Version 2012.1
PM
PetroMod
Release Notes
Copyright Notice
Copyright 2012 Schlumberger. All rights reserved.
No part of this document may be reproduced, stored in a retrieval system, or translated in
any form or by any means, electronic or mechanical, including photocopying and
recording, without the prior written permission of Schlumberger Information Solutions,
5599 San Felipe, Suite 100, Houston, TX 77056-2722.
Disclaimer
*Mark of Schlumberger. Certain other products and product names are trademarks or
registered trademarks of their respective companies or organizations.
PetroMod 2012.1
Schlumberger Public
Trademark Information
Contents
About PetroMod ....................................................................................................... 5
New in PetroMod 2012.1 ......................................................................................... 7
PetroMod-LSF (Load Sharing Facility) Integration Kit ......................................... 7
Simulation Cluster Manager (SCM) ...................................................................... 7
PetroMod Command Menu ................................................................................... 7
PetroMod 1D......................................................................................................... 8
PetroBuilder 3D .................................................................................................. 10
PetroBuilder 2D .................................................................................................. 11
Simulator ............................................................................................................ 12
Kinetics Editor .................................................................................................... 13
Lithology Editor .................................................................................................. 13
Well Editor .......................................................................................................... 13
PetroReport ........................................................................................................ 14
Viewer 2D ........................................................................................................... 15
Viewer 3D ........................................................................................................... 15
Bug Fixes ............................................................................................................... 17
Known Issues ........................................................................................................ 19
All Modules ......................................................................................................... 19
PetroMod 1D....................................................................................................... 19
PetroBuilder 2D .................................................................................................. 20
PetroBuilder 3D .................................................................................................. 22
Viewer 2D ........................................................................................................... 23
Viewer 3D ........................................................................................................... 24
Simulator ............................................................................................................ 25
PetroCharge Express .......................................................................................... 27
PetroReport ........................................................................................................ 27
Release Notes
Schlumberger Public
Schlumberger Public
PetroMod 2012.1
About PetroMod
PetroMod* petroleum systems modeling software combines seismic, well, and geological
information to model the evolution of a sedimentary basin. PetroMod software will predict if,
and how, a reservoir has been charged with hydrocarbons, including the source and timing of
hydrocarbon generation, migration routes, quantities, and hydrocarbon type in the subsurface
or at surface conditions.
PetroMod oil and gas migration modeling technology is the most advanced commercially
available tool and the only commercial system with fully PVT controlled modeling of ncomponent/3-phase relationships during the entire migration process. Multiple simulation
methods, i.e., Darcy, flow path (ray tracing), invasion percolation (IP), and the PetroMod
hybrid Darcy/flow path/IP simulator, can be used with the same data models. The 2D and 3D
migration modeling technology uses flash calculations throughout the entire model and its
geologic history. This delivers an improved understanding and prediction of petroleum
properties and oil versus gas probability assessments.
Release Notes
Schlumberger Public
PetroMod 2012.1 combines a state-of-the-art user interface and high simulation performance
that enables the user to perform sophisticated analyses of the dynamic temperature, pressure
and migration history of complex geologic systems in a fast and intuitive, process-focused
workflow. The unification of the 2D and 3D model builder and new viewer capabilities allow a
fast switch between 2D and 3D model setup and analysis which saves time and costs.
PetroMod 2012.1
Schlumberger Public
PetroMod documentation and installer can be downloaded from the Software Download
Center at:
(follow links for Geology & Geophysics
and PetroMod).
Simulation Cluster Manager (SCM) has been jointly developed by Schlumberger and Platform
Computing. Using Schlumberger software with SCM has the following advantages:
SCM provides easy set up of high-performance clusters. It comes complete with pre-
configured versions of the Platform LSF (Load Share Facility), Platform HPC Web Portal and
Platform Cluster Manager as well as the Schlumberger PetroMod, ECLIPSE and INTERSECT
simulator software (depending on which licenses you purchase).
SCM simplifies and optimizes the throughput of multiple simulation jobs in cluster
environments. Before starting a job, SCM checks for available Schlumberger licenses and
hardware resources and schedules the jobs accordingly.
