF RATED VOLTAGE

Unloaded

Other Starting Method

Partially Loaded

Type

Reduced Voltage

30
ACCESSORIES:
31

32

Winding Temperature Detectors (3.2):

34
35

m
o

37

39
40

Temp. Code

or

T3C

mT

Volts:

Phase:

PLATINUM, 3 WIRE, 100 Ohms at 0C, 2 per PHASE

Stator RTD Box Location:


Recommended Settings:

Alarm

Hydrodynamic Bearing Temperature Detectors (3.3):

36

38

Motor space heaters (3.4):

m
o

Recommended Settings:

Alarm

Vibration Probes (Option, 2.4.5.1.2, per API 541)

Shutdown

PLATINUM, 3 WIRE, 100 Ohms at 0C

Bearing Temperature Sensor Wire Terminations:

Additional Information:

Other:

Antifriction (2.4.7.1.6)

Additional Information:

33

LESS THAN 3300 FT

TEFC (2.4.1.2)

Box Location

Loaded

ASD power (1.3.e, 2.2.1. Purchaser to advise details, see Page 2, lines 7 through 11)

LESS THAN 85 dBA @ 3 ft, NO-LOAD, FULL VOLT/FREQ., SINE WAVE POWER

Motor Starting (2.2.2.3)

m
m

Hertz

Other:

Nonclassified

m
m

22

26

Phase

DIRECT COUPLED

21

m
m

m
Class

18

25

m
m

Indoor

HORIZONTAL

17

24

-25 to +40 C

m
m

13

SINE WAVE POWER

Usual Service Conditions (1.2.a, b, c, d, e, h):

International (i.e., IEC, ISO)

RPM (Synchronous)

Volts (2.2.1)

10

16

NORTH AMERICAN (i.e., ANSI, NEMA)

Terminal box at motor side

C
Details:

Shutdown

In the Stator RTD T Box


C

BY
1

OF

BY MANUFACTURER OR
PURCHASER (w or u)

MOTOR BASIC DATA

ASD power (1.3.e, 2.2.1. Purchaser to advise details, see Page 2, lines 7 through 11)

Other:

Pressure gauge

Cable Entry:

kW

Volts

ACCESSORIES:

kW

Conduit Head at Bearing

tg

JOB NO.

INDUCTION MOTOR
API 547 1st Edition -- DATA SHEETS
U.S. CUSTOMARY UNITS

ITEM / TAG NO.

PURCHASE ORDER NO.


REQ. / SPEC. NO.
REVISION NO.

DATE
PAGE

NOTE:
(Excel code)

TO BE COMPLETED BY
PURCHASER (m or l)

BY MANUFACTURER
WITH PROPOSAL (o or n)

BY MANUFACTURER
AFTER ORDER (s or q)

BY MANUFACT
PURCHASER (

MISCELLANEOUS:
2

Auxillary nameplate(s) with purchaser information (2.4.11.4):

3
4

Details:
Additional Information:

5
SPECIAL CONDITIONS:
6
7
8
9
10
11

Adjustable Speed Drive Operation (1.3.e, 2.2.1):

m
m
m
m

ASD only

ASD with DOL Start

Bypass @ Utility Frequency

Variable Torque Speed Range:

Min Speed

RPM

Constant Torque Speed Range:

Min Speed

Constant Power Speed Range:

Min Speed

ft-lb.

Max. Speed

RPM

RPM

Max. Speed

RPM

RPM

Max. Speed

RPM

Other Unusual Service Conditions (1.3):

12
DRIVEN EQUIPMENT INFORMATION
13

Driven Equipment:

14

Type of Load:

15

Total Driven-equipment WK2 (2.2.2.5)

16

Rotation Viewed from Opposite Drive End of Motor:

17

Coupling (2.4.9.2):

18

Supplied By:

19

Mounted By:

20

Tag No.