SCM provides a unified Web portal that makes it easy to submit, monitor and manage jobs
from any machine with a Web browser (workstation, PC, laptop, or mobile device).
SCM is not delivered as part of PetroMod. For more information on SCM, please contact your
Schlumberger representative.
Release Notes
Schlumberger Public
and migration in a geologic time proportional recording. The Video Producer is also
integrated into Viewer 3D.
Unit Settings
The Default Manager is now called Unit Settings (Tools > Unit Settings).
PetroMod 1D
Output Ages Table
An Output Ages table has been added to the Tools folder on the Input pane. The table
shows all the ages that will be used by the Simulator to generate the output model.
Additional output ages can be added to the table.
Thrusting Tool
A thrusting tool has been added to the Tools folder on the Input pane. Use this tool to
thrust layers into a model from an adjacent geological position.
Schlumberger Public
Multi-Model Simulation
It is now possible to simulate multiple models one after the other. Select the models on the
Model pane and click the Run button on the Toolbar. The selected models are simulated
one after the other.
PetroMod 2012.1
Simulator Options
By default the Use Previous Run option is now turned off.
The following new features have been implemented in both PetroBuilder 3D and PetroBuilder
2D.
Facies
Facies handling has been significantly improved and includes the following new features:
Simplified renaming and sorting of facies and facies maps: New buttons to simplify
these facies operations have been added to the Facies Definition table, Facies
Assignment table and the Context menu of the Facies Maps folder on the Model
pane.
Create Facies and Maps process: This process has been redesigned and now offers
more options.
Convert ID Maps to Facies Maps: This process now handles multiple ID maps and
automatically generates ranges.
Assign Facies across TecLink Model: This new process simplifies facies assignment in
TecLink models.
Substitute Facies in Area: This process contains two new options for creating the
piercing sub facies and automatically adding them to the Facies Piercing table.
Release Notes
Schlumberger Public
1D Extraction
The 1D Extraction function contains a new check box called Remove redundant
sublayers. When each sublayer in a layer contains the same facies, the sublayers are
considered redundant. Tick this box to extract only the layer, not the redundant sublayers.
Schlumberger Public
Model View
Depth View has been renamed to Model View.
PetroBuilder 3D
The following new features have been implemented in PetroBuilder 3D only.
PetroMod 2012.1
10
Export Faults
Maps in the Fault Workshop and triangle maps can now be exported.
A new selection tool for selecting the intersections of two maps is available on the Map View
Toolbar
Clipping in 3D View
The Clipping function on the 3D View Lower Toolbar now enables you to clip the model in
all directions
. Click the down arrow and select a clipping direction. A dialog box will
open. Use the slide bar or key in a value to set the clipping distance. Add another clipping in a
different direction if required. A clipping remains active until you click select the clipping
direction again to toggle it off.
PetroBuilder 2D
The following new features have been implemented in PetroBuilder 2D only.
11
Release Notes
Schlumberger Public
Select Intersections
Diagonal Faults
Faults are now calculated diagonally across grid cells for a more accurate representation of
faults and improved charge predictions.
A new button for editing block boundaries has been added to the 2D View Toolbar
This functionality was previously accessible from the Edit Pre-grid Lines button.
Simulator
Performance
Diagonal Faults
Faults are now calculated diagonally across grid cells in 2D models for a more accurate
representation of faults and improved charge predictions.
PetroMod 2012.1
12
Schlumberger Public
layers (e.g. sandstone layers) has been significantly improved. By using the special option
Oprm 1, you can simulate the model using the PetroMod 2011.1 pressure solution.
Kinetics Editor
Compare Kinetic Reactions
Curves (kinetics) can now be added to graphs in the Test tab. This enables kinetics to be
graphically compared. Right-click on the graph and select Curves > Add curve
SARA Kinetics
New kinetics in accordance with the SARA scheme from the PEER Institute are available in the
Kinetics Editor. The use of these kinetics is license controlled. Please contact the PetroMod
support team to obtain the respective license.
There are TI, TII and TII SARA kinetics. The kinetics have the prefix Tang(2011)_SARA_.
SARA kinetics should only be used with secondary cracking. Secondary cracking is a vital
CO2, H2S, and asphaltenes are retained by default in source rocks with high adsorption
factors.
PVT calibration was performed by adjusting C6-C14, C15+Sat, C15+Aro, NSO component
, Se).
Lithology Editor
Calculate seal properties
The calculate seal properties tool in the Seal Properties tab now enables users to
calculate either capillary entry pressure or column height.
Well Editor
Well Completion
A new table in the Well Editor enables users to enter information on well completion.
13
Release Notes
Schlumberger Public
A Pepper (1991) type component adsorption model is used for HC, CO2 and H2S source rock
PetroReport
New Source Statistics Pane
The new Source Statistics pane shows the amount of hydrocarbons that were generated,
expelled or accumulated in the selected source rocks at any given paleo time.
Multiple Models
It is now possible to view data from multiple models at the same time in the Events pane.
Unit Settings
The Unit Settings function has been added to the Options menu on the Menu bar. Use
this function to change the unit settings.
PetroMod 2012.1
14
Schlumberger Public
Note: the known issue is documented in the Addendum to the PetroMod Well Editor User
Guide that can be downloaded from the PetroMod documentation page (PetroMod 2011) on
the Schlumberger Support Portal.
Test Mode
A new function called Test has been added to the Options menu on the Menu bar. Select
the function to enter test mode. In test mode PetroReport checks whether the values in the
Generation and Balance columns have been calculated correctly. Incorrect values are shown
as nan. Click the Test function again to exit test mode.
Show oil and gas in different volume units on the Events pane
A new scroll box on the Events pane enables users to select the volume units for oil
components. Gas components continue to be shown according to the units that are set in the
Options pane. This enables users to show gas and oil components in different units.
GOR
The GOR can be shown in the Events pane.
Viewer 2D
Faults are now calculated and shown diagonally across grid cells in 2D models for a more
accurate representation of faults and improved charge predictions.
Export Data
This is a new function for exporting data to ASCII files. Users define which overlay
information is exported for which layers at which events. Open the function from the File
menu: File > Export Data.
Viewer 3D
Export/Import Polygons and Drainage Areas
It is possible to export polygons, line maps and drainage areas from Viewer 3D.
Imported line maps can be converted to polygons again to be used in PetroReport.
Video Producer
The new Video Producer enables users to generate animated videos of the burial history of
3D models. Use effects such as rotation and zooming to create videos containing all overlays
and migration in a geologic time proportional recording.
15
Release Notes
Schlumberger Public
Diagonal Faults
Labels
The Labels dialog box contains a new option called Improved Visibility. Use this option to
improve the visibility of a label that is partially or fully obscured, e.g. by the underlying or
overlying layer. Only use it when necessary. Do not use it for all labels. The more labels with
improved visibility, the slower the performance of Viewer 3D.
PetroMod 2012.1
16
Bug Fixes
PetroMod 2012.1 contains almost 1000 bug fixes and enhancements. The following lists the
bug fixes that we think will be of most interest to users.
Module
All Modules
Issue ID
N/A
Description
Users can now create color schemes with fixed ranges.
PetroMod
Command Menu
2605739
2542669
2558583
PetroMod 1D
2585676
2584042
PetroBuilder 2D
2578599
N/A
2583275
2588181
PetroBuilder 3D
2577228
2580342
2580350
2632045
2614922
N/A
2553682
Lithology Editor
2538221
2583437
17
Release Notes
Schlumberger Public
2623136
Module
Simulator
Issue ID
Description
2573587
2596739
2605366
2633514
2588501
2590379
2575471
2584070
2575689
N/A
2571273
2613784
2584070
Viewer 2D
2627596
2605175
Well Editor
N/A
PetroMod 2012.1
18
Schlumberger Public
Viewer 3D
Known Issues
All Modules
Issue ID 2541011: GUI does not update correctly under Windows Vista and
Windows 7
When running PetroMod on Windows Vista or Windows 7 with a non-Aero theme, the GUI
often fails to update correctly.
Workaround:
Change the theme to Aero:
1. Right-click on the Desktop and select Personalize. The Personalization dialog will open.
2. Select Window Color and Appearance. The Appearance Settings dialog will open.
3. Select Windows Aero and click OK.
Workaround:
When saving a session, add .xml to the file name.