Centrifugal Compressor

Description

Pump

Fan

Manufacturer:

lb.-ft2 at

Type

Location
Type/Model No.
RPM

Load Speed-torque Curve No. (2.2.2.5)

Clockwise

Counterclockwise

Mfr.

m
m

Motor Mfr
Motor Mfr

m
m

Driven Equipment Mfr


Driven Equipment Mfr

Bi-directional
Type/Model

m
m

Purchaser
Purchaser

m
m

Others
Others

Other:
ANALYSIS, SHOP INSPECTION, AND TESTS

21

Routine Test (4.1.2)

22

No load current

23

Locked rotor current

24

High-potential test (stator, heaters, RTDs)

25

Insulation resistance test

26

Stator resistance

27

Vibration measurement

28

Bearing insulation test

29

Bearing temperature rise

30

Stator Surge Test (4.1.4)

31

Special Tests (per API 541 as noted)

32

Complete Test (541 Para 4.3.5.1)

33

Unbalance Response (541 Para 4.3.5.3)

34

Rated Rotor Temperature Vibration Test (541 Para 4.3.5.2)

35

Sealed Winding Conformance Test (541 Para 4.3.4.4)

36

Other

37

Other

Required

Observed

m
m
m
m
m
m
m
m
m

m
m
m
m
m
m
m
m
m

m
m
m
m
m
m

m
m
m
m
m
m

BY
2

OF

BY MANUFACTURER OR
PURCHASER (w or u)

MISCELLANEOUS:

SPECIAL CONDITIONS:

RPM

ft-lb.

RPM

ft-lb.

RPM

HP

VEN EQUIPMENT INFORMATION

RPM

Bi-directional

IS, SHOP INSPECTION, AND TESTS


Witnessed

m
m
m
m
m
m
m
m
m
m
m
m
m
m
m
m

JOB NO.

INDUCTION MOTOR
API 547 1st Edition -- DATA SHEETS
U.S. CUSTOMARY UNITS

ITEM / TAG NO.

PURCHASE ORDER NO.


REQ. / SPEC. NO.
REVISION NO.

DATE
PAGE

NOTE:
(Excel code)

TO BE COMPLETED BY PURCHASER
(m or l)

BY MANUFACTURER
WITH PROPOSAL (o or n)

BY MANUFACTURER
AFTER ORDER (s or q)

BY MANUFACTU
PURCHASER (w

MOTOR DATA
2

Manufacturer

Type/Model No.

Qty.

Service Factor

Full-load Speed

Locked-rotor Torque (LRT)

Load Point

Efficiency

hp
1.

###
###

RPM (Syn.)
Insulation Class

RPM

Poles

CLASS F

Volts

Temperature Rise

Full-load Torque (FLT)


% FLT

50%

ft-lb.

Pull-up Torque (PUT)

75%

Frame Size/Designation

100%

CLASS B

Breakdown Torque (BDT)

Guar. Efficiency at

Power Factor

10

Current

Amps

Amps

Amps

Amps

11

Speed-torque Curve No.

12

Voltage Magnitude

13

Locked-rotor Current

Amps

Amps

Locked-rotor PF

14

Locked-rotor Withstand Time, Cold

Sec.

Sec.

Sound Pressure Level (2.1.2)

15

Locked-rotor Withstand Time, Rated Temp

Sec.

Sec.

16

Weights:

17

Other:

Net

Speed-current Curve No.


100%

lb.

Stator

19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

Test Method:

Speed-power Factor Curve No.

Other:

lb.

COMMENTS
18

Enclosure

Rotor WK2
% FLT

Other:

Rotor

lb.

Shipping

BY
3

OF

BY MANUFACTURER OR
PURCHASER (w or u)

MOTOR DATA

Phase

Hz

Enclosure
lb.-ft2
% FLT

% Load =

dBA @ 3', no-load

lb.

COMMENTS

JOB NO.

INDUCTION MOTOR
API 547 1st Edition -- DATA SHEETS
METRIC UNITS

ITEM / TAG NO.

PURCHASE ORDER NO.


REQ. / SPEC. NO.
REVISION NO.

DATE
PAGE

FOR / USER

DRIVEN EQUIPMENT

SITE / LOCATION

QUANTITY

SUPPLIER

SUPPLIER PROJECT NO.