PetroMod 1D
Issue ID 2640382: SWIT curve does not update after changing values in AutoSWIT
This issue concerns the AutoSWIT tool in the Boundary Conditions dialog. When you
change the parameters in the AutoSWIT tool, the corresponding table in the boundary
conditions dialog updates, but the plot does not. This is important because the values in
the plot are used by the Simulator.
Workaround:
After changing values in the AutoSWIT tool, toggle the AutoSWIT tool off and on (turn the
check box off/on) to update the plot.
Issue ID 2615160: Legend does not show overlay name
The legend on 1D plots does not show the full name of the overlay. For example,
TR_Pepper&Corvi TIIH and TR_Pepper&Corvi TII both appear as Transformation Ratio
[%] in the legend.
19
Release Notes
Schlumberger Public
PetroBuilder 2D
Issue ID 2562161: Import Wizard cannot import grid-based data as maps
Workaround:
1 Create a new map in the appropriate folder on the Model pane.
2 Double-click the map to open the Map Edit dialog.
3 Copy data from another model or spreadsheet and paste it into the table in the Map Edit
dialog.
Issue ID 2579777: Create Heatflow Trend from McKenzie Model PWD Trend is
always used instead of Water Depth / Paleo Depth table
This process always uses the Paleo Water Depth Trend that is selected in the Crustal Model
tab. If you do not specify a trend, the tool uses the Default_PWD trend.
PetroMod 2012.1
20
Schlumberger Public
The Default_PWD trend is used even if the model has been built using values in the Water
Depth / Paleo Depth table on the Model pane (instead of a trend).
Workaround:
1 Open the Trend Editor and create a new PWD trend. Leave it blank for now.
2 Extract a 1D model at the same location as your PWD trend.
3 Open PetroMod 1D and open the 1D model you extracted in step1. Open the Boundary
Conditions dialog and copy the PWD trend to the new PWD trend in the PetroBuilder 2D
Trend Editor.
3 You can now use the new trend in the Create Heatflow Trend from McKenzie Model
process.
Issue ID 2543069: Do not change the order of maps generated by Create Heatflow
Maps from McKenzie Crustal Model
The Create Heatflow Maps from McKenzie Crustal Model process generates a number of
maps that are listed in different folders on the Model pane. The order in which these maps
are listed in the folders affects the curves in the 1D plots. Do not change the order of the
maps in these folders! Doing so will result in incorrect 1D curves.
21
Release Notes
Schlumberger Public
PetroBuilder 3D
Issue ID 2642134: Substitute Facies in Volume process
The Substitute Facies in Volume process only works when the depth maps and layers are
turned on. Before using this process, tick the check boxes next to the Depth Maps and
Layers folders on the Model pane.
Issue ID N/A: Several small bugs in McKenzie Crustal Heat Flow process
The Create Heatflow Maps from McKenzie Crustal Model process contains several small
bugs that will be fixed in the next release.
Issue ID 2579777: Create Heatflow Trend from McKenzie Model Default PWD
Trend
See the description of the same known issue in PetroBuilder 2D.
Issue ID 2543069: Order of maps generated by Create Heatflow Maps from
McKenzie Crustal Model affects the appearance of curves.
See the description of the same known issue in PetroBuilder 2D.
Issue ID 2492780: Imported facies maps must have same origin as model
This issue occurs when the origin of an imported IRAP Ascii facies map is different from the
origin of your model. When the map is converted, PetroBuilder re-grids the map from draft
resolution to model resolution. The re-gridding process grids the facies map to the origin of
the model, resulting in the loss of the defined area of the imported map.
Issue ID 2539018: Default Layout function
After re-arranging several windows, the Default Layout function does not always restore
the layout as expected.
Issue ID 2542275: Extraction and injection points are not set correctly in Map
View.
When the user tries to set an extraction point or injection point in Map View, the points are
either set in the wrong place or are not visible.
Workaround:
Set the points in 3D View.
Issue ID 2523052: No session control
There is no session control in PetroBuilder 3D, i.e. it is not possible to save sessions and
load sessions.
Issue ID N/A: Save as function does not save simulator settings
See the description of the same known issue in PetroBuilder 2D.