Applicable To:

Proposal

NOTE:
(Excel code)

TO BE COMPLETED BY PURCHASER
(m or l)

Applicable Standards (1.4.2):

Nameplate Rating (1.1):

Purchase

As-built

BY MANUFACTURER
WITH PROPOSAL (o or n)

BY MANUFACTURER
AFTER ORDER (s or q)

BY MANUFACT
PURCHASER (

MOTOR BASIC DATA

kW

8
9

Motor Power Source:

11

Ambient Temperature

12

Motor Location:

14

Mounting:

15

Other:

Dust

Area Classification:

m
Connection to load:

19

Sound Pressure Level (2.1.2):

20

Enclosure (2.4.1.1):

Bearings (2.4.7):

23

Main Terminal Box (3.1.1):

27
28
29

Foot Mounted

Flange Mounted

m
m

Group

Offshore
Corrosive Agents

Flange details

Zone

Autoignition Temp

Other:

Weather-protected Type II (WPII) (2.4.1.3)

HYDRODYNAMIC (2.4.7.1.1)

WPII AIR FILTERS (2.4.1.3.f)

Pressure switch

Antifriction (2.4.7.1.6)

NEMA MG 1 PART 20 TYPE II


Conductor Size

Space Heaters (3.1.5.f):

Temp. Code

T3C

Qty. Per Phase


or

mT

Type/Insulation

Volts:

Cable Entry:

Phase:

ACROSS-THE-LINE STARTING AT 80% OF RATED VOLTAGE

Unloaded

Other Starting Method

Partially Loaded

Type

Reduced Voltage

Additional Information:

30
ACCESSORIES:
31

32

Winding Temperature Detectors (3.2):

34
35

m
o

37

39
40

Temp. Code

or

T3C

mT

Volts:

Phase:

PLATINUM, 3 WIRE, 100 Ohms at 0C, 2 per PHASE

Stator RTD Box Location:


Recommended Settings:

Alarm

Hydrodynamic Bearing Temperature Detectors (3.3):

36

38

Motor space heaters (3.4):

m
o

33

Recommended Settings:

Alarm

Vibration Probes (Option, 2.4.5.1.2, per API 541)

Shutdown

PLATINUM, 3 WIRE, 100 Ohms at 0C

Bearing Temperature Sensor Wire Terminations:

Additional Information:

Other:

TEFC (2.4.1.2)

Box Location

Loaded

m
m

Outdoor with roof

Chemicals

LESS THAN 1000 m

LESS THAN 85 dBA @ 1 m, NO-LOAD, FULL VOLT/FREQ., SINE WAVE POWER

Motor Starting (2.2.2.3)

m
m

Site Elevation:

Outdoor

Hertz

ASD power (1.3.e, 2.2.1. Purchaser to advise details, see Page 2, lines 7 through 11)

Other:

Nonclassified

m
m

22

26

Phase

DIRECT COUPLED

21

m
m

m
Class

18

25

m
m

Indoor

HORIZONTAL

17

24

-25 to +40 C

m
m

13

SINE WAVE POWER

Usual Service Conditions (1.2.a, b, c, d, e, h):

NORTH AMERICAN (i.e., ANSI, NEMA)

RPM (Synchronous)

Volts (2.2.1)

10

16

International (i.e., IEC, ISO)

Terminal box at motor side

C
Details:

Shutdown

In the Stator RTD T Box


C

BY
1

OF

BY MANUFACTURER OR
PURCHASER (w or u)

MOTOR BASIC DATA


NORTH AMERICAN (i.e., ANSI, NEMA)

ASD power (1.3.e, 2.2.1. Purchaser to advise details, see Page 2, lines 7 through 11)

Other:

Other:

Pressure guage

Cable Entry:

kW

Volts

ACCESSORIES:

kW

Conduit Head at Bearing

tg

JOB NO.

INDUCTION MOTOR
API 547 1st Edition -- DATA SHEETS
METRIC UNITS

ITEM / TAG NO.

PURCHASE ORDER NO.


REQ. / SPEC. NO.
REVISION NO.

DATE
PAGE

NOTE:
(Excel code)

TO BE COMPLETED BY PURCHASER
(m or l)

BY MANUFACTURER
WITH PROPOSAL (o or n)

BY MANUFACTURER
AFTER ORDER (s or q)

BY MANUFACTU
PURCHASER (w

MISCELLANEOUS:
2

Auxillary nameplate(s) with purchaser information (2.4.11.4):

3
4

Details:
Additional Information:

5
SPECIAL CONDITIONS:
6
7
8
9
10
11

Adjustable Speed Drive Operation (1.3.e, 2.2.1):

m
m
m
m

ASD only

ASD with DOL Start

Bypass @ Utility Frequency

Variable Torque Speed Range:

Min Speed

RPM

Max. Speed

RPM

Constant Torque Speed Range:

Min Speed

RPM

Nm

Max. Speed

RPM

Constant Power Speed Range:

Min Speed

RPM

Max. Speed

RPM

Other Unusual Service Conditions (1.3):

12
DRIVEN EQUIPMENT INFORMATION
13

Driven Equipment:

14

Type of Load:

15

Total Driven-equipment GD2 (2.2.2.5)

16

Rotation Viewed from Opposite Drive End of Motor:

17

Coupling (2.4.9.2):

18

Supplied By:

19

Mounted By:

20

Tag No.

Centrifugal Compressor

Description

Pump

Fan

Type/Model No.
RPM

kg-m2 at

Type

Location

Manufacturer:

Load Speed-torque Curve No. (2.2.2.5)

Clockwise

Counterclockwise

Mfr.

m
m

Motor Mfr
Motor Mfr

m
m

Driven Equipment Mfr


Driven Equipment Mfr

Bi-directional
Type/Model

m
m

Purchaser
Purchaser

m
m

Others
Others

Other:
ANALYSIS, SHOP INSPECTION, AND TESTS

21

Routine Test (4.1.2)

22

No load current

23

Locked rotor current

24

High-potential test (stator, heaters, RTDs)

25

Insulation resistance test

26

Stator resistance

27

Vibration measurement

28

Bearing insulation test

29

Bearing temperature rise

30

Stator Surge Test (4.1.4)

31

Special Tests (per API 541 as noted)

32

Complete Test (541 Para 4.3.5.1)

33

Unbalance Response (541 Para 4.3.5.3)

34

Rated Rotor Temperature Vibration Test (541 Para 4.3.5.2)

35

Sealed Winding Conformance Test (541 Para 4.3.4.4)

36

Other

37

Other

Required

Observed

m
m
m
m
m
m
m
m
m

m
m
m
m
m
m
m
m
m

m
m
m
m
m
m

m
m
m
m
m
m

BY
2

OF

BY MANUFACTURER OR
PURCHASER (w or u)

MISCELLANEOUS:

SPECIAL CONDITIONS:

RPM

Nm

RPM

Nm

RPM

HP

VEN EQUIPMENT INFORMATION

RPM

Bi-directional

IS, SHOP INSPECTION, AND TESTS


Witnessed

m
m
m
m
m
m
m
m
m
m
m
m
m
m
m

JOB NO.

INDUCTION MOTOR
API 547 1st Edition -- DATA SHEETS
METRIC UNITS

ITEM / TAG NO.

PURCHASE ORDER NO.


REQ. / SPEC. NO.
REVISION NO.

DATE
PAGE

NOTE:
(Excel code)

TO BE COMPLETED BY PURCHASER
(m or l)

BY MANUFACTURER
WITH PROPOSAL (o or n)

BY MANUFACTURER
AFTER ORDER (s or q)

BY MANUFACTU
PURCHASER (w

MOTOR DATA
2

Manufacturer

Type/Model No.

Qty.

Service Factor

Full-load Speed

Locked-rotor Torque (LRT)

Load Point

Efficiency

kW
1.

###
###

RPM (Syn.)
Insulation Class

RPM

Poles

CLASS F

Volts

Temperature Rise

Full-load Torque (FLT)


% FLT

50%

Nm

100%

CLASS B

% FLT

Other:

Breakdown Torque (BDT)

Guar. Efficiency at

Power Factor

Current

Amps

Amps

Amps

Amps

11

Speed-torque Curve No.

12

Voltage Magnitude

13

Locked-rotor Current

Amps

Amps

Locked-rotor PF

14

Locked-rotor Withstand Time, Cold

Sec.

Sec.

Sound Pressure Level (2.1.2)

15

Locked-rotor Withstand Time, Rated Temp

Sec.

Sec.

16

Mass

17

Other:

Net

Speed-current Curve No.

kg

Stator

19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43

Test Method:

Speed-power Factor Curve No.

Other:

kg

COMMENTS
18

Enclosure

10

100%

Rotor GD2

Pull-up Torque (PUT)

75%

Frame Size/Designation

Rotor

kg

Shipping

BY
3

OF

BY MANUFACTURER OR
PURCHASER (w or u)

MOTOR DATA

Phase

Hz

Enclosure
kg-m2
% FLT

% Load =

dBA @ 1 m, no-load

kg

COMMENTS

Anda mungkin juga menyukai