PetroMod 2012.1
22
Schlumberger Public
Issue ID 2632561: Fault property type FCP/Perm not calculated during conversion
from PetroMod Version 11
See the description of the same known issue in PetroBuilder 2D.
Viewer 2D
Issue ID 2640748: Wrong CGR value in Accumulation Info box
The CGR value in the Accumulation Info box is too low by a factor of 5.614.
Issue ID N/A: Gaps in 2D Models in Viewer 2D
Gaps can appear when viewing 2D models in Viewer 2D. This is a purely visual problem
due to current limitations in Viewer 2D. The simulated model itself is complete and does
not have any gaps. The gaps occur at locations where the cross-section turns through an
angle and the turning point does not lie on a grid point.
Schlumberger Public
2D View
3D View
The diagram on the right is from Viewer 2D looking down on the cross section of a 2D
model (in the 3D View tab). The red rectangles mark the locations where the cross-section
turns through an angle. The green line is a pre-grid horizon and represents the crosssection as entered by the user in PetroBuilder 2D. The black line is the cross-section as
represented in Viewer 2D. You can see that the cross section in Viewer 2D does not turn at
the same location as the pre-grid horizon. This is because the turning point of the pre-grid
horizon does not lie on a grid point. Viewer 2D shifts the turning point to the adjacent grid
point which results in gaps at these locations. As mentioned above, this a visualization
problem only, there are no gaps in the simulated model.
Workaround:
Add grid points at each point where the cross-section turns through an angle. The easiest
way is to insert a grid point for each cross-section point:
1) Open PetroBuilder 2D and load your model.
23
Release Notes
2) Go to the Processes pane, expand the Grid folder and double-click on Modify
Grid Points.
3) Right-click anywhere in the Grid Points table and select Insert Points from Cross
Section. There will now be a grid point for each cross-section point.
Schlumberger Public
Viewer 3D
Issue ID 2519190: TecLink models not supported in Viewer 3D
Some TecLink models are not properly displayed in Viewer 3D and some cannot be opened
in Viewer 3D at all.
Issue ID 2515868: Selecting percolation accumulations
Move the cursor near a percolation accumulation in 3D View and click with the left mouse
button. The percolation is selected even though the cursor is not on the accumulation.
Issue ID N/A: Filter accumulations according to Flash calculations
The option for filtering accumulations according to the results of Flash calculations does not
function correctly.
Issue ID 2644828: Viewer 3D crashes when opening a partially simulated model
When you open a model that was not completely simulated (e.g. when the Simulator stops
due to an error in the input data), Viewer 3D crashes.
PetroMod 2012.1
24
Simulator
Issue ID 2587183: Hydrocarbons inside intrusion body
Hydrocarbon accumulations remain inside the intrusion body and are not vaporized as they
should be.
Issue ID 2604436: Migration at block boundaries in TecLink models
In a TecLink model, when there is an open fault at a block boundary and a reservoir rock
on the left and right of the boundary, the hydrocarbons pass through the fault.
Issue ID 2606617: Fault Saturation overlay is not realistic
The Fault Saturation overlay does not show realistic results in some models.
Issue ID 2620221: PetroReport shows incorrect values for TecLink models
Although this issue is visible in PetroReport, the cause of the issue is in the Simulator which
generates incorrect values.
Workaround:
Use a serial simulation or contact PetroMod support for a parallel workaround.
Issue ID 2627038: Faults are not calculated when periods are listed from latest to
earliest in TecLink models
When faults with multiple time periods are included in TecLink models, the results depend
upon the order of the fault periods in the Fault Property Definition table. For each fault, the
periods should be listed from earliest to latest; otherwise the fault may be incorrectly
deactivated during many paleo times.
Issue ID 2629978: Parallel simulation on Linux
Command line parameters containing spaces (e.g. when the path name contains spaces),
prevent models from being simulated on parallel processors.
Issue ID 2633585: IP migration does not generate gas hydrate masses
When models are simulated using Invasion Percolation, migration pathways cross the gas
hydrate stability zone without generating gas hydrates.
Issue ID 2638589: 2D diagonal faults on parallel processors
Simulating 2D diagonal faults using the Hybrid or Darcy migration method on parallel
processors causes errors. When this occurs, the Simulator stops with an error message.
25
Release Notes
Schlumberger Public
Workaround:
Simulate the model on a single processor.
Or
Use the special option Odfg 0 to switch off diagonal faults.
Issue ID 2626329: Incorrect accumulation column heights
When a closed or partially open fault (FCP fault) runs through a flowpath layer, the
accumulations on either side of the fault might have different column heights. This issue
can occur for models simulated using either the Hybrid or Darcy migration method.
Issue ID 2634426: Crustal Layer model does not take half-depth value into
account
The (radiogenic heat) half depth value of a lithology (if non-zero) specifies the rate with
which the radiogenic heat production in a layer of that lithology should decrease with
depth. This value can be set in the Lithology Editor (Radiogenic Heat tab). The half depth
value applies to crustal layer models only. The crustal layer model calculation in the
Simulator does not consider this half depth value. Consequently, the overall radiogenic
heat production is higher than it should be.
PetroMod 2012.1
26
Schlumberger Public
Issue ID N/A: Convection does not work with locally refined volumetric faults
For convection through faults, use the Volumetric Elements option in the Simulator
interface (PetroFlow > Fault Method).
Accumulations
This issue occurs when a model is simulated using the following Simulator settings:
Fault method: Volumetric faults
Migration method: Hybrid.
PetroCharge Express
Issue ID N/A: Application remains in waiting mode for a long time after opening a
file
When loading files from a network drive, PetroCharge Express often does not respond for
a long time.
Workaround:
Use Files > Open Project (Quick mode).
PetroReport
Issue ID 2644828: PetroReport crashes when opening a partially simulated model
When you open a model that was not completely simulated (e.g. when the Simulator
stops due to an error in the input data), PetroReport crashes.
27
Release Notes
Schlumberger Public
The image above shows an open volumetric fault running underneath a reservoir layer
(yellow). The reservoir contains an oil and a gas accumulation. The hydrocarbons should have
drained out of the reservoir through the open fault.
Lithology Editor
Issue ID N/A: Mixing lithologies
Well Editor
Workaround:
When importing deviation data that is not in meters, do not use the import functions in
Well Editor. Instead, copy and paste the data into the Deviation table.
Issue ID 2640427: Importing LAS files
If your LAS file contains depth values in meters, you can ignore this issue.
If your LAS file contains depth values in a unit other than meters (e.g. feet), the depth
values will be imported incorrectly. Use the workaround described below.
Workaround:
Before importing the data, check the header of the LAS file. The keyword after Depth in
the header indicates the unit in which the depth information is stored. Depending on the
keyword, perform one of the following:
A - If you are importing depth data in feet and the keyword contains a capital F:
1 Import the LAS file. The log curves will be imported but they will have the wrong
depth values.
2 Make sure the Display Unit in Well Editor is set to ft (File > Unit Settings)
3 For each imported log curve:
i. Select the log curve on the Well Browser
PetroMod 2012.1
28
Schlumberger Public
ii. In the Table View, select all the imported depth values (Measured Depth
column).
iii. Right-click > Convert to [ft] from [meter]. The imported depth data will now
have the correct values.
B - If you are importing depth data in feet and the keyword does NOT contain a capital
F:
1 Import the LAS file. The log curves will be imported but they will have the wrong
depth values
2 Make sure the Display Unit in Well Editor is set to meter (File > Unit Settings)
3 For each imported log curve:
i. Select the log curve on the Well Browser
ii. In the Table View, select all the imported depth values (Measured Depth
column).
iii. Right-click > Convert to [meter] from [feet]
C - If you are importing depth data in any other unit and the keyword does NOT contain a
capital F:
Proceed in the same way as in B. Replace feet in Step 3 iii and ft in Step 4 with
your unit.
29
Release Notes
Schlumberger Public
4 You can now change the Display Unit to ft (File > Unit Settings)
System Requirements
Hardware requirements
For workstations (e.g. Dell T7500)
Processor
Memory
Disk space
Graphics
Network card
Software requirements
Microsoft Vista
Microsoft Windows 7 (recommended)
RedHat Enterprise Linux 5.3 (recommended)
Microsoft.NET Framework
64-bit
64-bit
64 bit
2.0
IMPORTANT for Windows users: Several visualization issues in PetroMod 2011 were due
to the use of older graphic drivers. Only the Nvidia driver versions 295.73 and
later provide built-in support for PetroMod. We strongly recommend installing these
drivers to ensure optimal visualization and avoid visualization problems.
PetroMod 2012.1
30
Schlumberger Public
Processor
Memory
Disk space
Graphics
Warning for RHEL 5 users: Due to known issues concerning the instability of OpenGL
graphics, PetroMod only supports local rendering on 3D graphic cards with stable
graphic drivers. Rendering via a network could cause stability issues. In particular, we
observed problems with the Mesa OpenGL package that is delivered with RHEL5 and
works as a fall-back when no other driver is installed.
Note for Microsoft Windows users: When running PetroMod on Windows Vista or
Windows 7 with a non-Aero theme, the GUI often fails to update correctly. Change the
theme to Aero to resolve this issue (see also Issue ID 2541011 in the Known Issues
section).
Note for Microsoft Windows 7 and RedHat Enterprise Linux 5.3 users: We
recommend installing the latest graphics drivers available from Nvidia or ATI to avoid
OpenGL graphic display errors. In most cases the driver version that comes with the
operating system is quite old. Moreover, generic drives are used when the graphics
hardware is not recognized correctly during installation of the operating system. These
drivers only support basic functionality and do not offer the OpenGL features required
by PetroMod. Please be aware that most onboard graphics hardware does not support
OpenGL at all. A dedicated graphics card is required for PetroMod.
31
Release Notes
Schlumberger Public
Recommended: If your notebook has an integrated graphic unit in the processor (GPU), as
is the case with the Intel Sandy Bridge processor, we recommend disabling the GPU in
the BIOS. This will help you avoid performance problems and visualization errors.
Licensing
Licenses are required to access PetroMod. Certain functionalities or modules are only available
with the respective licenses. Contact your Schlumberger SIS Customer Support representative
to obtain the necessary licenses.
Maintenance contracts are usually yearly contracts, renewed at any time during the year. Prior
to 2012.1, PetroMod licenses allowed you to step up to a new PetroMod version based on the
PetroMod license expiration date without having a valid maintenance contract. Beginning with
2012.1, upgrades are based on your maintenance contract expiration date. This is how you
read the new licensing format:
FEATURE petrobuilder3D slbsls <yyyy.mm> <dd-mmm-yyyy> <#>
Where
<yyyy.mm> is the maintenance expiration year and month
<dd-mmm-yyyy> is the license expiration day, month, year
<#> is the number of licenses
Module-based licensing
PetroMod 2012 uses a module-based licensing concept. The benefits are:
PetroMod 2012.1
32
Schlumberger Public
Maintenance renewal is required to run any PetroMod version released after your
maintenance expiration date. You will be automatically contacted by Schlumberger
Information Systems before your maintenance expires.
PetroMod 2D
PetroMod 3D
PetroMod 1D
2D Model Builder
3D Model Builder
PM1D PetroRisk
2D Pressure-Temperature Simulation
3D Pressure-Temperature Simulation
2D Kinetics Models
3D Kinetics Models
PM2D 2-Component
PM3D 2-Component
PM2D Multi-Component
PM3D Multi-Component
PM2D Flowpath
PM3D Flowpath
PM2D Hybrid
PM3D Hybrid
2D Add-ons
3D Add-ons
PM2D PetroRisk
PM3D PetroRisk*
PM2D TecLink
PM3D Geomechanics
PM2D Geomechanics
PM3D Biodegradation
PM3D Local Grid Refinement (LGR)
PM3D Crustal Modeling
2D and 3D Add-ons
PM Parallel Processing
PM SARA Kinetics
PM TSR Modeling
33
Release Notes
Schlumberger Public
PetroMod 1D
Support
Support for PetroMod software is supplied by the Schlumberger Customer Care Center. Please
go to the Schlumberger Support Portal at https://support.slb.com and follow the general
PetroMod support procedures.
Supporting Documentation
The following documentation for PetroMod 2012.1 is available on the Schlumberger Support
Portal at http://support.slb.com
PetroMod 2012.1 Installation Guide
PetroMod 2012.1
34
Schlumberger Public